aluminum terminal boxes shorv ccfe€¦ · gost 30852.20-2002 tr cu 012/2011 gost iec...
TRANSCRIPT
SHORV CCFE
26
Alu
min
um
term
inal
bo
xes
• Over 25 years of flameproof joint service life• High resistance of SHORV aluminum alloy enclosures to hydrogen sulfide
exposure• Wide choice of dimension types of enclosures• Enclosures are tested in conditions up to -60°C (special version up to
-75°C)• Internal surface without coating ensures increased thermal conductivity • Enclosure can be manufactured with window• Can be manufactured from highly corrosion-resistant stainless
chrome-nickel casting steel
MARKING
1Ex d IIС T6...T4 Gb X
1Ex d IIB+H2 T6...T4 Gb
1Ex d [ia] IIB+H2 T6...T4 Gb
1Ex d [ib] IIB+H2 T6...T4 Gb
1Ex d [ia] IIC T6...T4 Gb X
1Ex d [ib] IIC T6...T4 Gb X
Ex tb IIIC T70°С...T135°С Db
MINING EQUIPMENT MARKING
PB Ex d I Mb
PB Ex d [ib] I Mb
РВ Ex d [ia] I MbРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004Maritime Register Type Approval Certificate No. 17.12692.120TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666VTT 17 ATEX 047U (for enclosure only)
CODESGOST 14254-96 (IEC 529-89)GOST R IEC 60079-31-2010GOST 12.2.007.0-75GOST R IEC 60079-0-2011GOST IEC 60079-1-2011GOST 30852.0-2002GOST 30852.10-2002 (IEC 60079-11:1999)GOST 30852.20-2002TR CU 012/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3 Ch. 7.4 OD 5.2-093-2004
TECHNICAL CHARACTERISTICS
Installation
Category I for firedamp and dust;Category II for gas subgroup IIA, IIB+H2, IIC (except for acetylene); zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Facilities under Russian Maritime Register of Shipping supervision;Dangerous production facilities
Maximum voltage, V
~1000 / A250V ~3300 (SHORV423229...SHORV896735) ~10000 (SHORV654533...SHORV1077740)~1140В / A250V (for mining explosion-proof version)
Maximum current, A
650, 1500 (for ~1000, A250)
Sealant
Silicone rubber (in cover groove) for IP67, flange sealant PG-FLANEC for IP68, silicone sealant PG-SMAZKA for IP66
Grounding
2 stainless steel ground clamps (inner and outer)
Installation inside enclosure
4 racks for mounting panel installation
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6667 68
HOLOD
SHORV CCFE
27
Alu
min
um
term
inal
bo
xes
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Cover fixation on hinges (for SHORV281811, for other sizes of SHORV enclosures hinges are by default)
/PETLYA
Drain plug for condensate removal /DKUV
Breather plug for moisture removal /VKUV
Marine version /MORE
Version for minimum operating temperature -75°C /HOLOD
Version for tropics with protection against bugs /TERMITY
Special version for nuclear facilities of nuclear power plants “Small leak” /MALAYA TECH
Earthquake-resistant version /MSK-64
Acceptance by customer /PRIEMKA
Nameplate with inscription as per customer’s specification /NADPIS «_»
Stainless steel mounting plate /NP
Nameplates with light reflecting coating /SVP
External surface coating as per customer’s specification /RAL (code)
DESCRIPTION MARKING
Bolt with seal /PLOMBA
Device for connection of cable screens /EKRAN
Neutral bus bar /SHINA N
Internal ground bus bar /SHINA Z
Phase bus bar /SHINA PH
Terminal jumpers as per customer’s diagram /SCHEMA
Marking of terminals as per customer’s diagram /MARK
Aluminum alloy mounting plate /ALP
Internal thermal insulation /TEPLOISOLYATSIYA
Heating for automatic devices /OBOGREV
Anti-condensation coating /AP
Degree of protection IP67 /IP67
Captive bolts for cover fastening /NBK
Radiator cooling system /RADIATOR
Alignment pin (for SHORV896746 and larger) /SHTIFT
OVERALL AND MOUNTING DIMENSIONS
Dimensions of SHORV enclosures
Dimension type of enclosure
Dimensions, mm
Mass, kgExternal Internal Standard fastening Fastening with brackets
A B C a b c S S1 d e f D E FSHORV281811 282 182 118 212 112 74 14 14 160 124 М6 160 155 9 6,3SHORV302021 304 204 211 240 140 163 14 14 230 130 М8 230 210 9 8,6SHORV422221 424 224 213 359 159 165 15 14 350 150 М8 350 230 9 13,6SHORV362827 364 284 275 300 220 217 20 14 290 210 М8 290 290 9 17,25SHORV362821 364 284 215 300 220 157 20 14 290 210 М8 290 290 9 14.97SHORV423229 425 325 297 361 261 233 24 14 350 250 M10 350 330 11 25,3SHORV423222 425 325 226 361 261 163 24 14 350 250 M10 350 330 11 20,7SHORV464621 461 461 213 391,5 391,5 150 22 16,5 310 310 M10 310 460 11 34,5SHORV573931 576 396 318 506 326 247 26 20 360 236 М10 360 376 11 48.1SHORV573926 576 396 268 506 326 197 26 20 360 236 M10 360 376 11 44.4SHORV654533 650 450 337 570 370 222 16 17,5 550 350 10 550 446 11 59.5SHORV654526 650 450 265 570 370 150 16 16 550 350 10 550 446 11 51.6
SHORV CCFE
28
Alu
min
um
term
inal
bo
xes
Dimension type of enclosure
Dimensions, mm
Mass, kgExternal Internal Standard fastening Fastening with brackets
A B C a b c S S1 d e f D E FSHORV725235 723 523 359 639 439 246 23 18,5 600 400 10 600 505 11 83.8SHORV725224 723 523 249 639 439 136 23 17 600 400 10 600 505 11 71.2SHORV896745 891 671 455 776 556 374 23 29 680 480 М16 680 640 14 173,9SHORV896735 891 671 355 776 556 274 23 28 680 480 М16 680 640 14 150
SHORV1045839 1040 585 393 910 455 315 24 24 790 360 М16 790 530 16 144,2SHORV1077740 1070 770 404 920 620 314 30 24 810 510 М16 810 700 16 229
Mounting panel
Dimensions of mounting panels for SHORV enclosures
Name Dimensions, mm Box type Mass, kgА В a bSH2818Х 206 100 193 53 SHORV281811 —SH3020Х 220 120 180 80 SHORV302021 —SH4222Х 340 140 300 100 SHORV422221 —
SH3628Х 280 200 240 160 SHORV362827SHORV362821 0,435
SH4232Х 340 240 300 200 SHORV423229SHORV423222 0,660
SH4646Х 360 315 360 210 SHORV464621 —
SH5739Х 460 280 440 260 SHORV573931SHORV573926 0,700
SH6545Х 540 340 500 300 SHORV654533SHORV654526 0,750
SH7252Х 605 400 560 360 SHORV725235SHORV725224 —
SH8967Х 720 500 680 460 SHORV896745SHORV896735 0,800
SH10458Х 850 400 790 360 SHORV1045839 —SH10777Х 850 550 820 520 SHORV1077740 0,800
*X – material code: A – aluminum, N – stainless steel.
