QMI Airscan® transducers are specifically designed for use in conjunction with QMI’s Sonda Airscan® Non-Destructive Inspection Instrumentation, and are not compatible with conventional ultrasonic instrumentation. For this reason, QMI does not supply these transducers apart from the Sonda line of instrumentation. QMI is not responsible for any damage resulting from the use of Airscan® transducers with instrumentation other than the Sonda line, nor will we warrant the transducer against damage from such use. .
AIRSCAN® TRANSDUCER APPLICATIONS TABLE
Airscan® Transducers
Suitable Applications Maximum Material
Thickness
AS50i (50kHz)
Wood & Engineered Wood Products Foam sandwich panel
Multi-septum parts Carbon Fiber Laminate
100mm*
AS120i (120kHz)
Foam sandwich panel Multi-septum parts
Honeycomb Sandwich Panels (FRC Face sheets, Aluminum Honeycomb Core)
Glass/Quartz Epoxy Laminate Carbon Fiber Laminate
75mm*
AS225i (200kHz)
Honeycomb Sandwich Panels (FRC Face sheets, Aluminum Honeycomb Core)
Glass/Quartz Epoxy Laminate Carbon Fiber Laminate
Silicon Carbide & Carbon/Carbon Panels
50mm*
AS400i (400kHz)
Honeycomb Sandwich Panels (FRC Face sheets, Aluminum Honeycomb Core)
Glass/Quartz Epoxy Laminate Carbon Fiber Laminate
Silicon Carbide & Carbon/Carbon Panels
25mm*
* Note: These thicknesses are readily penetrated by the frequencies as specified, but as material
thickness increases, so too does the minimum detectable defect size.
QU
AL
ITY
MA
TE
RIA
L IN
SP
EC
TIO
N IN
C, 5442 O
cean
us D
rive, H
un
tin
gto
n B
each
, C
A 9
2649, U
SA
. P
ho
ne:
714.9
03.4
500 w
ww
.qm
i-in
c.c
om
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS400ARi CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
3.750"
2.000"
DATE: 06/27/2003
ø0.7
50"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XXXX: +/- 0.001".XX: +/- 0.010"
.XXX: +/- 0.003"
MATERIAL: 2017 ALUMINUM
NOTE: SERIALIZE PER P.O.
FINISH: BLUE ANODIZED
ø1.4
75"
QMI, INC. AIRSCAN RECEIVER MODEL: AS400ARi SERIAL: XXXX
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
DRAWING NUMBER: NA0306003TITLE: CONFIG, AS400ARiSCALE: NONE
REV: 1
QMI, INC.
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS400ARiSerial Number: REFERENCETransducer Type: Airscan ReceiverFrequency: 400kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AM81NIST Report.: 1202022Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 12.5uJGain (dB): 20Attenuation (dB): 49H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 16.9
Pulse Frequency
usec 240 242 244 246 248 250 252 254 256
% 1
00
50
0
-50
-100
MHz 0.1 0.2 0.3 0.4 0.5 0.6 0.7
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 0.887 usec Peak Frequency: 0.440 MHzPulse Width @ -20dB: 8.537 usec Center Frequency: 0.417 MHzPeak to Peak Amplitude:174.170 % Low Frequency @ -3dB: 0.372 MHz
High Frequency @ -3dB: 0.461 MHzBandwidth @ -3dB: 21.399 %Low Frequency @ -6dB: 0.354 MHzHigh Frequency @ -6dB: 0.479 MHzBandwidth @ -6dB: 29.950 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS400ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS400ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -0.750 0.000Length: Length: 1.500 100.000Resolution: Resolution: 0.020 (75 points) 0.024 (4096 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS400ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.745 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.020 (75 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS400ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.020 (75 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS400ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.745 -0.750Length: Length: 1.500 1.500Resolution: Resolution: 0.020 (75 points) 0.020 (75 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
in 0
.6
0.4
0
.2
0.0
-0
.2
-0.4
-0
.6
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS400Ti CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
3.750"
2.000"
DATE: 06/27/2003
SCALE: NONE
ø0.7
5 0"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XX: +/- 0.010"
.XXX: +/- 0.003"
.XXXX: +/- 0.001"
MATERIAL: 2017 ALUMINUM
NOTE: SERIALIZE PER P.O.
