all parameter-new
TRANSCRIPT
-
7/30/2019 All Parameter-new
1/97
6 Cell Selection / ReselectionSr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
Intra-Frequency Cell Reselection
1(Cell_selection_and_reselection_quality_measure) -Choice of measurement (CPICH Ec/No or CPICH RSCP) to use as
quality measurement value Q for FDD Cells.
1: CPICH Ec/No
2: CPICH RSCP
2(Qqualmin)-Minimum required quality level in the Cell expressed in terms of
CPICH Ec/No in dB.
(-24..0)dB step 1dB
3(Qrxlevmin)- Minimumrequired RX level in the Cell expressed in terms of CPICH RSCP in
dBm.
(-115..-25)dBm step 2dB
4(UE_TXPWR_MAX_RACH)- Maximum
allowed UL TX power for the serving Cell(-50..33)dBm, step 1dB
7
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
5(Sintrasearch) -Defines Cell signal strength quality beyond which intra-
frequency Cell search for reselection should be pursued.
(0..20 )dB Step 2dB
6(Qhyst1s ) -
Hysteresis value in the Cell ranking criteria for Cell
reselection when CPICH RSCP is used.
(0..40)dB step 2 dB
7(Qhyst2 s) -
Hysteresis value in the Cell ranking criteria for Cell
reselection when CPICH Ec/No is used.
(0..40)dB step 2 dB
8
(Qhyst1s ,PCH) -
When used, is Hysteresis value in equation used by UE to
calculate Cell ranking of the serving Cell for UEs in
Cell_PCH or URA_PCH RRC state. Uses CPICH RSCP.
(0..40)dB step 1dB
9
(Qhyst2 s,PCH) -When used, is Hysteresis value in equation used by UE to
calculate Cell ranking of the serving Cell for UEs in
Cell_PCH or URA_PCH RRC state. Uses CPICH Ec/No.
(0..40)dB step 1dB
10
(Qhyst1 s ,FACH) -
Hysteresis value in equation used by UE to calculate Cell
ranking of the serving Cell for UEs in Cell_FACH RRC state.
Uses CPICH RSCP.
(0..40)dB step 1dB
11
(Qhyst2 s ,FACH) -
Hysteresis value in equation used by UE to calculate Cell
ranking of the serving Cell for UEs in Cell_FACH RRC state.
Uses CPICH Ec/No.
(0..40)dB step 1dB
12
(Qoffset1s,n) -
Offset between 2 Cells when the quality measure for Cellselection and reselection is set to CPICH RSCP.
(-50..50)dB setp 1dB
13(Qoffset2s,n) -
Offset between 2 Cells when the quality measure for Cell
selection and reselection is set to CPICH Ec/No
(-50..50)dB step 1dB
14(Treselections) -
This parameter specifies the Cell reselection timer value.(0..31)s step 1s
8
-
7/30/2019 All Parameter-new
2/97
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
15(Treselections,PCH) -
Additional Cell reselection timer value to be used for UEs in
Cell_PCH or URA_PCH.
(0..31)s step 1s
16(Treselections,FACH) -
Additional Cell reselection timer value to be used for UEs in
Cell_FACH or URA_FACH.
(0..6.2)s step 0.2 s
17
Scaling factor used for UEs that are very mobile; when high
mobility is detected, it is a multiplier on the Treselection(0..1) step 0.1
Inter-Frequency Cell Reselection
18(Sintersearch) -
Defines Cell signal strength quality beyond which inter-
frequency Cell search for reselection should be pursued.
(0..20 )dB Step 2dB
19
(Inter-frequency ScalingFactor for Treselection)
Scaling factor used for UEs that are very mobile; for inter-
frequency Cells when high mobility is detected, it is a
multiplier on the Treselection variable.
(1..4.75) step 0.25
Inter-RAT Cell Reselection
20(Ssearch,RAT) -
Defines Cell signal strength quality beyond which inter-RAT
Cell search for reselection should be pursued
(0..20 )dB Step 2dB
21
(Inter-RAT ScalingFactor for Treselection)
Scaling factor used for UEs that are very mobile; for inter-
RAT Cells when high mobility is detected, it is a multiplier on
the Treselection variable.
(1..4.75) step 0.25
GSM to WCDMA Cell Reselection
22
(Qsearc h_I) -
Defines a threshold and also indicates whether these
measurements shall be performed when RLA_C (running
average of received signal level) of the serving Cell is below
or above the threshold
(Never, -98..-54, always)
dBm step 4 dB between -
98 dBm and -54 dBm
23(FDD_Qmin ) -
Defines minimum Ec/No must be >= to for UE to reselect
UMTS FDD Cell
(-20..-12) dB step 1 dB
9
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
(FDD_Qoffs et) -
Applies an offset to RLA_C for Cell re selection to access
technology/mode FDD
(Always, -28..28) dB
step 4dB
HCS Cell Reselection
24(Use of HCS) -
Indicates whether Hierarchical Cell Structure is used and
defines associated rules for Cell reselection
0: False1: True
25(SsearchHCS) -
Defines Cell signal strength Srxlev beyond which HCS Cell
search for reselection should be pursued
(1..91)dB step2dB
26(TCRmax ) -
Timer for establishing duration for evaluating allowed amount
of Cell reselections
(Not Used, 30, 60, 120,
180, 240)s
-
7/30/2019 All Parameter-new
3/97
27(NCR) -
Number of Cell reselections associated with TCRmax for
establishing high mobility rate
(1..16) step 1
28(TCRmaxHyst) -
Timeframe for mobile to remain in high mobility mode before
returning to low-mobility measurements
(Not Used, 10, 20, 30,
40, 50, 60, 70)s
29(SHCS,RAT) -
Threshold for HCS Cell reselection measurement rules that
specifies RAT specific threshold
(1..91)dB step 2dB
30
(Slimit,SearchRA Tm) -
RAT specific threshold (in dB) for HCS Cell reselection in the
serving UTRA Cell above which the UE need not perform
any inter-RAT measurements
(0..20 )dB step2dB
31
ena y_ me -
When used for HCS, is used in the quality level threshold
calculation or Cell ranking calculation (whichever is used) as
the time duration to apply the Temporary_Offset to
(Not Used,10, 20, 30,
40, 50, 60 )s
32
_ -
When used for HCS, is used in the quality level threshold
calculation when using CPICH RSCP for Cell (re)-selection
(3, 6, 9, 12, 15, 18, 21,
inf) dB
10
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
33
_ -
When used for HCS, is used in the quality level threshold
calculation when using CPICH Ec/No for Cell (re)-selection
(2, 3, 4, 6, 8, 10, 12, inf)
dB
34(HCS_PRIOn,s)
HCS priority level for serving (s) or neighbor Cell (n); set
these as different values to arrange hierarchical priority
(0..7) step 1
35
(Qhcsn ,s) -
Quality threshold levels to apply to prioritized hierarchical
Cell reselection for serving (s) or neighbor Cell (n) when the
HCS_PRIO values differ for serving and neighbor Cells
(-110..-37) dBm step
1dB
36
(DeltaQhcs-RSCP)
Used conditionally when Qhcs is based on CPICH RSCP
and the value of the RSCP is below 0 (-115 dB); when used,
Qhcs = Qhcs + DeltaQhcs-RSCP
(-5..-1)dB step 1dB
11 Paging / Access
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
Directed Retry
1Directed Retry to GSM
Enables or disables the Directed Retry to GSM Feature.
0: Disabled
1: Enabled
2
Directed Retry to GSM Neighbor
Defines the GSM neighbor for Directed Retry.
Defined in GSM
neighbor list
3
Directed Retry to GSM Threshold
DL Power threshold that triggers a Directed Retry to GSM
(value relative to total available DL power).
(0..100)% step 1%
4
RABs A l lowed for Directed Retry to GSM
This parameter outlines the definition of what services qualify
for redirection (i.e., 12.2k AMR, PS Background, etc.)
No need, because only
AMR is allowed in 3GPP
Specs..
Load Sharing
5
Enables or disables the Inter-frequency Load Sharing0: Disabled
1: Enabled
-
7/30/2019 All Parameter-new
4/97
6Load Sharing Neighbor
Defines the UTRAN neighbor for Load Sharing.
Defined in UTRAN
neighbor list
7
Load Sharing Threshold
DL Power threshold that triggers a Load Sharing (value
relative to total available DL power).
(0..100)% step 1%
12
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
Access
8
-
Power per transmitted Acquisition Indicator, AP Acquisition
Indicator, or CD/CA Indicator minus power of the Primary(-22..5)dB step 1dB
9
(AICH Transmission Timing) -
Defines number of bits and Access Slots to be used for
distance between PRACH and AICH.
(0, 1)
10
-
Used by the UE to calculate the initial output power on
PRACH according to the Open loop power control(-35..-10)dB step 1dB
11(Power Ramp Step) -
Power step when no acquisition indicator is received.
(1..8)dB step 1dB
12
- -
In dB; Power offset between the last transmitted preamble
and the control part of the message (added to the preamble
power to receive the power of the message control part);
(-5..10)dB step 1dB
13
-
Maximum number of preambles in one preamble ramping (1..64) step 1
14(Mmax) -
Maximum number of preamble cycles.(1..32) step 1
15(NB01Min) -
Sets lower bound for random back-off.(0..50) step 1
16(NB01Max) -
Sets upper bound for random back-off.(0..50) step 1
17(Dynamic pers istenc e level) -Used to define persistence values to be used with Access
Service Class.
(1..8) step 1
18
(Persistence scaling fact or) -
Scaling factors corresponding to access service classes 2 -
7 applied to the dynamic persistence value.
(0.9..0.2) step 0.1
19
(Tbarred) -
Time value that UE is to consider a Cell barred in situations
where a Cell is barred.
(10,20,40,80,160,320,64
0,1280)s
20Power of UL DPCCH or control part of PRACH.
1..15 step 1
21Power of UL DPDCH or data part of PRACH.
