Regenerative Principle
Rotation
Out
In Air Flow
The impeller blades passing the inlet port draw air or other gases into the blower The impeller blades then by centrifigal action accelerate the air outward and forward Here the ldquoregenerativerdquo principle takes effect as the air is turned back by the annular shaped hous-ing to the base of the following blades where it is again hurled outward Each ldquoregenerationrdquo imparts more pressure to the air When the air reaches the stripper section at the outlet (the stripper is the part of the blower located between the inlet and the outlet in which the annulus is reduced in size to fit closely to the sides and tips of the impeller blades) the air is ldquostrippedrdquo from the impeller and diverted out of the blower The pressures or vacuums generated by each spinning non-contacting oil-free impeller are equal to those obtained by many larger multi-stage or positive displacement blowers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Table of Contents
A Nine Major Blower Application Areas B Product Dimensional Listing C Industrial Chemical Processing Blowers
DR P15 C57 400 600 HP Regenerative Blower
DR S15 C59 400 HP High Pressure Regenerative Blower
DR 068 C1125 HP Regenerative Blower
D Environmental Chemical Processing Blowers EN 101 amp CP 101 D1
DR 083 C3 5 HP Sealed Regenerative wExplosion-Proof Motor
125 HP Regenerative Blower EN 303 amp CP 303 D3
DR 101 amp CP 101 C5 5 HP Sealed Regenerative wExplosion-Proof motor
33 HP Regenerative Blower EN 404 amp CP 404 D5
DR 202 amp CP 202 C7 10 HP Sealed Regenerative wExplosion-Proof Motor
33 HP Regenerative Blower EN 454 amp CP 454 D7
DR 303 amp CP 303 C9 15 HP Sealed Regenerative wExplosion-Proof Motor
33 HP Regenerative Blower EN 505 amp CP 505 D9 DR 353 amp CP 353 C11 20 25 HP Sealed Regenerative wExplosion-Proof Motor 75 HP Regenerative Blower EN 513 amp CP 513 D11 DR 404 amp CP 404 C13 15 HP Sealed Regenerative wExplosion-Proof Motor 10 HP Regenerative Blower EN 523 amp CP 523 D13 DR 454 amp CP 454 C15 30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
15 HP Regenerative Blower EN 6 amp CP 6 D15 DR 505 amp CP 505 C17 50 HP Sealed Regenerative wExplosion-Proof Motor
20 30 HP Regenerative Blower EN amp CP 633 D17 DR 513 amp CP 513 C19 75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
15 HP Regenerative Blower EN 656 amp CP 656 D19 DR 523 amp CP 523 C21 30 HP Sealed Regenerative wExplosion-Proof Motor
3 HP High Pressure Regenerative Blower EN 757 Single-Phase and CP Options D21 DR 555 amp CP 555 C23 Sealed Regenerative Blower wExplosion-proof Motor
30 40 HP Regenerative Blower EN 757 amp CP 757 D23 DR 6 amp CP 6 C25 30 50 HP Sealed Regenerative wExplosion-Proof Motor
30 50 HP Regenerative Blower EN 808 Single-Phase and CP Options D25 DR 633 amp CP 633 C27 Sealed Regenerative Blower wExplosion-proof Motor
30 40 50 HP Regenerative Blower EN 808 amp CP 808 Three-Phase D27 Sealed Regenerative Blower wExplosion-proof MotorDR 656 amp CP 656
C29 30 40 50 HP Regenerative Blower EN 833 amp CP 833 D29
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor DR 757 amp CP 757 C31 40 50 HP Regenerative Blower EN 858 amp CP 858 D31
75 100 HP Sealed Regenerative wExplosion-Proof Motor DR S7 C33 75 HP High Pressure Regenerative Blower EN 909 amp CP 909 D33
100 150 HP Sealed Regenerative wExplosion-Proof Motor DR 808 amp CP 808 C35 50 75 HP Regenerative Blower EN 979 amp CP 979 D35
200 HP Sealed Regenerative wExplosion-Proof Motor DR 833 amp CP 833 C37 75 100 HP Regenerative Blower EN 14 amp CP 14 D37
200 300 HP Sealed Regenerative wExplosion-Proof Motor DR 858 amp CP 858 C39 75 100 HP Regenerative Blower
DR P9 C41 E Remote Drive (Motorless) Blowers MF573RD E1
150 200 HP Regenerative Blower SL2RD E2 DR S9 C43 DRENCP 404RD E3 150 200 HP High Pressure Regenerative Blower DRENCP 505RD E4 DR 909 amp CP 909 C45 DRENCP 513RD E5 100 150 HP Regenerative Blower DRENCP 523RD E6 DR 979 amp CP 979 C47 DRENCP 6RD E7 150 200 HP Regenerative Blower DRENCP 656RD E8 DR 1233 amp CP 1233 C49 DRENCP 757RD E9 200 HP High Pressure Regenerative Blower DRENCP 858RD E10 DR P13 C51 DRENCP 909RD E11 200 300 HP Regenerative Blower DRENCP 979RD E12 DR S13 C53 DRENCP 1233RD E13 200 300 HP High Pressure Regenerative Blower DRENCP 14RD E14 DR 14 amp CP 14 C55 200 250 300HP Regenerative Blower
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Table of Contents
F Application Specific Blowers Minispiral F1 Insrument Grade Regenerative Blower
Minispiral MDC F3 Variable Flow Regenerative Blower
Minispiral 1224V HDC F5 Variable Flow Regenerative Blower
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy F7 Variable Flow Regenerative Blower
SPIRAL Simplex SL2 F9 Insrument Grade Regenerative Blower
SPIRAL Duplex SL4 F11 Insrument Grade Regenerative Blower
SPIRAL Duplex SL5 F13 Insrument Grade Regenerative Blower
Nautilair F15 DR 404454505513656 F17 Spa Blowers
DR 10RDNTSS10RDNTHS 10RDNT F19 Remote Drive (Motorless) Blowers
MD 101 Magnetic-Drive F21 Regenerative Blower
GVR313 F23 Regenerative Blower
G Accessories Filtration - Inlet Filter (Single Connection) G1 Filtration - Inline Filter (Dual Connection) G2 Filtration - Filter Silencers (Single Connection) G3 Filtration - Filter Element G4 Filtration - Moisture Separator G5 Measurement - Air Flow Meter G7 Measurement - Digital Flowmeter G9 Noise Reduction - Sound Attenuating Enclosure G10 Noise Reduction - InletOutlet Muffler (Single Connection) G11 Noise Reduction - Inline Muffler (Dual Connection) G12 Protection - Relief Valve - Mechanical G13 Protection - Pressure Regulating Diaphram Valve G14 Protection - Gauges G15 System - Variable Frequency Drive G16 System - Air Knives G17 System - 5 Way 3 Port 2 Position Diverter Valve G19 System - Air Flow Switch G21 Pressure amp Vacuum Arrangements G22 H Motor Blower Options I Application Engineering Basics
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 1 Air-Assisted Breathing
Your own imagination and knowledge are probably the best source of in-plant and on-site applications for ROTRON regenerative blowers This guide will help to pinpoint and stimulate your consideration of the many alternative sources we provide to replace costly and maintenance intensive suction and pressure units and systems The nine major application groups are listed and a cross reference of the most common applications by industry will help you identify both identical and similar applications in your industrial operations
Nose
Part
Blower
Blower
Blower
Blower
Blower
Block
Box
BlowerWork Table
Work
Work
Plenum
PneumaticSuction Cups
Mouth
Flotation Tables
Air Slides Air Tables Turning amp Forming Bars
Air Film SupportAir BagsWeb
General Parts Pick-Up General Parts Hold-Down
Vacuum Manipulator Flotation Tables
Throat
ManufacturingPARP Respiration
MiningPARP Respiration
Application 2 Air-Assisted Inflation or SupportMaterial HandlingAir SlidesAir TablesCarbon Black Car Unloading
Paper ProcessingFlotation TablesForming BarSheet FlutteringTurn Bars
TextileGarment Flotation Tables
Water Pollution ControlPollution ContainmentWaterway Management
Application 3 Air-Assisted Vacuum Pick-Up or Hold-DownManufacturingBag Filling EquipmentCutting TablesPackaging EquipmentVacuum ManipulatorsCorrugated and Paperboard BoxesFlexible Packaging - Paper Plastic Aluminum Foil Textile Packaging and Steel StrappingRigid PackagingBeverage ContainersCosmetic and Toiletry ContainersBlister PacksPharmaceutical PackagingFood PackagingSterile Medical Device PackagingLabelsPressure Sensitive Tape
Paper or Plastics HandlingCutting TablesDiaper Making EquipmentPrinting Presses
TextileGarment Cutting TablesYarn Guiding and TensioningYarn AspirationCarboard Case Erector
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 4 Air amp Gas Sampling Boosting or Circulating
Fluid Bed Regeneration Transmissometer Lens Purging
Natural Gas Boost Air amp Gas Sampling
Combustion Air Boost
Pressurized Cabinet Vacuum Pull-Through Cabinet
Soil Vapor Extraction ampLandll Gas Recovery Vent Header O-Gassing
Fume amp Smoke Removal Digester Gas Collection
Air Pollution ControlAir SamplingAir Stream Release MonitoringFire Prevention Air SamplingFlue Gas Sampling
FoundryCombustion Air Boost
InstrumentationGlove Box PressurizingIncubator Air CirculationWeather Measurement Sampling
ManufacturingCombustion Air BoostNatural Gas BoostOil Demisting
PharmaceuticalClean Room Air CirculationOxygen Generator
Plastics HandlingDesiccant Dryer Bed Regeneration
Application 5 Electronic CoolingInstrumentationEngineMotor CoolingFilm Development System CoolingLamp Bank CoolingSmall Enclosure Cooling
Application 6 Gas Vapor amp Fume Recovery Venting amp TreatmentPharmaceuticalSterilization Gas (ETO) Recovery
ReneriesCentrifuge Venting
Water Pollution ControlDigester Gas Collection
AgriculturalMethane Gas RecoveryChemical ProcessingVent Header O-Gassing
EnvironmentalGasoline Vapor RecoveryLagoon Gas RecoveryLandll Gas RecoveryRadon Gas CollectionSoil Vapor Extraction
FoundryLost Foam O-Gassing
Manufacturing - Plant ServicesCabinet Fume VentingEnvironmental Test Chamber VentingLaser Smoke RemovalWeld Smoke Removal
Natural Gas
Blower
Blower
Blower
Blower
BlowerFilter
Blower
Blower Flame
Digester
Scrubber ChemicalTank
Treatment System
Electronics
Gas
CombustionChamber
BlowerBlower Blower
Light Beam
Lens
Stack
Lens
Natural GasFurnace
Minispiral
Instrument
Blower
Electronics
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 7 Solid Material Transporting Separation amp CollectionFoundrySand Reclamation
Manufacturing - Waste ControlChip Dust amp Particle RemovalLiquid amp Solvent RemovalPaper Plastic Film amp Textile (Trim) Removal
Material HandlingAir SlidesBlast CleaningDilute Phase ConveyingPneumatic Tube
PackagingBag Filling
Application 8 Parts Blow-Off amp Drying
Application 9 Solution amp Media Agitation amp AerationAquacultureAquarium Fish Farm Hatchery amp Pond Aeration
Groundwater Sparging
ManufacturingConcrete Fluid Bed AerationElectroplating Tank Agitation
Material HandlingFluidized Beds
RecreationCommercial Spa Aeration
Water ManagementBoat Dock amp Dam Face Deicing
Water Pollution ControlUV Tube AgitationWatewater Filter BackwashWastewater Treatment Tank Aeration
ManufacturingConveyor Belt Blow-OElectroplating Fume GuidingElectroplating Parts DryingElectroplating Solution Blow-BackFlat or Irregular Metal Parts DryingWire Drying
Aqueous Precision CleaningAutomotive Parts DryingSemiconductor Board Drying
Food ProcessingBatter Blow-OBottle amp Can DryingLabel DryingSalt Spice amp Flour Blow-O
Dilute Phase Pneumatic Conveying Pneumatic Tube
Paper Plastic Film amp Textile (Trim) Removal
General Parts Blow-O amp Drying Solution Blow-Back
Wastewater Treatment Tank Aeration Groundwater Sparging
Electroplating Tank Aeration Commercial Spa Aeration
Bin Pad amp Fluidized Bed Aeration Boat amp Dock Deicing
General Material Separation amp Collection
PressureBlower
Blower
Blower CollectionChamber
Blower
Blower
Blower
Blower
Blower
ProductBin Aerator
(Air Pads)
Blower
Blower Dock
Water
Hot Tub
Plating Bath
Spargers
Blower
Blower Ground Level
Soil
Water Table
Plating Tank
Air Knife
Hoist
Blower
Air Knife
TubeCarrier
Ejector
Bin
RotaryAirlock
DischargeTo Process
Cyclone
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Product Dimensional Listing
Blowers Shipping Wt (LBS) Carton Length (In) Width (In) Height (In)
DREN
068 16- 12 12 12
083 18- 12 12 12
101 3047 16 15 14
202 30- 16 15 14
303 4252 16 15 14
353 54- 21 16 16
404 6481 21 16 16
454 6084 21 16 16
505 8292 21 16 16
513 7699 24 12 22
523 112126 24 16 22
555 96- 21 16 16
633 241288 25 18 20
656 110117 24 16 22
6 148167 25 18 20
S7 206- 25 18 20
757 131158 25 18 20
808 285287 34 23 26
833 269297 44 29 37
858 280338 34 23 26
S9 P9 400- 34 23 26
909 373524 34 23 26
979 345533 34 23 26
1233 400- 34 23 26
14 620737 43 28 33
S13 P13 687- 43 28 33
S15 P15 909- 43 28 43
Minispirals (SE212) 2- 8 8 6
Nautilairs (NC33) 18- 16 15 14
Spiral (SL245) 42- 16 15 14
Note Model weight will vary by HP and voltage Refer to individual specication sheets to verify
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 B 1Customer Service Fax +1 2152561338 wwwametekdfscom
Industrial Chemical Processing Blowers AMETEK Dynamic Fluid Solutionsrsquo ROTRON brand has long been a world leader in regenerative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial DR (Domestic Regenerative) blowers include
Rugged cast aluminum housing cover impeller and muffler tower Removable cast iron flanges bolted to a sheet metal manifold TEFC motors on single-ended models ODP motors on all double-ended models Carbon steel shaft and zinc plated hardware Permanently sealed motor bearings for 20000-25000 hours life
Our CP (Chemical Processing Regenerative) blowers include
Chem-ToughTM surface conversion corrosion resistant treatment for aluminum castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Chemical Duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
OUTIN
(2) PLACES
85
671 99
302 100
616
155
029
39
23
641
097
371 94
152
60 DIA
35 DIA
(2) MTG HOLES
162
5876
174
216
9
553
1405
100 OD
8
22
25
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR068DJ9Y
Specification Units 081657
Motor Enclosure - Shaft Mtl - TEFC - CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 16 Kg 73
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 1 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 13 SCFMbull Maximum pressure 135 IWGbull Maximum vacuum 135 IWGbull Standard motor 18 HP TEFCbull Cast aluminum blower housing impeller amp cover slip-on steel flangesbull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Various horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR068 DR068
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 2 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
789
200
4
125
8492156
702
328 120833
1783
INOUT
448
113
8
139
685174
037
295
650
749
1651
736
DR083DC9Y - 036862
101(2 MTG HOLES)
397 DIA305
318
(2 P
LACE
S)
94
353
1869NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR083DC9Y
Specification Units 081572
Motor Enclosure - Shaft Mtl - TEFC -CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 18 Kg 82
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 3 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 24 IWGbull Maximum vacuum 232 IWGbull Standard motor 18 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR083 DR083
0 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
600 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
60
0
50
100
0
50
100
100
0
100
50
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 4 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
0 2 10 12 14 16 18 20 220
4 86
50
0
0 2 10 12 14 16 18 20 220
4 86
Temperature curves are based on standard model
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
115292
211
94
236
131
824 519
37
931
41102 MTG HOLES
312
6579
165741188
106 27
11
1997740
044
1
ROTATIONDIRECTION
1-11 12FEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR101Y9M DR101Y72M DR101Y86M CP101FB91MLR
Specification Units 038936 038937 038938 038225
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 033 033 033 033 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 3417 131206 06 13-1206 Service Factor - 135 125 125 125 Max Blower Amps Amps (A) 3417 13065 04 13065 Locked Rotor Amps Amps (A) 16482 64-5829 42 64-5829 NEMA Starter Size - 0000 00-0000 00 00-0000
Shipping Weight Lbs 30 30 30 30 Kg 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 5 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum ow 31 SCFM
bull Maximum vacuum 285 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR101 DR101
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 6 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
1178299
100
0
64 83
1130
963
394100
72
39
127
114
254
518
252 327
286
22
131
283
044
245
45
503153
81220628912263
STANDARDROTATION88
398 DIA10
1 14-11 12 NPSCSTRAIGHT THREAD(2X) CAST IRON FLANGES
(4X)
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR202Y9M DR202Y72M DR202Y86M CP202AE72MLR CP202FA91MLR
Specification Units 080564 080565 080566 038953 038227
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 33 033 033 033 033 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 3417 1206 05 1206 1206 Service Factor - 135 135 135 135 135 Max Blower Amps Amps (A) 5226 154077 057 154077 154077 Locked Rotor Amps Amps (A) 16482 6432 26 6432 6432 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 30 30 30 30 30 Kg 136 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 7 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 40 IWGbull Maximum vacuum 35 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR202 DR202
0 5 10 15 20 25 30 35 40 45 50 55
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 8 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
101(4) MTG HOLES
394
1001
2065
813
L10
0
254
519
132
1
245
64
327
831
113
287
961
2446
45
283
50
127
114
3
72
144
366
112
044
DR303AE9MDR303AE72MDR303AE86M
MODEL L (INMM)1186301211629461193303
891
2263
2 ROTATION DIRECTION
398 DIA
FEMALE THREADBOTH PORTS
1 14 - 11 12 NPSCNOTES
1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR303AE9M DR303AE72M DR303AE86M CP303FA91MLR
Specification Units 038841 038842 038843 080148
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 05 05 05 05 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 6231 13-1206 06 13-1206 Service Factor - 125 125 125 125 Max Blower Amps Amps (A) 63 163083 07 163083 Locked Rotor Amps Amps (A) 21105 10-9246 42 10-9246 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 34 42 42 42 Kg 154 191 191 191
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 9 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 48 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR303 DR303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 10 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
IN
OU
T
L12
22
311
31579
37595
12(4) MTG HOLES
1275324
513
622
115
555
512130
1018
Oslash613
041
10
356
175
292
141
130
90
158 44
156
258BOTH PORTS MODEL
DR353BR9M
DR353BR72M
L (INMM)
1397355
125317
8932268
47 DIA
1 12 - 11 12 NPSC THREAD
ROTATION DIRECTION1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR353BR9M DR353BR72M DR353BR86M CP353BR72MLR CP353FD72MLR
Specification Units 080554 080555 080556 081562 081612
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 075 075 075 075 075 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three 60 Hz Three 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 10050 3015 096 3015 3015 Service Factor - 115 125 125 125 125 Max Blower Amps Amps (A) 126 35175 10 35175 35175 Locked Rotor Amps Amps (A) 596298 15276 61 15276 15276 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 60 54 54 54 54 Kg 272 245 245 245 245
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 11 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 34 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR353 DR353
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 12 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
375
167
424
119(4) MTG HOLES
2921115
512
893
130
2268
L
4125
046
2816
0
121
830
94
718
182
4
305792 953
12633208
041 89
DR404AL58MDR404AL72MDR404AL86M
MODEL L (INMM)144136601418360213383399
FEMALE THREADBOTH PORTS
1032616
1
1 12 - 11 12 NPSC
47 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA KNOCK-OUT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR404AL58M DR404AL72M DR404AL86M CP404CU72MLR
Specification Units 037407 037406 037408 038233
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 10 10 10 10 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 11457 3015 12 3015 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 145725 4020 14 4020 Locked Rotor Amps Amps (A) 7035 210105 76 210105 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 69 64 64 64 Kg 313 29 29 29
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 58 IWGbull Maximum vacuum 50 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR404 DR404
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 14 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
IN OUT
475
325 178
1256
15
431
135
L
120
7
418
106
436
111524
133
20
69
175
114
475120
290
51
318
042 11
FEMALE THREAD
(6) MTG HOLES
MODEL
DR454R58MDR454R72M
L (INMM)
14473671331338
83 45
110
319
343
BOTH PORTS
125
10302616
451143
59 DIA
ROTATION DIRECTION
1 12 - 11 12 NPSC
1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR454R58M DR454R72M DR454R86M CP454EZ72MLR
Specification Units 080481 080480 080482 080491
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 5060 Hz Three - 5060 Hz Three - 5060 Hz Three - 5060 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 15678 4623 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 189 5226 21 5226 Locked Rotor Amps Amps (A) 8442 3216 128 3216 NEMA Starter Size - 10 0000 00 0000
Shipping Weight Lbs 73 60 60 60 Kg 331 272 272 272
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 15 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 60 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR454 DR454
0 15 30 45 60 75 90 105 120 135 150 1650
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
2240 25 51 76 102 127 153 178 204 229 255 280
15 30 45 60 75 90 105 120 135 150 165
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
00
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 16 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
IN
L
144
3
356
1418
59 DIA
(4) MTG HOLES
475
1030
1170 REF
725
191
37
REF
C B
1359 DIA
15
MODEL DR505AS58M
DR505AS72MDR505AS86MDR505K58MDR505K72M
1563397
1563397
14753741438365170431
L (INMM)
425108437111
437111
463117
463117
B (INMM)564143
525133
564143518131
C (INMM)
518131
FEMALE THREADBOTH PORTS
OUT
45
1143904
3602
366
5
184
2
485
1207
2616
2972
94
1824
3452
1 12 - 11 12 NPSC
ROTATION DIRECTION
1
718 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR505AS58M DR505AS72M DR505AS86M DR505K58M DR505K72M CP505FE72MLR CP505CT72MLR
Specification Units 037542 037543 037544 081882 037551 038239 038237
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS CHEM TEFC - SS Horsepower - 20 20 20 30 30 30 20 Voltage AC 115230 230460 575 115230 230460 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F F NEMA Rated Motor Amps Amps (A) 18291 5427 23 256128 7638 7638 5427 Service Factor - 115 115 115 115 115 115 115 Max Blower Amps Amps (A) 24115 735 30 2814 8844 8844 6834 Locked Rotor Amps Amps (A) 13869 3819 21 19497 8844 8844 3819 NEMA Starter Size - 10 0000 00 150 00 00 0000
Shipping Weight Lbs 97 82 84 91 86 86 82 Kg 44 372 381 413 39 39 372
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 17 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 73 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
0 15 30 45 60 75 90 105 120 135 150 16515 30 45 60 75 90 105 120 135 150 165 0
0
50
100
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
50
100
0
50
100
0
50
100
0
37
75
112
149
187
224 2240 25 51 76 102 127 153 178 204 229 255 280
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
0
0
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 18 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
OUTIN
182
1421
160
6
15
408
507
413
88
24
48
128
05
ROTATION
(4) MTG HOLES
106
61
224
122
BOTH PORTSFEMALE THREAD 325
360
937
18
1369346
372
129
1142896
5501397
1388
35261
59 DIA
1 12 - 11 12 NPSC
13
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR513R72 DR513R58 DR513R86 CP513EZ72LR
Specification Units 037217 037209 037773 038241
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 4623 16884 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 525 1995 185 525 Locked Rotor Amps Amps (A) 4321 12060 13 4321 NEMA Starter Size - 0000 10 00 0000
Shipping Weight Lbs 76 95 76 76 Kg 345 431 345 345
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 19 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 80 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR513 DR513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 20 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
IN OUT
3462
1397
3597
(4) MTG HOLES
564
220
7
1206
2901
3251
FEMALE THREADBOTH PORTS
1363
550
222
869
475
128
1142
L16
12
409
5
419 10
8
47
1194
1416
1443658
150
05
13
1421
3581
695
425
108
523
133
MODELDR523K72DR523K58
1591404119314905
L (INMM)
1 12 - 11 12 NPSC
ROTATION DIRECTION
59 DIA
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR523K72 DR523K58 DR523K86 CP523CS72LR
Specification Units 037210 037211 037772 038243
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-SS Horsepower - 3 3 3 3 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three-60 hz Single-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 88-8643 27135 34 88-8643 Service Factor - 115 10 10 115 Max Blower Amps Amps (A) 89445 3015 34 89445 Locked Rotor Amps Amps (A) 913457 19698 364 913457 NEMA Starter Size - 00 151 0 00
Shipping Weight Lbs 112 145 112 112 Kg 508 658 508 508
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 21 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 158 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR523 DR523
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 22 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
MODEL
DR555K72DR555K58
DR555CK72
L (INMM)
1744443
16124091738441
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
1506
1493L
Part Model Number
DR555CK72 DR555CK86 DR555K72 DR555K58 DR555K86 CP555CS72MLR
Specification Units 081100 081102 081099 081098 081101 038245
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 40 40 30 30 30 30 Voltage AC 230460 575 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 105 41 7638 256128 3 7638 Service Factor - 115 115 115 10 10 115 Max Blower Amps Amps (A) 1365 42 8844 2814 34 8844 Locked Rotor Amps Amps (A) 9447 80 8844 19497 70 8844 NEMA Starter Size - 10 0 00 151 0 00
Shipping Weight Lbs 113 137 96 91 90 90 Kg 513 621 435 413 408 408
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 23 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 92 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR555CK72DR555K72DR555K58
LegendPressureSuction
DR555CK72DR555K72DR555K58
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 24 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
OUTIN
486
241
1234L
95
165
163
441
5
1463
698 70 200508
40
215
98
50
848334 401016
FEMALE THREADBOTH PORTS
3201016
2032800
MODEL
DR6D89
DR6K72
L (INMM)
18004572
18004572
MUFFLER
2 - 11 12 NPSC
1
562 DIA
ROTATION DIRECTION
419
177 178
850
215
9
102
141
75
58(4) MTG HOLES
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR6D89 DR6D5 DR6D86 DR6K72 CP6FF72LR HiE6D89
Specification Units 027578 036212 027579 027600 038253 038071
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 50 50 50 30 50 50 Voltage AC 230460 230 575 230460 230460 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 11255 21 48 133-126 173-15678 173-15678 Service Factor - 115 10 115 115 115 115 Max Blower Amps Amps (A) 168 25 54 126 15-14874 15-14874 Locked Rotor Amps Amps (A) 165-15576 124 60 10653 165-15576 165-15576 NEMA Starter Size - 11 15 1 10 11 11
Shipping Weight Lbs 148 156 148 132 148 148 Kg 671 708 671 599 671 671
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 25 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 912 IWGbull Standard motor 50 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
designs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR6D89DR6K72DR6D5
LegendPressureSuction
DR6D89DR6K72DR6D5
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
0
50
100
52248 1 pc
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 26 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
NOTES
1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
98 (2X)249
118113000
20
51
322
10502667
818
6101549
6221580
IN OUT
DIRECTIONOFROTATION
103262
189
448
11
4881240
266676 1841
4676
17244 4380
1806 4587
13163343
105
9 26
90
16684237
2 NPSCFEMALE THREADBOTH PORTS
INMM
INCLUDES INLET FILTER
Part Model Number
DR633AY72M DR633AY86M DR633D89M CP633FG72LRM
Specification Units 081691 081693 081689 081695
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 75 75 5 75 Voltage AC 230460 575 208-230460 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 23-21105 84 169-15376 23-21105 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 198-189 79 15-13668 198-189 Locked Rotor Amps Amps (A) 17085 55 165-15576 17085 NEMA Starter Size - 21 1 1-10 21
Shipping Weight Lbs 241 241 223 241 Kg 1093 1093 1012 1093
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 27 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 275 IWGbull
bull Maximum vacuum 190 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR633AY72MDR633D89M
LegendPressureSuction
DR633AY72MDR633D89M
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 28 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
414
151
738
25
059
1052 140
1512384
L
556
141
(4X) MTGHOLES
15
15423905
746
190
456
116
Oslash7191826
225 0
6417
3
114202896
492125
572
2 NPSCSTRAIGHT THDSBOTH PORTS
MODEL L (INMM)
DR656CK72XDR656K72X
1750444516004064
12813254
551
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR656CK72X DR656CK86X DR656CK5X DR656K72X DR656K58X CP656CR72XLR
Specification Units 080582 080583 080584 080602 080603 080065
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC-CS TEFC - CS TEFC - CS CHEM TEFC-SS
Horsepower - 35 35 35 30 30 35Voltage AC 230460 575 230 230460 115230 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 10050 40 18 7437 29145 10050 Service Factor - 115 10 115 115 10 115 Max Blower Amps Amps (A) 11457 52 18 945 278139 11457 Locked Rotor Amps Amps (A) 9447 80 115 5427 17286 9447 NEMA Starter Size - 10 0 1 00 1510 10
Shipping Weight Lbs 110 114 101 103 114 110 Kg 499 517 458 467 517 499
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 29 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull
bull Maximum vacuum 89 IWGbull Standard motor 40 HP TEFCbull
bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
bull Cast iron cover for additional noise resonance
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 30 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
174
444
3
L
504
16
20
571
702
20
281
153389
167
426
063
R03179
CL OF BLOWER9
23
277 575
84
657
1675
128
50
50
71
145
178
ROTATIONDIRECTION
234
70 146 21
MODEL
DR757CK72X
DR757CK86X
DR757D89XDR757D86X
DR757D5MX
1855471
18554711855471
1855471
L (INMM)
5601422
2621031
163414
12733233
1
2 12 NPSCFEMALE THREADSBOTH PORTS
1855471
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (26) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR757CK72X DR757CK86X DR757D89X CP757FF72XLR CP757CR72XLR
Specification Units 081172 081173 081169 081178 081179
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS CHEM TEFC-SS Horsepower - 40 40 50 50 40 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 hz Three - 60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 105 40 126 126 105 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 126 42 15576 15576 126 Locked Rotor Amps Amps (A) 9447 80 19497 19497 9447 NEMA Starter Size - 10 0 10 10 10
Shipping Weight Lbs 131 128 140 140 131 Kg 594 581 635 635 594
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 31 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 83 IWGbull
bull Maximum vacuum 75 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg 0
C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR757D89XDR757CK72X
LegendPressureSuction
DR757D89XDR757CK72X
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22451 102 153 204 255 306 357 408 459 510 561
37
75
112
149
187
224
0
0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 32 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
2303
700
1100
200
OUTIN
400
800
494
1150
322
644
1638
588
1778 508
2794
818
101
6
1255
2032
2921
1636
1494
143(4) MTG HOLES
A
A
FEMALE THREADBOTH PORTS
FEMALE THREADBOTH PORTS
SECTION VIEW A-A
585
164
441
76
803204
4161
825
558
147
820
96
563 DIA
2 - 11 12 NPT
2 - 11 12 NPT
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS7X72 DRS7X86
Specification Units 036085 036144
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 19497 78 Service Factor - 115 10 Max Blower Amps Amps (A) 2412 96 Locked Rotor Amps Amps (A) 16683 66 NEMA Starter Size - 11 1
Shipping Weight Lbs 206 206 Kg 934 934
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 33 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 75 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS7
LegendPressureSuction
DRS7
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 34 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
IN OUT
L
536
421
12
143(8) MTG HOLES
875222
191485
18734757
09
229
359
912
117
529
8
C
35889
177870
FEMALE THREADBOTH PORTS
MODEL
DR808D89MXDR808AY72MX
L (INMM)2223564619314905
17434427
1575
14763749
4001
738187585
21622385685
562 DIA
1
2 12 - 8 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR808AY72MX DR808AY86MX DR808D89MX CP808FG72MXLR HiE808AY72MX
Specification Units 081222 081224 081225 081233 081228
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 75 75 50 75 75 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 17889 72 173-15678 17889 17889 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 108 147 2814 2814 Locked Rotor Amps Amps (A) 12060 60 15276 12060 12060 NEMA Starter Size - 11 1 10 11 11
Shipping Weight Lbs 285 242 195 285 301 Kg 1293 1098 885 1293 1365
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 35 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR808AY72MXDR808D89MX
LegendPressureSuction
DR808AY72MXDR808D89MX
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 36 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
NOTES
FILTER 515255 INCLUDED1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
MTG HOLEDETAIL
(4X)
20
51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
193
849
23
84213
5241331
ROTA
TION
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
IN OUT
1881 4778
17638 44801
104
426
52
19134859
1050 DIA2667
13983551
2406096
8712212
Part Model Number
DR833BB72M DR833BB86M DR833AY72M DR833AY86M CP833FH72MLR
Specification Units 081702 081704 081699 081701 081710
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 10 10 75 75 10 Voltage AC 230460 575 230460 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 31-2814 96 23-21105 84 31-2814 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 26-2412 89 212-19296 77 26-2412 Locked Rotor Amps Amps (A) 19095 73 17085 68 19095 NEMA Starter Size - 21 1 21 1 21
Shipping Weight Lbs 269 269 260 260 269 Kg 122 122 1179 1179 122
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 37 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 258 IWGbull
bull Maximum vacuum 174 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR833BB72MDR833AY72M
LegendPressureSuction
DR833BB72MDR833AY72M
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 38 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
902
OUT IN
FEMALE THREADBOTH PORTS
355
1860
400
(4) PLACES
19750
200
1016
4724
6811753
13533437
22345674
119
218
155
39
101
825
91
1000
13003302
2563
7091803
831
211
1116
829
67
101
325
73
641626
9992525
1905 X 508
L
MODEL DR858AY72WDR858BB72W
L (INMM)230658572319589
8492156
175950
2413
ROTATION DIRECTION
2 12 - 8 NPSC
75 X 200 SLOT
508
445
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR858BB72W DR858BB86W DR858AY72W CP858FH72WLR HiE858BB72W
Specification Units 038740 038742 038738 038749 038743
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 10 10 75 10 10 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 2613 105 17889 2613 2613 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 12 2814 2814 2814 Locked Rotor Amps Amps (A) 16281 65 12060 16281 16281 NEMA Starter Size - 21 1 11 21 21
Shipping Weight Lbs 280 280 264 280 280 Kg 127 127 1197 127 127
Model (Base Mount) - DR858BB72X DR858BB86X DR858AY72X Part Number (Base Mount) - 038735 038737 038736
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 39 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 125 IWGbull Maximum vacuum 1048 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR858BB72WDR858AY72W
LegendPressureSuction
DR858BB72WDR858AY72W
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 40 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
925
12003048
A
A
816
207
3
218
1 RE
F
1000
7091801
355902
FEMALE THREADBOTH PORTS
(4) PLACES
180
0 D
IA
457
2
400 DIA SLIP-ON1016
L
2349
142
10882764
554
100
025
4
254
756192
SECTION VIEW A-A
MODEL DRP9BM72CDRP9BL72C
L (INMM)3175806533448494
2
1
2 12 - 8 NPSC
ROTATION DIRECTION
56 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 PRESSURE OUTLET CONNECTION2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP9BM72C DRP9BM72D DRP9BM86C DRP9BM86D DRP9BL72C DRP9BL72D
Specification Units 037033 036275 037040 036276 036512 036513
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP-CS ODP - CS ODP-CS ODP - CS Horsepower - 20 20 20 20 15 15 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 49245 49245 20 20 37185 37185 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 6030 6030 222 222 5025 5025 Locked Rotor Amps Amps (A) 306153 306153 115 115 256128 256128 NEMA Starter Size - 32 32 2 2 22 22
Shipping Weight Lbs 400 408 464 408 380 418 Kg 1814 1851 2105 1851 1724 1896
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 41 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 116 IWGbull Maximum vacuum 95 IWGbull Standard motor 20 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP9BM72CDRP9BL72C
LegendPressureSuction
DRP9BM72CDRP9BL72C
0 80 160 240 320 400 480 560 640 720 800 880 0
0 136 272 408 544 680 816 951 1087 1223 1359 1495
80 160 240 320 400 480 560 640 720 800 880
136 272 408 544 680 816 951 1087 1223 1359 14950
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 42 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
1050 925
1200
223
3048
A
A
218
1
7091801
355902
XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX
FEMALE THREADBOTH PORTS
L
2349
100
554
254
816
207
3
56 (142) DIA (DRS9BL72)
500127756
19051000
254SECTION VIEW A-A
L (INMM)
31758065
33448494
MODEL
DRS9BM72
DRS9BL72
180
457
2
2 12 - 8 NPSC
60 X 135 SLOT(4) (DRS9BM72)
ROTATION DIRECTION
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS9BM72 DRS9BM86 DRS9BL72
Specification Units 037032 037041 036514
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 20 20 15 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 4824 20 3618 Service Factor - 115 115 10 Max Blower Amps Amps (A) 5628 204 5628 Locked Rotor Amps Amps (A) 288144 115 222111 NEMA Starter Size - 32 2 22
Shipping Weight Lbs 446 446 418 Kg 2023 2023 1896
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 43 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 206 IWGbull Maximum vacuum 157 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS9BL72CDRS9BM72C
LegendPressureSuction
DRS9BL72CDRS9BM72C
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
50
100
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 44 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
--
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
IN MM
NOTES1 TERMINAL BOX CONNECTOR HOLE 125 (318) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
Part Model Number
DR909BE72W DR909BE86W DR909BB72W DR909BB86W CP909FJ72WLR HiE909BE72W
Specification Units 081737 081739 081738 081744 038632 081735
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 15 15 10 10 15 10 Voltage AC 208-230460 575 230460 575 208-230460 208-230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 Hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 415-376188 146 2613 105 415-376188 415-376188 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 4221 17 3417 130 4221 4221 Locked Rotor Amps Amps (A) 318159 164 16281 65 318159 318159 NEMA Starter Size - 22 2 21 1 22 22
Shipping Weight Lbs 400 400 400 400 400 400 Kg 1814 1814 1814 1814 1814 1814
Model (Base Mount) DR909BE72X DR909BE86X DR909BB72X DR909BB86X Part Number (Base Mount) 038622 038626 038623 080183
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 45 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 137 IWGbull Maximum vacuum 106 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards when properly piped and
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR909BE72WDR909BB72W
LegendPressureSuction
DR909BE72WDR909BB72W
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 46 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
OUT IN
ROTATIONDIRECTION
1303302
952413
L
11252858
193490298
2489
204
518
216
88
428
8B
C D
E
L (INMM)MODEL
DR979BH72W
DR979BE86W
D (INMM) E (INMM)2907366
25386446
25816556
1319335
9882509
9882509
B (INMM) C (INMM)
12253112
10252604
10252604
8382129
8382129
8092055
6881748
6881748
11502921
DR979BE72W
1
4 NPSCPORTS
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 109 DIA (DR979BE72W)
1375 DIA (DR979BH72W)2 75 (191) X 200 (508) 4X MOUNTING SLOTS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR979BH72W DR979BE72W DR979BE86W DR979BH86W CP979FJ72WLR HiE979BE72W
Specification Units 080718 080704 080702 080719 081777
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 20 15 15 20 15 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - H H H H H H NEMA Rated Motor Amps Amps (A) 4623 4422 146 4623 4422 4422 Service Factor - 115 125 115 115 125 125 Max Blower Amps Amps (A) 6030 5226 21 6633 5226 5226 Locked Rotor Amps Amps (A) 294147 290145 93 294147 290145 290145 NEMA Starter Size - 32 22 2 32 22 22
Shipping Weight Lbs 350 300 300 350 300 300 Kg 1588 1361 1361 1588 1361 1361
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 47 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 1100 SCFMbull Maximum pressure 80 IWGbull Maximum vacuum 87 IWGbull Standard motor 15 HP TEFCbull Cast aluminum blower housing impeller amp cover cast iron flanges
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Chemical duty high efficiency inverter duty or industry-specific designsbull Vairous horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Slip-on or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR979BE72WDR979BH72W
LegendPressureSuction
DR979BE72WDR979BH72W
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 48 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
200 HP High Pressure Regenerative Blower
NOTES1 TERMINAL BOX CONNECTOR HOLE 138 (35) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
Part Model Number
DR1233BH72W DR1233BH86W CP1233GD72LRW
Specification Units 081375 081377 081379
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 20 20 20 Voltage AC 208-230460 575 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 51-4623 184 51-4623 Service Factor - 15 115 15 Max Blower Amps Amps (A) 50-4623 178 50-4623 Locked Rotor Amps Amps (A) 397199 159 397199 NEMA Starter Size - 32 2 32
Shipping Weight Lbs 400 400 400 Kg 1814 1814 1814
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 49 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 255 IWGbull Maximum vacuum 175 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR1233
LegendPressureSuction
DR1233
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
Inlet Filter part 522948
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 50 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
NOTES1 081801 DRP13BP72C MODEL SHOWN2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
PART NUMBER
081801
113028702
94423976
47211995
43010922
84721514
C
E
122131013
355790348
145436932
95024130
94824079
130533134
57314554
40010160
2050
10462657
177845171
FLEX TUBING (2X)
4rdquo - 8 NPT (2X)FEMALE THREAD
6rdquo - 8 NPSC FEMALE1533886 DEEP
125231788
G
75 X 200 SLOT191 X 508 (4X)
H
ROTATIONDIRECTION
081802
081804
081805
081798
081797
DRP13BP72C
DRP13BP72D
DRP13BP86C
DRP13BP86D
DRP13BM72C
DRP13BM72D
1130287
1130287
1130287
1130287
105526797
105526797
250163525
250163525
250463525
250463525
242661611
242661611
125231788
125231788
125231788
125231788
107727343
107727343
2508
2508
2508
2508
1383505
1383505
MODEL C INMM H INMM G INMM E INMM
INMM
Part Model Number
DRP13BP72C DRP13BP72D DRP13BP86C DRP13BP86D DRP13BM72C DRP13BM72D
Specification Units 081801 081802 081804 081805 081798 081797
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS Horsepower - 30 30 30 30 20 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 7035 7035 28 28 49245 49245 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 380190 380190 174 174 306153 306153 Max Blower Amps Amps (A) 11055 11055 36 36 6432 6432 NEMA Starter Size - 33 33 3 3 32 32
Shipping Weight Lbs 687 687 687 687 592 592 Kg 3116 3116 3116 3116 2685 2685
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 51 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 103 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP13BP72CDRP13BM72C
LegendPressureSuction
DRP13BP72CDRP13BM72C
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 52 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
944
1130
472
112
8
107743
847
1454
9501
081363
OUT
IN
1233
2736
2398
2870
1199
286
525
04
63621
51
109
2
SECTION VIEW A-A
35579035
197
950
27
3693
274
3462 2413
4241077
3132
204
952
04
BOTHPORTS
1
SLOTS75x200(19x508)(4) PLACES
3
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4rdquo-8 NPSC FEMALE THREAD BOTH PORTS3 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS5 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING6 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS13BP72 DRS13BP86 DRS13BM72
Specification Units 081800 081803 081799
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 30 30 20 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 7839 28 49245 Service Factor - 115 115 115 Max Blower Amps Amps (A) 8040 32 70153 Locked Rotor Amps Amps (A) 380190 174 306153 NEMA Starter Size - 33 3 32
Shipping Weight Lbs 646 646 562 Kg 293 293 2549
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 53 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 195 IWGbull Maximum vacuum 132 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS13
LegendPressureSuction
DRS13
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 54 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
11001311
128
8
17004318
MODELDR14DW72MW
L (INMM) D (INMM)19850331558014
L
751905
29257430
276
701
0972
2477
300762
2794
17574463
234
659
59
327
2
333
9652451
11572939
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
D
SEE NOTE 1
2332 DIA5923
1531 DIA3889
SEE NOTEOUT IN 1
NOTES1 LIFTING SLOT 100 X 170 (254 X 432)2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR14DW72MW DR14DW86MW DR14DT72MW DR14BH72MW CP14FK72MWLR HiE14DW72MW
Specification Units 081476 081479 081483 081480 081490 081497
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 30 30 25 20 30 30 Voltage AC 230460 575 230460 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 6633 265 5829 4623 6633 6633 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 9045 328 9045 6030 9045 9045 Locked Rotor Amps Amps (A) 430215 172 304152 294147 430215 430215 NEMA Starter Size - 33 3 33 32 33 33
Shipping Weight Lbs 696 694 650 600 696 696 Kg 3157 3148 2948 2722 3157 3157
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 55 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 120 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 56 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
141
411
42
588
A
2404 REF
969
296
4
1562
1250
1034
OUT IN
SECTION VIEW A-A
1238
295
3
10114
233
0 D
IA
121
2 320
1 RE
F
OU
T IN
359
2
149
4
290
1
752
9
2461
6106
3145
3967
3175
2626
750
1
591
8
307
8
813
1
A
1129
1429363
1725
11252858
43822868
39823982714281 DIA
(2 PLACES)
19(4) PLACES
508
300762
1
2
3
75 X 200 SLOTNOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 PRESSURE CONNECTION 6-8 NPSC FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP15EE72C DRP15EE72D DRP15BQ72C DRP15BQ72D DRP15BQ86C DRP15BQ86D
Specification Units 081499 081629 081501 081500 TBD TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP - CS ODP - CS ODP - CS ODP - CS Horsepower - 60 60 40 40 40 40 Voltage AC 230460 230460 230460 230460 575 575 Phase - Frequency - Three-60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 14070 14070 9648 9648 384 384 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 870435 870435 630315 630315 540270 540270 Max Blower Amps Amps (A) 17085 17085 16080 16080 64 64 NEMA Starter Size - 54 54 43 43 3 3
Shipping Weight Lbs 1025 1025 923 923 923 923 Kg 4649 4649 4187 4187 4187 4187
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 57 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 115 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 58 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
2469
A
OU
T
IN
IN
OUT
A
SECTION VIEW A-A
972
BOTHPORTS
1
4
2
5
3
1082743
12503175
1563962
600
152
4
286
726
4
1313327
140
355
610
626
92
1343404 104
2642
17254382
28401118
1162946
1293277
3929957