Table of names matching
Previous international name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
The Customs Union name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
CCFE SHORVCCFE-01P SHORV281811CCFE-1P SHORV302021CCFE-2P SHORV422221CCFE-3P SHORV362827
CCFE-3BP SHORV362821CCFE-4P SHORV423229
CCFE-4BP SHORV423222CCFE-45 SHORV573931
CCFE-45B SHORV573926CCFE-5 SHORV654533
CCFE-5B SHORV654526CCFE-55 SHORV725235
CCFE-55B SHORV725224CCFE-6 SHORV896745
CCFE-6B SHORV896735CCFE-7B SHORV1077740
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNE, KNVZ refer to p. 393
Maximum recommended number of cable glands on sides of SHORV boxes*
Cable gland size code
G, GOST 6357
M, GOST 24705
SHORV281811
SHORV302021
SHORV422221
SHORV362827
SHORV362821
SHORV423229
AG/М
B G/М
A G/М
B G/М
A G/М
B G/М
A G/М
BG/М
A G/М
B G/М
A G/М
BG/М
01 3/8” М16Х1,5 4/4 2/2 12/12 6/6 20/20 8/8 21/21 16/16 15/15 11/11 31/31 23/231 1/2” М20Х1,5 4/4 2/2 11/11 6/6 18/20 8/8 20/21 14/14 14/15 11/11 30/30 21/212 3/4” М25Х1,5 4/4 2/2 8/8 4/4 14/14 5/5 16/16 12/12 10/10 7/7 22/22 16/163 1” М32Х1,5 3/3 2/2 6/6 4/4 10/10 4/4 12/12 9/9 8/8 6/6 15/16 10/124 1 1/4” М40Х1,5 — — 5/5 2/2 7/7 3/3 8/9 6/6 6/6 4/4 12/12 8/95 1 1/2” М50Х1,5 — — 2/2 1/1 5/5 2/2 6/6 5/5 3/3 2/2 9/9 6/66 2” М63Х1,5 — — 2/2 1/1 3/3 1/1 6/6 4/4 3/3 2/2 6/6 5/57 2 1/2” М75Х1,5 — — 2/2 1/1 3/3 1/1 3/3 2/2 2/2 1/1 5/5 4/48 3” М90Х1,5 — — 1/1 1/1 2/2 1/1 2/2 1/1 2/2 1/1 3/3 2/2
Order placement
29
Alu
min
um
term
inal
bo
xes
Cable gland size code
G, GOST 6357
M, GOST 24705
SHORV423222
SHORV464621
SHORV573931
SHORV573926
SHORV654533
SHORV654526
A G/М
B G/М
A G/М
B G/М
A G/М
B G/М
A G/М
B G/М
A G/М
B G/М
A G/М
B G/М
01 3/8” М16Х1,5 20/20 15/15 16/16 16/16 40/40 25/25 30/30 18/18 48/48 30/30 32/32 20/201 1/2” М20Х1,5 20/20 14/15 15/15 15/15 39/40 25/25 28/30 18/18 46/48 29/30 32/32 20/202 3/4” М25Х1,5 14/14 11/11 14/14 14/14 32/32 20/20 23/23 15/15 38/38 22/22 23/23 14/143 1” М32Х1,5 10/10 6/6 10/10 10/10 21/21 13/13 14/14 9/9 25/25 15/16 16/16 10/104 1 1/4” М40Х1,5 8/8 5/6 6/6 6/6 16/17 11/11 12/12 8/8 20/21 12/12 14/14 8/85 1 1/2” М50Х1,5 6/5 4/4 4/4 4/4 11/11 8/8 9/9 6/6 14/14 9/9 8/8 5/56 2” М63Х1,5 4/3 2/2 4/4 4/4 10/10 6/6 6/6 4/3 11/11 6/6 6/6 4/47 2 1/2” М75Х1,5 3/3 2/2 3/3 3/3 6/6 4/4 4/4 2/2 8/8 5/5 5/5 3/38 3” М90Х1,5 2/2 1/1 — — 4/4 2/2 3/4 2/2 5/5 3/3 4/4 2/2
Cable gland size code
G, GOST 6357
M, GOST 24705
SHORV725235
SHORV725224
SHORV896745
SHORV896735
SHORV1045839
SHORV1077740
A G/М
B G/М
A G/М
B G/М
A G/М
B G/М
A G/М
B G/М
A G/М
BG/М
A G/М
B G/М
01 3/8” М16Х1,5 60/60 40/40 28/29 19/19 84/84 61/61 56/56 40/40 70/70 32/32 70/70 46/461 1/2” М20Х1,5 58/58 38/38 27/28 18/18 84/84 60/60 54/55 38/38 70/70 32/32 70/70 46/462 3/4” М25Х1,5 44/44 28/28 22/22 14/14 68/68 48/51 39/39 30/30 60/60 28/28 60/60 38/383 1” М32Х1,5 34/34 22/22 17/17 12/12 50/50 33/33 30/30 21/21 39/39 18/18 39/39 25/254 1 1/4” М40Х1,5 24/24 15/15 10/11 7/7 36/36 24/25 20/20 15/15 33/33 15/15 33/33 21/215 1 1/2” М50Х1,5 20/20 14/12 8/8 5/5 26/26 20/20 16/16 11/11 21/21 10/10 21/21 14/146 2” М63Х1,5 14/14 9/8 6/6 4/4 21/21 15/15 14/14 10/10 18/18 8/8 18/18 12/127 2 1/2” М75Х1,5 10/10 6/6 5/5 3/3 14/14 10/10 8/8 6/6 13/13 6/6 13/13 8/88 3” М90Х1,5 6/6 4/4 4/4 3/3 10/10 6/6 5/5 4/4 7/7 3/3 7/7 4/4
Terminals Type of terminal RN.1 CBD.2 CBD.4 CBD.6 CBD.10 CBD.16 CBD.35 CBD.50 CBD.70 CBD.120 CBD.185 CBD.240Cable conductor cross-sec., mm 0,2–2,5 0,5–4 0,5–6 0,5–10 0,5–16 0,5–25 0,5–50 1–70 1–95 6–150 6–240 70–240
Rated current, A 17,5 24 32 41 57 76 125 150 192 269 353 400
Maximum number of terminals installed into SHORV enclosures
Enclosure markingNumber of terminals/wire cross-section, mm
2,5 4 6 10 16 35 50 70SHORV281811 31 26 21 17 14 10 9 3SHORV302021 56 48 24 20 16 10 9 6SHORV422221 100 84 68 54 23 17 15 13SHORV362827
117 99 78 44 35 26 20 16SHORV362821SHORV423229
150 126 102 81 54 40 34 20SHORV423222SHORV464621 245 208 168 136 112 54 48 32SHORV573931
300 252 204 120 99 54 48 42SHORV573926SHORV654533
344 292 236 188 156 87 78 50SHORV654526SHORV725235
424 356 288 212 176 99 90 56SHORV725224SHORV896745
508 432 348 280 232 120 105 93SHORV896735
SHORV1045839 435 370 300 240 138 104 92 80SHORV1077740 604 511 416 332 276 208 184 115
FORMATION OF MARKING
SHORV X (X X – X X) – X X (X) – X X (X) / X – TU 3400-005-72453807-07
Product nameSize codeNumber of terminalsType of terminalNumber of cable glandsCable gland typeSide of cable gland locationOptions, accessories and versions
Example of order: SHORV362821 (40C2 – 10C16) – 5KNV1N(B) – 2KNV4N(D) – TU 3400-005-72453807-07
If you find it difficult to select box size in accordance with required characteristics, just leave Xs instead of digits after box name:Example of order:: SHORV Х (40C2 - 10C16) – 5KNV1N(B) – 2KNV4N(D)- TU 3400-005-72453807-07.
