AUTOMATION AND INTEGRATION SOLUTIONS
for Electric Power Systems
Making Electric Power Safer, More Reliable, and More Economical
IED Integration
Event Monitoring, Collection, and Analysis
Local HMI and Visualization
Cybersecurity
RTU Replacement
Distribution Automation
Remedial Action Schemes
SCADA
Asset Optimization
-
7/29/2019 AI Solutions
2/162
Schweitzer Engineering Laboratories has delivered
solutions for over 25 years that make electric power
safer, more reliable, and more economical.
SEL invented the worlds rst digital distance relay
in 1984, revolutionizing fault location, event analysis,
and protection. In 1999, south of Orlando, Florida,SEL implemented smart grid projects in the Interna-
tional Drive power grid to automatically sectionalize a
faulted line and recongure the grid to restore service
to unfaulted sectionsall within six cycles.
Leading in wide-area monitoring, protection, control,
and analysis, SEL has installed over 31,000 SEL
synchrophasor phasor-measurement-ready relays
around the world.
We offer engineering services, providing professional
consulting and turnkey solutions for utility, industrial,and commercial markets worldwide.
We also offer specialized training through SEL Univer-
sity courses. Visit www.selinc.com/selu for more
information and to register for courses.
SEL designs and manufactures products for the
worlds most challenging production environments
to exceed all industry standards for temperature,
shock, and electric stress. SEL products operate in a
temperature range of40 to +85C (40 to +185F).
They withstand electrostatic shock up to 15 kV and arevibration/shock resistant up to 15 g.
We rigorously test our equipment in real-world condi-
tions, producing products that lead the industry in
their ability to withstand harsh substation environ-
ments. Manufactured in Pullman, Washington, USA,
SEL products exceed industry standards and come
with a ten-year, no-questions-asked, worldwide
warranty.
Through a relentless focus on continual improvement,
SEL achieves ever-increasing levels of quality, delivery,
and service performance. Since 2004, in indepen-
dent studies conducted by Newton-Evans Research
Company, Inc., electric utilities have ranked SEL the
North American leader in all categories surveyed,
including technology, price, features, service, and
security.
About SEL Rel iab i l i ty
Power Plant
Factory
Distribution SubstationControl Enclosure
Motor-Operated Air BreakSwitch Control
UndergroundFaulted Circuit
Indicators
Overhead
Faulted CircuitIndicators
Automated Pad-MountedSwitchgear
Feeder Monitoring andCapacitor Bank Control
Feeder Monitoring
Renewable Energies
RecloserControl
Advanced MeteringSolutions
Advanced MeteringSolutions
Voltage RegulationControl
Single-Phase RecloserMonitoring
Transmission Substation
Control Enclosure
From the generating station to the end of a distrib ution line, SEL solutions make the electric p ower grid smarter by providing protection, communications, sensing,monitoring, security, and control.
-
7/29/2019 AI Solutions
3/163
Today, SEL offers robust automation and integration
solutions for your applications and is committed to
leading with the best, most economical solutions.
We offer technologies, products, systems, and services
that address the entire application spectrum, from
communicating with a single relay to integratingand automating the metering, control, reporting, and
protection for a large system. In electrical substations,
commercial sites, and generating, manufacturing, and
processing plants, apply SEL microprocessor-based
relays to protect the electrical system. Apply SEL
networking, control, and communications solutions to
integrate devices for data acquisition plus remote and
local control.
SEL relays, information processors, and systems
support many architectures. SEL information proces-
sors include real-time automation controllers (RTACs),
communications processors, and tough computers
with appropriate software.
Choose tough SEL computing and networking prod-
ucts that are far more reliable and robust than ofce or
industrial computer equipment and ideal for protocol
conversion, local human-machine interfaces (HMIs),
event report collection, data concentration, and more.