234
594
4
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 FOUR MOUNTING SLOTS 75 (19) X 200 (508)4 TWO LIFTING SLOTS 100 (254) X 170 (432)5 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS6 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING7 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS15BQ72 DRS15BQ86
Specification Units 081502 TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 40 40 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 9648 384 Service Factor - 115 115 Max Blower Amps Amps (A) 14070 52 Locked Rotor Amps Amps (A) 630315 216 NEMA Starter Size - 43 3
Shipping Weight Lbs 923 923 Kg 4187 4187
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 59 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200 IWGbull Maximum ow 925 SCFM
bull Maximum vacuum 1347 IWGbull Standard motor 40 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Quiet operation within OSHA standards when properly piped or mued -
1 inlet muer included
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS15
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
40
80
120
160
200
240
0
100
200
300
400
500
600
0
50
100
0
50
100Temperature curves are based on standard model
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 60 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers Our environmental EN blowers are designed the same as the DR blowers except added features include
Heavy duty cast aluminum manifold Our spark resistant housing cover impeller muffler tower and manifold are
vacuum impregnated Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Explosion-proof motors standard and available in a variety of world voltages All metal-to-metal surfaces are sealed with RTV sealant
Various UL explosion-proof listings Consult factory
Environmental (EN) regenerative blowers are also available in our Chemical Processing (CP) configuration
Chem-ToughTM surface conversion corrsion resistant treatment for all castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less
Chemical duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
7741956
6131557
13753493
8622190
4651181
963
244
6
140
1
312793325
826
650
752 1651
1910
4131049
125
1
553
1 - 11 12 NPSCFEMALE THREADBOTH PORTS
1
ROTATIONDIRECTION
38 (96) DIA2X MTG HOLES
100
355
9
317
8
140
5
254
040
102
NOTES1 TERMINAL BOX CONNECTOR HOLE 75rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN101AG58L EN101AG91L CP101FN58LR CP101FN91LR
Specification Units 038171 038019 080622 038950
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 7437 9045 7437 9045 Locked Rotor Amps Amps (A) 63 1575 63 1575 Service Factor Amps (A) 3819 8945 3819 8945 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 47 47 47 47 Kg 213 213 213 213
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 25 IWGbull Maximum vacuum 23 IWGbull Standard motor 05 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN101
LegendPressureSuction
EN101
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 2Customer Service Fax +1 2152561338 wwwametekdfscomcom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
OUTIN
338 327
575
108
2
859 831
274
8
048
197
406
891
39450
1031
10(4) MTG HOLES
12043058
137
3485
7914
71
698
177
3
961
1090
397 DIA
1
122
2441
1001
2263
1 14 - 11 12 NPSCFEMALE THREADBOTH PORTS
146
12769
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREADgt2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN303AG58L EN303AG91L CP303FN58LR CP303FN91LR
Specification Units 038172 038026 080247 038954
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 9045 1575 9045 1575 Locked Rotor Amps Amps (A) 7236 16383 7236 16383 Service Factor Amps (A) 3819 89445 3819 89445 Starter Size - 000 0000 000 0000 Thermal Protection - 10 135 10 135 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 52 52 52 52 Kg 236 236 236 236
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP explosion-proof
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN303 EN303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor
628
375
492
666
512
893
159
5
112
1692
125
2268
130(4) MTG HOLES
L12
23
311
2
304762 953
11632954
119
718
182
4
2921
044
10132573
EN404AR72MLEN404AR58MLMODEL L (INMM)
1641416815503937
ROTATION DIRECTION
1
47 DIA
115 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN404AR58ML EN404AR72ML CP404FQ58MLR CP404FQ72MLR
Specification Units 038173 038174 080075 038958
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 10 10 10 10 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 208-230460 115230 208-230460 Max Blower Amps Amps (A) 114569 3216 114569 3216 Locked Rotor Amps Amps (A) 14472 3618 14472 3618 Service Factor Amps (A) 7236 202101 7236 202101 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 81 64 81 64 Kg 367 29 367 29
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor ATEX model certified
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 52 IWGbull Maximum vacuum 48 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN404
LegendPressureSuction
EN404
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
50
100
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
177
3
488
3175
120
7
698
125
475
4751206
107
4501143
327
831 452
(6) MTG HOLES
3327
178
192
042
135
3
1310
15
1367
2896
2616
538
114 REF
1030
343
7
18704750
1
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN454W58ML EN454W72ML CP454W72MLR CP454FR72MLR
Specification Units 080487 080488 080490 080494
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-CS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 115208-230 230460 230460 230460 Motor Nameplate Amps Amps (A) 1579-75 4623 4523 4623 Max Blower Amps Amps (A) 19109-95 5628 5628 5628 Locked Rotor Amps Amps (A) 96-48 3216 3216 3216 Service Factor - 10 0000 0000 0000 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 90 84 84 84 Kg 408 381 381 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 59 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN454 EN454
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN505AX58ML EN505AX72ML CP505FS58MLR CP505FS72MLR
Specification Units 038177 038178 080655 038962
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 20 20 20 Phase - Frequency - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Voltage AC 115230 230460 115230 230460 Motor Nameplate Amps Amps (A) 2211 5829 2211 5829 Max Blower Amps Amps (A) 2412 6432 2412 6432 Locked Rotor Amps Amps (A) 11256 5628 11256 5628 Service Factor - 10 00 10 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 92 84 92 84 Kg 417 381 417 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull Maximum vacuum 70 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN505AX72MLEN505AX58ML
LegendPressureSuction
EN505AX72MLEN505AX58ML
0
50
100
0
50
100
0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
OUTIN
442
112340
44
372 550
1364
1387
1397945
3465
(4) MTG HOLES
2248
822
35
569
475
128
1206
140
3251
05
127
1819
14213609
669170
553
15703988
159
2
3523
15
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN513W58L EN513W72L CP513FR58LR CP513FR72LR
Specification Units 038183 038037 038966
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115208-230 230460 115208-230 230460 Max Blower Amps Amps (A) 1579-75 4623 1579-75 4623 Inrush Amps Amps (A) 19497-90 5427 19497-90 5427 Service Factor Amps (A) 84-42 3216 84-42 3216 Starter Size - 10 0000 10 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 99 93 99 93 Kg 449 422 449 422
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 75 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN513 EN513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
OUTIN
5501397
(4) MTG HOLES
3609
571
1142
128
4751206
145
2901
3251
19194874
6561666
160
140
87 7
16556
1412
15683983
15
1421
575
146
10
5012
7
143
836
53
222
6058
6922
38
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN523M5L EN523M72L CP523FU5LR CP523FU72LR
Specification Units 038223 038184 TBD 038968
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 230 230460 Max Blower Amps Amps (A) 155-145 7437 155-145 7437 Locked Rotor Amps Amps (A) 181-167 84 181-167 84 Service Factor Amps (A) 94-88 6231 94-88 6231 Starter Size - 1 00 1 00 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D I-D I-D I-D
Shipping Weight Lbs 126 126 150 126 Kg 572 572 68 572
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN523 EN523
0
50
100
0
50
100
0
50
100
0
50
100
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
850
200
400
558
1638
598
800
1150
215
9
508
141
7
101
6
4161
1519
2032
2921
143(4) MTG HOLES
423
916
69
FEMALE THREADBOTH PORTS419
106416
222
825
209
6
7181824
7001778
L
16184110
7751969
095246
6371618
MODEL L (INMM)
562 DIA
2 - 11 12 NPSC
NOTE 1
2055207EN6F72L20845292EN6F5L
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD
POSITIONED AT 12 OrsquoCLOCK2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN6F5L EN6F72L EN6F86L CP6FW5LR CP6FW72LR
Specification Units 038361 038180 038438 TBD 038978
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 50 50 50 50 50 Phase - Frequency Voltage - Single-60 hz Three-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 575 230 230460 Max Blower Amps Amps (A) 195 147 57 195 147 Locked Rotor Amps Amps (A) 23 147 63 23 147 Service Factor Amps (A) 175 15276 38 175 15276 Starter Size - 2 10 0 2 10 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 190 167 167 190 167 Kg 862 757 757 862 757
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 85 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
Muffler included (part 522948)
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN6F72LEN6F5L
LegendPressureSuction
EN6F72LEN6F5L
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
bull
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
103 262
A C
DIRECTION OF ROTATION
B
ROTA
TIO
N
1171 2974
20 51
322
818
10
59
269
0
IN OUT
622 98 (2X) 1580 610 249 154926611811
6763000 D
1841
2 - 11 12 NPSCFEMALE THREAD
1806 4676 BOTH PORTS
4587
IN MM 512
MTG HOLE 130
591
150 DETAIL
(4X) MODEL A B C DNOTES
1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD EN633 181 1894 167 173 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN EN833 182 1959 180 176
PartModel Number
CP633FY72LREN633BA72LM
081697Specification Units 081698
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1785 1785 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Lbs 288 288Shipping Weight Kg 1306 1306
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200195 IWGbull
bull Maximum vacuum 155155 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0
20 40 60 80 100 120 140 160 180 200 220
34 68 102 136 170 204 238 272 306 340
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
414
746
1542
696
538
1052
3917
176
818
95
STRAIGHT THDS2 NPSC
BOTH PORTS
136
7
(4X) MTGHOLES
19374920
151
738
25
551140
05915
1512
1826719
231
587
064
173 492
125
382512813254
114202901
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN656M5XL EN656M72XL EN656M86XL CP656FU72XLR
Specification Units 080060 080059 080058 080142
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 208-230 208-230460 575 208-230460 Motor Nameplate Amps Amps (A) 155-145 7437 30 7437 Max Blower Amps Amps (A) 17 105 41 105 Locked Rotor Amps Amps (A) 95-86 5427 216 5427 Service Factor - 1 00 0 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 142 117 117 117 Kg 644 531 531 531
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull
bull Maximum vacuum 73 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN656M72XLEN656M5XL
LegendPressureSuction
EN656M72XLEN656M5XL
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
15363901
233517
24
437
9
194
349
35
5931
950
604
2413
130033021534
445175
168
242
72
258
610
18
5731455
10332624
8502159
16644227
1000254
166
9
233
2
663
657
261
918
ROTATIONDIRECTIONOUT IN
2 12 NPSCFEMALE THREADSBOTH PORTS
1
75 X 200 SLOT19508(4) PLACES
INMM
PartModel Number
EN757FL5MWL CP757FX5MWLR
Specification Units 081333 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS CHEM XP-SS Horsepower - 55 55 Phase - Frequency - Single-60 hz Single-60 hz Voltage AC 230 230 Motor Nameplate Amps Amps (A) 217 217 Max Blower Amps Amps (A) 299 299 Locked Rotor Amps Amps (A) 155 155 Service Factor - 1 1 Starter Size - 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D I-D
Shipping Weight Lbs 158 158 Kg 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 21Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
0
0
0
20
40
60
80
100
120
0
50
100
0
50
100
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Legend Pressure Suction
EN757FL5WL
120 40 80 120 160 200 240 260 300 340 380 420
68 136 204 272 340 408 442 510 578 546 714
mba
r
0
50
100
150
200
250
300
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
R031
CL OF BLOWER79
19906316
505
657
261
166
966
3
ROTATIONDIRECTION
L
174
444
3
182
718
MODELEN757M72XLEN757F72XL
L (INMM)1972500921005334
15363886
284
20
508
559
142
715
181
6
16754255
923
234
4
16094087
IN OUT
088
5601422
5731461
10372634
15353899
2 12 NPSCFEMALE THREADSBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
IN
MODELPART NO
NAMEPLATEMOTOR
INMM
PartModel Number
EN757M72XL EN757M86XL EN757F72XL CP757FW72XLR CP757FU72XLR
Specification Units 081176 081177 081174 081180 081181
Motor Enclosure - Shaft - XP-CS XP-CS XP-CS CHEM XP-SS CHEM XP-SS Mtl Horsepower - 30 30 50 50 30 Voltage AC 208-230460 575 208-230460 208-230460 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three - 60 Hz Three-60 Hz Three - 60 Hz Insulation Class - B B B B B NEMA Rated Motor Amps Amps (A) 7236 30 147 147 7236 Service Factor - 10 10 10 10 10 Maximum Blower Amps Amps (A) 105 40 1575 1575 105 Locked Rotor Amps Amps (A) 5447 22 15276 15276 5427 Starter Size - 00 0 11 11 00
Shipping Weight Lbs 158 158 158 158 158 Kg 717 717 717 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN757F72XLEN757M72XL
LegendPressureSuction
EN757F72XLEN757M72XL
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 24Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options Sealed Regenerative Blower wExplosion-proof Motor
2335 103359311536 2624 573
101
825
86
168
242
72
918
233
2 6
57
261
663
166
9
3901
1
OUT
1455
IN ROTATION DIRECTION
2 12 NPSC FEMALE THREADS BOTH PORTS
850
194
349
35
172
443
79
950175 2159
NOTES 1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
604
2413
1300 33021534
445 IN
MM 75 X 200 SLOT 19508 (4) PLACES 1664
4227
1000 254
PartModel Number
EN757FL5MWL EN808FL5MWL CP757FX5MWLR CP808FX5MWLR
Specification Units 081333 081231 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 55 55 55 55 Phase - Frequency - Single-60 hz Single-60 hz Single-60 hz Single-60 hz Voltage AC 230 230 230 230 Motor Nameplate Amps Amps (A) 217 217 217 217 Max Blower Amps Amps (A) 299 299 299 299 Locked Rotor Amps Amps (A) 155 155 155 155 Service Factor - 1 1 1 1 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Class B - Pilot Class B - Pilot Class B - Pilot XP Motor Class - Group - Duty I-D Duty I-D Duty I-D Duty I-D
Lbs 158 338 158 338Shipping Weight Kg 717 1533 717 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
D 25USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom ____
____
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWG bull Maximum vacuum 75 IWG bull Standard motor 50 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
Temperature curves are based on standard model
Legend Pressure Suction
EN808FL5MWL
0
50
100
0 40 80 120 160 200 240 260 300 340 380 420
0 68 136 204 272 340 408 442 510 578 546 714
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 26Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
(8) MTG HOLES
IN OUT
692
850
738 355
1415
709
088
224
111
3
189
1
902
1801
358
909
282
7
480
3
1875
2159
35941758
143
23565984
211
253
7
8752223
8602174 125
318
6751715
117
429
87
185470
3749
15754001
1476
17434427
562 DIA
ROTATIONDIRECTION
FEMALE THREADBOTH PORTS
2 12 - 8 NPSC
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT CONDUIT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN808BA72MXL EN808BA86MXL CP808FY72MXLR
Specification Units 081229 081230 081234
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 75 75 75 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 Motor Nameplate Amps Amps (A) 18693 74 18693 Max Blower Amps Amps (A) 220110 81 220110 Locked Rotor Amps Amps (A) 12663 56 12663 Service Factor - 11 1 11 Starter Size - 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 287 287 287 Kg 1302 1302 1302
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 27Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 85 IWGbull Maximum vacuum 90 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN808 EN808
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 28Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
MTG HOLEDETAIL
(4X)
20 51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
103262
11712974
ROTA
TIO
N
IN OUT
266676
AC
D
B
18414676
105
9 26
90
1806 4587
EN633 181 1894 167 173
MODEL A B C D
EN833 182 1959 180 176
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN833BA72LM CP833FY72LRM
Specification Units 081712 081708
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1995 1995 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Shipping Weight Lbs 297 297 Kg 1347 1347
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 29Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant bull bull Maximum pressure 200195 IWG bull Maximum vacuum 155155 IWG bull Standard motor 75 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions
Inch
es o
fW
ater m
bar
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
60 Hz
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model 0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 30Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
189
5692
1300
817
105
0
218
1
245
675
1096
821
709
1548
1860
481
31758
622
3
554
0
207
526
67
1714
2085
2784
4724
3932
1801
3302
FEMALE THREADBOTH PORTS
191485
13533437
23345928
9462403
9502413
17510752731
MODEL EN858BA72WL
L (INMM)23656007
EN858BD72WL 26006604
L
ROTATION DIRECTION
2 12 NPSC
NOTE 1
OUT IN
445
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN858BD72WL EN858BD86WL EN858BA72WL CP858FZ72WLR
Specification Units 038744 038745 080070 038980
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 100 100 75 100 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 2412 96 18693 2412 Max Blower Amps Amps (A) 3015 116 2613 3015 Locked Rotor Amps Amps (A) 234117 93 12663 234117 Service Factor - 21 1 11 21 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 338 338 326 338 Kg 1533 1533 1479 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 31Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN858D72WLEN858BA72WL
LegendPressureSuction
EN858D72WLEN858BA72WL
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 32Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
834
2118
IN OUT
EN909BG72WL - 038629
FEMALE THREADBOTH PORTS
9502413
24736281
723
185715994031
137348
259
657
9
202
5
15503698
300643
913
231
9
105
266
7
388 11
1
852159
1075
2731
846
21491163520
9062758
MODEL EN909BG72WL
L(INMM)30177663
EN909DB72WL 23666010
L
ROTATION DIRECTION
4 - 8 NPSC
(4) PLACES75 X 200 SLOT
SEE NOTE1
514
4
INMM
PartModel Number
EN909BG72WL EN909BG86WL EN909BD72WL CP909GA72WLR
Specification Units 081741 081736 081743 038982
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 15 15 10 15 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 3618 144 2412 3618 Max Blower Amps Amps (A) 4824 18 3216 4824 Locked Rotor Amps Amps (A) 240120 100 234117 240120 Service Factor - 22 2 21 22 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 524 524 504 524 Kg 2377 2377 2286 2377
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 33Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN909BG72WLEN909BD72WL
LegendPressureSuction
EN909BG72WLEN909BD72WL
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
50
100
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
0
50
100Temperature curves are based on standard model Temperature curves are based on standard model
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 34Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
ROTATIONDIRECTION
4 NPSCPORTS
150 DIA (381)LIFTING LUG
1
9002286
31257938
11382891
5691145
9752477
19254890
8752223 1111
2822
13063317
10372634
25
3264
31
217
755
30
122
531
12
24
762
7
200508
191485
07
619
3NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN979BK72WL EN979BK86WL CP979GB72WLR
Specification Units 080724 082277 081778
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 20 20 20 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 575 230460 Max Blower Amps Amps (A) 4623 184 4623 Locked Rotor Amps Amps (A) 6030 24 6030 Service Factor Amps (A) 334167 118 334167 Starter Size - 32 2 32 Thermal Protection - 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 533 533 533 Kg 2418 2418 2418
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 35Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 90 IWGbull Maximum vacuum 90 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
EN979
LegendPressureSuction
EN979
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 36Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
117
297
4
309
678
638
110027940
16994316426032
1025
3007612
233259239
96424486
44619
OUT IN
1757
96524503
127632410
327
15
243
617
22
86121869
301476556
L
143236373
128
8 153238913
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
INMM
MODEL LENGTH (INMM)EN14BK72MWL 32128159EN14DX72MWL 311857921
PartModel Number
EN14BK72MWL EN14DX72MWL EN14DX86MWL CP14GB72MWLR CP14GC72MWLR
Specification Units 081485 081486 081487 TBD 081491
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 30 30 20 30 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 200-230460 575 230460 200-230460 Max Blower Amps Amps (A) 4623 75-6633 265 4623 75-6633 Locked Rotor Amps Amps (A) 6030 8241 33 6030 8241 Service Factor Amps (A) 294147 448224 226 294147 448224 Starter Size - 32 33 3 32 33 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 601 737 737 601 737 Kg 2726 3343 3343 2726 3343
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 37Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 144 IWGbull
bull Maximum vacuum 115 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 38Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motor-less) Blowers AMETEK Technical amp Industrial Productsrsquo ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial (_RD) Remote Drive Blowers are motorless models built with DRENCPSL blower features and include
Rugged cast-iron arbor and bearing suspension system Oversized shaft to withstand heavy-duty side loads Precision balanced impellers for low vibration operation High speed versions built with heat treated impellers available
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
MF573RD
NOTES1 CONTACT FACTORY FOR PULLEY OPTIONS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
AIR OUT
ROTATION
AIR IN
C
E
B
A
F
D G
Specification INMM
Model Number Part Number A B C D E F G
MF573RD 026940 363 125 658 175 175 175 356 922 318 1671 445 445 445 904
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
10000 RPM
12000 RPM
14000 RPM
10000 RPM12000 RPM
14000 RPM
10000 RPM
12000 RPM14000 RPM
14000 RPM
10000 RPM
12000 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph
0
4
8
Do not exceed maximum speed shown on each graph
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
SL2RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
ROTATION
FLAT
14-20 UNC - 2B X 444 HOLES EQ SPACED ON 443 DIA
N
B
J
K
E
G
F
T
D
C
H
A
PS
Q
L
4 MTG HOLES
4 MTG HOLES(SAME AS OPPOSITE SIDE)
IN OUT
R
Specification INMM
Model Number Part Number A B C D E F G H J K L M N P Q R S T
SL2RD 026125 733 588 992 145 100 500 175 25 175 141 262 175 496 331 300 992 473 100 1862 1494 252 368 254 127 445 64 445 358 665 445 126 841 762 252 12 254
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
AIR AT 1
00˚C
25˚C50˚C75˚C
6000 RPM5500 RPM
5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
6000 RPM5500 RPM
5000 RPM4500 RPM
4000 RPM3500 RPM3000 RPM2500 RPM
6000 RPM5500 RPM5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
25˚C50˚C75˚C
AIR AT 100˚C
6000 RPM5500 RPM
5000 RPM4500 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph or 100degC
0
10
20
Do not exceed maximum speed shown on each graph or 100degC
0
10
2015
05
05
15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 404RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR404RDNT 036439 560 115 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 1422 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
EN404RDML 038334 1276 1150 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 3241 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
75˚CAIR AT 100˚C
50˚C
25˚C
2500 RPM
1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM
25˚C 6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
55004500350025001750
65006500
55004500350025001750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Do not exceed maximum speed shown on each graph or 100degC
01
08
70
Do not exceed maximum speed shown on each graph or 100degC
20
04
40
01
08
70
20
04
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 505RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR505RDNT 036437 568 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 1443 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
EN505RDML 038336 1458 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 3703 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000550045003500
2500
1750
75˚C
AIR AT 100˚C
50˚C
25˚C
2500 RPM1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM25˚C
6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
60005500
450035002500
1750
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC
15
20
10
Do not exceed maximum speed shown on each graph or 100degC
40
08 04
15
20
1040
08 04
Air Flow Rate - SCFM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 513RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR513RDNT 038076 607 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 1542 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
EN513RDL 038341 1190 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 3023 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM
2500 RPM
100˚C75˚C
50˚C
25˚C
60005500
450035002500
60005500
450035002500
2500 RPM
6000 RPM
5500 RPM
3500 RPM
100˚C75˚C
50˚C
25˚C
4500 RPM
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
4
8
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 523RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR523RDNT 037223 796 138 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 2022 3505 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
EN523RDL 038342 138 1555 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 3505 395 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
25˚C
AIR AT 50˚C
45003500250017505500
6000
5500 RPM6000 RPM
25˚C4500 RPM
3500 RPM2500 RPM
1750 RPM
5500 RPM6000 RPM
4500350025001750
55006000
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 230 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 229 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
8
16
0
8
16
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 6Customer Service Fax +1 2152561338 wwwametekdfscom
Dual muers provided in place of muer tower
____
Remote Drive (Motorless) Blowers
DRENCP 6RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR6RDNT 036185 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
EN6RDL 038343 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM1750 RPM
AIR AT 100˚C
50˚C
25˚C
55004500350025001750
2500 RPM 1750 RPM
2500 RPM
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
550045003500
25001750
75˚C
25˚C
50˚C
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 656RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR656RDNT 080610 735 1244 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 1867 3160 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
EN656RDL 080061 1512 146 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 385 3708 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM1750 RPM
100˚C
50˚C
25˚C
600055004500
350025001750
2500 RPM
1750 RPM
2500 RPM
6000 RPM
5500 RPM
4500 RPM
3500 RPM
100˚C
50˚C
600055004500
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
15
30
0
15
30
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 8Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motorless) Blowers
DRENCP 757RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR757RDNT 081847 667 1506 1725 362 25 100 175 505 450 619 644 250 922 640 450 1611 1694 3825 4382 919 64 254 445 128 1143 1572 1636 635 2342 1626 1143 4092
EN757RDML 081848 1506 2023 1725 362 25 100 175 450 505 619 644 250 922 640 450 1611 3825 5138 4382 919 64 254 445 1143 128 1572 1636 635 2342 1626 1143 4092
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
50˚C
5500
450035002500
2500 RPM2500 RPM
5500 RPM
4500 RPM
3500 RPM
5500450035002500
75˚C
50˚C
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
AIR AT 100˚C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 858RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR858RDNT 036413 851 1930 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 2162 4902 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
EN858RDL 038746 1930 2222 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 4902 5644 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4000 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4000
350025001750
75˚C
50˚C25˚C
AIR AT 100˚C
25˚C
4000 RPM
3500 RPM
2500 RPM1750 RPM
4000
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 909RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR909RDNT 081962 853 228 2322 350 500 1375 200 765 500 970 834 301 1297 902 500 198 2167 581 5898 889 127 349 508 194 127 2464 2118 765 3294 2291 127 5029
EN909RDL 081742 228 2451 2322 350 500 1375 200 765 500 970 834 400 1297 902 500 198
5791 6226 5898 889 127 349 508 194 127 2464 2118 1016 3294 2291 127 5029
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4500350025001750
75˚C
50˚C
AIR AT 100˚C
4500 RPM
3500 RPM2500 RPM1750 RPM
4500350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 979RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR979RDNT 080760 105 235 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 2667 5969 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
EN979RDL 080761 235 2517 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 5969 6393 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
3700
350025001750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM2500 RPM
1750 RPM
37003500
25001750
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 1233RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 FILTER 515256 1PIECE
ROTATION
J +- 12
A
Q +- 12E
G +- 25
D
SEEDETAIL AA
DETAIL AA
C +- 06
236599
03910
B
(4X) F
(4X) R
(2X) H
(2X) T
OUTINK +- 12
L +- 12
M +- 25
N +- 25
(2X) PNPSC THD
Specification
Model Number Part Number A B C D E F G J H K L M N P Q R T
DR1233RD 081853 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 669 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 1699 236 348
EN1233RDL 081854 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 689 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 175 236 348
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3500 RPM
2850 RPM
AIR AT 100˚C
50˚C4000 RPM
4300 RPM
40003500
2850
4500400035002850
4300
3500 RPM
2850 RPM
4000 RPM
4500 RPM
75˚C
AIR AT 100˚C
50˚C
75˚C
80 120 160 200 240 280 320 360 400 440 480 520
136 204 272 340 406 476 544 612 680 748 846 884
0
50
100
150
200
250
300
0
100
199
298
398
498
598
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
5
15
25
5
15
25
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS E 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 14RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR14RDNT 081475 987 2224 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 2507 5649 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
EN14RDL 081488 2224 3014 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 5649 7656 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
370035002500
1750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM
2500 RPM1750 RPM
3700
350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
30
60
0
30
60
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 14Customer Service Fax +1 2152561338 wwwametekdfscom
Application Specific Regenerative Blowers Specialty blowers for Commercial Spa High Temperature Natural Gas and Gasoline Vapor Recovery applications
Our industrial NC (NautilairTM Centraxial) blowers include Fiberglass or aluminum housing Aluminum impellers Permanently sealed bearings for 50000 hours life
Our instrument grade and variable flow SE (MinispiralTM Regenerative) blowers include AC and DC versions available for world voltages and maximum flow variability Glass filled molded phenolic impeller aluminum and phenolic case 30000 hour bearing life Small size and lightweight construction
Quiet to NC-47 office equipment standards
Our instrument grade SL (Spiral Regenerative) blowers include Rugged diecast aluminum housing endbells and impellers
Compact size with encased muffler for maximum noise reduction Low amp draw with highly efficient motor
Permanently sealed bearings for 40000 hours life Hermetically sealed models designed for glovebox use
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
111
8032
180 REF
813
4572
44
REF
TYP
411 DIA1044165
4191
Oslash224 DIA
569
210
533
4
416
REF
105
66
212 DIA
1
2
OUT
IN
INMM
PartModel Number
SE2B21 SE62B21 SE2B21A
Specification Units 081901 037395 080694
Phase - Frequency - Single-5060 Hz - Single-5060 Hz Voltage AC 110115 24 110115 RPM RPM 28503400 28503400 28503400 Insulation Class - B B B Full - Load Amps Amps (A) 1714 - 1714 Locked Rotor Amps Amps (A) 1715 - 1715
Shipping Weight Lbs 19 19 19 Kg 09 09 09
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
2 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L mdashdb
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Maximum vacuum 35 IWGbull Maximum ambient 40degC
bull Shaded pole motor with ball bearings
bull B10 bearing life 30000 hoursbull Weight 11 lb (05 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONSbull Sealed unitsbull International voltage and frequency (Hz)
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
LegendPressureSuction
Minispiral
LegendPressureSuction
Minispiral
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
2 leads 20 gaTFE coveredUL style 1180 (12 long stripped 50)
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
44
REF
TYP
111
8
032813
180 REF4572
411 DIA1044
1654191
Oslash224 DIA
569
210
533
4
416
REF
10
566
212 DIA
2
OUT
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12V21 SE24V21
Specification Units 037433 037434
Voltage Range VDC 9-15 24-32 RPM RPM 3600-6000 5500-6800 Insulation Class - B B Full - Load Amps Amps (A) 050-10 06-09
Weight Lbs 086 086 Kg 04 04
WARNING ndash ON MDC MODELEXCEEDING 10 AMP MAY DAMAGE CIRCUIT BOARD
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 70103 IWG (1532 volts)bull Maximum vacuum 70103 IWG (1532 volts)bull Maximum ambient 40degC
amp impellerbull Shaded pole motor with ball bearings
bull B10 bearing life 20000 - 30000 hoursbull Weight 086 lbs (039 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed control
Blower Performance at Standard Conditions12 V-MDC 24 V-MDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
15 V-MDC
12 V-MDC
9 V-MDC
32 V-MDC
26 V-MDC
24 V-MDC
LegendPressureSuction
Minispiral MDC
LegendPressureSuction
Minispiral MDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
BOTH PORTS
057
OD
145
114290
199505
217
552
226
574
116295
02564063
160
092234
054137
083211 0
75 O
D19
1
Oslash1
8346
5
119302
282716
066168
350889
421
106
9
Oslash 4201067
211
536
186
472
057
145
044
112
165419
067170
4071034
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 12
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21 SE24RE21
Specification Units 081548 080847
Voltage Range VDC 75-15 24-32 RPM RPM 4400-8750 4400-8750 Insulation Class - B B Full - Load Amps Amps (A) 12-25 12-16
Weight Lbs 10 10 Kg 05 05
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L db
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull 12 VDC operation 75-15 VDCbull 24 VDC operation 15-32 VDC
bull Maximum pressure 207 IWG (15)bull Maximum vacuum 207 IWG (15)bull Maximum ambient 40degC
amp impellerbull Brushless DC motor with integrated control electronics
bull Stainless steel ball bearings permanently lubricated for B10 bearing life 20000 - 30000 hours
bull Weight 19 lbs (086 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull International voltage and frequency (Hz)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
220 17 34 51 68 85 102 119 136 153
0 1 2 3 4 5 6 7 8 9
20
18
16
14
12
10
8
6
4
2
55
50
45
40
35
30
25
20
15
10
5
15 V-HDC
12 V-HDC
9 V-HDC75 V-HDCLOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
BOTH PORTS
056
ID14
2
106269
192488
217
552
224
569
130330
02564063
160
092234
053135
080203 0
75 O
D19
1 T
YP
Oslash1
750
444
119302
272691
066168
350889
416
REF
10
69
Oslash 4111044
210
5331
8547
00
5614
20
4210
7 R
EF
T
YP
165419
067170
4061031
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 14
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21A
Specification Units 081881
RPM RPM 7397 - 13205 Voltage Range VDC 75 - 15 Insulation Class - B Full - Load Amps Amps (A) 27 - 62
Weight Lbs 25 Kg 11
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOU
ND
PO
WER
LEV
EL
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
EQU
IVA
LEN
T SO
UN
D P
RES
SUR
E LE
VEL
db (r
e 0
0002
mic
roba
r)3
FEET
(09
1 M
ETER
S) F
RO
M N
OIS
E SO
UR
CE
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 26 IWG (15)bull Maximum vacuum 26 IWG (15)bull Maximum ambient 40degC
bull Brushless DC motor with integrated control electronicsbull Stainless steel ball bearings permanently lubricated for B10 bearing life
20000 - 30000 hoursbull Weight 19 lbs (086 kg)bull Compact high performance design 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull Speed sensing output (FPS)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
24
260 17 34 51 68 85 102 119 136 153 170 187 204 221
0 1 2 3 4 5 6 7 8 9 10 11 12 13
22
20
18
16
14
12
10
8
6
4
2
0
50
55
60
65
45
40
35
30
25
20
15
10
5
0
15 V-HDC
12 V-HDC
75 V-HDC
LOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
OUT IN
841
666
412
104
7
445
734
742142
175
OD
331
162
412
587
292
289
3091
1991
100
120 175
254
305 445
1217
300 TYP762
784
1491
25 -20 UNC -2B X 31 DEEP(4 MOUNTING HOLES EACH END)
997
498
263
160
ID
253
2
126
2
406
229582
OPTIONAL OUTLET TRIMMER
OPTIONAL INLET TRIMMER
12 CONDUIT HOLE (1) EACH END
56
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL2P2 SL2P52 SL2P90
Specification Units 036000 036013 036018
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 5 5 5 Voltage AC 115 208-230 380460 Phase - Frequency - Single-5060 Hz Single 60 Hz Three-5060 Hz Insulation Class - B B B Full - Load Amps Amps (A) 245360 95154 3441 Service Factor - 10 10 10 Locked Rotor Amps NEMA Amps (A) 100 43 19 Starter Size - 0000 0000 0000
Shipping Weight Lbs 27 27 27 Kg 122 122 122
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum vacuum 313 IWGbull Standard motor 05 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL2 Spiral SL2
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
656 MAX1666
7211831
12rdquo CONDUIT HOLE(1) EACH END
IN
OUT
1524600
130
3 M
AX
331
997
253
2
300 TYP762
924
5761463
2347
412
104
7
412
162
138351
292
287729
317805
25-20 UNC-2B X 31 DEEP(6) MOUNTING HOLES EACH END742
160
ID
175
OD
445
406
666
262
989
DIA
251
2
456 MAX1158
CAPACITORS ON SINGLEPHASE MODELS ONLY
PartModel Number
SL4P2 SL4P52
Specification Units 036009 036027
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 370380 229220 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 60 IWGbull Maximum vacuum 558 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL4 Spiral SL4
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
IN
OUT
762
1831
331
805729
742351
412
666
PHASE MODELS ONLY
(6) MOUNTING HOLES EACH END
(1) EACH END
6001524
1666656 MAX
721
130
3 M
AX
300 TYP
412 162
175
OD
138 292
287 317
104
7
445
456 MAX1158
262997
253
2
9242347
5761463
160
ID
40
6
989
DIA
25
12
CAPACITORS ON SINGLE
25-20 UNC-2B X 31 DEEP
12 CONDUIT HOLE
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL5P2 SL5P52
Specification Units 036010 036261
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 458675 185255 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 31 IWGbull Maximum vacuum 313 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL5 Spiral SL5
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
0
15
30
45
60
75
90
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
0
15
30
45
60
75
90
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
AB
B
CX
W
R S
L
F
PU
M N O11
3 (2
869
6)
J
(4X) MTG HOLES028 DIA
KG
VZ
T
250 (6350)AA
Oslash40HOLE (4X)
175 (4445)35 (8890)
TEFC MODEL
D (R
EF)
538
(136
65)
E
Y
Oslash5
19 (1
318
3)
495 (1257)
495 (1257)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
CX
W
Oslash769 (19528)
R S
L
P (DIA INLET)F
U
M N O
J
(4X) MTG HOLES028 DIA
KG
VZ
H (TYP)
T253 (6431)
HOLES FOR ELECTRICAL CONNECTIONS
14-20 UNC-2B X 50 DP(4) MTG HOLES EQUALLYSPACED ON A 3625 DIA BC
14-20 UNC-2B X 50 DP(4) MTG HOLES
175 (4445)350 (8890)
STANDARD MODEL
D3
49 (8
875
)
123
(31
35)
E
Y
150 (3810)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
R
S
T
U
V
W
X
Y
Z
AA
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
197(50)
278(706)
726(1844)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
NC33AG58(XP)
NC33AE9(TEFC)
NC33A(STD)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
420(1067)
278(706)
1394(3541)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
352(894)
278(706)
1335(3391)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)713
(1811)
PartModel Number
NC33A2G NC33A3G NC33A33G NC33AE9 NC33AG58
Specification Units 037791 037792 037793 080114 080113
Phase - Frequency - Single-5060 Hz Single-5060 Hz Three-5060 Hz Single-5060 Hz Single-5060 Hz Voltage AC 115 220230 208-230 115230 115230 RPM on 5060 Hz - 29003500 29003500 29003500 29003500 29003500 Insulation Class - B B B F F Full - Load Amps Amps (A) 344384 147182 110118 6030 44 Locked Rotor Amps Amps (A) 825 40 50 21105 3819
Shipping Weight Lbs 18 18 18 28 30 Kg 82 82 82 127 136
Motor Enclosure - Standard Standard Standard TEFC XP
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
80
70
60
50
40
90
80
70
60
50
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
SOUN
D PO
WER
LEVE
L ndashdb
(re
10
Wat
ts)
2075
75150
150300
300600
6001200
12002400
24004800
480010000
OCTAVE BAND CENTER FREQUENCY Hz
-12
NC33
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Thermoset plastic blower housing with aluminum impellerbull Permanently seal ball bearings in motor - L10 bearing life 50000 hoursbull Quiet operation within OSHA standardsbull Shipping weight 18 lbs (82 kg) for standard model
28 lbs (127 kg) for TEFC model30 lbs (136 kg) for XP model
bull Designed for UL and CSAbull Automatic thermal overload protection on standard motor enclosures
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
LegendPressureSuction
LegendPressureSuction
NC33 NC33
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
G650
165
1
B
C
E042107
1021259
LF
I HA
J
D
(4) MTGHOLES
THREAD
THREAD
MODEL
DR404AQ58M
DR454V58
DR505AW58M
DR513V58
DR656K58X
A (INMM) B (INMM) C (INMM) D (INMM) E (INMM) F (INMM) G (INMM) H (INMM) I (INMM) J (INMM) K (INMM) L (INMM)
8932268 1012257
4751207
4751207 192488 6281595 1152921 12163089 30762 375953 12883722 5915 12913279
225572 7461895 15423917 15173853 4141052 551397 15123841 5915 15513939
4751207
10302616 11382891 192488 6981773 12553188 325826 4501143 10812746 5915 1445367
10302616 11702972 187475 7261844 13533437
13523434
14383653 356927 4501143 14383653 5915 150381
114229014751207 223566 8692207 14213609 1584013 372945 5501397 1374349 5915 14583703
492125 11422901 1283251
1303302
12-14 NPSM
T-BOX
GND LUG
P DIA
2- NPSC
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY
FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL
LENGTHS NOT SHOWN
INMM
PartModel Number
DR404AQ58M DR454V58M DR505AW58M DR513V58 DR656K58X
Specification Units 037778 080485 037935 038143 080603
Motor Enclosure - Shaft Mtl - SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS TEFC-CS Horsepower - 10 15 20 15 30 Voltage AC 115230 115230 115230 115230 115230 Phase - Frequency - Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 1575 15276 21105 15276 31155 Service Factor - 14 13 12 13 10 Maximum Blower Amps Amps (A) 84 1785 2613 1785 278139 Locked Rotor Amps Amps (A) 3216 8543 13668 8543 200100 Recommended NEMA Starter Size- 000 10 10 10 151
Shipping Weight Lbs 64 76 83 90 51 Kg 29 345 376 408 231
Recommended Number of Jets - 3-6 5-10 5-10 12-17 8-12
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
Notes- The blower should not be stoppedstarted more than four times an hour - Use of relief valve 515092 is required for all blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 56 58 74 69 or 88 IWGbull Standard motor 10 15 20 30 HP Spa Duty ODP
(threaded)bull
Class B rated thermal protectionbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull Variable frequency drive package
UL amp CSA approved motor with permanently sealed ball bearings and
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
DR404DR454DR505DR513DR656
LegendPressureSuction
DR404DR454DR505DR513DR656
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
100
200
0
100
200
0
100
200
0
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
PartModel Number
DR10RDNT SS10RDNT HS10RDNT
Specification Units 036594
Shaft Material - Carbon Steel Stainless Steel Hastelloy Speed Range - 1750-4500 1750-4500 1750-4500 Housing Cover Cover - Cast Iron Stainless Steel Hastelloy
Shipping Weight Lbs 400 500 600 Kg 1814 2268 2722
SS = Stainless Steel HS = Hastelloy
1 DR10RDNT not recommended for use with explosive gas due to material of construction
2
3
4
Maximum operating temperature Blower outlet air temperature should not exceed 260degC (air temperature rise plus inlet temperature)Contact factory for use above 260degC blower outlet air temperature
AMETEK will not be liable for blowers operated beyond factory specic RPM
All applications must be reviewed Contact application engineering for assistance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
bull Packaged on baseplate with V-belts or coupling guard amp motorbull High temperature Vitonreg sealsbull Krytoxreg grease high temperature bearings
PACKAGEMOTOR OPTIONSbull International voltage amp frequency (Hz)
bull Packing gland or double faced seal options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Variable frequency drive package
Note For accessories special high temperature models may be required
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
20
40
0
20
40
AIR T 100 ordmC
75 ordmC
50 ordmC
4500 RPM3500 RPM2500 RPM
1750 RPM
4500
3500
25001750
AIR T 100 ordm C
75 ordm C
50 ordm C
4500 RPM3500 RPM
2500 RPM
1750 RPM
4500
3500
25001750
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
Rev 204
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
MD101CB4 MODEL SHOWNTEFC MOTOR
MD101CC4 MODEL SHOWNXP MOTOR
Oslash9
8424
99
249
9
188478
478
169429
429
4121047
1047
1500381
6001524
1524
RESET BUTTONOslash 87 CONDUIT HOLE
22
350889
889
300
762
762
262
665
665
OUTLET INLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE71
71
Oslash9
84
188
169
8252096
412
1664216
600
LEADS FAR SIDE
350
300
262
OUTLETINLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE
75-14 NPT
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
ROTATION
ROTATION
PartModel Number
MD101CB4 MD101CC4
Specification Units 038014 038271
Motor Enclosure - Shaft Mtl - TEFC Explosion-proof Horsepower - 25 25 Phase - Frequency Voltage - Single-60 hz Single-60 hz Motor Nameplate Amps AC 115 115 Max Blower Amps Amps (A) 26 26 Locked Rotor Amps Amps (A) 22 22 Service Factor Amps (A) 64 72 Starter Size - 10 10 Thermal Protection - 00 00 XP Motor Class - Group - Class B - Automatic Manual Reset Class B - Automatic
- - I-D
Shipping Weight Lbs 40 40 Kg 181 181
F 21
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
FEATURESbull Hermetically designed seal-less blowerbull Continuous operationbull Manufactured in the USA
bull Maximum pressure 28 IWGbull Maximum vacuum 265 IWGbull Standard motor 025 HP TEFC or XPbull Disconnect motor without disassembling from piping
bull Permanently sealed ball bearings in housing and motorbull Quiet operation within OSHA standards
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
AIRSG = 10
NATURAL GASSG = 056
NATURAL GASSG = 056
