alpha coated

21
AMERISTARFENCE.COM | 888-333-3422 Power Utility Chemicals of interest Industrial Storage Counter Terrorism Data Storage Sally Ports Threat Standoff Blast Mitigation Caging j j j j j j j j PRIMARY APPLICATIONS HIGH SECURITY GROUNDABLE PERIMETER ENCLOSURE GRID The cutting-edge security fencing expands to accommodate your level of required security. Multiple mesh options allow you to select the degree of delay and site visibility. Strength and security combine with a stylish design to protect your first-line of defense. ALPHA ® COATED ENGINEERED SOLUTIONS Designed as a layered solution, Matrix systems exceed expectations and meet strict security standards. MEETS ASCE 7-10 EXPOSURE C WIND LOAD CONFORMS TO IEEE GROUNDING STANDARDS MEETS ASTM F2781 FORCED ENTRY STANDARD EXPANDABLE TO MEET ASTM F2656 CRASH BARRIER STANDARD

Upload: others

Post on 22-Nov-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ALPHA COATED

AMERISTARFENCE.COM | 888-333-3422

Power Utility Chemicals of interest Industrial Storage Counter Terrorism Data Storage Sally Ports Threat Standoff Blast Mitigation Caging

j

j

j

j

j

j

j

j

PRIM

ARY

APPL

ICAT

IONS

HIGH SECURITY GROUNDABLE PERIMETER ENCLOSURE GRIDThe cutting-edge security fencing expands to accommodate your level of required security. Multiple mesh options allow you to select the degree of delay and site visibility. Strength and security combine with a stylish design to protect your first-line of defense.

ALPHA®COATED

ENGINEERED SOLUTIONS

Designed as a layered solution, Matrix systems exceed expectations and meet strict security standards.

MEETS ASCE 7-10EXPOSURE C WIND LOAD

CONFORMS TO IEEEGROUNDING STANDARDS

MEETS ASTM F2781FORCED ENTRY STANDARD

EXPANDABLE TO MEET ASTM F2656 CRASH BARRIER STANDARD

Page 2: ALPHA COATED

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM

HIGH SECURITY GROUNDABLE PERIMETER ENCLOSURE GRID

2" x 2" RAILS | 3" x 6" or 6" x 6" POSTS

FABRICATION & DESIGN

Matrix Alpha Coated security fence is a groundable perimeter enclosure grid designed to expand to the level of site security required. Its framework structure allows the user to define the level of security needed by choosing a suitable mesh option that details the degree of delay and site visibility. The Matrix design is a result of multiple power utility companies seeking a design that could comply with CIP-014 physical security standards.

PERMACOAT ™PROTECTIVE FINISH

Ameristar’s production facilities use a state-of-the-art polyester powder coating system that provides a durable and scratch resistant finish. Matrix Alpha Coated is protected with Ameristar’s PermaCoat multi-layer coating process. The combination of these layers delivers a system that increases weathering resistance and product durability. The Ameristar coating system results in finished surfaces with unmatched performance.

10 YEAR LIMITED WARRANTY

Matrix Alpha Coated is coated using Ameristar’s PermaCoat process, this dual-coat finish yields the best results for durability and weathering in the fence industry. Ameristar has over 25 years of experience and research in coating fence products allowing Impasse to support a 10 year warranty.

DOMESTIC MANUFACTURING

Ameristar is committed to providing products that are manufactured in the USA. We have made significant investments in technology, process improvement, and employee training in an effort to secure American jobs and combat inferior import products.

INFILL OPTIONS

X-SPAN ULTRAX-SPAN MOD WELDED WIRE 8GA.

ALPHA®COATED

Page 3: ALPHA COATED

3" x 6" & 6" x 6" POSTS

2" X 2" RAILS

VARIOUS INFILL OPTIONS

17 HEIGHTS, 4 DIFFERENT CONFIGURATIONS (see following page)

A

B

C

D

MATRIX ALPHA COATED® | MULTIPLE SECURITY MESH OPTIONS

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.51

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

1.00

VARY BASED UPON

SITE CONDITIONS

AVAILABLE

NOTES:1. VARIOUS MESH INFILL OPTIONS AVAILABLE. SEE SPECIFICATION FOR DETAILS.2. 3" x 6" x .083 wall POST SHOWN IN ELEVATION. POST OPTIONS VARY BASED UPON FENCE HEIGHT, SITE CONDITIONS AND WIND LOADING REQUIREMENTS.3. OPTIONAL SPIKE DETERRENT STRIPS SHOWN IN ELEVATION. 3-WIRE BARB ARMS FOR INSTALLATION OF BARB WIRE ALSO AVAILABLE.4. INFILL TO RAIL ATTACHMENT METHODS VARY BASED ON SPECIFICATION REQUIREMENTS.5. * ON CENTER POST SPACING SHALL BE BASED UPON WIND LOAD AND SITE CONDITIONS. POST SPACING NOT TO EXCEED 12' ON CENTER.6. OPTIONAL ANIMAL MITIGATION SHIELD AVAILABLE FOR DETERRING INTRUSION OF NUISANCE ANIMALS.