FINISH: BLUE ANODIZED
ø1.4
75"
QMI, INC. AIRSCAN TRANSMITTER MODEL: AS400Ti SERIAL: XXXX
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
TITLE: CONFIG, AS400Ti
DRAWING NUMBER: NA0306006REV: 1
QMI, INC.
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS400TiSerial Number: REFERENCETransducer Type: Airscan TransmitterFrequency: 400kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AS92NIST Report.: 1211008Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 100uJGain (dB): 60Attenuation (dB): 12H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 93.9
Pulse Frequency
usec 248 250 252 254 256 258
% 1
00
50
0
-50
-100
MHz 0.1 0.2 0.3 0.4 0.5 0.6 0.7
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 0.741 usec Peak Frequency: 0.436 MHzPulse Width @ -20dB: 5.865 usec Center Frequency: 0.411 MHzPeak to Peak Amplitude:193.066 % Low Frequency @ -3dB: 0.362 MHz
High Frequency @ -3dB: 0.459 MHzBandwidth @ -3dB: 23.523 %Low Frequency @ -6dB: 0.344 MHzHigh Frequency @ -6dB: 0.478 MHzBandwidth @ -6dB: 32.758 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS400Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS400Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -0.500 0.000Length: Length: 1.000 100.000Resolution: Resolution: 0.010 (100 points) 0.024 (4096 points)
in -0.4 -0.3 -0.2 -0.1 -0.0 0.1 0.2 0.3 0.4 0.5
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS400Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.500 0.000Length: Length: 1.000 5.000Resolution: Resolution: 0.020 (50 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS400Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.500 0.000Length: Length: 1.000 5.000Resolution: Resolution: 0.020 (50 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS400Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.500 -0.500Length: Length: 1.000 1.000Resolution: Resolution: 0.010 (100 points) 0.010 (100 points)
in -0.4 -0.2 0.0 0.2 0.4
in 0
.4
0.3
0
.2
0.1
0
.0
-0.1
-0
.2
-0.3
-0
.4
-0.5
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS225ARi CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
3.750"
2.000"
DATE: 06/27/2003
ø0.7
50"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XXXX: +/- 0.001".XX: +/- 0.010"
.XXX: +/- 0.003"
MATERIAL: 2017 ALUMINUM
NOTE: SERIALIZE PER P.O.
FINISH: BLUE ANODIZED
ø1.4
75"
QMI, INC. AIRSCAN RECEIVER MODEL: AS225ARi SERIAL: XXXX
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
DRAWING NUMBER: NA0306008
TITLE: CONFIG, AS225ARiSCALE: NONE
REV: 1
QMI, INC.
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS225ARiSerial Number: REFERENCETransducer Type: Airscan ReceiverFrequency: 225kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AN38NIST Report.: 1202042Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 12.5uJGain (dB): 20Attenuation (dB): 41.4H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 24.5
Pulse Frequency
usec 270 275 280 285 290 295
% 1
00
50
0
-50
-100
MHz 0.1 0.2 0.3 0.4
% 0
.8
0.6
0
.4
0.2
Pulse Results Frequency Results
Pulse Width @ -6dB: 1.242 usec Peak Frequency: 0.264 MHzPulse Width @ -20dB: 1.866 usec Center Frequency: 0.240 MHzPeak to Peak Amplitude:168.408 % Low Frequency @ -3dB: 0.216 MHz
High Frequency @ -3dB: 0.260 MHzBandwidth @ -3dB: 18.564 %Low Frequency @ -6dB: 0.208 MHzHigh Frequency @ -6dB: 0.271 MHzBandwidth @ -6dB: 26.541 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS225ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS225ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -0.750 0.000Length: Length: 1.500 100.000Resolution: Resolution: 0.010 (150 points) 0.024 (4096 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS225ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.010 (150 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS225ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.010 (150 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS225ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 -0.750Length: Length: 1.500 1.500Resolution: Resolution: 0.010 (150 points) 0.010 (150 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
in 0
.6
0.4
0
.2
0.0
-0
.2
-0.4
-0
.6
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS225Ti CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
3.750"
2.000"
DATE: 06/27/2003
ø0.7
50"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XXXX: +/- 0.001".XX: +/- 0.010"
.XXX: +/- 0.003"
MATERIAL: 2017 ALUMINUM
NOTE: SERIALIZE PER P.O.