AIRSG = 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 GVR313AK4H MODELS SHOWN
10502667
ROTA
TIO
N
375
953
14193604
113
8 (T
YP)
289
1
1 12 NPTF (2) PLACES (GVR313)
22559
4001016
IN OUT
68751746
421067
348688
224 49
124
5
65
165
1
BOTTOM VIEW
INMM
PartModel Number
GVR313AK4H GVR313AK58H GVR313AK72HA GVR313AK91H GVR313AE4HA
Specification Units 038584 081531 081470 081524 080274
Motor Enclosure - Shaft Mtl - Explosion-proof - CS Explosion proof - CS Explosion proof - CS ATEX - CS TEFC Horsepower - 05 05 05 075 05 Phase - Frequency Voltage - Single-60 hz Single-5060 Hz Three-60 Hz Three-50 Hz Single-60 Hz Motor Nameplate Amps AC 115 110220 230460 400 115 Max Blower Amps Amps (A) 94 8442 1407 14 74 Locked Rotor Amps Amps (A) 76 6834 1407 11 74 Service Factor Amps (A) 45 45 10251 9 47 Starter Size - 10 10 115 10 10 Thermal Protection - 0 0 00 0 0 XP Motor Class - Group - Class B - Automatic Class B - Automatic Class B - Automatic Thermistors Class B - Automatic
- I-D 1-D 1-D EExd IIB 1-D
Shipping Weight Lbs 39 39 39 45 39 Kg 177 177 177 204 177
1 115 voltage 1 phase motors are standard 230 volt motors available As an option a transformer could be used2 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors
or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
Rev 204
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
FEATURESbull Manufactured in the USA
bull Maximum pressure 45 IWG bull Maximum vacuum 408 IWGbull Standard motor 05 HP TEFCbull Anodized cast aluminum blower housing impeller amp cover
bull Quiet operation within OSHA standardbull ROHS gold irridite coatings on aluminum surfaces
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONS
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
GVR313
GVR313
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 24Customer Service Fax +1 2152561338 wwwametekdfscom
Accessories AMETEK Dynamic Fluid Solutions ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our accessories for regenerative blowers inlude
Filtration Accessories Measurement Accessories Noise Reduction Accessories Valves and Gauges
VFD Drives Air Knives
Blower Model Reference Key A = SPIRAL E = DRENCP656 6 633 S7 B= DRENCP068 083 101 202 F = DRENCP 757 808 858 S9 P9 (Inlet Only) C= DRENCP303 312 313 353 G= DRENCP833 S13 P13 (Inlet Only) D = DRENCP404 454 513 505 555 523 H = DRENCP909 979 1233 14 S15 P15 (Inlet Only)
Blower Connection Key NPTndash American National Standard Taper Pipe Thread (Male) NPSCndashAmerican National Standard Straight Pipe Thread for Coupling (Female) SO ndash Slip On (Smooth ndash No Threads)
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inlet Filter (Single Connection)
Inlet Filters protect the blower and the air distributionsystem from dust and other airborne particles andcontaminants Normally used in pressure systems
A
Oslash
B
C Oslash
SPECIFICATIONS HOUSING ndash Steel MEDIA ndash Polyester EFFICIENCY ndash 97-98 (8 to 10 micron particle size) FILTER ELEMENT ndash Replaceable (see filter elements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particle size) available
PartModel Number
Specification Units 477411 516466 515122 515123 515124 515125 515145 515151 516511
Filter Element - A B C D E E F G H H Ref Blower Model - 271078 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 200 SO 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 456 600 600 775 1000 1000 1000 1000 1600 mm 1158 1524 1524 1969 254 254 254 254 4064
Dimension B Inches 612 650 650 725 1225 1250 1300 1400 1500 mm 1554 1651 1651 1842 3112 3175 3302 3556 381
Dimension C Inches 200 100 15 200 200 250 300 400 600 mm 508 254 381 508 508 635 762 1016 1524
Z Media Filter PN - 517865 517866 517867 517868 517869 517870 517871 517872
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 11258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inline Filter (Dual Connection)
Inline Filters protect the blower from harmful dustand other particles that may be drawn into theblower through the air distribution systemNormally used in vacuum systems
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron particle size)FILTER ELEMENT ndash Replaceable (see filterelements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particlesize) available Feature 14 threaded tap for gauge connection on inlet and outlet
Inline lter PN 271200 is a straight through designInlet is directly opposite of outlet
D DIA
B
A
C DIA
PartModel Number
Specification Units 271200 516461 515254 515255 515256 516463 516465 517611
Filter Element - 271078 516434 516434 516435 516435 515135 515135 516515 Ref Blower Model - A B C D E F G H H Inlet Connection - 175 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M Outlet Connection - 200 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M
Dimension A Inches 525 725 700 800 800 1400 1400 1800 mm 1334 1842 1778 2032 2032 3556 3556 4572
Dimension B Inches 831 650 650 1025 1025 2650 2700 2800 mm 2111 1651 1651 2604 2604 6731 6858 7112
Dimension C Inches 200 100 150 200 250 300 400 600 mm 508 254 381 508 635 762 1016 1524
Dimension D Inches 175 100 150 200 250 300 400 600 mm 445 254 381 508 635 762 1016 1524
Z Media Filter PN - 517886 517887 517888 517889 517890 517891 517892
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Silencers (Single Connection)
FilterSilencers reduce noise levels whileensuring clean air is provided to the blower andthe air distribution system Normally used inpressure applications
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron size)FILTER ELEMENT ndash Replaceable (see filter elements)
A
Oslash
B
C
Oslash
PartModel Number
Specification Units 516487 516489 516491 516493 516495 516497 516499 516513
Filter Element - B C D E E F G H H Ref Blower Model - 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 600 600 1000 1000 1000 1000 1233 1600 mm 1524 1524 254 254 254 254 313 4064
Dimension B Inches 650 650 725 1225 1250 1250 1387 1500 mm 1651 1651 1842 3112 3175 3175 352 381
Z Media Filter PN - 517878 517879 517880 517881 517882 517883 517884 517885
Dimension C Inches 100 150 200 200 250 300 400 600 mm 131541012 131541266 13154152 131541774 131542028 131542282 131542536 13154279
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 31258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Element
All ROTRON Air Filters and FilterSilencers have replaceable filter elements The filter media is polyester designed for high efficiency over a wide spectrum of industrial applications See yumllter element cross reference table Filter elements supplied with foam pre-filter
Standard Replacement Filter Element Cross Reference Table
271200 271078 515158 515134 516489 515132477411 271078 515254 516434 516491 515133515122 515132 515255 516435 516493 515134
515123 515133 515256 516435 516495 515134515124 515134 516461 516434 516497 515134515125 515134 516463 515135 516499 515135
515145 515134 516465 515135 516511 516515515151 515135 516466 515132 516513 516515515157 515133 516487 515132 517611 516515
HT
For DR Blower Models
OslashID
OslashOD
Filter Filter FilterElement Element Element
PartModel Number
Specification Units 515132 515133 515134 515135 516434 516435 516515
Z Media Filter PN - 517873 517874 517875 517876 517893 517894 517877
Dimension ID Inches 300 363 35 475 256 350 800 mm 762 922 889 1207 65 889 2032
Dimension OD Inches 438 588 588 788 500 588 1175 mm 1113 1494 1494 2002 127 1494 2985
Area SqFt 475 475 950 963 475 875 963 SqM 0 0 1 1 0 1 1
Dimension HT Inches 15 23 45 83 20 45 190 mm 381 584 1143 2108 508 1143 4826
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 41258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
By separating and containing entrained liquidsROTRONrsquoStrade moisture separator helps protect our regenerative blowers and the end treatment systemfrom corrosion and mineralization damage Recommended for all soil vacuum extraction Applications
applications
PLASTIC ldquoPrdquo DESIGN METAL ldquoDrdquo DESIGN METAL ldquoBrdquo DESIGN
SPECIFICATIONSSEPARATION METHOD ndash High Effciency Cyclonic RELIEF VALVE MATERIAL ndash Brass amp Stainless SteelFLOAT MATERIAL ndash CopperFLOAT SWITCH ndash SPDT Explosion-proof
NEMA 7amp9 5 Amp max
(OPTIONAL)
VALVE
(OPTIONAL)
ODINLET
(PLUGGED) SWITCH(OPTIONAL)
G
D
H
H
(PLUGGED)
C
J
B
34NPT
CAPACITY(PER CHART)
EF
390
(OPT
ION
AL
LOW
SW
ITCH
)
SWITCH(OPTIONAL)
INLET
H
B
DJ
E
F
(OPTIONAL)
(PLUGGED)
B
VALVE
(OPTIONAL)
J
D
C
E F
G
VALVE
34NPT
INLETOD
FLOAT SWITCH
34 NPT
VACUUM RELIEF
VACUUM GAUGE
14 NPT FLOAT LEVEL 14 NPT
DRAIN
WATER LEVEL
DRAIN - 1 NPT INTERNAL THD
FLOAT LEVEL
OD
VACUUM GAUGE
14 NPT
VACUUM RELIEF
VACUUM GAUGE
VACUUM RELIEF
DRAIN
TMMOISTURE SEPARATOR
RAP AT ORI SO T U R E
EM
S
A
A
INSTALL FLOAT SW
INFO PACKET
MOISTURE SEPARATOR
TM CYCLONICACTIONCAUTIONFREEZING MAY CAUSE DAMAGEMOISTURE SEPARATORS USED IN TEMPERATURES BELOW 32oslashF (0oslashC)MUST BE PROPERLY WINTERIZED
A
T ORURE
G
OUTLETOUTLET
OUTLET
PartModel Number
MS200PS MS300PS MS350BS MS500BS MS600BS MS1000BS
Specification Units 038519 038520 038357 080660 080659 038914
Dimension A Inches mm
238 605
288 732
325 826
325 826
400 1016
600 1524
CFM Max CFM m3hr
200 340
300 510
350 595
500 850
600 1020
1000 1700
Dimension B Inches mm
2246 5705
2246 5705
2800 7112
2800 7112
2700 6858
3100 7874
Dimension C Inches mm
1600 4064
1600 4064
2300 5842
2300 5842
2300 5842
2700 6858
Dimension D Inches mm
325 826
325 826
400 1016
400 1016
400 1016
400 1016
Dimension E Inches mm
3105 7887
3105 7887
3725 9462
3737 9492
3737 9492
4732 12019
Dimension F Inches mm
3330 8458
3330 8458
3950 10033
5450 13843
5450 13843
5170 13132
Dimension H Inches mm
6 1524
600 1524
975 2477
975 2477
925 235
1000 254
Dimension G Inches mm
450 OD 1143
450 D 1143
450 OD 1143
663 ID 1684
663 ID 1684
862 OD 2189
Dimension J Inches mm
1325 3366
1325 3366
1750 4445
1750 4445
1750 4445
1988 505
Drain Internal Thd - 34 34 1 1 1 1
Shipping Weight Lbs Kg
42 191
42 191
82 372
95 431
96 435
150 68
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
404
ForDRENCP
BlowerModel
SelectorMoistureSeparator
Model
Liquid-holdingCapacity(gallons)
Inlet(OD)
Outlet
MaxVacuum
Allow(IHG)
454
MS200PS 7 238 12
45 OD
MS300PS 7 288
MS350BS
MS500BS 40325
MS600BS 40663 ID 22
MS1000BS
Pre
ssur
e D
rop
(IWG
)
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
1
2
3
4
5
6
Flow Rate (SCFM)
65 60 862 OD
505513523555633833656
6757808
909
8581233
97914
The moisture separator shall be designed for use in a soil vapor extraction system capable of continuous operation with a pressure drop of less than six inches of water at the rated ow of _____ SCFM The separator shall be capable of operation under various inlet conditions randing from a ne mist to slugs of water with high eciency
The moisture separator shall incorporate cyclonic separation to remove entrained water The separator must protect against an overow by fail safe mechanical means An electrical switch or contact(s) alone is not an acceptable means of protection against overow but is a good backup
The body of the moisture separator shall be constructed of heavy wall plastic or heavy gauge cold rolled steel The steel interior and exterior shall be epoxy (powder) coated to resist abrasion corrosion and chipping that might expose the surface The inlet shall be tangentially located and welded to the body The outlet port shall be constructed of PVC or cast aluminum alloy anged and sealed to the center of the top of the separator The separator shall incorporate a non-sparking copper oat ball and an adjustable relief valve to protect against overow and overheating the blower
The moisture separator must have a liquid capacity of _____ gallons The inlet shall be _____ inch OD slip-on type The outlet shall be _____ inch OD slip-on type
20 Moisture SeparatorTM Specications
21 Duty
22 Principle of Operation
23 Construction
24 Capacity and Dimension
25 Pressure Drop
MS2
00PS
MS3
00PS
MS3
50BS
MS5
00BS
MS6
00BS
MS1000
BS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
FEATURESbull Direct reading in SCFMbull Low pressure drop (2-4 typical) across
the flow meterbull Non-clogging low impedance air streambull Light weight aluminumbull No moving partsbull Large easy-to-read dialbull Accurate within 2 at standard conditionsbull Good repeatabilitybull Available in 2 3 and 4 sizesbull Factory conyumlgured for quick installationbull 048 Allen key supplied for gauge adjustment
OPTIONSbull Corrosion-resistant version with Chem-Tough
trade or in stainless steelbull FDA-approved Food Toughtrade surface conversion
BENEFITS
bull OPTIMIZE SYSTEM EFFICIENCY Measuring the correct air ˜ow canassist you in yumlne-tuning to yoursystemrsquos optimal efficiency
bull BALANCE MULTI-PIPING SYSTEMSWhen evacuating CFM from more than onepipe di˝erent run lengths or end systemimpedance can cause one pipe to handlemore CFM than the other With an accurateCFM reading piping can be balanced bybleeding air inout or by creating an extraimpedance
bull DETECT CHANNELING OR PLUGGINGFor systems in which channeling orplugging can occur a change in the CFMmeasured can help indicate the unseenchanges in your system
PartModel Number
FM20C030Q FM20C045Q FM20C065Q FM20C125Q FM20C175Q FM20C225Q
Specification Units 550599 550600 550601 550602 550603 550604
Flow Rate CFM 6-30 9-45 13-65 25-125 35-175 45-225 m3hr 10-50 15-77 22-111 43-213 60-300 77-383
Threads B - 2-115 2-115 2-115 2-115 2-115 2-115
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
PartModel Number
FM30C250Q FM30C350Q FM30C475Q FM40C450Q FM40C600Q FM40C850Q
Specification Units 550605 550606 550607 550608 550609 550610
Flow Rate CFM 50-250 70-350 95-475 90-450 120-600 170-850 m3hr 85-425 119-595 162-808 153-795 204-1020 289-1445
Threads B - 3-8 3-8 3-8 4-8 4-8 4-8
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
HOW IT WORKSHIGH TEMPERATURE PRESSURE CORRECTION
TYPICAL FLOW METER ARRANGEMENT
ROTRONrsquoS ˜ flow meter is a venturi style designAfter air enters the inlet the pressure ismeasured in the P1 tap The second tap P2measures the pressure at the throat Thedifferential between P1 and P2 registers across a special calibrated CFM gauge to provideaccurate readings The throat is then expandedback to the original size to keep pressure loss tounder2-4 IWG
SCFM 1SCFM 2 =
147 x 530Pf2 Tf2 + 460radic( ) ( )
Pf 2 = Absolute Pressure inPSIA Tf2 = Temperature in degF
bull Use on inlet to limit need to correct for highpressure or elevated outlet temperature
bull Standard model limits = 140degF and 30 PSIG
TYPICAL GAUGE FACE
REGENERATIVE BLOWER GROUP
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
FLOW DIRECTION
375
375
20
287DIA
556
175
35REGENERATIVE BLOWER GROUP
C
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
B
OslashF
TMMOISTURE SEPARATOR
R A PATORIS OTURE
EM
S
BLOWER
INLET FLOWMETER SYSTEM UNDER VACUUM
SYSTEM PIPING
P RE S SUR E 3 0
P S I GXAM
014070
210 280
350
MINIHELIC II
AMETEKROTRON TIPTECHNICAL amp INDUSTRIAL PRODUCTS
IN OUT
P1 P2
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Digital Flowmeter
316
187
3583
3780
1 2 3 4
2596
275
48114
350 100
Oslash16 (2X)MOUNT HOLES
OUT
LOW
HIGH
-COM
+EXC
189 169
551
Remote air flow rate monitoring and system automation control can now be achieved through the use of 4-20 mA output signalsOur 4-20 mA analog outputs are proportional to system flow rates and can be used with PLC controlled operations to monitorsystem performance Those same outputs provide digital displays for direct readings in SCFM when paired with our LCD DigitalReadout option Combined with our Variable Frequency Drives you can now achieve a completely automated system capable ofadjusting blower performance to meet changing system demands Maintaining your system at peak performance gives yourcompany the competitive edge needed in todayrsquos marketplace
FM20S030Q FM20S045Q FM20S065Q FM20S125Q FM20S175Q FM20S225Q FM30S250Q FM30S350Q FM30S475Q FM40S450Q FM40S600Q FM40S850Q 550838 550839 550840 550841 550842 550843 550844 550845 550846 550847 550848 550849
LCD DISPLAYFM20L030Q FM20L045Q FM20L065Q FM20L125Q FM20L175Q FM20L225Q FM30L250Q FM30L350Q FM30L475Q FM40L450Q FM40L600Q FM40L850Q 550860 550861 550862 550863 550864 550865 550866 550867 550868 550869 550870 550871
DIFFERENTIAL PRESSURE TRANSMITTER 4-20 mA signal output control signals provide flow rate monitoring capabilities from remote locations NEMA 1R-raintight enclosure orotects the integrated DC power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter Weight 3 lbs Signal Output 4-20 mA DC1
HiLo pressure fittings feature snap lock action to unsure trouble-free connections2
System includes standard flowmeter for on-site readings and troubleshooting Operating temperature 0oF to 150oF Drawing available
LCD DIGITAL READOUT OPTIONS Factory configured to display direct readings in SCFM to a remote location up to 50 from signal output1 NEMA 4 IP65 enclosure ready for panel mount instlation power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter installation Power input 120 VAC 5060Hz AC Field configurable to 240VAC Display 5 digit 7 segment 5 high LED w33Hz update rate Operating temperature 10oC to 40oC Weight 1lb 14oz
Drawing available Note 1 4-20 mA output control wiring to be customer supplies Shielded 2 conductor cables 22 AWG is recommemeded for runs up to 100 For longer runs contact factory
Note 2 Use 516 OD stiff wall tubing-connect Lo on flowmeter to Lo on 4-20 mA enclosure Hi on flowmeter to Hi on 4-20 mA enclosure Tubing must be equal in length (Maximum length is 1o feet)
DIFFERENTIAL PRESSURE TRANSMITTER
USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 9Customer Service Fax +1 2152561338 wwwametekdfscom
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
____
Accessories
Noise Reduction - Sound Attenuating Enclosure
Frameless sound attenuating enclosures are a proven way to reduce regeenrative blower mechanical noise when additional mufflers are just not enough Additional enclosure options are available
FEATURESExcellent noise reduction (~10DbA)Resistance to elements and aesthetic appearanceCompact size for ease of installationEasy access for routine maintenance (removable foor and sidewalls)
SPECIFICATIONS Roof floor and walls galvanized 16 ga carbon steel sheet metal Louvers andor hood Riveted aluminum Hardware Chrome plated aluminum handles with stainless steel fastners Latches Over center glvanized with adjustable tension and padlock eye Sound attenuating material 2 rigid polyester foam with mylar facing (rated UL-94) Exterior finish Polyurethane enamel
3000
5000
4600
LIFTING HOLE(PLUGGED)TWO (2) PER SIDE(TOTAL 4)
950
950
END SECTION
END SECTION3100 CLEAR
1500
18 FANASSEMBLY
200 200
2600 CLEAR
Enclosure ventilation 13 HP 230460V 3-phase or 1-phase 5060Hz fan TEFC or XP motors Fan Guard Nickel plated wire type
PartModel Number
SAE30W72F SAE36W72F
Specification Units 552904 552905
Width Inches 30 36 mm 762 9144
Blower Size - 656 707 757 808 858 909 979 P9 S9 14 P13 S13 P15 S15
Height Inches 46 52 mm 11684 13208
Length Inches 50 60 mm 1270 1524
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - InletOutlet Muffler (Single Connection)
Muers lower blower noise in areas where reduced sound levels are required
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
D
C
B
A
PartModel Number
Specification Units 523627 523626 523625 523624 523623 523622
Ref Blower Model - B C D E E E Inlet Connection - 10 NPT Male 125 NPT Male 150 NPT Male 200 NPT Male 200 NPSC Female 200 NPT Male
Dimension A Inches 400 400 400 400 400 400 mm 1016 1016 1016 1016 1016 1016
Dimension B Inches 1093 1093 1093 1093 1093 1575 mm 2776 2776 2776 2776 2776 4001
Dimension C Inches 1398 1407 1457 1216 1243 1695 mm 3551 3574 3701 3089 3157 4305
Dimension D Inches 100 125 150 200 200 200 mm 254 318 381 508 508 508
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - Inline Muffler (Dual Connection)
Inline Muers are utilized for noise reduction inapplications where piping systems are connected directlyto both ends of the muer Muer may be used on inletor outlet of blower
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
C
B
A OUTLETCONNECTION
INLETCONNECTION
PartModel Number
Specification Units 550888 522948 529900 551377 515185 511569 515210 551565 516264
Ref Blower Model - D E E E F G G G H Inlet Connection - 15 NPT-M 20 NPT-M 20 NPSC-F 20 NPT-M 25 NPT-M 30 NPT-M 40 NPT-M 40 NPT-M 40 NPT-M Outlet Connection - 20 NPT-F 20 NPSC-F 20 NPSC-F 20 NPT-M 25 NPT-F 30 NPT-F 40 NPT-F 40 NPT-M 40 NPT-F
Dimension A Inches 400 400 438 400 612 700 1000 1000 800 mm 1016 1016 1113 1016 1554 1778 254 254 2032
Dimension B Inches 775 1575 1575 1575 1500 1800 2400 2400 2200 mm 1969 4001 4001 4001 381 4572 6096 6096 5588
Dimension C Inches 155 1845 1845 1815 1900 2225 3000 3000 2775 mm 3937 4686 4686 461 4826 5652 762 762 7049
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Relief Valve - Mechanical
Part Model Number
Specification Units 551026 551027 523230
Ref Blower Model - B C D D E F A B C D E F
Range in H2O mbar
20-180 498-4484
415-263 1034-6551
35-90 872-2242
Connection - 1 12 2 Description - Mechanical Mechanical
2 Mechanical Vacuum Only
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS G 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Pressure Regulating Diaphram Valve
PRESSURE RELIEF B is the system port and A is the vent or atmospheric port
VACUUM RELIEF A is the system port and B is the vent or atmospheric port For vacuum mode customer must remove snap ring and screen
NOTE Replace cap after adjusting setting Valve will not operate with cap removed Differential adjustment screw is under the cap
Fig 1 Fig 2
NOTE Blower Model P13 requires two 515093 relief valves
The PRD Valve is installed to prevent excessivesystem pressure or vacuum that could result fromline restrictions Valves should be installed at theblower outlet (downstream) in pressure systemsand at blower inlet (upstream) in vacuum systemsThese valves are suitable for air natural gaspropane and other non-corrosive service
Note PRD valves are not factory preset but areeasily field adjustable
SPECIFICATIONSVALVE BODY ndash Aluminum (1) CastIron (2) VALVE SPRING ndash SteelDIAPHRAGM ndash Nitrile
D
C
DIFFERENTIALADJUSTMENTSCREW
A
BGAUGEPORT
SEENOTE
GAUGEPORT
A
B
D
C
PartModel Number
Specification Units 515092 529612 529857 529858 551130 515093 529859 550246 550247
Range in H2O 27-125 110-415 277-554 7-18 14-62 48-194 110-277 97-197 97-194 mbar 673-3114 274-10338 690-1380 174-448 349-1544 1196-4833 274-690 2416-4907 2416-4833
Description - Fig 1 Fig 1 Fig 1 Fig 2 Fig 2 Fig 2 Fig 2 Pressure Vacuum Ref Blower Model - B C D E B C D E B C D E F G F G F G F G H H Inlet Connection - 1 1 1 2 2 2 2 25 25 Outlet Connection - 1 1 1 2 2 2 2 25 25
Dimension A Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension B Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension C Inches 412 412 412 712 712 712 712 619 619 mm 1046 1046 1046 1808 1808 1808 1808 1572 1572
Dimension D Inches 870 870 870 900 900 900 900 765 765 mm 221 221 221 2286 2286 2286 2286 1943 1943
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Gauges
ROTRON has a variety of gauges for pressurevacuum and temperature measurements invarious ranges These gauges are reliable andrugged
SPECIFICATIONS
Pressure Vacuum TemperatureCASE ndash Drawn Steel Finished CASE ndash Steel
LENS ndash GlassACCURACYndash 1
in Black EnamelDIAPHRAGM ndashBronze LENS ndash ClearPlastic ACCURACYndash2WEIGHT ndash 12 lbCONNECTION ndash 14NPT FACE ndash 2 12 dia
WEIGHT ndash 14 lbCONNECTION ndash 12NPT FACE ndash 3 Dial
Pressure Vacuum
Temperature
200
180
160
140
120100
80
60
40
20
100
50
150
200 250
350
400
300
degF
degC
10
0
1
2
3
4
5
6
PRESSURE
0
2040
60
80 100
120140
160
P S INCHE S OF WAT E RI
25 plusmn03Oslash 318 plusmn12
250 plusmn06
338 plusmn12
12 NPT CONNECTION
PartModel Number
Specification Units 551376 271949 529428 271950 551368
Range - Pressure Pressure Vacuum Vacuum Temperature Description - 0-60 IWG 0-160 IWG 0-60 IWG 0-160 IWG 0-200 Deg C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Variable Frequency Drive
A Variable Frequency Drive (VFD) is an adjustable speed AC motor control designed to speed the blower RPM up or down Our VFDs are designed to minimize losses and deliver increased efficiency low maintenance and the long life expected from the ROTRON product line
FEATURESbull
ncy by controlling motor RPMsbull Accepts 3Oslash or 1Oslash inputs to drive 3Oslash motor blower
assembliesbull Accepts 4-20 mA 0-5 VDC or 0-10 VDC inputs forsystem automation control and intregation
bull Provides dynamic breaking capabilitiesbull Replaces motor starter functionbull Digital readout in either Hz or RPMsbull Keypad enclosure (NEMA4X-Indoor) vsn be
mounted up to 100 from controller with cable assembly option
SYSTEM REQUIREMENTSbull In cases where the distance between the controller
and motor exceed 50 the use of a line reactor on load side is needed
bull XP motors must be UL listteedd for use with a Variable Frequency Drive
VARIABLE FREQUENCY DRIVE SELECTIONThere are some common guidelines in sizing a VFD for use on a AMETEK ROTRON blowers such as the allowable speed(table 1) for a given motor type To determine the required RPM to achieve a desired flow and pressure form a specific bloewr turn to the blower performance at variable speeds in section E of this catalog The required RPM must fall within the allowable rate of the motor being used
Motor Allowable Turndown Allowable Speedup
Standard 3600 RPM to 1800 RPM mdash3600 RPM to 900 RPM mdash
Inverter Motor 3600 RPM to 360 RPM 3600 RPM to 7200 RPM
Turndown of 101 is not typically done with regenerative blower designsFor all applications above 3600 RPM contact your Field Sales Engineer for proper horsepower sizing
Table 1
Specification
Model Number Part Number Description
IV101AE58 551529 1151 Up to 05 HP DR068-DR303 IV102AE58 551530 2301 Up to 05 HP DR068-DR303 IV101AL58 551531 1151 075 to 10 HP DR353-DR404 IV102AL58 551532 2301 or 3 075 to 10 HP DR353-DR404 IV103AL72 551533 4603 075 to 10 HP DR353-DR404 IV102AS58 551534 2301 or 3 15 to 20 HP DR454-DR505 IV103AS72 551535 4603 15 to 2 HP DR454-DR505 IV102K58 551536 2301 or 3 25 to 3 HP DR505-DR555 IV103K72 551537 4603 25 to 30 HP DR505-DR555 2301 IV102D58 551538 or 3 35 to 5 HP DR555-DR808D 4603 IV103D72 551539 35 to 5 HP DR555 to DR808D 2303 55
IV152AY58 551540 to 75 HP DR808-DR858 4603 55 to 75 IV152AY72 551541 DR808 ndash DR858 IV152BB58 551542 2303 8 to 10 HP DR858-DR909 IV153BB72 551543 4603 8 to 10 HP DR858-DR909 IV152BC58 551544 2303 105 to 15 HP DR909 IV153BC72 551545 4603 105 to 15 HP DR909 IV152BH58 551546 2303 155 to 20 HP DR9 DR14BH IV153BH72 551547 4603 155 to 20 HP DR9 DR14BH IV152BP58 551548 2303 205 to 30 HP DR13 DR14 IV153BP72 551549 4603 205 to 30 HP DR13 DR14 IV152BQ58 551550 2303 305 to 40 HP DR15 IV153BQ72 551551 4603 305 to 40 HP DR15 IV153ED72 551552 4603 505 to 60 HP DR15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
SINGLE-ENDED SIDE VIEW DOUBLE-ENDED SIDE VIEW
Air knives 30 and smallerMOUNTING VIEW
CAPPED END VIEW
CL CL25-8 NPT(TYP)
CL CL25-8 NPT(TYP)
GAP SETTINGRAIL(REF)
CL
PER MODEL
CL CL
25-20 UNC THRU
25-20 UNC X 75 LG
315 TYP
315TYP
L
458
458
22
22
075
175
10 STYP
L
PartModel Number
AK06S060 AK12S060 AK18S060 AK24S060 AK30S060 AK36S060 AK42S060 AK48S060 AK54S060 AK60S060
Specification Units 523489 552955 522949 553000 522950 523492 523493 523494 523495 523496
Length (L) Inches 930 1530 2130 2730 3330 4230 4830 5430 6030 6630 mm 2362 3886 541 6934 8458 10744 12268 13792 15316 1684
Slot Length Inches 6 12 18 24 30 36 42 48 54 60 mm 1524 3048 4572 6096 762 9144 10668 12192 13716 1524
Dimension S Inches 400 1000 1600 2200 2800 1700 2000 2300 2600 2900 mm 1016 254 4064 5588 7112 4318 508 5842 6604 7366
The ROTRON air knife is located at a strategicpoint in your assembly line conveyor beltarea Air ows from the blower into the airknife where a sheet of air is directed outthrough a proprietary linear nozzle designonto assembly line parts The opening canbe altered to adjust the air-ow rate thusvarying blow-o velocity to meet yourapplication requirements
Air KnivesAn Oil-free Blowing and Drying SystemCustom-t for Your Application
FEATURESbull Lightweight aluminum plenum and rail steel end cap
and cast-iron NPT angesbull Engineered extruded design to achieve 95 eciencybull Adjustable slot (pre-set at 0060) to control velocity
from 5000-35000 fpmbull Custom cut lengths to t system restraintsbull Oil-free and lower cost alternative to compressed air for
blow-o solution blow-back and drying applications
OPTIONSbull Chemical resistant designs utilizing Chem-Tough TM
chemically resistant surface conversion stainless steel hardware and nickel plated end caps and anges
bull Food processing grade designs utilizing Food-Tough TM
sanitary treatment surface conversion stainless steel hardware and nickel plated end caps and anges
bull Deionizers for sterile environments availablebull Mirror image single-ended models for above and below
conveyor operation
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800SCFM
Air Velocity
Precision Cleaning Air Knife and Blower Selection Chart
DR656
DR757
DR808 DR858
DR909
DRP9
DR979
DRP13
DR14
DRP15
6 knife
12 knife
18 knife
24 knife 30
knife 36 knife
42 knife
48 knife 54
knife60
knife
40000 FPM
35000 FPM
30000 FPM
25000 FPM
20000 FPM
15000 FPM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
air
These unique solenoid actuated diverter valves automatically change air piping from pressure to suction greatly enhancing blower versatility and productivity This valve is effective in blower applications that require frequent switching frompressure to suction and vice-versa They are costeffective as applications normally requiring twoblowers andor intricate piping systems may be accomplished with one blowerDiverter valves may be purchased as blowervalve assemblies or as separate stand-alone valve assemblies for use in other switched air applications
SPECIFICATIONSbull Aluminum body and spool assemblybull 303 stainless steel shaftbull 115 V-60 Hz solenoid valve
OPTIONSbull Corrosion resistant surface treatmentsbull International voltage and frequency (Hz)bull Application specific designs
DR 505 BLOWER WITH DIVERTER VALVEThe principle behind ROTRONrsquos diverter valve system is asimple one Some applications such as vacuum part pick-up airtables and pneumatic tube systems require both vacuum andpressure in their equipmentrsquos operation but not simultaneouslyThey eliminate the need for two sep-arate blowers andelaborate valving system or cyclingreversing a spinningblower impeller ROTRONrsquos diverter valve changes the airpassageways By utilizing the side vent ports for incoming oroutgoing air the equipmentpiping side of the valve changesfrom vacuum to pressure and back again by a signal sent to thesolenoid coil
PartModel Number
Specification Units 515554 037435 037482
Description - DR404 DR454 DR505 DR6 DR808 DR858 DR6 DR808 DR858 Ref Blower Model - Small Large Large Piping Flange - Threads Threads Threads Blower Flange - Face Threads Face
Dimension A Inches 765 925 925 mm 1943 235 235
Dimension B Inches 1422 2339 2339 mm 3612 5941 5941
Dimension C Inches 714 1093 1093 mm 1814 2776 2776
Dimension D Inches 250 355 355 mm 635 902 902
Dimension E Inches 500 710 710 mm 127 1803 1803
Dimension F Inches 150 250 250 mm 381 635 635
Dimension G Inches 150 250 250 mm 381 635 635
Consult factory for proper selection and application
SOLENOID
ENERGIZED POSITIONSUCTION AIR PATH
SOLENOID
DE-ENERGIZED POSITIONPRESSURE AIR PATH
A
D
BF
C
EG
EQUIPMENTPIPING SIDE ISO VALVE DRAWING
BLOWER SIDE
WORKINGPART
SUCTION PRESSURE
BlowerBlower
IN OUT IN OUT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
ROTRON RELEASED BLOWERS WITH DIVERTER VALVE MOUNTED Model Part No Mounted Components Diverter Valve Manifold
DR353BR58MV 080757DR404AL72MV 037749 517077DR404AL58MV 037715 DR454R72V 037605 515554
529397DR454R58V 037122DR505AS72MV 037709
517459DR505AS58MV 037554
037482 DR808AY72WV 080084
550667DR858BB72WV 080085
DIVERTER VALVE MANIFOLD
bull Models listed below include diverter valve and manifold
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Pressure amp Vacuum Arrangements
Pressure or vacuum guages should be located in the delivery line oriented as shown Assure that the guage is approxi-mately three pipe diameters from the blower delivery ange and that the relief valve is located at the same spacing from the guage 90deg elbows should be located at least ve pipe diameters from the blower delivery ange Elbows taps tees valves or other restrictions to air ow should not be located between the blower delivery ange and accessories described above
Failure to observe these precautions can result in false readings of guages and failure of the relief mechanism to protect the blower from overload
In order to avoid overheating or distortion of PVC pipe the rst ve to eight feet from the blower delivery ange on pressure systems should be metal
Typical Pressure System
Typical Vacuum System
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Motor Options
ROTRON strives to provide the most complete variety of desired options on our products including on our motors By using motor vendors of high quality and versatility we can provide motor features from multiple released designs to meet your needs (ie a Chem Processing Inverter Duty Explosion-proof motor with space heaters and drains wound for 380 V-50 Hzservice)
Design Consistency
ROTRON motors are engineered for us to integrally mount with our blower and maximize blower performance Our vendors are qualied by ROTRON (per motor part number) to ensure the blowersrsquo mechanical and electrical needs merge with your required features The basic motor requirements on our DRENCPHiE products include
bull NEMA approved
bull CE conformity (non-XP models)
bull UL amp CSA approved with symbol and file on nameplate
bull C-face mount
bull Permanently sealed bearings
bull Shaft end play run out and perpendicularity requirements above NEMA standards
bull Dual voltage and dual frequency (some models not feasible) to maximize use worldwide
bull Single Shafted Totally Enclosed Fan Cooled (TEFC) and Explosion-proof (XP) models
bull Double Shafted Open Drip Proof (ODP) models with dual internal fans for circulation
bull Class I Group D minimum on explosion-proof motors many are Class I Group D Class II F amp G
bull Commercial Spa (SPA-ODP) motors with automatic thermaloverload protection and industry specied terminal strip
Standard Motor Variations
Chemical Processing (CP) features are added to TEFC XP or HiE designs for corrosive gas service Marine Duty service and sanitary (foodpharmaceutical) service
bull 303 stainless steel shaft
bull Cast iron and steel frame epoxy painted or zinc plated
bull Zinc plated hardware
bull Stainless steel nameplate
bull Non-hygroscopic insulation double dipped and baked stator
bull Epoxy coating on rotor
bull Gaskets and joint sealers on all metal-to-metal surfaces
bull Oversized conduit box
High Efficiency (HiE) features are added to TEFC ODP XP or CP motors for maximum motor eciency and life ROTRON HiE motors carry extra phase-to-phase protection for use withinverters between a 1750-3500 RPM range
Inverter Duty features are added to TEFC ODP XP or CP for use with InvertersVariable Speed Drive Controllers A wide range of RPM can be handled and should be specified at time of quote For best compatibility an inverter should be matched to the motor manufacturers design
Project Specic Motor Variations
There are no limits to the options you can select or request for your product Routine motor options include
bull International voltage amp frequency (Hz)
bull Different shaft material
bull Oversized andor Nema 4 intent T-box
bull Space heaters
bull Drains
bull Regreasable bearings
bull Tropicalized windings
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Typical Sealing Options
Lo-Leaktrade LIP SEAL Option
The Lo-LeaktradeLip Seal option is available to control gas leakage for all DR models and is standard on all EN and CP models Features include Lip seals to prevent leakage at the motor shaft RTV sealingcompound is used to cut o all leakage paths at the blowerrsquos metal-to-metal surfaces Castings are vacuum impregnated to prevent leakage through castings Estimate leakage rate = 25 ccmin or less
Double Face Carbon Seal Option
For further minimization of gas leakage on all DR EN and CP models a pair of face seals work against each other on opposite sides of a common mating ring to eectively reduce gas leakageat the motor shaft The face shields are continually lubricated from a reservoir to prolong seal life The seal is completed by installing the blower to motor bolts with O-rings and sealingthe covers to the housing with an RTV sealing compound O-rings are also placed between the pipe anges and the manifold All castings are vacuum impregnatedEstimate leakage rate = 05 ccmin or less
Hermetically Sealed Spiral Containment Option
The containment option utilizes a series of O-rings to control gas leakage in Spiral blower models The O-rings are placed at critical locations on the blowerrsquos housing and covers to contain gas leakage
Hermetically Sealed Mag Drive Option
On DR EN and CP 101 units a magnet drive option has been an alternative for complete gas containmentO-rings are used throughout the product and magnets attached to the motor shaft spin magnets inside the blower without shaft penetration Estimated leakage rate = 0001 ccmi
Nitrogen Purge Blanket Option
The nitrogen purge option is a carrier designed to accept a nitrogen line which will purge the space outside the shaft hole Purges can be designed to bleed the nitrogen into the process called a blanket or the carrier can have a second tap to carry away the leaking contaminants
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chem-Toughtrade Chemical Resistance
To stand up in corrosive and hazardous environments chemical processing blowers have to be tough Thatrsquos why Ametek ROTRON routinely applies Chem-Toughtrade ROTRONrsquoS own engineered and proprietary process whenever it builds blowers for handling chemical (vapor) streams Chem-Toughtrade combines the advantages of aluminum oxide ceramic and selected uorocarbons to give ROTRON blowers unheard-of levels of chemical resistance hardness abrasion resistance permanent lubricity and more
Chem-Toughtrade Brings You the Rotron Advantage
Through this unique proprietary process Chem-Toughtrade gives ROTRON blowers these advantages
bull Outstanding Chemical ResistanceTime after time Chem-Toughtrade nishing shows extremely high resistance to most common chemicals as well as dramatically improved corrosion resistance over regular hard anodizing Chem-Toughtrade allows aluminum to achieve equivalent corrosion resistance as teonreg 90-day immersion in acid or alkaline solution (pH 40-85) has no eect neither does prolonged exposure to salt water Far exceeds military specication requirements for salt spray
bull Abrasion Resistance Equivalent to Steel Excellent for smooth surfaces Chem-Toughtrade surfaceconversion provides higher wear resistance than eithercase-hardened steel or hard-chrome plate Rub any other metal against the Chem-Toughtrade nish and the metal will show nothing but the slightest wear Chem-Toughtrade provides a perfect bond to the parent metal
bull Increased HardnessWith an equivalent hardness of Rc 40-60 Chem-Toughtrade is approximately le-hard ndash the hardness of nitrated steel Because the Chem-Toughtrade surface becomes an integral part of the metal it simply cannot peel or chip ndash neither can it bescratched aked or nicked under ordinary conditions
bull Permanent Dry LubricityBy infusing polymers into aluminum Chem-Toughtrade gives the resulting surface a high degree of permanent lubricity and resistance to moisture The polymers also level o surface asperities signicantly reducing surface tension The result blowers converted with Chem-Toughtrade have a longer life operate more eciently and call for less maintenance
bull Other Proprietary ProcessesFood-Toughtrade uses the same unique process as Chem-Toughtrade and is designed for the food processing medical andpharmaceutical markets Food-Toughtrade has USDA approval and meets FDA guidelines
Chem-Toughtrade at Work
Chem-Toughtrade employs the advantages of anodizing hardcoat plating low-friction polymers and dry lubricants to become an integral part of the blowerrsquos molecular structure
Specically Chem-Toughtrade rst converts the aluminum surface to aluminum oxide forming a new ceramic-like surface The water in the ceramic is replaced with Teonreg adding a multi-functional dimension to the surface in the process the aluminum crystals expand and form anchor crystals that remain hygroscopic for a short time Then under controlled conditions particles of the specied polymer are infused to interlock with these anchor crystals The new surface extends 5 mil above and below the original aluminum surface ndash and forms a permanent molecular bond with the metal
The result a plasticceramic surface thatrsquos harder than steel is continuously lubricating and resists damage from chemicals like no other The kind of protection you need for your chemical processing blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Acetaldehyde B C A A A A AAcetate Solv B B A A A B A B Acetic Acid B D C A B A B AAcetic Anhydride B B D A B A A B AAcetone A A A A A A A B AAcetylene A A A A A A A Acrylonitrile B C A A C BAlcohols
Amyl C C C A A A A ABENZYL B A A AButyl B C C A A A A ADiacetone A A A A AEthyl B A A A A A AHexyl A A A A AIsobutyl B A A A AIsopropyl B C A A A AMethyl B A A A A A A AOctyl A A A A APropyl A A A A A A
Aluminum Chloride 20 B D A D C D AAluminum Chloride D D B A C D C AAluminum Hydroxide A D A A A A A Alum Potassium
Sulfate (Alum) 10 A D A A A BAlum Potassium
Sulfate (Alum) 100 B A A D A B BAluminum Sulfate A D A A C C A AAmines A A B A A A A AAmmonia 10 A A AAmmonia Anhydrous B D B A A B A A AAmmonia Liquids D A A A A A A BAmmonia Nitrate C A A A A Ammonium Biuoride D C A BAmmonium Carbonate C C B A B A A A BAmmonium Chloride C D D A C A C A AAmmonium Hydroxide C A C A A A A A AAmmonium Nitrate B A D A A A A A AAmmonium Persulfate C D A A A A A AAmmonium Phosphate Dibasic A A A AB D A BAmmonium Phosphate Monobasic A A A AB A A Ammonium Phosphate Tribasic A A A AB C D A BAmmonium Sulfate B C C A C A B A AAmyl-Acetate B C A B A A C AAmyl Alcohol B A A A A AAmyl Chloride D A A C B AAniline C C A B A A A BAnti-Freeze A B C A A A AAntimony Trichloride D A D D AAromatic Hydrocarbons A A A A Arsenic Acid D D D A B A A
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Barium Carbonate B B B A B A A A ABarium Chloride D D C A C A A A ABarium Hydroxide D C C A B C A A BBarium Sulfate D C C A B A A A ABarium Sulde D C C A B A A Benzaldehyde B B A A A A A ABenzene B B C A B A A A BBenzoic Acid B D A B A A A ABenzol B A A A ABorax (Sodium Borate) C A C A A A A ABoric Acid B D A B A A A ABromine (Wet) D D D A D D D D AButadiene A C C A A A A Butane A C C A A A A Butanol A A A A AButylene A A A A A A Butyl Acetate A A A C AButyric Acid B D A B B A A ACalcium Bisulfate D D A C D A Calcium Bisulde C A B ACalcium Bisulte C A D A ACalcium Carbonate C D A B A A A ACalcium Chloride C C A C A D C ACalcium Hydroxide C A B A A ACalcium Hypochlorite C D A D A C C BCalcium Sulfate B A B A A A BCarbon Bisulde A B B A A A Carbon Dioxide (Wet) C C A A A ACarbon Disulde C B C A B A Carbon Monoxide A A A Carbon Tetrachloride C C D A B C B A ACarbonated Water A D B A A A Carbonic Acid A D A B A B A AChloracetic Acid C D A D D D D AChlorinated Glue D D A A
D C A D D D AChlorine Anhydrous LiquidChlorine (Dry) D A A B A A AChlorine Water D D A D D BChlorobenzene (Mono) B B C A A A A AChloroform D D C A A A A A AChlorosulfonic Acid D D A D D D BChlorox (Bleach) C D C A A A AChromic Acid 5 C D A A B AChromic Acid 50 C D A C B B ACitric Acid C D A A A A ACitric Oils C A A Copper Chloride D D A C D D B ACopper Cyanide D D A A A A ACopper Floborate D D A D D BCopper Nitrate D A B A A B A
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Chemical Resistance Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Copper Sulfate (5 Solution) A A A AD D A AABsloserCBAABACdicA cilyserCAAAenaxeholcyCAAAAstnegreteDAAAAAAleuFleseiDAAAAenimalyhteiDAAB
A BseyD
Epsom Salts (Magnesium Sulfate) A A A BAAAenahtE
E the Ar B A A A A BBAAACBetatecA lyhtE
ADCBC C C A A A BD C A A A BA B C A A A AA A A
edirolhC lyhtE A A A BEthylene ChlorideEthylene DichlorideEthylene GlycolEthylene Oxide
AAAADBsdicA yttaFBDDDADDedirolhC cirreF
Fer ric Nit rat De A A A A AAACAADD
D D A D D BD D D A B A C B
etafluS cirreFFerrous ChlorideFerrous Sulfate
ADDDCDDDeniroulFBBADDdicA cicilisoulFBAAAAADAedyhedlamroF
CADDDdicA cimroF A B B AAAABCB
B A D 11 noerF
Freon 12 (Wet)AB22 noerFAB311 noerFABFT noerFAAAAABCAsliO leuFAAAAAAniseR naruFBAAAAAAlarufruFAAABADDAdicA cillaG
AAAAAenilosaG A A A AAABBAenirecylG A A A A
AAAABAenatpeHAAAAABA
A A A A A A A A A A A D D D A D D D D AD D A D C A AD D A D D D BD D A D D D BD D A D D CA C A A A A C AD D A D D D BD D A C D C
enaxeHHydraulic Oils (Petroleum)Hydraulic Oils (Synthetic)Hydrobromic AcidHydrochloric Acid (Dry Gas)Hydrochloric Acid (20)Hydrochloric Acid (37)Hydrochloric Acid 100Hydrocyanic AcidHydrouoric Acid (20)Hydrouoric Acid (75)
Hydrouoric Acid 100 D D D A D D D BD D A D D BHydrouosilicic Acid (20)
Hydrouosilicic Acid C A D D CHydrogen Gas A B B A A A A Hydrogen Peroxide 10 A D A C C AHydrogen Peroxide A D D A A B A AHydrogen Sulde
Aqueous Solution C D A A A C AHydrogen Sulde (Dry) D B B A A C A AHydroxyacetic Acid (70) D Ink C D D A A A Iodine D D A D D D BIodoform A C B A B D A Isotane A Isopropyl Acetate C B Isopropyl Ether A A A A A Jet Fuel (JP3 JP4 JP5) A A A A A A A Kerosene A A B A A A A A AKetones B A A A A A A ALacquers A C C A A A Lactic Acid C D D A A A B C ALead Acetate D D A B A A ALubricants A A A A AMagnesium Chloride D D C A B B B A AMagnesium Hydroxide D B B A A A A AMagnesium Sulfate B C B A B B A BMaleic Acid B B A C A A A AMalic Acid C D A B A A A
D D D A D D D D BMercuric Chloride (Dilute Solution)Mercuric Cyanide D D A A A A Mercury C A A A A A A A AMethane A A A A A A A A AMethyl Acetate A B A A A AMethyl Acetone A A A A A A Methyl Alcohol 10 C B A A A AMethyl Butyl Ketone A A Methyl Cellosolve A Methyl Chloride D A C A AMethyl Ethyl Ketone A A A A AMethylamine A B B A A Methylene Chloride A B A A A A ANaptha A B B A A A A A ANapthalene B B A A B A B ANickel Chloride D D A A B ANickel Sulfate D D D A B A B BNitric Acid (10 Solution) D D D A A A A A ANitric Acid (20 Solution) D D A A A A ANitric Acid (50 Solution) D D A
B D A D B A B
A A A ANitric Acid
(Concentrated Solution)
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Nitrobenzene C B B A B A B BOleum B B A B A Oxalic Acid (cold) C D D A C A B A BPentane A B B A A C C BPerchloroethylene A B B A B A A Petrolatum B C C A A A Phenol 10 A B D A B A A BPhenol (Carbolic Acid) B D D A B A A A APhosphoric Acid
(to 40 Solution) D D A B A A APhosphoric Acid
(40-100 Solution) D D A C B B APhosphoric Acid (Crude) D D D A D C C A
D A A A Phosphoric Anhydride (Molten)Photographic (Developer) C D C A C APhthalic Anhydride B C C A B A B APicric Acid C D D A B A A APotash C B A A APotasium Bicarbonate C D A A B BPotassium Bromide C D D A A A B BPotassium Carbonate C B B A B A A APotassium Chlorate B B B A B A A A BPotassium Chloride B B B A C A A B APotassium Chromate A A B B B
D B B A BPotassium Cyanide Solutions A B A APotassium Dichromate A B C A B A A A BPotassium Ferrocyanide C C A B A A B
D C A A APotassium Hydroxide (50) B B B APotassium Nitrate B B A B A B A BPotassium Permanganate B B B A B A B B BPotassium Sulfate A B B A B A B B APotassium Sulde B B B A A A A BPropane (Liquied) A B A A A A Propylene Glycol A B B A B B A Pyridine B B A A C B Pyrogallic Acid B B B A B A A A ASilver Bromide D C C B Silver Nitrate D D D A B A B A ASodium Acetate B C C A B A A B ASodium Aluminate C C A B A BSodium Bicarbonate A C C A B A A A Sodium Bisulfate D D D A A A A BSodium Bisulte A D A A A BSodium Borate C C C A B A A ASodium Carbonate C B B A B A B B ASodium Chlorate B C A B A A BSodium Chloride C B C A B A C B ASodium Chromate D B B A A A A BSodium Cyanide D B B A B A A Sodium Fluoride C D D A B C C A
Sodium Hydrosulte A A ASodium Hydroxide (20) D A A
D B A A B AD C A A D BD C A A D B
A A A ASodium Hydroxide (50 Solution)Sodium Hydroxide (80 Solution)Sodium Hypochlorite (to 20)Sodium Hypochlorite D D D A D A ASodium Hyposulfate D A A A Sodium Metaphosphate A B B A A A Sodium Metasilicate B C C A A A Sodium Nitrate A A B A B A A A BSodium Perborate B B B A B C Sodium Peroxide C D C A B A A BSodium Polyphosphate
(Mono Di Tribasic) D A A A ASodium Silicate C B A B A B A BSodium Sulfate B A B A B A A C BSodium Sulde D A B A B A B BSodium Sulte C A A C C A
