ai solutions

Upload: memrah2955

Post on 14-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 AI Solutions

    1/161

    AUTOMATION AND INTEGRATION SOLUTIONS

    for Electric Power Systems

    Making Electric Power Safer, More Reliable, and More Economical

    IED Integration

    Event Monitoring, Collection, and Analysis

    Local HMI and Visualization

    Cybersecurity

    RTU Replacement

    Distribution Automation

    Remedial Action Schemes

    SCADA

    Asset Optimization

  • 7/29/2019 AI Solutions

    2/162

    Schweitzer Engineering Laboratories has delivered

    solutions for over 25 years that make electric power

    safer, more reliable, and more economical.

    SEL invented the worlds rst digital distance relay

    in 1984, revolutionizing fault location, event analysis,

    and protection. In 1999, south of Orlando, Florida,SEL implemented smart grid projects in the Interna-

    tional Drive power grid to automatically sectionalize a

    faulted line and recongure the grid to restore service

    to unfaulted sectionsall within six cycles.

    Leading in wide-area monitoring, protection, control,

    and analysis, SEL has installed over 31,000 SEL

    synchrophasor phasor-measurement-ready relays

    around the world.

    We offer engineering services, providing professional

    consulting and turnkey solutions for utility, industrial,and commercial markets worldwide.

    We also offer specialized training through SEL Univer-

    sity courses. Visit www.selinc.com/selu for more

    information and to register for courses.

    SEL designs and manufactures products for the

    worlds most challenging production environments

    to exceed all industry standards for temperature,

    shock, and electric stress. SEL products operate in a

    temperature range of40 to +85C (40 to +185F).

    They withstand electrostatic shock up to 15 kV and arevibration/shock resistant up to 15 g.

    We rigorously test our equipment in real-world condi-

    tions, producing products that lead the industry in

    their ability to withstand harsh substation environ-

    ments. Manufactured in Pullman, Washington, USA,

    SEL products exceed industry standards and come

    with a ten-year, no-questions-asked, worldwide

    warranty.

    Through a relentless focus on continual improvement,

    SEL achieves ever-increasing levels of quality, delivery,

    and service performance. Since 2004, in indepen-

    dent studies conducted by Newton-Evans Research

    Company, Inc., electric utilities have ranked SEL the

    North American leader in all categories surveyed,

    including technology, price, features, service, and

    security.

    About SEL Rel iab i l i ty

    Power Plant

    Factory

    Distribution SubstationControl Enclosure

    Motor-Operated Air BreakSwitch Control

    UndergroundFaulted Circuit

    Indicators

    Overhead

    Faulted CircuitIndicators

    Automated Pad-MountedSwitchgear

    Feeder Monitoring andCapacitor Bank Control

    Feeder Monitoring

    Renewable Energies

    RecloserControl

    Advanced MeteringSolutions

    Advanced MeteringSolutions

    Voltage RegulationControl

    Single-Phase RecloserMonitoring

    Transmission Substation

    Control Enclosure

    From the generating station to the end of a distrib ution line, SEL solutions make the electric p ower grid smarter by providing protection, communications, sensing,monitoring, security, and control.

  • 7/29/2019 AI Solutions

    3/163

    Today, SEL offers robust automation and integration

    solutions for your applications and is committed to

    leading with the best, most economical solutions.

    We offer technologies, products, systems, and services

    that address the entire application spectrum, from

    communicating with a single relay to integratingand automating the metering, control, reporting, and

    protection for a large system. In electrical substations,

    commercial sites, and generating, manufacturing, and

    processing plants, apply SEL microprocessor-based

    relays to protect the electrical system. Apply SEL

    networking, control, and communications solutions to

    integrate devices for data acquisition plus remote and

    local control.

    SEL relays, information processors, and systems

    support many architectures. SEL information proces-

    sors include real-time automation controllers (RTACs),

    communications processors, and tough computers

    with appropriate software.

    Choose tough SEL computing and networking prod-

    ucts that are far more reliable and robust than ofce or

    industrial computer equipment and ideal for protocol

    conversion, local human-machine interfaces (HMIs),

    event report collection, data concentration, and more.