UP TO 15'

Page 4: ALPHA COATED

17 HEIGHTS, 4 DIFFERENT RAIL CONFIGURATIONS

7 Ft. thru 10 Ft. = 3 rails, 1 infill sheet

10.5 Ft. thru 12 Ft. = 4 rails, 1 infill sheet

10.5'11.0' 11.5' 12.0'

12.5 Ft. thru 14.5 Ft. = 4 rails, 2 infill sheets

12.5' 13.0' 13.5' 14.0' 14.5'

7.0' 7.5' 8.0' 8.5' 9.0' 9.5' 10.0'

15 Ft. = 5 rails, 2 infill sheets

15.0'

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.52

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

Page 5: ALPHA COATED

Item

Num

ber

MA

13U

X600

53

MA

XEJ

MA

13U

X600

84

MA

13U

X600

90

MA

13U

X600

96

MA

13U

X601

02

MA

13U

X601

08

MA

13U

X601

14

MA

13U

X601

20

MA

13U

X601

26

MA

13U

X601

32

MA

13U

X601

38

MA

13U

X601

44

7 61

7.5 65

8 69

8.5 74

9 78

9.5 82

10 87

10.5 91

11 95

11.5 99

12 104

12.5 38 3 69

13 38 3 74

13.5 38 3 78

14 38 3 82

14.5 38 3 87

15 38 3 91

Pallet Qty. 91 N/A 57 54 50 48 43 43 40 38 37 36 33

Fenc

e H

eigh

t

EXAMPLE:

MATRIX ALPHA COATED® | INFILLS

Matrix Alpha Coated mesh/wire is hung in a curtain wall manner. System heights 7' thru 12' are accomplished with a single sheet. For handling purposes, fence heights 12.5' through 15' are accomplished by combining a standard 4.5' top sheet with the appropriate bottom sheet to make up total finished fence height and an Expansion Joint to connect the two panels after hanging.

X-SPAN ULTRA

.5 x #13 std. option

Expanded metal steel mesh provides modest delay to cut-through threats and moderate visual screening.

Lbs./Ea.XXX

SINGLE INFILL SHEET

TOP INFILL SHEET

EXTENSION JOINT

BOTTOM INFILL SHEET

7' THRU 12' HEIGHTS ACCOMPLISHED WITH SINGLE

INFILL SHEET(10' HEIGHT SHOWN)

12.5' THRU 15' HEIGHTS ACCOMPLISHED WITH 2 INFILLSHEETS & EXPANSION JOINT

(12.5' HEIGHT SHOWN)

STEP 1: Choose height of fence

STEP 2: Slide over to Blue indicator

STEP 3: Go up to Item Number

9

MA

13U

X601

08

43 Indicatespallet quantity

78

Indicatesweight

Indicates part number(s) required for one section of fence at designated height.

NOTE: ALL MATRIX INFILL'S ARE 5' WIDTH ▶ ▶

17 HEIGHTS, 4 DIFFERENT RAIL CONFIGURATIONS

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.53

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

Page 6: ALPHA COATED

MATRIX ALPHA COATED® | INFILLS

Item

Num

ber

MA

13R

X600

53

MA

XEJ

MA

13R

X600

84

MA

13R

X600

90

MA

13R

X600

96

MA

13R

X601

02

MA

13R

X601

08

MA

13R

X601

14

MA

13R

X601

20

MA

13R

X601

26

MA

13R

X601

32

MA

13R

X601

38

MA

13R

X601

44

7 109

7.5 116

8 124

8.5 132

9 140

9.5 147

10 155

10.5 163

11 171

11.5 178

12 186

12.5 68 3 124

13 68 3 132

13.5 68 3 140

14 68 3 147

14.5 68 3 155

15 68 3 163

Fenc

e H

eigh

t

Pallet Qty. 51 N/A 33 31 28 27 26 24 22 21 21 20 18

Lbs./Ea.XXX

NOTE: ALL MATRIX INFILL'S ARE 5' WIDTH

STEP 1: Choose height of fence

STEP 2: Slide over to Blue indicator

STEP 3: Go up to Item Number

EXAMPLE:

9

140

MA

13R

X601

08

26

Indicatesweight

Indicatespallet quantity

Indicates part number(s) required for one section of fence at designated height.

▶ ▶

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.54

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

X-SPAN MODIFIED

.5" x #13R (.188 strand) std. option

Modified expanded metal steel mesh provides superior delay to cut-through threats as well as ample visual screening.

Page 7: ALPHA COATED

MATRIX ALPHA COATED® | INFILLS

Item

Num

ber

MA

AC

8X60

053

MA

AC

8X53

060

MA

XEJ

MA

AC

8X60

084

MA

AC

8X60

090

MA

AC

8X60

096

MA

AC

8X60

102

MA

AC

8X60

108

MA

AC

8X60

114

MA

AC

8X60

120

MA

AC

8X60

126

MA

AC

8X60

132

MA

AC

8X60

138

MA

AC

8X60

144

7 70

7.5 81

8 86

8.5 91

9 97

9.5 102

10 108

10.5 *113

11 *118

11.5 *124

12 *129

12.5 48 3 3 86

13 48 3 91

13.5 48 3 97

14 48 3 102

14.5 48 3 108

15 *48 3 *113

Pallet Qty 72 72 N/A 50 44 40 38 36 34 32 31 29 28 27

Fenc

e H

eigh

t

*Orientation of wire rotated 90° due to manufacturing requirements

Lbs./Ea.XXX

NOTE: ALL MATRIX INFILL'S ARE 5' WIDTH

STEP 1:Choose height of fence

STEP 2:Slide over to Blue indicator

STEP 3:Go up to Item Number

EXAMPLE:

12.5

MA

AC

8X60

096

40

Indicates part number(s) required for one section of fence at designated height.

Indicatespallet quantity

MA

XEJ

N/A

MA

AC

8X60

053

72

+

48 Indicatesweight

3 86+ +

+

▶▶

▶ ▶

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.55

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

WIREWORKS

.5" x 3" x 8GA. option

Welded Wire steel mesh provides ample delay to cut-through threats and modest visual screening.

Page 8: ALPHA COATED

Each track has 2 round holes at the top and2 at the bottom for grounding fasteners.

HARDWARE INFORMATION FOR T-TRACKS

All T-Tracks supplied with 4 "H" fasteners for grounding purposes regardlessof Slot Hardware option.

STEP 1: Choose height of fence

STEP 2: Slide over to Blue indicator

STEP 3: Go up to Item Number

EXAMPLE:

11.5

9.1

MA

XTC

-11.

5

9.1

Indicatesweight

Indicatespallet quantity

Indicates part number(s) required for one section of fence at designated height.