B C B A A A A Sodium Thiosulphate (ldquoHypordquo)Stannic Chloride D D D A D D D BStannous Chloride D D D A D D C AStearic Acid B C C A B A A A AStoddard Solvent A B B A A A A A AStyrene A A A A A A Sulfate Liquors B C C ASulfur Chloride D A D D D Sulfur Dioxide A A A A C BSulfur Dioxide (Dry) A A B A A A A ASulfur Trioxide (Dry) A B B A A A C Sulfuric Acid (to 10) C D A D C C ASulfuric Acid (10-75) D D A D D D BSulfurous Acid C D D A C C B C BTannic Acid C C C A B A A A BTanning Liquors C A A A ATartaric Acid C D D A B A B B BTetrahydrofuran D D A A A A Toluene Toluol A A A A A A A ATrichlorethane C C A C A ATrichlorethylene B C B A B A A AWater Acid Mine C C A A
B D A A A Water Distilled Lab Grade 7Water Fresh A B D A A A A Water Salt B D A A Weed Killers C A A Whiskey and Wines D D D A A A A A Xylene A A B A A A A AZinc Chloride D D D A D A B B BZinc Hydrosulphite D D A Zinc Sulfate D C D A B A A A B
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Flow
bull Volume RateTimebull ROTRON charts are in SCFM m3min or LSbull SCFM = Standard Cubic Feet Per Minute (American) where
temperature = 68degF air density = 0075 lbcubic foot and altitude = 0 feet above sea level
bull M3min = Cubic Meters Per Minute (Metric)bull Lsec = Liters Per Second (Metric)bull 1 m3min = 353 SCFMbull 1 Lsec = 2119 SCFMbull See Standard Engineering Conversions for other flows on
pg I-2
Throughout our catalog you will find terminology used for air moving selection and product sizing Below are a few of the key terms
Specic Gravity
bull Density Ratio Relative to Airbull Standard Air SG = 10bull Methane SG = 055bull See Specific Gravity Chart for other gases on pg I-4
Pressure
bull ForceAreabull ROTRON charts are in IWG PSIG MM of Water IHG or mbarbull IWG = Inches of Water Gauge (American)bull PSIG = Pounds Per Square Inch Gauge (American)bull MM of Water = Millimeter of Water Gauge (Metric)bull IHG = Inches of Mercury Gauge (American)bull mbar = Millibar Gauge (Metric)bull PSIA = Pounds Per Square Inch Absolute (American)bull 277 IWG = 1 PSIGbull 70358 MM of Water = 1 PSIGbull 2036 IHG = 1 PSIGbull 0069 Bars = 69 mbar = 1 PSIGbull Standard Atmosphere = 0 PSIG = 147 PSIAbull See Basic Fan Laws Chart for correcting pressure due to speed
or density changes on pgs I-5 and I-6
Density
bull WeightVolumebull Standard Air = 0075 lbcubic footbull See Density Chart for other gases on pg I-4bull See Density Correction Chart due to altitude and temperature
changes on pg I-3
Velocity
bull DistanceTime or FlowAreabull FPM = Feet Per Minute (American)bull MPH = Miles Per Hour (American)bull Mmin = Meters Per Minute (Metric)bull Kmh = Kilometers Per Hour (Metric)bull 88 FPM = 1 MPHbull 2682 Mmin = 1 MPHbull 1609 Kmh = 1 MPHbull See Standard Engineering Conversion Chart for other
velocities on pg I-2bull See Orifice Flow Calculation Chart for air flow equations on
pg I-7
Pressure Drop Back Pressure Impedance
bull Friction causes air to slow down and lost energy is measured in pressure drop terms
bull Typical pressure drop areas include piping elbows accessories and system
bull Each fixed system has a fixed system impedance caused by a single or multiple pressure drop points
bull Changing the system impedance will cause blowers work point to change
bull Changing the blower with fixed system impedance will change the working back pressure
bull See Friction Loss Per Foot of Tubing and Fitting Charts on pg I-8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Engineering Conversion
MULTIPLY BY TO OBTAINAtmospheres 760 Cms of MercuryAtmospheres 2992 Inches of MercuryAtmospheres 3390 Feet of WaterAtmospheres 10333 KgsSq InchAtmospheres 1013 x 105 PascalsAtmospheres 1470 PoundsSq InchAtmospheres 760 TorrsBars 09869 AtmospheresBars 1 x 106 DynesSq CmBars 1020 x 104 KgsSquare MeterBars 1450 PoundsSq InchBritish Thermal Units 02520 Kilogram-CaloriesBritish Thermal Units 7775 Foot-PoundsBritish Thermal Units 3927 x 10-4 Horsepower-HoursBritish Thermal Units 1054 JoulesBritish Thermal Units 1075 Kilogram-MetersBritish Thermal Units 2928 x 10-4 Kilowatt-HoursCentimeters of Mercury 001316 AtmospheresCentimeters of Mercury 04461 Feet of WaterCentimeters of Mercury 1360 KgsSquare MeterCentimeters of Mercury 01934 PoundsSq InchCentimetersSecond 1969 FeetMinuteCentimetersSecond 06 MetersMinuteCubic Centimeters 3531 x 10-5 Cubic FeetCubic Centimeters 6102 x 10-2 Cubic InchesCubic Centimeters 10-6 Cubic MetersCubic Centimeters 10-3 LitersCubic Feet 2832 x 104 Cubic CmsCubic Feet 1728 Cubic InchesCubic Feet 002832 Cubic MetersCubic Feet 003704 Cubic YardsCibic Feet 7481 GallonsCubic Feet 2832 LitersCu Ft of Water (60degF) 6237 PoundsCubic FeetMinute 4720 Cubic CmsSecCubic FeetMinute 04720 LitersSecondCubic FeetMinute 624 Lbs of WaterMinCubic Inches 1639 Cubic CentimetersCubic Inches 5787 x 10-4 Cubic FeetCubic Inches 1639 x 10-5 Cubic MetersCubic Inches 2143 x 10-5 Cubic YardsCubic Meters 106 Cubic CentimetersCubic Meters 3531 Cubic FeetCubic Meters 61023 Cubic InchesCubic Meters 1308 Cubic YardsCubic Yards 7646 x 105 Cubic CentimetersCubic Yards 27 Cubic FeetCubic Yards 46656 Cubic InchesCubic Yards 07646 Cubic MetersFeet 3048 CentimetersFeet 12 InchesFeet 03048 MetersFeet 13 YardsFeet of Air
(1 atmosphere 60degF) 530 x 10-4 PoundsSquare InchFeetMinute 05080 CentimetersSecFeetMinute 001667 FeetSecondFeetMinute 001829 KilometersHourFeetMinute 03048 MetersMinuteFeetMinute 001136 MilesHourGramsCu Cm 6243 PoundsCubic FootHorsepower 4244 British Thermal UnitsMinHorsepower 33000 Foot-PoundsMinHorsepower 1070 Kg-CaloriesMinHorsepower 7457 WattsHorsepower-Hours 2547 British Thermal UnitsInches 2540 CentimetersInches 103 MilsInches of Mercury 003342 AtmospheresInches of Mercury 1360 Inches of WaterInches of Mercury 3453 KgsSquare MeterInches of Mercury 2540 Mms of MercuryInches of Mercury 04912 PoundsSquare InInches of Water 0002458 AtmospheresInches of Water 007355 Inches of MercuryInches of Water 2540 KgsSquare MeterInches of Water 5204 PoundsSquare FtInches of Water 003613 PoundsSquare In
MULTIPLY BY TO OBTAINKGSCubic Meter 006243 PoundsCubic FootKilometers 3281 FeetKilowatts 5692 British Thermal UnitsMinKilowatts 7376 Foot-PoundsSecKilowatts 1341 HorsepowerKilowatts 1434 Kg-CaloriesMinKilowatt-Hours 3415 British Thermal UnitsLiters 103 Cubic CentimetersLiters 6102 Cubic InchesLiters 10-3 Cubic MetersLog10N 2303 LogEN or Ln NLog N or Ln N 04343 Log10NMeters 100 CentimetersMeters 32808 FeetMeters 3937 InchesMeters 10-3 KilometersMetersMinute 1667 CentimetersSecMetersMinute 3281 FeetMinuteMetersMinute 006 KilometersHourMetersMinute 003728 MilesHourMiles 5280 FeetMiles 16093 KilometersMiles 1760 YardsMilesHour 4470 CentimetersSecMilesHour 88 FeetMinuteMilesHour 1467 FeetSecondMilesHour 16093 KilometersHourMilesHour 2682 MetersMinuteMms of Mercury 00394 Inches of MercuryMms of Mercury 13595-3 KgsSquare CmMms of Mercury 001934 PoundsSquare InchPints (Liq) 2887 Cubic InchesPints (US liquid) 473179 Cubic CentimetersPints (US liquid) 16 Ounces (US fluid)Pounds 444823 DynesPounds 4536 GramsPounds 16 OuncesPounds of Carbon to CO2 14544 British Thermal Units (mean)Pounds of Water 2768 Cubic InchesPounds of Water 01198 GallonsPounds of Water
Evaporated at 212degF 9703 British Thermal UnitsPoundsCubic Foot 1602 KgsCubic MeterPoundsSquare Foot 4882 KgsSquare MeterPoundsSquare Inch 006804 AtmospheresPoundsSquare Inch 277 Inches of WaterPoundsSquare Inch 2036 Inches of MercuryPoundsSquare Inch 7031 KgsSquare MeterPoundsSquare Inch 6895 x 103 PascalsPoundsSquare Inch 51715 Millimeters of Mercury at 0degCSquare Centimeters 1973 x 105 Circular MilsSquare Centimeters 1076 x 10-3 Square FeetSquare Centimeters 01550 Square InchesSquare Feet 9290 Square CentimetersSquare Feet 009290 Square MetersSquare Inches 1273 x 106 Circular MilsSquare Inches 6452 Square CentimetersSquare Inches 6944 x 10-3 Square FeetSquare Inches 106 Square MilsSquare Inches 6452 Square MillimetersSquare Kilometers 1076 x 106 Square FeetSquare Kilometers 106 Square MetersSquare Kilometers 1196 x 106 Square YardsSquare Meters 10764 Square FeetSquare Meters 1196 Square YardsTemp (Degs C) + 273 1 Abs Temp (Degs C)Temp (Degs C) + 178 18 Temp (Degs Fahr)Temp (Degs F) + 460 1 Abs Temp (Degs F)Temp (Degs F) -32 59 Temp (Degs Cent)Watts 005692 British Thermal UnitsMinWatts 107 ErgsSecondWatts 4426 Foot-PoundsMinWatts 1341 x 10-3 HorsepowerWatts 001434 Kg-CaloriesMinWatts 10-3 KilowattsWatts-Hour 3415 British Thermal UnitsWatts-Hour 1341 x 10- HorsepowerHoursWatts-Hour 10-3 Kilowatt-Hours
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Density Correction Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Specic Gravity and Density of Various Gases at 60degF (1 ATM)
ChemicalFormula
Density(lbscu ft)
Gas or Vapor Specic Gravity
Acetylene 0899 0686Air 100 0763Ammonia 0587 0454Argon 1377 1053Benzene 270 205Carbon Dioxide 1539 1166Chlorine 2448 0738Ethane 1038 0799Ethylene 0969 0739Helium 0138 01054Hydrogen 00695 00531Hydrogen Sulde 119 0897Methane 0555 0424Methyl Chloride 1785 1356Nitrogen 0967 0738Oxygen 1105 0843Propane 155 1180Sulfer Oxide 226 1720Water Vapor 0622
C2H2
-NH3
AC6H6
CO2
CI2
C2H6
C2H4
HeH2
H2SCH4
CH3CIN2
O2
C3H8
SO2
H2O 0373
Explosive Atmosphere Classication
NEMA Classications
North American European
Class I Zone 1Group A AcetyleneGroup B Group II C
Group II CHydrogen or equivalent hazard
Group C Group II B Ethyle ether vapors ethylene orcyclopropane
Group D Group II A Gasoline hexane naptha benzenebutane alcohol acetone benzol lacquer vapors or natural gas
Class IIGroup E Metal dustGroup F mdash
mdashCarbon black coal or coke dust
Group G mdash Flour starch or grain
Temperature Conversion Chart
degC Temp degF degC Temp degF degC Temp degF degC Temp degF-789 -110 -166 17 35 950 272 81 1778 182 360 680-733 -100 -148 22 36 968 278 82 1796 188 370 698-678 -90 -130 28 37 986 283 83 1814 193 380 716-622 -80 -112 33 38 1004 289 84 1832 199 390 734-567 -70 -94 39 39 1022 294 85 1850 204 400 752-511 -60 -76 44 40 1040 300 86 1868 210 410 770-456 -50 -58 50 41 1058 306 87 1886 216 420 788-400 -40 -40 56 42 1076 311 88 1904 221 430 806-344 -30 -22 61 43 1094 317 89 1922 227 440 824-289 -20 -4 67 44 1112 322 90 1940 232 450 842-233 -10 14 72 45 1130 328 91 1958 238 460 860-178 0 32 78 46 1148 333 92 1976 243 470 878-172 1 338 83 47 1166 339 93 1994 249 480 896-167 2 356 89 48 1184 344 94 2012 254 490 914-161 3 374 94 49 1202 350 95 2030 260 500 932-156 4 392 100 50 1220 356 96 2048 266 510 950-150 5 410 106 51 1238 361 97 2066 271 520 968-144 6 428 111 52 1256 367 98 2084 277 530 986-139 7 446 117 53 1274 372 99 2102 282 540 1004-133 8 464 122 54 1292 378 100 2120 288 550 1022-128 9 482 128 55 1310 43 110 230 293 560 1040-122 10 500 133 56 1328 49 120 248 299 570 1058-117 11 518 139 57 1346 54 130 266 304 580 1076-111 12 536 144 58 1364 60 140 284 310 590 1094-106 13 554 150 59 1382 66 150 302 316 600 1112-100 14 572 156 60 1400 71 160 320 321 610 1130
-94 15 590 161 61 1418 77 170 338 327 620 1148-89 16 608 167 62 1436 82 180 356 332 630 1166-83 17 626 172 63 1454 88 190 374 338 640 1184-78 18 644 178 64 1472 93 200 392 343 650 1202-72 19 662 183 65 1490 99 210 410 349 660 1220-67 20 680 189 66 1508 100 212 413 354 670 1238-61 21 698 194 67 1526 104 220 428 360 680 1256-56 22 716 200 68 1544 110 230 446 366 690 1274-50 23 734 206 69 1562 116 240 464 371 700 1292-44 24 752 211 70 1580 121 250 482 377 710 1310-39 25 770 217 71 1598 127 260 500 382 720 1328-33 26 788 222 72 1616 132 270 518 388 730 1346-28 27 806 228 73 1634 138 280 536 393 740 1364-22 28 824 233 74 1652 143 290 554 399 750 1382-17 29 842 239 75 1670 149 300 572 404 760 1400-11 30 860 244 76 1688 154 310 590 410 770 1418-06 31 878 250 77 1706 160 320 608 416 780 1436
0 32 896 256 78 1724 166 330 626 421 790 145406 33 914 261 79 1742 171 340 644 427 800 147211 34 932 267 80 1760 177 350 662 432 810 1490
In the center column nd the temperature to be converted The equivalent temperature is in the left column if converting to Celsius and in the right column if converting to Fahrenheit
degF = 95C + 32 ABSOLUTE RANKIN (R) R = degF + 460degC = 59 (F - 32) ABSOLUTE KELVIN (K) K = degC + 273
Ref NEMA Standards Publication Pub No 1CSndash1970
NEMA Type 1 ndash General Purpose ndash IndoorType 2 ndash Dripproof ndash IndoorType 3 ndash Dusttight Raintight and Sleet (Ice)
Resistant ndash Outdoor3R ndash Rainproof and Sleet (Ice) Resistant
ndash Outdoor3S ndash Dusttight Raintight and Sleet (Ice)
Proof ndash OutdoorType 4 ndash W atertight and Dusttight ndash Indoor
4X ndash W atertight Dusttight and CorrosionResistant ndash Outdoor
Type 5 ndash Superseded by Type 12 for ControlApparatus
Type 6 ndash Submersible Watertight Dusttight andSleet Resistant ndash Indoor and Outdoor
Type 7 ndash Class I Group A B C or D HazardousLocations Air Break Equipment ndash Indoor
Type 8 ndash Class I Group A B C or D Hazardous Locations Oil-immersed Equipment ndash Indoor
Type 9 ndash Class II Group E F or G HazardousLocations Air-break Equipment ndash Indoor
Type 10 ndash Bureau of MinesType 11 ndash Corrosion Resistant and Dripproof
Oil-immersed ndash IndoorType 12 ndash Industrial Use Dusttight and Driptight
ndash IndoorType 13 ndash Oiltight and Dusttight ndash Indoor
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Physical Laws for Blower Applications
In the following formulae these symbols are used
P ndash Pressure in pounds per square inch (PSI) or inches ofmercury column (inches Hg)
CFM ndash Volume in cubic feet per minuteRPM ndash Speed in revolutions per minuteD ndash Density in pounds per cubic foot (lbscu ft)H ndash Height of air or gas column (ft)SG ndash Specic Gravity (ratio of density of gas to the density
of air)
ldquoStandard Airrdquo ndash Air at 68degF (absolute temperature 528deg) and 2992rdquo Hg (barometric pressure at sea level) The density of such air is 0075 lbscu ft and the specic volume is 1329 cu ftlb The specic gravity is 10
The outlet pressure of a blower depends on the condition of the air or gas at the inlet The inlet condition is inuenced bya ndash Specic gravity (The ratio of density of the gas to density of
standard air)b ndash Altitude (location of blower)c ndash Temperature of inlet air
Volume
Pressure
The Volume changes in direct ratio to the speedExample ndash A blower is operating at 3500 RPM and delivering 1000 cfm If the speed is reduced to 3000 RPM what is the new volume
Basic Fan Laws Chart
V REWOPESROHERUSSERPEMULOVELBAIRA
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio
Varies DIRECT with Density Ratio Varies DIRECT with Density Ratio
Varies with CUBE of Speed Ratio
CFM 2 = CFM 1 ( RPM 2 ) P 2 = P 1 ( RPM 2 )2 HP 2 = HP 1 ( RPM 2 )3
RPM 1 RPM 1 RPM 1
WHEN DENSITY CHANGES Does Not Change
P 2 = P 1 ( D2 ) HP 2 = HP 1 ( D2 )D1 D1
V 1 = Original Volume (1000 CFM)V 2 = New VolumeRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
V 2 = V 1 ( RPM 2 )1= 1000 x ( 3000 )1
= 1000 x 857 = 857 CFMRPM 1 3500
Pressure (barometric) varies in direct proportion toaltitudeExample ndash A blower is to operate at an elevation of 6000 feetand is to deliver 3 PSI pressure What pressure (standard air)blower is required
Pressure = 3 x 2992
= 375 or 3 34 lb2398
If it is desired to determine what pressure a 3 lb (standard air)blower will deliver at 6000 feet ndash
Pressure = 3 x 2398
= 24 or about 2 12 lb2992
When a blower is to operate at a high altitude it is frequentlyspecied that the blower be capable of handling a given vol-ume of ldquostandard airrdquo It is then necessary to determine theequivalent volume of air at the higher altitudeExample ndash A blower is to operate 6000 feet altitude and is tohandle 1000 CFM of standard air What is the CFM of air theblower must handle at 6000 feet altitude
Let V 1 = Volume of standard air (1000 CFM)V 2 = Volume of thinner airHg1 = Barometric pressure sea level (2992)Hg2 = Barometric pressure 6000rsquo (2398)
V 2 = V 1 x Hg
1 = 1000 x 2992
= 1248 CFMHg 2 2398
The pressure changes as the square of the speed ratio
Example ndash A blower is operating at a speed of 3500 RPM anddelivering air at 50 pounds pressure If the speed is reduced to3000 RPM what is the new pressure
P 1 = Original Pressure (5 lbs)P 2 = New PressureRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
P 2 = P 1 ( RPM 2 )2= 5 x ( 3000 )2
= 5 x 735 = 368 poundsRPM 1 3500
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Pressure (Contrsquod)
Horsepower
The Air Density varies in inverse proportion to theabsolute temperatureExample ndash A blower is to handle 200degF air at 3 PSI pressureWhat pressure (standard air) blower is required
Let P 1 = Pressure hot air (3 PSI)P 2 = Pressure standard airAT 1 = Absolute temperature hot air (200+460=660degF)AT 2 = Absolute temperature standard air (68+460=528degF)
P 2 = P 1 x AT
1 = 3 x 660 = 375 or 3 34 lbAT 2 528
A blower is capable of delivering 3 PSI pressure with standardair What pressure will it develop handling 200degF inlet air
P 1 = P 2 x AT
2 = 3 x 528 = 24 or about 2 12 lbAT 1 660
Pressure varies in direct proportion to the densityExample ndash A 3 lb (standard air) blower is to be used to handlegas having a specic gravity of 05 What pressure does theblower create when handling the gas
Let Pa = Air pressure (3 lb)Pg = Gas pressureSG = Specic gravity of gas (05)
Pg = Pa x SG = 3 x 5 = 15 lb
If we are required to handle a gas having a specic gravity of 05at 15 lb pressure we can determine the standard air pressureblower as follows
Let Pa = Pg
= 15
= 3 lbSG 5
The following table gives the barometric pressure of various altitudesAbsolute Pressure At Altitudes Above Sea Level (Based on US Standard Atmosphere)
Altitude
0500
Feet In Hg PSIA Feet In Hg PSIA Feet In Hg PSIA
600700800900
100015002000
299229382928291829072897288628332782
147014431438143314281423141813901367
250030003500400045005000550060006500
273126812632258425362489244323982353
134113191292127012451223120011771156
700075008000850090009500
10000
2309226522222180213820982058
1134111210901070105010901010
Pressure Altitude Pressure Altitude Pressure
The horsepower changes as the cube of the speed ratioExample ndash A blower is operating at a speed of 3500 RPM andrequiring 50 horsepower If the speed is reduced to 3000 RPMwhat is the new required horsepower
HP 1 = Original Horsepower (50)HP 2 = New HorsepowerRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
HP 2 = HP 1 x (RPM 2)3= 50 x (3000 )3
= 50 x 630 = 315 horsepowerRPM 1 3500
The above is known as the 1-2-3 rule of blowers
Horsepower vs Specic Gravity amp Ratio of densityThe horsepower varies in direct proportion to the specic gravity(ratio of density of gas to density of air)Example ndash A standard air blower requires a 10 HP motor Whathorsepower is required when this blower is to handle a gaswhose specic gravity is 05
HP = 10 x 05 = 5 horsepower
It is possible that several of the above modications may berequired on one installation Therefore it may be necessary touse various combinations of these formulae
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Orice Flow
Orice Flow CalculationTo determine air ow through an orice
V = CK radic P Q = AV VP = ( V ) 2K
WhereV = V elocity in feet per minute (fpm)C = Orice CoecientK = Constant = 14786 when P is expressed
in In Hg21094 when P is expressedin PSIG4005 when P is expressedin In of Water
(Above constants are based on an air densityof 0075 lbsft 3)
P = Pressure dierential across the oriceQ = Flow rate in cubic feet per minute (CFM)A = T otal orice area expressed in square feetVP = Velocity pressure (units are those of pressure)
Coecient C for Orices UnderVacuum or Pressure Flow
Area of OricesOrice Diameter in Inches
Diameterin Inches Square Inches Square Feet
18 01227 000085316 02761 0001914 04908 0003438 11044 0007612 19634 0013658 30679 0021378 60132 0041710 78539 00545
Orice area (in sq inches) = 25 X π X (orice diameter in inches) 2
Orice area (in sq feet) = Area in sq inches divide 144
ORIFICE PRESSURE DROP AS A FUNCTIONOF FLOW AND ORIFICE AREA (C=65)
c-98 c-92 c-82 c-80
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
c-72 c-65 c-80 c-53
15
30
45
60
75
90
105
120
135
150
20
40
60
80
100
120
140
160
180
20
0 100 200 300Flow Rate SCFM
400 500
500 700 900 1100Flow Rate SCFM
1300 1500
1500 1700 1900 2100Flow Rate SCFM
2300 2500
40
60
80
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Friction Loss Per Foot of Tubing
Friction Loss in Fittings
To calculate friction loss in ttings use chart below This chart will yield equivalentlengths (in feet) of tubing Use this length with graph above to nd friction loss ininches of water column
NOMINAL PIPE SIZE (INCHES) EQUIVALENT TUBING LENGTH (FEET)
90deg EL 45deg EL
1 14 3 151 12 4 2
52 252 12 6 3
47314 0 515 2 616 5 7528 0 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Noise Facts
Loudness Levels of Familiar Noises (Approximate Average Including Ear Nework)
bull OSHA (Occupational Safety amp Health Administration) regulates and monitors in-plant noisebull Allowable noise is a function of dBA level at certain distance over an exposure timebull OSHA regulations state 90 dBA for an 8 hour work period using slow responic setting on meterbull Adding a second noise producer of equal dBA will add 3 dBA to the first dBA readingbull Sound pressure level (SPL) decreases with distance (d)
(SPL) 2 = (SPL) 1 - 20LOG ( d2 )d1
Therefore each doubling of distance results in 6 dBA reduction
Threshold of Painful Feeling
Airplane and Propeller at 10
Ft
Train Passing at High Speed
Riveter at 30 Ft Auto Horn at 20 Ft Pneumatic Drill at 10 FtSubway TrainFire Siren at 75 Ft Noisy Street RailwayNoisy StreetPolice Whistle at 15 Ft Auto at 60 MPH
Very Noisy Restaurant Auto at 40 MPH Average Stenographic Room
Factories Auto at 20 MPHNoise in Pullman (Windows Shut)Noisy OfficeAverage RestaurantDept Store Average Conversation at 3 FtAverage Office Quiet Street Noisy ResidenceQuiet Restaurant Quiet OfficeMuseumAverage School Average Residence Motion Picture Theater Library Reading Rooms AuditoriumsAverage Whisper at 5 Ft Very Quiet Residence
Broadcasting Studio Zero of AIEE Scale 14 Db
Zero of Original Scale 85
Db Threshold of Audibility
1013 130
1012 120
1011 110
1010 100
109 90
108 80
107 70
106 60
105 50
104 40
103 30
102 20
10 10
1 1
Loud
ness
Lev
els
in D
ecib
els
Rel
ativ
e In
tens
ities
(Int
ensi
ty A
bove
Thr
esho
ld =
10
16 w
atts
per
sq
cm
)
A P
P R
O X
I M
A T
E
N O
I S
E
L E
V E
L S
DEAFENING
NOISY
AVERAGE
QUIET
VERY QUIET
SOUND PROOFR OOMS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 91258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Industrial Blower Noise Chart in dBA
dBA at Distance Conversion Chart
Average at 1 meter 4 places around the blower
Mode
Suction
SEMFRDCSL2SL4SL5
60-6264-6576-7869-7272-7876-79
60-6264-6576-7869-7272-7876-79
101202303353404454
65-6767-6965-6772-7373-7476-77
66-6868-7067-6973-7474-7575-76
5135055235556566
80-8177-7882-8380-8182-8385-86
80-8176-7782-8380-8182-8385-86
757808633S7858833
83-8584-8581-8288-8984-8582-84
84-8684-8581-8288-8984-8582-84
SP 99091233SP 13
14SP 15
90-9181-8284-8587-8886-8791-92
90-9184-8684-8590-9186-8791-92
Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure
Mode Mode Mode ModeModel Model Model Model Model
To read use straight edge to connect blower distance and dBA rating A pivot point A will be developed Use straight edge again with new distance and pivot point A to read dBA at new distance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 101258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference
Special Features 0 to 4 letters- see gure 2
Voltage Code up to 3 numbers - see gure 1
Motor Description - see gure 3(TEFC XP Chem and ODP)
Describes which family the unit belongs to 1 to 3 numbers
Option for duplex units onlyP = Parallel congurationS = Series conguration
DR = Domestic RegenerativeEN = EnvironmentalCP = Chemical ProcessHiE = Hi Eciency Motor
Figure 1 Voltage Code
Figure 2 Special Features
This chart explains the nomenclature behind the catalogued blower model names This tool can be used to explainto customers what the letters and numbers mean and will also allow you to become familiar with our model namesThis information should not aect the way orders are placed please continue to use the model names shown inthe catalog and price pages Any special request should be noted on the order
5 230 VAC 60 Hz Single Phase9 115230 VAC 5060 Hz Single Phase33 230 VAC 60 Hz Three Phase58 115230 VAC 60 Hz Single Phase60 200 VAC 5060 Hz Single Phase72 230460 VAC 60 Hz Three Phase75 380 VAC 50 Hz Three Phase86 575 VAC 60 Hz Three Phase89 200-230460 VAC 60 Hz Three Phase91 230460 VAC 5060 Hz Three Phase92 415 VAC 50 Hz Three Phase201 380 VAC 60 Hz
A SPECIAL (not covered by any other letter)BC Blower on pressure onlyD Blower on suction onlyEFGH Vapor recovery service - hydrocarbonJ Nasty Gas face sealKL Lo leak option (lip seal)M Die Cast or muer extensionPQR Chem-Toughtrade constructionS Special manifoldTUV V alveW Rail mounted blowerX Base mounted blowerY Slip on angeZ Package blower coupling driveAA Package blower belt drive simplexBB Package blower drive belt duplexRD Remote driveNT No Tower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference (Contrsquod)
HP Motor ThermalType Protection
HP Motor ThermalType Protection
Figure 3 Motor Description
DEFKMRVWXYADAEAGAKALARASAWAXAYBABBBCBDBEBGBHBKBLBMBPBQBRBXCBCCCD
CJCKCRCSCTCUDCDJDWDXEEEZFAFBFDFEFFFGFHFJFKFLFMFNFQFRFSFUFWFXFYFZGAGBGCGD
RD
25404030201018
11630306015121434255
75101530551412101520305055751015203020
XPTEFC
CHEM TEFCCHEMTEFCCHEM TEFCCHEM TEFC
TEFCTEFCTEFC
XPODP
CHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFC
XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XP
YesNoNoNoNoNoYesYesNoYesNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesYesYesYesYesYesYesYesYesYesYesNo
50505030301515157513131212121010202020757510101015152020152030403414141425
TEFCODPXP
TEFCXP
TEFCODPXP
ODPTEFC
XPTEFC
XPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCXP
ODPODPODPODPTEFCTEFCODPXP
TEFC
NoNoYesNoYesNoYesYesNoNoYesNoNoYesNoYesNoYesYesNoYesNoNoYesNoYesNoYesNoNoNoNoNoNoYesYesNo
CHEM TEFCTEFC
Remote Drive - No MotorGE 115 No
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Corrosion-Resistant and Sanitary Blowers Application Data Sheet
To obtain Application Engineering assistance or a quotation for your specific need please photocopy thisform fill out as much as possible and fax it back to Rotron We look forward to working with you
COMPANY
CONTACT
ADDRESS
ADDRESS
ZIPS TAT EC IT Y
FAXP HONE
GAS CONCENTRATION DESCRIPTIONPercentage Gas Specific Gravity
________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )___ __ _______________ (SG = _______ )
Corrosive Yes No Explosive Yes NoGAS
CLASSIFICATION
AREA
CLASSIFICATION
Corrosive Yes No Explosive Yes No
PERFORMANCE REQUEST Fill in and circle choice
SCFM deg (F C)FLOW INLET TEMPERATURE
PSI (A G) deg (F C)INLET PRESSURE AREA AMBIENT TEMPERATURE
PSI (A G) (Ft M)OUTLET PRESSURE SITE ALTITUDE
___ 100
APPLICATION DESCRIPTION Attach sketch if necessary
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 131258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Warranty Statement
Warranty Statements
1 AMETEK ROTRON DR EN and HiE regenerative direct drive blowers are guaranteed for one full year from the date of installation (limited to 18 months from the date of shipment) to the original purchaser only Should blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related
2 Standard Products - AMETEK ROTRON moisture separators remote drives packaged units CP blowers Nasty GasTM models and special built (EO) products are guaranteed for one full year from the date of shipment for workmanship and material defect to the original purchaser only Should the blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related we will at our option repair or replace the blower
3 Parts Policy - AMETEK ROTRON spare parts and accessories are guaranteed for three months from the date of shipment for workmanship and material defect to the original purchaser onlyIf failure is determined to be workmanship or material defect related we will at our option repair or replace the part
4 Non-Standard Products - Orders for specially-built products will be concidered as non-cancellable Any requested changed by customer after order acceptance will result in additional charges
Corrective Action - A written report will be provided indicating reason(s) for failure with suggestions for corrective action Subsequent customer failures due to abuse misuse misapplica-tion or repeat oense will not be covered AMETEK ROTRON will then notify you or your options Any failed unit that is tampered with by attempting repair or diagnosis will void the warranty unless authorized by the factory
Terms and Conditions - Our warranty covers repairs or replace-ment or regenerative blowers only and will not cover labor for installation outbound and inbound shipping costs accessories or other items not considered integral blower parts Charges may be incurred on products returned for reasons other than failures covered by their appropriate warranty Out-of-warranty product and in warranty product returned for failures deter-mined to be caused by abuse misuse or repeat oense will be subject to an evaluation charge Maximum liability will in no case exceed the value of the product purchased Damage resulting from mishandling during shipping is not covered by this warranty It is the responsibility of the purchaser to le claims with the carrier Other terms and conditions of sale are stated on the back of the order acknowledgement
Hazardous Locations Policy
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous explosive location without proper NEMA motor enclosure AMETEK ROTRON does not recognize sealed blowers as a substitue for explosion-proof motors Sealed units with standard TEFC motors should never be utilized where local state andor federal codes specify the use of explosion-proof equipment
AMETEK ROTRON has a complete line of regenerative blowers with explosion-proof motors Division 1 amp 2 Class I Group D Class II Groups F amp G requirements are met with these standard explosion-proof blowers
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous corrosive environment without the proper surface treatment and sealing options
AMETEK ROTRON has a complete line of Chemical Processing and Nasty GasTM regenerative blowers with Chem-ToughTM stainless steel parts and seals
AMETEK ROTRON oers general application guidance however suitability of the particular blower selection is ultimately the responsibility of the purchaser not the manufacturer of the blower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 14Customer Service Fax +1 2152561338 wwwametekdfscom
AMETEK Inc
AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with annualized sales of more than $25 billion AMETEK has nearly 11000 colleagues working at more than 80 manufacturing facilities and more than 60 sales and service centers in the United States and over 30 other countries around the world
AMETEK DYNAMIC FLUID SOLUTIONS (DFS)
AMETEK Technical amp Industrial Products is a world leader in motors blowers and pumps for mass-transit medical business machine and computer applications It also is a leader in regenerative blowers for pressure and vacuum applications used by broad range of industries
AMETEK supports its customers globally from its manufacturing facilities in Minnesota New York North Carolina Ohio Pennsylvania Italy and China Our brushless DC motors blowers controllers pumps and fans are ideally suited for a wide range of applications including medical instruments robotics pumps compressors offi ce equipment fans machine tools tape drives or any other precise rotary motionair delivery applications
Technical amp Industrial Productsrsquo product line of regenerative blowers for pressure and vacuum applications services the process industrial environmental waste and wastewater industrial industry Typical applications areas include solution agitation and aeration pneumatic conveying part hold-down and pick up part blow off gas and fume extraction and process gas handling
AMETEK Technical amp Industrial Products supplies the solution for unique performance mounting environmental and agency requirements
DYNAMIC FLUID SOLUTIONS
100 East Erie St Kent OH USA 44240USA +1 330-677-3327 - Europe +49 7703 930909 - Asia +86 21
5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Untitled
- Untitled
- Untitled
- Untitled
- Blank Page
- Blank Page
- Blank Page
- Blank Page
-
Regenerative Principle
Rotation
Out
In Air Flow
The impeller blades passing the inlet port draw air or other gases into the blower The impeller blades then by centrifigal action accelerate the air outward and forward Here the ldquoregenerativerdquo principle takes effect as the air is turned back by the annular shaped hous-ing to the base of the following blades where it is again hurled outward Each ldquoregenerationrdquo imparts more pressure to the air When the air reaches the stripper section at the outlet (the stripper is the part of the blower located between the inlet and the outlet in which the annulus is reduced in size to fit closely to the sides and tips of the impeller blades) the air is ldquostrippedrdquo from the impeller and diverted out of the blower The pressures or vacuums generated by each spinning non-contacting oil-free impeller are equal to those obtained by many larger multi-stage or positive displacement blowers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Table of Contents
A Nine Major Blower Application Areas B Product Dimensional Listing C Industrial Chemical Processing Blowers
DR P15 C57 400 600 HP Regenerative Blower
DR S15 C59 400 HP High Pressure Regenerative Blower
DR 068 C1125 HP Regenerative Blower
D Environmental Chemical Processing Blowers EN 101 amp CP 101 D1
DR 083 C3 5 HP Sealed Regenerative wExplosion-Proof Motor
125 HP Regenerative Blower EN 303 amp CP 303 D3
DR 101 amp CP 101 C5 5 HP Sealed Regenerative wExplosion-Proof motor
33 HP Regenerative Blower EN 404 amp CP 404 D5
DR 202 amp CP 202 C7 10 HP Sealed Regenerative wExplosion-Proof Motor
33 HP Regenerative Blower EN 454 amp CP 454 D7
DR 303 amp CP 303 C9 15 HP Sealed Regenerative wExplosion-Proof Motor
33 HP Regenerative Blower EN 505 amp CP 505 D9 DR 353 amp CP 353 C11 20 25 HP Sealed Regenerative wExplosion-Proof Motor 75 HP Regenerative Blower EN 513 amp CP 513 D11 DR 404 amp CP 404 C13 15 HP Sealed Regenerative wExplosion-Proof Motor 10 HP Regenerative Blower EN 523 amp CP 523 D13 DR 454 amp CP 454 C15 30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
15 HP Regenerative Blower EN 6 amp CP 6 D15 DR 505 amp CP 505 C17 50 HP Sealed Regenerative wExplosion-Proof Motor
20 30 HP Regenerative Blower EN amp CP 633 D17 DR 513 amp CP 513 C19 75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
15 HP Regenerative Blower EN 656 amp CP 656 D19 DR 523 amp CP 523 C21 30 HP Sealed Regenerative wExplosion-Proof Motor
3 HP High Pressure Regenerative Blower EN 757 Single-Phase and CP Options D21 DR 555 amp CP 555 C23 Sealed Regenerative Blower wExplosion-proof Motor
30 40 HP Regenerative Blower EN 757 amp CP 757 D23 DR 6 amp CP 6 C25 30 50 HP Sealed Regenerative wExplosion-Proof Motor
30 50 HP Regenerative Blower EN 808 Single-Phase and CP Options D25 DR 633 amp CP 633 C27 Sealed Regenerative Blower wExplosion-proof Motor
30 40 50 HP Regenerative Blower EN 808 amp CP 808 Three-Phase D27 Sealed Regenerative Blower wExplosion-proof MotorDR 656 amp CP 656
C29 30 40 50 HP Regenerative Blower EN 833 amp CP 833 D29
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor DR 757 amp CP 757 C31 40 50 HP Regenerative Blower EN 858 amp CP 858 D31
75 100 HP Sealed Regenerative wExplosion-Proof Motor DR S7 C33 75 HP High Pressure Regenerative Blower EN 909 amp CP 909 D33
100 150 HP Sealed Regenerative wExplosion-Proof Motor DR 808 amp CP 808 C35 50 75 HP Regenerative Blower EN 979 amp CP 979 D35
200 HP Sealed Regenerative wExplosion-Proof Motor DR 833 amp CP 833 C37 75 100 HP Regenerative Blower EN 14 amp CP 14 D37
200 300 HP Sealed Regenerative wExplosion-Proof Motor DR 858 amp CP 858 C39 75 100 HP Regenerative Blower
DR P9 C41 E Remote Drive (Motorless) Blowers MF573RD E1
150 200 HP Regenerative Blower SL2RD E2 DR S9 C43 DRENCP 404RD E3 150 200 HP High Pressure Regenerative Blower DRENCP 505RD E4 DR 909 amp CP 909 C45 DRENCP 513RD E5 100 150 HP Regenerative Blower DRENCP 523RD E6 DR 979 amp CP 979 C47 DRENCP 6RD E7 150 200 HP Regenerative Blower DRENCP 656RD E8 DR 1233 amp CP 1233 C49 DRENCP 757RD E9 200 HP High Pressure Regenerative Blower DRENCP 858RD E10 DR P13 C51 DRENCP 909RD E11 200 300 HP Regenerative Blower DRENCP 979RD E12 DR S13 C53 DRENCP 1233RD E13 200 300 HP High Pressure Regenerative Blower DRENCP 14RD E14 DR 14 amp CP 14 C55 200 250 300HP Regenerative Blower
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Table of Contents
F Application Specific Blowers Minispiral F1 Insrument Grade Regenerative Blower
Minispiral MDC F3 Variable Flow Regenerative Blower
Minispiral 1224V HDC F5 Variable Flow Regenerative Blower
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy F7 Variable Flow Regenerative Blower
SPIRAL Simplex SL2 F9 Insrument Grade Regenerative Blower
SPIRAL Duplex SL4 F11 Insrument Grade Regenerative Blower
SPIRAL Duplex SL5 F13 Insrument Grade Regenerative Blower
Nautilair F15 DR 404454505513656 F17 Spa Blowers
DR 10RDNTSS10RDNTHS 10RDNT F19 Remote Drive (Motorless) Blowers
MD 101 Magnetic-Drive F21 Regenerative Blower
GVR313 F23 Regenerative Blower
G Accessories Filtration - Inlet Filter (Single Connection) G1 Filtration - Inline Filter (Dual Connection) G2 Filtration - Filter Silencers (Single Connection) G3 Filtration - Filter Element G4 Filtration - Moisture Separator G5 Measurement - Air Flow Meter G7 Measurement - Digital Flowmeter G9 Noise Reduction - Sound Attenuating Enclosure G10 Noise Reduction - InletOutlet Muffler (Single Connection) G11 Noise Reduction - Inline Muffler (Dual Connection) G12 Protection - Relief Valve - Mechanical G13 Protection - Pressure Regulating Diaphram Valve G14 Protection - Gauges G15 System - Variable Frequency Drive G16 System - Air Knives G17 System - 5 Way 3 Port 2 Position Diverter Valve G19 System - Air Flow Switch G21 Pressure amp Vacuum Arrangements G22 H Motor Blower Options I Application Engineering Basics
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 1 Air-Assisted Breathing
Your own imagination and knowledge are probably the best source of in-plant and on-site applications for ROTRON regenerative blowers This guide will help to pinpoint and stimulate your consideration of the many alternative sources we provide to replace costly and maintenance intensive suction and pressure units and systems The nine major application groups are listed and a cross reference of the most common applications by industry will help you identify both identical and similar applications in your industrial operations
Nose
Part
Blower
Blower
Blower
Blower
Blower
Block
Box
BlowerWork Table
Work
Work
Plenum
PneumaticSuction Cups
Mouth
Flotation Tables
Air Slides Air Tables Turning amp Forming Bars
Air Film SupportAir BagsWeb
General Parts Pick-Up General Parts Hold-Down
Vacuum Manipulator Flotation Tables
Throat
ManufacturingPARP Respiration
MiningPARP Respiration
Application 2 Air-Assisted Inflation or SupportMaterial HandlingAir SlidesAir TablesCarbon Black Car Unloading
Paper ProcessingFlotation TablesForming BarSheet FlutteringTurn Bars
TextileGarment Flotation Tables
Water Pollution ControlPollution ContainmentWaterway Management
Application 3 Air-Assisted Vacuum Pick-Up or Hold-DownManufacturingBag Filling EquipmentCutting TablesPackaging EquipmentVacuum ManipulatorsCorrugated and Paperboard BoxesFlexible Packaging - Paper Plastic Aluminum Foil Textile Packaging and Steel StrappingRigid PackagingBeverage ContainersCosmetic and Toiletry ContainersBlister PacksPharmaceutical PackagingFood PackagingSterile Medical Device PackagingLabelsPressure Sensitive Tape
Paper or Plastics HandlingCutting TablesDiaper Making EquipmentPrinting Presses
TextileGarment Cutting TablesYarn Guiding and TensioningYarn AspirationCarboard Case Erector
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 4 Air amp Gas Sampling Boosting or Circulating
Fluid Bed Regeneration Transmissometer Lens Purging
Natural Gas Boost Air amp Gas Sampling
Combustion Air Boost
Pressurized Cabinet Vacuum Pull-Through Cabinet
Soil Vapor Extraction ampLandll Gas Recovery Vent Header O-Gassing
Fume amp Smoke Removal Digester Gas Collection
Air Pollution ControlAir SamplingAir Stream Release MonitoringFire Prevention Air SamplingFlue Gas Sampling
FoundryCombustion Air Boost
InstrumentationGlove Box PressurizingIncubator Air CirculationWeather Measurement Sampling
ManufacturingCombustion Air BoostNatural Gas BoostOil Demisting
PharmaceuticalClean Room Air CirculationOxygen Generator
Plastics HandlingDesiccant Dryer Bed Regeneration
Application 5 Electronic CoolingInstrumentationEngineMotor CoolingFilm Development System CoolingLamp Bank CoolingSmall Enclosure Cooling
Application 6 Gas Vapor amp Fume Recovery Venting amp TreatmentPharmaceuticalSterilization Gas (ETO) Recovery
ReneriesCentrifuge Venting
Water Pollution ControlDigester Gas Collection
AgriculturalMethane Gas RecoveryChemical ProcessingVent Header O-Gassing
EnvironmentalGasoline Vapor RecoveryLagoon Gas RecoveryLandll Gas RecoveryRadon Gas CollectionSoil Vapor Extraction
FoundryLost Foam O-Gassing
Manufacturing - Plant ServicesCabinet Fume VentingEnvironmental Test Chamber VentingLaser Smoke RemovalWeld Smoke Removal
Natural Gas
Blower
Blower
Blower
Blower
BlowerFilter
Blower
Blower Flame
Digester
Scrubber ChemicalTank
Treatment System
Electronics
Gas
CombustionChamber
BlowerBlower Blower
Light Beam
Lens
Stack
Lens
Natural GasFurnace
Minispiral
Instrument
Blower
Electronics
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 7 Solid Material Transporting Separation amp CollectionFoundrySand Reclamation
Manufacturing - Waste ControlChip Dust amp Particle RemovalLiquid amp Solvent RemovalPaper Plastic Film amp Textile (Trim) Removal
Material HandlingAir SlidesBlast CleaningDilute Phase ConveyingPneumatic Tube
PackagingBag Filling
Application 8 Parts Blow-Off amp Drying
Application 9 Solution amp Media Agitation amp AerationAquacultureAquarium Fish Farm Hatchery amp Pond Aeration
Groundwater Sparging
ManufacturingConcrete Fluid Bed AerationElectroplating Tank Agitation
Material HandlingFluidized Beds
RecreationCommercial Spa Aeration
Water ManagementBoat Dock amp Dam Face Deicing
Water Pollution ControlUV Tube AgitationWatewater Filter BackwashWastewater Treatment Tank Aeration
ManufacturingConveyor Belt Blow-OElectroplating Fume GuidingElectroplating Parts DryingElectroplating Solution Blow-BackFlat or Irregular Metal Parts DryingWire Drying
Aqueous Precision CleaningAutomotive Parts DryingSemiconductor Board Drying
Food ProcessingBatter Blow-OBottle amp Can DryingLabel DryingSalt Spice amp Flour Blow-O
Dilute Phase Pneumatic Conveying Pneumatic Tube
Paper Plastic Film amp Textile (Trim) Removal
General Parts Blow-O amp Drying Solution Blow-Back
Wastewater Treatment Tank Aeration Groundwater Sparging
Electroplating Tank Aeration Commercial Spa Aeration
Bin Pad amp Fluidized Bed Aeration Boat amp Dock Deicing
General Material Separation amp Collection
PressureBlower
Blower
Blower CollectionChamber
Blower
Blower
Blower
Blower
Blower
ProductBin Aerator
(Air Pads)
Blower
Blower Dock
Water
Hot Tub
Plating Bath
Spargers
Blower
Blower Ground Level
Soil
Water Table
Plating Tank
Air Knife
Hoist
Blower
Air Knife
TubeCarrier
Ejector
Bin
RotaryAirlock
DischargeTo Process
Cyclone
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Product Dimensional Listing
Blowers Shipping Wt (LBS) Carton Length (In) Width (In) Height (In)
DREN
068 16- 12 12 12
083 18- 12 12 12
101 3047 16 15 14
202 30- 16 15 14
303 4252 16 15 14
353 54- 21 16 16
404 6481 21 16 16
454 6084 21 16 16
505 8292 21 16 16
513 7699 24 12 22
523 112126 24 16 22
555 96- 21 16 16
633 241288 25 18 20
656 110117 24 16 22
6 148167 25 18 20
S7 206- 25 18 20
757 131158 25 18 20
808 285287 34 23 26
833 269297 44 29 37
858 280338 34 23 26
S9 P9 400- 34 23 26
909 373524 34 23 26
979 345533 34 23 26
1233 400- 34 23 26
14 620737 43 28 33
S13 P13 687- 43 28 33
S15 P15 909- 43 28 43
Minispirals (SE212) 2- 8 8 6
Nautilairs (NC33) 18- 16 15 14
Spiral (SL245) 42- 16 15 14
Note Model weight will vary by HP and voltage Refer to individual specication sheets to verify
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 B 1Customer Service Fax +1 2152561338 wwwametekdfscom
Industrial Chemical Processing Blowers AMETEK Dynamic Fluid Solutionsrsquo ROTRON brand has long been a world leader in regenerative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial DR (Domestic Regenerative) blowers include
Rugged cast aluminum housing cover impeller and muffler tower Removable cast iron flanges bolted to a sheet metal manifold TEFC motors on single-ended models ODP motors on all double-ended models Carbon steel shaft and zinc plated hardware Permanently sealed motor bearings for 20000-25000 hours life
Our CP (Chemical Processing Regenerative) blowers include
Chem-ToughTM surface conversion corrosion resistant treatment for aluminum castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Chemical Duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
OUTIN
(2) PLACES
85
671 99
302 100
616
155
029
39
23
641
097
371 94
152
60 DIA
35 DIA
(2) MTG HOLES
162
5876
174
216
9
553
1405
100 OD
8
22
25
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR068DJ9Y
Specification Units 081657
Motor Enclosure - Shaft Mtl - TEFC - CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 16 Kg 73
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 1 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 13 SCFMbull Maximum pressure 135 IWGbull Maximum vacuum 135 IWGbull Standard motor 18 HP TEFCbull Cast aluminum blower housing impeller amp cover slip-on steel flangesbull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Various horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR068 DR068
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 2 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
789
200
4
125
8492156
702
328 120833
1783
INOUT
448
113
8
139
685174
037
295
650
749
1651
736
DR083DC9Y - 036862
101(2 MTG HOLES)
397 DIA305
318
(2 P
LACE
S)
94
353
1869NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR083DC9Y
Specification Units 081572
Motor Enclosure - Shaft Mtl - TEFC -CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 18 Kg 82
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 3 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 24 IWGbull Maximum vacuum 232 IWGbull Standard motor 18 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR083 DR083
0 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
600 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
60
0
50
100
0
50
100
100
0
100
50
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 4 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
0 2 10 12 14 16 18 20 220
4 86
50
0
0 2 10 12 14 16 18 20 220
4 86
Temperature curves are based on standard model
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
115292
211
94
236
131
824 519
37
931
41102 MTG HOLES
312
6579
165741188
106 27
11
1997740
044
1
ROTATIONDIRECTION
1-11 12FEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR101Y9M DR101Y72M DR101Y86M CP101FB91MLR
Specification Units 038936 038937 038938 038225
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 033 033 033 033 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 3417 131206 06 13-1206 Service Factor - 135 125 125 125 Max Blower Amps Amps (A) 3417 13065 04 13065 Locked Rotor Amps Amps (A) 16482 64-5829 42 64-5829 NEMA Starter Size - 0000 00-0000 00 00-0000
Shipping Weight Lbs 30 30 30 30 Kg 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 5 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum ow 31 SCFM
bull Maximum vacuum 285 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR101 DR101
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 6 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
1178299
100
0
64 83
1130
963
394100
72
39
127
114
254
518
252 327
286
22
131
283
044
245
45
503153
81220628912263
STANDARDROTATION88
398 DIA10
1 14-11 12 NPSCSTRAIGHT THREAD(2X) CAST IRON FLANGES
(4X)
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR202Y9M DR202Y72M DR202Y86M CP202AE72MLR CP202FA91MLR
Specification Units 080564 080565 080566 038953 038227