    Many SEL relays include local, remote, and latched

    control switches and display points. With these

    features, you can replace or eliminate many external

    devices and associated panels, documentation, wiring,commissioning, testing, and maintenance. You benet

    from reduced total cost, improved system reliability,

    and state-of-the-art protection, monitoring, and

    control.

    Information processors support external communica-

    tions links, including the public switched telephone

    network for engineering access or dial-out alerts,

    private line connections to your SCADA system,

    and wide-area networks (WANs). Many SEL relays

    and controllers have integral protocols and ports for

    connection to networks. The SEL ICON provides the

    ber-optic communications backbone.

    SEL products and services are components of complete

    SEL solutions for instrumentation, protection,

    reporting, monitoring, local and remote control, and

    automation.

    Automat ion and Integrat ion Overview

    Block diagram of typical utility communications infrastructure.

    Satellite-Synchronized Clock

    Satellite-Synchronized Clock

    SEL-2407

    Relays, Controllers,and Other IEDs

    Event Messenger

    Dial-UpVoice Link

    Dial-UpData Link

    SerialSCADA Link

    Serial SCADA Link

    EncryptData

    Encrypt Data

    Modem

    Relays andOther IEDs

    EncryptData

    Station LAN

    Other IED

    SEL-2407

    Relay

    Relay

    Interleaved ASCIIand Binary Data forMost SEL Products,

    Noninterleaved for Others

    SEL-3010

    ProgrammableAutomation Controller

    Remote I/OModule

    Remote I/OModule

    Other IED

    Relay

    SEL-2515

    SEL-2516

    SEL-2411

    Human-Machine

    Interface

    Relays, Controllers,and Other IEDs

    Information Processor

    Information ProcessorInformation Processor

    Tough Computer

    IntegratedCommunicationsOptical Network

    IntegratedCommunicationsOptical Network

    Security Gateway

    Security Gateway

    Remote I/OModule

    EthernetSwitch

    EthernetSwitch

    Other IEDSEL-2516

    PDC

    Annunciator

    Port Server

    RTU

    Relays, Controllers,and Other IEDs

    Discrete ProgrammableAutomation Controller

    Copper Ethernet

    Copper Ethernet

    Fiber-OpticEthernet

    Copper Ethernet Relay

    SEL-2725

    SEL-2725

    SEL-2440

    SEL-3354

    SEL-3373

    SEL-3620

    SEL-3620

    SEL-3610

    SEL-2533

    SEL-551

    SEL-751A

    SEL-3530

    SEL-3530

    SEL-3530

    SEL-2240

  • 7/29/2019 AI Solutions

    4/164

    SEL information processors enable you to design and

    implement both simple and complex intelligent elec-

    tronic device (IED) integration solutions. Supported

    peer-to-peer technologies include SELs patented

    Mirrored Bits communications and IEC 61850.

    SEL Informat ion Processors

    With protocols, I/O, and easy-to-use interfaces, SEL

    information processors like the RTAC offer data

    acquisition, control, and automatic notication for

    both SEL and non-SEL IEDs.

    SELs newest information processor, the SEL-3530

    Real-Time Automation Controller (RTAC), is the next

    generation in automation control. The RTAC features

    secure communications, advanced data concentra-

    tion, high-speed logic processing, flexible engineeringaccess, and protocol conversion capabilities between

    multiple built-in client/server protocols. The RTAC

    also provides the tools necessary to easily integrate

    and concentrate information from the wide variety

    of microprocessor-based devices found in todays

    substations.

    SEL University offers WBT 3332

    Conguring Logical Expressions Using

    the SEL-3332 Intelligent Server and

    SEL-3351 System Computing Platform.

    IED Integration

    SEL-3530

    SEL-2725

    Five-Port EthernetSwitch

    SEL-3354

    LocalHMI SEL MirroredBitsRelaysEngineering

    Encrypted Link

    SEL Switch

    GOOSE Messaging

    DNP3, Modbus,IEC 61850

    EIA-232 Mirrored BitsCommunications Links

    Protocol conversion and data concentration with local control.

  • 7/29/2019 AI Solutions

    5/165

    IEC 61850 and GOOSE Messaging

    SEL products support IEC 61850 and GOOSE,

    allowing you to combine IEC 61850 technology,

    Ethernet networking, and SEL high reliability

    to perform station computing, automation,

    and control. Find out more about IEC 61850and GOOSE messaging solutions, case studies, and technical

    papers on the SEL website at www.selinc.com/61850 .