1..15 step 1
13
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
-
7/30/2019 All Parameter-new
5/97
22(Access Class Barred List)
Allows access classes to be barred.
Bitstring(16)
Bit0 ~ bit9 correspond to
AC0~AC9, bit10~bit15
are reserved and take
the value of 1.
0: Barred
1: Not Barred
23(Domain Specific Access Class Barred List)
Allows access classes to be barred based on domain.
Bitstring(16)
Bit0 ~ bit9 correspond toAC0~AC9, bit10~bit15
are reserved and take
the value of 1.
0: Barred
1: Not Barred
Paging
24
(CS CN DRX Cycle Lengt h Coeffic ient) -
Individual time interval between monitoring Paging Occasion
specific to CS; The DRX cycle length for FDD = 2^k frames,
where k is the DRX cycle length coefficient.
(6..9) step 1
25
(PS CN DRX Cycle Lengt h Coeffic ient) -
Individual time interval between monitoring Paging Occasion
specific to PS; The DRX cycle length for FDD = 2^k frames,
where k is the DRX cycle length coefficient.
(6..9) step 1
26(UTRAN DRX Cycle Leng th Coeffic ient) -
DRX cycle length to be used for UEs.(3..9) step 1
27
(PICH Power Offset) -
Power transmitted on the PICH minus power of the Primary
CPICH.
(-10.. 5) dB step1 dB
28
(Number of PI per fram e (Np)) -
Used by UE to determine actual Paging Indicator within
Paging Occurrence that UE is monitoring.
183672144
29
(DRX cycle length coefficient)
Used by UE for determining paging interval for DRX. The
DRX cycle length for FDD = 2^k frames, where k is the DRX
cycle length coefficient.
(3..9) step 1
143.3
Power Control
Sr. No.
Parameter Name
(Specification Name/Term)
Description
Minimum Value/
Maximum Value/
Step Size (Units)
Downlink
1 Downl ink DPDCH power - ini t ial (-35..15 ) dB step 0.1 dB
2 PrimaryCpichPower(-10.0..50.0)dBm step
0.1dBm
3 cBackOff
4 Downlink DPDCH power minimum (-35..15 ) dB step 0.1 dB
5 Downl ink DPDCH power - maximumDefines the max power level for any RAB relative to pilot
(-35..15 ) dB step 0.1 dB
6Primary Synch Channel Power
Max power level of primary synch channel relative to pilot(-35..+15) dB step 0.1dB
7Secondary Synch Channel Power
Power level of secondary synch channel relative to pilot(-35..+15) dB step 0.1dB
8Bch Power
Power level of Broadcast control channel relative to pilot(-35..+15) dB step 0.1dB
-
7/30/2019 All Parameter-new
6/97
9
Secondary Common Control Channel Power
Max power level of secondary common control channel
relative to pilot
FACH (-35..+15) dB step
0.1dB
PCH (-35..+15) dB step
0.1dB
10Access Indication Channel Power
Max power level of Access Indication channel relative to pilot(-22..5)dB step 1dB
11Paging Indication Channel Power
Max power level of Paging Indication channel relative to pilot(-10.. 5) dB step1 dB
15
Sr. No.
Parameter Name
(Specification Name/Term)
Description
Minimum Value/
Maximum Value/
Step Size (Units)
12 (PO1) Downlink TFCI bit power offset relative to DPDCH (0..6) dB step 0.25 dB
-
7/30/2019 All Parameter-new
7/97
13(PO2)
Downlink TPC bit power offset relative to DPDCH(0..6) dB step 0.25 dB
-
7/30/2019 All Parameter-new
8/97
14(PO3)
Downlink pilot bit power offset relative to DPDCH(0..6) dB step 0.25 dB
15 Downlink DPCCH SIR target maximum (-35..15 ) dB step 0.1 dB
16 Downlink DPCCH SIR target minimum (-35..15 ) dB step 0.1 dB
17 Downlink DPCCH SIR target initial (-35..15 ) dB step 0.1 dB
18 Downl ink BL ER target (1..20) step 0.1
Uplink
-
7/30/2019 All Parameter-new
9/97
19 Uplink DPCCH SIR target maximum-8.2..17.3dB step
0.1 dB
-
7/30/2019 All Parameter-new
10/97
20 Uplink DPCCH SIR target minimum-8.2..17.3dB step
0.1 dB
-
7/30/2019 All Parameter-new
11/97
21 Uplink DPCCH SIR target initial-8.2..17.3dB step
0.1 dB
22
(DPCCH Power Offset)
Used by UE to set DPCH initial output power and to use for
closed-loop power control
(-164..-6) dB step 2 dB
23
(Maximum allowed UL TX power)
UE transmit power DCH maximum -50..33dBm step 1
24Power of UL DPCCH or control part of PRACH
1..15 step 1
25Power of UL DPDCH or data part of PRACH
1..15 step 1
26 Upl ink BLER target (1..20) step 0.1
16 soft handover
Sr. No.
Parameter Name
(Specification Name/Term)
Description
Minimum Value/
Maximum Value/
Step Size (Units)
Soft Handover
1 Active set size maximum (1..6) step 1
-
7/30/2019 All Parameter-new
12/97
2 (Maximum number of reported Cel ls on RACH) -
0: No Report
1: Current Cell
2: Current Cell + Best
Neighbour
3: Current Cell + 2 Best
Neighbours
..
7: Current Cell+6 Best
Neighbours
Intra Frequency Measurement Reporting Criteria
3
(Intra-Frequency Measurement Quanti ty)
Defines the measurement type for event 1a, 1b, 1c, 1d, 1e,
0: CPICH Ec/No
1: CPICH RSCP
4
(Event 1a Report ing rang e constant) -
Event 1a occurs when a Primary CPICH enters the
Reporting Range.
(0..14.5)dB step 0.5dB
5
Indicates the period of time during which the new Cell has to
be better than threshold before sending a Measurement
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
6
Weighting factor to control the proportion of the primaryCells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
(0.0..2.0) step 0.1
17
Sr. No.
Parameter Name
(Specification Name/Term)
Description
Minimum Value/
Maximum Value/
Step Size (Units)
7
(Event 1a Hysteresis)
To avoid excessive event-triggered measurement reports, a
hysteresis value can be associated with any of the Event 1
measurement reports to ensure that the threshold has
definitely been exceeded. However, this could have a
negative impact on the adds if the add is delayed too long!
(0..7.5)dB step 0.5dB
8(Event 1a Reporting interval)
Interval of periodic reporting when triggered by e1a event
, , , ,
2000, 4000, 8000,
9(Event 1a Amount of Reporting)
Amount of periodic reporting when triggered by e1a event.
(1, 2, 4, 8, 16, 32, 64,
Infinity)
10
(Event 1b Report ing range constant) -
Event 1b occurs when a Primary CPICH leaves the
Reporting Range.
(0..14.5)dB step 0.5dB
11
(Event 1b Time to trigger)
Indicates the period of time during which active Cell has to
be below threshold before sending a Measurement Report.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
12
(Event 1b W)
Weighting factor to control the proportion of the primary
Cells measured quantity and that of the remaining Cellsmeasured quantity in the active set. The results will be used
for event evaluation.
(0.0..2.0) step 0.1
13
(Event 1b Hysteresis)
Added amount to Active Cell removal threshold to ensure
that the threshold has definitely been exceeded.
(0..7.5)dB step 0.5dB
14(Event 1b Reporting interval)
Interval of periodic reporting when triggered by e1a event
, , , ,
2000, 4000, 8000,
15(Event 1b Amount of Reporting)
Amount of periodic reporting when triggered by e1c event.
(1, 2, 4, 8, 16, 32, 64,
Infinity)
-
7/30/2019 All Parameter-new
13/97
16
(Event 1c Time to trigger)
Indicates the period of time during which new Cell has to be
better than threshold and active Cell is below threshold
before sending a Measurement Report.
(0, 10, 20, 40, 60, 80,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
5000)ms
17(Event 1c Reporting interval)
Interval of periodic reporting when triggered by e1c event
, , , ,
2000, 4000, 8000,
18
Sr. No.
Parameter Name
(Specification Name/Term)
Description
Minimum Value/
Maximum Value/
Step Size (Units)
18(Event 1c Amount of Reporting)
Amount of periodic reporting when triggered by e1a event
(1, 2, 4, 8, 16, 32, 64,
Infinity)
19
(Event 1c Replacement activation threshold)
Indicates the minimum number of Cells allowed in the active
set in order for event 1c to occur.
0 means not applicable
(0, 1, 2, 3, 4, 5, 6, 7)
20
(Event 1c Hysteresis)
Added amount to Active Cell replacement threshold to
ensure that the threshold has definitely been exceeded.
(0..7.5)dB step 0.5dB
21
(Event 1c Time to trigger)
Indicates the period of time during which new Cell has to bebetter than threshold and active Cell is below threshold
before sending a Measurement Report.
(0, 10, 20, 40, 60, 80,
100, 120, 160, 200, 240,320, 640, 1280, 2560,
5000)ms
22(Event 1d Reporting interval)
Interval of periodic reporting when triggered by e1d event.
, , , ,
2000, 4000, 8000,
23
(Event 1d Hysteresis)
Added amount to Active Cell replacement threshold to
ensure that the threshold has definitely been exceeded.
(0..7.5)dB step 0.5dB
24
(Event 1d Time to trigger)
Indicates the period of time during which new Cell has to be
better than threshold before sending a Measurement Report.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
25
(Event 1e Threshold u sed frequency) -
Event 1e occurs when a Primary CPICH becomes better
than an absolute threshold.
- ..-
25) dBm
CPICH Ec/No: (-24..0)
dB
26
(Event 1e Time to trigger)
Indicates the period of time during which new Cell has to be
better than threshold before sending a Measurement Report.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
27
(Event 1e Hysteresis)
To avoid excessive event triggered measurement reports, a
hysteresis value can be associated with any of the Event 1
measurement reports to ensure that the threshold has
definitely been exceeded. However, this could have a
negative impact on adds if the add is delayed too long!