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 33 033 033 033 033 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 3417 1206 05 1206 1206 Service Factor - 135 135 135 135 135 Max Blower Amps Amps (A) 5226 154077 057 154077 154077 Locked Rotor Amps Amps (A) 16482 6432 26 6432 6432 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 30 30 30 30 30 Kg 136 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 7 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 40 IWGbull Maximum vacuum 35 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR202 DR202
0 5 10 15 20 25 30 35 40 45 50 55
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 8 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
101(4) MTG HOLES
394
1001
2065
813
L10
0
254
519
132
1
245
64
327
831
113
287
961
2446
45
283
50
127
114
3
72
144
366
112
044
DR303AE9MDR303AE72MDR303AE86M
MODEL L (INMM)1186301211629461193303
891
2263
2 ROTATION DIRECTION
398 DIA
FEMALE THREADBOTH PORTS
1 14 - 11 12 NPSCNOTES
1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR303AE9M DR303AE72M DR303AE86M CP303FA91MLR
Specification Units 038841 038842 038843 080148
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 05 05 05 05 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 6231 13-1206 06 13-1206 Service Factor - 125 125 125 125 Max Blower Amps Amps (A) 63 163083 07 163083 Locked Rotor Amps Amps (A) 21105 10-9246 42 10-9246 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 34 42 42 42 Kg 154 191 191 191
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 9 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 48 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR303 DR303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 10 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
IN
OU
T
L12
22
311
31579
37595
12(4) MTG HOLES
1275324
513
622
115
555
512130
1018
Oslash613
041
10
356
175
292
141
130
90
158 44
156
258BOTH PORTS MODEL
DR353BR9M
DR353BR72M
L (INMM)
1397355
125317
8932268
47 DIA
1 12 - 11 12 NPSC THREAD
ROTATION DIRECTION1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR353BR9M DR353BR72M DR353BR86M CP353BR72MLR CP353FD72MLR
Specification Units 080554 080555 080556 081562 081612
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 075 075 075 075 075 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three 60 Hz Three 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 10050 3015 096 3015 3015 Service Factor - 115 125 125 125 125 Max Blower Amps Amps (A) 126 35175 10 35175 35175 Locked Rotor Amps Amps (A) 596298 15276 61 15276 15276 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 60 54 54 54 54 Kg 272 245 245 245 245
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 11 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 34 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR353 DR353
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 12 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
375
167
424
119(4) MTG HOLES
2921115
512
893
130
2268
L
4125
046
2816
0
121
830
94
718
182
4
305792 953
12633208
041 89
DR404AL58MDR404AL72MDR404AL86M
MODEL L (INMM)144136601418360213383399
FEMALE THREADBOTH PORTS
1032616
1
1 12 - 11 12 NPSC
47 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA KNOCK-OUT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR404AL58M DR404AL72M DR404AL86M CP404CU72MLR
Specification Units 037407 037406 037408 038233
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 10 10 10 10 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 11457 3015 12 3015 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 145725 4020 14 4020 Locked Rotor Amps Amps (A) 7035 210105 76 210105 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 69 64 64 64 Kg 313 29 29 29
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 58 IWGbull Maximum vacuum 50 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR404 DR404
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 14 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
IN OUT
475
325 178
1256
15
431
135
L
120
7
418
106
436
111524
133
20
69
175
114
475120
290
51
318
042 11
FEMALE THREAD
(6) MTG HOLES
MODEL
DR454R58MDR454R72M
L (INMM)
14473671331338
83 45
110
319
343
BOTH PORTS
125
10302616
451143
59 DIA
ROTATION DIRECTION
1 12 - 11 12 NPSC
1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR454R58M DR454R72M DR454R86M CP454EZ72MLR
Specification Units 080481 080480 080482 080491
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 5060 Hz Three - 5060 Hz Three - 5060 Hz Three - 5060 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 15678 4623 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 189 5226 21 5226 Locked Rotor Amps Amps (A) 8442 3216 128 3216 NEMA Starter Size - 10 0000 00 0000
Shipping Weight Lbs 73 60 60 60 Kg 331 272 272 272
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 15 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 60 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR454 DR454
0 15 30 45 60 75 90 105 120 135 150 1650
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
2240 25 51 76 102 127 153 178 204 229 255 280
15 30 45 60 75 90 105 120 135 150 165
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
00
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 16 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
IN
L
144
3
356
1418
59 DIA
(4) MTG HOLES
475
1030
1170 REF
725
191
37
REF
C B
1359 DIA
15
MODEL DR505AS58M
DR505AS72MDR505AS86MDR505K58MDR505K72M
1563397
1563397
14753741438365170431
L (INMM)
425108437111
437111
463117
463117
B (INMM)564143
525133
564143518131
C (INMM)
518131
FEMALE THREADBOTH PORTS
OUT
45
1143904
3602
366
5
184
2
485
1207
2616
2972
94
1824
3452
1 12 - 11 12 NPSC
ROTATION DIRECTION
1
718 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR505AS58M DR505AS72M DR505AS86M DR505K58M DR505K72M CP505FE72MLR CP505CT72MLR
Specification Units 037542 037543 037544 081882 037551 038239 038237
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS CHEM TEFC - SS Horsepower - 20 20 20 30 30 30 20 Voltage AC 115230 230460 575 115230 230460 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F F NEMA Rated Motor Amps Amps (A) 18291 5427 23 256128 7638 7638 5427 Service Factor - 115 115 115 115 115 115 115 Max Blower Amps Amps (A) 24115 735 30 2814 8844 8844 6834 Locked Rotor Amps Amps (A) 13869 3819 21 19497 8844 8844 3819 NEMA Starter Size - 10 0000 00 150 00 00 0000
Shipping Weight Lbs 97 82 84 91 86 86 82 Kg 44 372 381 413 39 39 372
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 17 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 73 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
0 15 30 45 60 75 90 105 120 135 150 16515 30 45 60 75 90 105 120 135 150 165 0
0
50
100
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
50
100
0
50
100
0
50
100
0
37
75
112
149
187
224 2240 25 51 76 102 127 153 178 204 229 255 280
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
0
0
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 18 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
OUTIN
182
1421
160
6
15
408
507
413
88
24
48
128
05
ROTATION
(4) MTG HOLES
106
61
224
122
BOTH PORTSFEMALE THREAD 325
360
937
18
1369346
372
129
1142896
5501397
1388
35261
59 DIA
1 12 - 11 12 NPSC
13
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR513R72 DR513R58 DR513R86 CP513EZ72LR
Specification Units 037217 037209 037773 038241
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 4623 16884 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 525 1995 185 525 Locked Rotor Amps Amps (A) 4321 12060 13 4321 NEMA Starter Size - 0000 10 00 0000
Shipping Weight Lbs 76 95 76 76 Kg 345 431 345 345
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 19 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 80 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR513 DR513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 20 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
IN OUT
3462
1397
3597
(4) MTG HOLES
564
220
7
1206
2901
3251
FEMALE THREADBOTH PORTS
1363
550
222
869
475
128
1142
L16
12
409
5
419 10
8
47
1194
1416
1443658
150
05
13
1421
3581
695
425
108
523
133
MODELDR523K72DR523K58
1591404119314905
L (INMM)
1 12 - 11 12 NPSC
ROTATION DIRECTION
59 DIA
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR523K72 DR523K58 DR523K86 CP523CS72LR
Specification Units 037210 037211 037772 038243
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-SS Horsepower - 3 3 3 3 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three-60 hz Single-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 88-8643 27135 34 88-8643 Service Factor - 115 10 10 115 Max Blower Amps Amps (A) 89445 3015 34 89445 Locked Rotor Amps Amps (A) 913457 19698 364 913457 NEMA Starter Size - 00 151 0 00
Shipping Weight Lbs 112 145 112 112 Kg 508 658 508 508
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 21 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 158 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR523 DR523
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 22 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
MODEL
DR555K72DR555K58
DR555CK72
L (INMM)
1744443
16124091738441
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
1506
1493L
Part Model Number
DR555CK72 DR555CK86 DR555K72 DR555K58 DR555K86 CP555CS72MLR
Specification Units 081100 081102 081099 081098 081101 038245
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 40 40 30 30 30 30 Voltage AC 230460 575 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 105 41 7638 256128 3 7638 Service Factor - 115 115 115 10 10 115 Max Blower Amps Amps (A) 1365 42 8844 2814 34 8844 Locked Rotor Amps Amps (A) 9447 80 8844 19497 70 8844 NEMA Starter Size - 10 0 00 151 0 00
Shipping Weight Lbs 113 137 96 91 90 90 Kg 513 621 435 413 408 408
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 23 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 92 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR555CK72DR555K72DR555K58
LegendPressureSuction
DR555CK72DR555K72DR555K58
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 24 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
OUTIN
486
241
1234L
95
165
163
441
5
1463
698 70 200508
40
215
98
50
848334 401016
FEMALE THREADBOTH PORTS
3201016
2032800
MODEL
DR6D89
DR6K72
L (INMM)
18004572
18004572
MUFFLER
2 - 11 12 NPSC
1
562 DIA
ROTATION DIRECTION
419
177 178
850
215
9
102
141
75
58(4) MTG HOLES
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR6D89 DR6D5 DR6D86 DR6K72 CP6FF72LR HiE6D89
Specification Units 027578 036212 027579 027600 038253 038071
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 50 50 50 30 50 50 Voltage AC 230460 230 575 230460 230460 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 11255 21 48 133-126 173-15678 173-15678 Service Factor - 115 10 115 115 115 115 Max Blower Amps Amps (A) 168 25 54 126 15-14874 15-14874 Locked Rotor Amps Amps (A) 165-15576 124 60 10653 165-15576 165-15576 NEMA Starter Size - 11 15 1 10 11 11
Shipping Weight Lbs 148 156 148 132 148 148 Kg 671 708 671 599 671 671
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 25 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 912 IWGbull Standard motor 50 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
designs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR6D89DR6K72DR6D5
LegendPressureSuction
DR6D89DR6K72DR6D5
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
0
50
100
52248 1 pc
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 26 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
NOTES
1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
98 (2X)249
118113000
20
51
322
10502667
818
6101549
6221580
IN OUT
DIRECTIONOFROTATION
103262
189
448
11
4881240
266676 1841
4676
17244 4380
1806 4587
13163343
105
9 26
90
16684237
2 NPSCFEMALE THREADBOTH PORTS
INMM
INCLUDES INLET FILTER
Part Model Number
DR633AY72M DR633AY86M DR633D89M CP633FG72LRM
Specification Units 081691 081693 081689 081695
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 75 75 5 75 Voltage AC 230460 575 208-230460 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 23-21105 84 169-15376 23-21105 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 198-189 79 15-13668 198-189 Locked Rotor Amps Amps (A) 17085 55 165-15576 17085 NEMA Starter Size - 21 1 1-10 21
Shipping Weight Lbs 241 241 223 241 Kg 1093 1093 1012 1093
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 27 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 275 IWGbull
bull Maximum vacuum 190 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR633AY72MDR633D89M
LegendPressureSuction
DR633AY72MDR633D89M
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 28 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
414
151
738
25
059
1052 140
1512384
L
556
141
(4X) MTGHOLES
15
15423905
746
190
456
116
Oslash7191826
225 0
6417
3
114202896
492125
572
2 NPSCSTRAIGHT THDSBOTH PORTS
MODEL L (INMM)
DR656CK72XDR656K72X
1750444516004064
12813254
551
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR656CK72X DR656CK86X DR656CK5X DR656K72X DR656K58X CP656CR72XLR
Specification Units 080582 080583 080584 080602 080603 080065
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC-CS TEFC - CS TEFC - CS CHEM TEFC-SS
Horsepower - 35 35 35 30 30 35Voltage AC 230460 575 230 230460 115230 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 10050 40 18 7437 29145 10050 Service Factor - 115 10 115 115 10 115 Max Blower Amps Amps (A) 11457 52 18 945 278139 11457 Locked Rotor Amps Amps (A) 9447 80 115 5427 17286 9447 NEMA Starter Size - 10 0 1 00 1510 10
Shipping Weight Lbs 110 114 101 103 114 110 Kg 499 517 458 467 517 499
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 29 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull
bull Maximum vacuum 89 IWGbull Standard motor 40 HP TEFCbull
bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
bull Cast iron cover for additional noise resonance
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 30 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
174
444
3
L
504
16
20
571
702
20
281
153389
167
426
063
R03179
CL OF BLOWER9
23
277 575
84
657
1675
128
50
50
71
145
178
ROTATIONDIRECTION
234
70 146 21
MODEL
DR757CK72X
DR757CK86X
DR757D89XDR757D86X
DR757D5MX
1855471
18554711855471
1855471
L (INMM)
5601422
2621031
163414
12733233
1
2 12 NPSCFEMALE THREADSBOTH PORTS
1855471
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (26) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR757CK72X DR757CK86X DR757D89X CP757FF72XLR CP757CR72XLR
Specification Units 081172 081173 081169 081178 081179
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS CHEM TEFC-SS Horsepower - 40 40 50 50 40 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 hz Three - 60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 105 40 126 126 105 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 126 42 15576 15576 126 Locked Rotor Amps Amps (A) 9447 80 19497 19497 9447 NEMA Starter Size - 10 0 10 10 10
Shipping Weight Lbs 131 128 140 140 131 Kg 594 581 635 635 594
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 31 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 83 IWGbull
bull Maximum vacuum 75 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg 0
C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR757D89XDR757CK72X
LegendPressureSuction
DR757D89XDR757CK72X
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22451 102 153 204 255 306 357 408 459 510 561
37
75
112
149
187
224
0
0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 32 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
2303
700
1100
200
OUTIN
400
800
494
1150
322
644
1638
588
1778 508
2794
818
101
6
1255
2032
2921
1636
1494
143(4) MTG HOLES
A
A
FEMALE THREADBOTH PORTS
FEMALE THREADBOTH PORTS
SECTION VIEW A-A
585
164
441
76
803204
4161
825
558
147
820
96
563 DIA
2 - 11 12 NPT
2 - 11 12 NPT
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS7X72 DRS7X86
Specification Units 036085 036144
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 19497 78 Service Factor - 115 10 Max Blower Amps Amps (A) 2412 96 Locked Rotor Amps Amps (A) 16683 66 NEMA Starter Size - 11 1
Shipping Weight Lbs 206 206 Kg 934 934
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 33 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 75 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS7
LegendPressureSuction
DRS7
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 34 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
IN OUT
L
536
421
12
143(8) MTG HOLES
875222
191485
18734757
09
229
359
912
117
529
8
C
35889
177870
FEMALE THREADBOTH PORTS
MODEL
DR808D89MXDR808AY72MX
L (INMM)2223564619314905
17434427
1575
14763749
4001
738187585
21622385685
562 DIA
1
2 12 - 8 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR808AY72MX DR808AY86MX DR808D89MX CP808FG72MXLR HiE808AY72MX
Specification Units 081222 081224 081225 081233 081228
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 75 75 50 75 75 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 17889 72 173-15678 17889 17889 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 108 147 2814 2814 Locked Rotor Amps Amps (A) 12060 60 15276 12060 12060 NEMA Starter Size - 11 1 10 11 11
Shipping Weight Lbs 285 242 195 285 301 Kg 1293 1098 885 1293 1365
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 35 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR808AY72MXDR808D89MX
LegendPressureSuction
DR808AY72MXDR808D89MX
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 36 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
NOTES
FILTER 515255 INCLUDED1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
MTG HOLEDETAIL
(4X)
20
51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
193
849
23
84213
5241331
ROTA
TION
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
IN OUT
1881 4778
17638 44801
104
426
52
19134859
1050 DIA2667
13983551
2406096
8712212
Part Model Number
DR833BB72M DR833BB86M DR833AY72M DR833AY86M CP833FH72MLR
Specification Units 081702 081704 081699 081701 081710
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 10 10 75 75 10 Voltage AC 230460 575 230460 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 31-2814 96 23-21105 84 31-2814 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 26-2412 89 212-19296 77 26-2412 Locked Rotor Amps Amps (A) 19095 73 17085 68 19095 NEMA Starter Size - 21 1 21 1 21
Shipping Weight Lbs 269 269 260 260 269 Kg 122 122 1179 1179 122
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 37 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 258 IWGbull
bull Maximum vacuum 174 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR833BB72MDR833AY72M
LegendPressureSuction
DR833BB72MDR833AY72M
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 38 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
902
OUT IN
FEMALE THREADBOTH PORTS
355
1860
400
(4) PLACES
19750
200
1016
4724
6811753
13533437
22345674
119
218
155
39
101
825
91
1000
13003302
2563
7091803
831
211
1116
829
67
101
325
73
641626
9992525
1905 X 508
L
MODEL DR858AY72WDR858BB72W
L (INMM)230658572319589
8492156
175950
2413
ROTATION DIRECTION
2 12 - 8 NPSC
75 X 200 SLOT
508
445
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR858BB72W DR858BB86W DR858AY72W CP858FH72WLR HiE858BB72W
Specification Units 038740 038742 038738 038749 038743
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 10 10 75 10 10 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 2613 105 17889 2613 2613 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 12 2814 2814 2814 Locked Rotor Amps Amps (A) 16281 65 12060 16281 16281 NEMA Starter Size - 21 1 11 21 21
Shipping Weight Lbs 280 280 264 280 280 Kg 127 127 1197 127 127
Model (Base Mount) - DR858BB72X DR858BB86X DR858AY72X Part Number (Base Mount) - 038735 038737 038736
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 39 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 125 IWGbull Maximum vacuum 1048 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR858BB72WDR858AY72W
LegendPressureSuction
DR858BB72WDR858AY72W
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 40 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
925
12003048
A
A
816
207
3
218
1 RE
F
1000
7091801
355902
FEMALE THREADBOTH PORTS
(4) PLACES
180
0 D
IA
457
2
400 DIA SLIP-ON1016
L
2349
142
10882764
554
100
025
4
254
756192
SECTION VIEW A-A
MODEL DRP9BM72CDRP9BL72C
L (INMM)3175806533448494
2
1
2 12 - 8 NPSC
ROTATION DIRECTION
56 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 PRESSURE OUTLET CONNECTION2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP9BM72C DRP9BM72D DRP9BM86C DRP9BM86D DRP9BL72C DRP9BL72D
Specification Units 037033 036275 037040 036276 036512 036513
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP-CS ODP - CS ODP-CS ODP - CS Horsepower - 20 20 20 20 15 15 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 49245 49245 20 20 37185 37185 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 6030 6030 222 222 5025 5025 Locked Rotor Amps Amps (A) 306153 306153 115 115 256128 256128 NEMA Starter Size - 32 32 2 2 22 22
Shipping Weight Lbs 400 408 464 408 380 418 Kg 1814 1851 2105 1851 1724 1896
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 41 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 116 IWGbull Maximum vacuum 95 IWGbull Standard motor 20 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP9BM72CDRP9BL72C
LegendPressureSuction
DRP9BM72CDRP9BL72C
0 80 160 240 320 400 480 560 640 720 800 880 0
0 136 272 408 544 680 816 951 1087 1223 1359 1495
80 160 240 320 400 480 560 640 720 800 880
136 272 408 544 680 816 951 1087 1223 1359 14950
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 42 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
1050 925
1200
223
3048
A
A
218
1
7091801
355902
XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX
FEMALE THREADBOTH PORTS
L
2349
100
554
254
816
207
3
56 (142) DIA (DRS9BL72)
500127756
19051000
254SECTION VIEW A-A
L (INMM)
31758065
33448494
MODEL
DRS9BM72
DRS9BL72
180
457
2
2 12 - 8 NPSC
60 X 135 SLOT(4) (DRS9BM72)
ROTATION DIRECTION
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS9BM72 DRS9BM86 DRS9BL72
Specification Units 037032 037041 036514
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 20 20 15 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 4824 20 3618 Service Factor - 115 115 10 Max Blower Amps Amps (A) 5628 204 5628 Locked Rotor Amps Amps (A) 288144 115 222111 NEMA Starter Size - 32 2 22
Shipping Weight Lbs 446 446 418 Kg 2023 2023 1896
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 43 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 206 IWGbull Maximum vacuum 157 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS9BL72CDRS9BM72C
LegendPressureSuction
DRS9BL72CDRS9BM72C
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
50
100
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 44 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
--
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
IN MM
NOTES1 TERMINAL BOX CONNECTOR HOLE 125 (318) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
Part Model Number
DR909BE72W DR909BE86W DR909BB72W DR909BB86W CP909FJ72WLR HiE909BE72W
Specification Units 081737 081739 081738 081744 038632 081735
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 15 15 10 10 15 10 Voltage AC 208-230460 575 230460 575 208-230460 208-230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 Hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 415-376188 146 2613 105 415-376188 415-376188 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 4221 17 3417 130 4221 4221 Locked Rotor Amps Amps (A) 318159 164 16281 65 318159 318159 NEMA Starter Size - 22 2 21 1 22 22
Shipping Weight Lbs 400 400 400 400 400 400 Kg 1814 1814 1814 1814 1814 1814
Model (Base Mount) DR909BE72X DR909BE86X DR909BB72X DR909BB86X Part Number (Base Mount) 038622 038626 038623 080183
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 45 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 137 IWGbull Maximum vacuum 106 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards when properly piped and
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR909BE72WDR909BB72W
LegendPressureSuction
DR909BE72WDR909BB72W
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 46 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
OUT IN
ROTATIONDIRECTION
1303302
952413
L
11252858
193490298
2489
204
518
216
88
428
8B
C D
E
L (INMM)MODEL
DR979BH72W
DR979BE86W
D (INMM) E (INMM)2907366
25386446
25816556
1319335
9882509
9882509
B (INMM) C (INMM)
12253112
10252604
10252604
8382129
8382129
8092055
6881748
6881748
11502921
DR979BE72W
1
4 NPSCPORTS
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 109 DIA (DR979BE72W)
1375 DIA (DR979BH72W)2 75 (191) X 200 (508) 4X MOUNTING SLOTS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR979BH72W DR979BE72W DR979BE86W DR979BH86W CP979FJ72WLR HiE979BE72W
Specification Units 080718 080704 080702 080719 081777
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 20 15 15 20 15 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - H H H H H H NEMA Rated Motor Amps Amps (A) 4623 4422 146 4623 4422 4422 Service Factor - 115 125 115 115 125 125 Max Blower Amps Amps (A) 6030 5226 21 6633 5226 5226 Locked Rotor Amps Amps (A) 294147 290145 93 294147 290145 290145 NEMA Starter Size - 32 22 2 32 22 22
Shipping Weight Lbs 350 300 300 350 300 300 Kg 1588 1361 1361 1588 1361 1361
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 47 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 1100 SCFMbull Maximum pressure 80 IWGbull Maximum vacuum 87 IWGbull Standard motor 15 HP TEFCbull Cast aluminum blower housing impeller amp cover cast iron flanges
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Chemical duty high efficiency inverter duty or industry-specific designsbull Vairous horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Slip-on or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR979BE72WDR979BH72W
LegendPressureSuction
DR979BE72WDR979BH72W
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 48 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
200 HP High Pressure Regenerative Blower
NOTES1 TERMINAL BOX CONNECTOR HOLE 138 (35) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
Part Model Number
DR1233BH72W DR1233BH86W CP1233GD72LRW
Specification Units 081375 081377 081379
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 20 20 20 Voltage AC 208-230460 575 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 51-4623 184 51-4623 Service Factor - 15 115 15 Max Blower Amps Amps (A) 50-4623 178 50-4623 Locked Rotor Amps Amps (A) 397199 159 397199 NEMA Starter Size - 32 2 32
Shipping Weight Lbs 400 400 400 Kg 1814 1814 1814
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 49 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 255 IWGbull Maximum vacuum 175 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR1233
LegendPressureSuction
DR1233
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
Inlet Filter part 522948
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 50 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
NOTES1 081801 DRP13BP72C MODEL SHOWN2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
PART NUMBER
081801
113028702
94423976
47211995
43010922
84721514
C
E
122131013
355790348
145436932
95024130
94824079
130533134
57314554
40010160
2050
10462657
177845171
FLEX TUBING (2X)
4rdquo - 8 NPT (2X)FEMALE THREAD
6rdquo - 8 NPSC FEMALE1533886 DEEP
125231788
G
75 X 200 SLOT191 X 508 (4X)
H
ROTATIONDIRECTION
081802
081804
081805
081798
081797
DRP13BP72C
DRP13BP72D
DRP13BP86C
DRP13BP86D
DRP13BM72C
DRP13BM72D
1130287
1130287
1130287
1130287
105526797
105526797
250163525
250163525
250463525
250463525
242661611
242661611
125231788
125231788
125231788
125231788
107727343
107727343
2508
2508
2508
2508
1383505
1383505
MODEL C INMM H INMM G INMM E INMM
INMM
Part Model Number
DRP13BP72C DRP13BP72D DRP13BP86C DRP13BP86D DRP13BM72C DRP13BM72D
Specification Units 081801 081802 081804 081805 081798 081797
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS Horsepower - 30 30 30 30 20 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 7035 7035 28 28 49245 49245 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 380190 380190 174 174 306153 306153 Max Blower Amps Amps (A) 11055 11055 36 36 6432 6432 NEMA Starter Size - 33 33 3 3 32 32
Shipping Weight Lbs 687 687 687 687 592 592 Kg 3116 3116 3116 3116 2685 2685
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 51 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 103 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP13BP72CDRP13BM72C
LegendPressureSuction
DRP13BP72CDRP13BM72C
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 52 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
944
1130
472
112
8
107743
847
1454
9501
081363
OUT
IN
1233
2736
2398
2870
1199
286
525
04
63621
51
109
2
SECTION VIEW A-A
35579035
197
950
27
3693
274
3462 2413
4241077
3132
204
952
04
BOTHPORTS
1
SLOTS75x200(19x508)(4) PLACES
3
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4rdquo-8 NPSC FEMALE THREAD BOTH PORTS3 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS5 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING6 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS13BP72 DRS13BP86 DRS13BM72
Specification Units 081800 081803 081799
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 30 30 20 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 7839 28 49245 Service Factor - 115 115 115 Max Blower Amps Amps (A) 8040 32 70153 Locked Rotor Amps Amps (A) 380190 174 306153 NEMA Starter Size - 33 3 32
Shipping Weight Lbs 646 646 562 Kg 293 293 2549
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 53 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 195 IWGbull Maximum vacuum 132 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS13
LegendPressureSuction
DRS13
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 54 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
11001311
128
8
17004318
MODELDR14DW72MW
L (INMM) D (INMM)19850331558014
L
751905
29257430
276
701
0972
2477
300762
2794
17574463
234
659
59
327
2
333
9652451
11572939
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
D
SEE NOTE 1
2332 DIA5923
1531 DIA3889
SEE NOTEOUT IN 1
NOTES1 LIFTING SLOT 100 X 170 (254 X 432)2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR14DW72MW DR14DW86MW DR14DT72MW DR14BH72MW CP14FK72MWLR HiE14DW72MW
Specification Units 081476 081479 081483 081480 081490 081497
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 30 30 25 20 30 30 Voltage AC 230460 575 230460 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 6633 265 5829 4623 6633 6633 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 9045 328 9045 6030 9045 9045 Locked Rotor Amps Amps (A) 430215 172 304152 294147 430215 430215 NEMA Starter Size - 33 3 33 32 33 33
Shipping Weight Lbs 696 694 650 600 696 696 Kg 3157 3148 2948 2722 3157 3157
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 55 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 120 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 56 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
141
411
42
588
A
2404 REF
969
296
4
1562
1250
1034
OUT IN
SECTION VIEW A-A
1238
295
3
10114
233
0 D
IA
121
2 320
1 RE
F
OU
T IN
359
2
149
4
290
1
752
9
2461
6106
3145
3967
3175
2626
750
1
591
8
307
8
813
1
A
1129
1429363
1725
11252858
43822868
39823982714281 DIA
(2 PLACES)
19(4) PLACES
508
300762
1
2
3
75 X 200 SLOTNOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 PRESSURE CONNECTION 6-8 NPSC FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP15EE72C DRP15EE72D DRP15BQ72C DRP15BQ72D DRP15BQ86C DRP15BQ86D
Specification Units 081499 081629 081501 081500 TBD TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP - CS ODP - CS ODP - CS ODP - CS Horsepower - 60 60 40 40 40 40 Voltage AC 230460 230460 230460 230460 575 575 Phase - Frequency - Three-60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 14070 14070 9648 9648 384 384 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 870435 870435 630315 630315 540270 540270 Max Blower Amps Amps (A) 17085 17085 16080 16080 64 64 NEMA Starter Size - 54 54 43 43 3 3
Shipping Weight Lbs 1025 1025 923 923 923 923 Kg 4649 4649 4187 4187 4187 4187
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 57 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 115 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 58 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
2469
A
OU
T
IN
IN
OUT
A
SECTION VIEW A-A
972
BOTHPORTS
1
4
2
5
3
1082743
12503175
1563962
600
152
4
286
726
4
1313327
140
355
610
626
92
1343404 104
2642
17254382
28401118
1162946
1293277
3929957
234
594
4
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 FOUR MOUNTING SLOTS 75 (19) X 200 (508)4 TWO LIFTING SLOTS 100 (254) X 170 (432)5 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS6 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING7 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS15BQ72 DRS15BQ86
Specification Units 081502 TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 40 40 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 9648 384 Service Factor - 115 115 Max Blower Amps Amps (A) 14070 52 Locked Rotor Amps Amps (A) 630315 216 NEMA Starter Size - 43 3
Shipping Weight Lbs 923 923 Kg 4187 4187
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 59 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200 IWGbull Maximum ow 925 SCFM
bull Maximum vacuum 1347 IWGbull Standard motor 40 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Quiet operation within OSHA standards when properly piped or mued -
1 inlet muer included
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS15
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
40
80
120
160
200
240
0
100
200
300
400
500
600
0
50
100
0
50
100Temperature curves are based on standard model
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 60 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers Our environmental EN blowers are designed the same as the DR blowers except added features include
Heavy duty cast aluminum manifold Our spark resistant housing cover impeller muffler tower and manifold are
vacuum impregnated Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Explosion-proof motors standard and available in a variety of world voltages All metal-to-metal surfaces are sealed with RTV sealant
Various UL explosion-proof listings Consult factory
Environmental (EN) regenerative blowers are also available in our Chemical Processing (CP) configuration
Chem-ToughTM surface conversion corrsion resistant treatment for all castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less
Chemical duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
7741956
6131557
13753493
8622190
4651181
963
244
6
140
1
312793325
826
650
752 1651
1910
4131049
125
1
553
1 - 11 12 NPSCFEMALE THREADBOTH PORTS
1
ROTATIONDIRECTION
38 (96) DIA2X MTG HOLES
100
355
9
317
8
140
5
254
040
102
NOTES1 TERMINAL BOX CONNECTOR HOLE 75rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN101AG58L EN101AG91L CP101FN58LR CP101FN91LR
Specification Units 038171 038019 080622 038950
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 7437 9045 7437 9045 Locked Rotor Amps Amps (A) 63 1575 63 1575 Service Factor Amps (A) 3819 8945 3819 8945 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 47 47 47 47 Kg 213 213 213 213
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 25 IWGbull Maximum vacuum 23 IWGbull Standard motor 05 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN101
LegendPressureSuction
EN101
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 2Customer Service Fax +1 2152561338 wwwametekdfscomcom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
OUTIN
338 327
575
108
2
859 831
274
8
048
197
406
891
39450
1031
10(4) MTG HOLES
12043058
137
3485
7914
71
698
177
3
961
1090
397 DIA
1
122
2441
1001
2263
1 14 - 11 12 NPSCFEMALE THREADBOTH PORTS
146
12769
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREADgt2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN303AG58L EN303AG91L CP303FN58LR CP303FN91LR
Specification Units 038172 038026 080247 038954
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 9045 1575 9045 1575 Locked Rotor Amps Amps (A) 7236 16383 7236 16383 Service Factor Amps (A) 3819 89445 3819 89445 Starter Size - 000 0000 000 0000 Thermal Protection - 10 135 10 135 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 52 52 52 52 Kg 236 236 236 236
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP explosion-proof
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN303 EN303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor
628
375
492
666
512
893
159
5
112
1692
125
2268
130(4) MTG HOLES
L12
23
311
2
304762 953
11632954
119
718
182
4
2921
044
10132573
EN404AR72MLEN404AR58MLMODEL L (INMM)
1641416815503937
ROTATION DIRECTION
1
47 DIA
115 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN404AR58ML EN404AR72ML CP404FQ58MLR CP404FQ72MLR
Specification Units 038173 038174 080075 038958
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 10 10 10 10 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 208-230460 115230 208-230460 Max Blower Amps Amps (A) 114569 3216 114569 3216 Locked Rotor Amps Amps (A) 14472 3618 14472 3618 Service Factor Amps (A) 7236 202101 7236 202101 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 81 64 81 64 Kg 367 29 367 29
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor ATEX model certified
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 52 IWGbull Maximum vacuum 48 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN404
LegendPressureSuction
EN404
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
50
100
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
177
3
488
3175
120
7
698
125
475
4751206
107
4501143
327
831 452
(6) MTG HOLES
3327
178
192
042
135
3
1310
15
1367
2896
2616
538
114 REF
1030
343
7
18704750
1
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN454W58ML EN454W72ML CP454W72MLR CP454FR72MLR
Specification Units 080487 080488 080490 080494
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-CS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 115208-230 230460 230460 230460 Motor Nameplate Amps Amps (A) 1579-75 4623 4523 4623 Max Blower Amps Amps (A) 19109-95 5628 5628 5628 Locked Rotor Amps Amps (A) 96-48 3216 3216 3216 Service Factor - 10 0000 0000 0000 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 90 84 84 84 Kg 408 381 381 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 59 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN454 EN454
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN505AX58ML EN505AX72ML CP505FS58MLR CP505FS72MLR
Specification Units 038177 038178 080655 038962
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 20 20 20 Phase - Frequency - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Voltage AC 115230 230460 115230 230460 Motor Nameplate Amps Amps (A) 2211 5829 2211 5829 Max Blower Amps Amps (A) 2412 6432 2412 6432 Locked Rotor Amps Amps (A) 11256 5628 11256 5628 Service Factor - 10 00 10 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 92 84 92 84 Kg 417 381 417 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull Maximum vacuum 70 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN505AX72MLEN505AX58ML
LegendPressureSuction
EN505AX72MLEN505AX58ML
0
50
100
0
50
100
0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
OUTIN
442
112340
44
372 550
1364
1387
1397945
3465
(4) MTG HOLES
2248
822
35
569
475
128
1206
140
3251
05
127
1819
14213609
669170
553
15703988
159
2
3523
15
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN513W58L EN513W72L CP513FR58LR CP513FR72LR
Specification Units 038183 038037 038966
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115208-230 230460 115208-230 230460 Max Blower Amps Amps (A) 1579-75 4623 1579-75 4623 Inrush Amps Amps (A) 19497-90 5427 19497-90 5427 Service Factor Amps (A) 84-42 3216 84-42 3216 Starter Size - 10 0000 10 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 99 93 99 93 Kg 449 422 449 422
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 75 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN513 EN513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
OUTIN
5501397
(4) MTG HOLES
3609
571
1142
128
4751206
145
2901
3251
19194874
6561666
160
140
87 7
16556
1412
15683983
15
1421
575
146
10
5012
7
143
836
53
222
6058
6922
38
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN523M5L EN523M72L CP523FU5LR CP523FU72LR
Specification Units 038223 038184 TBD 038968
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 230 230460 Max Blower Amps Amps (A) 155-145 7437 155-145 7437 Locked Rotor Amps Amps (A) 181-167 84 181-167 84 Service Factor Amps (A) 94-88 6231 94-88 6231 Starter Size - 1 00 1 00 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D I-D I-D I-D
Shipping Weight Lbs 126 126 150 126 Kg 572 572 68 572
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN523 EN523
0
50
100
0
50
100
0
50
100
0
50
100
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
850
200
400
558
1638
598
800
1150
215
9
508
141
7
101
6
4161
1519
2032
2921
143(4) MTG HOLES
423
916
69
FEMALE THREADBOTH PORTS419
106416
222
825
209
6
7181824
7001778
L
16184110
7751969
095246
6371618
MODEL L (INMM)
562 DIA
2 - 11 12 NPSC
NOTE 1
2055207EN6F72L20845292EN6F5L
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD
POSITIONED AT 12 OrsquoCLOCK2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN6F5L EN6F72L EN6F86L CP6FW5LR CP6FW72LR
Specification Units 038361 038180 038438 TBD 038978
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 50 50 50 50 50 Phase - Frequency Voltage - Single-60 hz Three-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 575 230 230460 Max Blower Amps Amps (A) 195 147 57 195 147 Locked Rotor Amps Amps (A) 23 147 63 23 147 Service Factor Amps (A) 175 15276 38 175 15276 Starter Size - 2 10 0 2 10 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 190 167 167 190 167 Kg 862 757 757 862 757
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 85 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
Muffler included (part 522948)
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN6F72LEN6F5L
LegendPressureSuction
EN6F72LEN6F5L
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
bull
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
103 262
A C
DIRECTION OF ROTATION
B
ROTA
TIO
N
1171 2974
20 51
322
818
10
59
269
0
IN OUT
622 98 (2X) 1580 610 249 154926611811
6763000 D
1841
2 - 11 12 NPSCFEMALE THREAD
1806 4676 BOTH PORTS
4587
IN MM 512
MTG HOLE 130
591
150 DETAIL
(4X) MODEL A B C DNOTES
1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD EN633 181 1894 167 173 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN EN833 182 1959 180 176
PartModel Number
CP633FY72LREN633BA72LM
081697Specification Units 081698
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1785 1785 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Lbs 288 288Shipping Weight Kg 1306 1306
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200195 IWGbull
bull Maximum vacuum 155155 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0
20 40 60 80 100 120 140 160 180 200 220
34 68 102 136 170 204 238 272 306 340
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
414
746
1542
696
538
1052
3917
176
818
95
STRAIGHT THDS2 NPSC
BOTH PORTS
136
7
(4X) MTGHOLES
19374920
151
738
25
551140
05915
1512
1826719
231
587
064
173 492
125
382512813254
114202901
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN656M5XL EN656M72XL EN656M86XL CP656FU72XLR
Specification Units 080060 080059 080058 080142
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 208-230 208-230460 575 208-230460 Motor Nameplate Amps Amps (A) 155-145 7437 30 7437 Max Blower Amps Amps (A) 17 105 41 105 Locked Rotor Amps Amps (A) 95-86 5427 216 5427 Service Factor - 1 00 0 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 142 117 117 117 Kg 644 531 531 531
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull
bull Maximum vacuum 73 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN656M72XLEN656M5XL
LegendPressureSuction
EN656M72XLEN656M5XL
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
15363901
233517
24
437
9
194
349
35
5931
950
604
2413
130033021534
445175
168
242
72
258
610
18
5731455
10332624
8502159
16644227
1000254
166
9
233
2
663
657
261
918
ROTATIONDIRECTIONOUT IN
2 12 NPSCFEMALE THREADSBOTH PORTS
1
75 X 200 SLOT19508(4) PLACES
INMM
PartModel Number
EN757FL5MWL CP757FX5MWLR
Specification Units 081333 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS CHEM XP-SS Horsepower - 55 55 Phase - Frequency - Single-60 hz Single-60 hz Voltage AC 230 230 Motor Nameplate Amps Amps (A) 217 217 Max Blower Amps Amps (A) 299 299 Locked Rotor Amps Amps (A) 155 155 Service Factor - 1 1 Starter Size - 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D I-D
Shipping Weight Lbs 158 158 Kg 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 21Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
0
0
0
20
40
60
80
100
120
0
50
100
0
50
100
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Legend Pressure Suction
EN757FL5WL
120 40 80 120 160 200 240 260 300 340 380 420
68 136 204 272 340 408 442 510 578 546 714
mba
r
0
50
100
150
200
250
300
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
R031
CL OF BLOWER79
19906316
505
657
261
166
966
3
ROTATIONDIRECTION
L
174
444
3
182
718
MODELEN757M72XLEN757F72XL
L (INMM)1972500921005334
15363886
284
20
508
559
142
715
181
6
16754255
923
234
4
16094087
IN OUT
088
5601422
5731461
10372634
15353899
2 12 NPSCFEMALE THREADSBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
IN
MODELPART NO
NAMEPLATEMOTOR
INMM
PartModel Number
EN757M72XL EN757M86XL EN757F72XL CP757FW72XLR CP757FU72XLR
Specification Units 081176 081177 081174 081180 081181
Motor Enclosure - Shaft - XP-CS XP-CS XP-CS CHEM XP-SS CHEM XP-SS Mtl Horsepower - 30 30 50 50 30 Voltage AC 208-230460 575 208-230460 208-230460 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three - 60 Hz Three-60 Hz Three - 60 Hz Insulation Class - B B B B B NEMA Rated Motor Amps Amps (A) 7236 30 147 147 7236 Service Factor - 10 10 10 10 10 Maximum Blower Amps Amps (A) 105 40 1575 1575 105 Locked Rotor Amps Amps (A) 5447 22 15276 15276 5427 Starter Size - 00 0 11 11 00
Shipping Weight Lbs 158 158 158 158 158 Kg 717 717 717 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN757F72XLEN757M72XL
LegendPressureSuction
EN757F72XLEN757M72XL
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 24Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options Sealed Regenerative Blower wExplosion-proof Motor
2335 103359311536 2624 573
101
825
86
168
242
72
918
233
2 6
57
261
663
166
9
3901
1
OUT
1455
IN ROTATION DIRECTION
2 12 NPSC FEMALE THREADS BOTH PORTS
850
194
349
35
172
443
79
950175 2159
NOTES 1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
604
2413
1300 33021534
445 IN
MM 75 X 200 SLOT 19508 (4) PLACES 1664
4227
1000 254
PartModel Number
EN757FL5MWL EN808FL5MWL CP757FX5MWLR CP808FX5MWLR
Specification Units 081333 081231 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 55 55 55 55 Phase - Frequency - Single-60 hz Single-60 hz Single-60 hz Single-60 hz Voltage AC 230 230 230 230 Motor Nameplate Amps Amps (A) 217 217 217 217 Max Blower Amps Amps (A) 299 299 299 299 Locked Rotor Amps Amps (A) 155 155 155 155 Service Factor - 1 1 1 1 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Class B - Pilot Class B - Pilot Class B - Pilot XP Motor Class - Group - Duty I-D Duty I-D Duty I-D Duty I-D
Lbs 158 338 158 338Shipping Weight Kg 717 1533 717 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
D 25USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom ____
____
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWG bull Maximum vacuum 75 IWG bull Standard motor 50 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
Temperature curves are based on standard model
Legend Pressure Suction
EN808FL5MWL
0
50
100
0 40 80 120 160 200 240 260 300 340 380 420
0 68 136 204 272 340 408 442 510 578 546 714
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 26Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
(8) MTG HOLES
IN OUT
692
850
738 355
1415
709
088
224
111
3
189
1
902
1801
358
909
282
7
480
3
1875
2159
35941758
143
23565984
211
253
7
8752223
8602174 125
318
6751715
117
429
87
185470
3749
15754001
1476
17434427
562 DIA
ROTATIONDIRECTION
FEMALE THREADBOTH PORTS
2 12 - 8 NPSC
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT CONDUIT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN808BA72MXL EN808BA86MXL CP808FY72MXLR
Specification Units 081229 081230 081234
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 75 75 75 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 Motor Nameplate Amps Amps (A) 18693 74 18693 Max Blower Amps Amps (A) 220110 81 220110 Locked Rotor Amps Amps (A) 12663 56 12663 Service Factor - 11 1 11 Starter Size - 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 287 287 287 Kg 1302 1302 1302