SHORV-N CCFE/SS
30
Stai
nles
s st
eel
term
inal
bo
xes
• Shape of explosion-proof boxes ensures easy access for installation of equipment inside the enclosure, SHORV-N boxes have external flange.
• Seamless solid cast enclosure.• Molded enclosure is not susceptible to “weld seam corrosion” which oc-
curs in products welded from several parts. This type of corrosion damages weld seams and is characterized by falling out of metal grains (sensitization) which makes the product less reliable in general. Seamless solid cast construc-tion allows to extend service life for more than 30 years.
• Explosion-proof SHORV-N boxes are produced in 2 versions: standard ver-sion with IP66 degree of protection and version with IP67 degree of protection
• SHORV-N series boxes with IP67 degree of protection are the result of an upgrade of a standard box, i.e. a rim in the cover’s flange, into which a round-section sealant is being put.
• Technology of molding allows to produce an enclosure of increased non-deforming geometrical accuracy and achieve parameters required for ex-plosion protection class IIC (except acetylene atmospheres).
MARKING
1Ex d IIС T6...T4 Gb X
1Ex d [ia] IIC T6...T4 Gb X
1Ex d [ib] IIC T6...T4 Gb X
1Ex d IIB+H2 T6...T4 Gb
1Ex d [ia] IIB+H2 T6...T4 Gb
1Ex d [ib] IIB+H2 T6...T4 Gb
Ex tb IIIC T70°C...T135°C Db
MINING EQUIPMENT MARKING
PB Ex d I MbРН1, РН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004Maritime Register Type Approval Certificate No. 16.03662.315IECEx CCVE 16.0007U (for enclosure only)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666VTT 17 ATEX 047U (for enclosure only)
CODESGOST 14254-96 (IEC 529-89)GOST R IEC 60079-31-2010GOST 12.2.007.0-75GOST R IEC 60079-0-2011GOST IEC 60079-1-2011GOST 30852.10-2002 (IEC 60079-11:1999)GOST 30852.20-2002TR CU 012/2011GOST IEC 61241-1-1-2011Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST 24754-2013
TECHNICAL CHARACTERISTICS
Installation
Category I for firedamp and dust;Category II for gas subgroup IIA, IIB+H2, IIC (except for acetylene); zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Facilities under Russian Maritime Register of Shipping supervision
Maximum voltage, V
~1000, A250~/7200 (for SHORV-N64433) ~1140 / A250V (for mining explosion-proof version)
Maximum current, A
650; 1500 (for ~1000 V, A250 V)
Surface
Shot blasting (outside and inside)
Sealant
Silicone rubber (in cover groove) for IP67, silicone
Installation inside enclosure
4 racks for mounting panel installation
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6667
HOLOD
SHORV-N CCFE/SS
31
Stai
nles
s st
eel
term
inal
bo
xes
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Drain plug for condensate removal /DKUV
Breather plug for moisture removal /VKU
Marine version /MORE
Version for minimum operating temperature -75°C /HOLOD
Version for tropics with protection against bugs /TERMITY
Special version for nuclear facilities of nuclear power plants “Small leak” /MALAYA TECH
Earthquake-resistant version /MSK-64
Acceptance by customer /PRIEMKA
Nameplate with inscription as per customer’s specification /NADPIS «_»
Degree of protection IP67 /IP67
DESCRIPTION MARKING
Nameplates with light reflecting coating /SVP
Bolt with seal /PLOMBA
Device for connection of cable screens /EKRAN
Neutral bus bar /SHINA N
Internal ground bus bar /SHINA Z
Phase bus bar /SHINA PH
Terminal jumpers as per customer’s diagram /SCHEMA
Marking of terminals as per customer’s dia-gram /MARK
Aluminum alloy mounting plate /ALP
Internal thermal insulation /TEPLOISOLYATSIYA
Heating for automatic devices /OBOGREV
OVERALL AND MOUNTING DIMENSIONS
Dimensions of SHORV-N enclosures*
Dimension type of enclosure
Dimensions, mm
Mass, kgExternal Internal Standard fastening Fastening with brackets