    Display and control using operational data in IEC 61850 logical nodesvia LAN for local HMI, and WAN for remote SCADA. Engineers use WANto congure devices and to retrieve and analyze event reports andsequential events records.

    Relay 1 sends high-speedGOOSE messages to Relay 2.

    SEL-387

    Relay 1

    Relay 2 sends high-speedGOOSE messages to Relay 1.

    Relay 2

    SEL-451

    Ethernet Switch

    SEL-2725

    Five-PortEthernetSwitch

    Use IEC 61850 GOOSE messages to communicate high-speed information betweenlocal relays or other devices on the local-area network (LAN). Examples includebreaker position, breaker trip, interlocking, and load-shedding commands.

    3

    1

    3

    1

    52

    52

    Source #1

    Source #2

    Recloser

    Recloser

    Hospital

    (critical load)

    (up to 20 miles

    using SEL-3031)

    MIRRORED BITS

    Communications

    SEL-351R

    SEL-351R

    MirroredBitscommunications recloser application

    SEL Serial Radio

    Transceiver

    SEL Serial Radio

    Transceiver

    Fiber-Optic

    Audio

    Radio

    Wave

    Available

    CommunicationsPaths

    SEL-311C SEL-311C

    SEL-3031SEL-3031

    MirroredBitscommunications transmitted over radio channels.

    EngineeringOffice Desktop

    PC

    ControlCenter SCADAMaster

    Wide-Area Network

    SEL-

    451-4

    SEL-311L

    SEL-387

    SEL-

    421

    SEL-

    487B

    SEL-

    451

    Local HMI

    SEL-2411

    SEL-710 SEL-751A

    SEL-3354

    SEL M i r rored B i ts Communicat ions

    Mirrored Bits communications is an innovative, low-cost, relay-to-

    relay communications technology that exchanges the status of eight

    internal logic points called Mirrored Bits, encoded in a digital message,

    between two devices. This patented technology opens the door to

    numerous integration applications that would otherwise require more

    expensive external communications equipment wired through contacts

    and control inputs. Integration applications for Mirrored Bits commu-

    nications include line protection pilot schemes, remote device controland monitoring, relay cross-tripping, and more.

    Apply Mirrored Bits communications over radio channels for direc-

    tional comparison protection schemes. This provides fast fault clearing

    and preserves transient and voltage stability at very low cost. For

    additional information on integrating your applications using

    Mirrored Bits, visit www.selinc.com/mirroredbits .

  • 7/29/2019 AI Solutions

    6/166

    In 1984, SEL invented the worlds rst digital distance

    relay with a built-in fault locator, revolutionizing fault

    nding. Current SEL event reporting technology and

    software, such as the ACSELerAtor Analytic Assistant

    SEL-5601 Software, makes wide-area monitoring,

    collection, analysis, and control of power system datapossible.

    Integrated systems with SEL synchrophasors take

    event analysis one step further by providing the ability

    to monitor power system distur-

    bances in real time through angle

    measurements, modal analysis, and

    out-of-step detection. You can view

    time-synchronized events together

    using the SEL-5601 Software. SEL

    uses the SEL-3378 Synchrophasor

    Vector Processor (SVP) to createreal-time, wide-area monitoring,

    protection, automation, and control

    solutions.

    The magnitude of the Northeast

    power blackout on August 14, 2003,

    could have been prevented, and

    the data analyzed in minutes rather

    than months, by using an SEL

    integrated and synchronized event

    monitoring and analysis solution.

    Another outage in Florida on February 26, 2008, was

    quickly analyzed by engineers using an SEL integrated

    and synchronized solution. The engineers then used

    their synchronized solution to improve their models

    and prevent similar situations in the future. A NERC

    press release on the Florida outage stated that synchro-phasors are like the MRI of the bulk power system.