Many SEL relays include local, remote, and latched
control switches and display points. With these
features, you can replace or eliminate many external
devices and associated panels, documentation, wiring,commissioning, testing, and maintenance. You benet
from reduced total cost, improved system reliability,
and state-of-the-art protection, monitoring, and
control.
Information processors support external communica-
tions links, including the public switched telephone
network for engineering access or dial-out alerts,
private line connections to your SCADA system,
and wide-area networks (WANs). Many SEL relays
and controllers have integral protocols and ports for
connection to networks. The SEL ICON provides the
ber-optic communications backbone.
SEL products and services are components of complete
SEL solutions for instrumentation, protection,
reporting, monitoring, local and remote control, and
automation.
Automat ion and Integrat ion Overview
Block diagram of typical utility communications infrastructure.
Satellite-Synchronized Clock
Satellite-Synchronized Clock
SEL-2407
Relays, Controllers,and Other IEDs
Event Messenger
Dial-UpVoice Link
Dial-UpData Link
SerialSCADA Link
Serial SCADA Link
EncryptData
Encrypt Data
Modem
Relays andOther IEDs
EncryptData
Station LAN
Other IED
SEL-2407
Relay
Relay
Interleaved ASCIIand Binary Data forMost SEL Products,
Noninterleaved for Others
SEL-3010
ProgrammableAutomation Controller
Remote I/OModule
Remote I/OModule
Other IED
Relay
SEL-2515
SEL-2516
SEL-2411
Human-Machine
Interface
Relays, Controllers,and Other IEDs
Information Processor
Information ProcessorInformation Processor
Tough Computer
IntegratedCommunicationsOptical Network
IntegratedCommunicationsOptical Network
Security Gateway
Security Gateway
Remote I/OModule
EthernetSwitch
EthernetSwitch
Other IEDSEL-2516
PDC
Annunciator
Port Server
RTU
Relays, Controllers,and Other IEDs
Discrete ProgrammableAutomation Controller
Copper Ethernet
Copper Ethernet
Fiber-OpticEthernet
Copper Ethernet Relay
SEL-2725
SEL-2725
SEL-2440
SEL-3354
SEL-3373
SEL-3620
SEL-3620
SEL-3610
SEL-2533
SEL-551
SEL-751A
SEL-3530
SEL-3530
SEL-3530
SEL-2240
-
7/29/2019 AI Solutions
4/164
SEL information processors enable you to design and
implement both simple and complex intelligent elec-
tronic device (IED) integration solutions. Supported
peer-to-peer technologies include SELs patented
Mirrored Bits communications and IEC 61850.
SEL Informat ion Processors
With protocols, I/O, and easy-to-use interfaces, SEL
information processors like the RTAC offer data
acquisition, control, and automatic notication for
both SEL and non-SEL IEDs.
SELs newest information processor, the SEL-3530
Real-Time Automation Controller (RTAC), is the next
generation in automation control. The RTAC features
secure communications, advanced data concentra-
tion, high-speed logic processing, flexible engineeringaccess, and protocol conversion capabilities between
multiple built-in client/server protocols. The RTAC
also provides the tools necessary to easily integrate
and concentrate information from the wide variety
of microprocessor-based devices found in todays
substations.
SEL University offers WBT 3332
Conguring Logical Expressions Using
the SEL-3332 Intelligent Server and
SEL-3351 System Computing Platform.
IED Integration
SEL-3530
SEL-2725
Five-Port EthernetSwitch
SEL-3354
LocalHMI SEL MirroredBitsRelaysEngineering
Encrypted Link
SEL Switch
GOOSE Messaging
DNP3, Modbus,IEC 61850
EIA-232 Mirrored BitsCommunications Links
Protocol conversion and data concentration with local control.
-
7/29/2019 AI Solutions
5/165
IEC 61850 and GOOSE Messaging
SEL products support IEC 61850 and GOOSE,
allowing you to combine IEC 61850 technology,
Ethernet networking, and SEL high reliability
to perform station computing, automation,
and control. Find out more about IEC 61850and GOOSE messaging solutions, case studies, and technical
papers on the SEL website at www.selinc.com/61850 .