NOTE: T-Track / Infill Covers are used to join infill sheets. Therefore, the quantities required should match the infill sheet quantity.

NOTE: HARDWARE NOT INCLUDED, SEE FASTENER SECTION

Lbs./Ea.XX

Item

Num

ber

MA

XTC

-4.5

MA

XTC

-7

MA

XTC

-7.5

MA

XTC

-8

MA

XTC

-8.5

MA

XTC

-9

MA

XTC

-9.5

MA

XTC

-10

MA

XTC

-10.

5

MA

XTC

-11

MA

XTC

-11.

5

MA

XTC

-12

7 5.6

7.5 6.0

8 6.4

8.5 6.8

9 7.1

9.5 7.5

10 7.9

10.5 8.3

11 8.7

11.5 9.1

12 9.5

12.5 3.6 3 16

13 3.6 16

13.5 3.6 20

14 3.6 20

14.5 3.6 20

15 3.6 20

Fenc

e H

eigh

t

Pallet Qty. 75 75 75 75 75 75 75 75 75 75 75 75

▶ ▶

A 5/16"-18 x 1.25" Carriage Bolt

D 5/16" Flat Washer

C 5/16"-18 Flange Nut

Slot Hardware - Option 1

H 3/8"-16 x 1.69" TriLobe

K 3/8" Flat Washer

J 3/8"-16 Hex Nut

Slot Hardware - Option 2

H 3/8"-16 x 1.69" TriLobe = Qty. 4 for all tracks

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.56

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

MATRIX ALPHA COATED® | T-TRACK / INFILL COVERS

Item Number # of Slots Carriage Bolt Option TriLobe Option

MAXTC-4.5 12 A, D, C H, K, J

MAXTC-7 16 A, D, C H, K, J

MAXTC-7.5 16 A, D, C H, K, J

MAXTC-8 16 A, D, C H, K, J

MAXTC-8.5 16 A, D, C H, K, J

MAXTC-9 20 A, D, C H, K, J

MAXTC-9.5 20 A, D, C H, K, J

MAXTC-10 20 A, D, C H, K, J

MAXTC-10.5 20 A, D, C H, K, J

MAXTC-11 24 A, D, C H, K, J

MAXTC-11.5 24 A, D, C H, K, J

MAXTC-12 24 A, D, C H, K, J

A

H

DC

Page 9: ALPHA COATED

MATRIX ALPHA COATED® | RAILS

HARDWARE INFORMATION FOR T-TRACKS

G #12-14 x 3/4" Tek Screw

E 5/16"-18 x 1.25" Elevator Bolt = 1 ea.

F 5/16"-18 x 3.50" Elevator Bolt = 1 ea.

C 5/16"-18 Flange Nut = 2 ea.

G #12-14 x 3/4" Tek Screw = 1 ea.

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.57

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

MATRIX ALPHA COATED® | INFILL HANGER BRACKET

DESCRIPTION ITEM NUMBER SACK QTY WEIGHT

Infill Hanger BracketMAXB22H-SCK 92 0.22 lbs

MAXB22 12 0.22 lbs

LENGTH ITEM NUMBER BUNDLE QTY WEIGHT

24' MAX24 64 37.03 lbs

MATRIX ALPHA COATED® | RAIL SPLICE

DESCRIPTION ITEM NUMBER BOX QTY WEIGHT

Rail Splice MAXS 32 1.08 lbs

Quantity of rails varies per fence height.

• 7' thru 10' = 3 rails • 10.5' thru 12' = 4 rails • 12.5' thru 14.5' = 4 rails • 15' = 5 rails

Used to join rails. Quantity required to match rail quantity.

NOTE: HARDWARE NOT INCLUDED, SEE FASTENER SECTION

The infill sheets are hung using 2 hanger brackets on the top rail and 3 hanger brackets per rail on the remaining lower rails.

NOTE: HARDWARE NOT INCLUDED, SEE FASTENER SECTION

2" SQ. X 16GA.

FITS 2" X 2" RAIL

E

F

C

G

C

3.6

= 2 Ea.

Page 10: ALPHA COATED

POST

RAIL PARALLEL WITH GRADE

B 5/16"-18 x 3.50" Carriage Bolt = 1 ea.

C 5/16"-18 Flange Nut = 1 ea.

G #12-14 x 3/4" Tek Screw = 3 ea.

B 5/16"-18 x 3.50" Carriage Bolt = 1 ea.

C 5/16"-18 Flange Nut = 1 ea.

G #12-14 x 3/4" Tek Screw = 3 ea.

G

G

C

GB

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.58

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

DESCRIPTION ITEM NUMBER PKG QTY WEIGHT

Post On Grade Bracket MAXSB 39 0.26 lbs

MATRIX ALPHA COATED® | POST BRACKETS

DESCRIPTION ITEM NUMBER PKG QTY WEIGHT

6" x 6" Post BracketMAXB66W-SCK 20 0.71 lbs

MAXB66W 4 0.71 lbs

DESCRIPTION ITEM NUMBER PKG QTY WEIGHT

3" x 6" Post BracketMAXB36W-SCK 28 0.58 lbs

MAXB36W 4 0.58 lbsPost Bracket quantities to match number of rails per post.

NOTE: HARDWARE NOT INCLUDED, SEE FASTENER SECTION

Post Bracket quantities to match number of rails per post.

NOTE: HARDWARE NOT INCLUDED, SEE FASTENER SECTION

Post on Grade Brackets to be used at post when grade angle exceeds 8°.

NOTE: USES HARDWARE FROM EXISTING POST BRACKET

C G

G

BG

Page 11: ALPHA COATED

Item

Num

ber

MA

XCB

-4.5

MA

XCB

-7

MA

XCB

-7.5

MA

XCB

-8

MA

XCB

-8.5

MA

XCB

-9

MA

XCB

-9.5

MA

XCB

-10

MA

XCB

-10.

5

MA

XCB

-11

MA

XCB

-11.

