aldehyds efficient...consumption of disinfectant 2-4 ml / m³ size of space up to 270 m² (larger...
TRANSCRIPT
www.oxytechsolutions.com
amicrobic safe clean
NORO efficient
Free of
AldehydsAlcoholeChorinePentolQuats
OxytechGenerator PROTECBio-Decontamination of Rooms, Surfaces and Inventory by Aerosol-Fogging-Techno-logy with H2O2
Made in Germany
www.oxytechsolutions.com
eco friendly2
Overview Advantages:
Mobile, electronic V2A-Device for Room and Surface Disinfection.
•High-performance bio- decontamination of rooms, surfaces and inventory without gaps
•Environmentally friendly and free of any residues
•Material tolerance including highly sensitive electronics
•User-friendly disinfection by lightweight mo-bility and ergonomic design of the device
•VerifiedbyrenownedbacteriologistandVi-rologists in FTEs processes
•Dust binding decontamination technology
•Modern nebulization technology enables neutralhygienecertificatefromthehospitalhygienist
www.oxytechsolutions.com 3
Use in daily practice
• The implementation of fogging disin-fection with OxyProtection (= Oxytech Generator + Oxytech D50/500) neither requires a training as disinfector nor a fumigation licence according to TRGS 522nd.
• Any openings in the room free of peop-le are sealed off from the outside with tape.
• The disinfection system is positioned in a cor-ner about 1 meter from the walls, depending on room conditions.
• The nozzle of the generator shows in diagonal di-rection of the space.
• After placement of the system and calculation of the space volume, the disinfection process can be star-ted,(withalargerproportionofglassm3andasignifi-cant contamination, higher values need to be set).
• The user has to leave the room 30 seconds after switching the device on.
• The fully automatic decontamination is completed after 90 minutes without remaining residues, and the occupational exposure limit and the H2O2 concentration in the air is in „green“ range (<1.0 ppm).
www.oxytechsolutions.com
1. Equipment and room preparationInthefirstphaseoftheprocessthedecontaminatingareaispreparedbyremovingnon-compliant fogging items (for example, plants, oxidizing materials, etc.) from the room. The generator is placed in accordance to the instructions.
2. Fumigation / cold foggingBy nebulization of Oxytech Aerosol area-disinfectants, Hydrogen peroxide is converted intoagasphase,andthroughthejetssystembyveryfineaerosolsevenlydistributedin room.
3. Impact timeThe impact time of the disinfection process begins as soon as the appropriate concen-tration of H2O2 is reached. With setting of 270 m3 the impact time starts after about 15 minutes, that means, directly after the process time (nebulization) or saturation of the space. Parallel to the impact time, the degradation of Hydrogen peroxide occurs in the ambient air (see chart).
4. Degradation / ventilationAfter expiration of the impact time, H2O2 degrades into water and oxygen. By atomi-zation of Oxytech Aerosol in higher concentrations (>5%) the degradation process can be accelerated by complementary measures (eg by switching on the ventilation, or opening of windows and doors)
4
Phases of fogging disinfectant
Phases of Bio-Decontermitation Cyclus
H2O
2 co
nten
t in
the
air
preparation process time impact time + parallel reduction of concentration
cycle time
www.oxytechsolutions.com
Technical DatesMeasures/ Size 800 x 390 x 300 mm (H x W x D)Housing / Jets Stainless SteelTension 30 kg without disinfectantFrequence 50 / 60 HzConsumption 350 WPower Cable 2 mCompressor dry air compressor without oilOperating Parameters
Environment Temperature 13° C to 33°° Crel. Humidity Up to appr. 85%max. filling Volume 5 liter containersConsumption of Disinfectant 2-4 ml / m³Size of Space up to 270 m² (larger volumes possible On demand)Level of Noise 62 dB
Oxytech Aerosol H2O2• Special hydrogen peroxide formula with silver
complex in different standard concentrations (depending on scope and contamination: 3%, 8%, 12% and 19%)
• For biocompatible disinfection of rooms, areas and inventory by three-dimensional disinfection using OxytechGenerator PROTEC
• Safety use of biocides: always read the label, and product safety data sheet.
5
Technical Dates
Equipment
Handy Laser Distance Measuring Equipment to determine the Room volume (m3)
Hydrogen peroxide test strips for nebulization detection
Contact Plates for micro-biological determination of disinfection success
Mobile data logger for documentation of main disinfection parameters
www.oxytechsolutions.com 6
Disinfectant Aerosol 3 Disinfectant Aerosol 8
Disinfectant Aerosol 12 Disinfectant Aerosol 19
For ongoing infec-tion prevention in hospitals, nursing homes, ambulance etc.
For ongoing infection preven-tion and mold control.
For ongoing infection pre-vention and Noro viruses control.
Disinfectant for Deconta-mination of Rooms
All Oxytech Aerosol disinfectants are avaliable as standard in 1-liter bottles and in the 5 -liter canisters.
To combat mold, and Noro vi-ruses and crime scene cleaning.
www.oxytechsolutions.com
Generator - Standard
Generator - Pharma
Generator - MF Multi FunctionGenerator - Protec Tube
7
Mobile, white painted device for the automatic space and surface disin-fection.
Portable, white painted V2A device with removable hose and coupling.
Mobile V2A device for bio-decontamination of clean rooms in the pharmaceuti-cal industry
Mobile V2A device with re-movable hose and coupling.
Other disinfection generatorsFind out more about disinfection systems by Oxytech. All systems aremicro biologically tested as unit with Oxytech Aerosol products.
Oxytech Generators