FINISH: BLUE ANODIZED
ø1.4
75"
QMI, INC.AIRSCAN TRANSMITTER MODEL: AS225Ti SERIAL: XXXX
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
DRAWING NUMBER: NA0306007
TITLE: CONFIG, AS225TiSCALE: NONE
REV: 1
QMI, INC.
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS225TiSerial Number: REFERENCETransducer Type: Airscan TransmitterFrequency: 225kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AN38NIST Report.: 1202042Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 100uJGain (dB): 40Attenuation (dB): 13.2H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 72.7
Pulse Frequency
usec 100 110 120 130 140
% 1
00
50
0
-50
-100
MHz 0.1 0.2 0.3 0.4
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 1.351 usec Peak Frequency: 0.237 MHzPulse Width @ -20dB: 2.052 usec Center Frequency: 0.227 MHzPeak to Peak Amplitude:187.939 % Low Frequency @ -3dB: 0.208 MHz
High Frequency @ -3dB: 0.243 MHzBandwidth @ -3dB: 15.439 %Low Frequency @ -6dB: 0.202 MHzHigh Frequency @ -6dB: 0.251 MHzBandwidth @ -6dB: 21.710 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS225Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS225Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -0.750 0.000Length: Length: 1.500 100.000Resolution: Resolution: 0.010 (150 points) 0.024 (4096 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS225Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.010 (150 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS225Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.010 (150 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS225Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 -0.750Length: Length: 1.500 1.500Resolution: Resolution: 0.010 (150 points) 0.010 (150 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
in 0
.6
0.4
0
.2
0.0
-0
.2
-0.4
-0
.6
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS120ARiSerial Number: REFERENCETransducer Type: Airscan ReceiverFrequency: 120kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AS11NIST Report.: 1207003Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 100ohmEnergy: 12.5uJGain (dB): 20Attenuation (dB): 59.7H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 6.2
Pulse Frequency
usec 260 270 280 290 300 310 320
% 1
00
50
0
-50
-100
MHz 0.05 0.10 0.15 0.20
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 2.243 usec Peak Frequency: 0.141 MHzPulse Width @ -20dB: 3.209 usec Center Frequency: 0.129 MHzPeak to Peak Amplitude:189.697 % Low Frequency @ -3dB: 0.118 MHz
High Frequency @ -3dB: 0.140 MHzBandwidth @ -3dB: 16.907 %Low Frequency @ -6dB: 0.114 MHzHigh Frequency @ -6dB: 0.143 MHzBandwidth @ -6dB: 22.263 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS120ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS120ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -0.750 0.000Length: Length: 1.500 100.000Resolution: Resolution: 0.020 (75 points) 0.024 (4096 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS120ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.020 (75 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS120ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.020 (75 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS120ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 -0.750Length: Length: 1.500 1.500Resolution: Resolution: 0.020 (75 points) 0.020 (75 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
in 0
.6
0.4
0
.2
0.0
-0
.2
-0.4
-0
.6
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS120Ti CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
3.750"
2.000"
DATE: 06/27/2003
ø0.7
50"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XXXX: +/- 0.001".XX: +/- 0.010"
.XXX: +/- 0.003"
MATERIAL: 2017 ALUMINUM
NOTE: SERIALIZE PER P.O.
FINISH: BLUE ANODIZED
ø1.4
75"
QMI, INC.AIRSCAN TRANSMITTER MODEL: AS120Ti SERIAL: XXXX
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
DRAWING NUMBER: NA0306005TITLE: CONFIG, AS120TiSCALE: NONE
REV: 1
QMI, INC.