A B C a b c S S1 d e f D E FSHORV-N281811 286 185 118 214 114 79,5 12,5 15,5 160 123,5 M8 160 171 11 17,9SHORV-N312120 308 208 197 240 140 153 11 15,5 230 130 M8 230 210 9 26,7SHORV-N432221 430 229 215 365 164 168 12,5 15,5 350 150 M10 350 230 11 43,7SHORV-N372920 370 289 208 305 224 161 12,5 15,5 290 210 М10 290 290 11 43,9SHORV-N372926 370 289 268 305 224 221 12,5 15,5 290 210 M10 290 290 11 52,3SHORV-N563823 568 387 237 495 315 184 15,5 15,5 360 236 М10 360 376 11 93,5SHORV-N563828 568 387 287 495 315 234 15,5 15,5 360 236 M10 360 376 11 103,1SHORV-N644433 641 441 339 565 364 273 20 16,5 400 280 M12 400 440 14 157,5
* It is possible to manufacture non-standard sizes of enclosure
Mounting panelAa
Bb
Dimensions of mounting panels for SHORV-N enclosures
Name Dimensions, mm Box type Material Mass, kgА В a bSHN2818Н 220 120 180 80 SHORV-N281811 stainless steel —SHN3121Н 220 120 180 80 SHORV-N312120 stainless steel —SHN3729Н 460 280 440 260 SHORV-N372920 stainless steel —SHN4322Н 340 140 300 100 SHORV-N432221 stainless steel —SHN3729Н 280 200 240 160 SHORV-N372926 stainless steel 0,435SHN5638Н 460 280 440 260 SHORV-N563823 stainless steel —SHN5638Н 460 280 440 260 SHORV-N563828 stainless steel 0,660SHN6444Н 540 340 500 300 SHORV-N644433 stainless steel 1,425
SHORV-N CCFE/SS
32
Stai
nles
s st
eel
term
inal
bo
xes
Maximum number of cable glands on sides of SHORV-N boxes
Dimension type of enclosure
Side A Side B
Cable gland thread type Cable gland thread type
1/2"20х1,5
3/4"25х1,5
1"32х1,5
1 1/4"40х1,5
1 1/2"50х1,5
2"63х1,5
2 1/2"75х1,5
3"90x1,5 4" 1/2"
20х1,53/4"
25х1,51"
32х1,51 1/4"40х1,5
1 1/2"50х1,5
2"63х1,5
2 1/2"75х1,5
3"90x1,5 4"
SHORV-N281811 4 4 3 3 — — — — — 3 2 2 1 — — — — —SHORV-N312120 12 8 7 6 3 2 2 1 1 8 5 4 3 2 1 1 1 —SHORV-N432221 21 18 12 10 7 5 3 3 2 9 8 5 4 3 2 1 1 1SHORV-N372920 15 12 8 6 5 3 2 2 1 12 9 6 5 3 2 2 1 1SHORV-N372926 24 18 13 11 7 6 4 2 1 16 11 9 6 5 4 2 1 1SHORV-N563823 28 24 17/15 12 10 7 4 3 3 18 15 10 8 6 4 2 2 1SHORV-N563828 43 35 22 18 15 10 7 4 3 28 20 14 12 8 6 4 2 1SHORV-N644433 55 45 32 23 18 14 9 7 — 36 28 18 14 12 8 6 4 —
Maximum number of cable glands on sides of SHORV-N boxes
Previous international name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
The Customs Union name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
CCFE-SS SHORV-NCCFE-1SS SHORV-N312120CCFE-2SS SHORV-N432221CCFE-3SS SHORV-N372926
CCFE-3BSS SHORV-N372920*CCFE-4SS SHORV-N433328*
CCFE-4BSS SHORV-N433321*CCFE-45SS SHORV-N563828
CCFE-45BSS SHORV-N563823*CCFE-5SS SHORV-N644433
CCFE-5BSS SHORV-N634325*CCFE-55SS SHORV-N715131*
CCFE-55BSS SHORV-N715121*CCFE-6SS SHORV-N866440*
CCFE-6BSS SHORV-N866430*CCFE-7SS SHORV-N1007035*
* boxes are manufactured upon request
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNE, KNVZ refer to p. 393
Order placement
33
Term
inal
bo
xes
Terminals Type of terminal RN.1 CBD.2 CBD.4 CBD.6 CBD.10 CBD.16 CBD.35 CBD.50 CBD.70 CBD.120 CBD.185 CBD.240
Cable conductor cross-sec., mm 0,2–2,5 0,5–4 0,5–6 0,5–10 0,5–16 0,5–25 0,5–50 1–70 1–95 6–150 6–240 70–240
Rated current, A 17,5 24 32 41 57 76 125 150 192 269 353 400
Maximum number of terminals installed into SHORV-N enclosures, pcs.
Enclosure markingNumber of terminals/wire cross-section, mm
2,5 4 6 10 16 35 50 70
SHORV-N281811 31 26 21 17 14 10 9 3SHORV-N312120 56 48 24 20 16 10 9 6SHORV-N432221 100 84 68 54 23 17 15 13SHORV-N372920 117 99 78 44 35 26 20 16SHORV-N372926 117 99 78 44 35 26 20 16SHORV-N563823 300 252 204 120 99 54 48 42SHORV-N563828 300 252 204 120 99 54 48 42SHORV-N644433 344 292 236 188 120 90 68 50
FORMATION OF MARKING
SHORV-N X (X X – X X) – X X (X) – X X (X) / X – TU 3400-005-72453807-07
Product nameSize codeNumber of terminals Type of terminalNumber of cable glandsCable gland typeSide of cable gland locationOptions, accessories and versions
Example of order: SHORV-N372926 (40C2-10C16)-5KNV1N(B)-2KNV4N(D) – TU 3400-005-72453807-07
If you find it difficult to select box size in accordance with required characteristics, just leave Xs instead of digits after box name:Example of order: SHORV Х (40C2 - 10C16) – 5KNV1N(B) – 2KNV4N(D) – TU 3400-005-72453807-07
SHORVA CCA
34
Alu
min
um
term
inal
bo
xes
• Enclosures ensure protection in explosive mixtures of Category IIC by means of threaded joint of enclosure and cover.
• 10 dimension types of enclosures (including enclosures with window).