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 27Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 85 IWGbull Maximum vacuum 90 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN808 EN808
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 28Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
MTG HOLEDETAIL
(4X)
20 51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
103262
11712974
ROTA
TIO
N
IN OUT
266676
AC
D
B
18414676
105
9 26
90
1806 4587
EN633 181 1894 167 173
MODEL A B C D
EN833 182 1959 180 176
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN833BA72LM CP833FY72LRM
Specification Units 081712 081708
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1995 1995 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Shipping Weight Lbs 297 297 Kg 1347 1347
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 29Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant bull bull Maximum pressure 200195 IWG bull Maximum vacuum 155155 IWG bull Standard motor 75 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions
Inch
es o
fW
ater m
bar
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
60 Hz
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model 0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 30Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
189
5692
1300
817
105
0
218
1
245
675
1096
821
709
1548
1860
481
31758
622
3
554
0
207
526
67
1714
2085
2784
4724
3932
1801
3302
FEMALE THREADBOTH PORTS
191485
13533437
23345928
9462403
9502413
17510752731
MODEL EN858BA72WL
L (INMM)23656007
EN858BD72WL 26006604
L
ROTATION DIRECTION
2 12 NPSC
NOTE 1
OUT IN
445
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN858BD72WL EN858BD86WL EN858BA72WL CP858FZ72WLR
Specification Units 038744 038745 080070 038980
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 100 100 75 100 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 2412 96 18693 2412 Max Blower Amps Amps (A) 3015 116 2613 3015 Locked Rotor Amps Amps (A) 234117 93 12663 234117 Service Factor - 21 1 11 21 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 338 338 326 338 Kg 1533 1533 1479 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 31Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN858D72WLEN858BA72WL
LegendPressureSuction
EN858D72WLEN858BA72WL
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 32Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
834
2118
IN OUT
EN909BG72WL - 038629
FEMALE THREADBOTH PORTS
9502413
24736281
723
185715994031
137348
259
657
9
202
5
15503698
300643
913
231
9
105
266
7
388 11
1
852159
1075
2731
846
21491163520
9062758
MODEL EN909BG72WL
L(INMM)30177663
EN909DB72WL 23666010
L
ROTATION DIRECTION
4 - 8 NPSC
(4) PLACES75 X 200 SLOT
SEE NOTE1
514
4
INMM
PartModel Number
EN909BG72WL EN909BG86WL EN909BD72WL CP909GA72WLR
Specification Units 081741 081736 081743 038982
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 15 15 10 15 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 3618 144 2412 3618 Max Blower Amps Amps (A) 4824 18 3216 4824 Locked Rotor Amps Amps (A) 240120 100 234117 240120 Service Factor - 22 2 21 22 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 524 524 504 524 Kg 2377 2377 2286 2377
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 33Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN909BG72WLEN909BD72WL
LegendPressureSuction
EN909BG72WLEN909BD72WL
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
50
100
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
0
50
100Temperature curves are based on standard model Temperature curves are based on standard model
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 34Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
ROTATIONDIRECTION
4 NPSCPORTS
150 DIA (381)LIFTING LUG
1
9002286
31257938
11382891
5691145
9752477
19254890
8752223 1111
2822
13063317
10372634
25
3264
31
217
755
30
122
531
12
24
762
7
200508
191485
07
619
3NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN979BK72WL EN979BK86WL CP979GB72WLR
Specification Units 080724 082277 081778
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 20 20 20 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 575 230460 Max Blower Amps Amps (A) 4623 184 4623 Locked Rotor Amps Amps (A) 6030 24 6030 Service Factor Amps (A) 334167 118 334167 Starter Size - 32 2 32 Thermal Protection - 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 533 533 533 Kg 2418 2418 2418
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 35Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 90 IWGbull Maximum vacuum 90 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
EN979
LegendPressureSuction
EN979
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 36Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
117
297
4
309
678
638
110027940
16994316426032
1025
3007612
233259239
96424486
44619
OUT IN
1757
96524503
127632410
327
15
243
617
22
86121869
301476556
L
143236373
128
8 153238913
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
INMM
MODEL LENGTH (INMM)EN14BK72MWL 32128159EN14DX72MWL 311857921
PartModel Number
EN14BK72MWL EN14DX72MWL EN14DX86MWL CP14GB72MWLR CP14GC72MWLR
Specification Units 081485 081486 081487 TBD 081491
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 30 30 20 30 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 200-230460 575 230460 200-230460 Max Blower Amps Amps (A) 4623 75-6633 265 4623 75-6633 Locked Rotor Amps Amps (A) 6030 8241 33 6030 8241 Service Factor Amps (A) 294147 448224 226 294147 448224 Starter Size - 32 33 3 32 33 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 601 737 737 601 737 Kg 2726 3343 3343 2726 3343
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 37Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 144 IWGbull
bull Maximum vacuum 115 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 38Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motor-less) Blowers AMETEK Technical amp Industrial Productsrsquo ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial (_RD) Remote Drive Blowers are motorless models built with DRENCPSL blower features and include
Rugged cast-iron arbor and bearing suspension system Oversized shaft to withstand heavy-duty side loads Precision balanced impellers for low vibration operation High speed versions built with heat treated impellers available
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
MF573RD
NOTES1 CONTACT FACTORY FOR PULLEY OPTIONS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
AIR OUT
ROTATION
AIR IN
C
E
B
A
F
D G
Specification INMM
Model Number Part Number A B C D E F G
MF573RD 026940 363 125 658 175 175 175 356 922 318 1671 445 445 445 904
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
10000 RPM
12000 RPM
14000 RPM
10000 RPM12000 RPM
14000 RPM
10000 RPM
12000 RPM14000 RPM
14000 RPM
10000 RPM
12000 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph
0
4
8
Do not exceed maximum speed shown on each graph
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
SL2RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
ROTATION
FLAT
14-20 UNC - 2B X 444 HOLES EQ SPACED ON 443 DIA
N
B
J
K
E
G
F
T
D
C
H
A
PS
Q
L
4 MTG HOLES
4 MTG HOLES(SAME AS OPPOSITE SIDE)
IN OUT
R
Specification INMM
Model Number Part Number A B C D E F G H J K L M N P Q R S T
SL2RD 026125 733 588 992 145 100 500 175 25 175 141 262 175 496 331 300 992 473 100 1862 1494 252 368 254 127 445 64 445 358 665 445 126 841 762 252 12 254
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
AIR AT 1
00˚C
25˚C50˚C75˚C
6000 RPM5500 RPM
5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
6000 RPM5500 RPM
5000 RPM4500 RPM
4000 RPM3500 RPM3000 RPM2500 RPM
6000 RPM5500 RPM5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
25˚C50˚C75˚C
AIR AT 100˚C
6000 RPM5500 RPM
5000 RPM4500 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph or 100degC
0
10
20
Do not exceed maximum speed shown on each graph or 100degC
0
10
2015
05
05
15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 404RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR404RDNT 036439 560 115 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 1422 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
EN404RDML 038334 1276 1150 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 3241 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
75˚CAIR AT 100˚C
50˚C
25˚C
2500 RPM
1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM
25˚C 6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
55004500350025001750
65006500
55004500350025001750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Do not exceed maximum speed shown on each graph or 100degC
01
08
70
Do not exceed maximum speed shown on each graph or 100degC
20
04
40
01
08
70
20
04
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 505RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR505RDNT 036437 568 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 1443 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
EN505RDML 038336 1458 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 3703 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000550045003500
2500
1750
75˚C
AIR AT 100˚C
50˚C
25˚C
2500 RPM1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM25˚C
6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
60005500
450035002500
1750
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC
15
20
10
Do not exceed maximum speed shown on each graph or 100degC
40
08 04
15
20
1040
08 04
Air Flow Rate - SCFM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 513RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR513RDNT 038076 607 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 1542 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
EN513RDL 038341 1190 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 3023 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM
2500 RPM
100˚C75˚C
50˚C
25˚C
60005500
450035002500
60005500
450035002500
2500 RPM
6000 RPM
5500 RPM
3500 RPM
100˚C75˚C
50˚C
25˚C
4500 RPM
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
4
8
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 523RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR523RDNT 037223 796 138 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 2022 3505 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
EN523RDL 038342 138 1555 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 3505 395 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
25˚C
AIR AT 50˚C
45003500250017505500
6000
5500 RPM6000 RPM
25˚C4500 RPM
3500 RPM2500 RPM
1750 RPM
5500 RPM6000 RPM
4500350025001750
55006000
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 230 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 229 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
8
16
0
8
16
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 6Customer Service Fax +1 2152561338 wwwametekdfscom
Dual muers provided in place of muer tower
____
Remote Drive (Motorless) Blowers
DRENCP 6RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR6RDNT 036185 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
EN6RDL 038343 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM1750 RPM
AIR AT 100˚C
50˚C
25˚C
55004500350025001750
2500 RPM 1750 RPM
2500 RPM
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
550045003500
25001750
75˚C
25˚C
50˚C
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 656RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR656RDNT 080610 735 1244 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 1867 3160 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
EN656RDL 080061 1512 146 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 385 3708 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM1750 RPM
100˚C
50˚C
25˚C
600055004500
350025001750
2500 RPM
1750 RPM
2500 RPM
6000 RPM
5500 RPM
4500 RPM
3500 RPM
100˚C
50˚C
600055004500
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
15
30
0
15
30
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 8Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motorless) Blowers
DRENCP 757RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR757RDNT 081847 667 1506 1725 362 25 100 175 505 450 619 644 250 922 640 450 1611 1694 3825 4382 919 64 254 445 128 1143 1572 1636 635 2342 1626 1143 4092
EN757RDML 081848 1506 2023 1725 362 25 100 175 450 505 619 644 250 922 640 450 1611 3825 5138 4382 919 64 254 445 1143 128 1572 1636 635 2342 1626 1143 4092
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
50˚C
5500
450035002500
2500 RPM2500 RPM
5500 RPM
4500 RPM
3500 RPM
5500450035002500
75˚C
50˚C
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
AIR AT 100˚C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 858RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR858RDNT 036413 851 1930 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 2162 4902 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
EN858RDL 038746 1930 2222 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 4902 5644 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4000 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4000
350025001750
75˚C
50˚C25˚C
AIR AT 100˚C
25˚C
4000 RPM
3500 RPM
2500 RPM1750 RPM
4000
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 909RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR909RDNT 081962 853 228 2322 350 500 1375 200 765 500 970 834 301 1297 902 500 198 2167 581 5898 889 127 349 508 194 127 2464 2118 765 3294 2291 127 5029
EN909RDL 081742 228 2451 2322 350 500 1375 200 765 500 970 834 400 1297 902 500 198
5791 6226 5898 889 127 349 508 194 127 2464 2118 1016 3294 2291 127 5029
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4500350025001750
75˚C
50˚C
AIR AT 100˚C
4500 RPM
3500 RPM2500 RPM1750 RPM
4500350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 979RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR979RDNT 080760 105 235 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 2667 5969 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
EN979RDL 080761 235 2517 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 5969 6393 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
3700
350025001750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM2500 RPM
1750 RPM
37003500
25001750
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 1233RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 FILTER 515256 1PIECE
ROTATION
J +- 12
A
Q +- 12E
G +- 25
D
SEEDETAIL AA
DETAIL AA
C +- 06
236599
03910
B
(4X) F
(4X) R
(2X) H
(2X) T
OUTINK +- 12
L +- 12
M +- 25
N +- 25
(2X) PNPSC THD
Specification
Model Number Part Number A B C D E F G J H K L M N P Q R T
DR1233RD 081853 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 669 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 1699 236 348
EN1233RDL 081854 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 689 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 175 236 348
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3500 RPM
2850 RPM
AIR AT 100˚C
50˚C4000 RPM
4300 RPM
40003500
2850
4500400035002850
4300
3500 RPM
2850 RPM
4000 RPM
4500 RPM
75˚C
AIR AT 100˚C
50˚C
75˚C
80 120 160 200 240 280 320 360 400 440 480 520
136 204 272 340 406 476 544 612 680 748 846 884
0
50
100
150
200
250
300
0
100
199
298
398
498
598
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
5
15
25
5
15
25
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS E 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 14RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR14RDNT 081475 987 2224 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 2507 5649 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
EN14RDL 081488 2224 3014 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 5649 7656 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
370035002500
1750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM
2500 RPM1750 RPM
3700
350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
30
60
0
30
60
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 14Customer Service Fax +1 2152561338 wwwametekdfscom
Application Specific Regenerative Blowers Specialty blowers for Commercial Spa High Temperature Natural Gas and Gasoline Vapor Recovery applications
Our industrial NC (NautilairTM Centraxial) blowers include Fiberglass or aluminum housing Aluminum impellers Permanently sealed bearings for 50000 hours life
Our instrument grade and variable flow SE (MinispiralTM Regenerative) blowers include AC and DC versions available for world voltages and maximum flow variability Glass filled molded phenolic impeller aluminum and phenolic case 30000 hour bearing life Small size and lightweight construction
Quiet to NC-47 office equipment standards
Our instrument grade SL (Spiral Regenerative) blowers include Rugged diecast aluminum housing endbells and impellers
Compact size with encased muffler for maximum noise reduction Low amp draw with highly efficient motor
Permanently sealed bearings for 40000 hours life Hermetically sealed models designed for glovebox use
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
111
8032
180 REF
813
4572
44
REF
TYP
411 DIA1044165
4191
Oslash224 DIA
569
210
533
4
416
REF
105
66
212 DIA
1
2
OUT
IN
INMM
PartModel Number
SE2B21 SE62B21 SE2B21A
Specification Units 081901 037395 080694
Phase - Frequency - Single-5060 Hz - Single-5060 Hz Voltage AC 110115 24 110115 RPM RPM 28503400 28503400 28503400 Insulation Class - B B B Full - Load Amps Amps (A) 1714 - 1714 Locked Rotor Amps Amps (A) 1715 - 1715
Shipping Weight Lbs 19 19 19 Kg 09 09 09
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
2 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L mdashdb
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Maximum vacuum 35 IWGbull Maximum ambient 40degC
bull Shaded pole motor with ball bearings
bull B10 bearing life 30000 hoursbull Weight 11 lb (05 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONSbull Sealed unitsbull International voltage and frequency (Hz)
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
LegendPressureSuction
Minispiral
LegendPressureSuction
Minispiral
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
2 leads 20 gaTFE coveredUL style 1180 (12 long stripped 50)
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
44
REF
TYP
111
8
032813
180 REF4572
411 DIA1044
1654191
Oslash224 DIA
569
210
533
4
416
REF
10
566
212 DIA
2
OUT
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12V21 SE24V21
Specification Units 037433 037434
Voltage Range VDC 9-15 24-32 RPM RPM 3600-6000 5500-6800 Insulation Class - B B Full - Load Amps Amps (A) 050-10 06-09
Weight Lbs 086 086 Kg 04 04
WARNING ndash ON MDC MODELEXCEEDING 10 AMP MAY DAMAGE CIRCUIT BOARD
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 70103 IWG (1532 volts)bull Maximum vacuum 70103 IWG (1532 volts)bull Maximum ambient 40degC
amp impellerbull Shaded pole motor with ball bearings
bull B10 bearing life 20000 - 30000 hoursbull Weight 086 lbs (039 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed control
Blower Performance at Standard Conditions12 V-MDC 24 V-MDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
15 V-MDC
12 V-MDC
9 V-MDC
32 V-MDC
26 V-MDC
24 V-MDC
LegendPressureSuction
Minispiral MDC
LegendPressureSuction
Minispiral MDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
BOTH PORTS
057
OD
145
114290
199505
217
552
226
574
116295
02564063
160
092234
054137
083211 0
75 O
D19
1
Oslash1
8346
5
119302
282716
066168
350889
421
106
9
Oslash 4201067
211
536
186
472
057
145
044
112
165419
067170
4071034
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 12
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21 SE24RE21
Specification Units 081548 080847
Voltage Range VDC 75-15 24-32 RPM RPM 4400-8750 4400-8750 Insulation Class - B B Full - Load Amps Amps (A) 12-25 12-16
Weight Lbs 10 10 Kg 05 05
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L db
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull 12 VDC operation 75-15 VDCbull 24 VDC operation 15-32 VDC
bull Maximum pressure 207 IWG (15)bull Maximum vacuum 207 IWG (15)bull Maximum ambient 40degC
amp impellerbull Brushless DC motor with integrated control electronics
bull Stainless steel ball bearings permanently lubricated for B10 bearing life 20000 - 30000 hours
bull Weight 19 lbs (086 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull International voltage and frequency (Hz)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
220 17 34 51 68 85 102 119 136 153
0 1 2 3 4 5 6 7 8 9
20
18
16
14
12
10
8
6
4
2
55
50
45
40
35
30
25
20
15
10
5
15 V-HDC
12 V-HDC
9 V-HDC75 V-HDCLOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
BOTH PORTS
056
ID14
2
106269
192488
217
552
224
569
130330
02564063
160
092234
053135
080203 0
75 O
D19
1 T
YP
Oslash1
750
444
119302
272691
066168
350889
416
REF
10
69
Oslash 4111044
210
5331
8547
00
5614
20
4210
7 R
EF
T
YP
165419
067170
4061031
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 14
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21A
Specification Units 081881
RPM RPM 7397 - 13205 Voltage Range VDC 75 - 15 Insulation Class - B Full - Load Amps Amps (A) 27 - 62
Weight Lbs 25 Kg 11
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOU
ND
PO
WER
LEV
EL
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
EQU
IVA
LEN
T SO
UN
D P
RES
SUR
E LE
VEL
db (r
e 0
0002
mic
roba
r)3
FEET
(09
1 M
ETER
S) F
RO
M N
OIS
E SO
UR
CE
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 26 IWG (15)bull Maximum vacuum 26 IWG (15)bull Maximum ambient 40degC
bull Brushless DC motor with integrated control electronicsbull Stainless steel ball bearings permanently lubricated for B10 bearing life
20000 - 30000 hoursbull Weight 19 lbs (086 kg)bull Compact high performance design 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull Speed sensing output (FPS)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
24
260 17 34 51 68 85 102 119 136 153 170 187 204 221
0 1 2 3 4 5 6 7 8 9 10 11 12 13
22
20
18
16
14
12
10
8
6
4
2
0
50
55
60
65
45
40
35
30
25
20
15
10
5
0
15 V-HDC
12 V-HDC
75 V-HDC
LOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
OUT IN
841
666
412
104
7
445
734
742142
175
OD
331
162
412
587
292
289
3091
1991
100
120 175
254
305 445
1217
300 TYP762
784
1491
25 -20 UNC -2B X 31 DEEP(4 MOUNTING HOLES EACH END)
997
498
263
160
ID
253
2
126
2
406
229582
OPTIONAL OUTLET TRIMMER
OPTIONAL INLET TRIMMER
12 CONDUIT HOLE (1) EACH END
56
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL2P2 SL2P52 SL2P90
Specification Units 036000 036013 036018
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 5 5 5 Voltage AC 115 208-230 380460 Phase - Frequency - Single-5060 Hz Single 60 Hz Three-5060 Hz Insulation Class - B B B Full - Load Amps Amps (A) 245360 95154 3441 Service Factor - 10 10 10 Locked Rotor Amps NEMA Amps (A) 100 43 19 Starter Size - 0000 0000 0000
Shipping Weight Lbs 27 27 27 Kg 122 122 122
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum vacuum 313 IWGbull Standard motor 05 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL2 Spiral SL2
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
656 MAX1666
7211831
12rdquo CONDUIT HOLE(1) EACH END
IN
OUT
1524600
130
3 M
AX
331
997
253
2
300 TYP762
924
5761463
2347
412
104
7
412
162
138351
292
287729
317805
25-20 UNC-2B X 31 DEEP(6) MOUNTING HOLES EACH END742
160
ID
175
OD
445
406
666
262
989
DIA
251
2
456 MAX1158
CAPACITORS ON SINGLEPHASE MODELS ONLY
PartModel Number
SL4P2 SL4P52
Specification Units 036009 036027
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 370380 229220 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 60 IWGbull Maximum vacuum 558 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL4 Spiral SL4
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
IN
OUT
762
1831
331
805729
742351
412
666
PHASE MODELS ONLY
(6) MOUNTING HOLES EACH END
(1) EACH END
6001524
1666656 MAX
721
130
3 M
AX
300 TYP
412 162
175
OD
138 292
287 317
104
7
445
456 MAX1158
262997
253
2
9242347
5761463
160
ID
40
6
989
DIA
25
12
CAPACITORS ON SINGLE
25-20 UNC-2B X 31 DEEP
12 CONDUIT HOLE
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL5P2 SL5P52
Specification Units 036010 036261
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 458675 185255 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 31 IWGbull Maximum vacuum 313 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL5 Spiral SL5
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
0
15
30
45
60
75
90
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
0
15
30
45
60
75
90
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
AB
B
CX
W
R S
L
F
PU
M N O11
3 (2
869
6)
J
(4X) MTG HOLES028 DIA
KG
VZ
T
250 (6350)AA
Oslash40HOLE (4X)
175 (4445)35 (8890)
TEFC MODEL
D (R
EF)
538
(136
65)
E
Y
Oslash5
19 (1
318
3)
495 (1257)
495 (1257)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
CX
W
Oslash769 (19528)
R S
L
P (DIA INLET)F
U
M N O
J
(4X) MTG HOLES028 DIA
KG
VZ
H (TYP)
T253 (6431)
HOLES FOR ELECTRICAL CONNECTIONS
14-20 UNC-2B X 50 DP(4) MTG HOLES EQUALLYSPACED ON A 3625 DIA BC
14-20 UNC-2B X 50 DP(4) MTG HOLES
175 (4445)350 (8890)
STANDARD MODEL
D3
49 (8
875
)
123
(31
35)
E
Y
150 (3810)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
R
S
T
U
V
W
X
Y
Z
AA
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
197(50)
278(706)
726(1844)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
NC33AG58(XP)
NC33AE9(TEFC)
NC33A(STD)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
420(1067)
278(706)
1394(3541)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
352(894)
278(706)
1335(3391)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)713
(1811)
PartModel Number
NC33A2G NC33A3G NC33A33G NC33AE9 NC33AG58
Specification Units 037791 037792 037793 080114 080113
Phase - Frequency - Single-5060 Hz Single-5060 Hz Three-5060 Hz Single-5060 Hz Single-5060 Hz Voltage AC 115 220230 208-230 115230 115230 RPM on 5060 Hz - 29003500 29003500 29003500 29003500 29003500 Insulation Class - B B B F F Full - Load Amps Amps (A) 344384 147182 110118 6030 44 Locked Rotor Amps Amps (A) 825 40 50 21105 3819
Shipping Weight Lbs 18 18 18 28 30 Kg 82 82 82 127 136
Motor Enclosure - Standard Standard Standard TEFC XP
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
80
70
60
50
40
90
80
70
60
50
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
SOUN
D PO
WER
LEVE
L ndashdb
(re
10
Wat
ts)
2075
75150
150300
300600
6001200
12002400
24004800
480010000
OCTAVE BAND CENTER FREQUENCY Hz
-12
NC33
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Thermoset plastic blower housing with aluminum impellerbull Permanently seal ball bearings in motor - L10 bearing life 50000 hoursbull Quiet operation within OSHA standardsbull Shipping weight 18 lbs (82 kg) for standard model
28 lbs (127 kg) for TEFC model30 lbs (136 kg) for XP model
bull Designed for UL and CSAbull Automatic thermal overload protection on standard motor enclosures
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
LegendPressureSuction
LegendPressureSuction
NC33 NC33
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
G650
165
1
B
C
E042107
1021259
LF
I HA
J
D
(4) MTGHOLES
THREAD
THREAD
MODEL
DR404AQ58M
DR454V58
DR505AW58M
DR513V58
DR656K58X
A (INMM) B (INMM) C (INMM) D (INMM) E (INMM) F (INMM) G (INMM) H (INMM) I (INMM) J (INMM) K (INMM) L (INMM)
8932268 1012257
4751207
4751207 192488 6281595 1152921 12163089 30762 375953 12883722 5915 12913279
225572 7461895 15423917 15173853 4141052 551397 15123841 5915 15513939
4751207
10302616 11382891 192488 6981773 12553188 325826 4501143 10812746 5915 1445367
10302616 11702972 187475 7261844 13533437
13523434
14383653 356927 4501143 14383653 5915 150381
114229014751207 223566 8692207 14213609 1584013 372945 5501397 1374349 5915 14583703
492125 11422901 1283251
1303302
12-14 NPSM
T-BOX
GND LUG
P DIA
2- NPSC
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY
FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL
LENGTHS NOT SHOWN
INMM
PartModel Number
DR404AQ58M DR454V58M DR505AW58M DR513V58 DR656K58X
Specification Units 037778 080485 037935 038143 080603
Motor Enclosure - Shaft Mtl - SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS TEFC-CS Horsepower - 10 15 20 15 30 Voltage AC 115230 115230 115230 115230 115230 Phase - Frequency - Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 1575 15276 21105 15276 31155 Service Factor - 14 13 12 13 10 Maximum Blower Amps Amps (A) 84 1785 2613 1785 278139 Locked Rotor Amps Amps (A) 3216 8543 13668 8543 200100 Recommended NEMA Starter Size- 000 10 10 10 151
Shipping Weight Lbs 64 76 83 90 51 Kg 29 345 376 408 231
Recommended Number of Jets - 3-6 5-10 5-10 12-17 8-12
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
Notes- The blower should not be stoppedstarted more than four times an hour - Use of relief valve 515092 is required for all blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 56 58 74 69 or 88 IWGbull Standard motor 10 15 20 30 HP Spa Duty ODP
(threaded)bull
Class B rated thermal protectionbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull Variable frequency drive package
UL amp CSA approved motor with permanently sealed ball bearings and
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
DR404DR454DR505DR513DR656
LegendPressureSuction
DR404DR454DR505DR513DR656
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
100
200
0
100
200
0
100
200
0
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
PartModel Number
DR10RDNT SS10RDNT HS10RDNT
Specification Units 036594
Shaft Material - Carbon Steel Stainless Steel Hastelloy Speed Range - 1750-4500 1750-4500 1750-4500 Housing Cover Cover - Cast Iron Stainless Steel Hastelloy
Shipping Weight Lbs 400 500 600 Kg 1814 2268 2722
SS = Stainless Steel HS = Hastelloy
1 DR10RDNT not recommended for use with explosive gas due to material of construction
2
3
4
Maximum operating temperature Blower outlet air temperature should not exceed 260degC (air temperature rise plus inlet temperature)Contact factory for use above 260degC blower outlet air temperature
AMETEK will not be liable for blowers operated beyond factory specic RPM
All applications must be reviewed Contact application engineering for assistance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
bull Packaged on baseplate with V-belts or coupling guard amp motorbull High temperature Vitonreg sealsbull Krytoxreg grease high temperature bearings
PACKAGEMOTOR OPTIONSbull International voltage amp frequency (Hz)
bull Packing gland or double faced seal options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Variable frequency drive package
Note For accessories special high temperature models may be required
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
20
40
0
20
40
AIR T 100 ordmC
75 ordmC
50 ordmC
4500 RPM3500 RPM2500 RPM
1750 RPM
4500
3500
25001750
AIR T 100 ordm C
75 ordm C
50 ordm C
4500 RPM3500 RPM
2500 RPM
1750 RPM
4500
3500
25001750
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
Rev 204
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
MD101CB4 MODEL SHOWNTEFC MOTOR
MD101CC4 MODEL SHOWNXP MOTOR
Oslash9
8424
99
249
9
188478
478
169429
429
4121047
1047
1500381
6001524
1524
RESET BUTTONOslash 87 CONDUIT HOLE
22
350889
889
300
762
762
262
665
665
OUTLET INLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE71
71
Oslash9
84
188
169
8252096
412
1664216
600
LEADS FAR SIDE
350
300
262
OUTLETINLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE
75-14 NPT
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
ROTATION
ROTATION
PartModel Number
MD101CB4 MD101CC4
Specification Units 038014 038271
Motor Enclosure - Shaft Mtl - TEFC Explosion-proof Horsepower - 25 25 Phase - Frequency Voltage - Single-60 hz Single-60 hz Motor Nameplate Amps AC 115 115 Max Blower Amps Amps (A) 26 26 Locked Rotor Amps Amps (A) 22 22 Service Factor Amps (A) 64 72 Starter Size - 10 10 Thermal Protection - 00 00 XP Motor Class - Group - Class B - Automatic Manual Reset Class B - Automatic
- - I-D
Shipping Weight Lbs 40 40 Kg 181 181
F 21
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
FEATURESbull Hermetically designed seal-less blowerbull Continuous operationbull Manufactured in the USA
bull Maximum pressure 28 IWGbull Maximum vacuum 265 IWGbull Standard motor 025 HP TEFC or XPbull Disconnect motor without disassembling from piping
bull Permanently sealed ball bearings in housing and motorbull Quiet operation within OSHA standards
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
AIRSG = 10
NATURAL GASSG = 056
NATURAL GASSG = 056
AIRSG = 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 GVR313AK4H MODELS SHOWN
10502667
ROTA
TIO
N
375
953
14193604
113
8 (T
YP)
289
1
1 12 NPTF (2) PLACES (GVR313)
22559
4001016
IN OUT
68751746
421067
348688
224 49
124
5
65
165
1
BOTTOM VIEW
INMM
PartModel Number
GVR313AK4H GVR313AK58H GVR313AK72HA GVR313AK91H GVR313AE4HA
Specification Units 038584 081531 081470 081524 080274
Motor Enclosure - Shaft Mtl - Explosion-proof - CS Explosion proof - CS Explosion proof - CS ATEX - CS TEFC Horsepower - 05 05 05 075 05 Phase - Frequency Voltage - Single-60 hz Single-5060 Hz Three-60 Hz Three-50 Hz Single-60 Hz Motor Nameplate Amps AC 115 110220 230460 400 115 Max Blower Amps Amps (A) 94 8442 1407 14 74 Locked Rotor Amps Amps (A) 76 6834 1407 11 74 Service Factor Amps (A) 45 45 10251 9 47 Starter Size - 10 10 115 10 10 Thermal Protection - 0 0 00 0 0 XP Motor Class - Group - Class B - Automatic Class B - Automatic Class B - Automatic Thermistors Class B - Automatic
- I-D 1-D 1-D EExd IIB 1-D
Shipping Weight Lbs 39 39 39 45 39 Kg 177 177 177 204 177
1 115 voltage 1 phase motors are standard 230 volt motors available As an option a transformer could be used2 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors
or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
Rev 204
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
FEATURESbull Manufactured in the USA
bull Maximum pressure 45 IWG bull Maximum vacuum 408 IWGbull Standard motor 05 HP TEFCbull Anodized cast aluminum blower housing impeller amp cover
bull Quiet operation within OSHA standardbull ROHS gold irridite coatings on aluminum surfaces
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONS
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
GVR313
GVR313
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 24Customer Service Fax +1 2152561338 wwwametekdfscom
Accessories AMETEK Dynamic Fluid Solutions ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our accessories for regenerative blowers inlude
Filtration Accessories Measurement Accessories Noise Reduction Accessories Valves and Gauges
VFD Drives Air Knives
Blower Model Reference Key A = SPIRAL E = DRENCP656 6 633 S7 B= DRENCP068 083 101 202 F = DRENCP 757 808 858 S9 P9 (Inlet Only) C= DRENCP303 312 313 353 G= DRENCP833 S13 P13 (Inlet Only) D = DRENCP404 454 513 505 555 523 H = DRENCP909 979 1233 14 S15 P15 (Inlet Only)
Blower Connection Key NPTndash American National Standard Taper Pipe Thread (Male) NPSCndashAmerican National Standard Straight Pipe Thread for Coupling (Female) SO ndash Slip On (Smooth ndash No Threads)
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inlet Filter (Single Connection)
Inlet Filters protect the blower and the air distributionsystem from dust and other airborne particles andcontaminants Normally used in pressure systems
A
Oslash
B
C Oslash
SPECIFICATIONS HOUSING ndash Steel MEDIA ndash Polyester EFFICIENCY ndash 97-98 (8 to 10 micron particle size) FILTER ELEMENT ndash Replaceable (see filter elements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particle size) available
PartModel Number
Specification Units 477411 516466 515122 515123 515124 515125 515145 515151 516511
Filter Element - A B C D E E F G H H Ref Blower Model - 271078 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 200 SO 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 456 600 600 775 1000 1000 1000 1000 1600 mm 1158 1524 1524 1969 254 254 254 254 4064
Dimension B Inches 612 650 650 725 1225 1250 1300 1400 1500 mm 1554 1651 1651 1842 3112 3175 3302 3556 381
Dimension C Inches 200 100 15 200 200 250 300 400 600 mm 508 254 381 508 508 635 762 1016 1524
Z Media Filter PN - 517865 517866 517867 517868 517869 517870 517871 517872
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 11258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inline Filter (Dual Connection)
Inline Filters protect the blower from harmful dustand other particles that may be drawn into theblower through the air distribution systemNormally used in vacuum systems
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron particle size)FILTER ELEMENT ndash Replaceable (see filterelements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particlesize) available Feature 14 threaded tap for gauge connection on inlet and outlet
Inline lter PN 271200 is a straight through designInlet is directly opposite of outlet
D DIA
B
A
C DIA
PartModel Number
Specification Units 271200 516461 515254 515255 515256 516463 516465 517611
Filter Element - 271078 516434 516434 516435 516435 515135 515135 516515 Ref Blower Model - A B C D E F G H H Inlet Connection - 175 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M Outlet Connection - 200 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M
Dimension A Inches 525 725 700 800 800 1400 1400 1800 mm 1334 1842 1778 2032 2032 3556 3556 4572
Dimension B Inches 831 650 650 1025 1025 2650 2700 2800 mm 2111 1651 1651 2604 2604 6731 6858 7112
Dimension C Inches 200 100 150 200 250 300 400 600 mm 508 254 381 508 635 762 1016 1524
Dimension D Inches 175 100 150 200 250 300 400 600 mm 445 254 381 508 635 762 1016 1524
Z Media Filter PN - 517886 517887 517888 517889 517890 517891 517892
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Silencers (Single Connection)
FilterSilencers reduce noise levels whileensuring clean air is provided to the blower andthe air distribution system Normally used inpressure applications
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron size)FILTER ELEMENT ndash Replaceable (see filter elements)
A
Oslash
B
C
Oslash
PartModel Number
Specification Units 516487 516489 516491 516493 516495 516497 516499 516513
Filter Element - B C D E E F G H H Ref Blower Model - 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 600 600 1000 1000 1000 1000 1233 1600 mm 1524 1524 254 254 254 254 313 4064
Dimension B Inches 650 650 725 1225 1250 1250 1387 1500 mm 1651 1651 1842 3112 3175 3175 352 381
Z Media Filter PN - 517878 517879 517880 517881 517882 517883 517884 517885
Dimension C Inches 100 150 200 200 250 300 400 600 mm 131541012 131541266 13154152 131541774 131542028 131542282 131542536 13154279
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 31258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Element
All ROTRON Air Filters and FilterSilencers have replaceable filter elements The filter media is polyester designed for high efficiency over a wide spectrum of industrial applications See yumllter element cross reference table Filter elements supplied with foam pre-filter
Standard Replacement Filter Element Cross Reference Table
271200 271078 515158 515134 516489 515132477411 271078 515254 516434 516491 515133515122 515132 515255 516435 516493 515134
515123 515133 515256 516435 516495 515134515124 515134 516461 516434 516497 515134515125 515134 516463 515135 516499 515135
515145 515134 516465 515135 516511 516515515151 515135 516466 515132 516513 516515515157 515133 516487 515132 517611 516515
HT
For DR Blower Models
OslashID
OslashOD
Filter Filter FilterElement Element Element
PartModel Number
Specification Units 515132 515133 515134 515135 516434 516435 516515
Z Media Filter PN - 517873 517874 517875 517876 517893 517894 517877
Dimension ID Inches 300 363 35 475 256 350 800 mm 762 922 889 1207 65 889 2032
Dimension OD Inches 438 588 588 788 500 588 1175 mm 1113 1494 1494 2002 127 1494 2985
Area SqFt 475 475 950 963 475 875 963 SqM 0 0 1 1 0 1 1
Dimension HT Inches 15 23 45 83 20 45 190 mm 381 584 1143 2108 508 1143 4826
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 41258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
By separating and containing entrained liquidsROTRONrsquoStrade moisture separator helps protect our regenerative blowers and the end treatment systemfrom corrosion and mineralization damage Recommended for all soil vacuum extraction Applications
applications
PLASTIC ldquoPrdquo DESIGN METAL ldquoDrdquo DESIGN METAL ldquoBrdquo DESIGN
SPECIFICATIONSSEPARATION METHOD ndash High Effciency Cyclonic RELIEF VALVE MATERIAL ndash Brass amp Stainless SteelFLOAT MATERIAL ndash CopperFLOAT SWITCH ndash SPDT Explosion-proof
NEMA 7amp9 5 Amp max
(OPTIONAL)
VALVE
(OPTIONAL)
ODINLET
(PLUGGED) SWITCH(OPTIONAL)
G
D
H
H
(PLUGGED)
C
J
B
34NPT
CAPACITY(PER CHART)
EF
390
(OPT
ION
AL
LOW
SW
ITCH
)
SWITCH(OPTIONAL)
INLET
H
B
DJ
E
F
(OPTIONAL)
(PLUGGED)
B
VALVE
(OPTIONAL)
J
D
C
E F
G
VALVE
34NPT
INLETOD
FLOAT SWITCH
34 NPT
VACUUM RELIEF
VACUUM GAUGE
14 NPT FLOAT LEVEL 14 NPT
DRAIN
WATER LEVEL
DRAIN - 1 NPT INTERNAL THD
FLOAT LEVEL
OD
VACUUM GAUGE
14 NPT
VACUUM RELIEF
VACUUM GAUGE
VACUUM RELIEF
DRAIN
TMMOISTURE SEPARATOR
RAP AT ORI SO T U R E
EM
S
A
A
INSTALL FLOAT SW
INFO PACKET
MOISTURE SEPARATOR
TM CYCLONICACTIONCAUTIONFREEZING MAY CAUSE DAMAGEMOISTURE SEPARATORS USED IN TEMPERATURES BELOW 32oslashF (0oslashC)MUST BE PROPERLY WINTERIZED
A
T ORURE
G
OUTLETOUTLET
OUTLET
PartModel Number
MS200PS MS300PS MS350BS MS500BS MS600BS MS1000BS
Specification Units 038519 038520 038357 080660 080659 038914
Dimension A Inches mm
238 605
288 732
325 826
325 826
400 1016
600 1524
CFM Max CFM m3hr
200 340
300 510
350 595
500 850
600 1020
1000 1700
Dimension B Inches mm
2246 5705
2246 5705
2800 7112
2800 7112
2700 6858
3100 7874
Dimension C Inches mm
1600 4064
1600 4064
2300 5842
2300 5842
2300 5842
2700 6858
Dimension D Inches mm
325 826
325 826
400 1016
400 1016
400 1016
400 1016
Dimension E Inches mm
3105 7887
3105 7887
3725 9462
3737 9492
3737 9492
4732 12019
Dimension F Inches mm
3330 8458
3330 8458
3950 10033
5450 13843
5450 13843
5170 13132
Dimension H Inches mm
6 1524
600 1524
975 2477
975 2477
925 235
1000 254
Dimension G Inches mm
450 OD 1143
450 D 1143
450 OD 1143
663 ID 1684
663 ID 1684
862 OD 2189
Dimension J Inches mm
1325 3366
1325 3366
1750 4445
1750 4445
1750 4445
1988 505
Drain Internal Thd - 34 34 1 1 1 1
Shipping Weight Lbs Kg
42 191
42 191
82 372
95 431
96 435
150 68
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
404
ForDRENCP
BlowerModel
SelectorMoistureSeparator
Model
Liquid-holdingCapacity(gallons)
Inlet(OD)
Outlet
MaxVacuum
Allow(IHG)
454
MS200PS 7 238 12
45 OD
MS300PS 7 288
MS350BS
MS500BS 40325
MS600BS 40663 ID 22
MS1000BS
Pre
ssur
e D
rop
(IWG
)
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
1
2
3
4
5
6
Flow Rate (SCFM)
65 60 862 OD
505513523555633833656
6757808
909
8581233
97914
The moisture separator shall be designed for use in a soil vapor extraction system capable of continuous operation with a pressure drop of less than six inches of water at the rated ow of _____ SCFM The separator shall be capable of operation under various inlet conditions randing from a ne mist to slugs of water with high eciency
The moisture separator shall incorporate cyclonic separation to remove entrained water The separator must protect against an overow by fail safe mechanical means An electrical switch or contact(s) alone is not an acceptable means of protection against overow but is a good backup
The body of the moisture separator shall be constructed of heavy wall plastic or heavy gauge cold rolled steel The steel interior and exterior shall be epoxy (powder) coated to resist abrasion corrosion and chipping that might expose the surface The inlet shall be tangentially located and welded to the body The outlet port shall be constructed of PVC or cast aluminum alloy anged and sealed to the center of the top of the separator The separator shall incorporate a non-sparking copper oat ball and an adjustable relief valve to protect against overow and overheating the blower
The moisture separator must have a liquid capacity of _____ gallons The inlet shall be _____ inch OD slip-on type The outlet shall be _____ inch OD slip-on type
20 Moisture SeparatorTM Specications
21 Duty
22 Principle of Operation
23 Construction
24 Capacity and Dimension
25 Pressure Drop
MS2
00PS
MS3
00PS
MS3
50BS
MS5
00BS
MS6
00BS
MS1000
BS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
FEATURESbull Direct reading in SCFMbull Low pressure drop (2-4 typical) across
the flow meterbull Non-clogging low impedance air streambull Light weight aluminumbull No moving partsbull Large easy-to-read dialbull Accurate within 2 at standard conditionsbull Good repeatabilitybull Available in 2 3 and 4 sizesbull Factory conyumlgured for quick installationbull 048 Allen key supplied for gauge adjustment
OPTIONSbull Corrosion-resistant version with Chem-Tough
trade or in stainless steelbull FDA-approved Food Toughtrade surface conversion
BENEFITS
bull OPTIMIZE SYSTEM EFFICIENCY Measuring the correct air ˜ow canassist you in yumlne-tuning to yoursystemrsquos optimal efficiency
bull BALANCE MULTI-PIPING SYSTEMSWhen evacuating CFM from more than onepipe di˝erent run lengths or end systemimpedance can cause one pipe to handlemore CFM than the other With an accurateCFM reading piping can be balanced bybleeding air inout or by creating an extraimpedance
bull DETECT CHANNELING OR PLUGGINGFor systems in which channeling orplugging can occur a change in the CFMmeasured can help indicate the unseenchanges in your system
PartModel Number
FM20C030Q FM20C045Q FM20C065Q FM20C125Q FM20C175Q FM20C225Q
Specification Units 550599 550600 550601 550602 550603 550604
Flow Rate CFM 6-30 9-45 13-65 25-125 35-175 45-225 m3hr 10-50 15-77 22-111 43-213 60-300 77-383
Threads B - 2-115 2-115 2-115 2-115 2-115 2-115
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
PartModel Number
FM30C250Q FM30C350Q FM30C475Q FM40C450Q FM40C600Q FM40C850Q
Specification Units 550605 550606 550607 550608 550609 550610
Flow Rate CFM 50-250 70-350 95-475 90-450 120-600 170-850 m3hr 85-425 119-595 162-808 153-795 204-1020 289-1445
Threads B - 3-8 3-8 3-8 4-8 4-8 4-8
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
HOW IT WORKSHIGH TEMPERATURE PRESSURE CORRECTION
TYPICAL FLOW METER ARRANGEMENT
ROTRONrsquoS ˜ flow meter is a venturi style designAfter air enters the inlet the pressure ismeasured in the P1 tap The second tap P2measures the pressure at the throat Thedifferential between P1 and P2 registers across a special calibrated CFM gauge to provideaccurate readings The throat is then expandedback to the original size to keep pressure loss tounder2-4 IWG
SCFM 1SCFM 2 =
147 x 530Pf2 Tf2 + 460radic( ) ( )
Pf 2 = Absolute Pressure inPSIA Tf2 = Temperature in degF
bull Use on inlet to limit need to correct for highpressure or elevated outlet temperature
bull Standard model limits = 140degF and 30 PSIG
TYPICAL GAUGE FACE
REGENERATIVE BLOWER GROUP
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
FLOW DIRECTION
375
375
20
287DIA
556
175
35REGENERATIVE BLOWER GROUP
C
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
B
OslashF
TMMOISTURE SEPARATOR
R A PATORIS OTURE
EM
S
BLOWER
INLET FLOWMETER SYSTEM UNDER VACUUM
SYSTEM PIPING
P RE S SUR E 3 0
P S I GXAM
014070
210 280
350
MINIHELIC II
AMETEKROTRON TIPTECHNICAL amp INDUSTRIAL PRODUCTS
IN OUT
P1 P2
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Digital Flowmeter
316
187
3583
3780
1 2 3 4
2596
275
48114
350 100
Oslash16 (2X)MOUNT HOLES
OUT
LOW
HIGH
-COM
+EXC
189 169
551
Remote air flow rate monitoring and system automation control can now be achieved through the use of 4-20 mA output signalsOur 4-20 mA analog outputs are proportional to system flow rates and can be used with PLC controlled operations to monitorsystem performance Those same outputs provide digital displays for direct readings in SCFM when paired with our LCD DigitalReadout option Combined with our Variable Frequency Drives you can now achieve a completely automated system capable ofadjusting blower performance to meet changing system demands Maintaining your system at peak performance gives yourcompany the competitive edge needed in todayrsquos marketplace
FM20S030Q FM20S045Q FM20S065Q FM20S125Q FM20S175Q FM20S225Q FM30S250Q FM30S350Q FM30S475Q FM40S450Q FM40S600Q FM40S850Q 550838 550839 550840 550841 550842 550843 550844 550845 550846 550847 550848 550849
LCD DISPLAYFM20L030Q FM20L045Q FM20L065Q FM20L125Q FM20L175Q FM20L225Q FM30L250Q FM30L350Q FM30L475Q FM40L450Q FM40L600Q FM40L850Q 550860 550861 550862 550863 550864 550865 550866 550867 550868 550869 550870 550871
DIFFERENTIAL PRESSURE TRANSMITTER 4-20 mA signal output control signals provide flow rate monitoring capabilities from remote locations NEMA 1R-raintight enclosure orotects the integrated DC power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter Weight 3 lbs Signal Output 4-20 mA DC1