5

MA

XCB

-12

7 12.8

7.5 13.7

8 14.6

8.5 15.5

9 16.4

9.5 17.3

10 18.2

10.5 19.2

11 20.1

11.5 21.0

12 22.0

12.5 8.2 3 14.6

13 8.2 15.5

13.5 8.2 16.4

14 8.2 17.3

14.5 8.2 18.2

15 8.2 19.2

Fenc

e H

eigh

t

CD

A

H

DC

A

A 5/16"-18 x 1.25" Carriage Bolt

D 5/16" Flat Washer

C 5/16"-18 Flange Nut

Slot Hardware - Option 1

H 3/8"-16 x 1.69" TriLobe

K 3/8" Flat Washer

J 3/8"-16 Hex Nut

Slot Hardware - Option 2

H 3/8"-16 x 1.69" TriLobe = Qty. 4 for all tracks

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.59

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

MATRIX ALPHA COATED® | POST BRACKETS MATRIX ALPHA COATED® | CORNER BRACKET

CORNER BRACKETS

HARDWARE INFORMATION FOR CORNER BRACKETS

Item Number # of Slots Carriage Bolt Option TriLobe Option Extra TriLobe "H" Qtys for grounding

MAXCB-4.5 10 A, D, C H, K, J 2

MAXCB-7 14 A, D, C H, K, J 4

MAXCB-7.5 14 A, D, C H, K, J 4

MAXCB-8 14 A, D, C H, K, J 4

MAXCB-8.5 14 A, D, C H, K, J 4

MAXCB-9 16 A, D, C H, K, J 4

MAXCB-9.5 16 A, D, C H, K, J 4

MAXCB-10 16 A, D, C H, K, J 4

MAXCB-10.5 16 A, D, C H, K, J 4

MAXCB-11 18 A, D, C H, K, J 6

MAXCB-11.5 18 A, D, C H, K, J 6

MAXCB-12 18 A, D, C H, K, J 6

Each bracket has round holes for grounding fasteners. See chart for quantity/bracket.

NOTE: Corner Brackets are used to join infill sheets at corners. The quantity should equal the number of corners of the site.

Page 12: ALPHA COATED

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.60

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

MATRIX ALPHA COATED® | FASTENERS

DESCRIPTION ITEM NUMBER BOX QTY WEIGHT

Corner/Grade Change Hinge Hardware Box

MAUCGB 12 0.47 lbs

Kit includes: 2 Ea. #90-130-15405 (Max Corner Hinge), 2 Ea. #18991 (3/8" x 7/8" Flat Washer), 1 Ea. #19024 (3/8-16 18-8 Hex Nut), 1 Ea. #2-0097-U (3/8"-16 x 1-1/2" Hex Bolt), 2 Ea. #1-0067-U (#12 -14 x 3/4" Tek Screw)

NOTE: The quantity used at each corner/grade change is equal to the number of rails at that location.

MATRIX ALPHA COATED ® | CORNER/GRADE CHANGE HINGE

Corner/Grade Change Hinge is used to join rails at any corner/grade change between 0°-90°.

A B C D E F G

H J K

5/16"-18 X 1.25"CARRIAGE BOLT, SS

5/16"-18 X 3.50"CARRIAGE BOLT, SS

5/16"-18 FLANGE NUT, SS

5/16"FLAT WASHER, SS

5/16"-18 X 1.25"ELEVATOR BOLT, SS

5/16"-18 X 3.50"ELEVATOR BOLT, SS

#12-14 x 3/4"TEK-SCREW, SS

3/8"-16 x 1.69TRILOBE, SS

3/8"-16HEX NUT, SS

3/8"FLAT WASHER, SS

Universal Character Description HDG Black CC142

A 5/16"-18 x 1.25" Carriage Bolt 2-0090-UBKT 2-0090-1BKT 2-0090-UBKT

B 5/16"-18 X 3.50" Carriage Bolt 2-0086-UBKT 2-0086-1BKT 2-0086-UBKT

C 5/16"-18 Flange Nut 3-0051-UBKT 3-0051-1BKT 3-0051-UBKT

D 5/16" Flat Washer 4-0049-UBKT 4-0049-1BKT 4-0049-UBKT

E 5/16"-18 x 1.25" Elevator Bolt 2-0102-UBKT 2-0102-1BKT 2-0102-UBKT

F 5/16"-18 x 3.50" Elevator Bolt 2-0103-UBKT 2-0103-1BKT 2-0103-UBKT

G #12-14 x 3/4" Tek Screw 1-0067-UBKT 1-0067-1BKT 1-0067-UBKT

H 3/8"-16 x 1.69 TriLobe 1-0049-142BKT 1-0049-1BKT 1-0049-142BKT

J 3/8"-16 Hex Nut 3-0038-1BKT 3-0038-1BKT 3-0038-1BKT

K 3/8" Flat Washer 4-0050-UBKT 4-0050-1BKT 4-0050-UBKT

Page 13: ALPHA COATED

HEAVY

HEAVY

LIGHT

LIGHT

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.61

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

SIZE DEPTH ITEM NUMBER WEIGHT

3" x 6" x .083 Varies MAXP36L* Varies

3" x 6" x 3/16" Varies MAXP36H* Varies

6" x 6" x 3/16" Varies MAXP66H* Varies

MATRIX ALPHA COATED ® | BURY POSTS

MATRIX ALPHA COATED® | PLATED POSTS

*= VARIABLE LENGTH OPTIONS AVAILABLE

NOTE: Post length is dependent upon, but not limited to: soil conditions, wind load requirement, fence height, post spacing & infill used. Please consult your Ameristar representative for correct post length.

* = VARIABLE LENGTH OPTIONS AVAILABLE

NOTE: Post length is dependent upon, but not limited to: soil conditions, wind load requirement, fence height, post spacing & infill used. Please consult your Ameristar representative for correct post length.