• SHORVA enclosures are tested in conditions up to -60°C.• Over 25 years of flameproof joint service life.• High resistance of aluminum alloy SHORVA enclosures to hydrogen
sulfide exposure• Internal surface without coating ensures increased thermal
conductivity
MARKING
1Ex d IIC T6...T4 Gb
1Ex d [ia] IIC T6...T4 Gb
1Ex d [ib] IIC T6...T4 Gb
Ex tb IIIC T85°С...T135°С Db
1Ex d e mb IIC T6...T4 Gb
MINING EQUIPMENT MARKING
РВ Ex d I Mb X
РВ Ex d [ib] I Mb XРН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004Maritime Register Type Approval Certificate No. 16.03657.315IECEx CCVE 16.0008U (for enclosure only)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST R IEC 60079-0-2011GOST R IEC 60079-31-2010GOST 14254-96 (IEC 529-89)GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.10-2002 (IEC 60079-11:1999)GOST 30852.20-2002TR CU 012/2011GOST IEC 61241-1-1-2011GOST 24754-2013Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST 12.2.007.0-75
TECHNICAL CHARACTERISTICS
Installation
Category I for firedamp and dust;Category II for gas subgroup IIA, IIB, IIC; zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Facilities under Russian Maritime Register of Shipping supervision;Dangerous production facilities
Maximum voltage, V
~1000 / A250
Maximum current, A
400
Sealant
Silicone sealant
Installation inside enclosure
2 or 4 racks for mounting panel installation
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6667 68
SHORVA CCA
35
Alu
min
um
term
inal
bo
xes
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Drain plug for condensate removal /DKUV
Breather plug for moisture removal /VKU
Marine version /MORE
Version for tropics with protection against bugs /TERMITY
Special version for nuclear facilities of nuclear power plants “Small leak” /MALAYA TECH
Acceptance by customer /PRIEMKA
Nameplate with inscription as per customer’s specification /NADPIS «_»
Stainless steel mounting plate /NP
External surface coating as per customer’s specification /RAL (code)
Nameplates with light reflecting coating /SVP
Device for connection of cable screens /EKRAN
DESCRIPTION MARKING
Neutral bus bar /SHINA N
Internal ground bus bar /SHINA Z
Phase bus bar /SHINA PH
Terminal jumpers as per customer’s diagram /SCHEMA
Marking of terminals as per customer’s diagram /MARK
Aluminum alloy mounting plate /ALP
Internal thermal insulation /TEPLOISOLYATSIYA
Heating for automatic devices /OBOGREV
Anti-condensation coating /AP
Degree of protection IP68 /IP68
Radiator cooling system /RADIATOR
OVERALL AND MOUNTING DIMENSIONS
Dimensions of SHORVA enclosures*
Dimension type of enclosureDimensions, mm
Mass, kgExternal Internal FasteningA B C a b c Ød Ød1 s E F ØG
SHORVА121211 120 120 115 94 94 74 82 M95x2 13 100 145 10 1,9SHORVА151512 151 151 125 124 124 84 116 M130x2 13 126 174 11 2,8SHORVА171712 175 175 129,5 146 146 89 137 M150х2 14 150 195 11 3,6SHORVА232316 235 235 164 203 203 117 185 M200х2 14 196 267 14 7,4SHORVА272721 276.5 276.5 218 248 248 152 232 M250x3 14 236 316 14 11,4SHORVА424229 429,5 429,5 291 395,5 395,5 216 330 M390x4 16,5 390 480 14 35,6
If it is necessary to manufacture a large-sized enclosure, several enclosures may be used.
Maximum recommended number of cable glands on sides of SHORVA boxes
Enclosure sizeThread size
01 1 2 3 4 5 6 7 8Thread type, R as per GOST 6211, M as per GOST24705
R/M R/M R/M R/M R/M R/M R/M R/M R/MSHORVA121211 3/2 2/2 2/2 1/1 1/1 — — — —SHORVA151512 5/5 4/4 3/3 2/2 2/2 1/1 — — —SHORVА171712 6/6 5/5 3/3 2/2 2/2 2/2 1/1 — —SHORVА232316 8/8 8/8 7/8 4/4 3/3 2/2 2/2 2/2 —SHORVА272721 14/14 14/14 11/11 8/8 6/6 4/4 3/3 2/2 2/2SHORVА424229 22/22 22/22 18/18 11/12 10/10 8/8 5/5 3/3 3/3
Order placement
36
Alu
min
um
term
inal
bo
xes
Dimensions of mounting panels
NameDimensions, mm
Dimension type of enclosureA B a b
SА1212X 80 80 60 48 SHORVА121211SА1515X 100 100 80 60 SHORVА151512SА1717X 113 113 90 90 SHORVА171712SА2323X 150 150 130 130 SHORVА232316SА2727X 200 200 158 158 SHORVА272721SА4242X 315 315 230 230 SHORVА424229
* X — material code: A — aluminum, N — stainless steel.
Terminals Type of terminal RN.1 CBD.2 CBD.4 CBD.6 CBD.10 CBD.16 CBD.35 CBD.50 CBD.70 CBD.120 CBD.185 CBD.240
Cable conductor cross-sec., mm 0,2–2,5 0,5–4 0,5–6 0,5–10 0,5–16 0,5–25 0,5–50 1–70 1–95 6–150 6–240 70–240
Rated current, A 17,5 24 32 41 57 76 125 150 192 269 353 400
Maximum number of terminals installed in SHORVA enclosures, pcs.
Enclosure marking Number of terminals/wire cross-section, mm2,5 4 6 10 16 35 50 70
SHORVА121211 9 7 6 4 4 — — —SHORVА151512 15 12 10 8 6 5 4 —SHORVА171712 23 19 12 9 8 6 5 3SHORVА232316 43 37 29 20 18 8 7 6SHORVА272721 72 60 48 27 24 16 14 8SHORVА424229 144 124 75 60 48 30 28 20
FORMATION OF MARKING
SHORVA X (X X – X X) – X X (X) – X X (X) / X – TU 3400-005-72453807-07
Product nameSize codeNumber of terminals Type of terminalNumber of cable glandsCable gland typeSide of cable gland locationOptions, accessories and versions
Example of order: SHORVA171712 (40C2-10C16)-3KNV1N(B) – 2KNV4N(G) – TU 3400-005-72453807-07
If you find it difficult to select box size in accordance with required characteristics, just leave Xs instead of digits after box name:
Example: SHORVA Х (40C2 - 10C16) – 3KNV1N(B) – 2KNV4N(D) – TU 3400-005-72453807-07.