Display and control using operational data in IEC 61850 logical nodesvia LAN for local HMI, and WAN for remote SCADA. Engineers use WANto congure devices and to retrieve and analyze event reports andsequential events records.
Relay 1 sends high-speedGOOSE messages to Relay 2.
SEL-387
Relay 1
Relay 2 sends high-speedGOOSE messages to Relay 1.
Relay 2
SEL-451
Ethernet Switch
SEL-2725
Five-PortEthernetSwitch
Use IEC 61850 GOOSE messages to communicate high-speed information betweenlocal relays or other devices on the local-area network (LAN). Examples includebreaker position, breaker trip, interlocking, and load-shedding commands.
3
1
3
1
52
52
Source #1
Source #2
Recloser
Recloser
Hospital
(critical load)
(up to 20 miles
using SEL-3031)
MIRRORED BITS
Communications
SEL-351R
SEL-351R
MirroredBitscommunications recloser application
SEL Serial Radio
Transceiver
SEL Serial Radio
Transceiver
Fiber-Optic
Audio
Radio
Wave
Available
CommunicationsPaths
SEL-311C SEL-311C
SEL-3031SEL-3031
MirroredBitscommunications transmitted over radio channels.
EngineeringOffice Desktop
PC
ControlCenter SCADAMaster
Wide-Area Network
SEL-
451-4
SEL-311L
SEL-387
SEL-
421
SEL-
487B
SEL-
451
Local HMI
SEL-2411
SEL-710 SEL-751A
SEL-3354
SEL M i r rored B i ts Communicat ions
Mirrored Bits communications is an innovative, low-cost, relay-to-
relay communications technology that exchanges the status of eight
internal logic points called Mirrored Bits, encoded in a digital message,
between two devices. This patented technology opens the door to
numerous integration applications that would otherwise require more
expensive external communications equipment wired through contacts
and control inputs. Integration applications for Mirrored Bits commu-
nications include line protection pilot schemes, remote device controland monitoring, relay cross-tripping, and more.
Apply Mirrored Bits communications over radio channels for direc-
tional comparison protection schemes. This provides fast fault clearing
and preserves transient and voltage stability at very low cost. For
additional information on integrating your applications using
Mirrored Bits, visit www.selinc.com/mirroredbits .
-
7/29/2019 AI Solutions
6/166
In 1984, SEL invented the worlds rst digital distance
relay with a built-in fault locator, revolutionizing fault
nding. Current SEL event reporting technology and
software, such as the ACSELerAtor Analytic Assistant
SEL-5601 Software, makes wide-area monitoring,
collection, analysis, and control of power system datapossible.
Integrated systems with SEL synchrophasors take
event analysis one step further by providing the ability
to monitor power system distur-
bances in real time through angle
measurements, modal analysis, and
out-of-step detection. You can view
time-synchronized events together
using the SEL-5601 Software. SEL
uses the SEL-3378 Synchrophasor
Vector Processor (SVP) to createreal-time, wide-area monitoring,
protection, automation, and control
solutions.
The magnitude of the Northeast
power blackout on August 14, 2003,
could have been prevented, and
the data analyzed in minutes rather
than months, by using an SEL
integrated and synchronized event
monitoring and analysis solution.
Another outage in Florida on February 26, 2008, was
quickly analyzed by engineers using an SEL integrated
and synchronized solution. The engineers then used
their synchronized solution to improve their models
and prevent similar situations in the future. A NERC
press release on the Florida outage stated that synchro-phasors are like the MRI of the bulk power system.