SIZE POST LENGTH ITEM NUMBER WEIGHT

3" x 6" x .083 Varies MAXP36PL* Varies

3" x 6" x 3/16" Varies MAXP36PH* Varies

6" x 6" x 3/16" Varies MAXP66PH* Varies

Page 14: ALPHA COATED

MATRIX ALPHA COATED® | BURY TECH POST

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.62

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

MATRIX ALPHA COATED® | TECH POST ACCESS COVER PLATE

DESCRIPTION ITEM NUMBER BOX QTY WEIGHT

Tech Post Access Cover Plate MAXTPCP 3 5.55 lbs

MATRIX ALPHA COATED® | PLATED TECH POST

SIZE HEIGHT DEPTH ITEM NUMBER WEIGHT

6" x 6" x 3/16" Varies Varies MAXTP66H*[(XXX)H(YYY)D] Varies

SIZE HEIGHT ITEM NUMBER WEIGHT

6" x 6" x 3/16" Varies MAXTP66H*[(XXX)H] Varies

XXX = VARIABLE HEIGHT OPTIONS AVAILABLE YYY = VARIABLE DEPTH OPTIONS AVAILABLE

XXX = VARIABLE HEIGHT OPTIONS AVAILABLE

3 plates per post.

* = VARIABLE LENGTH OPTIONS AVAILABLE

NOTE: Post length is dependent upon, but not limited to: soil conditions, wind load requirement, fence height, post spacing & infill used. Please consult your Ameristar representative for correct post length.

* = VARIABLE LENGTH OPTIONS AVAILABLE

NOTE: Hardware not included, see fastener section.1 Box per Tech Post. Each box contains 3 plates.12 Ea. #1-0049-142BKT (3/8"-16 x 1.69" Screw)

Page 15: ALPHA COATED

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.63

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

CAP SIZE ITEM NUMBER PKG QTY WEIGHT

3" X 6" sq. MAUCAP36-SCK 28 0.39 lbs Ea.

3" X 6" sq. MAUCAP36 6 0.39 lbs Ea.

6" X 6" sq. MAUCAP66-SCK 20 0.62 lbs Ea.

6" X 6" sq. MAUCAP66 4 0.62 lbs Ea.

3" X 6" CAPS

6" X 6" CAPS

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Camera Arm MAXCA 3" X 7" X 1/4" x 24" 35.04 lbs

Camera Arm Hardware MAXCA-HDW

MATRIX ALPHA COATED ® | POST CAPS

MATRIX ALPHA COATED® | ACCESSORIES

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Davit Arm MAULA66 7.1875" x 6.625" 6.08 lbs

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Spike Wall Topper MAUST10 6.75" X 121.75" L 12.54 lbs

NOTE: #MAXCA-HDW Hardware Kit includes: 4 Ea. #90-133-15409 (5" Round x 14GA Steel Plate), 14 Ea. #1-0049-X (3/8" x 1.69" Screw), and 1 Ea #90-133-15410 (2" x 3-1/2" x 14GA. Steel Plate)

NOTE: #MAXLA66-HDW Hardware Kit includes: 2 Ea. #3-0044-U (1/2" Stainless Steel Nut), 2 Ea. #2-0093-U (1/2" x 7-1/2" Stainless Steel Hex Bolt), and 4 Ea. #17916 (1/2" Stainless Steel Washer)

Spike Wall Topper uses existing infill to rail fasteners for attachment, as a standard.

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Line Barb Arm PBAU-L 18" 2.36 lbs

End/Corner Barb Arm MBAU-FC 18" 5.08 lbs

Hot dipped galvanized. 1 line barb arm required at each intermediate post. Corner barb arms required at corner posts.

NOTE: FASTENERS NOT INCLUDED, HARDWARE REQUIRED MAUCAP36: 1 Ea. #1-0067-XBKT (#12 Tek Screw)MAUCAP66: 1 Ea. #1-0067-XBKT (#12 Tek Screw)

NOTE: If barb arms are to be installed, add 6" to intermediate and corner posts.

NOTE: Hardware not included, see fastener section. 4 Ea. #1-0049-142BKT (3/8"-16 x 1.69" Screw), 4 Ea. #18991-BKT (3/8" Flat Washer)

Page 16: ALPHA COATED

MATRIX ALPHA COATED® | ANIMAL SHIELD

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.64

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Bottom Gate Sweep Aluminum Brush Kit BGSB96 96" L 4 lbs

KIT CONTAINS: (1) 96" Aluminum Brush Holder (90-552-15770 | (1) 96" Length 3" Nylon Crimped Strip Brush (90-552-15771) | (9) #12-14 x 3/4" Stainless Steel Tek Screw (1-0067-U)

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Vertical Gate Animal Mitigation VGAMX144 6" W x 72" L 24 lbs

CONTAINS: (1) Animal Shield Vertical Bracket (90-552-15810) | (2) 1/4" Thick x 6" W x 72" L 60A Neoprene Strip (90-552-15809) | (20) 3/8"-16 x 1.69" GR5 Screw (1-0049-X) | (10) 3/8" Stainless Steel Nut (HB537)

CONTAINS: (1) Flat Animal Shield (90-552-15655 | (30) 3/8"-16 x 1.69" GR5 Screw (1-0049-X) | (30) 3/8" Stainless Steel Nut (HB537)

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Gate Animal Shield (Flat) ASGX 30" W x 96" L 54 lbs

DESCRIPTION ITEM NUMBER SIZE WEIGHT

Animal Shield Line Kit ASLX 62" L 41.15 lbs

Animal Shield Corner Kit ASCX 12.75" x 40.125" x 10" 21.00 lbs

NOTE: #ASLU Animal Shield Line Kit includes: 1 Ea. #90-552-15568 (Line), 2 Ea. #90-130-15569 (Bracket) 10 Ea. #10049-X (3/8"-16 x 1.69 GR5 Screw), 10 Ea. #HX537 (3/8 Stainless Steel Nut), and 3 Ea. #1-0067-X (#12-14 x 3/4 Stainless Steel Tek Screw). #ASCU Animal Shield Corner Kit includes: 1 Ea. #90-552-15610 (Corner Cover), 1 Ea. #90-552-15611 (Corner Plate), 6 Ea. #90-130-15612 (Corner Bracket, and 12 Ea. #1-0049-X (3/8"-16 x 1.69 GR5 Screw)

ASLU - Installs along upper portion of fence at desired height from grade (field modifications may be required). One kit required every 62 inches.