(0..7.5)dB step 0.5dB
19
Sr. No.
Parameter Name
(Specification Name/Term)Description
Minimum Value/
Maximum Value/Step Size (Units)
28
(Event 1f Threshold u sed frequency) -
Event 1f occurs when a CPICH becomes worse than an
absolute threshold.
- ..-
25) dBm
CPICH Ec/No: (-24..0)
dB
29
(Event 1f Time to trigger)
Indicates the period of time during which new Cell has to be
better than threshold before sending a Measurement Report.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
-
7/30/2019 All Parameter-new
14/97
30
(Event 1f Hysteresis)
To avoid excessive event triggered measurement reports, a
hysteresis value can be associated with any of the Event 1
measurement reports to ensure that the threshold has
definitely been exceeded. However, this could have a
negative impact on adds if the add is delayed too long!
(0..7.5)dB step 0.5dB
31
(Cel ls forbidden to affect report ing range) -
This parameter defines which Cells will not affect the
reporting range for Event 1a and Event 1b.
0 False
1 True
32(Cell indiv idual off set) -
Used to offset measured quantity value for FDD.(-10..10) dB step 0.5 dB
33
Neighbor List Pr ior i ty Level
This parameter allows the Cells neighbors to be ranked.
This is used when SHO conditions generate a composite NL
that may result in excessive neighbors being truncated.
0, 1, 2
34
Enable Missing Neighbo r Report ing -
This enables the RNC to log the scrambling code of Sites
that were reported (e.g., e1a, e1c, or e1d) but not on the
composite neighbor list.
0 Disabled
1 Enabled
20 Measurement Reporting Quantities
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
Intra-frequency Measurement Reporting Mode
1
Determines whether the UE issues these measurement
reports when certain events (e.g., event 1a) occur, or
Criteria
2: Periodical Reporting
Intra-frequency Measurement Reporting Quantities
2
Active Cell identity reporting enable Requires the UE to
include the identity of the active Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
3
Active Cell Ec/I0 reporting enable Requires the UE to
include the Ec/I0 of the active Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
4
c ve e repor ng ena e equ res e o
include the RSCP of the active Cells reported in a0: False (No Report)
1: True (Report)
5
Active Cell path loss reporting enable Requires the UE
to include the path loss to the active Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
21
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
6
Monitored Cell identity reporting enable Requires the
UE to include the identity of the monitored Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
7
Monitored Cell Ec/I0 reporting enable Requires the UE
to include the Ec/I0 of the monitored Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
8
Monitored Cell RSCP reporting enable Requires the UE
to include the RSCP of the monitored Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
9
Monitored Cell path loss reporting enable Requires the
UE to include the path loss to the monitored Cells reported in
a measurement report message.
0: False (No Report)
1: True (Report)
-
7/30/2019 All Parameter-new
15/97
10
Detected Cell identity reporting enable Requires the UE
to include the identity of the detected Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
11
Detected Cell Ec/I0 reporting enable Requires the UE to
include the Ec/I0 of the detected Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
12
Detected Cell RSCP reporting enable Requires the UE
to include the RSCP of the detected Cells reported in a
measurement report message.
0: False (No Report)
1: True (Report)
13
Detected Cell path loss reporting enable Requires the
UE to include the path loss to the detected Cells reported in
a measurement report message.
0: False (No Report)
1: True (Report)
22
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
Quality Measurement Reporting
14
Downlink BLER periodic reporting enable Requires the
UE to include the transport channel BLER in a periodic
measurement report message.
0: False (No Report)
1: True (Report)
15Downl ink B LER report ing interval -Determines how often
the UE reports the transport channel BLER.
(250, 500, 1000, 2000,3000, 4000, 6000, 8000,
12000, 16000, 20000,
24000, 28000, 32000,
64000) ms
16
Downlink SIR periodic reporting enable Requires the
UE to include the downlink SIR in a periodic measurement
report message.
No need, because SIR
measurement is only for
TDD.
17Downl ink SIR report ing interval -Determines how often
the UE reports its SIR.
No need, because SIR
measurement is only for
TDD.
UE Internal Measurement Reporting
23
Sr. No. Parameter Name DescriptionMinimum Value/Maximum Value/
Step Size (Units)
-
7/30/2019 All Parameter-new
16/97
18
(Event 4a Report ing Threshold) -
Threshold for UE to determine when to send Measurement
Report for event 4a indicating Transport Channel Traffic
volume has exceeded threshold.
(8, 16, 32, 64, 128, 256,
512, 1024, 2K, 3K, 4K,6K, 8K, 12K, 16K, 24K,
32K, 48K ,64K, 96K,
128K, 192K, 256K,
384K, 512K, 768K)
bytes
19
(Event 4a Time to Trigg er) -
Indicates the period of time during which the event condition
has to be satisfied, before sending a Measurement Report.
(0, 10, 20, 40, 60, 80,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
5000) ms
-
7/30/2019 All Parameter-new
17/97
20
(Event 4a Pending Tim e after Trigger) -
Period of time during which UE is forbidden to send any new
measurement reports with the same Traffic volume event
identity even if the triggering condition is fulfilled.
(250, 500, 1000, 2000,
4000, 8000, 16000) ms
21
(Event 4a Tx interru ption Time after Trigger) -
Indicates how long the UE shall block DTCH transmissions
on the RACH after a measurement report is triggered.
(250, 500, 1000, 2000,
4000, 8000, 16000) ms
24
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
22
(Event 4b Report ing Threshold) -
Threshold for UE to determine when to send Measurement
Report for event 4b indicating Transport Channel Traffic
volume has dropped below threshold.
(8, 16, 32, 64, 128, 256,
512, 1024, 2K, 3K, 4K,
6K, 8K, 12K, 16K, 24K,
32K, 48K ,64K, 96K,
128K, 192K, 256K,
384K, 512K, 768K)
bytes
-
7/30/2019 All Parameter-new
18/97
23
(Event 4b Time to Trig ger) -
Indicates the period of time during which the event condition
has to be satisfied, before sending a Measurement Report.
(0, 10, 20, 40, 60, 80,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
5000) ms
24
(Event 4b Pending Time after Trigger) -
Period of time during which UE is forbidden to send any new
measurement reports with the same Traffic volume event
identity even if the triggering condition is fulfilled.
(250, 500, 1000, 2000,
4000, 8000, 16000) ms
25
(Event 4b Tx interruptio n Time after Trigger) -
Indicates how long the UE shall block DTCH transmissions
on the RACH after a measurement report is triggered.
(250, 500, 1000, 2000,
4000, 8000, 16000) ms
25
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
26
Periodic (Reportin g Interval) -
How often periodic traffic volume messages should be sent if
Periodical reporting criteria IE is defined.
(250, 500, 1000, 2000,
3000, 4000, 6000, 8000,
12000, 16000, 20000,
24000, 28000, 32000,
64000)ms
-
7/30/2019 All Parameter-new
19/97
27 Periodic (Amount of reporting) (1, 2, 4, 8, 16, 32, 64,
Infinity)
28UE transmit power report ing interval -Determines how
often the UE reports its transmit power.
(250, 500, 1000, 2000,
3000, 4000, 6000, 8000,
12000, 16000, 20000,
24000, 28000, 32000,
64000)ms
29
(Event 6a UE Transm itted Power Tx power th reshold)
UE Transmitted Power becomes larger than an absolute
threshold.
(0..100)%
30
(Event 6a UE Time-to-tr igg er))
UE Transmitted Power becomes larger than an absolute
threshold.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
31
(Event 6b UE Transmitted Power Tx power threshold)
UE Transmitted Power becomes less than an absolute
threshold.
(0..100)%
26
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
32
(Event 6b UE Time-to-tr igger))
UE Transmitted Power becomes less than an absolute
threshold.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
33(Event 6c UE Time-to-tr igg er))
UE Transmitted Power reaches its minimum value.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
34(Event 6d UE Time-to-tr igger))
UE Transmitted Power reaches its maximum value.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
Cell Reporting Quantities
35 Cel l code power report ing over Iub
Ratio
1: SIR Error
2: Transmitted Code
Power
27
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
-
7/30/2019 All Parameter-new
20/97
36 Cel l total transmit p ower report ing over Iub
0: Received Total Wide
Band Power
1: Transmitted Carrier
Power
2: Acknowledged
PRACH Preambles
6: UTRAN GPS Timing
of Cell Frames for UE
Positioning8: Transmitted Carrier
Power of All Codes not
Used for HS-PDSCH or
HS-SCCH Transmission
9: HS-DSCH Required
Power
10: HS-DSCH Provided
Bit Rate
18: E-DCH Provided Bit
Rate
19: E-DCH Non-serving
Relative Grant Down
Commands
28
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
37 Cel l RTWP report ing over Iub
0: Received Total Wide
Band Power
1: Transmitted Carrier
Power
2: Acknowledged
PRACH Preambles
6: UTRAN GPS Timing
of Cell Frames for UEPositioning
8: Transmitted Carrier
Power of All Codes not
Used for HS-PDSCH or
HS-SCCH Transmission
9: HS-DSCH Required
Power
10: HS-DSCH Provided
Bit Rate
18: E-DCH Provided Bit
Rate
19: E-DCH Non-serving
Relative Grant Down
Commands
29 Inter-Frequency Handover
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
1Inter-Frequency Handover Allowed
Defines if inter-frequency HO is enabled.
0: Not allowed
1: Allowed
-
7/30/2019 All Parameter-new
21/97
2
(Inter-frequency measurement quantity)
Defines the measurement type for events 2a, 2b, 2c, 2d, 2e,
and 2f.
0: CPICH Ec/No
1: CPICH RSCP
3
(Inter-frequency measurement quantity)
Defines the measurement type for events 2a, 2b, 2c, 2d, 2e,
and 2f.
0: CPICH Ec/No
1: CPICH RSCP
4(Cell indiv idual off set) -
Used to offset measured quantity value for FDD.(-10..10)dB step 0.5dB
5
( Event 2a Threshold Used Frequency) -
Change of best frequency threshold to trigger an e2a
measurement report.