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS120TiSerial Number: REFERENCETransducer Type: Airscan TransmitterFrequency: 120kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AS11NIST Report.: 1207003Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 100uJGain (dB): 40Attenuation (dB): 16.4H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 69.5
Pulse Frequency
usec 160 170 180 190 200 210 220 230
% 1
00
50
0
-50
-100
MHz 0.05 0.10 0.15 0.20
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 2.679 usec Peak Frequency: 0.140 MHzPulse Width @ -20dB: 3.776 usec Center Frequency: 0.128 MHzPeak to Peak Amplitude:195.508 % Low Frequency @ -3dB: 0.117 MHz
High Frequency @ -3dB: 0.139 MHzBandwidth @ -3dB: 16.827 %Low Frequency @ -6dB: 0.114 MHzHigh Frequency @ -6dB: 0.143 MHzBandwidth @ -6dB: 22.321 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS120Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS120Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -0.750 0.000Length: Length: 1.500 100.000Resolution: Resolution: 0.020 (75 points) 0.024 (4096 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS120Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.020 (75 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS120Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 0.000Length: Length: 1.500 5.000Resolution: Resolution: 0.020 (75 points) 0.040 (125 points)
in 0
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS120Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -0.750 -0.750Length: Length: 1.500 1.500Resolution: Resolution: 0.020 (75 points) 0.020 (75 points)
in -0.6 -0.4 -0.2 -0.0 0.2 0.4 0.6
in 0
.6
0.4
0
.2
0.0
-0
.2
-0.4
-0
.6
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS50ARi CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
5.000"
DATE: 06/27/2003
ø0.7
50"
2.000"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XXXX: +/- 0.001".XX: +/- 0.010"
.XXX: +/- 0.003"
MATERIAL: 2017 ALUMINUM
PLATING: HARD ANODIZE PER PO
FINISH: #16
ø2.8
7 5"
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
DRAWING NUMBER: NA0306001TITLE: CONFIG, AS50ASCALE: NONE
REV: 1
QMI, INC.
2.125"
QMI, INC. AIRSCAN RECEIVER MODEL: AS50Ti SERIAL: XXXX
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS50ARiSerial Number: REFERENCETransducer Type: Airscan ReceiverFrequency: 50kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AR01NIST Report.: 1202029Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 100uJGain (dB): 40Attenuation (dB): 12.9H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 73
Pulse Frequency
usec 150 200 250 300
% 1
00
50
0
-50
-100
MHz 0.02 0.04 0.06 0.08
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 5.942 usec Peak Frequency: 0.052 MHzPulse Width @ -20dB: 9.774 usec Center Frequency: 0.056 MHzPeak to Peak Amplitude:199.951 % Low Frequency @ -3dB: 0.039 MHz
High Frequency @ -3dB: 0.063 MHzBandwidth @ -3dB: 48.340 %Low Frequency @ -6dB: 0.038 MHzHigh Frequency @ -6dB: 0.074 MHzBandwidth @ -6dB: 65.039 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS50ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 7.040 100.000Resolution: Resolution: 0.080 (88 points) 0.024 (4096 points)
in 0 1 2 3 4 5 6 7
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS50ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -1.500 0.000Length: Length: 3.000 100.000Resolution: Resolution: 0.040 (75 points) 0.024 (4096 points)
in -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS50ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -1.500 0.000Length: Length: 3.000 7.040Resolution: Resolution: 0.040 (75 points) 0.080 (88 points)
in -1 0 1
in 7
6
5
4
3
2
1
0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS50ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -1.500 0.000Length: Length: 3.000 7.040Resolution: Resolution: 0.040 (75 points) 0.080 (88 points)
in -1 0 1
in 7
6
5
4
3
2
1
0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS50ARi
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -1.500 -1.500Length: Length: 3.000 3.000Resolution: Resolution: 0.040 (75 points) 0.040 (75 points)
in -1.5 -1.0 -0.5 0.0 0.5 1.0
in 1
.0
0.5
0
.0
-0.5
-1
.0
-1.5
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QUALITY MATERIAL INSPECTION INC, 5442 Oceanus Drive, Huntington Beach, CA 92649, USA. Phone: 714.903.4500 www.qmi-inc.com
AS50Ti CONFIGURATION DRAWING
DRAWN BY: NORM ARMSTRONG
5.000"
DATE: 06/27/2003
ø0.7
50"
2.000"
DEGREES: +/- 3°
TOLERANCE (UNLESS OTHERWISE NOTED)
.XXXX: +/- 0.001".XX: +/- 0.010"
.XXX: +/- 0.003"
MATERIAL: 2017 ALUMINUM
PLATING: HARD ANODIZE PER PO
FINISH: #16
ø2.8
7 5"
919 SUNSET DRIVE, COSTA MESA, CA 92627 (714) 631-7672
DRAWING NUMBER: NA0306002TITLE: CONFIG, AS50TSCALE: NONE
REV: 1
QMI, INC.