ASCU - Installs at upper portion of fence adjacent to ASLU at each corner (field modifications may be required).

Installs along bottom of gate to mitigate gaps (field modification may be required). One kit required every 96 inches.

Installs along upper portion of fence at desired height from grade (field modifications may be required). One kit required every 62 inches.

Installs along upper portion of gate, matching height of adjacent ASLU (field modification may be required). One kit required every 96 inches.

Page 17: ALPHA COATED

MATRIX ALPHA COATED® | CONSTRUCTION SPECIFICATION 32 31 00

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.65

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

PART 1 - GENERAL1.01 WORK INCLUDEDThe contractor shall provide all labor, materials and appurtenances necessary for installation of the industrial galvanized steel perimeter enclosure grid fence system defined herein at (specify project site).

1.02 RELATED WORKSection ___ ___ - EarthworkSection ___ ___ - Concrete

1.03 SYSTEM DESCRIPTIONThe manufacturer shall supply a steel perimeter enclosure grid framing system of the Matrix Alpha Coated® design, (specify mesh filler, Table 1) style. The system shall include all components (i.e., mesh filler, mesh retainer channels, rails, posts, gates and hardware) required.

1.04 QUALITY ASSURANCEThe contractor shall provide laborers and supervisors who are thoroughly familiar with the type of construction involved and materials and techniques specified.

1.05 REFERENCES• ASTM A653/A653M - Standard Specification for Steel

Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the Hot-Dip Process• ASTM A123/A123M - Standard Specification for Zinc

(Hot-Dip Galvanized) Coatings on Iron and Steel Products

• ASTM B117 - Practice for Operating Salt-Spray (Fog) Apparatus

• ASTM D523 - Test Method for Specular Gloss• ASTM D714 - Test Method for Evaluating Degree of

Blistering in Paint• ASTM D1654 - Test Method for Evaluation of Painted

or Coated Specimens Subjected to Corrosive Environ-ments

• ASTM D2244 - Test Method for Calculation of Color Differences from Instrumentally Measured Color Coordinates

• ASTM D2794 - Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Im-pact)

• ASTM D3359 - Test Method for Measuring Adhesion by Tape Test

• ASTM D6695 - Standard Practice for Xenon-Arc Expo-sures of Paint and Related Coatings

• ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,

Profiles and Tubes• ASTM F2548 – Expanded Metal Fence Systems for

Security Purposes

• ASTM F2453/F2453M – Welded Wire Mesh Fence Fabric

• IEEE P80/D10 – Draft Guide for Safety in AC Substa-tion Grounding

• IEEE 142-1991 – IEEE Recommended Practice for Grounding of Industrial and Commercial Power

Systems• IEEE 81-2012 – IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials for a Ground System• ASTM F2781 – Testing Forced Entry, Ballistic and Low

Impact Resistance of Security Fence Systems.

1.06 SUBMITTALThe manufacturer's submittal package shall be provided prior to installation.

1.07 PRODUCT HANDLING AND STORAGEUpon receipt at the job site, all materials shall be checked to ensure that no damage occurred during shipping or han-dling. Materials shall be stored in such a manner to ensure proper ventilation and drainage, and to protect against damage, weather, vandalism and theft.

1.08 PRODUCT WARRANTYPowder coated surface on all mesh and framework (i.e. rails and posts) is guaranteed under normal and proper usage, against cracking, peeling, chipping or corroding for a period of ten (10) years from the original purchase date. Matrix Alpha Coated is also guaranteed for the same pe-riod of time against defects in workmanship or materials. See product specific warranty for additional details.

1.09 PRODUCT TESTING & COMPLIANCE Fence system shall be tested by third party professional engineer to IEEE P80/D10, IEEE 142-1991 and IEEE 81-2012. Fence system shall be tested to ASTM stan-dard F2781 for forced entry by third party certified testing organization.

Test summary documentation shall be made available upon request.

PART 2 - MATERIALS2.01 MANUFACTURERThe fence system shall conform to perimeter enclosure grid framing system of the Ameristar Matrix Alpha Coated design, (specify mesh filler, Table 1) style, manufactured by Ameristar Perimeter Security USA Inc. in Tulsa, Okla-homa.

Page 18: ALPHA COATED

SEE REFERENCED TABLES ON THE FOLLOWING PAGE

MATRIX ALPHA COATED® | CONSTRUCTION SPECIFICATION 32 31 00

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.66

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

2.02 MATERIALA. Steel material for perimeter enclosure grid framework (i.e. rails and posts), shall have a minimum yield strength of 45,000 psi (310 MPa).

B. Steel material for bury posts 3” x 6" x .083 shall be hot-dip galvanized to meet the requirements of ASTM A653/A653M with a minimum zinc coating weight of 1 oz/ft2, Coating Designation G100.

C. Steel material for bury posts 3” x 6” x 3/16” wall shall be hot-dip galvanized to meet the requirements of ASTM A653/A653M with a minimum zinc coating weight of 1.85 oz/ft2, Coating Designation G185.

D. Steel material for plated posts 3” x 6” x .083 shall be hot-dip galvanized to meet the requirements of ASTM A123/A123M with a minimum zinc coating weight of 1 oz/ft2, Coating Thickness Grade 45.

E. Steel material for plated & bury posts 3” x 6” x 3/16” wall., 6” x 6” x 3/16” wall., shall be hot-dip galvanized to meet the requirements of ASTM A123/A123M with a minimum zinc coating weight of 1.7 oz/ft2, Coating Thick-ness Grade 75.

