alcadon ab - rapidnet fibre · 2008. 4. 10. · • flammability (vertical burn) to iec 332 part 1...
TRANSCRIPT
RapidNet
Ref:LD050
Fibre
RapidNet fibre is a pre-terminated “plug & play” solution which doesn’t require on site termination and testing, the mostlabour intensive aspect of any installation. This dramatically reduces installation time.
RapidNet fibre cassettes present 12 factory terminated and tested LC connections with each LC connector machine polishedto ensure the insertion loss is kept to a minimum. Each RapidNet fibre cassette is inserted into a 1U metal blank patch panelthat has 4 rectangular openings offering 48 LC connections per 1U panel.
The RapidNet fibre optic cable contain fibres with Tetracoat® protection, non metallic aramid strength members(incorporating a moisture protection system) and a flame retardant LSOH® (Low Smoke Zero Halogen) sheath. (RapidNetfibre is only available in tight buffered cable)
• Save up to 85% installation time on site
• Guaranteed high quality pre-termination thanks toHellermannTyton’s pre-testing
• Clean installation with minimal disruption
• Better programme management possible
• LSOH® is attractive where the generation of smoke ortoxic emissions is potentially hazardous to people orequipment
• Fibre type – singlemode (9/125µm) or multimode(50/125 or 62.5/125µm) OM1, OM2, OM3.
• Sheath colour – black as standard.
When installed by an approved and authorisedHellermannTyton installer, the entire system is fullysupported by HellermannTyton’s comprehensive 25 YearSystem Guarantee which covers all components includedwithin the system and the overall performance and dataintegrity of the system during the life of the warranty.HellermannTyton terms and conditions apply.
Features and Benefits Warranty
Options
Hel lermannTyton Data Ltd 43-45 Sa l thouse Road Cornwe l l Bus iness Pa rk B rackmi l l s Nor thampton NN4 7EXT e l : + 4 4 ( 0 ) 1 6 0 4 7 0 7 4 2 0 F a x : + 4 4 ( 0 ) 1 6 0 4 7 0 5 4 5 4 W e b : w w w . h t d a t a . c o . u k E - m a i l s a l e s @ h t d a t a . c o . u k
Sequentiallength mark
Week & yearof manufacture
Printing
RapidNet Fibre only available in Black (LSOH).
Fibre colours
• IEC 60793 & IEC 60794-2
• Flammability (Vertical Burn) to IEC 332 Part 1 (BS 4066 Part 1).
• Flammability (Ladder Burn) to IEC 332 Part 3 (BS 4066 Part 3).
• Smoke Emission to IEC 1034 & BS 6853 Appendix B.
Applicable Standards
Product Codes
RNF 12 LC OM3 PP 'X' M Code Description
'X' M Length in metres
PP Panel-to-Panel
62.5/125 Multimode Fibre
50/125 Multimode Fibre
OM3 Multimode Fibre
9/125 Singlemode Fibre
LC LC Fibre presentation
12 12 way cassette Fibre
RNF RapidNet Fibre series
Fibre count 12
Cable Dia. (mm)
Tensile operational 800
Tensile install 1200
Bend dia. (mm) operational 120
Bend dia. (mm) install 240
Weight (kg/km) dependent on length
Operational Installation Storage
-004004)mc/N(hsurC
Temperature -25 + 70 - -40 +70
Product References & Technical Information
Fibre type(eg 50, 62.5)
The sheath is marked at metre intervals:
8.0 nominal