Table of names matching
Previous international name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
The Customs Union name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
ССА SHORVАCCA SHORVА121211
CCA-0 SHORVА151512CCA-01 SHORVА171712CCA-02 SHORVА232316CCA-03 SHORVА272721CCA-04 SHORVА424229
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNE, KNVZ refer to p. 393
Datasheet
37
Term
inal
bo
xes
GORELTEX DATASHEET FOR NON-TYPICAL EXPLOSION-PROOF SHORV (CCFE), SHORVA (CCA) TERMINAL BOXES Exd, RV
Installation zone Zone 1 RV Version RN Version Required type of explosion protection __________Group and subgroup of air and gas
mixture I IIB+H2 IICX IIC IIIC IP degree IP66 (by default)
Temperature class Т4 Т5 T6Operating
temperature Tamb from_____ to _____
Dimensional limitations, mm (if any) _______Х_______ Х_______length height depth
Arrangement of terminal blocks (non-mandatory field)
Terminals
Cross-section, mm² Quantity, pcs. Type of terminal (screw by default)
Ground PE
Cable glands
Designation of enclosure sides Quantity of cable
glands Location side Outer cable sheath diameter, mm
Inner cable sheath diameter, mm (for
armored cable only) or diameter of cable in metal hose, mm
Cable gland type Cable type
Accessories and versions (non-man-
datory field)
Material of enclosureCorrosion-resistant
aluminum-silicon alloyStainless chrome-
nickel steel
SHORVА SHORV SHORV-N
Anti-condensation coating /AP NO
External surface coating as per customer’s specification /RAL (code) RAL RAL NO
Version for minimum operating temperature -75°C /HOLOD NO
Bolt with seal /PLOMBA NO
Captive bolts for cover fastening /NBK NO
Alignment pin (for large-sized enclosures) /SHTIFT NO
Drain plug for condensate removal /DKUV Acceptance by customer /PRIEMKA
Breather plug for moisture removal /VKUV Nameplate with inscription as per customer’s specification /NADPIS «_»
Marine version /MORE Terminal jumpers as per customer’s diagram /SCHEMA
Version for tropics with protection against bugs /TERMITY Nameplates with light reflecting coating /SVP
Special version for nuclear facilities of nuclear power plants “Small leak” /MALAYA TECH Device for connection of cable screens /EKRAN
Earthquake-resistant version /MSK-64 Internal ground bus bar /SHINA Z
Neutral bus bar /SHINA N Stainless steel mounting panel /NP
Phase bus bar /SHINA PH Aluminum alloy mounting plate /ALP
ТHeating for automatic devices /OBOGREV Marking of terminals as per customer’s diagram /MARK
Internal thermal insulation /TEPLOISOLYATSIYA
Radiator cooling system /RADIATOR
Quantity of boxes, pcs pieces Climatic category by default – NF1
Contact detailsCompany: Tel./fax:Postal address:Contact person: E-mail:
“ZAVOD GORELTEX” Co. Ltd.
B
CА
D
А
B
C
D AUTOMATIC DEVICES
SIDE OF LOCATION __
KKVA S
38
Alu
min
um
term
inal
bo
xes
• High degree of protection IP66/67.• KKVA boxes may be equipped with terminals for wires with cross-
section up to 35 mm2.• 1-4 holes in the enclosure.• Various options of fastening to vertical and horizontal surfaces;
KKVA-TSG series boxes allow installation on the walls and ceiling at right angle.
• Thread in the holes of the box by default N (NPT) taper inch. Other types of thread upon request.
MARKING
1Ex d IIC T6..T4 Gb
0Ex ia IIC T6..T4 Ga
1Ex s IIC T6..T4 Gb
1Ex e II T6..T4 Gb
Ex tb IIIC T85°С...T135°С Db
Ex ia IIIC T85°С..T135°С Da
MINING EQUIPMENT MARKING
РВ Ex d I Mb XРН2
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244РОСС RU.EX01.B00004VTT 17 ATEX 047U (for enclosure only)TC RU C -RU.МЛ02.B.00626Maritime Register upon request (check cost and terms of Type Approval Certificate issuance with manager)IECEx CCVE 16.0008U (for enclosure only)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST 14254-96 (IEC 529-89)GOST R IEC 60079-0-2011GOST R IEC 60079-31-2010GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.8-2002GOST 22782.3-77GOST 30852.10-2002 (IEC 60079-11:1999)GOST IEC 61241-1-1-2011GOST 24754-2013TR CU 012/2011, ТР ТС 004/2011Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST 12.2.007.0-75,GOST 30852.20-2002
TECHNICAL CHARACTERISTICS
Installation
Category I for firedamp and dust;Category II for gas subgroup IIA, IIB, IIC; zones 0, 1, 2;Category III for dust, explosive dust atmospheres containing flying parti-cles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Non-hazardous areas of ground facilities and open sites;Dangerous production facilities
Maximum voltage, V
750
Maximum current, A
175
Sealant
Silicone sealant
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6667
KKVA S
39
Alu
min
um
term
inal
bo
xes
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Stainless steel version /N
Anti-condensation coating /AP
Stainless steel cover chain /TSEPOCHKA
Polymer epoxy coating /RAL (code)
Non-explosion-proof version (fireproof) /PROM
KKVA explosion-proof junction and conduit boxes
Type Thread size DrawingCover
diameter, mm
H A1 B C X Mass, kg.
KKVA-К90N1 4x1/2”
F
HA1
A1
90 75,5 106 —0,6
KKVA-К90N2 4x3/4” 0,6KKVA-К90N3 4x1” 0,5
KKVA-К144N1 4x1/2”
144 115 175 —
2,3KKVA-К144N2 4x3/4” 2,2KKVA-К144N3 4x1” 2,1KKVA-К144N4 4x1/2” 2KKVA-К144N5 4x3/4” 1,9
KKVA-К144N6 4x1” 1,7
KKVA-КC90N1 4x1/2”
A1
BX
H
F
Ø7
90 75,5 106 130 — 1090,7
KKVA-КC90N2 4x3/4” 0,7KKVA-КC90N3 4x1” 0,6
KKVA-КS144N1 4x1/2”
144 119 175 190 — 170
2,5
KKVA-КS144N2 4x3/4” 2,3KKVA-КS144N3 4x1” 2,2KKVA-КS144N4 4x 1 1/4” 2,1KKVA-КS144N5 4x 1 1/2” 2
KKVA-КS144N6 4x 2” 1,9
KKVA-TSG 90N1 3x1/2”
C
A1 H
F
XB
6Ø
90 75,5 106 125 121 1110,7
KKVA-TSG 90N2 3x3/4” 0,7KKVA-TSG 90N3 3x1” 0,6
KKVA-TSG 144N1 3x1/2”
144 120 175 160 186 130
3,4KKVA-TSG 144N2 3x3/4” 3,3KKVA-TSG 144N3 3x1” 3,2KKVA-TSG 144N4 3x 1 1/4” 3,1KKVA-TSG 144N5 3x 1 1/2” 3
KKVA-TSG 144N6 3x 2” 2,9
*Maximum number of holes – 4.Main characteristics of installed terminals
Type of terminals Nominal cross-section, mm2Cable cores
cross-section, mm2
Rated current, A Maximum voltage, VDimensions, mm
А В С
CBD.2 2,5 0,5–4 24 750 47 40,5 5,5CBD.4 4 0,5–6 32 750 52 44 6,5CBD.6 6 0,5–10 41 750 52 44 8
CBD.10 10 0,5–16 57 750 55 44 10CBD.16 16 0,5–25 76 750 57 47 12CBD.35 35 0,5–35 125 750 60 52 16
RР.4 4 0,2–6 32 275 35 31 6RN1 1,5 0,2–2,5 17,5 500 32 27 4,2RN2 2,5 0,2–4 24 400 32 27 5
Maximum permitted number of installed small-sized RN, RP terminals
Nominal wire cross-section, mm2 Number of terminals1,5 2,5 4
KKVA-К90 7 6 5KKVA-К144 18 15 12
Maximum permitted number of installed CBD/CBC terminals
Nominal wire cross-section, mm2 Number of terminals2,5 4 6 10 16 35
KKVA-К144 14/15 11/12 9/9 7/7 6/6 3/4FORMATION OF MARKING
KKVA S
40
Alu
min
um
term
inal
bo
xes
KKVA – ХХХ(XX - XX) - Х(Х)/Х – TU 3400-005-72453807-07Product nameLocation of holesDimension type codeSize and code of threadNumber of terminals Type of terminalCable gland typeSide of cable gland locationOptions, accessories and versions
A
B
C
D
Table of names matching
Previous international name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
The Customs Union name “ZAVOD GORELTEX” Co. Ltd.TU 3400-005-72453807-07
S KKVASX-16.1 KKVA-К90N1SX-26.1 KKVA-К90N2 SX-36.1 KKVA-К90N3SX-29.1 KKVA-К144N2SX-39.1 KKVA-К144N3SX-59.1 KKVA-К144N5
SFX-16.1 KKVA-KS90N1SFX-26.1 KKVA-KS90N2 SFX-36.1 KKVA-KS90N3SFX-29.1 KKVA-KS144N2SFX-39.1 KKVA-KS144N3SFX-59.1 KKVA-KS144N5SSC-16.1 KKVA-TSG90N1SSC-26.1 KKVA-TSG90N2 SSC-36.1 KKVA-TSG90N3SSC-29.1 KKVA-TSG144N2SSC-39.1 KKVA-TSG144N3SSC-59.1 KKVA-TSG144N5
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNE, KNVZ refer to p. 393
86
PKIVA, PKIV CSE, CCFE-01, CSC-G
Loca
l con
trol
st
atio
ns,
sign
alin
g de
vice
s
• Flexible system of modulation on the base of one-, two-, three- or multi-button enclosures.