CPICH RSCP: (-115..-25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
6
-
Weighting factor to control the proportion of the primary
Cells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
(0.0..2.0) step 0.1
7(Event 2a Hysteresis) -
Allows hysteresis to be applied to the Event 2a threshold.
(0, 0.5..14.5)dB step
0.5dB
30
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
8
(Event 2a Time to Trigg er) -
Defines the period of time the measurement must exceed
the Event 2a threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
9
ven res o se requency -
Event 2b occurs when the estimated quality of the currently
used frequency is below a certain threshold and the
estimated quality of a non-used frequency is above a certain
CPICH RSCP: (-115..-
25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
10
-
Weighting factor to control the proportion of the primary
Cells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
(0.0..2.0) step 0.1
11 (Event 2b Hysteresis ) -Allows hysteresis to be applied to the Event 2b threshold. (0, 0.5..14.5)dB step0.5dB
12
(Event 2b Time to Trig ger) -
Defines the period of time the measurement must exceed
the Event 2b threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
13
(Event 2c Thresho ld Used Frequency) -
Event 2c occurs when the estimated quality of a non-used
frequency is above a certain threshold.
CPICH RSCP: (-115..-
25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
14
-
Weighting factor to control the proportion of the primary
Cells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
(0.0..2.0) step 0.1
15 (Event 2c Hysteresis) -Allows hysteresis to be applied to the Event 2c threshold. (0, 0.5..14.5)dB step0.5dB
16
(Event 2c Time to Trig ger) -
Defines the period of time the measurement must exceed
the Event 2c threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
17
(Event 2d Thresho ld Used Frequency) -
Event 2d occurs when the estimated quality of the currently
used frequency is below a certain threshold.
CPICH RSCP: (-115..-
25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
31
-
7/30/2019 All Parameter-new
22/97
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
18
-
Weighting factor to control the proportion of the primary
Cells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
(0.0..2.0) step 0.1
19(Event 2d Hysteresis ) -
Allows hysteresis to be applied to the Event 2d threshold.
(0, 0.5..14.5)dB step
0.5dB
20
(Event 2d Time to Trig ger) -
Defines the period of time the measurement must exceed
the Event 2d threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
21
(Event 2e Threshold Used Frequency) -
Event 2e occurs when the estimated quality of a non-used
frequency is below a certain threshold.
CPICH RSCP: (-115..-
25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
22
v en e s e req uen cy -
Weighting factor to control the proportion of the primary
Cells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
(0.0..2.0) step 0.1
23(Event 2e Hysteresis) -
Allows hysteresis to be applied to the Event 2e threshold.
(0, 0.5..14.5)dB step
0.5dB
24
(Event 2e Time to Trigg er) -
Defines the period of time the measurement must exceed
the Event 2e threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
25
(Event 2f Threshold Used Frequency) -
Event 2f occurs when the estimated quality of the currently
used frequency is above a certain threshold.
CPICH RSCP: (-115..-
25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
26
(Event 2f W Used Frequenc y) -
Weighting factor to control the proportion of the primary
Cells measured quantity with that of the remaining Cells
measured quantity in the active set. The results will be used
for event evaluation.
(0.0..2.0) step 0.1
27(Event 2f Hysteresis ) -
Allows hysteresis to be applied to the Event 2f threshold.
(0, 0.5..14.5)dB step
0.5dB
28
(Event 2f Time to Trigg er) -
Defines the period of time the measurement must exceed
the Event 2f threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
32
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
29( Inter- frequency RACH report ing quanti ty) -
Defines the measurement type while in Cell_Fach state.
0: CPICH Ec/No
1: CPICH RSCP
30
(Inter-frequency RACH reporting threshold)
Defines the measurement threshold for triggering a
measurement report while in Cell_Fach state.
CPICH RSCP: (-115..-
25) dBm step 1dBCPICH Ec/No: (-24..0)
dB step 1dB
31
Inter-frequency Neighbo r List Pr ior i ty L evel
This parameter allows the Cells neighbors to be ranked.
This is used when SHO conditions generate a composite NL
that may result in excessive neighbors being truncated.
0, 1, 2
-
7/30/2019 All Parameter-new
23/97
32
IRAT Neighbor List Pr ior i ty Level
This parameter allows the Cells neighbors to be ranked.
This is used when SHO conditions generate a composite NL
that may result in excessive neighbors being truncated.
0, 1, 2
32 Inter-Radio Access Technology (IRAT) Handover
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
1RAT Handover Allowed
Defines if inter-radio access technology HO is enabled.
0: Not allowed
1: Allowed
2IRAT Handover Type
Defines if compressed mode, or blind HO is used.
0: Algorithm Deciding
1: 3A Event Trigger
2: 3C Event Trigger
33
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
3Bl ind IRAT Neighbor Relat ion
Target GSM neighbor if Blind HO is enabled.
0: Neighbor;
1: Overlap;
2: Covers;
3: Contained in
4(IRAT measurement quantity)
Defines the measurement type for event 3a.
For UTRAN, 0: CPICH
Ec/No; 1: CPICH RSCP
For GSM, 0: GSM
Carrier RSSI
5(IRAT measurement quantity)
Defines the measurement type for events 3a, 3b, 3c, and 3d.
For UTRAN, 0: CPICH
Ec/No; 1: CPICH RSCP
For GSM, 0: GSM
Carrier RSSI
6(IRAT measurement quantity)
Defines the measurement type for events 3b, 3c, and 3d.0: GSM Carrier RSSI
7(Cell indiv idual off set) -
Used to offset measured quantity value for GSM.(-10..10) dB step 0.5dB
8
(Event 3a Threshold Ow n System ) -
Event 3a occurs when the estimated quality of the currently
used UTRAN frequency is below a certain threshold and the
estimated quality of the other System is above a certain
threshold.
CPICH RSCP: (-115..-
25) dBm step 1dB
CPICH Ec/No: (-24..0)
dB step 1dB
9
-
Event 3a occurs when the estimated quality of the currently
used UTRAN frequency is below a certain threshold and the
estimated quality of the other System is above a certain
(-115..0) dB step 1dB
10
(Event 3a W) -
Weighting factor to control the proportion of the primary
Cells measured quantity with that of the remaining Cells
measured quantity in the active set. The results will be usedfor event evaluation.
(0.0..2.0) step 0.1
11(Event 3a Hysteresis) -
Allows hysteresis to be applied to the Event 2a threshold.
(0, 0.5..7.5)dB step
0.5dB
12
(Event 3a Time to Trigg er) -
Defines the period of time the measurement must exceed
the Event 3a threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
34
-
7/30/2019 All Parameter-new
24/97
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
13
(Event 3b Thresho ld Other System) -
Event 3b occurs when the estimated quality of the other
System is below a certain threshold.
(-115..0) dB step 1dB
14
-
Weighting factor to control the proportion of the primary Cell
measured quantity and the remaining Cells measuredquantity in the active set, The results will be used for event
Not needed for 3b
15(Event 3b Hysteresis ) -
Allows hysteresis to be applied to the Event 2a threshold.
(0, 0.5..7.5)dB step
0.5dB
16
(Event 3b Time to Trig ger) -
Defines the period of time the measurement must exceed
the Event 3b threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
17
(Event 3c Thresho ld Other System) -
The estimated quality of the other System is above a certain
threshold.
(-115..0) dB step 1dB
18
-
Weighting factor to control the proportion of the primary
Cells measured quantity with the remaining Cells measured
quantity in the active set. The results will be used for event
Not needed for 3b
19(Event 3c Hysteresis) -
Allows hysteresis to be applied to the Event 2a threshold.
(0, 0.5..7.5)dB step
0.5dB
20
(Event 3c Time to Trig ger) -
Defines the period of time the measurement must exceed
the Event 3c threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
21(Event 3d Thresho ld Other System) -
Change of best Cell in other System.Not needed for 3d
35
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
22
(Event 3d W) -Weighting factor to control the proportion of primary Cells
measured quantity with that of the remaining Cells
measured quantity in the active set. The results will be used
for event evaluation.
Not needed for 3d
23(Event 3d Hysteresis ) -
Allows hysteresis to be applied to the Event 2a threshold
(0, 0.5..7.5)dB step
0.5dB
24
(Event 3d Time to Trig ger) -
Defines the period of time the measurement must exceed
the Event 3d threshold before a measurement report is sent.
, , , , , ,
100, 120, 160, 200, 240,
320, 640, 1280, 2560,
36 Radio Link Control (RLC)
1
AM (In-sequence d elivery) -
TRUE indicates that RLC shall preserve the order of higher
layer PDUs when these are delivered.FALSE indicates that receiving RLC entity could allow SDUs
to be delivered to the higher layer in different order than
submitted to RLC sub-layer at the transmitting side.
0: False1: True
2AM (Receiving window size)
Maximum number of outstanding (unacknowledged) RLC
PUs from the UTRANs perspective
1, 8, 16, 32,
641282565127
68102415362047
256030723584
4095Pus
-
7/30/2019 All Parameter-new
25/97
3AM (Timer_Status_Prohibit)
Minimum time in ms between STATUS reports.
(10..550 by step of 10,
550..1000 by step of
50)ms
4AM (Missing PDU Indicator)
Value true indicates that UE should send a STATUS report
for each missing PDU that is detected.
immediately send status
PDU when detected
missing)
1: True (send status
PDU when detected
37
5AM (Timer_STATUS_periodic)
Time in msecs for per iodic reports.
100200300400
500750100020
00ms
Uplink
6AM (Transmiss ion wind ow size) -
Max imum number of outs tanding (unacknowledged)
RLC PUs from the UEs perspective.
181632641
282565127681
02415362047256
0307235844095
7
AM (Timer_RST) -
reset t imer
Elapsed t ime in mi l l iseconds. It is used to tr igger the
retransmission of RESET PDU.
