Page 1: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)
Page 2: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

2

TOTALE CONSUMI ELETTRICI INDUSTRIALI

ca. 150 TWh/a

TOTALE CONSUMI ELETTRICI IMPUTABILI ALLA PRODUZIONE DI ARIA COMPRESSA

c.a. 13-16 TWh/a

In Italia da ultime stime pubblicate (rapporto UNIPV, in collaborazione con Enea, 2009)

Un risparmio medio del 5% permetterebbe la chiusura di tutte le centrali termoelettriche di produzione (esclusi autoproduttori) della Basilicata

Page 3: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

3

DEFINIZIONE DI RISPARMIO ENERGETICO: FORNIRE LO STESSO SERVIZIO ENERGETICO UTILIZZANDO MINORI RISORSE IN TERMINI DI ENERGIA PRIMARIA

... OSSIA AUMENTARE L'EFFICIENZA NELLA CATENA DI TRASFORMAZIONE DELL'ENERGIA

DRIVE

CPU

FAN

FEEDING SYSTEM

GEARS COMPRESSOR PIPINGS

DEVICES (STORAGE,

FILTERS,FITTINGS)

AIR TREATMENT (DRYER)

MASS LOSSES

PRESSURE DROPS

FINAL ENERGY

USE (AND (AND MISUSE)MISUSE)

AIR HEAT

5-12%100%

Page 4: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

4

pressione

portata l/s

Page 5: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

5

SECn@ pop=Pcq fad@ pop

SEC=Pc . hc+Pv . hvqc .hc

hc+hv+hoff=htot

sehoff=0hv=αhc

datauna particolaremacchina@ pop→Pv=βPc

SEC=Pc . hc+βPc .βhvqc .hc

SEC=SECn .(1+αβ)

Page 6: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014 6

CONFRONTO TRA MACCHINE regolate vuoto/carico e macchine a velocità variabile:Influenza dei parametri operativi

Page 7: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014 7

Page 8: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014 8

CONFRONTO TRA MACCHINE regolate vuoto/carico e macchine a velocità variabile

ALTRA QUESTIONE: IL DIMENSIONAMENTO DI UNA MACCHINA ED ILSUO PUNTO DI LAVORO

0 100 200 300 400 500 600 700 800 9000

50

100

150

200

250

300

P (and SEC) vs qadjustable speed 160 & 315 kW @ 0.7 MPa g

Pn 160 kW Pn 315 kW kWh/m3 -160 kWh/m3 – 315

l/s

kW

kWh/m3

Page 9: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

Page 10: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

10

*2* La pressione di esercizio di una rete gioca un ruolo fondamentale nella determinazione dei consumi, la varazione di 0,5 barr (50 kPa) nel settaggio delle pressioni di sala comporta cambio dei cicli di carico/vuoto dunque influisce sul calcolo dei consumi specifici

pmin

p'MAX

dpdt

=( ˙minp− ˙mout) . k˙minp> ˙mout

minp< ˙mout

tv1

tc

t

p'MAX

Page 11: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

11

20 % Power

100 % Power

*3* Cicli vuoto/carico:In presenza di macchine con alta incidenza (>30%) delle ore di vuoto su quelle di carico ed in presenza di macchine lubrificate l'espressione Etot=Ec+Ev+ f (n . cicli ; t)

Tiene meglio in considerazione i transitori tra potenza di carico e vuoto

Active Power consumption evolution from L to NL

0

10

20

30

40

50

0

20 40 60 80

100

120

140

160

180

200

220

240

260

seconds

kW

Page 12: AIR HEAT SYSTEM DRIVE GEARS · fan feeding system gears compressor ... devices (storage, filters,fittings) air treatment (dryer) mass losses pressure drops final energy use (and misuse)

Pavia, 18 Dicembre 2014

12

* UTILE POTREBBE ESSERE LA CREAZIONE DI BENCHMARK DI SETTORE (IMPORTANZA DELLE ASSOCIAZION IDI CATEGORIA O DEI SERVIZI DI SETTORE) CON DIFFERENZIAZIONE SU ALMENO 2/3 LIVELLI DI PRESSIONE BASSA (< 6bar) -MEDIA (<13 bar) -ALTA (oltre 20-30 bar) >>>>> CREAZIONE DI UNA PIATTAFORMA PER LO SCAMBIO DI INFORMAZIONI

* IMPORTANTI LE CONDIZIONI DI MISURA E IL PERIODO CAMPIONE EX ANTE, ANALISI DELLA MODALITà DI FUNZIONAMENTO CON STRUMENTI DIVERSIFICATI (ISTOGRAMMI, CURVE DI DURATA, ...)

* AGEVOLARE/INCREMENTARE L'UTILIZZO DI SCHEDE ANALITICHE