• Ultra-high mechanical and corrosion resistance of explosion-proof pins of control elements.
• Contact modules and light sources can easily be replaced.
• High resistance to hydrogen sulfide exposure. • Over 25 years of flameproof joint service life.
MARKINGfor PKIVA (CSE, CSC-G):
1Ex d IIC T6...T5 Gb
0Ex ia IIC T6...T5 Ga
Ex tb IIIC T85°С...T100°С Db
for PKIV (CSE + CSE, CCFE):
1Ex d IIС T6...T4 Gb X
1Ex d [ia] IIС T6...T4 Gb X
1Ex d IIB+H2 T6...T4 Gb
1Ex d [ia] IIB+H2 T6...T4 Gb
Ex tb IIIC T85°С...100°С Db
Ex tb IIIC T70°С...T135°С DbMINING EQUIPMENT MARKING
РВ Ex d I Mb
PO Ex ia I Ma (for PKIVA)
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244VTT 17 ATEX 047U (for enclosure only)RU.OC BCCT 048-08.2017Maritime Register Type Approval Certificate No. 17.12694.120IECEx CCVE 16.0007U (for enclosure only)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST 12.2.007.0-75GOST R IEC 60079-0-2011GOST R IEC 60079-31-2010GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST 30852.10-2002 (IEC 60079-11:1999)GOST 30852.20-2002TR CU 012/2011GOST IEC 61241-1-1-2011Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST IEC 60079-1-2011
TECHNICAL CHARACTERISTICS
Installation
Category I for firedamp and dust; Category II for gas subgroup IIA, IIB+H2, IIC (except for acetylene), IIC; zones 0, 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Underground mines non-hazardous with gas (methane) and coal dust;Facilities under Russian Maritime Register of Shipping supervision;Dangerous production facilities
Maximum voltage, V
~240 / ~380 / A110
Maximum current, A
~16 / ~10 / A5
Thread on connecting holes
Taper pipe Rc GOST 6211 for PKIV, N, NPT for PKIVA (other type and size of thread, second hole upon request)
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
IP 6667
87
PKIVA, PKIV CSE, CCFE-01, CSC-G
Loca
l con
trol
st
atio
ns,
sign
alin
g de
vice
s
DESCRIPTION MARKING
Combined color of external surface (yel-low/black) external surface coating
/KRYSHKA RAL 1003/KORPUS RAL 9004
Marine version /MORE
Version for tropics with protection against bugs /TERMITY
Anti-condensation coating /AP
Protective canopy /KOZYREK
Special version for nuclear facilities of nu-clear power plants /MALAYA TECH
Drain plug for condensate removal /DKU
Breather plug for moisture removal /VKU
Hinge for cover fixation (for SHORV281811, for other sizes of SHORV boxes hinges are installed by de-fault)
/PETLYA
Captive bolts for cover fastening /NBK
External surface coating as per customer’s specification /RAL (code)
Version for minimum operating tempera-ture -75°C /HOLOD
Moving suspension mounting /PODVES
Handle’s fastening /RUCHKI
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Lamp supply voltage
/6DC/6AC
/12DC/12AC/24DC/24AC/36DC/36AC/48DC/48AC
/110DC/110AC/220AC/380AC
Degree of protection IP67 /IP67
Nameplate with inscription as per customer’s specification /NADPIS «_»
Nameplates with light reflecting coating /SVP
Earthquake-resistant version /MSK-64
Yellow external surface coating /RAL 1003
Black external surface coating /RAL 9004
OVERALL AND MOUNTING DIMENSIONS
PKIVA101008 with one element
105
113
130
109
1057
Ø3/4'
Ø3/4'
PKIVA161008 with two elements PKIVA211108 with three elements
121
105
103
109
160
81,3
8
Ø3/4'
Ø3/4'
121
116
103
109
Ø3/4'
Ø3/4'
200
121,
38
LGV, KGV is a conventional designation of function button and signal lamp; types of elements are specified when making an order.
184
PPG25 CSC
Rot
ary
switc
hes,
lim
it sw
itche
s
• High resistance to hydrogen sulfide exposure.• Service life of flameproof joints of PPG series Exd explosion-proof
enclosures is more than 25 years.• Sunk position of an operating handle on PPG enclosures protects
against accidental switching in case of dropping of different objects or ice from the racks, and its large size allows to work in gloves (which is important for outdoor operation at low temperatures).
• Overheating and further malfunctioning of electromechanical components are impossible as specially selected switching appara-tuses with insulating materials of higher quality in comparison to the ones of general industrial type are used as internal components in the enclosures.
