Page 2: Airfel Commercial Air Conditioners (ENG)

24.000 Btu/h46.500 Btu/h

18.500 Btu/h25.000 Btu/h46.000 Btu/h

• Enviromentally friendly R410A refrigerant• Simple design, wide digital display• Additional electrical heater• Long piping range• Long blowing range• Failure diagnose system• 4-way automatic air direction• Strong dehumidification• Indoor unit drying system• 24-hour timer• Sleep mode• Silent operation

FLOOR STANDING AIR CONDITIONERR410A

R410A

Effective air blowing range up to 15 meters with strong fan motors

Strong heating function designedfor stiff winter conditions

Indoor unit drying systempreventing odour and bacteria

3 dimensional homogenous air flow to up-down and right-left directions with automatic air direction wings

• Standard drainage pump• Long piping range• 4-way air blowing system• Strong filtering system• Failure diagnose system• Remote controller• Environmentally friendly R410A refrigerant

CASETTE TYPE AIR CONDITIONER

AFS24-0901F/R2 ACS18-0906C/R2 ACS24-0906C/R2 ACS44-0906C/R2AFS46-0901F/R2

Cooling

Heating

Cooling

Heating

Cooling

Heating

IU

IU

OU

IU

OU

IU

OU

Liquid

Gas

Heating

Cooling

Btu/h

kW

Btu/h

kW

V/Hz

A

A

kW

kW

lt/h

m3/h

dB (A)

dB (A)

mm

mm

kg

kg

m

m

inch - mm

inch - mm

m

gr

gr/m

°C

°C

24.090

7,06

26.600 (+7.160)

7,80 (+2,1)

220-240/50

14,3

14,3 (23,26)

2,43

2,35 (+2,1)

2,91

C

3,31

C

3

1.100

40/42/45

56

500x1757x300

1018x840x412

40

69

30

15

3/8" - 9,52

5/8" - 15,88

Havşa

5

Rotary

R410A

2.100

60

-7 / 24

21 / 43

46.500

13,63

50.000 (+8.500)

14,65 (+2,5)

380-415/50

8,9

8,7 (14)

4,63

4,56 (+2,5)

2,94

C

3,21

C

8,5

1.800

46/48/50

59

590x1870x395

1032x1250x412

63

112

30

20

1/2" - 12,7

3/4" - 19,05

Havşa

5

Scroll

R410A

3.600

100

-7 / 24

21 / 43

18.500

5,42

22.000

6,44

220-240/50

9

8,7

1,9

1,87

2,85

C

3,44

B

2

600

43/45/47

56

600x230x600

848x540x320

20

40

20

15

1/4" - 6,35

1/2" - 12,7

Havşa

5

Rotary

R410A

1.500

30

-7 / 24

21 / 43

25.000

7,32

27.000

7,91

220-240/50

11,9

11,4

2,42

2,3

3,02

B

3,44

B

2,7

1.180

43/45/47

59

840x260x840

1018x700x412

30

59

30

15

3/8" - 9,52

5/8" - 15,88

Havşa

5

Rotary

R410A

2.200

60

-7 / 24

21 / 43

44.000

12,89

49.500

14,5

380-415/50

8,7

8,5

4,28

4,5

3,01

B

3,22

C

7

1.650

48/51/53

60

840x320x840

950x1250x412

38

112

50

30

1/2" - 12,7

3/4" - 19,05

Havşa

5

Scroll

R410A

3.550

120

-7 / 24

21 / 43

FLOOR STANDING CASETTE TYPE

Model

Capacity

Cooling Capacity

Heating Capacity

Electrical Data

Power

Rated Current

Power Input

EER

COP

Performance

Dehumidifying

Air Flow(L/M/H)

Noise Level

Overview

Dimensions (WxHxL)

Net Weight

Max. Piping Lenght

Max. Level Difference

Flare Refrigerent Piping

Connection Type

Pre-charged Piping Length

Compressor Type

Refrigerant

Refrigerant Amount

Additional Refrigerant Charge

Operating Range

• The specifications are the values that are measured in standard test conditions.• Cooling test conditions: Outdoor unit ambient temperature 35°C (DB), 24°C (WB), indoor unit ambient temperature 27°C (DB), 19°C (WB) • Heating test conditions: Outdoor unit ambient temperature 7°C (DB), 6°C (WB), indoor un it ambient temperature 20°C (DB) • Airfel has the right to change product specifications and designs without giving information.* Panel values are after-installation values.