SEL University offers
the following classes
in event monitoring,
collection, and analysis:
WBT 101 Event Report
Analysis Workshop
WBT 102 Event Report
Analysis Workshop for
Distribution Relays
CBT 102 Retrieving Event
Reports for Technicians
CBT 103 Analyzing Event
Reports for Engineers
Line Trip
System Separation
Line Trip and Generation Drop
Seconds
MW
Amplitude = 42.02Damping Ratio = 3.22%Frequency = 0.232 Hz
Amplitude = 1 6.74Damping Ratio = 0.76%Frequency = 0.258 Hz
Amplitude = 32.71Damping Ratio = 8.9%Frequency = 0.263 Hz
SEL-3378SEL-421
300 400 500100 2000
1150
1350
1550
1750
1400
1500
1600
1525
1545
1565
1500t
MW
MW
MW
t t
1550
1600
Negative Damping RatioDamping Ratio < 10% Damping Ratio < 3%
Line tripping, loss of generation, and other system events cause power oscillations. Use theSVP to identify oscillations in the early stages and alert power system operators to potentiallyunstable operating conditions.
Event Monitoring , Co l lect ion, and Ana lys is
-
7/29/2019 AI Solutions
7/167
SEL IEDs and tough computers monitor the status
of communications lines and logic controllers,
summarizing power system data (MW, MVAR,
voltage, and current) and interfacing with settings for
power management and remedial action schemes.
Display one-line diagrams, alarms,communications diagrams, and many other useful
tools with the substation touchscreen.
SEL remote I/O modules and alarm panels
provide quick indication status and alarm
annunciation.
Connect to information processors and IEDs to
gather data, perform operations, and display the
information you want.
Loca l HMI and V isua l izat ion
SEL tough computers support a wide variety of visualizations for local HMI.
-
7/29/2019 AI Solutions
8/168
Implement cybersecurity with substation-hardened
products from SEL. SEL relays and information
processors contain strong electronic access-control
technologies to effectively secure your cyberassets.
The SEL-3620 Ethernet Security Gateway secures
all Ethernet communications between your privatenetworks and interoperates with existing business IT
and control systems over an Internet Protocol Security
(IPsec) virtual private network (VPN). The SEL-3620
protects your private network from malicious trafc
with an integrated rewall and strong authentication
access control.
The SEL-3025 Serial Shield, an EIA-232, bump-in-
the-wire serial cryptographic transceiver, protects
meters, protective relays, programmable logic
controllers (PLCs), remote terminal units (RTUs),
and computers. The SEL-3025 prevents unauthorized
access, control, monitoring, and malicious attacks
by authenticating and optionally encrypting all data
along the communications path.
Our tough computers are also used in security solu-
tions for their inherent authentication, security
management, IPsec IP ltering, encryption, logging,
password protection, and authentication features.
Combine SEL technology with your policies, proce-
dures, and training for a complete solution. For more
information, visit www.selinc.com/cybersecurity .
SEL University offers:
APP 3620 Sensible Cybersecurity
Using the Ethernet Security Gateway
COM 203 SEL Cybersecurity Best
Practices for Critical Infrastructure
Where Is the Network Vulnerable to Intrusion?
SCADA Control Center
Real-Time Protection
Substation orGeneration Facility
Remote Monitoring or Billing
Satellite
Private or PublicTCP/IP Network
Remote Access
SCADA/RemoteAccess
EngineeringAccess
Telecom
NetworkWAN
Public TelephoneNetwork
Wireless
Dedicated Fiber,Wire, or Cable
Internet
SCADA/MeteringCommunications
Cybersecur ity
SEL employs a number of
individuals with professional
security certications in
different levels and roles, and
works closely with universities
to implement the most current
security technologies.