50100150200
250300350400
450500550600
700800900100
8AM Max_RST)
Maximum number of transmission o f Resets PDU equal
to Max _RST - 1
146812162
432
9AM (Timer_poll_prohibit)
Minimum tim e between pol ls
(10..550 by step of 10,
600..1000 by step of
50)ms
10 AM (Timer_poll) (10..550 by step of 10,
600..1000 by step of
50)ms
11AM (Poll_PDU)
Interval between p ol l ings
12481632
64128
12AM (Poll_SDU)
Interval between p ol l ings 141664
13AM (Last transmission PDU poll)
Pol l at last PDU in transmission buffer
0: False
1: True
38
14AM (Last retransmission PDU poll)
Pol l at last PDU in retransmission buffer
0: False
1: True
15AM (Poll_Window)
Pol l ing threshold
5060708085
909599%
16AM (Timer_poll_periodic)
Pol l ing per iod
100200300400
50075010002000
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/Step Size (Units)
39 Channel Reconfiguration and RRC State Management
Circuit-switched Services
1AMR5.9 @ SF256 enable
Al low/prohibi t assignment o f AMR5.9 @ SF256Not defined
-
7/30/2019 All Parameter-new
26/97
2
AMR5.9 @ SF256 cod e usage thresh old
The fract ion of SF128 spreading codes co nsum ed above
where new vo ice cal ls wi l l be assigned AMR5.9 @
SF256. Below th is threshold, vo ice cal ls wi l l be assigned
AMR12.2 variab le-rate1 @ SF128.
Not defined
Packet-switched Services
3
The state that a PS connect ion is placed into w hen
transi t ioning from IDLE. Typically this is app l icable forPS users that maintain a PDP Context, yet have gone to
Not defined, depending
on required data rate
4PS State Initial Setup
The state that a PS connect ion is placed into w hen the
users PS session is initially set up.
Not defined, depending
on required data rate
40
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
5PS Initial DL DCH Setup
The ini t ial size of the dow nl ink Transport Chann el for
Interact ive and Backgro und traff ic classes.
Downlink Maximum Rate
Threshold of PS Service
on FACH: (0..65535)
kbps step 1 kbps
6PS Initial UL DCH Setup
The ini t ial size of the upl ink Transport Channel for
Interact ive and Backgro und traff ic classes.
Uplink Maximum Rate
Threshold of PS Service
on RACH: (0..65535)
kbps step 1 kbps
7PS Initial Setup HS Capable
Defines w hether an HS-capable UE request ing PS
service is set up on HS or dedicated dow nl ink channels.
Not defined
8
The ini t ial size of the upl ink Transport Channel for
Interact ive and Backgro und traff ic classes when HS isNot defined
9
DL 384k DCH Down Switch
The threshold in the downl ink th at tr iggers a transport
channel down switch from 384k to 128k, based on RLCthroughput .
Event 4B Counter
Threshold : 1..255
10
DL 128k DCH Down Switch
The threshold in the downl ink th at tr iggers a transport
channel down switch from 128k to 64k, based on RLC
throughput .
Event 4B Counter
Threshold : 1..255
11
DL 64k DCH Down Switch
The threshold in the downl ink th at tr iggers a transport
channel down switch from 64k to 32k, based on RLC
throughput .
Event 4B Counter
Threshold : 1..255
12DCH Down Switch Timer
Time DL throug hput m ust be below DCH Down Switch
threshold to tr igger DCH Down Switch.
Not defined
Per-Cell
13
DL DCH Down Switch Qual i tyThe threshold, as reported by th e UE, which indicates
excessive BLER in the down l ink, which, in turn, tr iggers
a down switch to th e next lower transport channel .
Not defined
14
DL DCH Down Switch Power
The threshold, relat ive to the maximum DL pow er for the
radio l ink, which tr iggers a dow n switch to the next
lower transport channel .
Event A Counter
Threshold of
Consecutive DTCP
Reports: 1..255
41
-
7/30/2019 All Parameter-new
27/97
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
15
UL DCH Down Switch Qual i ty
The threshold, which indicates excessive BLER in the
upl ink, which tr iggers a down switch to the next lower
transport channel .
Not defined
16
UL DCH Down Switch Power
The threshold, relat ive to the maximum UL pow er for the
radio l ink, which tr iggers a dow n switch to the next
lower transport channel .
Not defined
17Down Switch Qual i ty Timer
Time durat ion BLER must exceed threshold to tr igg er a
qual i ty-based down sw itch.
Not defined
18
The data throug hput thresho ld, appl icable for both
upl ink and do wnl ink, which tr iggers a radio bearer
reconf igurat ion from DCH to CELL_FACH, based on
Event 4B Counter
Threshold: 1..255
19
DCH to Common Down Switch Timer
The time durat ion where the DL and UL throug hput m ust
be below the DCH to Common Dow n Switch threshold in
order to tr igger a switch to common channels.
Not defined
20
The data throug hput thresho ld, appl icable for both
upl ink and do wnl ink, which tr iggers a radio bearer
reconf igurat ion from CELL_FACH to DCH, based on
Event 4A Counter
Threshold: 1..65535
21
Common to DCH Up Switch Timer
Time durat ion either the DL or UL throughp ut mus t be
above the Commo n to DCH Up Switch threshold in order
to tr igger a switch to dedicated channels.
Not defined
22
Common Channel Inact iv i ty Timer
Time durat ion where both the DL and UL through put is
zero, in order to tr igger a state of the UE from
CELL_FACH to IDLE.
Counter Threshold of
Failing to Transfer from
CELL_DCH/CELL_FAC
H to CELL_PCH for
Transferring to Idle:
2..65535
23Enable CELL _PCH/URA_PCH States
Enables the use o f the CELL_PCH and URA_PCH.
1: Only Support
24URA_PCH State Trigger
Maximum number of Cel l Updates sent by inact ive UE in
CELL_PCH to tr igg er transi t ion to URA_PCH.
Not defined
25
_
Maximum time an inact ive UE (not transmitt ing o r
receiv ing data) remains in URA_PCH before tr igger ing
an IU Release Request mes sage to th e CN and
1..65535s
26
HS Inactiv ity Timer
Time durat ion where both the DL and UL through put iszero, for a UE uti l izing HS-DSCH, in ord er to tr ig ger a
release request message to th e CN and change the s tate
of a UE to IDLE.
Not defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
43 Admission Control
-
7/30/2019 All Parameter-new
28/97
1
DL Power Adm ission Threshold 1
Power admission thresho ld for delay intolerant RABs
(e.g., conv ersat ional and streaming) request ing
admission due to s oft /softer handover (value relat ive to
total available DL power).
(1.. 100)% step 1%
2
Power admission thresho ld for delay intolerant RABs
(e.g., conv ersat ional and streaming) request ing
admission, not du e to soft /softer handover (valuerelative to to tal available DL pow er). Typically s et
-
7/30/2019 All Parameter-new
29/97
11
down l ink hardware usage in the cell group in ord er to
reserve some resources for gu aranteed and guaranteed-
hs service class connect ions. App l icable to (non-
guaranteed, non-handov er), (guaranteed-hs, n on-
handover) and (guaranteed, non-handover) admission
(1.. 100)% step 1%
12
hardware usage in the cel l group in o rder to reserve
som e resources for guaranteed and guaranteed-hsservice class con nect ions. Appl icable to (non-
guaranteed, non-handov er), (guaranteed-hs, n on-
handover) and (guaranteed, non-handover) admission
(1.. 100)% step 1%
13
down l ink hardware usage in the cell group. Appl icable
to (non-guaranteed, hando ver), (guaranteed-hs, non -
handover) and (guaranteed, non-handover) admission
(1.. 100)% step 1%
14
Parameter that def ines the admission l imi t fo r the upl ink
hardware usage in the cel l group. Appl icable to (non-
guaranteed, handov er), (guaranteed-hs, non-handov er)
and (guaranteed, non-handover) admission requests
(1.. 100)% step 1%
15
down l ink power in order to reserve some of theresource for g uaranteed and guaranteed-hs service
class conn ect ions. Appl icable to (non-guaranteed, non-
(1.. 100)% step 1%
16
for the numb er of radio l inks in comp ressed mode in a Not defined
17
Cel l parameter that def ines the absolute admiss ion l imi t
for dow nl ink code usage in order to reserve some of the
resource for m obi l i ty of guaranteed and guaranteed-hs
service class conn ect ions. Appl icable to (guaranteed,
non-handov er), (guaranteed-hs, non-handover) and (non-
guaranteed, handover) access requests
(0~100)% step 1%
18 Maximum Transmission Power. .. .
19
Cel l parameter that def ines the absolute admiss ion l imi t
for dow nl ink pow er ut i l izat ion. Appl icable to
(guaranteed, non -handover) and (non-guaranteed,
handover) admiss ion requests
(0~100)% step 1%
20
down l ink power in order to reserve some of the
resource for m obi l i ty of guaranteed service class
conn ect ions and gu aranteed-hs service class
conn ect ions. Appl icable to (guaranteed, handover) and
(0~100)% step 1%
21Max SF8 Adm ission
Maximum n umb er of DL radio l inks al lowed in a Cell
ut i l iz ing s preading factor 8.
0..7
22Max SF16 Adm ission
Maximum n umb er of DL radio l inks al lowed in a Cell
ut i l iz ing spreading factor 16.
0..15
23Max SF32 Adm ission
Maximum n umb er of DL radio l inks al lowed in a Cell
ut i l iz ing spreading factor 32.
0..31
24Max SF64 Adm ission
Maximum n umb er of DL radio l inks al lowed in a Cell
ut i l iz ing spreading factor 64.
0..61
25Max SF128 Adm ission
Maximum n umb er of DL radio l inks al lowed in a Cell
ut i l iz ing spreading facto r 128.
0..123
-
7/30/2019 All Parameter-new
30/97
26Max SF256 Adm ission
Maximum n umb er of DL radio l inks al lowed in a Cell
ut i l iz ing spreading facto r 256.