HiLo pressure fittings feature snap lock action to unsure trouble-free connections2
System includes standard flowmeter for on-site readings and troubleshooting Operating temperature 0oF to 150oF Drawing available
LCD DIGITAL READOUT OPTIONS Factory configured to display direct readings in SCFM to a remote location up to 50 from signal output1 NEMA 4 IP65 enclosure ready for panel mount instlation power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter installation Power input 120 VAC 5060Hz AC Field configurable to 240VAC Display 5 digit 7 segment 5 high LED w33Hz update rate Operating temperature 10oC to 40oC Weight 1lb 14oz
Drawing available Note 1 4-20 mA output control wiring to be customer supplies Shielded 2 conductor cables 22 AWG is recommemeded for runs up to 100 For longer runs contact factory
Note 2 Use 516 OD stiff wall tubing-connect Lo on flowmeter to Lo on 4-20 mA enclosure Hi on flowmeter to Hi on 4-20 mA enclosure Tubing must be equal in length (Maximum length is 1o feet)
DIFFERENTIAL PRESSURE TRANSMITTER
USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 9Customer Service Fax +1 2152561338 wwwametekdfscom
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
____
Accessories
Noise Reduction - Sound Attenuating Enclosure
Frameless sound attenuating enclosures are a proven way to reduce regeenrative blower mechanical noise when additional mufflers are just not enough Additional enclosure options are available
FEATURESExcellent noise reduction (~10DbA)Resistance to elements and aesthetic appearanceCompact size for ease of installationEasy access for routine maintenance (removable foor and sidewalls)
SPECIFICATIONS Roof floor and walls galvanized 16 ga carbon steel sheet metal Louvers andor hood Riveted aluminum Hardware Chrome plated aluminum handles with stainless steel fastners Latches Over center glvanized with adjustable tension and padlock eye Sound attenuating material 2 rigid polyester foam with mylar facing (rated UL-94) Exterior finish Polyurethane enamel
3000
5000
4600
LIFTING HOLE(PLUGGED)TWO (2) PER SIDE(TOTAL 4)
950
950
END SECTION
END SECTION3100 CLEAR
1500
18 FANASSEMBLY
200 200
2600 CLEAR
Enclosure ventilation 13 HP 230460V 3-phase or 1-phase 5060Hz fan TEFC or XP motors Fan Guard Nickel plated wire type
PartModel Number
SAE30W72F SAE36W72F
Specification Units 552904 552905
Width Inches 30 36 mm 762 9144
Blower Size - 656 707 757 808 858 909 979 P9 S9 14 P13 S13 P15 S15
Height Inches 46 52 mm 11684 13208
Length Inches 50 60 mm 1270 1524
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - InletOutlet Muffler (Single Connection)
Muers lower blower noise in areas where reduced sound levels are required
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
D
C
B
A
PartModel Number
Specification Units 523627 523626 523625 523624 523623 523622
Ref Blower Model - B C D E E E Inlet Connection - 10 NPT Male 125 NPT Male 150 NPT Male 200 NPT Male 200 NPSC Female 200 NPT Male
Dimension A Inches 400 400 400 400 400 400 mm 1016 1016 1016 1016 1016 1016
Dimension B Inches 1093 1093 1093 1093 1093 1575 mm 2776 2776 2776 2776 2776 4001
Dimension C Inches 1398 1407 1457 1216 1243 1695 mm 3551 3574 3701 3089 3157 4305
Dimension D Inches 100 125 150 200 200 200 mm 254 318 381 508 508 508
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - Inline Muffler (Dual Connection)
Inline Muers are utilized for noise reduction inapplications where piping systems are connected directlyto both ends of the muer Muer may be used on inletor outlet of blower
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
C
B
A OUTLETCONNECTION
INLETCONNECTION
PartModel Number
Specification Units 550888 522948 529900 551377 515185 511569 515210 551565 516264
Ref Blower Model - D E E E F G G G H Inlet Connection - 15 NPT-M 20 NPT-M 20 NPSC-F 20 NPT-M 25 NPT-M 30 NPT-M 40 NPT-M 40 NPT-M 40 NPT-M Outlet Connection - 20 NPT-F 20 NPSC-F 20 NPSC-F 20 NPT-M 25 NPT-F 30 NPT-F 40 NPT-F 40 NPT-M 40 NPT-F
Dimension A Inches 400 400 438 400 612 700 1000 1000 800 mm 1016 1016 1113 1016 1554 1778 254 254 2032
Dimension B Inches 775 1575 1575 1575 1500 1800 2400 2400 2200 mm 1969 4001 4001 4001 381 4572 6096 6096 5588
Dimension C Inches 155 1845 1845 1815 1900 2225 3000 3000 2775 mm 3937 4686 4686 461 4826 5652 762 762 7049
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Relief Valve - Mechanical
Part Model Number
Specification Units 551026 551027 523230
Ref Blower Model - B C D D E F A B C D E F
Range in H2O mbar
20-180 498-4484
415-263 1034-6551
35-90 872-2242
Connection - 1 12 2 Description - Mechanical Mechanical
2 Mechanical Vacuum Only
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS G 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Pressure Regulating Diaphram Valve
PRESSURE RELIEF B is the system port and A is the vent or atmospheric port
VACUUM RELIEF A is the system port and B is the vent or atmospheric port For vacuum mode customer must remove snap ring and screen
NOTE Replace cap after adjusting setting Valve will not operate with cap removed Differential adjustment screw is under the cap
Fig 1 Fig 2
NOTE Blower Model P13 requires two 515093 relief valves
The PRD Valve is installed to prevent excessivesystem pressure or vacuum that could result fromline restrictions Valves should be installed at theblower outlet (downstream) in pressure systemsand at blower inlet (upstream) in vacuum systemsThese valves are suitable for air natural gaspropane and other non-corrosive service
Note PRD valves are not factory preset but areeasily field adjustable
SPECIFICATIONSVALVE BODY ndash Aluminum (1) CastIron (2) VALVE SPRING ndash SteelDIAPHRAGM ndash Nitrile
D
C
DIFFERENTIALADJUSTMENTSCREW
A
BGAUGEPORT
SEENOTE
GAUGEPORT
A
B
D
C
PartModel Number
Specification Units 515092 529612 529857 529858 551130 515093 529859 550246 550247
Range in H2O 27-125 110-415 277-554 7-18 14-62 48-194 110-277 97-197 97-194 mbar 673-3114 274-10338 690-1380 174-448 349-1544 1196-4833 274-690 2416-4907 2416-4833
Description - Fig 1 Fig 1 Fig 1 Fig 2 Fig 2 Fig 2 Fig 2 Pressure Vacuum Ref Blower Model - B C D E B C D E B C D E F G F G F G F G H H Inlet Connection - 1 1 1 2 2 2 2 25 25 Outlet Connection - 1 1 1 2 2 2 2 25 25
Dimension A Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension B Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension C Inches 412 412 412 712 712 712 712 619 619 mm 1046 1046 1046 1808 1808 1808 1808 1572 1572
Dimension D Inches 870 870 870 900 900 900 900 765 765 mm 221 221 221 2286 2286 2286 2286 1943 1943
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Gauges
ROTRON has a variety of gauges for pressurevacuum and temperature measurements invarious ranges These gauges are reliable andrugged
SPECIFICATIONS
Pressure Vacuum TemperatureCASE ndash Drawn Steel Finished CASE ndash Steel
LENS ndash GlassACCURACYndash 1
in Black EnamelDIAPHRAGM ndashBronze LENS ndash ClearPlastic ACCURACYndash2WEIGHT ndash 12 lbCONNECTION ndash 14NPT FACE ndash 2 12 dia
WEIGHT ndash 14 lbCONNECTION ndash 12NPT FACE ndash 3 Dial
Pressure Vacuum
Temperature
200
180
160
140
120100
80
60
40
20
100
50
150
200 250
350
400
300
degF
degC
10
0
1
2
3
4
5
6
PRESSURE
0
2040
60
80 100
120140
160
P S INCHE S OF WAT E RI
25 plusmn03Oslash 318 plusmn12
250 plusmn06
338 plusmn12
12 NPT CONNECTION
PartModel Number
Specification Units 551376 271949 529428 271950 551368
Range - Pressure Pressure Vacuum Vacuum Temperature Description - 0-60 IWG 0-160 IWG 0-60 IWG 0-160 IWG 0-200 Deg C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Variable Frequency Drive
A Variable Frequency Drive (VFD) is an adjustable speed AC motor control designed to speed the blower RPM up or down Our VFDs are designed to minimize losses and deliver increased efficiency low maintenance and the long life expected from the ROTRON product line
FEATURESbull
ncy by controlling motor RPMsbull Accepts 3Oslash or 1Oslash inputs to drive 3Oslash motor blower
assembliesbull Accepts 4-20 mA 0-5 VDC or 0-10 VDC inputs forsystem automation control and intregation
bull Provides dynamic breaking capabilitiesbull Replaces motor starter functionbull Digital readout in either Hz or RPMsbull Keypad enclosure (NEMA4X-Indoor) vsn be
mounted up to 100 from controller with cable assembly option
SYSTEM REQUIREMENTSbull In cases where the distance between the controller
and motor exceed 50 the use of a line reactor on load side is needed
bull XP motors must be UL listteedd for use with a Variable Frequency Drive
VARIABLE FREQUENCY DRIVE SELECTIONThere are some common guidelines in sizing a VFD for use on a AMETEK ROTRON blowers such as the allowable speed(table 1) for a given motor type To determine the required RPM to achieve a desired flow and pressure form a specific bloewr turn to the blower performance at variable speeds in section E of this catalog The required RPM must fall within the allowable rate of the motor being used
Motor Allowable Turndown Allowable Speedup
Standard 3600 RPM to 1800 RPM mdash3600 RPM to 900 RPM mdash
Inverter Motor 3600 RPM to 360 RPM 3600 RPM to 7200 RPM
Turndown of 101 is not typically done with regenerative blower designsFor all applications above 3600 RPM contact your Field Sales Engineer for proper horsepower sizing
Table 1
Specification
Model Number Part Number Description
IV101AE58 551529 1151 Up to 05 HP DR068-DR303 IV102AE58 551530 2301 Up to 05 HP DR068-DR303 IV101AL58 551531 1151 075 to 10 HP DR353-DR404 IV102AL58 551532 2301 or 3 075 to 10 HP DR353-DR404 IV103AL72 551533 4603 075 to 10 HP DR353-DR404 IV102AS58 551534 2301 or 3 15 to 20 HP DR454-DR505 IV103AS72 551535 4603 15 to 2 HP DR454-DR505 IV102K58 551536 2301 or 3 25 to 3 HP DR505-DR555 IV103K72 551537 4603 25 to 30 HP DR505-DR555 2301 IV102D58 551538 or 3 35 to 5 HP DR555-DR808D 4603 IV103D72 551539 35 to 5 HP DR555 to DR808D 2303 55
IV152AY58 551540 to 75 HP DR808-DR858 4603 55 to 75 IV152AY72 551541 DR808 ndash DR858 IV152BB58 551542 2303 8 to 10 HP DR858-DR909 IV153BB72 551543 4603 8 to 10 HP DR858-DR909 IV152BC58 551544 2303 105 to 15 HP DR909 IV153BC72 551545 4603 105 to 15 HP DR909 IV152BH58 551546 2303 155 to 20 HP DR9 DR14BH IV153BH72 551547 4603 155 to 20 HP DR9 DR14BH IV152BP58 551548 2303 205 to 30 HP DR13 DR14 IV153BP72 551549 4603 205 to 30 HP DR13 DR14 IV152BQ58 551550 2303 305 to 40 HP DR15 IV153BQ72 551551 4603 305 to 40 HP DR15 IV153ED72 551552 4603 505 to 60 HP DR15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
SINGLE-ENDED SIDE VIEW DOUBLE-ENDED SIDE VIEW
Air knives 30 and smallerMOUNTING VIEW
CAPPED END VIEW
CL CL25-8 NPT(TYP)
CL CL25-8 NPT(TYP)
GAP SETTINGRAIL(REF)
CL
PER MODEL
CL CL
25-20 UNC THRU
25-20 UNC X 75 LG
315 TYP
315TYP
L
458
458
22
22
075
175
10 STYP
L
PartModel Number
AK06S060 AK12S060 AK18S060 AK24S060 AK30S060 AK36S060 AK42S060 AK48S060 AK54S060 AK60S060
Specification Units 523489 552955 522949 553000 522950 523492 523493 523494 523495 523496
Length (L) Inches 930 1530 2130 2730 3330 4230 4830 5430 6030 6630 mm 2362 3886 541 6934 8458 10744 12268 13792 15316 1684
Slot Length Inches 6 12 18 24 30 36 42 48 54 60 mm 1524 3048 4572 6096 762 9144 10668 12192 13716 1524
Dimension S Inches 400 1000 1600 2200 2800 1700 2000 2300 2600 2900 mm 1016 254 4064 5588 7112 4318 508 5842 6604 7366
The ROTRON air knife is located at a strategicpoint in your assembly line conveyor beltarea Air ows from the blower into the airknife where a sheet of air is directed outthrough a proprietary linear nozzle designonto assembly line parts The opening canbe altered to adjust the air-ow rate thusvarying blow-o velocity to meet yourapplication requirements
Air KnivesAn Oil-free Blowing and Drying SystemCustom-t for Your Application
FEATURESbull Lightweight aluminum plenum and rail steel end cap
and cast-iron NPT angesbull Engineered extruded design to achieve 95 eciencybull Adjustable slot (pre-set at 0060) to control velocity
from 5000-35000 fpmbull Custom cut lengths to t system restraintsbull Oil-free and lower cost alternative to compressed air for
blow-o solution blow-back and drying applications
OPTIONSbull Chemical resistant designs utilizing Chem-Tough TM
chemically resistant surface conversion stainless steel hardware and nickel plated end caps and anges
bull Food processing grade designs utilizing Food-Tough TM
sanitary treatment surface conversion stainless steel hardware and nickel plated end caps and anges
bull Deionizers for sterile environments availablebull Mirror image single-ended models for above and below
conveyor operation
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800SCFM
Air Velocity
Precision Cleaning Air Knife and Blower Selection Chart
DR656
DR757
DR808 DR858
DR909
DRP9
DR979
DRP13
DR14
DRP15
6 knife
12 knife
18 knife
24 knife 30
knife 36 knife
42 knife
48 knife 54
knife60
knife
40000 FPM
35000 FPM
30000 FPM
25000 FPM
20000 FPM
15000 FPM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
air
These unique solenoid actuated diverter valves automatically change air piping from pressure to suction greatly enhancing blower versatility and productivity This valve is effective in blower applications that require frequent switching frompressure to suction and vice-versa They are costeffective as applications normally requiring twoblowers andor intricate piping systems may be accomplished with one blowerDiverter valves may be purchased as blowervalve assemblies or as separate stand-alone valve assemblies for use in other switched air applications
SPECIFICATIONSbull Aluminum body and spool assemblybull 303 stainless steel shaftbull 115 V-60 Hz solenoid valve
OPTIONSbull Corrosion resistant surface treatmentsbull International voltage and frequency (Hz)bull Application specific designs
DR 505 BLOWER WITH DIVERTER VALVEThe principle behind ROTRONrsquos diverter valve system is asimple one Some applications such as vacuum part pick-up airtables and pneumatic tube systems require both vacuum andpressure in their equipmentrsquos operation but not simultaneouslyThey eliminate the need for two sep-arate blowers andelaborate valving system or cyclingreversing a spinningblower impeller ROTRONrsquos diverter valve changes the airpassageways By utilizing the side vent ports for incoming oroutgoing air the equipmentpiping side of the valve changesfrom vacuum to pressure and back again by a signal sent to thesolenoid coil
PartModel Number
Specification Units 515554 037435 037482
Description - DR404 DR454 DR505 DR6 DR808 DR858 DR6 DR808 DR858 Ref Blower Model - Small Large Large Piping Flange - Threads Threads Threads Blower Flange - Face Threads Face
Dimension A Inches 765 925 925 mm 1943 235 235
Dimension B Inches 1422 2339 2339 mm 3612 5941 5941
Dimension C Inches 714 1093 1093 mm 1814 2776 2776
Dimension D Inches 250 355 355 mm 635 902 902
Dimension E Inches 500 710 710 mm 127 1803 1803
Dimension F Inches 150 250 250 mm 381 635 635
Dimension G Inches 150 250 250 mm 381 635 635
Consult factory for proper selection and application
SOLENOID
ENERGIZED POSITIONSUCTION AIR PATH
SOLENOID
DE-ENERGIZED POSITIONPRESSURE AIR PATH
A
D
BF
C
EG
EQUIPMENTPIPING SIDE ISO VALVE DRAWING
BLOWER SIDE
WORKINGPART
SUCTION PRESSURE
BlowerBlower
IN OUT IN OUT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
ROTRON RELEASED BLOWERS WITH DIVERTER VALVE MOUNTED Model Part No Mounted Components Diverter Valve Manifold
DR353BR58MV 080757DR404AL72MV 037749 517077DR404AL58MV 037715 DR454R72V 037605 515554
529397DR454R58V 037122DR505AS72MV 037709
517459DR505AS58MV 037554
037482 DR808AY72WV 080084
550667DR858BB72WV 080085
DIVERTER VALVE MANIFOLD
bull Models listed below include diverter valve and manifold
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Pressure amp Vacuum Arrangements
Pressure or vacuum guages should be located in the delivery line oriented as shown Assure that the guage is approxi-mately three pipe diameters from the blower delivery ange and that the relief valve is located at the same spacing from the guage 90deg elbows should be located at least ve pipe diameters from the blower delivery ange Elbows taps tees valves or other restrictions to air ow should not be located between the blower delivery ange and accessories described above
Failure to observe these precautions can result in false readings of guages and failure of the relief mechanism to protect the blower from overload
In order to avoid overheating or distortion of PVC pipe the rst ve to eight feet from the blower delivery ange on pressure systems should be metal
Typical Pressure System
Typical Vacuum System
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Motor Options
ROTRON strives to provide the most complete variety of desired options on our products including on our motors By using motor vendors of high quality and versatility we can provide motor features from multiple released designs to meet your needs (ie a Chem Processing Inverter Duty Explosion-proof motor with space heaters and drains wound for 380 V-50 Hzservice)
Design Consistency
ROTRON motors are engineered for us to integrally mount with our blower and maximize blower performance Our vendors are qualied by ROTRON (per motor part number) to ensure the blowersrsquo mechanical and electrical needs merge with your required features The basic motor requirements on our DRENCPHiE products include
bull NEMA approved
bull CE conformity (non-XP models)
bull UL amp CSA approved with symbol and file on nameplate
bull C-face mount
bull Permanently sealed bearings
bull Shaft end play run out and perpendicularity requirements above NEMA standards
bull Dual voltage and dual frequency (some models not feasible) to maximize use worldwide
bull Single Shafted Totally Enclosed Fan Cooled (TEFC) and Explosion-proof (XP) models
bull Double Shafted Open Drip Proof (ODP) models with dual internal fans for circulation
bull Class I Group D minimum on explosion-proof motors many are Class I Group D Class II F amp G
bull Commercial Spa (SPA-ODP) motors with automatic thermaloverload protection and industry specied terminal strip
Standard Motor Variations
Chemical Processing (CP) features are added to TEFC XP or HiE designs for corrosive gas service Marine Duty service and sanitary (foodpharmaceutical) service
bull 303 stainless steel shaft
bull Cast iron and steel frame epoxy painted or zinc plated
bull Zinc plated hardware
bull Stainless steel nameplate
bull Non-hygroscopic insulation double dipped and baked stator
bull Epoxy coating on rotor
bull Gaskets and joint sealers on all metal-to-metal surfaces
bull Oversized conduit box
High Efficiency (HiE) features are added to TEFC ODP XP or CP motors for maximum motor eciency and life ROTRON HiE motors carry extra phase-to-phase protection for use withinverters between a 1750-3500 RPM range
Inverter Duty features are added to TEFC ODP XP or CP for use with InvertersVariable Speed Drive Controllers A wide range of RPM can be handled and should be specified at time of quote For best compatibility an inverter should be matched to the motor manufacturers design
Project Specic Motor Variations
There are no limits to the options you can select or request for your product Routine motor options include
bull International voltage amp frequency (Hz)
bull Different shaft material
bull Oversized andor Nema 4 intent T-box
bull Space heaters
bull Drains
bull Regreasable bearings
bull Tropicalized windings
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Typical Sealing Options
Lo-Leaktrade LIP SEAL Option
The Lo-LeaktradeLip Seal option is available to control gas leakage for all DR models and is standard on all EN and CP models Features include Lip seals to prevent leakage at the motor shaft RTV sealingcompound is used to cut o all leakage paths at the blowerrsquos metal-to-metal surfaces Castings are vacuum impregnated to prevent leakage through castings Estimate leakage rate = 25 ccmin or less
Double Face Carbon Seal Option
For further minimization of gas leakage on all DR EN and CP models a pair of face seals work against each other on opposite sides of a common mating ring to eectively reduce gas leakageat the motor shaft The face shields are continually lubricated from a reservoir to prolong seal life The seal is completed by installing the blower to motor bolts with O-rings and sealingthe covers to the housing with an RTV sealing compound O-rings are also placed between the pipe anges and the manifold All castings are vacuum impregnatedEstimate leakage rate = 05 ccmin or less
Hermetically Sealed Spiral Containment Option
The containment option utilizes a series of O-rings to control gas leakage in Spiral blower models The O-rings are placed at critical locations on the blowerrsquos housing and covers to contain gas leakage
Hermetically Sealed Mag Drive Option
On DR EN and CP 101 units a magnet drive option has been an alternative for complete gas containmentO-rings are used throughout the product and magnets attached to the motor shaft spin magnets inside the blower without shaft penetration Estimated leakage rate = 0001 ccmi
Nitrogen Purge Blanket Option
The nitrogen purge option is a carrier designed to accept a nitrogen line which will purge the space outside the shaft hole Purges can be designed to bleed the nitrogen into the process called a blanket or the carrier can have a second tap to carry away the leaking contaminants
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chem-Toughtrade Chemical Resistance
To stand up in corrosive and hazardous environments chemical processing blowers have to be tough Thatrsquos why Ametek ROTRON routinely applies Chem-Toughtrade ROTRONrsquoS own engineered and proprietary process whenever it builds blowers for handling chemical (vapor) streams Chem-Toughtrade combines the advantages of aluminum oxide ceramic and selected uorocarbons to give ROTRON blowers unheard-of levels of chemical resistance hardness abrasion resistance permanent lubricity and more
Chem-Toughtrade Brings You the Rotron Advantage
Through this unique proprietary process Chem-Toughtrade gives ROTRON blowers these advantages
bull Outstanding Chemical ResistanceTime after time Chem-Toughtrade nishing shows extremely high resistance to most common chemicals as well as dramatically improved corrosion resistance over regular hard anodizing Chem-Toughtrade allows aluminum to achieve equivalent corrosion resistance as teonreg 90-day immersion in acid or alkaline solution (pH 40-85) has no eect neither does prolonged exposure to salt water Far exceeds military specication requirements for salt spray
bull Abrasion Resistance Equivalent to Steel Excellent for smooth surfaces Chem-Toughtrade surfaceconversion provides higher wear resistance than eithercase-hardened steel or hard-chrome plate Rub any other metal against the Chem-Toughtrade nish and the metal will show nothing but the slightest wear Chem-Toughtrade provides a perfect bond to the parent metal
bull Increased HardnessWith an equivalent hardness of Rc 40-60 Chem-Toughtrade is approximately le-hard ndash the hardness of nitrated steel Because the Chem-Toughtrade surface becomes an integral part of the metal it simply cannot peel or chip ndash neither can it bescratched aked or nicked under ordinary conditions
bull Permanent Dry LubricityBy infusing polymers into aluminum Chem-Toughtrade gives the resulting surface a high degree of permanent lubricity and resistance to moisture The polymers also level o surface asperities signicantly reducing surface tension The result blowers converted with Chem-Toughtrade have a longer life operate more eciently and call for less maintenance
bull Other Proprietary ProcessesFood-Toughtrade uses the same unique process as Chem-Toughtrade and is designed for the food processing medical andpharmaceutical markets Food-Toughtrade has USDA approval and meets FDA guidelines
Chem-Toughtrade at Work
Chem-Toughtrade employs the advantages of anodizing hardcoat plating low-friction polymers and dry lubricants to become an integral part of the blowerrsquos molecular structure
Specically Chem-Toughtrade rst converts the aluminum surface to aluminum oxide forming a new ceramic-like surface The water in the ceramic is replaced with Teonreg adding a multi-functional dimension to the surface in the process the aluminum crystals expand and form anchor crystals that remain hygroscopic for a short time Then under controlled conditions particles of the specied polymer are infused to interlock with these anchor crystals The new surface extends 5 mil above and below the original aluminum surface ndash and forms a permanent molecular bond with the metal
The result a plasticceramic surface thatrsquos harder than steel is continuously lubricating and resists damage from chemicals like no other The kind of protection you need for your chemical processing blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Acetaldehyde B C A A A A AAcetate Solv B B A A A B A B Acetic Acid B D C A B A B AAcetic Anhydride B B D A B A A B AAcetone A A A A A A A B AAcetylene A A A A A A A Acrylonitrile B C A A C BAlcohols
Amyl C C C A A A A ABENZYL B A A AButyl B C C A A A A ADiacetone A A A A AEthyl B A A A A A AHexyl A A A A AIsobutyl B A A A AIsopropyl B C A A A AMethyl B A A A A A A AOctyl A A A A APropyl A A A A A A
Aluminum Chloride 20 B D A D C D AAluminum Chloride D D B A C D C AAluminum Hydroxide A D A A A A A Alum Potassium
Sulfate (Alum) 10 A D A A A BAlum Potassium
Sulfate (Alum) 100 B A A D A B BAluminum Sulfate A D A A C C A AAmines A A B A A A A AAmmonia 10 A A AAmmonia Anhydrous B D B A A B A A AAmmonia Liquids D A A A A A A BAmmonia Nitrate C A A A A Ammonium Biuoride D C A BAmmonium Carbonate C C B A B A A A BAmmonium Chloride C D D A C A C A AAmmonium Hydroxide C A C A A A A A AAmmonium Nitrate B A D A A A A A AAmmonium Persulfate C D A A A A A AAmmonium Phosphate Dibasic A A A AB D A BAmmonium Phosphate Monobasic A A A AB A A Ammonium Phosphate Tribasic A A A AB C D A BAmmonium Sulfate B C C A C A B A AAmyl-Acetate B C A B A A C AAmyl Alcohol B A A A A AAmyl Chloride D A A C B AAniline C C A B A A A BAnti-Freeze A B C A A A AAntimony Trichloride D A D D AAromatic Hydrocarbons A A A A Arsenic Acid D D D A B A A
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Barium Carbonate B B B A B A A A ABarium Chloride D D C A C A A A ABarium Hydroxide D C C A B C A A BBarium Sulfate D C C A B A A A ABarium Sulde D C C A B A A Benzaldehyde B B A A A A A ABenzene B B C A B A A A BBenzoic Acid B D A B A A A ABenzol B A A A ABorax (Sodium Borate) C A C A A A A ABoric Acid B D A B A A A ABromine (Wet) D D D A D D D D AButadiene A C C A A A A Butane A C C A A A A Butanol A A A A AButylene A A A A A A Butyl Acetate A A A C AButyric Acid B D A B B A A ACalcium Bisulfate D D A C D A Calcium Bisulde C A B ACalcium Bisulte C A D A ACalcium Carbonate C D A B A A A ACalcium Chloride C C A C A D C ACalcium Hydroxide C A B A A ACalcium Hypochlorite C D A D A C C BCalcium Sulfate B A B A A A BCarbon Bisulde A B B A A A Carbon Dioxide (Wet) C C A A A ACarbon Disulde C B C A B A Carbon Monoxide A A A Carbon Tetrachloride C C D A B C B A ACarbonated Water A D B A A A Carbonic Acid A D A B A B A AChloracetic Acid C D A D D D D AChlorinated Glue D D A A
D C A D D D AChlorine Anhydrous LiquidChlorine (Dry) D A A B A A AChlorine Water D D A D D BChlorobenzene (Mono) B B C A A A A AChloroform D D C A A A A A AChlorosulfonic Acid D D A D D D BChlorox (Bleach) C D C A A A AChromic Acid 5 C D A A B AChromic Acid 50 C D A C B B ACitric Acid C D A A A A ACitric Oils C A A Copper Chloride D D A C D D B ACopper Cyanide D D A A A A ACopper Floborate D D A D D BCopper Nitrate D A B A A B A
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Chemical Resistance Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Copper Sulfate (5 Solution) A A A AD D A AABsloserCBAABACdicA cilyserCAAAenaxeholcyCAAAAstnegreteDAAAAAAleuFleseiDAAAAenimalyhteiDAAB
A BseyD
Epsom Salts (Magnesium Sulfate) A A A BAAAenahtE
E the Ar B A A A A BBAAACBetatecA lyhtE
ADCBC C C A A A BD C A A A BA B C A A A AA A A
edirolhC lyhtE A A A BEthylene ChlorideEthylene DichlorideEthylene GlycolEthylene Oxide
AAAADBsdicA yttaFBDDDADDedirolhC cirreF
Fer ric Nit rat De A A A A AAACAADD
D D A D D BD D D A B A C B
etafluS cirreFFerrous ChlorideFerrous Sulfate
ADDDCDDDeniroulFBBADDdicA cicilisoulFBAAAAADAedyhedlamroF
CADDDdicA cimroF A B B AAAABCB
B A D 11 noerF
Freon 12 (Wet)AB22 noerFAB311 noerFABFT noerFAAAAABCAsliO leuFAAAAAAniseR naruFBAAAAAAlarufruFAAABADDAdicA cillaG
AAAAAenilosaG A A A AAABBAenirecylG A A A A
AAAABAenatpeHAAAAABA
A A A A A A A A A A A D D D A D D D D AD D A D C A AD D A D D D BD D A D D D BD D A D D CA C A A A A C AD D A D D D BD D A C D C
enaxeHHydraulic Oils (Petroleum)Hydraulic Oils (Synthetic)Hydrobromic AcidHydrochloric Acid (Dry Gas)Hydrochloric Acid (20)Hydrochloric Acid (37)Hydrochloric Acid 100Hydrocyanic AcidHydrouoric Acid (20)Hydrouoric Acid (75)
Hydrouoric Acid 100 D D D A D D D BD D A D D BHydrouosilicic Acid (20)
Hydrouosilicic Acid C A D D CHydrogen Gas A B B A A A A Hydrogen Peroxide 10 A D A C C AHydrogen Peroxide A D D A A B A AHydrogen Sulde
Aqueous Solution C D A A A C AHydrogen Sulde (Dry) D B B A A C A AHydroxyacetic Acid (70) D Ink C D D A A A Iodine D D A D D D BIodoform A C B A B D A Isotane A Isopropyl Acetate C B Isopropyl Ether A A A A A Jet Fuel (JP3 JP4 JP5) A A A A A A A Kerosene A A B A A A A A AKetones B A A A A A A ALacquers A C C A A A Lactic Acid C D D A A A B C ALead Acetate D D A B A A ALubricants A A A A AMagnesium Chloride D D C A B B B A AMagnesium Hydroxide D B B A A A A AMagnesium Sulfate B C B A B B A BMaleic Acid B B A C A A A AMalic Acid C D A B A A A
D D D A D D D D BMercuric Chloride (Dilute Solution)Mercuric Cyanide D D A A A A Mercury C A A A A A A A AMethane A A A A A A A A AMethyl Acetate A B A A A AMethyl Acetone A A A A A A Methyl Alcohol 10 C B A A A AMethyl Butyl Ketone A A Methyl Cellosolve A Methyl Chloride D A C A AMethyl Ethyl Ketone A A A A AMethylamine A B B A A Methylene Chloride A B A A A A ANaptha A B B A A A A A ANapthalene B B A A B A B ANickel Chloride D D A A B ANickel Sulfate D D D A B A B BNitric Acid (10 Solution) D D D A A A A A ANitric Acid (20 Solution) D D A A A A ANitric Acid (50 Solution) D D A
B D A D B A B
A A A ANitric Acid
(Concentrated Solution)
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Nitrobenzene C B B A B A B BOleum B B A B A Oxalic Acid (cold) C D D A C A B A BPentane A B B A A C C BPerchloroethylene A B B A B A A Petrolatum B C C A A A Phenol 10 A B D A B A A BPhenol (Carbolic Acid) B D D A B A A A APhosphoric Acid
(to 40 Solution) D D A B A A APhosphoric Acid
(40-100 Solution) D D A C B B APhosphoric Acid (Crude) D D D A D C C A
D A A A Phosphoric Anhydride (Molten)Photographic (Developer) C D C A C APhthalic Anhydride B C C A B A B APicric Acid C D D A B A A APotash C B A A APotasium Bicarbonate C D A A B BPotassium Bromide C D D A A A B BPotassium Carbonate C B B A B A A APotassium Chlorate B B B A B A A A BPotassium Chloride B B B A C A A B APotassium Chromate A A B B B
D B B A BPotassium Cyanide Solutions A B A APotassium Dichromate A B C A B A A A BPotassium Ferrocyanide C C A B A A B
D C A A APotassium Hydroxide (50) B B B APotassium Nitrate B B A B A B A BPotassium Permanganate B B B A B A B B BPotassium Sulfate A B B A B A B B APotassium Sulde B B B A A A A BPropane (Liquied) A B A A A A Propylene Glycol A B B A B B A Pyridine B B A A C B Pyrogallic Acid B B B A B A A A ASilver Bromide D C C B Silver Nitrate D D D A B A B A ASodium Acetate B C C A B A A B ASodium Aluminate C C A B A BSodium Bicarbonate A C C A B A A A Sodium Bisulfate D D D A A A A BSodium Bisulte A D A A A BSodium Borate C C C A B A A ASodium Carbonate C B B A B A B B ASodium Chlorate B C A B A A BSodium Chloride C B C A B A C B ASodium Chromate D B B A A A A BSodium Cyanide D B B A B A A Sodium Fluoride C D D A B C C A
Sodium Hydrosulte A A ASodium Hydroxide (20) D A A
D B A A B AD C A A D BD C A A D B
A A A ASodium Hydroxide (50 Solution)Sodium Hydroxide (80 Solution)Sodium Hypochlorite (to 20)Sodium Hypochlorite D D D A D A ASodium Hyposulfate D A A A Sodium Metaphosphate A B B A A A Sodium Metasilicate B C C A A A Sodium Nitrate A A B A B A A A BSodium Perborate B B B A B C Sodium Peroxide C D C A B A A BSodium Polyphosphate
(Mono Di Tribasic) D A A A ASodium Silicate C B A B A B A BSodium Sulfate B A B A B A A C BSodium Sulde D A B A B A B BSodium Sulte C A A C C A
B C B A A A A Sodium Thiosulphate (ldquoHypordquo)Stannic Chloride D D D A D D D BStannous Chloride D D D A D D C AStearic Acid B C C A B A A A AStoddard Solvent A B B A A A A A AStyrene A A A A A A Sulfate Liquors B C C ASulfur Chloride D A D D D Sulfur Dioxide A A A A C BSulfur Dioxide (Dry) A A B A A A A ASulfur Trioxide (Dry) A B B A A A C Sulfuric Acid (to 10) C D A D C C ASulfuric Acid (10-75) D D A D D D BSulfurous Acid C D D A C C B C BTannic Acid C C C A B A A A BTanning Liquors C A A A ATartaric Acid C D D A B A B B BTetrahydrofuran D D A A A A Toluene Toluol A A A A A A A ATrichlorethane C C A C A ATrichlorethylene B C B A B A A AWater Acid Mine C C A A
B D A A A Water Distilled Lab Grade 7Water Fresh A B D A A A A Water Salt B D A A Weed Killers C A A Whiskey and Wines D D D A A A A A Xylene A A B A A A A AZinc Chloride D D D A D A B B BZinc Hydrosulphite D D A Zinc Sulfate D C D A B A A A B
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Flow
bull Volume RateTimebull ROTRON charts are in SCFM m3min or LSbull SCFM = Standard Cubic Feet Per Minute (American) where
temperature = 68degF air density = 0075 lbcubic foot and altitude = 0 feet above sea level
bull M3min = Cubic Meters Per Minute (Metric)bull Lsec = Liters Per Second (Metric)bull 1 m3min = 353 SCFMbull 1 Lsec = 2119 SCFMbull See Standard Engineering Conversions for other flows on
pg I-2
Throughout our catalog you will find terminology used for air moving selection and product sizing Below are a few of the key terms
Specic Gravity
bull Density Ratio Relative to Airbull Standard Air SG = 10bull Methane SG = 055bull See Specific Gravity Chart for other gases on pg I-4
Pressure
bull ForceAreabull ROTRON charts are in IWG PSIG MM of Water IHG or mbarbull IWG = Inches of Water Gauge (American)bull PSIG = Pounds Per Square Inch Gauge (American)bull MM of Water = Millimeter of Water Gauge (Metric)bull IHG = Inches of Mercury Gauge (American)bull mbar = Millibar Gauge (Metric)bull PSIA = Pounds Per Square Inch Absolute (American)bull 277 IWG = 1 PSIGbull 70358 MM of Water = 1 PSIGbull 2036 IHG = 1 PSIGbull 0069 Bars = 69 mbar = 1 PSIGbull Standard Atmosphere = 0 PSIG = 147 PSIAbull See Basic Fan Laws Chart for correcting pressure due to speed
or density changes on pgs I-5 and I-6
Density
bull WeightVolumebull Standard Air = 0075 lbcubic footbull See Density Chart for other gases on pg I-4bull See Density Correction Chart due to altitude and temperature
changes on pg I-3
Velocity
bull DistanceTime or FlowAreabull FPM = Feet Per Minute (American)bull MPH = Miles Per Hour (American)bull Mmin = Meters Per Minute (Metric)bull Kmh = Kilometers Per Hour (Metric)bull 88 FPM = 1 MPHbull 2682 Mmin = 1 MPHbull 1609 Kmh = 1 MPHbull See Standard Engineering Conversion Chart for other
velocities on pg I-2bull See Orifice Flow Calculation Chart for air flow equations on
pg I-7
Pressure Drop Back Pressure Impedance
bull Friction causes air to slow down and lost energy is measured in pressure drop terms
bull Typical pressure drop areas include piping elbows accessories and system
bull Each fixed system has a fixed system impedance caused by a single or multiple pressure drop points
bull Changing the system impedance will cause blowers work point to change
bull Changing the blower with fixed system impedance will change the working back pressure
bull See Friction Loss Per Foot of Tubing and Fitting Charts on pg I-8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Engineering Conversion
MULTIPLY BY TO OBTAINAtmospheres 760 Cms of MercuryAtmospheres 2992 Inches of MercuryAtmospheres 3390 Feet of WaterAtmospheres 10333 KgsSq InchAtmospheres 1013 x 105 PascalsAtmospheres 1470 PoundsSq InchAtmospheres 760 TorrsBars 09869 AtmospheresBars 1 x 106 DynesSq CmBars 1020 x 104 KgsSquare MeterBars 1450 PoundsSq InchBritish Thermal Units 02520 Kilogram-CaloriesBritish Thermal Units 7775 Foot-PoundsBritish Thermal Units 3927 x 10-4 Horsepower-HoursBritish Thermal Units 1054 JoulesBritish Thermal Units 1075 Kilogram-MetersBritish Thermal Units 2928 x 10-4 Kilowatt-HoursCentimeters of Mercury 001316 AtmospheresCentimeters of Mercury 04461 Feet of WaterCentimeters of Mercury 1360 KgsSquare MeterCentimeters of Mercury 01934 PoundsSq InchCentimetersSecond 1969 FeetMinuteCentimetersSecond 06 MetersMinuteCubic Centimeters 3531 x 10-5 Cubic FeetCubic Centimeters 6102 x 10-2 Cubic InchesCubic Centimeters 10-6 Cubic MetersCubic Centimeters 10-3 LitersCubic Feet 2832 x 104 Cubic CmsCubic Feet 1728 Cubic InchesCubic Feet 002832 Cubic MetersCubic Feet 003704 Cubic YardsCibic Feet 7481 GallonsCubic Feet 2832 LitersCu Ft of Water (60degF) 6237 PoundsCubic FeetMinute 4720 Cubic CmsSecCubic FeetMinute 04720 LitersSecondCubic FeetMinute 624 Lbs of WaterMinCubic Inches 1639 Cubic CentimetersCubic Inches 5787 x 10-4 Cubic FeetCubic Inches 1639 x 10-5 Cubic MetersCubic Inches 2143 x 10-5 Cubic YardsCubic Meters 106 Cubic CentimetersCubic Meters 3531 Cubic FeetCubic Meters 61023 Cubic InchesCubic Meters 1308 Cubic YardsCubic Yards 7646 x 105 Cubic CentimetersCubic Yards 27 Cubic FeetCubic Yards 46656 Cubic InchesCubic Yards 07646 Cubic MetersFeet 3048 CentimetersFeet 12 InchesFeet 03048 MetersFeet 13 YardsFeet of Air
(1 atmosphere 60degF) 530 x 10-4 PoundsSquare InchFeetMinute 05080 CentimetersSecFeetMinute 001667 FeetSecondFeetMinute 001829 KilometersHourFeetMinute 03048 MetersMinuteFeetMinute 001136 MilesHourGramsCu Cm 6243 PoundsCubic FootHorsepower 4244 British Thermal UnitsMinHorsepower 33000 Foot-PoundsMinHorsepower 1070 Kg-CaloriesMinHorsepower 7457 WattsHorsepower-Hours 2547 British Thermal UnitsInches 2540 CentimetersInches 103 MilsInches of Mercury 003342 AtmospheresInches of Mercury 1360 Inches of WaterInches of Mercury 3453 KgsSquare MeterInches of Mercury 2540 Mms of MercuryInches of Mercury 04912 PoundsSquare InInches of Water 0002458 AtmospheresInches of Water 007355 Inches of MercuryInches of Water 2540 KgsSquare MeterInches of Water 5204 PoundsSquare FtInches of Water 003613 PoundsSquare In
MULTIPLY BY TO OBTAINKGSCubic Meter 006243 PoundsCubic FootKilometers 3281 FeetKilowatts 5692 British Thermal UnitsMinKilowatts 7376 Foot-PoundsSecKilowatts 1341 HorsepowerKilowatts 1434 Kg-CaloriesMinKilowatt-Hours 3415 British Thermal UnitsLiters 103 Cubic CentimetersLiters 6102 Cubic InchesLiters 10-3 Cubic MetersLog10N 2303 LogEN or Ln NLog N or Ln N 04343 Log10NMeters 100 CentimetersMeters 32808 FeetMeters 3937 InchesMeters 10-3 KilometersMetersMinute 1667 CentimetersSecMetersMinute 3281 FeetMinuteMetersMinute 006 KilometersHourMetersMinute 003728 MilesHourMiles 5280 FeetMiles 16093 KilometersMiles 1760 YardsMilesHour 4470 CentimetersSecMilesHour 88 FeetMinuteMilesHour 1467 FeetSecondMilesHour 16093 KilometersHourMilesHour 2682 MetersMinuteMms of Mercury 00394 Inches of MercuryMms of Mercury 13595-3 KgsSquare CmMms of Mercury 001934 PoundsSquare InchPints (Liq) 2887 Cubic InchesPints (US liquid) 473179 Cubic CentimetersPints (US liquid) 16 Ounces (US fluid)Pounds 444823 DynesPounds 4536 GramsPounds 16 OuncesPounds of Carbon to CO2 14544 British Thermal Units (mean)Pounds of Water 2768 Cubic InchesPounds of Water 01198 GallonsPounds of Water
Evaporated at 212degF 9703 British Thermal UnitsPoundsCubic Foot 1602 KgsCubic MeterPoundsSquare Foot 4882 KgsSquare MeterPoundsSquare Inch 006804 AtmospheresPoundsSquare Inch 277 Inches of WaterPoundsSquare Inch 2036 Inches of MercuryPoundsSquare Inch 7031 KgsSquare MeterPoundsSquare Inch 6895 x 103 PascalsPoundsSquare Inch 51715 Millimeters of Mercury at 0degCSquare Centimeters 1973 x 105 Circular MilsSquare Centimeters 1076 x 10-3 Square FeetSquare Centimeters 01550 Square InchesSquare Feet 9290 Square CentimetersSquare Feet 009290 Square MetersSquare Inches 1273 x 106 Circular MilsSquare Inches 6452 Square CentimetersSquare Inches 6944 x 10-3 Square FeetSquare Inches 106 Square MilsSquare Inches 6452 Square MillimetersSquare Kilometers 1076 x 106 Square FeetSquare Kilometers 106 Square MetersSquare Kilometers 1196 x 106 Square YardsSquare Meters 10764 Square FeetSquare Meters 1196 Square YardsTemp (Degs C) + 273 1 Abs Temp (Degs C)Temp (Degs C) + 178 18 Temp (Degs Fahr)Temp (Degs F) + 460 1 Abs Temp (Degs F)Temp (Degs F) -32 59 Temp (Degs Cent)Watts 005692 British Thermal UnitsMinWatts 107 ErgsSecondWatts 4426 Foot-PoundsMinWatts 1341 x 10-3 HorsepowerWatts 001434 Kg-CaloriesMinWatts 10-3 KilowattsWatts-Hour 3415 British Thermal UnitsWatts-Hour 1341 x 10- HorsepowerHoursWatts-Hour 10-3 Kilowatt-Hours
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Density Correction Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Specic Gravity and Density of Various Gases at 60degF (1 ATM)
ChemicalFormula
Density(lbscu ft)
Gas or Vapor Specic Gravity
Acetylene 0899 0686Air 100 0763Ammonia 0587 0454Argon 1377 1053Benzene 270 205Carbon Dioxide 1539 1166Chlorine 2448 0738Ethane 1038 0799Ethylene 0969 0739Helium 0138 01054Hydrogen 00695 00531Hydrogen Sulde 119 0897Methane 0555 0424Methyl Chloride 1785 1356Nitrogen 0967 0738Oxygen 1105 0843Propane 155 1180Sulfer Oxide 226 1720Water Vapor 0622
C2H2
-NH3
AC6H6
CO2
CI2
C2H6
C2H4
HeH2
H2SCH4
CH3CIN2
O2
C3H8
SO2
H2O 0373
Explosive Atmosphere Classication
NEMA Classications
North American European
Class I Zone 1Group A AcetyleneGroup B Group II C
Group II CHydrogen or equivalent hazard
Group C Group II B Ethyle ether vapors ethylene orcyclopropane
Group D Group II A Gasoline hexane naptha benzenebutane alcohol acetone benzol lacquer vapors or natural gas
Class IIGroup E Metal dustGroup F mdash
mdashCarbon black coal or coke dust
Group G mdash Flour starch or grain
Temperature Conversion Chart
degC Temp degF degC Temp degF degC Temp degF degC Temp degF-789 -110 -166 17 35 950 272 81 1778 182 360 680-733 -100 -148 22 36 968 278 82 1796 188 370 698-678 -90 -130 28 37 986 283 83 1814 193 380 716-622 -80 -112 33 38 1004 289 84 1832 199 390 734-567 -70 -94 39 39 1022 294 85 1850 204 400 752-511 -60 -76 44 40 1040 300 86 1868 210 410 770-456 -50 -58 50 41 1058 306 87 1886 216 420 788-400 -40 -40 56 42 1076 311 88 1904 221 430 806-344 -30 -22 61 43 1094 317 89 1922 227 440 824-289 -20 -4 67 44 1112 322 90 1940 232 450 842-233 -10 14 72 45 1130 328 91 1958 238 460 860-178 0 32 78 46 1148 333 92 1976 243 470 878-172 1 338 83 47 1166 339 93 1994 249 480 896-167 2 356 89 48 1184 344 94 2012 254 490 914-161 3 374 94 49 1202 350 95 2030 260 500 932-156 4 392 100 50 1220 356 96 2048 266 510 950-150 5 410 106 51 1238 361 97 2066 271 520 968-144 6 428 111 52 1256 367 98 2084 277 530 986-139 7 446 117 53 1274 372 99 2102 282 540 1004-133 8 464 122 54 1292 378 100 2120 288 550 1022-128 9 482 128 55 1310 43 110 230 293 560 1040-122 10 500 133 56 1328 49 120 248 299 570 1058-117 11 518 139 57 1346 54 130 266 304 580 1076-111 12 536 144 58 1364 60 140 284 310 590 1094-106 13 554 150 59 1382 66 150 302 316 600 1112-100 14 572 156 60 1400 71 160 320 321 610 1130
-94 15 590 161 61 1418 77 170 338 327 620 1148-89 16 608 167 62 1436 82 180 356 332 630 1166-83 17 626 172 63 1454 88 190 374 338 640 1184-78 18 644 178 64 1472 93 200 392 343 650 1202-72 19 662 183 65 1490 99 210 410 349 660 1220-67 20 680 189 66 1508 100 212 413 354 670 1238-61 21 698 194 67 1526 104 220 428 360 680 1256-56 22 716 200 68 1544 110 230 446 366 690 1274-50 23 734 206 69 1562 116 240 464 371 700 1292-44 24 752 211 70 1580 121 250 482 377 710 1310-39 25 770 217 71 1598 127 260 500 382 720 1328-33 26 788 222 72 1616 132 270 518 388 730 1346-28 27 806 228 73 1634 138 280 536 393 740 1364-22 28 824 233 74 1652 143 290 554 399 750 1382-17 29 842 239 75 1670 149 300 572 404 760 1400-11 30 860 244 76 1688 154 310 590 410 770 1418-06 31 878 250 77 1706 160 320 608 416 780 1436
0 32 896 256 78 1724 166 330 626 421 790 145406 33 914 261 79 1742 171 340 644 427 800 147211 34 932 267 80 1760 177 350 662 432 810 1490
In the center column nd the temperature to be converted The equivalent temperature is in the left column if converting to Celsius and in the right column if converting to Fahrenheit
degF = 95C + 32 ABSOLUTE RANKIN (R) R = degF + 460degC = 59 (F - 32) ABSOLUTE KELVIN (K) K = degC + 273
Ref NEMA Standards Publication Pub No 1CSndash1970
NEMA Type 1 ndash General Purpose ndash IndoorType 2 ndash Dripproof ndash IndoorType 3 ndash Dusttight Raintight and Sleet (Ice)
Resistant ndash Outdoor3R ndash Rainproof and Sleet (Ice) Resistant
ndash Outdoor3S ndash Dusttight Raintight and Sleet (Ice)
Proof ndash OutdoorType 4 ndash W atertight and Dusttight ndash Indoor
4X ndash W atertight Dusttight and CorrosionResistant ndash Outdoor
Type 5 ndash Superseded by Type 12 for ControlApparatus
Type 6 ndash Submersible Watertight Dusttight andSleet Resistant ndash Indoor and Outdoor
Type 7 ndash Class I Group A B C or D HazardousLocations Air Break Equipment ndash Indoor
Type 8 ndash Class I Group A B C or D Hazardous Locations Oil-immersed Equipment ndash Indoor
Type 9 ndash Class II Group E F or G HazardousLocations Air-break Equipment ndash Indoor
Type 10 ndash Bureau of MinesType 11 ndash Corrosion Resistant and Dripproof
Oil-immersed ndash IndoorType 12 ndash Industrial Use Dusttight and Driptight
ndash IndoorType 13 ndash Oiltight and Dusttight ndash Indoor
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Physical Laws for Blower Applications
In the following formulae these symbols are used
P ndash Pressure in pounds per square inch (PSI) or inches ofmercury column (inches Hg)
CFM ndash Volume in cubic feet per minuteRPM ndash Speed in revolutions per minuteD ndash Density in pounds per cubic foot (lbscu ft)H ndash Height of air or gas column (ft)SG ndash Specic Gravity (ratio of density of gas to the density
of air)
ldquoStandard Airrdquo ndash Air at 68degF (absolute temperature 528deg) and 2992rdquo Hg (barometric pressure at sea level) The density of such air is 0075 lbscu ft and the specic volume is 1329 cu ftlb The specic gravity is 10
The outlet pressure of a blower depends on the condition of the air or gas at the inlet The inlet condition is inuenced bya ndash Specic gravity (The ratio of density of the gas to density of
standard air)b ndash Altitude (location of blower)c ndash Temperature of inlet air
Volume
Pressure
The Volume changes in direct ratio to the speedExample ndash A blower is operating at 3500 RPM and delivering 1000 cfm If the speed is reduced to 3000 RPM what is the new volume
Basic Fan Laws Chart
V REWOPESROHERUSSERPEMULOVELBAIRA
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio
Varies DIRECT with Density Ratio Varies DIRECT with Density Ratio
Varies with CUBE of Speed Ratio
CFM 2 = CFM 1 ( RPM 2 ) P 2 = P 1 ( RPM 2 )2 HP 2 = HP 1 ( RPM 2 )3
RPM 1 RPM 1 RPM 1
WHEN DENSITY CHANGES Does Not Change
P 2 = P 1 ( D2 ) HP 2 = HP 1 ( D2 )D1 D1
V 1 = Original Volume (1000 CFM)V 2 = New VolumeRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
V 2 = V 1 ( RPM 2 )1= 1000 x ( 3000 )1
= 1000 x 857 = 857 CFMRPM 1 3500
Pressure (barometric) varies in direct proportion toaltitudeExample ndash A blower is to operate at an elevation of 6000 feetand is to deliver 3 PSI pressure What pressure (standard air)blower is required
Pressure = 3 x 2992
= 375 or 3 34 lb2398
If it is desired to determine what pressure a 3 lb (standard air)blower will deliver at 6000 feet ndash
Pressure = 3 x 2398
= 24 or about 2 12 lb2992
When a blower is to operate at a high altitude it is frequentlyspecied that the blower be capable of handling a given vol-ume of ldquostandard airrdquo It is then necessary to determine theequivalent volume of air at the higher altitudeExample ndash A blower is to operate 6000 feet altitude and is tohandle 1000 CFM of standard air What is the CFM of air theblower must handle at 6000 feet altitude
Let V 1 = Volume of standard air (1000 CFM)V 2 = Volume of thinner airHg1 = Barometric pressure sea level (2992)Hg2 = Barometric pressure 6000rsquo (2398)
V 2 = V 1 x Hg
1 = 1000 x 2992
= 1248 CFMHg 2 2398
The pressure changes as the square of the speed ratio
Example ndash A blower is operating at a speed of 3500 RPM anddelivering air at 50 pounds pressure If the speed is reduced to3000 RPM what is the new pressure
P 1 = Original Pressure (5 lbs)P 2 = New PressureRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
P 2 = P 1 ( RPM 2 )2= 5 x ( 3000 )2
= 5 x 735 = 368 poundsRPM 1 3500
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Pressure (Contrsquod)