    SEL University offers

    the following classes

    in event monitoring,

    collection, and analysis:

    WBT 101 Event Report

    Analysis Workshop

    WBT 102 Event Report

    Analysis Workshop for

    Distribution Relays

    CBT 102 Retrieving Event

    Reports for Technicians

    CBT 103 Analyzing Event

    Reports for Engineers

    Line Trip

    System Separation

    Line Trip and Generation Drop

    Seconds

    MW

    Amplitude = 42.02Damping Ratio = 3.22%Frequency = 0.232 Hz

    Amplitude = 1 6.74Damping Ratio = 0.76%Frequency = 0.258 Hz

    Amplitude = 32.71Damping Ratio = 8.9%Frequency = 0.263 Hz

    SEL-3378SEL-421

    300 400 500100 2000

    1150

    1350

    1550

    1750

    1400

    1500

    1600

    1525

    1545

    1565

    1500t

    MW

    MW

    MW

    t t

    1550

    1600

    Negative Damping RatioDamping Ratio < 10% Damping Ratio < 3%

    Line tripping, loss of generation, and other system events cause power oscillations. Use theSVP to identify oscillations in the early stages and alert power system operators to potentiallyunstable operating conditions.

    Event Monitoring , Co l lect ion, and Ana lys is

  • 7/29/2019 AI Solutions

    7/167

    SEL IEDs and tough computers monitor the status

    of communications lines and logic controllers,

    summarizing power system data (MW, MVAR,

    voltage, and current) and interfacing with settings for

    power management and remedial action schemes.

    Display one-line diagrams, alarms,communications diagrams, and many other useful

    tools with the substation touchscreen.

    SEL remote I/O modules and alarm panels

    provide quick indication status and alarm

    annunciation.

    Connect to information processors and IEDs to

    gather data, perform operations, and display the

    information you want.

    Loca l HMI and V isua l izat ion

    SEL tough computers support a wide variety of visualizations for local HMI.

  • 7/29/2019 AI Solutions

    8/168

    Implement cybersecurity with substation-hardened

    products from SEL. SEL relays and information

    processors contain strong electronic access-control

    technologies to effectively secure your cyberassets.

    The SEL-3620 Ethernet Security Gateway secures

    all Ethernet communications between your privatenetworks and interoperates with existing business IT

    and control systems over an Internet Protocol Security

    (IPsec) virtual private network (VPN). The SEL-3620

    protects your private network from malicious trafc

    with an integrated rewall and strong authentication

    access control.

    The SEL-3025 Serial Shield, an EIA-232, bump-in-

    the-wire serial cryptographic transceiver, protects

    meters, protective relays, programmable logic

    controllers (PLCs), remote terminal units (RTUs),

    and computers. The SEL-3025 prevents unauthorized

    access, control, monitoring, and malicious attacks

    by authenticating and optionally encrypting all data

    along the communications path.

    Our tough computers are also used in security solu-

    tions for their inherent authentication, security

    management, IPsec IP ltering, encryption, logging,

    password protection, and authentication features.

    Combine SEL technology with your policies, proce-

    dures, and training for a complete solution. For more

    information, visit www.selinc.com/cybersecurity .

    SEL University offers:

    APP 3620 Sensible Cybersecurity

    Using the Ethernet Security Gateway

    COM 203 SEL Cybersecurity Best

    Practices for Critical Infrastructure

    Where Is the Network Vulnerable to Intrusion?

    SCADA Control Center

    Real-Time Protection

    Substation orGeneration Facility

    Remote Monitoring or Billing

    Satellite

    Private or PublicTCP/IP Network

    Remote Access

    SCADA/RemoteAccess

    EngineeringAccess

    Telecom

    NetworkWAN

    Public TelephoneNetwork

    Wireless

    Dedicated Fiber,Wire, or Cable

    Internet

    SCADA/MeteringCommunications

    Cybersecur ity

    SEL employs a number of

    individuals with professional

    security certications in

    different levels and roles, and

    works closely with universities

    to implement the most current

    security technologies.