-
7/29/2019 AI Solutions
9/169
Other
IED
Other
IED
SEL-35
1
SEL-35
1
SEL-35
1
SEL-36
10
IRIG-I
N
IRIG-IN
IRIG-IN
IRIG-IN
FirewallSEL ICON IntegratedCommunicationsOptical Network
SEL-7X
X
SEL-7X
X
SEL-36
20
ACCESS
IED ZONE
DATA
AGGREGATIONSEL-353
0SEL-3025
SEL-36
20
SEL-3530
SEL-3620
SEL-3354
SEL-3620 SEL-3025
SEL-3620
SEL-3620
SEL-3530 SEL-3610
Other IEDOther IED
Other IED
SEL-351
SEL-3620
SEL-3530 SEL-3610
Other IEDOther IED
Other IED
Other IEDOther IED
Other IED
SEL-3610
SEL-351SEL-351
Substation
Cisco Device
SEL-3620 EthernetSecurity Gateway
SEL-3620 EthernetSecurity Gateway
Other IEDs
Serial Relays
SEL-3025 SerialShield
SEL ICON IntegratedCommunicationsOptical Network
SEL-3610 SerialPort Server
SEL-3354 EmbeddedAutomationComputing Platform
Public
Eth
ernet
Link
PrivateTDMLink
RemoteAccess
WAN
LAN
IT Access
EngineeringAccess
Power SystemProtection
InformationTechnology
RegulatoryCompliance
SEL-3530Real-Time AutomationController (RTAC)
Scalability
SEL builds security from the system level. Whether you need tomanage one substation or hundreds, we create manageable,scalable solutions that make your system easier to control.
Zone 1: AccessSupplies strong access control for protecting both Ethernet andserial data entering or exiting the electronic security perimeter.Creates a proxy for legacy devices, instantly improving securitywithout firmware upgrades.
Zone 3: IED or ProcessProvides user and administrative access with strong passwords,port enable/disable, and alarm contacts, informing appropriatesystems of events or changes to settings.
Zone 2: Data AggregationProvides strong access control through port-level security,configurable access levels on local and remote access, strongauthentication, and secure protocols.
High Availability at the Substation
Mirror user rights and permissions using an SEL-3354Embedded Computer and Windows Server 2008. Thisallows personnel to continue accessing the substationas they normally would if the communications link tothe main Active Directory server is not accessible.
Centralized Logging
Integrate into existing log management systems using Syslog.Off-site log storage also means easier compliance with NERCCIP critical infrastructure event logging rules and regulations.
3:14PM: Admin: Login Attempt...
3:15PM: Admin: Login Attempt...3:16PM: Admin: Login Attempt...3:17PM: Admin: Login Attempt...
3:52PM: Admin: Login Attempt...
Central Authentication
Query central directories, including Microsoft ActiveDirectory, using Lightweight Directory Access Protocol(LDAP). System administrators can easily add and removerole-based accounts to specific devices from a centrallocation.
Im Bob. I need accessto the SEL-3620.
Yes, Bob isapproved.
Bob isnt in the localdatabase. Is Bob
an approved user?
Password Management
Manage IED passwords quickly and efficiently. UsingACSELERATOR TEAM SEL-5045 Software, you may evenmanage multivendor IEDs with the TEAM scriptinginterface.
Compliance
Examine what enters the electronic security perimeter(ESP) by visualizing routes, open ports, and services.Powerful, flexible access controls are centrally managed,and user-based access controls ensure that access to thesubstation is only provided at the level needed to
accomplish the job.
SEL offers complete end-to-end cybersecuritysolutions for critical infrastructure applications.
-
7/29/2019 AI Solutions
10/1610
Improve your systems reliability, reduce program
development time, and simplify connectivity with
RTU replacement solutions from SEL. SEL solutions
use substation-hardened devices and are economical,
dependable, and easy to use. The graphic to the right
shows a typical RTU replacement scheme by SEL formonitoring and controlling switchgear equipment.
Your application may require different I/O congu-
rations. Set up your own solutions, or let SEL help
you design custom solutions to meet your needs.
SEL University offers
WBT 2411S RTU Replacement
Using IEC 61850.
RTU Rep lacement
High-density modular I/O RTU solutions integrated directly with theSEL-3530 RTAC for rugged and flexible monitoring and control.