F. Steel material for rails 2” x 2” x 16GA. shall be hot-dip galvanized to meet the requirements of ASTM A653/A653M with a minimum zinc coating weight of 1 oz/ft2, Coating Designation G100.

G. Rails shall be a minimum 2” SQ. x 16GA. and shall run continuous along front face of Matrix Alpha Coated fence system. Rail changes in grade and direction shall be accomplished by Matrix Alpha Coated hinged bracket. Hinged bracket shall fully engage each end of rail. Rail sections shall be joined by internal rail splice and secured using fastener. Rail to post attachment brackets shall be a minimum .875” wide x 14GA.

H. Fence post shall meet the minimum system require-ments. Post options include 3” x 6” x .083, 3” x 6” x 3/16” or 6” SQ. x 3/16”. Post size shall be based upon system design requirements.

I. The cross-sectional shape of the T-track shall conform to the manufacturer’s mesh trim design with outside cross-section nominal dimensions of 3.5” x .5” minimum. Alu-minum material for T-track shall conform to the require-ments of ASTM B221, alloy designation 6063-T5.

J. Matrix Alpha Coated mesh filler material shall comply with one of the options listed in Table 1.

2.03 FABRICATIONA. Posts shall be pre-cut to specified lengths. Rails shall be pre-cut to manageable length and adjoined using splice coupling and fastener.

B. T-track cover shall be precut to specified lengths and pre-drilled for mesh attachment. T-track shall be affixed vertically to mesh to accommodate the joining of specified filler material.

C. Mesh filler panels shall be pre-cut to match fence height. Each mesh panel shall be affixed to top rail using a minimum of 2 infill hanger brackets. Mesh infill shall be affixed at each remaining rail, minimum of 3 connection points per mesh panel at middle and bottom rails.

D. Integrated technology post shall be pre-manufactured with access ports strategically located and have predrilled holes for attachment. Technology post base shall be a minimum 6” x 6” SQ., and either 18' or 20' above grade.

E. The manufactured galvanized framework shall be subjected to the PermaCoat® thermal stratification coating process (high-temperature, in-line, multi-stage, multi-layer) including, as a minimum, a six-stage pretreatment/wash, an electrostatic spray application of an epoxy base, and a separate electrostatic spray application of a polyester finish. The base coat shall be a ther-mosetting epoxy powder coating (gray in color) with a minimum thickness of 2 mils (0.0508mm). The topcoat shall be a “no-mar” TGIC polyester powder coat finish with a minimum thickness of 2 mils (0.0508mm). The color shall be (specify Black, Bronze, White, or Desert Sand). The stratification-coated framework shall be capable of meeting the performance requirements for each quality characteristic shown in Table 2.

F. Pedestrian swing gates shall match fence system. Gate shall be pre-drilled to accept appropriate hardware set. Infill frames shall be fabricated as a single unit. Frame shall be of welded construction inset with mesh filler, attachment to gate frame by means of security fasteners. Gate jamb frame shall be fully welded consisting of 3” x 12GA. square tubing for main jamb, 1” SQ. gate stop, and strike mounting block, with gate stop bumpers. Jamb to include an electrical access point with conduit point of connection. Electrical connection to gate by means of Power Transfer connection mounted in jamb and

Page 19: ALPHA COATED

MATRIX ALPHA COATED® | CONSTRUCTION SPECIFICATION 32 31 00

gate. Gate shall be pre-assembled. Gate threshold to be mounted with fasteners allowing for placement below grade or removal after gate installation. Gate hardware to consist of exterior rated devices. Gate and hardware to be pre-assembled prior to shipping. Gate opening shall be designed to accommodate a 48” clear opening.

G. Sliding cantilever gates shall match fence system. Slide gate shall be a component design using tracks, up-rights, mesh filler, hardware, fittings, and fasteners. Gate installation shall comply with latest ASTM F2200 stan-dards for automated gates.

H. Optional – Animal mitigation shield shall be securely mounted to top portion of fence and gate system. Ani-mal shield shall provide positive deterrent from nuisance animals intruding into protected areas. System shall be installed along the upper most portion of the fence and gate system and throughout the entire perimeter includ-ing all corners and/or changes in fence direction. Animal mitigation system shall be evaluated and recommended by an accredited herpetologist for mitigating intrusion of nui-sance animal’s i.e. snakes, raccoons, squirrels, iguanas, rodents of unusual size, possums, cat species & nutria.

I. Optional – Barbed wire deterrent shall be installed at top of fence and gate system. Barbed wire deterrent shall have a minimum of 3 strands and be affixed to barb arms. Barb arms shall be securely attached to each line and terminal posts.J. Optional –Spike Deterrent Strips shall be securely attached to the top of fence and gate system. Spike Deterrent strips shall be 12GA. (.075”) galvanized steel, spike sets shall alternate between two heights every 2", spike set heights shall be 2.75" and 3.5". Spike deterrent strips shall affix atop fence and gate system not exceeding a distance between each strip section of 2".

PART 3 - EXECUTION3.01 PREPARATIONAll new installation shall be laid out by the contractor in accordance with the construction plans.

3.02 FENCE INSTALLATIONFence post shall be spaced to meet system requirements. Fence posts shall not exceed 12' on center. Fence frame-work and mesh filler shall be attached to system posts with fasteners supplied by the manufacturer. Posts shall

be installed per system drawings (Note: In some cases, local restrictions of freezing weather conditions may require a greater depth). The “Earthwork” and “Concrete” sections of this specification shall govern material require-ments for the concrete footer. Posts setting by other methods such as plated posts or grouted core-drilled foot-ers are permissible only if shown by engineering analysis to be sufficient in strength for the intended application.