Page 3: Airfel Commercial Air Conditioners (ENG)

R410ADUCTED TYPE AIR CONDITIONER

• Failure diagnose system• Ceiling or floor installation alternatives• Fan structure designed for silent operation• Long piping range• Long blowing range• Remote controller

18.000 Btu/h• Efficient operation with duct connection• Silent operation• Remote controller• Environmentally friendly R410A refrigerant

R410AFLOOR - CEILING TYPE AIR CONDITIONER

24.000 Btu/h44.000 Btu/h60.000 Btu/h

24.750 Btu/h44.000 Btu/h

ADS18-0907D/R2 ADS44-0907D/R2 ADS60-0907D/R2 ACFS24-0908CF/R2 ACFS44-0908CF/R2ADS24-0907D/R2

Btu/h

kW

Btu/h

kW

V/Hz

A

A

kW

kW

lt/h

m3/h

dB (A)

dB (A)

mm

mm

kg

kg

m

m

inch - mm

inch - mm

m

gr

gr/m

°C

°C

18.000

5,28

20.000

5,86

220-240/50

9,4

8,04

1,88

1,7

2,81

C

3,45

B

2

840

38/40/42

56

1012x266x736

848x540x320

36

40

20

15

1/4" - 6,35

1/2" - 12,7

Havşa

5

Rotary

R410A

1.500

30

-7 / 24

21 / 43

24.000

7,03

27.500

8,06

220-240/50

12,1

11,4

2,33

2,36

3,02

B

3,42

B

2,7

1.400

40/42/44

59

1270x268x504

1018x700x412

37

59

30

15

3/8" - 9,52

5/8" - 15,88

Havşa

5

Rotary

R410A

2.200

60

-7 / 24

21 / 43

44.000

12,9

50.000

14,65

380-415/50

9,6

8,9

4,8

4,57

2,69

D

3,21

C

4

2.000

46/48/50

60

1251x290x744

950x1250x412

57

112

50

30

1/2" - 12,7

3/4" - 19,05

Havşa

5

Scroll

R410A

3.550

120

-7 / 24

21 / 43

60.000

17,59

63.000

18,5

380-415/50

11,8

10

6,2

5,4

2,84

C

3,43

B

7

2.500

48/50/53

64

1251x330x788

950x1250x412

66

123

50

30

1/2" - 12,7

3/4" - 19,05

Havşa

5

Scroll

R410A

5.000

120

-7 / 24

21 / 43

24.750

7,25

28.500

8,35

220-240/50

11,8

11,7

2,4

2,45

3,02

B

3,41

B

2,7

1.170

46/48/50

59

1300x188x600

1018x700x412

32

59

30

15

3/8" - 9,52

5/8" - 15,88

Havşa

5

Rotary

R410A

2.200

30

-7 / 24

21 / 43

44.000

12,89

50.000

14,65

380-415/50

8,7

8,5

4,5

4,55

2,86

C

3,22

C

4

1.800

48/51/54

60

1590x238x695

950x1250x412

42

112

50

30

1/2" - 12,7

3/4" - 19,05

Havşa

5

Scroll

R410A

3.550

120

-7 / 24

21 / 43

DUCTED TYPE FLOOR - CEILING TYPE

Cooling

Heating

Cooling

Heating

Cooling

Heating

IU

IU

OU

IU

OU

IU

OU

Liquid

Gas

Heating

Cooling

Model

Capacity

Cooling Capacity

Heating Capacity

Electrical Data

Power

Rated Current

Power Input

EER

COP

Performance

Dehumidifying

Air Flow(L/M/H)

Noise Level

Overview

Dimensions (WxHxL)

Net Weight

Max. Piping Lenght

Max. Level Difference

Flare Refrigerent Piping

Connection Type

Pre-charged Piping Length

Compressor Type

Refrigerant

Refrigerant Amount

Additional Refrigerant Charge

Operating Range

• The specifications are the values that are measured in standard test conditions.• Cooling test conditions: Outdoor unit ambient temperature 35°C (DB), 24°C (WB), indoor unit ambient temperature 27°C (DB), 19°C (WB) • Heating test conditions: Outdoor unit ambient temperature 7°C (DB), 6°C (WB), indoor un it ambient temperature 20°C (DB) • Airfel has the right to change product specifications and designs without giving information.* Panel values are after-installation values.

Page 4: Airfel Commercial Air Conditioners (ENG)

HIGH PERFORMANCE

SILENT TECHNOLOGYEnvironmentally Friendly...

Commercial Air Conditioners

Authorized Dealer

Rv:

R1:

01.

02.

2011

DAIKIN TURKEY Hürriyet Mah. E-5 Yan yol Üzeri no:57/2 Kartal / ISTANBUL/ TURKEYTel:(+90 216) 453 27 00 Pbx Fax: (+90 216) 671 06 19 [email protected]

www.daikin.com.tr • www.airfel.com