  • 7/29/2019 AI Solutions

    9/169

    Other

    IED

    Other

    IED

    SEL-35

    1

    SEL-35

    1

    SEL-35

    1

    SEL-36

    10

    IRIG-I

    N

    IRIG-IN

    IRIG-IN

    IRIG-IN

    FirewallSEL ICON IntegratedCommunicationsOptical Network

    SEL-7X

    X

    SEL-7X

    X

    SEL-36

    20

    ACCESS

    IED ZONE

    DATA

    AGGREGATIONSEL-353

    0SEL-3025

    SEL-36

    20

    SEL-3530

    SEL-3620

    SEL-3354

    SEL-3620 SEL-3025

    SEL-3620

    SEL-3620

    SEL-3530 SEL-3610

    Other IEDOther IED

    Other IED

    SEL-351

    SEL-3620

    SEL-3530 SEL-3610

    Other IEDOther IED

    Other IED

    Other IEDOther IED

    Other IED

    SEL-3610

    SEL-351SEL-351

    Substation

    Cisco Device

    SEL-3620 EthernetSecurity Gateway

    SEL-3620 EthernetSecurity Gateway

    Other IEDs

    Serial Relays

    SEL-3025 SerialShield

    SEL ICON IntegratedCommunicationsOptical Network

    SEL-3610 SerialPort Server

    SEL-3354 EmbeddedAutomationComputing Platform

    Public

    Eth

    ernet

    Link

    PrivateTDMLink

    RemoteAccess

    WAN

    LAN

    IT Access

    EngineeringAccess

    Power SystemProtection

    InformationTechnology

    RegulatoryCompliance

    SEL-3530Real-Time AutomationController (RTAC)

    Scalability

    SEL builds security from the system level. Whether you need tomanage one substation or hundreds, we create manageable,scalable solutions that make your system easier to control.

    Zone 1: AccessSupplies strong access control for protecting both Ethernet andserial data entering or exiting the electronic security perimeter.Creates a proxy for legacy devices, instantly improving securitywithout firmware upgrades.

    Zone 3: IED or ProcessProvides user and administrative access with strong passwords,port enable/disable, and alarm contacts, informing appropriatesystems of events or changes to settings.

    Zone 2: Data AggregationProvides strong access control through port-level security,configurable access levels on local and remote access, strongauthentication, and secure protocols.

    High Availability at the Substation

    Mirror user rights and permissions using an SEL-3354Embedded Computer and Windows Server 2008. Thisallows personnel to continue accessing the substationas they normally would if the communications link tothe main Active Directory server is not accessible.

    Centralized Logging

    Integrate into existing log management systems using Syslog.Off-site log storage also means easier compliance with NERCCIP critical infrastructure event logging rules and regulations.

    3:14PM: Admin: Login Attempt...

    3:15PM: Admin: Login Attempt...3:16PM: Admin: Login Attempt...3:17PM: Admin: Login Attempt...

    3:52PM: Admin: Login Attempt...

    Central Authentication

    Query central directories, including Microsoft ActiveDirectory, using Lightweight Directory Access Protocol(LDAP). System administrators can easily add and removerole-based accounts to specific devices from a centrallocation.

    Im Bob. I need accessto the SEL-3620.

    Yes, Bob isapproved.

    Bob isnt in the localdatabase. Is Bob

    an approved user?

    Password Management

    Manage IED passwords quickly and efficiently. UsingACSELERATOR TEAM SEL-5045 Software, you may evenmanage multivendor IEDs with the TEAM scriptinginterface.

    Compliance

    Examine what enters the electronic security perimeter(ESP) by visualizing routes, open ports, and services.Powerful, flexible access controls are centrally managed,and user-based access controls ensure that access to thesubstation is only provided at the level needed to

    accomplish the job.

    SEL offers complete end-to-end cybersecuritysolutions for critical infrastructure applications.

  • 7/29/2019 AI Solutions

    10/1610

    Improve your systems reliability, reduce program

    development time, and simplify connectivity with

    RTU replacement solutions from SEL. SEL solutions

    use substation-hardened devices and are economical,

    dependable, and easy to use. The graphic to the right

    shows a typical RTU replacement scheme by SEL formonitoring and controlling switchgear equipment.

    Your application may require different I/O congu-

    rations. Set up your own solutions, or let SEL help

    you design custom solutions to meet your needs.

    SEL University offers

    WBT 2411S RTU Replacement

    Using IEC 61850.

    RTU Rep lacement

    High-density modular I/O RTU solutions integrated directly with theSEL-3530 RTAC for rugged and flexible monitoring and control.