0..200
27
Number of Compressed Mode radio l inks al lowed in a Not defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
28HSDPA Adm ission
Number of u sers in a Cell uti l izing the HS-DSCH.0..65535
29 Max Bit Rate Per QoS Group(1..65535)kbps step 1
kbps
30 Max bi t rate increase per turn Not define
31 Schedul ing weights for di f ferent traff ic classes Not defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
47 Congestion Control
1DL Power threshold for tr igger ing con gest ion (value
relative to total available DL power).(1..100)% step 1%
2DL Power threshold indicat ing con gest ion has been
resolv ed (value relative to total available DL pow er).
Typical ly set
-
7/30/2019 All Parameter-new
31/97
16The numb er of delay tolerant RABs (e.g., background
and interactiv e) that are released/reduced du ring each
cong est ion resolut ion act ion.
1..50
17The time between the detect ion of cong est ion and ini t ial
cong est ion resolut ion act ion of delay- tolerant RABs.1..255 times
18The time between each cong est ion resolut ion act ion of
delay-tolerant RABs, unt i l con gest ion is resolved1..255 times
19
The num ber of delay-intolerant RABs (e.g.,
conversat ional and streaming) that are released/reduced
dur ing each congest ion resolut ion act ion.
1..50
20The time between the detect ion of cong est ion and ini t ial
cong est ion resolut ion act ion of delay intolerant
RAB s.0/100,000/1 (ms ec)
1..255 times
21The time between each cong est ion resolut ion act ion of
delay intolerant RAB s, unt i l congest ion is resolved.1..255 times
22Time interval between per iodic cong est ion resolve
act ions on g uaranteed traff ic class connect ionNot defined
23Interval between per iodic congest ion resolve act ions on
guaranteed-hs traff ic clas con nect ions in a cel l .Not defined
24Interval between per iodic congest ion resolve act ions on
no gu aranteed traff ic class conn ect ions in a cel l .Not defined
25
ini t iated on guaranteed traff ic class con nect ions in a Not defined
26
ini t iated on guaranteed-hs traff ic class conn ect ions in a Not defined
Congestion Resolution Utilizing Inter-frequency and IRAT Handover
28
DL Power Cong est ion IF Load Shar ing Offset
The offset, relat ive to the DL Power Congest ion
Threshold 1, which ini t iates inter-frequency h andover to
col located UTRAN Cel ls.
Difference Downlink
Load Threshold in Inter-
frequency Cells -
Power:(0..100%) step
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/Step Size (Units)
29
UL Noise Congest ion IF Load Shar ing Offset
The offset, relat ive to the UL Noise Congest ion
Threshold 1, which ini t iates inter-frequency h andover to
col located UTRAN Cel ls.
Permitted Payload
Difference Uplink Load
Threshold in Inter-
frequency Cells-
Interference:(0..100%)
step 1%
30
The offset, relat ive to the DL Power Congest ion
Threshold 1, which ini t iates IRAT hando ver to col locatedNot defined
31
The offset, relat ive to the UL Noise Congest ion
Threshold 1, which ini t iates IRAT hando ver to col locatedNot defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
50 Provisioning
1 User bi t rate versus CBR -Configured according to
the traffic class and data
rate
-
7/30/2019 All Parameter-new
32/97
2Min Iub al locat ion
This would p rovide abi l i ty to al locate lesser amount of
Iub bandwidth than the associated RB SF cal l for .
Configured with the
feature of Iub
overbooking
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
51 UE Timers and Constants in Connected Mode
1(T300) -
Time between two RRC Connect ion attempts w hen not
acknowledged w ith RRC Connect ion Setup.
, , , , ,000,1200,1400,1600,18
00,2000,3000,4000,600
2(N300 ) -
Number of RRC Connect ion retransmiss ions.(0..7)
3
(T302)
Timer is stopped upon recept ion of CELL UPDATE
CONFIRM/URA UPDATE CONFIRM. Upon expiry ,
retransm it CELL UPDATE/URA UPDATE if V302 =< N302,
or else, go to IDLE mode.
(100,200,400,600,800,1
000,1200,1400,1600,18
00,2000,3000,4000,600
0,8000)ms
4(N302)
Maximum number of retransmiss ions of the CELL
UPDATE/URA UPDATE messag e.
(0..7)
5
(T304)
Timer is stopped up on recept ion of UE CAPABILITY
INFORMATION CONFIRM. Upon ex piry, retransmit UE
CAPAB ILITY INFORMATION if V304 =< N304, or else
ini t iate a Cell upd ate procedure.
(100, 200, 400, 1000,
2000)ms
6(N304)
Maximum number of retransmiss ions of the UE
CAPAB ILITY INFORMATION message.
(0..7)
7
Timer is star ted upon enter ing CELL_FACH or
URA_PCH or CELL_PCH state. Receptio n of CELL
UDPATE CONFIRM/URA UPDATE CONFIRM. Upon
expiry, transmit CELL UPDATE if T307 is n ot act ivated
and the UE detects " in service area." Otherwise, i f T307
(No
update,5,10,30,60,120,3
60,720)minutes
8
(T307) -
Timer is star ted when the t im er T305 has expired and
the UE detects "out of service area." Upon expiry,
transi t to idle mode.
(5, 10, 15, 20, 30, 40,
50)s
9(T308)
Upon expiry, transm it RRC CONNECTION RELEASE
COMPLETE if V308
-
7/30/2019 All Parameter-new
33/97
12
Timer is star ted upo n transmiss ion of PUSCH
CAPACITY REQUEST. Upon exp iry, transm it PUSCH
CAPACITY REQUEST if V310 =< N310, or else pro cedu re
Not used
13(N310)
Maximum number of retransmission of the PUSCH
CAPACITY REQUEST mess age.
Not used
14
Timer is star ted upo n recept ion of PHYSICAL SHAREDCHANNEL A LLOCATION message with the CHOICE
"PUSCH al locat ion" set to " PUSCH al locat ion pend ing."
Upon ex piry, UE may initiate a PUSCH capacity req uest
Not used
15
(T312)
Timer is star ted when the UE star ts to establ ish
dedicated CH. Upon expiry, the cr i ter ion for p hysical
channel establ ishment fai lure is ful f i l led.
(1..15)s
16(N312)
Maximum number of " in sy nc(s)" is received from L1.
, , , , , , ,
200, 400, 600, 800,
17
(T313)
Timer is star ted when the UE detects co nsecut ive N313
"out of sync" indicat ions f rom L1. Upon expi ry , the
cr i ter ion for Radio L ink fai lure is ful f i l led.
(0..15)s
18(N313)
Maximum number of success ive "out of sync(s)" is
received from L1.
(1, 2, 4, 10, 20, 50, 100,
200)
19
(T314)
Timer is star ted wh en the cr i ter ia for radio l ink fai lures
are fulfi l led. The timer is started if radio b earer(s) that
are associated with T314 exist or i f only RRC connect ion
exists. Upon expiry , the UE shall release all radio
bearers that have th e re-establ ishment t imer set to T314.
(0, 2, 4, 6, 8, 12, 16,
20)s
20
(T315)
Timer is star ted wh en the cr i ter ia for radio l ink fai lure is
fulfi l led. The timer is started if rad io bearer(s) that are
associated with T315 exist or i f only RRC con nect ion
exists. Upon expiry , the UE shall release all radio
bearers that have th e re-establ ishment t imer set to T315.
(0,10, 30, 60, 180, 600,
1200, 1800)s
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
21(N315)
Maximum number of successive " in sync(s)" is received
from L1 when T313 is act ivated.
(1, 2, 4, 10, 20, 50, 100,
200, 400, 600, 800,
1000)
22
Timer is star ted wh en the UE detects " out of s ervice
area" in URA_PCH or CELL_PCH state. Upon expiry,
init iate Cell upd ate proced ure if in service area is
detected . Otherw ise start timer T317, transit to
CELL_FACH state, and ini t iate Cel l update pro cedure
" "
(0, 10, 20, 30, 40, 50,Infinity )s
23
(T317)
Timer is star ted when the T316 expires or when in
CELL_FACH state, the UE detects "o ut o f service area."
This t imer never expires.
(0,10, 30, 60, 180, 600,
1200, 1800)s
-
7/30/2019 All Parameter-new
34/97
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
54 High Speed Downlink Packet Access
1 Defines if HSDPA is enab led in a Cell.
0: Not Support HSUPA
and HSDPA;
1: Support HSDPA and
DCH;2: Support HSDPA only;
3: Support HSUPA ,
HSDPA and DCH;
4: Support HSUPA and
HSDPA
2
HSDPA Max Available Power
Defines the maxim um DL power that can b e al located to
al l channels in a Cel l when HSDPA is u sed, including the
HS-DSCH, the HS-SCCH, all common ch annels, and all
dedicated channels.
(1..100)% step 1%
3
The maximum power fo r the HS-SCCH, relat ive to th e Not defined
4
Interval of per iodic report ing w hen tr iggered by e1d (0..65535)s step 1s
5HSDPA (Event 1d Hysteresis)
Add ed amount to A ct ive Cel l replacement threshold to
ensure that the thresho ld has def ini tely been exceeded.
(0..7.5)dB step 0.5dB
6
Indicates the per iod of t ime dur ing w hich new Cel l has
to be better than threshold before sending a(0..65535)s step 1
7 Number of HS-SCCH 1..32
8 Scheduler Type
1: C/I Schedule
2: Priority Schedule
3: Fair ThroughputSchedule Based on
Priority
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
9 Schedul ing weights for di f ferent traff ic classes Not defined
10 Weight for di f ferent compo nents Not defined
11HSDSCHQoSclasses
Defines w hich traff ic handl ing c lasses/pr ior i t ies are
al lowed to get HSDPA service
Not defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
56 Enhanced Uplink ( High Speed Uplink Packet Access)
1Maximum E-DCH Act ive Set Size
This would def ine the maximum number of cel ls allowed
in the E-DCH Active set.
1..4
-
7/30/2019 All Parameter-new
35/97
2 E-DCH TTI0: 2ms
1: 10ms
3E-DPCCH Power Off set
This parameter controls the relat ive power between the
E-DPCCH and R99 DPCCH.