2.125"
QMI, INC.AIRSCAN TRANSMITTER MODEL: AS50Ti SERIAL: XXXX
QMIFN-1104: Transducer Characterization
Certification Data
Cert. Number:Cert Date:Cert. Validity:Customer:P.O. Number:TRANSDUCER DATA:Manufacturer: QMIModel Number: AS50TiSerial Number: REFERENCETransducer Type: Airscan TransmitterFrequency: 50kHz
Inspection Instrumentation
Pulser: Panametrics 5800Pulser S/N: 95041812NIST Report.: 32141Data Acq.: QMI MC-DAQData Acq. S/N: 0612001NIST Report.: 1888Scanner Model: UPK IIBScanner S/N: 1600204611NIST Report.: 1848-AReference TX: AS11NIST Report.: 1207003Cable: 6ft. 50ohm
Pulser/Receiver Settings
Damping: 500ohmEnergy: 100uJGain (dB): 40Attenuation (dB): 12.4H. P. filter: 1kHzL. P. filter: 5MHzSensitivity (-dB): 73.5
Pulse Frequency
usec 300 320 340 360 380 400 420 440
% 1
00
50
0
-50
-100
MHz 0.02 0.04 0.06 0.08
% 1
.0
0.8
0
.6
0.4
0
.2
0.0
Pulse Results Frequency Results
Pulse Width @ -6dB: 6.425 usec Peak Frequency: 0.055 MHzPulse Width @ -20dB: 8.999 usec Center Frequency: 0.051 MHzPeak to Peak Amplitude:198.730 % Low Frequency @ -3dB: 0.039 MHz
High Frequency @ -3dB: 0.063 MHzBandwidth @ -3dB: 47.983 %Low Frequency @ -6dB: 0.038 MHzHigh Frequency @ -6dB: 0.064 MHzBandwidth @ -6dB: 51.981 %
Documented by:
Measurements per ASTM E-1065-99 with instruments traceable to NIST in accordance with ANSI/NCSL Z540-1.
QMIFN-1104: Transducer CharacterizationAS50Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: 0.000 0.000Length: Length: 5.000 100.000Resolution: Resolution: 0.040 (125 points) 0.024 (4096 points)
in 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS50Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (%) Start: Start: -1.500 0.000Length: Length: 3.000 100.000Resolution: Resolution: 0.040 (75 points) 0.024 (4096 points)
in -1.5 -1.0 -0.5 0.0 0.5 1.0 1.5
% 1
00
90
80
70
60
50
40
30
20
10
0
QMIFN-1104: Transducer CharacterizationAS50Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -1.500 0.000Length: Length: 3.000 5.000Resolution: Resolution: 0.040 (75 points) 0.040 (125 points)
in -1 0 1
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS50Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -1.500 0.000Length: Length: 3.000 5.000Resolution: Resolution: 0.040 (75 points) 0.040 (125 points)
in -1 0 1
in 5
.0
4.5
4
.0
3.5
3
.0
2.5
2
.0
1.5
1
.0
0.5
0
.0
-100 -80 -60 -40 -20 0 20 40 60 80 100 %
QMIFN-1104: Transducer CharacterizationAS50Ti
HORIZONTAL AXIS (in) VERTICAL AXIS (in) Start: Start: -1.500 -1.500Length: Length: 3.000 3.000Resolution: Resolution: 0.040 (75 points) 0.040 (75 points)
in -1.5 -1.0 -0.5 0.0 0.5 1.0
in 1
.0
0.5
0
.0
-0.5
-1
.0
-1.5
-100 -80 -60 -40 -20 0 20 40 60 80 100 %