EMROL – Your power partner
Support Support –– Part one Part one
� What is and how to use / upgrade the software /firmware / manual
� How to start a capacity test
� Interpreting the results after a test is finished
� Read out the results with the BITS-software
� Create and print a test report with added details +remarks.
EMROL – Your power partner
BITS - softwareBITS - software
� Windows program for interfacing with the device
� Upgrades available on the Emrol website
� Upgrading with Special update interface (to bereleased)
� Available in English only
EMROL – Your power partner
FirmwareFirmware
� Firmware is program code in the device.
� Upgrades available with the download tool in BITS.
� Simple click for uploading.
� Some new functions in the software will require anupdate of the firmware.
EMROL – Your power partner
The ManualThe Manual
� HTML format: Cross platform, easy to print, easyfor searching
� Upgrades available on the Emrol website
� Available in different languages (to come)
� These will be available from the installation CDand website.
EMROL – Your power partner
How to start a capacityHow to start a capacity
testtest� Initial Setting: Battery testing only (without useof profiles)
� Connect to the battery
� Enter the Capacity using the + and – keys
� Press Enter � test will start
EMROL – Your power partner
What is the meaning ofWhat is the meaning of
the resultsthe results� Result in percent
� Passed
� Failed
� BadCell
� End user
� ShutDown
� Capacity
� Recharge
� (Charge F - > see part two)
EMROL – Your power partner
Creation of aCreation of a
professional reportprofessional report� Transfer the results (Raw Data) to the PC
� Add details (customer specs, battery &manufacturing reference, ...)
� Remarks
� Print out
EMROL – Your power partner
RegistrationRegistration
� Software is licensed - One license needed percomputer
� One free license included with AlfaBat
� Full support, if registered
� Possible to buy extra licenses
� Without registration: printing and some file -operations get disabled after one month
EMROL – Your power partner
Support Support –– Part two Part two
� What are profiles and an explanation of theparameters
� How to improve the accuracy of a capacity test
� Charger and cycle test on a battery
� Use of monitor test
� The possibility of recording data in a system with aload/source on a battery
� Can the AlfaBat break down, how can you test it(tools and technical manual) and how can you fixit (spare parts + instructions)
EMROL – Your power partner
ProfilesProfiles
� What are profiles? What are parameters?
� 3 profiles in the AlfaBat, Unlimited on the PC
� How to use them?
� Always use the same profile or choose to selectone
� Upload to device
EMROL – Your power partner
Profile ParametersProfile ParametersParameter Min Max Default
01: Battery voltage autodetection ( 0 = Manual / 1 = Auto ) 0 1 102: Preselect battery voltage ( 00 = 6V / 01 = 8V / 11 = 12V ) 00 11 1103: Use Preset mode ( 0 = Automatic / 1 = Manual ) 0 1 104: Preset Mode ( 00 = discharge, 01 = charger test, 10 = cycle, 11 = record ) 00 11 0005: Record Voltage ( 0 = OFF, 1 = ON ) 0 1 106: Record Current ( 0 = OFF, 1 = ON ) 0 1 007: Printer output enable ( 0 = OFF, 1 = ON ) 0 1 008: Preset Capacity ( 0 = Manual, 0.8 - 100 Ah ) 0.8 100 20.0009: Capacity Unit ( 0 = Manual, 5 = C5, 10 = C10, 20 = C20 ) 5 20 010: Peukert Factor ( 0 = Manual, 1.10, 1.12, 1.14, .., 1.36 ) 1.10 1.36 1.2011: Peukert calculation test ( 0 = OFF / 1 = ON ) 0 1 012: Temperature ( 0 = Manual, 1 .. 127) 0 127 013: Temperature Unit ( 0 = °C, 1 = °F) 0 1 014: Maximum Charging Time / Recording Time ( 0 = Manual, 1 .. 99 hour ) 0 99 1215: Number of cycle in cycle mode ( 0 = Manual, 255 = Unlimited, 1 .. 254 ) 0 255 316: Offset (1/impedance) 0 255 2417: Bad Cell Timer in minutes ( 0 = Auto, 1..30 ) 0 30 018: Bad Cell Voltage High level ( 0 = Auto, 1.50V .. 2.55V ) 1.50 2.55 0.0019: Bad Cell Voltage Low level ( 0 = Auto, 1.50V .. 2.55V ) 1.50 2.55 0.0020: End of discharge voltage in Volt / element ( 0 = Auto, 1.51 .. 2.55 ) 1.51 2.55 0.0021: Needs charging voltage in Volt / element ( 0 = Auto, 1.51 .. 2.55 ) 1.51 2.55 0.0022: Pass / Fail Treshold in % ( 0 .. 100 ) 0 100 6023: Maximum discharge in % ( 0 = OFF / 1 .. 150 ) 0 150 024: Discharge current ( 0 = AUTO, 5 = 5A, 10 = 10A) 0.00 10.00 0.00
EMROL – Your power partner
ImprovImprovinging the accuracy the accuracy
� Correct battery temperature
� Battery quality � Peukert value
EMROL – Your power partner
PeukertPeukert
� Peukert capacity = capacity when dischargedwith one ampere
� Normal value = 1.10 to 1.36
� Ideal value = 1
� High values indicate poor battery quality
� AlfaBat has a function to determine this factor
EMROL – Your power partner
Charger and cycle testCharger and cycle test
on a batteryon a battery� Select a correct profile
� Adaptor is required
� Connect the charger
� Charger test: result in Ah � Usefull to record acharger’s regime.
� Cycle discharge: result in %
� Cycle charge: Charge factor
EMROL – Your power partner
Charge FactorCharge Factor
� Relation between the discharged capacity andthe charged capacity
� > 1.10 : to compensate charge losses you needto put more energy in a battery then what wasextracted.
EMROL – Your power partner
Monitor TestMonitor Test
� Online tracking of a test in progress
� Necessary during cycle test (unless printer isused)
� Needed for peukert calculation
� Alternative to cycle test with PC: use of theprinter
EMROL – Your power partner
Recording data in aRecording data in a
systemsystem� Connect the source/load to the charger port.Make sure the load respects the max current15A or 50A.
� Connect the battery to the battery port
� Start a recording test (use the correct profile)
EMROL – Your power partner
Technical solutionsTechnical solutions
� Simple things first: all connections are present,polarity ok, bad connection, latest firmware /software, ...
� Look in the knowledge base on the Emrolwebsite.
� If you are sure there is a technical problem �look in the technical manual
� Use the service tools to locate / fix the technicalproblem
EMROL – Your power partner
Technical Technical ManualManual
� Use ONLY original spare parts (FAN, Fuse,controller board, ...).
� Use one of the tools for testing the device incombination with the Windows software.