Combine a flexible network structure using copper or ber Ethernet cables tointegrate local and remote signals.
SEL-3354
SEL-2240
Ethernet
SCADA Master
SEL-2240
DNP3
Local HMI
Example RTU Replacement So lut ions
Simplify system design and gain greater performance byusing the SEL-2240 for high-density I/O applications.
The SEL-2240 directly integrates with the SEL-3530
RTAC, making conguration a snap. Easily create an
Ethernet network of SEL-2240 nodes. The EtherCAT
protocol provides deterministic performance and 1 ms
SER records.
Choose the RTAC and other devices as needed for RTU replacement. This product features an easy-to-use
IEC 61131-3 interface and a locally embedded, deterministic logic engine that allows you to manage your
collected data.
Easily combine and congure an SEL-3354 Embedded Automation Computing Platform and SEL-2411Programmable Automation Controller (PAC) to monitor and control your devices. Connect multiple IEDs
and support legacy protocols to send information directly to SCADA.
Improve communications by replacing pad-mounted switchgear RTUs with the IEC 61850-compatible
SEL-2411 PAC and wireless Ethernet peer-to-peer communications. This solution allows you to improve
your system by supporting remote automation with coordinated protection and autorestoration schemes.
Create RTUs of any size using IEC 61850 GOOSE networks.
-
7/29/2019 AI Solutions
11/1611
From analysis to implementation, SELs compre-
hensive distribution automation products enhance
voltage and power quality optimization programs
and improve reliability statistics for SAIDI, CAIDI,
SAIFI, and MAIFI. Once implemented, the system will
analyze, isolate, and restore power. SEL distributionautomation systems using information processors and
integrated IEDs enable you to supervise the restora-
tion of alternative sources based on parameters you
set with the information processor, such as abnormal
circuit conguration, hot-line tags, nonreclose status,
disabled supervisory control, or communications
failure. SEL distribution automation schemes include
the following:
Normal/standby source transfer
Main-tie-main scheme
Automatic load restoration
Automatic fault line sectionalizing
Automatic reconguration for restoration
Automatic source transfer
SCADA
Circuit A
CB HCB J
R5 R1
Circuit B
R4
R3
R2
Distribution AutomationControl System
Comms
Comms
Non-SEL Control
Relay Relay
Non-SEL Control
SEL-651R
SEL-351R
SEL-651R
Comms Comms
Comms
Comms
SEL-3354
SEL-351R
SEL-651R
SEL RelaySEL Relay
SEL-651R
SEL-651R
Distribution automation control system architecture.
Since 1999, SEL has been implementing distributionautomation solutions to automatically sectionalizea faulted line and recongure the grid to restoreservice to unfaulted sections, such as the one atInternational Drive, Orlando, Florida.
Analyze
IsolateRestore
Analyze and detect fault conditions
Isolate the affected feeder section
Restore power to unaffected sections
SEL Products Enable
Distribution Automation
Distr ibut ion Automat ion
-
7/29/2019 AI Solutions
12/1612
SEL remedial action schemes (RAS) protect against
blackouts and system instability, increase corridor
capacity limits, increase reliability, respond automati-
cally to system contingencies, and bring your system
operation closer to its stability limits.
With remedial action schemes from SEL, you candetect and automatically respond to multiple,
consecutive system contingencies. Control thou-
sands of contingencies and loads with high-speed
MirroredBitscommunications or IEC 61850 GOOSE
messages. Preserve system stability using intelligent,
contingency-based actions, such as flexible load and
generation shedding. All loads and generation can be
prioritized and shed only when necessary to satisfy the
contingency. Remedial action schemes detect unstable
power conditions and automatically take corrective
action, such as system islanding, to avoid blackouts.Let SEL Engineering Services design a remedial action
scheme for your system.