    Combine a flexible network structure using copper or ber Ethernet cables tointegrate local and remote signals.

    SEL-3354

    SEL-2240

    Ethernet

    SCADA Master

    SEL-2240

    DNP3

    Local HMI

    Example RTU Replacement So lut ions

    Simplify system design and gain greater performance byusing the SEL-2240 for high-density I/O applications.

    The SEL-2240 directly integrates with the SEL-3530

    RTAC, making conguration a snap. Easily create an

    Ethernet network of SEL-2240 nodes. The EtherCAT

    protocol provides deterministic performance and 1 ms

    SER records.

    Choose the RTAC and other devices as needed for RTU replacement. This product features an easy-to-use

    IEC 61131-3 interface and a locally embedded, deterministic logic engine that allows you to manage your

    collected data.

    Easily combine and congure an SEL-3354 Embedded Automation Computing Platform and SEL-2411Programmable Automation Controller (PAC) to monitor and control your devices. Connect multiple IEDs

    and support legacy protocols to send information directly to SCADA.

    Improve communications by replacing pad-mounted switchgear RTUs with the IEC 61850-compatible

    SEL-2411 PAC and wireless Ethernet peer-to-peer communications. This solution allows you to improve

    your system by supporting remote automation with coordinated protection and autorestoration schemes.

    Create RTUs of any size using IEC 61850 GOOSE networks.

  • 7/29/2019 AI Solutions

    11/1611

    From analysis to implementation, SELs compre-

    hensive distribution automation products enhance

    voltage and power quality optimization programs

    and improve reliability statistics for SAIDI, CAIDI,

    SAIFI, and MAIFI. Once implemented, the system will

    analyze, isolate, and restore power. SEL distributionautomation systems using information processors and

    integrated IEDs enable you to supervise the restora-

    tion of alternative sources based on parameters you

    set with the information processor, such as abnormal

    circuit conguration, hot-line tags, nonreclose status,

    disabled supervisory control, or communications

    failure. SEL distribution automation schemes include

    the following:

    Normal/standby source transfer

    Main-tie-main scheme

    Automatic load restoration

    Automatic fault line sectionalizing

    Automatic reconguration for restoration

    Automatic source transfer

    SCADA

    Circuit A

    CB HCB J

    R5 R1

    Circuit B

    R4

    R3

    R2

    Distribution AutomationControl System

    Comms

    Comms

    Non-SEL Control

    Relay Relay

    Non-SEL Control

    SEL-651R

    SEL-351R

    SEL-651R

    Comms Comms

    Comms

    Comms

    SEL-3354

    SEL-351R

    SEL-651R

    SEL RelaySEL Relay

    SEL-651R

    SEL-651R

    Distribution automation control system architecture.

    Since 1999, SEL has been implementing distributionautomation solutions to automatically sectionalizea faulted line and recongure the grid to restoreservice to unfaulted sections, such as the one atInternational Drive, Orlando, Florida.

    Analyze

    IsolateRestore

    Analyze and detect fault conditions

    Isolate the affected feeder section

    Restore power to unaffected sections

    SEL Products Enable

    Distribution Automation

    Distr ibut ion Automat ion

  • 7/29/2019 AI Solutions

    12/1612

    SEL remedial action schemes (RAS) protect against

    blackouts and system instability, increase corridor

    capacity limits, increase reliability, respond automati-

    cally to system contingencies, and bring your system

    operation closer to its stability limits.

    With remedial action schemes from SEL, you candetect and automatically respond to multiple,

    consecutive system contingencies. Control thou-

    sands of contingencies and loads with high-speed

    MirroredBitscommunications or IEC 61850 GOOSE

    messages. Preserve system stability using intelligent,

    contingency-based actions, such as flexible load and

    generation shedding. All loads and generation can be

    prioritized and shed only when necessary to satisfy the

    contingency. Remedial action schemes detect unstable

    power conditions and automatically take corrective

    action, such as system islanding, to avoid blackouts.Let SEL Engineering Services design a remedial action

    scheme for your system.

