AIR GUARG - Air quality control system Petrik Naval S.L. Petko Belomirov Stoynov CEO 13 de agosto de 2017 AIR GUARD Air Quality Control System Because the air quality on board matters Petrik Naval S.L. * Marine Automation System Development * [email protected] Crtra Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379 Phone +34 661 707 124 ISO 9001, ISO 14001, OHSAS 18001

Upload: doandang

Post on 12-Aug-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

AIR GUARG - Air quality control system

Petrik Naval S.L. Petko Belomirov Stoynov CEO 13 de agosto de 2017

AIR GUARD

Air Quality Control System

Because the air quality on board matters

Petrik Naval S.L. * Marine Automation System Development * [email protected] Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379

Phone +34 661 707 124ISO 9001, ISO 14001, OHSAS 18001

AIR GUARG - Air quality control system

APLICATION

The system is applicable to every cargo ship and passenger ship fitted with power ventilation system with vehicle, special category space and ro-ro space.

REGULATION

Amendments to SOLAS Regulation II-2/20 were adopted to accept a decreased number of air changes and/or a decreased amount of ventilation in ro-ro or vehicle spaces where an air quality control system is provided.

The ventilation system fitted on such area may be operated at decreased number of air change and decreased amount of ventilation, if ship is fitted with air quality control system based on the guideline as per MSC.1/ Circ. 1515.

The Air Guard air quality system is measuring the CO,NO2 and LEL concentration values and regulates the air flow by changing the number of revolution of supply and exhaust ventilators.

Petrik Naval S.L. * Marine Automation System Development * [email protected] Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379

Phone +34 661 707 124ISO 9001, ISO 14001, OHSAS 18001

AIR GUARG - Air quality control system

The control system is designed for automatic and manual operation mode, override operation, alarm and monitoring of the air quality.

Any failure in the system including power failure of the control system, the ventilators switches to the capacity as required by ISO 9785:2002

The manufacturer’s instruction manual is available and delivered with the integration and includes the maintenance provisions, indicating frequency of testing and adjustment of the sensors.

The calibration, maintenance and testing of the system is to be carried out as per the instruction manual by authorised personal only.

All test results of the periodical test and verification are kept on a history log in the system. By this log can be verifies the adequacy of the air quality control system.

PERMISSIVE GAS LEVELS AND LIMITS

Alarm is given when the level exceeds 40 mg/m3 CO or 4 mg/m3 NO2 long-term exposure according to the standard ISO 9785:2002 or when a relative concentration of the atmosphere to the LEL is higher than 10%. Other more stringent exposure limits may be used when determined by the Administration, taking national or local occupational regulations into account.

MAIN FUNCTIONS AND FEATURES

CONTINUOUS GAS MONITORING AUTOMATIC AND MANUAL OVERRIDE OPERATION POWER LOSS ALARM SELF CHECK PROCEDURE SAFE MODE ESTABLISHMENT AS PER II-2/20.3.1.1 WHEELHOUSE OR CCR ALARM REAL TIME GAS CONCENTRATION INDICATION REAL TIME VENTILATOR PERCENTAGE INDICATION GAS CONCENTRATION TRENDS PER ZONE MIMIC ZONE INDICATION AUDIBLE ALARM MAIN AND BATTERY POWER SUPPLY

Petrik Naval S.L. * Marine Automation System Development * [email protected] Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379

Phone +34 661 707 124ISO 9001, ISO 14001, OHSAS 18001

AIR GUARG - Air quality control system

VENT CONTROL SYSTEM

Ventilators are controlled by the air quality control system in order to provide the appropriate number of air changes to restore the normal values of CO, NO2 and LEL as soon as those levels are exceeded during 5 minutes. The ventilation regime should be continuously regulated in relation to the increase of gas concentration and to restore normal levels of CO or NO2 as soon as possible. We provide tree control modes analog digital and discrete ModBus RS485 Variable Drive control.

TECHNICAL FEATURES

CO content range 0 - 200 mg/m3, Resolution 0,1 mg/m3

NO content range 0 - 100 mg/m3, Resolution 0,1 mg/m3

LEL content range 0 - 100%, Resolution 0,1%

Measuring response time Less Than 15 Seconds

Designed according to MSC.1/ Circ. 1515

Power supply 85 → 264 V ac, 100 → 350 V dc

UPS Battery supply Approximately 2 hours depends on sensors state.

Power consumption 400W

User interface HMI touch screen display 7” High resolution

Data log and retrieval via display History Log

Alarm 1 user adjustable range ( 0…10,0% LEL ); ( 0…40 mg/m3 CO ); ( 0…4 mg/m3 NO )

Alarm hysteresis 1 mg/m3

Humidity 15-90% RH non-condensing

Temperature range for measuring sensors -40ºC - 80ºC

Vent Control Type Control integration 4…20mA Output, ON/OFF, Modbus RTU, Modbus TCP/IP

Petrik Naval S.L. * Marine Automation System Development * [email protected] Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379

Phone +34 661 707 124ISO 9001, ISO 14001, OHSAS 18001

AIR GUARG - Air quality control system

SENSOR INSTALATION

The size of space to be monitored: In areas comprised of dividers, sections, corners and other barriers to free movement of air should be condensed to one sensor per 900 m2. Lesser number of sensors may be accepted based on calculations or measurements of the response time on air quality in the holds. Must be fitted at least one sensor per hold or space.

ADDITIONAL AIR QUALITY TESTS

Petrik Naval provides periodically additional air pollution tests to ensure the proper condition of the air quality on board. The concentrations of the following pollutants can be determined; nitric oxide (NO), nitrogen dioxide (NO2), carbon monoxide (CO). In addition

concentrations of benzene, toluene, xylene and suspended particulate matter (SPM) can also be determined whenever is required.

SYSTEM DESCRIPTION Petrik Naval S.L. * Marine Automation System Development * [email protected]

Crtra Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379Phone +34 661 707 124

ISO 9001, ISO 14001, OHSAS 18001

AIR GUARG - Air quality control system

TRAINING

Petrik Naval offers an extensive training course for the crew and all the dependences involved in the project.

Component Units Description

HMI 1 Pro Face Schneider Electric

GAS DETECTORS 9 Crowcon XgardShipbuilding Type Approvals LR-40 to +50oC (-40 to 122oF)15-90% RH non-condensingExd IIC T6 Gb(Tamb -40 to +50oC)Groups B, C, DIECExGOST-REN 50270FCC Part 15ICES- 003The sensors type and number can be adjusted depending on the requirements. According to the regulation must be placed one sensor of each gas every 900 m2.

CONTROLLER BOX 1 Components with reference and certificationMetcase Box M5840105UPS Phoenix Contact TRIO-UPS/1AC/24DC/ 5 - 2866611Battery Pack Phoenix Contact QUINT-BAT/24DC/ 3.4AH - 2866349PLC Controller Schneider Electric 1 x TM221M16RG, 3x TM3TI4GHMI Pro Face Schneider Electric

ALARM ANUNCIATOR 1 Hosiden Besson 90010R0

SERVICE AND USER MANUAL

1 Complete V2.1

Petrik Naval S.L. * Marine Automation System Development * [email protected] Térmica, Torres de Hercules T2a * Los Barrios, Cadiz, Spain CP 11379

Phone +34 661 707 124ISO 9001, ISO 14001, OHSAS 18001