ProgrammableAutomationController
I/O Module
I/O Module
SEL Relay
Tough Computer
Leased Line/Serial
VPN/Ethernet
VPN/Ethernet
Substation #1
Substation #2
Substation #3
SEL Relay
SEL Meter
SEL-734
SEL-421
SEL-2505
SEL-2505
SEL-351S
SEL-2411
SEL Remedial
Action Scheme
SEL-3354
Remedial action scheme system architecture.
Remedia l Act ion Schemes
-
7/29/2019 AI Solutions
13/1613
SEL information processors support standard as well
as customized SCADA applications with real-time
access and control.
Use SEL information processors, such as the
SEL-3354 Embedded Automation Computing
Platform or the SEL-3530 RTAC, for SCADARTU and IED data collection and connectivity.
Create distribution management systems (DMS) to
avoid service interruptions, restore power quickly,
and manage load shedding, load flow, switch
order, automatic voltage control, disturbance
analysis, load management, and SER analysis.
Create energy management systems (EMS) for
automatic generation control, synchrophasor state
analysis, state estimation, operator load flow, load
management, contingency analysis, dispatcherload flow, and optimal power flow.
SEL-651R
SEL-2516Relay
SCADA Master
SEL-3010
Local HMI
SEL-2407
SEL-2410
DNP3 LAN/WAN
Recloser Control
Protection, Control,Reporting, I/O
Digital I/ORadio
Modem
PhoneEvent Messenger
GPS Clock
EngineeringAccess
Digital Outputs,Analog Inputs, Time-Tagged Digital Inputs
SEL-3530
SEL-3031
SEL-3354
SCADA connectivity converts protocols and communicatesnecessary information.
SCADA
-
7/29/2019 AI Solutions
14/1614
Load, top-oil and hot-spot temperatures, and coolingstage data are provided by the individual SEL-487ERelays protecting each transformer.
An individual transformer thermal report and graphuse relay data to show a 24-hour trend for thetransformer top-oil and hot-spot temperaturesaccumulated history.
SEL information processors form the data backbone
of a complete substation asset optimization system
by collecting, sorting, and storing information before
sending it to a system-wide database. SEL asset opti-
mization solutions provide the secure, concise, and
controlled data that asset and maintenance managersneed.
Optimize the life cycle of your assets by monitoring
key health indicators, and improve maintenance
scheduling, life cycle management, reliability
programs, and power quality management. Contin-
uous monitoring of transformer and circuit breaker
operating conditions can help you evaluate wear,
allowing you to schedule or avoid unnecessary main-
tenance, improve physical management of assets, and
improve system loading. Cost-effective, data-driven
maintenance schedules, allowed by SEL Asset Optimi-zation, reduce maintenance costs, increase asset life,
help engineers make informed decisions, and maxi-
mize engineering resources.
Asset optimization monitoring and notication architecture.
Asset Opt imizat ion
SEL-3354 SEL-3010
SEL-2800 SEL-2890
Transformer
CircuitBreaker
StationBatteries
RTD Module
Fiber-OpticTransceiver
EthernetTransceiver
TransformerProtection Relay
EventMessenger
Tough Computeras Information Processor
SEL-2600
SEL-
487E
-
7/29/2019 AI Solutions
15/1615
We are ready to assist with all of your automation and
integration needs. Let us help you nd the right solu-
tion for your unique situation.
SEL Engineer ing Serv ices
For more information on how to implement these
solutions and others, contact SEL, an SEL representa-
tive, or SEL Engineering Services. Learn more about
SEL Engineering Services at www.selinc.com/
engineeringservices.
SEL Univers i ty
We offer application and product-specic courses that
meet your training needs. In addition to scheduled
courses, SEL University offers on-site training, web-
based training (WBT), and computer-based training(CBT). For more information, visit the SEL University
website at www.selinc.com/selu.
SEL Support and Training
-
7/29/2019 AI Solutions
16/16
2350 NE Hopkins Court Pullman, WA 99163 USA
Tel: +1.509.332.1890 Fax: +1.509.332.7990
www.selinc.com [email protected]