0..8
4
E-AGCH/E-HICH/E-RGCH Power Offset
This is the relative power of fset betw een the P-CPICH
and the E-AGCH, betw een th e P-CPICH and E-HICH, and
betw een the P-CPICH and E-RGCH. It is u sed b etween
RNC and Node B . Configurable parameters enable
rel iable detect ion of these channels throu ghou t the cel l .
Power offset relative to
DL DPCH pilot domain: (-
32 .. +31.75)dB step0.25 dB
5Maximum number of E-DPDCHs
This is the maximum number of E-DPDCHs that the
UTRAN al lows for a given UE. For maximum throug hput,
Not defined
6
E-TFCI Table Ind ex
This parameter enables th e expon ential ly-distr ibuted
transport block sizes or f ixed RLC PDU size-related
transport block sizes.
0..1
7
Happy bi t delay condi t ion
The UE uti l izes this p arameter to determine wh ether to
send Schedul ing Inform ation or not. It wi l l help inf luence
average latency .
(2ms, 10ms,20ms,50ms,
100ms, 200ms, 500ms,
1000ms)
8
Number of E-RGCHs
This is the maximum number of E-RGCHs allowed in a
cel l . This wi l l inf luence maximum number of
supp ortable/Act ive HSUPA users.
1..10
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
9
Number o f E-AGCHs
This is the maximum n umb er of E-AGCHs al lowed in a
cel l . This wi l l inf luence maximum number of
supp ortable/Act ive HSUPA users.
1..10
10
(Reference E-TFCI Set and E-TFCIs Power Off sets
The UE uses this table to determine the sup portable
data rate (=E-TFCI) in the up link. This p arameter
effect ively contro ls the error rate and i t is very imp ortant
to have f lexibi l i ty to change.
e o e erence -
TFCIs (2ms E-TTI, E-
TFCI Table0): 0..127
Set of Reference E-
TFCIs (2ms E-TTI, E-
TFCI Table1): 0..125
Set of Reference E-
TFCIs (10ms E-TTI, E-
TFCI Table0): 0..127
Set of Reference E-
TFCIs (10ms E-TTI, E-
TFCI Table1): 0..120
Power Offset of
Reference E-TFCIs:0..29
11
Init ial Serving Gr ant
This is the power offset between the E-DPDCH and the
DPCCH that the UE can star t usin g before the UTRAN
star ts sending absolute and relat ive grants. It wi l l help
reduce initial startup delay.
0..8
-
7/30/2019 All Parameter-new
36/97
12Support for scheduled and non-scheduled data
transmission
0: Scheduled
Transmission Grant
1: Non-scheduled
Transmission Grant
13 Support for f ixed and dy namic RV parameters0: RV0
1: RV Table
14 Support fo r MAC-d f low speci f ic HARQ prof i les Not defined
15 maxEDchRate(1..655535)kbps step 1
kbps
16
Maximum d ynamic delay (buffer bui ld-ups ov er Iub,
including the nod e's ET boards) that the E-DCH data
frames can have without being detected as a dynamic
delay Iub con gest ion.
Not defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
17 IubEdchId Not defined
18 userLabel Not defined
19 t ransmissionTargetError Not defined
20 ulInitSirTargetEdch(-8.2..17.3) dB step 0.1
dB
21 eDchCapabil i ty
0: Not Support HSUPA
and HSDPA;
1: Support HSDPA and
DCH;
2: Support HSDPA only;3: Support HSUPA ,
HSDPA and DCH;
4: Support HSUPA and
HSDPA
22 eulLockedOptimalNoiseFloorEst imate Not defined
23 eulMaxOwnUuLoad (0..62) dB step 0.1 dB
24 eulMaxRotCoverage Not defined
25 eulMinMarginCoverage Not defined
26 eulOptimalNoiseFloorLock Not defined
27 eulOptimalNoiseFloorLock.eulNoiseFloorLock Not defined
28eu p ma o se oor oc .eu p ma o se oor s ma
Not defined
29 eulSl idingWindowTime..
30 eulThermalLevelPrior Not defined
31 harqTransmUlTti10Max Not defined
32 eulMaxShoRate(1..655535)kbps step 1
kbps
33 eulNoReschUsers Not defined
34 eulTargetRate(1..65535)kbps step 1
kbps
35 eulMaxNoSchEDch 0..65535
36 eulNoERgchGroups Not defined
-
7/30/2019 All Parameter-new
37/97
37 maxEAgchPowerDl Not defined
38 maxUserEHichERgchPowerDl Not defined
Sr. No. Parameter Name Description
Minimum Value/
Maximum Value/
Step Size (Units)
39
eulNonServingCel lUsersAdm
Adm ission threshold for the num ber of E-DCH usershaving th is Cel l as serving Cel l .
0..65535
40eulServingCel lUsersAdm
Adm ission threshold for the num ber of E-DCH users
having th is Cel l as serving Cel l .
0..65535
41
even nc se
Offset add ed to the cu rrent E-DCH/HS-DSCH Serving
Cel l measurements received in the event 1a and 1c
Measurement Reports, in order to evaluate if an
indiv idual non -EUL Cel l has higher qual i ty than th e
curr ent E-DCH/HS-DSCH Serving Cell. If th e no n-EUL
Cell is "better" , event 1d-RNC is tr iggered, and that Cell
wi l l ei ther be added to the act ive set, or wi l l replace a
Not defined
42Number of co nsecut ive t imes that an indiv idual non-EUL
Cel l must have a higher q ual i ty level than the current E-
DCH/HS-DSCH Serving Cell, in order to tr igg er event 1d-
1..7
-
7/30/2019 All Parameter-new
38/97
Default Granularity/ Scope
2 Per-Cell
-15dB Per-Cell
-111dBm Per-Cell
24dBm Per-Cell
Default Granularity/ Scope
14dB Per-Cell
2dB Per-Cell
2dB Per-Cell
2dB Per-Cell
2dB Per-Cell
2dB Per-Cell
2dB Per-Cell
0dB Per-Cell
0dB Per-Cell
1s Per-Cell
-
7/30/2019 All Parameter-new
39/97
Default Granularity/ Scope
2s Per-Cell
2s Per-Cell
0.5 Per-Cell
10dB Per-Cell
2 Per-Cell
2dB Per-Cell
2 Per-Cell
always Per-Cell
-12dB Per-Cell
Default Granularity/ Scope
always
Not Used Group of Cells
9dB Per-Cell
Not Used Per-Cell
-
7/30/2019 All Parameter-new
40/97
8 Group of Cells
Not Used Group of Cells
9dB Group of Cells
6dB Group of Cells
10s Group of Cells
9dB Group of Cells
Default Granularity/ Scope
12dB Group of Cells
0 Group of Cells
-92(Serving cell)/-90neighboring cell Group of Cells
Not used Group of Cells
Default Granularity/ Scope
N Per-Cell
N Per-Cell
N Per-Cell
N Per-Cell
Inter-frequency Switch On/Off/Off Per-Cell
-
7/30/2019 All Parameter-new
41/97
N Per-Cell
45%/45%/45% Per-Cell
Default Granularity/ Scope
-7dB Per-Cell
0 Per-Cell
-21dB Per-Cell
1dB Per-Cell
2 Per-Cell
40 Per-Cell
6 Per-Cell
3 Per-Cell
40 Per-Cell
1 Per-Cell
0.9 Per-Cell
10s Per-Cell
[11,11] Per-Cell
[15,15] Per-Cell
Default Granularity/ Scope
-
7/30/2019 All Parameter-new
42/97
Not Barred Per-Cell
1 Per-Cell
6 Per-Cell
6 Per-Cell
6 Per-Cell
-5dB Per-Cell
72 Per-Cell
6 Per-Cell
Default Granularity/ Scope
Not Used per-RB AND per- Cell
33dBm External Utran Cell
Not Used RNC
MinDlDpchPwr per-RB AND per-Cell
MaxDlDpchPwr per-RB AND per-Cell
-3dB Per-Cell
-4dB Per-Cell
-3dB Per-Cell
-
7/30/2019 All Parameter-new
43/97
-1dB for FACH,-3dB for PCH Per-Cell
-7dB Per-Cell
-5dB Per-Cell
Default Granularity/ Scope
Conversational DL 3.4k Signaling(AM) 3dB
Conversational DL WAMR6.60k~23.85k 3dB
Conversational DL 64K(PS Conversational
Video) 3dB
Conversational UL NAMR4.75k~12.2k3dB
Streaming PS64k3dB
Streaming PS384k0dB
Streaming PS128k0dB
Interactive PS64k3dBInteractive PS384k0dB
Interactive PS128k0dB
Background PS64k3dB
Background PS384k0dB
Background PS128k0dB
Streaming CS64k3dB
Interactive DL PS 1.2Mbps0dB
per-RB combination
-
7/30/2019 All Parameter-new
44/97
Conversational DL WAMR6.60k~23.85k 3dB
Conversational DL 64K(PS Conversational
Video) 3dB
Conversational DL
NAMR4.75k~12.2k3dB;Streaming PS64k3dB
Streaming PS384k0dB
Streaming PS128k2dB
Interactive PS64k3dBInteractive PS384k0dB
Interactive PS128k2dB
Background PS64k3dB
Background PS384k0dB
Background PS128k2dB
Streaming CS64k3dB
Interactive DL PS 1.2Mbps0dB
Interactive DL PS 3.65Mbps0dB
Interactive DL PS 7.2Mbps0dB
Interactive DL PS 10.1Mbps0dB
Interactive DL PS 14.0Mbps0dB
Background DL PS 1.2Mbps0dBBackground DL PS 3.65Mbps0dB
Background DL PS 7.2Mbps0dB
Background DL PS 10.1Mbps0dB