    ProgrammableAutomationController

    I/O Module

    I/O Module

    SEL Relay

    Tough Computer

    Leased Line/Serial

    VPN/Ethernet

    VPN/Ethernet

    Substation #1

    Substation #2

    Substation #3

    SEL Relay

    SEL Meter

    SEL-734

    SEL-421

    SEL-2505

    SEL-2505

    SEL-351S

    SEL-2411

    SEL Remedial

    Action Scheme

    SEL-3354

    Remedial action scheme system architecture.

    Remedia l Act ion Schemes

  • 7/29/2019 AI Solutions

    13/1613

    SEL information processors support standard as well

    as customized SCADA applications with real-time

    access and control.

    Use SEL information processors, such as the

    SEL-3354 Embedded Automation Computing

    Platform or the SEL-3530 RTAC, for SCADARTU and IED data collection and connectivity.

    Create distribution management systems (DMS) to

    avoid service interruptions, restore power quickly,

    and manage load shedding, load flow, switch

    order, automatic voltage control, disturbance

    analysis, load management, and SER analysis.

    Create energy management systems (EMS) for

    automatic generation control, synchrophasor state

    analysis, state estimation, operator load flow, load

    management, contingency analysis, dispatcherload flow, and optimal power flow.

    SEL-651R

    SEL-2516Relay

    SCADA Master

    SEL-3010

    Local HMI

    SEL-2407

    SEL-2410

    DNP3 LAN/WAN

    Recloser Control

    Protection, Control,Reporting, I/O

    Digital I/ORadio

    Modem

    PhoneEvent Messenger

    GPS Clock

    EngineeringAccess

    Digital Outputs,Analog Inputs, Time-Tagged Digital Inputs

    SEL-3530

    SEL-3031

    SEL-3354

    SCADA connectivity converts protocols and communicatesnecessary information.

    SCADA

  • 7/29/2019 AI Solutions

    14/1614

    Load, top-oil and hot-spot temperatures, and coolingstage data are provided by the individual SEL-487ERelays protecting each transformer.

    An individual transformer thermal report and graphuse relay data to show a 24-hour trend for thetransformer top-oil and hot-spot temperaturesaccumulated history.

    SEL information processors form the data backbone

    of a complete substation asset optimization system

    by collecting, sorting, and storing information before

    sending it to a system-wide database. SEL asset opti-

    mization solutions provide the secure, concise, and

    controlled data that asset and maintenance managersneed.

    Optimize the life cycle of your assets by monitoring

    key health indicators, and improve maintenance

    scheduling, life cycle management, reliability

    programs, and power quality management. Contin-

    uous monitoring of transformer and circuit breaker

    operating conditions can help you evaluate wear,

    allowing you to schedule or avoid unnecessary main-

    tenance, improve physical management of assets, and

    improve system loading. Cost-effective, data-driven

    maintenance schedules, allowed by SEL Asset Optimi-zation, reduce maintenance costs, increase asset life,

    help engineers make informed decisions, and maxi-

    mize engineering resources.

    Asset optimization monitoring and notication architecture.

    Asset Opt imizat ion

    SEL-3354 SEL-3010

    SEL-2800 SEL-2890

    Transformer

    CircuitBreaker

    StationBatteries

    RTD Module

    Fiber-OpticTransceiver

    EthernetTransceiver

    TransformerProtection Relay

    EventMessenger

    Tough Computeras Information Processor

    SEL-2600

    SEL-

    487E

  • 7/29/2019 AI Solutions

    15/1615

    We are ready to assist with all of your automation and

    integration needs. Let us help you nd the right solu-

    tion for your unique situation.

    SEL Engineer ing Serv ices

    For more information on how to implement these

    solutions and others, contact SEL, an SEL representa-

    tive, or SEL Engineering Services. Learn more about

    SEL Engineering Services at www.selinc.com/

    engineeringservices.

    SEL Univers i ty

    We offer application and product-specic courses that

    meet your training needs. In addition to scheduled

    courses, SEL University offers on-site training, web-

    based training (WBT), and computer-based training(CBT). For more information, visit the SEL University

    website at www.selinc.com/selu.

    SEL Support and Training

  • 7/29/2019 AI Solutions

    16/16

    2350 NE Hopkins Court Pullman, WA 99163 USA

    Tel: +1.509.332.1890 Fax: +1.509.332.7990

    www.selinc.com [email protected]