MARKING
1Ex d IIC T6...T5 Gb
Ex tb IIIC T85°С...T100°С Db
CERTIFICATES AND PERMITSGOST R ISO 9001-2015 (ISO 9001:2015)ТС RU С-RU.AA87.В.00244RU.OC BCCT 048-08.2017Maritime Register Type Approval Certificate No. 17.12694.120 (SHORV-SC)IECEx CCVE 16.0007U (for enclosure only)TU 3400-005-72453807-07GAZPROM OJSC No. Г000.RU.1131.H00666
CODESGOST 14254-96 (IEC 529-89)GOST R IEC 60079-0-2011GOST 30852.0-2002 (IEC 60079-0:1998)GOST 30852.1-2002 (IEC 60079-1:1998)GOST IEC 61241-1-1-2011TR CU 012/2011Electrical Installation Code Ch. 7.3, Ch. 7.4OD 5.2-093-2004GOST R IEC 60079-31-2010
TECHNICAL CHARACTERISTICS
Installation
Category II for gas subgroup IIA, IIB, IIC, zones 1, 2;Category III for dust, explosive dust atmospheres containing flying particles, conductive and non-conductive dust;Facilities under Russian Maritime Register of Shipping supervision;Dangerous production facilities
Maximum voltage, V
~690, A250
Mass, kg
2,5
Rated current, A
up to 25
Thread on connecting holes
Taper pipe NPT 1”
Mechanical wear resistance
10 mil. switching cycles (assembly on the base of Schneider Electric components)
Climatic category
NF1 (upon request NF2, NF3, NF4, NF5, F1, F2, F3, F5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.13**, W5)
66IP
185
PPG25 CSC
Rot
ary
switc
hes,
lim
it sw
itche
s
OPTIONS, ACCESSORIES AND VERSIONS
DESCRIPTION MARKING
Option of locking handles of rotary switches /ZAMOK
Marine version /MORE
Earthquake-resistant version /MSK-64
OVERALL AND MOUNTING DIMENSIONSROTARY SWITCHES TYPE PPG-25
Type Rated current, A Closing diagram Number of
poles Description
PPG-1I25 25
ºº
1 3
º º2 4
0
1
1 Two-position switch with zero position, (0-1)
PPG-2I25 25
ºº
1 3
º º2 4
0
1
2 Two-position switch with zero position, (0-1)
PPG-3I25 25
ºº
1 3
º º2 4
0
1
ºº
5 7
º º6 8
3 Two-position switch, (0-1)
PPG-4I25 25
ºº
1 3
º º2 4
0
1
ºº
5 7
º º6 8
4 Two-position switch with zero position, (0-1)
PPG-1C25 25
ºº
1 3
º º2 4
0
1
1 Three-position switch with zero position, (0-1-2)
186
PPG25 CSC
Rot
ary
switc
hes,
lim
it sw
itche
s
Type Rated current, A Closing diagram Number of
poles Description
PPG-2C25 25
ºº
1 3
º º2 4
1
0
ºº
5 7
º º6 8
2 Three-position switch with zero position, (0-1-2)
PPG-3C25 25
ºº
1 3
º º2 4
1
0
ºº
5 7
º º6 8
ºº
9 11
º º10 12
2
3 Three-position switch with zero position, (0-1-2)
PPG-1Z25 25
ºº
1 3
º º2 4
1
2
1 Two-position switch without zero position (1-2)
PPG-2Z25 25
ºº
1 3
º º2 4
1
2
ºº
5 7
º º6 8
2 Two-position switch without zero position (1-2)
PPG-3Z25 25
ºº
1 3
º º2 4
1
2
ºº
5 7
º º6 8
ºº
9 11
º º10 12
3 Two-position switch without zero position (1-2)
PPG-1V25 25
ºº
1 3
º º2 4
L1–L2
ºº
5 7
º º6 8
L2–L3
L3–L1
3 Three-position switch for voltmeter, without zero position, turn angle 45°
PPG-2V25 25
ºº
1 3
º º2 4
0
1
ºº
5 7
º º6 8
ºº
9 11
º º10 12
2
3
0
3 Four-position switch for voltmeter, with zero position, turn angle 30°, 3 linear voltages
187
PPG25 CSC
Rot
ary
switc
hes,
lim
it sw
itche
s
Type Rated current, A Closing diagram Number of
poles Description
PPG-3V25 25
ºº
1 4
º º2 3
L1–L2
ºº
5 8
º º6 7
L2–L3
L3–L1
0
4
1
3
7
6
V
L1
L2
L3
3 Four-position switch for voltmeter, with zero position, turn angle 45°
PPG-4V25 25
ºº
1 3
º º2 4
L1–L2
ºº
5 7
º º6 8
L2–L3
L3–L1
03 Seven-position switch for voltmeter, without
zero position, turn angle 30°
PPG-5V25 25
ºº
1 3
º º2 4
L1–L2
ºº
5 7
º º6 8
L2–L3
L3–L1
0
ºº
9 11
º º10 12
L1–N
L2–N
L3–N
3 Seven-position switch for voltmeter, with zero position, turn angle 45°
PPG-6V25 25
ºº
1 3
º º2 4
L1–L2
ºº
5 7
º º6 8
L2–L3
L3–L1
ºº
9 11
º º10 12
L1–N
L2–N
L3–N
3 Four-position switch for voltmeter, with zero position, turn angle 30°, 3 phase voltages
188
PPG25 CSC
Rot
ary
switc
hes,
lim
it sw
itche
s
Type Rated current, A Closing diagram Number of
poles Description
PPG-1A25 25
ºº
1 4
º º2 3
L1–N
ºº
5 8
º º6 7
L2–N
L3–N
0
4
8
3
2
6V
L1
L2
L3
N 7
1 Switch for ammeter, for 3 transformer circuits with zero position, turn angle 45°
FORMATION OF MARKING
PPG – X X – X / X – TU 3400-005-72453807-07
Product nameDiagram typeCurrent, A: 25Number, dimension types of cable glands (max. 2 pcs.)Options, accessories and versions
Example of order: PPG–3I25–KOV4–TU 3400-005-72453807-07.
RECOMMENDED CABLE GLANDS FOR PPG 25A, 63A, 80A:
KNV3NNK/R — cable gland for non-armored cable, diameter of crimped cable 12-25 mm, nickel-plated brass.
KNVM3N-25NK/R — cable gland for non-armored cable in metal hoses, diameter of crimped cable 12-22 mm, inside diameter of metal hose 25 mm, nickel-plated brass.
KNVTV3NGNK/R — cable gland for non-armored cable in hoses, pipe conduit, metal hoses; internal thread for external connection pipe cylindrical GOST 6357-81 1" G, diameter of crimped cable 12-25 mm, nickel-plated brass.
KNVM3N-32NK/R — cable gland for non-armored cable in metal hoses, diameter of crimped cable 12-22 mm, inside diameter of metal hose 32 mm, nickel-plated brass.
Recommended cable glands KNV, KOV, KNVTN, KNVTV, KNVM, KNVZ refer to p.393