Background DL PS 14.0Mbps0dB
Streaming DL PS 1.2Mbps0dB
Streaming DL PS 3.65Mbps0dB
Streaming DL PS 7.2Mbps0dB
Streaming DL PS 10.1Mbps0dB
Streaming DL PS 14.0Mbps0dB
per-RB combination
-
7/30/2019 All Parameter-new
45/97
Conversational DL 3.4k Signaling(AM) 3dB
Conversational DL WAMR6.60k~23.85k 3dB
Conversational DL 64K(PS Conversational Video)
3dB
Conversational DL NAMR4.75k~12.2k3dB
Streaming PS64k3dB
Streaming PS384k3dB
Streaming PS128k3dB
Interactive PS64k3dB
Interactive PS384k3dB
Interactive PS128k3dB
Background PS64k3dB
Background PS384k3dB
Background PS128k3dB
Streaming CS64k3dB
Interactive DL PS 1.2Mbps3dB
Interactive DL PS 3.65Mbps3dB
Interactive DL PS 7.2Mbps3dB
Interactive DL PS 10.1Mbps3dB
Interactive DL PS 14.0Mbps3dB
Background DL PS 1.2Mbps3dBBackground DL PS 3.65Mbps3dB
Background DL PS 7.2Mbps3dB
Background DL PS 10.1Mbps3dB
Background DL PS 14.0Mbps3dB
Streaming DL PS 1.2Mbps3dB
Streaming DL PS 3.65Mbps3dB
Streaming DL PS 7.2Mbps3dB
Streaming DL PS 10.1Mbps3dB
Streaming DL PS 14.0Mbps3dB
per-RB combination
Not Usedper-RB combination AND
per-Cell
Not Used
per-RB combination AND
per-Cell
Not Usedper-RB combination AND
per-Cell
3 per-transport channel type
-
7/30/2019 All Parameter-new
46/97
Conversational uL 3.4k Signaling(AM)8.0dB
Conversational UL AMR6.60k~23.85k6.0dB
Conversational UL 64K(PS Conversational Video)
8.0dB
Conversational UL NAMR4.75k~12.2k6.0dB
Streaming PS64k8dB
Streaming PS384k17.3dB
Streaming PS128k17.3dB
Interactive PS64k8dB
Interactive PS384k17.3dB
Interactive PS128k17.3dB
Background PS64k8dB
Background PS384k17.3dB
Background PS128k17.3dB
Streaming CS64k8.0dB
Interactive UL PS 1024kbps15dB
Interactive UL PS 2.048Mbps15dB
Interactive UL PS 3. 072Mbps15dB
Interactive UL PS 4.096Mbps15dB
Interactive UL PS 5.76Mbps15dB
Background UL PS 1024kbps15dB
Background UL PS 2.048Mbps15dB
Background UL PS 3. 072Mbps15dB
Background UL PS 4.096Mbps15dB
Background UL PS 5.76Mbps15dB
Streaming UL PS 1024kbps15dB
Streaming UL PS 2.048Mbps15dB
Streaming UL PS 3. 072Mbps15dB
Streaming UL PS 4.096Mbps15dB
Streaming UL PS 5.76Mbps15dB
per-RB combination AND
per-Cell
-
7/30/2019 All Parameter-new
47/97
onversa ona u . gna ng .
Conversational UL AMR6.60k~23.85k0.5dB
Conversational UL 64K(PS Conversational
Video) 2.0dB
Conversational UL NAMR4.75k~12.2k0.5dB
Streaming PS64k2.0dB
Streaming PS384k6.0dB
Streaming PS128k6.0dB
Interactive PS64k2.0dBInteractive PS384k6.0dB
Interactive PS128k6.0dB
Background PS64k2.0dB
Background PS384k6.0dB
Background PS128k6.0dB
Streaming CS64k2.0dB
Interactive UL PS 1024kbps4.0dB
Interactive UL PS 2.048Mbps4.0dB
Interactive UL PS 3. 072Mbps4.0dB
Interactive UL PS 4.096Mbps4.0dB
Interactive UL PS 5.76Mbps4.0dB
Background UL PS 1024kbps4.0dBBackground UL PS 2.048Mbps4.0dB
Background UL PS 3. 072Mbps4.0dB
Background UL PS 4.096Mbps4.0dB
Background UL PS 5.76Mbps4.0dB
Streaming UL PS 1024kbps4.0dB
Streaming UL PS 2.048Mbps4.0dB
Streaming UL PS 3. 072Mbps4.0dB
Streaming UL PS 4.096Mbps4.0dB
Streaming UL PS 5.76Mbps4.0dB
per-RB combination AND
per-Cell
-
7/30/2019 All Parameter-new
48/97
. .
Conversational UL AMR6.60k~23.85k2.0dB
Conversational UL 64K(PS Conversational Video)
Conversational UL NAMR4.75k~12.2k2.0dB
Streaming PS64k4dB
Streaming PS384k12.0dB
Streaming PS128k11.0dB
Interactive PS64k4dB
Interactive PS384k12.0dBInteractive PS128k11.0dB
Background PS64k4dB
Background PS384k12.0dB
Background PS128k11.0dB
Streaming CS64k4.0dB
Interactive UL PS 1024kbps6.0dB
Interactive UL PS 2.048Mbps6.0dB
Interactive UL PS 3. 072Mbps6.0dB
Interactive UL PS 4.096Mbps6.0dB
Interactive UL PS 5.76Mbps6.0dB
Background UL PS 1024kbps6.0dB
Background UL PS 2.048Mbps6.0dB
Background UL PS 3. 072Mbps6.0dB
Background UL PS 4.096Mbps6.0dB
Background UL PS 5.76Mbps6.0dB
Streaming UL PS 1024kbps6.0dB
Streaming UL PS 2.048Mbps6.0dB
Streaming UL PS 3. 072Mbps6.0dB
Streaming UL PS 4.096Mbps6.0dB
Streaming UL PS 5.76Mbps6.0dB
per-RB combination AND
per-Cell
Not Used per-Cell
24dBm
per-RB combination AND
per-Cell
[11,11]per-RB combination AND
per-Cell
[15,15]per-RB combination AND
per-Cell
3 per-transport channel type
Default Granularity/ Scope
3per-RB combination AND
per-Cell
-
7/30/2019 All Parameter-new
49/97
1 per-Cell
0per-RB combination AND
per-Cell
3dBper-RB combination AND
per-Cell
320msper-RB combination AND
per-Cell
0per-RB combination AND
per-Cell
Default Granularity/ Scope
0dBper-RB combination AND
per-Cell
2000msper-RB combination AND
per-Cell
2per-RB combination AND
per-Cell
5dBper-RB combination AND
per-Cell
1280msper-RB combination AND
per-Cell
0
per-RB combination AND
per-Cell
0dBper-RB combination AND
per-Cell
2000msper-RB combination AND
per-Cell
2per-RB combination AND
per-Cell
-
7/30/2019 All Parameter-new
50/97
320msper-RB combination AND
per-Cell
2000msper-RB combination AND
per-Cell
Default Granularity/ Scope
2per-RB combination AND
per-Cell
3dBper-RB combination AND
per-Cell
4dBper-RB combination AND
per-Cell
320ms per-RB combination ANDper-Cell
500msper-RB combination AND
per-Cell
4dBper-RB combination AND
per-Cell
320msper-RB combination AND
per-Cell
-24dBper-RB combination AND
per-Cell
200msper-RB combination AND
per-Cell
2dBper-RB combination AND
per-Cell
Default Granularity/ Scope
-24dBper-RB combination AND
per-Cell
200msper-RB combination AND
per-Cell
-
7/30/2019 All Parameter-new
51/97
2dBper-RB combination AND
per-Cell
0 Per Cell
0dBPer Cell and Per Neighbor
FDD Cell
0 Per Cell
0 Per Cell
Default Granularity/ Scope
1
0 Per-RNC
1 Per-RNC
1 Per-RNC
0 Per-RNC
Default Granularity/ Scope
0 Per-RNC
1 Per-RNC
1 Per-RNC
0 Per-RNC
-
7/30/2019 All Parameter-new
52/97
0 Per-RNC
1 Per-RNC
1 Per-RNC
0 Per-RNC
Default Granularity/ Scope
1 Per-RNC
500ms Per-RNC
No need Per-RNC
No need Per-RNC
Default Granularity/ Scope
-
7/30/2019 All Parameter-new
53/97
Configuration Number for DCH): 1024 bytes
1 (UE Traffic Volume Event Measurement
Configuration Number for DCH): 512bytes
2 (UP Traffic Volume Measurement Configuration
Number for DCH): 512 bytes
3 (UE Traffic Volume Period Measurement
Configuration Number for RACH): 1024 bytes
4 (UE Traffic Volume Event MeasurementConfiguration Number for RACH): 128bytes
5 (UP Traffic Volume Measurement Configuration
Number for FACH): 128bytes
6 (UP Traffic Volume Measurement Configuration
Number for Streaming Class on HS-DSCH): 12K,bytes
7 (UP Traffic Volume Measurement Configuration
Number for Interactive and Background Class on HS-
DSCH): 6Kbytes
8 (UE Traffic Volume Period Measurement
Configuration Number for E-DCH): 1024bytes
9 (UP Throughput Event Measurement Configuration
Number for E-DCH): 1024 bytes
Transport Channel
Configuration Number for DCH): 640ms
1 (UE Traffic Volume Event Measurement
Configuration Number for DCH): 80ms
2 (UP Traffic Volume Measurement Configuration
Number for DCH): 80ms
3 (UE Traffic Volume Period Measurement
Configuration Number for RACH): 320ms
4 (UE Traffic Volume Event Measurement
Configuration Number for RACH): 80ms
5 (UP Traffic Volume Measurement Configuration
Number for FACH): 80ms
6 (UP Traffic Volume Measurement Configuration
Number for Streaming ;Class on HS-DSCH): 80ms7 (UP Traffic Volume Measurement Configuration
Number for Interactive and Background Class on HS-
DSCH): 80ms
8 (UE Traffic Volume Period Measurement
Configuration Number for E-DCH): 640ms
9 (UP Throughput Event Measurement Configuration