3.03 FENCE INSTALLATION MAINTENANCEWhen cutting/drilling steel and aluminum system com-ponents, adhere to the following steps to seal exposed surfaces; 1) Remove all metal shavings from cut area. 2) Apply fence system manufacturer provided zinc-rich paint to thoroughly cover cut edge and/or drilled hole; let dry. Failure to seal exposed surfaces per these steps above will negate warranty. Use of non-Ameristar parts or compo-nents will negate the manufactures’ warranty.

3.04 GATE INSTALLATIONGate posts shall be spaced according to the manufactur-ers’ gate drawings, dependent on standard out-to-out gate leaf dimensions and gate hardware selected. Type and quantity of gate hinges shall be based on the application; weight, height, and number of gate cycles. The manu-facturers’ gate drawings shall identify the necessary gate hardware required for the application. Gate hardware shall be provided by the manufacture of the gate and shall be installed per manufacturer’s recommendations.

3.05 INSTALLATION TESTINGCompleted installation shall be tested for compliance to applicable IEEE Grounding Standards by qualified third party.

3.06 CLEANINGThe contractor shall clean the job site of excess materials; post-hole excavations shall be scattered uniformly away from posts.

SEE REFERENCED TABLES ON THE FOLLOWING PAGE

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.67

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

Page 20: ALPHA COATED

MATRIX ALPHA COATED® | CONSTRUCTION SPECIFICATION 32 31 00

Table 2 - Coating Performance Requirements

Quality Characteristics ASTM Test Method Performance Requirements

Adhesion D3359 – Method BAdhesion (retention of coating) over 90% of test area (tape and knife kit test).

Corrosion Resistance B117, D714, D1654Corrosion resistance over 3,500 hours (scribed per D1654; failure mode is accumulation of 1/8" coating loss from scribe or medium #8 blisters)

Impact Resistance D2794 Impact resistance over 60" lb. (forward impact using 0.625" ball).

Weathering Resistance D822 D2244, D523 (60o method)Weathering resistance over 1,000 hours (failure mode is 60% loss of gloss or color variance of more than 3 delta-E color units).

Effective: 04/26/21

| TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM7.68

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ALPHA COATED ® | MATRIX ALPHA ® | MATRIX ®

Table 1 - Matrix Alpha Filler Options

Trade Name Product Description Screening

X-Span™ Expanded Metal Mesh .5" x #13R - (.188 strand width) Modified / ASTM F2548 75% screening

.5" x #13R / ASTM F2548 43% screening

.75" x #9F / ASTM F2548 - (HDG only) 37% screening

X-Screen™ Louvered Mesh (Steel) 1.5" x #14 - (HDG only) 94% screening

WireWorks™ Welded Wire Mesh .5" x 3" x 8GA. / ASTM F2453/F2453M 37% screening

.5" x 3" x 6GA. / ASTM F2453/F2453M - (HDG only) 43% screening

Page 21: ALPHA COATED

Effective: 04/26/21

TO PLACE YOUR ORDER CALL 888-333-3422 | VISIT AMERISTARFENCE.COM | 7.69

MATRIX ALPHA COATED ®

| GROUNDABLE HIGH SECURITY PERIMETER ENCLOSURE GRID MATRIX ® | MATRIX ALPHA ® | MATRIX ALPHA COATED ®

MATRIX ALPHA COATED® | LIMITED WARRANTY

Matrix Alpha Coated® Perimeter Enclosure Grid Fence System by Ameristar® is manufactured from the highest quality materials by skilled craftsmen to meet the highest standards of workmanship in the indus-try.

The powder coated surface on all mesh and framework (i.e. rails and posts) by Ameristar is guaranteed under normal and proper usage, against cracking, chipping, peeling and corroding for a period of ten (10) years from the original purchase date (minimum threshold of 5% surface affected on overall project). Nor-mal and proper usage does not include physical damage, abrasion or exposure to salty environments to the protective coating.

Matrix Alpha Coated Perimeter Enclosure Grid Fence System is also guaranteed for the same period of time against defects in workmanship or materials.

Should any mesh or framework manufactured by Ameristar fail in accordance with any of the above con-ditions, Ameristar warrants to the original purchaser their redemption through replacement, renewal or issuance of a pro-rated credit. The decision as to which method of redemption is allowed is solely at the discretion of Ameristar.

If pro-rated allowance is the chosen alternative, the amount will be based on the total number of years under warranty from date of purchase to date of claim, based on the original cost of framing materials found to be defective. Notice of failure under the conditions of this warranty shall be sent to Ameristar or its authorized representative, in writing, together with proof of purchase and shall specify the nature of the defect and when it was first observed. When cutting, drilling or modifying Matrix Alpha Coated compo-nents, immediately seal the exposed surfaces by 1) Removing all metal shavings from cut area, 2) Apply two (2) coats of zinc finish (finish paint must have a minimum 69% zinc) to thoroughly cover cut edge and/or drilled areas; let dry.

Failure to seal exposed surfaces per the above steps will negate warranty. If the contractor uses non Ameri-star parts/components, this will negate the warranty. Should the fence be improperly installed, Ameristar shall not be responsible for guaranteed performance or appearance of the material. Neither does this guar-antee apply when failure or damage is due to improper use or application, abuse or misuse, salty environ-ments, vandalism or acts of God. Ameristar reserves the right to inspect the material to determine validity of the claim.

Upon validation of the claim by Ameristar or its authorized representative, redemption by replacement, renewal or issuance of a pro-rated credit shall be made by Ameristar. Reimbursement for the costs of removal and installation of materials are not included in the guarantee, nor will Ameristar provide those services.

The above constitutes the complete warranty by the manufacturer. No other agreement, written or implied, is valid. Ameristar does not authorize any other person or agent to make any other express warranties. Ameristar neither assumes nor authorizes any other person or agent to assume any other liability in con-nection with Matrix Alpha Coated Perimeter Enclosure Grid Fence System. Some jurisdictions do not allow limitations on how long an implied warranty lasts, nor do they allow an exclusion or limitation of incidental or consequential damages; therefore, the limitations and exclusions noted herein may not apply.