Horsepower
The Air Density varies in inverse proportion to theabsolute temperatureExample ndash A blower is to handle 200degF air at 3 PSI pressureWhat pressure (standard air) blower is required
Let P 1 = Pressure hot air (3 PSI)P 2 = Pressure standard airAT 1 = Absolute temperature hot air (200+460=660degF)AT 2 = Absolute temperature standard air (68+460=528degF)
P 2 = P 1 x AT
1 = 3 x 660 = 375 or 3 34 lbAT 2 528
A blower is capable of delivering 3 PSI pressure with standardair What pressure will it develop handling 200degF inlet air
P 1 = P 2 x AT
2 = 3 x 528 = 24 or about 2 12 lbAT 1 660
Pressure varies in direct proportion to the densityExample ndash A 3 lb (standard air) blower is to be used to handlegas having a specic gravity of 05 What pressure does theblower create when handling the gas
Let Pa = Air pressure (3 lb)Pg = Gas pressureSG = Specic gravity of gas (05)
Pg = Pa x SG = 3 x 5 = 15 lb
If we are required to handle a gas having a specic gravity of 05at 15 lb pressure we can determine the standard air pressureblower as follows
Let Pa = Pg
= 15
= 3 lbSG 5
The following table gives the barometric pressure of various altitudesAbsolute Pressure At Altitudes Above Sea Level (Based on US Standard Atmosphere)
Altitude
0500
Feet In Hg PSIA Feet In Hg PSIA Feet In Hg PSIA
600700800900
100015002000
299229382928291829072897288628332782
147014431438143314281423141813901367
250030003500400045005000550060006500
273126812632258425362489244323982353
134113191292127012451223120011771156
700075008000850090009500
10000
2309226522222180213820982058
1134111210901070105010901010
Pressure Altitude Pressure Altitude Pressure
The horsepower changes as the cube of the speed ratioExample ndash A blower is operating at a speed of 3500 RPM andrequiring 50 horsepower If the speed is reduced to 3000 RPMwhat is the new required horsepower
HP 1 = Original Horsepower (50)HP 2 = New HorsepowerRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
HP 2 = HP 1 x (RPM 2)3= 50 x (3000 )3
= 50 x 630 = 315 horsepowerRPM 1 3500
The above is known as the 1-2-3 rule of blowers
Horsepower vs Specic Gravity amp Ratio of densityThe horsepower varies in direct proportion to the specic gravity(ratio of density of gas to density of air)Example ndash A standard air blower requires a 10 HP motor Whathorsepower is required when this blower is to handle a gaswhose specic gravity is 05
HP = 10 x 05 = 5 horsepower
It is possible that several of the above modications may berequired on one installation Therefore it may be necessary touse various combinations of these formulae
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Orice Flow
Orice Flow CalculationTo determine air ow through an orice
V = CK radic P Q = AV VP = ( V ) 2K
WhereV = V elocity in feet per minute (fpm)C = Orice CoecientK = Constant = 14786 when P is expressed
in In Hg21094 when P is expressedin PSIG4005 when P is expressedin In of Water
(Above constants are based on an air densityof 0075 lbsft 3)
P = Pressure dierential across the oriceQ = Flow rate in cubic feet per minute (CFM)A = T otal orice area expressed in square feetVP = Velocity pressure (units are those of pressure)
Coecient C for Orices UnderVacuum or Pressure Flow
Area of OricesOrice Diameter in Inches
Diameterin Inches Square Inches Square Feet
18 01227 000085316 02761 0001914 04908 0003438 11044 0007612 19634 0013658 30679 0021378 60132 0041710 78539 00545
Orice area (in sq inches) = 25 X π X (orice diameter in inches) 2
Orice area (in sq feet) = Area in sq inches divide 144
ORIFICE PRESSURE DROP AS A FUNCTIONOF FLOW AND ORIFICE AREA (C=65)
c-98 c-92 c-82 c-80
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
c-72 c-65 c-80 c-53
15
30
45
60
75
90
105
120
135
150
20
40
60
80
100
120
140
160
180
20
0 100 200 300Flow Rate SCFM
400 500
500 700 900 1100Flow Rate SCFM
1300 1500
1500 1700 1900 2100Flow Rate SCFM
2300 2500
40
60
80
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Friction Loss Per Foot of Tubing
Friction Loss in Fittings
To calculate friction loss in ttings use chart below This chart will yield equivalentlengths (in feet) of tubing Use this length with graph above to nd friction loss ininches of water column
NOMINAL PIPE SIZE (INCHES) EQUIVALENT TUBING LENGTH (FEET)
90deg EL 45deg EL
1 14 3 151 12 4 2
52 252 12 6 3
47314 0 515 2 616 5 7528 0 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Noise Facts
Loudness Levels of Familiar Noises (Approximate Average Including Ear Nework)
bull OSHA (Occupational Safety amp Health Administration) regulates and monitors in-plant noisebull Allowable noise is a function of dBA level at certain distance over an exposure timebull OSHA regulations state 90 dBA for an 8 hour work period using slow responic setting on meterbull Adding a second noise producer of equal dBA will add 3 dBA to the first dBA readingbull Sound pressure level (SPL) decreases with distance (d)
(SPL) 2 = (SPL) 1 - 20LOG ( d2 )d1
Therefore each doubling of distance results in 6 dBA reduction
Threshold of Painful Feeling
Airplane and Propeller at 10
Ft
Train Passing at High Speed
Riveter at 30 Ft Auto Horn at 20 Ft Pneumatic Drill at 10 FtSubway TrainFire Siren at 75 Ft Noisy Street RailwayNoisy StreetPolice Whistle at 15 Ft Auto at 60 MPH
Very Noisy Restaurant Auto at 40 MPH Average Stenographic Room
Factories Auto at 20 MPHNoise in Pullman (Windows Shut)Noisy OfficeAverage RestaurantDept Store Average Conversation at 3 FtAverage Office Quiet Street Noisy ResidenceQuiet Restaurant Quiet OfficeMuseumAverage School Average Residence Motion Picture Theater Library Reading Rooms AuditoriumsAverage Whisper at 5 Ft Very Quiet Residence
Broadcasting Studio Zero of AIEE Scale 14 Db
Zero of Original Scale 85
Db Threshold of Audibility
1013 130
1012 120
1011 110
1010 100
109 90
108 80
107 70
106 60
105 50
104 40
103 30
102 20
10 10
1 1
Loud
ness
Lev
els
in D
ecib
els
Rel
ativ
e In
tens
ities
(Int
ensi
ty A
bove
Thr
esho
ld =
10
16 w
atts
per
sq
cm
)
A P
P R
O X
I M
A T
E
N O
I S
E
L E
V E
L S
DEAFENING
NOISY
AVERAGE
QUIET
VERY QUIET
SOUND PROOFR OOMS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 91258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Industrial Blower Noise Chart in dBA
dBA at Distance Conversion Chart
Average at 1 meter 4 places around the blower
Mode
Suction
SEMFRDCSL2SL4SL5
60-6264-6576-7869-7272-7876-79
60-6264-6576-7869-7272-7876-79
101202303353404454
65-6767-6965-6772-7373-7476-77
66-6868-7067-6973-7474-7575-76
5135055235556566
80-8177-7882-8380-8182-8385-86
80-8176-7782-8380-8182-8385-86
757808633S7858833
83-8584-8581-8288-8984-8582-84
84-8684-8581-8288-8984-8582-84
SP 99091233SP 13
14SP 15
90-9181-8284-8587-8886-8791-92
90-9184-8684-8590-9186-8791-92
Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure
Mode Mode Mode ModeModel Model Model Model Model
To read use straight edge to connect blower distance and dBA rating A pivot point A will be developed Use straight edge again with new distance and pivot point A to read dBA at new distance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 101258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference
Special Features 0 to 4 letters- see gure 2
Voltage Code up to 3 numbers - see gure 1
Motor Description - see gure 3(TEFC XP Chem and ODP)
Describes which family the unit belongs to 1 to 3 numbers
Option for duplex units onlyP = Parallel congurationS = Series conguration
DR = Domestic RegenerativeEN = EnvironmentalCP = Chemical ProcessHiE = Hi Eciency Motor
Figure 1 Voltage Code
Figure 2 Special Features
This chart explains the nomenclature behind the catalogued blower model names This tool can be used to explainto customers what the letters and numbers mean and will also allow you to become familiar with our model namesThis information should not aect the way orders are placed please continue to use the model names shown inthe catalog and price pages Any special request should be noted on the order
5 230 VAC 60 Hz Single Phase9 115230 VAC 5060 Hz Single Phase33 230 VAC 60 Hz Three Phase58 115230 VAC 60 Hz Single Phase60 200 VAC 5060 Hz Single Phase72 230460 VAC 60 Hz Three Phase75 380 VAC 50 Hz Three Phase86 575 VAC 60 Hz Three Phase89 200-230460 VAC 60 Hz Three Phase91 230460 VAC 5060 Hz Three Phase92 415 VAC 50 Hz Three Phase201 380 VAC 60 Hz
A SPECIAL (not covered by any other letter)BC Blower on pressure onlyD Blower on suction onlyEFGH Vapor recovery service - hydrocarbonJ Nasty Gas face sealKL Lo leak option (lip seal)M Die Cast or muer extensionPQR Chem-Toughtrade constructionS Special manifoldTUV V alveW Rail mounted blowerX Base mounted blowerY Slip on angeZ Package blower coupling driveAA Package blower belt drive simplexBB Package blower drive belt duplexRD Remote driveNT No Tower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference (Contrsquod)
HP Motor ThermalType Protection
HP Motor ThermalType Protection
Figure 3 Motor Description
DEFKMRVWXYADAEAGAKALARASAWAXAYBABBBCBDBEBGBHBKBLBMBPBQBRBXCBCCCD
CJCKCRCSCTCUDCDJDWDXEEEZFAFBFDFEFFFGFHFJFKFLFMFNFQFRFSFUFWFXFYFZGAGBGCGD
RD
25404030201018
11630306015121434255
75101530551412101520305055751015203020
XPTEFC
CHEM TEFCCHEMTEFCCHEM TEFCCHEM TEFC
TEFCTEFCTEFC
XPODP
CHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFC
XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XP
YesNoNoNoNoNoYesYesNoYesNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesYesYesYesYesYesYesYesYesYesYesNo
50505030301515157513131212121010202020757510101015152020152030403414141425
TEFCODPXP
TEFCXP
TEFCODPXP
ODPTEFC
XPTEFC
XPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCXP
ODPODPODPODPTEFCTEFCODPXP
TEFC
NoNoYesNoYesNoYesYesNoNoYesNoNoYesNoYesNoYesYesNoYesNoNoYesNoYesNoYesNoNoNoNoNoNoYesYesNo
CHEM TEFCTEFC
Remote Drive - No MotorGE 115 No
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Corrosion-Resistant and Sanitary Blowers Application Data Sheet
To obtain Application Engineering assistance or a quotation for your specific need please photocopy thisform fill out as much as possible and fax it back to Rotron We look forward to working with you
COMPANY
CONTACT
ADDRESS
ADDRESS
ZIPS TAT EC IT Y
FAXP HONE
GAS CONCENTRATION DESCRIPTIONPercentage Gas Specific Gravity
________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )___ __ _______________ (SG = _______ )
Corrosive Yes No Explosive Yes NoGAS
CLASSIFICATION
AREA
CLASSIFICATION
Corrosive Yes No Explosive Yes No
PERFORMANCE REQUEST Fill in and circle choice
SCFM deg (F C)FLOW INLET TEMPERATURE
PSI (A G) deg (F C)INLET PRESSURE AREA AMBIENT TEMPERATURE
PSI (A G) (Ft M)OUTLET PRESSURE SITE ALTITUDE
___ 100
APPLICATION DESCRIPTION Attach sketch if necessary
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 131258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Warranty Statement
Warranty Statements
1 AMETEK ROTRON DR EN and HiE regenerative direct drive blowers are guaranteed for one full year from the date of installation (limited to 18 months from the date of shipment) to the original purchaser only Should blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related
2 Standard Products - AMETEK ROTRON moisture separators remote drives packaged units CP blowers Nasty GasTM models and special built (EO) products are guaranteed for one full year from the date of shipment for workmanship and material defect to the original purchaser only Should the blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related we will at our option repair or replace the blower
3 Parts Policy - AMETEK ROTRON spare parts and accessories are guaranteed for three months from the date of shipment for workmanship and material defect to the original purchaser onlyIf failure is determined to be workmanship or material defect related we will at our option repair or replace the part
4 Non-Standard Products - Orders for specially-built products will be concidered as non-cancellable Any requested changed by customer after order acceptance will result in additional charges
Corrective Action - A written report will be provided indicating reason(s) for failure with suggestions for corrective action Subsequent customer failures due to abuse misuse misapplica-tion or repeat oense will not be covered AMETEK ROTRON will then notify you or your options Any failed unit that is tampered with by attempting repair or diagnosis will void the warranty unless authorized by the factory
Terms and Conditions - Our warranty covers repairs or replace-ment or regenerative blowers only and will not cover labor for installation outbound and inbound shipping costs accessories or other items not considered integral blower parts Charges may be incurred on products returned for reasons other than failures covered by their appropriate warranty Out-of-warranty product and in warranty product returned for failures deter-mined to be caused by abuse misuse or repeat oense will be subject to an evaluation charge Maximum liability will in no case exceed the value of the product purchased Damage resulting from mishandling during shipping is not covered by this warranty It is the responsibility of the purchaser to le claims with the carrier Other terms and conditions of sale are stated on the back of the order acknowledgement
Hazardous Locations Policy
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous explosive location without proper NEMA motor enclosure AMETEK ROTRON does not recognize sealed blowers as a substitue for explosion-proof motors Sealed units with standard TEFC motors should never be utilized where local state andor federal codes specify the use of explosion-proof equipment
AMETEK ROTRON has a complete line of regenerative blowers with explosion-proof motors Division 1 amp 2 Class I Group D Class II Groups F amp G requirements are met with these standard explosion-proof blowers
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous corrosive environment without the proper surface treatment and sealing options
AMETEK ROTRON has a complete line of Chemical Processing and Nasty GasTM regenerative blowers with Chem-ToughTM stainless steel parts and seals
AMETEK ROTRON oers general application guidance however suitability of the particular blower selection is ultimately the responsibility of the purchaser not the manufacturer of the blower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 14Customer Service Fax +1 2152561338 wwwametekdfscom
AMETEK Inc
AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with annualized sales of more than $25 billion AMETEK has nearly 11000 colleagues working at more than 80 manufacturing facilities and more than 60 sales and service centers in the United States and over 30 other countries around the world
AMETEK DYNAMIC FLUID SOLUTIONS (DFS)
AMETEK Technical amp Industrial Products is a world leader in motors blowers and pumps for mass-transit medical business machine and computer applications It also is a leader in regenerative blowers for pressure and vacuum applications used by broad range of industries
AMETEK supports its customers globally from its manufacturing facilities in Minnesota New York North Carolina Ohio Pennsylvania Italy and China Our brushless DC motors blowers controllers pumps and fans are ideally suited for a wide range of applications including medical instruments robotics pumps compressors offi ce equipment fans machine tools tape drives or any other precise rotary motionair delivery applications
Technical amp Industrial Productsrsquo product line of regenerative blowers for pressure and vacuum applications services the process industrial environmental waste and wastewater industrial industry Typical applications areas include solution agitation and aeration pneumatic conveying part hold-down and pick up part blow off gas and fume extraction and process gas handling
AMETEK Technical amp Industrial Products supplies the solution for unique performance mounting environmental and agency requirements
DYNAMIC FLUID SOLUTIONS
100 East Erie St Kent OH USA 44240USA +1 330-677-3327 - Europe +49 7703 930909 - Asia +86 21
5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Untitled
- Untitled
- Untitled
- Untitled
- Blank Page
- Blank Page
- Blank Page
- Blank Page
-
Table of Contents
A Nine Major Blower Application Areas B Product Dimensional Listing C Industrial Chemical Processing Blowers
DR P15 C57 400 600 HP Regenerative Blower
DR S15 C59 400 HP High Pressure Regenerative Blower
DR 068 C1125 HP Regenerative Blower
D Environmental Chemical Processing Blowers EN 101 amp CP 101 D1
DR 083 C3 5 HP Sealed Regenerative wExplosion-Proof Motor
125 HP Regenerative Blower EN 303 amp CP 303 D3
DR 101 amp CP 101 C5 5 HP Sealed Regenerative wExplosion-Proof motor
33 HP Regenerative Blower EN 404 amp CP 404 D5
DR 202 amp CP 202 C7 10 HP Sealed Regenerative wExplosion-Proof Motor
33 HP Regenerative Blower EN 454 amp CP 454 D7
DR 303 amp CP 303 C9 15 HP Sealed Regenerative wExplosion-Proof Motor
33 HP Regenerative Blower EN 505 amp CP 505 D9 DR 353 amp CP 353 C11 20 25 HP Sealed Regenerative wExplosion-Proof Motor 75 HP Regenerative Blower EN 513 amp CP 513 D11 DR 404 amp CP 404 C13 15 HP Sealed Regenerative wExplosion-Proof Motor 10 HP Regenerative Blower EN 523 amp CP 523 D13 DR 454 amp CP 454 C15 30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
15 HP Regenerative Blower EN 6 amp CP 6 D15 DR 505 amp CP 505 C17 50 HP Sealed Regenerative wExplosion-Proof Motor
20 30 HP Regenerative Blower EN amp CP 633 D17 DR 513 amp CP 513 C19 75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
15 HP Regenerative Blower EN 656 amp CP 656 D19 DR 523 amp CP 523 C21 30 HP Sealed Regenerative wExplosion-Proof Motor
3 HP High Pressure Regenerative Blower EN 757 Single-Phase and CP Options D21 DR 555 amp CP 555 C23 Sealed Regenerative Blower wExplosion-proof Motor
30 40 HP Regenerative Blower EN 757 amp CP 757 D23 DR 6 amp CP 6 C25 30 50 HP Sealed Regenerative wExplosion-Proof Motor
30 50 HP Regenerative Blower EN 808 Single-Phase and CP Options D25 DR 633 amp CP 633 C27 Sealed Regenerative Blower wExplosion-proof Motor
30 40 50 HP Regenerative Blower EN 808 amp CP 808 Three-Phase D27 Sealed Regenerative Blower wExplosion-proof MotorDR 656 amp CP 656
C29 30 40 50 HP Regenerative Blower EN 833 amp CP 833 D29
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor DR 757 amp CP 757 C31 40 50 HP Regenerative Blower EN 858 amp CP 858 D31
75 100 HP Sealed Regenerative wExplosion-Proof Motor DR S7 C33 75 HP High Pressure Regenerative Blower EN 909 amp CP 909 D33
100 150 HP Sealed Regenerative wExplosion-Proof Motor DR 808 amp CP 808 C35 50 75 HP Regenerative Blower EN 979 amp CP 979 D35
200 HP Sealed Regenerative wExplosion-Proof Motor DR 833 amp CP 833 C37 75 100 HP Regenerative Blower EN 14 amp CP 14 D37
200 300 HP Sealed Regenerative wExplosion-Proof Motor DR 858 amp CP 858 C39 75 100 HP Regenerative Blower
DR P9 C41 E Remote Drive (Motorless) Blowers MF573RD E1
150 200 HP Regenerative Blower SL2RD E2 DR S9 C43 DRENCP 404RD E3 150 200 HP High Pressure Regenerative Blower DRENCP 505RD E4 DR 909 amp CP 909 C45 DRENCP 513RD E5 100 150 HP Regenerative Blower DRENCP 523RD E6 DR 979 amp CP 979 C47 DRENCP 6RD E7 150 200 HP Regenerative Blower DRENCP 656RD E8 DR 1233 amp CP 1233 C49 DRENCP 757RD E9 200 HP High Pressure Regenerative Blower DRENCP 858RD E10 DR P13 C51 DRENCP 909RD E11 200 300 HP Regenerative Blower DRENCP 979RD E12 DR S13 C53 DRENCP 1233RD E13 200 300 HP High Pressure Regenerative Blower DRENCP 14RD E14 DR 14 amp CP 14 C55 200 250 300HP Regenerative Blower
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Table of Contents
F Application Specific Blowers Minispiral F1 Insrument Grade Regenerative Blower
Minispiral MDC F3 Variable Flow Regenerative Blower
Minispiral 1224V HDC F5 Variable Flow Regenerative Blower
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy F7 Variable Flow Regenerative Blower
SPIRAL Simplex SL2 F9 Insrument Grade Regenerative Blower
SPIRAL Duplex SL4 F11 Insrument Grade Regenerative Blower
SPIRAL Duplex SL5 F13 Insrument Grade Regenerative Blower
Nautilair F15 DR 404454505513656 F17 Spa Blowers
DR 10RDNTSS10RDNTHS 10RDNT F19 Remote Drive (Motorless) Blowers
MD 101 Magnetic-Drive F21 Regenerative Blower
GVR313 F23 Regenerative Blower
G Accessories Filtration - Inlet Filter (Single Connection) G1 Filtration - Inline Filter (Dual Connection) G2 Filtration - Filter Silencers (Single Connection) G3 Filtration - Filter Element G4 Filtration - Moisture Separator G5 Measurement - Air Flow Meter G7 Measurement - Digital Flowmeter G9 Noise Reduction - Sound Attenuating Enclosure G10 Noise Reduction - InletOutlet Muffler (Single Connection) G11 Noise Reduction - Inline Muffler (Dual Connection) G12 Protection - Relief Valve - Mechanical G13 Protection - Pressure Regulating Diaphram Valve G14 Protection - Gauges G15 System - Variable Frequency Drive G16 System - Air Knives G17 System - 5 Way 3 Port 2 Position Diverter Valve G19 System - Air Flow Switch G21 Pressure amp Vacuum Arrangements G22 H Motor Blower Options I Application Engineering Basics
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 1 Air-Assisted Breathing
Your own imagination and knowledge are probably the best source of in-plant and on-site applications for ROTRON regenerative blowers This guide will help to pinpoint and stimulate your consideration of the many alternative sources we provide to replace costly and maintenance intensive suction and pressure units and systems The nine major application groups are listed and a cross reference of the most common applications by industry will help you identify both identical and similar applications in your industrial operations
Nose
Part
Blower
Blower
Blower
Blower
Blower
Block
Box
BlowerWork Table
Work
Work
Plenum
PneumaticSuction Cups
Mouth
Flotation Tables
Air Slides Air Tables Turning amp Forming Bars
Air Film SupportAir BagsWeb
General Parts Pick-Up General Parts Hold-Down
Vacuum Manipulator Flotation Tables
Throat
ManufacturingPARP Respiration
MiningPARP Respiration
Application 2 Air-Assisted Inflation or SupportMaterial HandlingAir SlidesAir TablesCarbon Black Car Unloading
Paper ProcessingFlotation TablesForming BarSheet FlutteringTurn Bars
TextileGarment Flotation Tables
Water Pollution ControlPollution ContainmentWaterway Management
Application 3 Air-Assisted Vacuum Pick-Up or Hold-DownManufacturingBag Filling EquipmentCutting TablesPackaging EquipmentVacuum ManipulatorsCorrugated and Paperboard BoxesFlexible Packaging - Paper Plastic Aluminum Foil Textile Packaging and Steel StrappingRigid PackagingBeverage ContainersCosmetic and Toiletry ContainersBlister PacksPharmaceutical PackagingFood PackagingSterile Medical Device PackagingLabelsPressure Sensitive Tape
Paper or Plastics HandlingCutting TablesDiaper Making EquipmentPrinting Presses
TextileGarment Cutting TablesYarn Guiding and TensioningYarn AspirationCarboard Case Erector
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 4 Air amp Gas Sampling Boosting or Circulating
Fluid Bed Regeneration Transmissometer Lens Purging
Natural Gas Boost Air amp Gas Sampling
Combustion Air Boost
Pressurized Cabinet Vacuum Pull-Through Cabinet
Soil Vapor Extraction ampLandll Gas Recovery Vent Header O-Gassing
Fume amp Smoke Removal Digester Gas Collection
Air Pollution ControlAir SamplingAir Stream Release MonitoringFire Prevention Air SamplingFlue Gas Sampling
FoundryCombustion Air Boost
InstrumentationGlove Box PressurizingIncubator Air CirculationWeather Measurement Sampling
ManufacturingCombustion Air BoostNatural Gas BoostOil Demisting
PharmaceuticalClean Room Air CirculationOxygen Generator
Plastics HandlingDesiccant Dryer Bed Regeneration
Application 5 Electronic CoolingInstrumentationEngineMotor CoolingFilm Development System CoolingLamp Bank CoolingSmall Enclosure Cooling
Application 6 Gas Vapor amp Fume Recovery Venting amp TreatmentPharmaceuticalSterilization Gas (ETO) Recovery
ReneriesCentrifuge Venting
Water Pollution ControlDigester Gas Collection
AgriculturalMethane Gas RecoveryChemical ProcessingVent Header O-Gassing
EnvironmentalGasoline Vapor RecoveryLagoon Gas RecoveryLandll Gas RecoveryRadon Gas CollectionSoil Vapor Extraction
FoundryLost Foam O-Gassing
Manufacturing - Plant ServicesCabinet Fume VentingEnvironmental Test Chamber VentingLaser Smoke RemovalWeld Smoke Removal
Natural Gas
Blower
Blower
Blower
Blower
BlowerFilter
Blower
Blower Flame
Digester
Scrubber ChemicalTank
Treatment System
Electronics
Gas
CombustionChamber
BlowerBlower Blower
Light Beam
Lens
Stack
Lens
Natural GasFurnace
Minispiral
Instrument
Blower
Electronics
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 7 Solid Material Transporting Separation amp CollectionFoundrySand Reclamation
Manufacturing - Waste ControlChip Dust amp Particle RemovalLiquid amp Solvent RemovalPaper Plastic Film amp Textile (Trim) Removal
Material HandlingAir SlidesBlast CleaningDilute Phase ConveyingPneumatic Tube
PackagingBag Filling
Application 8 Parts Blow-Off amp Drying
Application 9 Solution amp Media Agitation amp AerationAquacultureAquarium Fish Farm Hatchery amp Pond Aeration
Groundwater Sparging
ManufacturingConcrete Fluid Bed AerationElectroplating Tank Agitation
Material HandlingFluidized Beds
RecreationCommercial Spa Aeration
Water ManagementBoat Dock amp Dam Face Deicing
Water Pollution ControlUV Tube AgitationWatewater Filter BackwashWastewater Treatment Tank Aeration
ManufacturingConveyor Belt Blow-OElectroplating Fume GuidingElectroplating Parts DryingElectroplating Solution Blow-BackFlat or Irregular Metal Parts DryingWire Drying
Aqueous Precision CleaningAutomotive Parts DryingSemiconductor Board Drying
Food ProcessingBatter Blow-OBottle amp Can DryingLabel DryingSalt Spice amp Flour Blow-O
Dilute Phase Pneumatic Conveying Pneumatic Tube
Paper Plastic Film amp Textile (Trim) Removal
General Parts Blow-O amp Drying Solution Blow-Back
Wastewater Treatment Tank Aeration Groundwater Sparging
Electroplating Tank Aeration Commercial Spa Aeration
Bin Pad amp Fluidized Bed Aeration Boat amp Dock Deicing
General Material Separation amp Collection
PressureBlower
Blower
Blower CollectionChamber
Blower
Blower
Blower
Blower
Blower
ProductBin Aerator
(Air Pads)
Blower
Blower Dock
Water
Hot Tub
Plating Bath
Spargers
Blower
Blower Ground Level
Soil
Water Table
Plating Tank
Air Knife
Hoist
Blower
Air Knife
TubeCarrier
Ejector
Bin
RotaryAirlock
DischargeTo Process
Cyclone
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Product Dimensional Listing
Blowers Shipping Wt (LBS) Carton Length (In) Width (In) Height (In)
DREN
068 16- 12 12 12
083 18- 12 12 12
101 3047 16 15 14
202 30- 16 15 14
303 4252 16 15 14
353 54- 21 16 16
404 6481 21 16 16
454 6084 21 16 16
505 8292 21 16 16
513 7699 24 12 22
523 112126 24 16 22
555 96- 21 16 16
633 241288 25 18 20
656 110117 24 16 22
6 148167 25 18 20
S7 206- 25 18 20
757 131158 25 18 20
808 285287 34 23 26
833 269297 44 29 37
858 280338 34 23 26
S9 P9 400- 34 23 26
909 373524 34 23 26
979 345533 34 23 26
1233 400- 34 23 26
14 620737 43 28 33
S13 P13 687- 43 28 33
S15 P15 909- 43 28 43
Minispirals (SE212) 2- 8 8 6
Nautilairs (NC33) 18- 16 15 14
Spiral (SL245) 42- 16 15 14
Note Model weight will vary by HP and voltage Refer to individual specication sheets to verify
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 B 1Customer Service Fax +1 2152561338 wwwametekdfscom
Industrial Chemical Processing Blowers AMETEK Dynamic Fluid Solutionsrsquo ROTRON brand has long been a world leader in regenerative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial DR (Domestic Regenerative) blowers include
Rugged cast aluminum housing cover impeller and muffler tower Removable cast iron flanges bolted to a sheet metal manifold TEFC motors on single-ended models ODP motors on all double-ended models Carbon steel shaft and zinc plated hardware Permanently sealed motor bearings for 20000-25000 hours life
Our CP (Chemical Processing Regenerative) blowers include
Chem-ToughTM surface conversion corrosion resistant treatment for aluminum castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Chemical Duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
OUTIN
(2) PLACES
85
671 99
302 100
616
155
029
39
23
641
097
371 94
152
60 DIA
35 DIA
(2) MTG HOLES
162
5876
174
216
9
553
1405
100 OD
8
22
25
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR068DJ9Y
Specification Units 081657
Motor Enclosure - Shaft Mtl - TEFC - CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 16 Kg 73
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 1 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 13 SCFMbull Maximum pressure 135 IWGbull Maximum vacuum 135 IWGbull Standard motor 18 HP TEFCbull Cast aluminum blower housing impeller amp cover slip-on steel flangesbull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Various horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR068 DR068
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 2 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
789
200
4
125
8492156
702
328 120833
1783
INOUT
448
113
8
139
685174
037
295
650
749
1651
736
DR083DC9Y - 036862
101(2 MTG HOLES)
397 DIA305
318
(2 P
LACE
S)
94
353
1869NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR083DC9Y
Specification Units 081572
Motor Enclosure - Shaft Mtl - TEFC -CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 18 Kg 82
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 3 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 24 IWGbull Maximum vacuum 232 IWGbull Standard motor 18 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR083 DR083
0 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
600 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
60
0
50
100
0
50
100
100
0
100
50
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 4 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
0 2 10 12 14 16 18 20 220
4 86
50
0
0 2 10 12 14 16 18 20 220
4 86
Temperature curves are based on standard model
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
115292
211
94
236
131
824 519
37
931
41102 MTG HOLES
312
6579
165741188
106 27
11
1997740
044
1
ROTATIONDIRECTION
1-11 12FEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR101Y9M DR101Y72M DR101Y86M CP101FB91MLR
Specification Units 038936 038937 038938 038225
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 033 033 033 033 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 3417 131206 06 13-1206 Service Factor - 135 125 125 125 Max Blower Amps Amps (A) 3417 13065 04 13065 Locked Rotor Amps Amps (A) 16482 64-5829 42 64-5829 NEMA Starter Size - 0000 00-0000 00 00-0000
Shipping Weight Lbs 30 30 30 30 Kg 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 5 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum ow 31 SCFM
bull Maximum vacuum 285 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR101 DR101
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 6 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
1178299
100
0
64 83
1130
963
394100
72
39
127
114
254
518
252 327
286
22
131
283
044
245
45
503153
81220628912263
STANDARDROTATION88
398 DIA10
1 14-11 12 NPSCSTRAIGHT THREAD(2X) CAST IRON FLANGES
(4X)
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR202Y9M DR202Y72M DR202Y86M CP202AE72MLR CP202FA91MLR
Specification Units 080564 080565 080566 038953 038227
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 33 033 033 033 033 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 3417 1206 05 1206 1206 Service Factor - 135 135 135 135 135 Max Blower Amps Amps (A) 5226 154077 057 154077 154077 Locked Rotor Amps Amps (A) 16482 6432 26 6432 6432 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 30 30 30 30 30 Kg 136 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 7 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 40 IWGbull Maximum vacuum 35 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR202 DR202
0 5 10 15 20 25 30 35 40 45 50 55
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 8 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
101(4) MTG HOLES
394
1001
2065
813
L10
0
254
519
132
1
245
64
327
831
113
287
961
2446
45
283
50
127
114
3
72
144
366
112
044
DR303AE9MDR303AE72MDR303AE86M
MODEL L (INMM)1186301211629461193303
891
2263
2 ROTATION DIRECTION
398 DIA
FEMALE THREADBOTH PORTS
1 14 - 11 12 NPSCNOTES
1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR303AE9M DR303AE72M DR303AE86M CP303FA91MLR
Specification Units 038841 038842 038843 080148
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 05 05 05 05 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 6231 13-1206 06 13-1206 Service Factor - 125 125 125 125 Max Blower Amps Amps (A) 63 163083 07 163083 Locked Rotor Amps Amps (A) 21105 10-9246 42 10-9246 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 34 42 42 42 Kg 154 191 191 191
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 9 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 48 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR303 DR303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 10 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
IN
OU
T
L12
22
311
31579
37595
12(4) MTG HOLES
1275324
513
622
115
555
512130
1018
Oslash613
041
10
356
175
292
141
130
90
158 44
156
258BOTH PORTS MODEL
DR353BR9M
DR353BR72M
L (INMM)
1397355
125317
8932268
47 DIA
1 12 - 11 12 NPSC THREAD
ROTATION DIRECTION1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR353BR9M DR353BR72M DR353BR86M CP353BR72MLR CP353FD72MLR
Specification Units 080554 080555 080556 081562 081612
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 075 075 075 075 075 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three 60 Hz Three 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 10050 3015 096 3015 3015 Service Factor - 115 125 125 125 125 Max Blower Amps Amps (A) 126 35175 10 35175 35175 Locked Rotor Amps Amps (A) 596298 15276 61 15276 15276 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 60 54 54 54 54 Kg 272 245 245 245 245
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 11 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 34 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR353 DR353
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 12 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
375
167
424
119(4) MTG HOLES
2921115
512
893
130
2268
L
4125
046
2816
0
121
830
94
718
182
4
305792 953
12633208
041 89
DR404AL58MDR404AL72MDR404AL86M
MODEL L (INMM)144136601418360213383399
FEMALE THREADBOTH PORTS
1032616
1
1 12 - 11 12 NPSC
47 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA KNOCK-OUT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR404AL58M DR404AL72M DR404AL86M CP404CU72MLR
Specification Units 037407 037406 037408 038233
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 10 10 10 10 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 11457 3015 12 3015 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 145725 4020 14 4020 Locked Rotor Amps Amps (A) 7035 210105 76 210105 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 69 64 64 64 Kg 313 29 29 29
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 58 IWGbull Maximum vacuum 50 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR404 DR404
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 14 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
IN OUT
475
325 178
1256
15
431
135
L
120
7
418
106
436
111524
133
20
69
175
114
475120
290
51
318
042 11
FEMALE THREAD
(6) MTG HOLES
MODEL
DR454R58MDR454R72M
L (INMM)
14473671331338
83 45
110
319
343
BOTH PORTS
125
10302616
451143
59 DIA
ROTATION DIRECTION
1 12 - 11 12 NPSC
1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR454R58M DR454R72M DR454R86M CP454EZ72MLR
Specification Units 080481 080480 080482 080491
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 5060 Hz Three - 5060 Hz Three - 5060 Hz Three - 5060 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 15678 4623 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 189 5226 21 5226 Locked Rotor Amps Amps (A) 8442 3216 128 3216 NEMA Starter Size - 10 0000 00 0000
Shipping Weight Lbs 73 60 60 60 Kg 331 272 272 272
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 15 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 60 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR454 DR454
0 15 30 45 60 75 90 105 120 135 150 1650
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
2240 25 51 76 102 127 153 178 204 229 255 280
15 30 45 60 75 90 105 120 135 150 165
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
00
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 16 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
IN
L
144
3
356
1418
59 DIA
(4) MTG HOLES
475
1030
1170 REF
725
191
37
REF
C B
1359 DIA
15
MODEL DR505AS58M
DR505AS72MDR505AS86MDR505K58MDR505K72M
1563397
1563397
14753741438365170431
L (INMM)
425108437111
437111
463117
463117
B (INMM)564143
525133
564143518131
C (INMM)
518131
FEMALE THREADBOTH PORTS
OUT
45
1143904
3602
366
5
184
2
485
1207
2616
2972
94
1824
3452
1 12 - 11 12 NPSC
ROTATION DIRECTION
1
718 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR505AS58M DR505AS72M DR505AS86M DR505K58M DR505K72M CP505FE72MLR CP505CT72MLR
Specification Units 037542 037543 037544 081882 037551 038239 038237
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS CHEM TEFC - SS Horsepower - 20 20 20 30 30 30 20 Voltage AC 115230 230460 575 115230 230460 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F F NEMA Rated Motor Amps Amps (A) 18291 5427 23 256128 7638 7638 5427 Service Factor - 115 115 115 115 115 115 115 Max Blower Amps Amps (A) 24115 735 30 2814 8844 8844 6834 Locked Rotor Amps Amps (A) 13869 3819 21 19497 8844 8844 3819 NEMA Starter Size - 10 0000 00 150 00 00 0000
Shipping Weight Lbs 97 82 84 91 86 86 82 Kg 44 372 381 413 39 39 372
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 17 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 73 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
0 15 30 45 60 75 90 105 120 135 150 16515 30 45 60 75 90 105 120 135 150 165 0
0
50
100
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
50
100
0
50
100
0
50
100
0
37
75
112
149
187
224 2240 25 51 76 102 127 153 178 204 229 255 280
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
0
0
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 18 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
OUTIN
182
1421
160
6
15
408
507
413
88
24
48
128
05
ROTATION
(4) MTG HOLES
106
61
224
122
BOTH PORTSFEMALE THREAD 325
360
937
18
1369346
372
129
1142896
5501397
1388
35261
59 DIA
1 12 - 11 12 NPSC
13
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR513R72 DR513R58 DR513R86 CP513EZ72LR
Specification Units 037217 037209 037773 038241
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 4623 16884 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 525 1995 185 525 Locked Rotor Amps Amps (A) 4321 12060 13 4321 NEMA Starter Size - 0000 10 00 0000
Shipping Weight Lbs 76 95 76 76 Kg 345 431 345 345
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 19 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 80 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR513 DR513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 20 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
IN OUT
3462
1397
3597
(4) MTG HOLES
564
220
7
1206
2901
3251
FEMALE THREADBOTH PORTS
1363
550
222
869
475
128
1142
L16
12
409
5
419 10
8
47
1194
1416
1443658
150
05
13
1421
3581
695
425
108
523
133
MODELDR523K72DR523K58
1591404119314905
L (INMM)
1 12 - 11 12 NPSC
ROTATION DIRECTION
59 DIA
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR523K72 DR523K58 DR523K86 CP523CS72LR
Specification Units 037210 037211 037772 038243
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-SS Horsepower - 3 3 3 3 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three-60 hz Single-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 88-8643 27135 34 88-8643 Service Factor - 115 10 10 115 Max Blower Amps Amps (A) 89445 3015 34 89445 Locked Rotor Amps Amps (A) 913457 19698 364 913457 NEMA Starter Size - 00 151 0 00
Shipping Weight Lbs 112 145 112 112 Kg 508 658 508 508
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 21 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 158 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR523 DR523
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 22 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
MODEL
DR555K72DR555K58
DR555CK72
L (INMM)
1744443
16124091738441
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
1506
1493L
Part Model Number
DR555CK72 DR555CK86 DR555K72 DR555K58 DR555K86 CP555CS72MLR
Specification Units 081100 081102 081099 081098 081101 038245
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 40 40 30 30 30 30 Voltage AC 230460 575 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 105 41 7638 256128 3 7638 Service Factor - 115 115 115 10 10 115 Max Blower Amps Amps (A) 1365 42 8844 2814 34 8844 Locked Rotor Amps Amps (A) 9447 80 8844 19497 70 8844 NEMA Starter Size - 10 0 00 151 0 00
Shipping Weight Lbs 113 137 96 91 90 90 Kg 513 621 435 413 408 408
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 23 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 92 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR555CK72DR555K72DR555K58
LegendPressureSuction
DR555CK72DR555K72DR555K58
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 24 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
OUTIN
486
241
1234L
95
165
163
441
5
1463
698 70 200508
40
215
98
50
848334 401016
FEMALE THREADBOTH PORTS
3201016
2032800
MODEL
DR6D89
DR6K72
L (INMM)
18004572
18004572
MUFFLER
2 - 11 12 NPSC
1
562 DIA
ROTATION DIRECTION
419
177 178
850
215
9
102
141
75
58(4) MTG HOLES
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR6D89 DR6D5 DR6D86 DR6K72 CP6FF72LR HiE6D89
Specification Units 027578 036212 027579 027600 038253 038071
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 50 50 50 30 50 50 Voltage AC 230460 230 575 230460 230460 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 11255 21 48 133-126 173-15678 173-15678 Service Factor - 115 10 115 115 115 115 Max Blower Amps Amps (A) 168 25 54 126 15-14874 15-14874 Locked Rotor Amps Amps (A) 165-15576 124 60 10653 165-15576 165-15576 NEMA Starter Size - 11 15 1 10 11 11
Shipping Weight Lbs 148 156 148 132 148 148 Kg 671 708 671 599 671 671
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 25 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 912 IWGbull Standard motor 50 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
designs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR6D89DR6K72DR6D5
LegendPressureSuction
DR6D89DR6K72DR6D5
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
0
50
100
52248 1 pc
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 26 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
NOTES
1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
98 (2X)249
118113000
20
51
322
10502667
818
6101549
6221580
IN OUT
DIRECTIONOFROTATION
103262
189
448
11
4881240
266676 1841
4676
17244 4380
1806 4587
13163343
105
9 26
90
16684237
2 NPSCFEMALE THREADBOTH PORTS
INMM
INCLUDES INLET FILTER
Part Model Number
DR633AY72M DR633AY86M DR633D89M CP633FG72LRM
Specification Units 081691 081693 081689 081695
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 75 75 5 75 Voltage AC 230460 575 208-230460 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 23-21105 84 169-15376 23-21105 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 198-189 79 15-13668 198-189 Locked Rotor Amps Amps (A) 17085 55 165-15576 17085 NEMA Starter Size - 21 1 1-10 21
Shipping Weight Lbs 241 241 223 241 Kg 1093 1093 1012 1093
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 27 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 275 IWGbull
bull Maximum vacuum 190 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR633AY72MDR633D89M
LegendPressureSuction
DR633AY72MDR633D89M
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 28 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
414
151
738
25
059
1052 140
1512384
L
556
141
(4X) MTGHOLES
15
15423905
746
190
456
116
Oslash7191826
225 0
6417
3
114202896
492125
572
2 NPSCSTRAIGHT THDSBOTH PORTS
MODEL L (INMM)
DR656CK72XDR656K72X
1750444516004064
12813254
551
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR656CK72X DR656CK86X DR656CK5X DR656K72X DR656K58X CP656CR72XLR
Specification Units 080582 080583 080584 080602 080603 080065
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC-CS TEFC - CS TEFC - CS CHEM TEFC-SS
Horsepower - 35 35 35 30 30 35Voltage AC 230460 575 230 230460 115230 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 10050 40 18 7437 29145 10050 Service Factor - 115 10 115 115 10 115 Max Blower Amps Amps (A) 11457 52 18 945 278139 11457 Locked Rotor Amps Amps (A) 9447 80 115 5427 17286 9447 NEMA Starter Size - 10 0 1 00 1510 10
Shipping Weight Lbs 110 114 101 103 114 110 Kg 499 517 458 467 517 499
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 29 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull
bull Maximum vacuum 89 IWGbull Standard motor 40 HP TEFCbull
bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
bull Cast iron cover for additional noise resonance
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 30 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
174
444
3
L
504
16
20
571
702
20
281
153389
167
426
063
R03179
CL OF BLOWER9
23
277 575
84
657
1675
128
50
50
71
145
178
ROTATIONDIRECTION
234
70 146 21
MODEL
DR757CK72X
DR757CK86X
DR757D89XDR757D86X
DR757D5MX
1855471
18554711855471
1855471
L (INMM)
5601422
2621031
163414
12733233
1
2 12 NPSCFEMALE THREADSBOTH PORTS
1855471
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (26) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR757CK72X DR757CK86X DR757D89X CP757FF72XLR CP757CR72XLR
Specification Units 081172 081173 081169 081178 081179
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS CHEM TEFC-SS Horsepower - 40 40 50 50 40 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 hz Three - 60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 105 40 126 126 105 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 126 42 15576 15576 126 Locked Rotor Amps Amps (A) 9447 80 19497 19497 9447 NEMA Starter Size - 10 0 10 10 10
Shipping Weight Lbs 131 128 140 140 131 Kg 594 581 635 635 594
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 31 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 83 IWGbull
bull Maximum vacuum 75 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg 0
C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR757D89XDR757CK72X
LegendPressureSuction
DR757D89XDR757CK72X
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22451 102 153 204 255 306 357 408 459 510 561
37
75
112
149
187
224
0
0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 32 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
2303
700
1100
200
OUTIN
400
800
494
1150
322
644
1638
588
1778 508
2794
818
101
6
1255
2032
2921
1636
1494
143(4) MTG HOLES
A
A
FEMALE THREADBOTH PORTS
FEMALE THREADBOTH PORTS
SECTION VIEW A-A
585
164
441
76
803204
4161
825
558
147
820
96
563 DIA
2 - 11 12 NPT
2 - 11 12 NPT
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS7X72 DRS7X86
Specification Units 036085 036144
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 19497 78 Service Factor - 115 10 Max Blower Amps Amps (A) 2412 96 Locked Rotor Amps Amps (A) 16683 66 NEMA Starter Size - 11 1
Shipping Weight Lbs 206 206 Kg 934 934
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 33 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 75 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS7
LegendPressureSuction
DRS7
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 34 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
IN OUT
L
536
421
12
143(8) MTG HOLES
875222
191485
18734757
09
229
359
912
117
529
8
C
35889
177870
FEMALE THREADBOTH PORTS
MODEL
DR808D89MXDR808AY72MX
L (INMM)2223564619314905
17434427
1575
14763749
4001
738187585
21622385685
562 DIA
1
2 12 - 8 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR808AY72MX DR808AY86MX DR808D89MX CP808FG72MXLR HiE808AY72MX
Specification Units 081222 081224 081225 081233 081228
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 75 75 50 75 75 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 17889 72 173-15678 17889 17889 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 108 147 2814 2814 Locked Rotor Amps Amps (A) 12060 60 15276 12060 12060 NEMA Starter Size - 11 1 10 11 11
Shipping Weight Lbs 285 242 195 285 301 Kg 1293 1098 885 1293 1365
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 35 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR808AY72MXDR808D89MX
LegendPressureSuction
DR808AY72MXDR808D89MX
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 36 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
NOTES
FILTER 515255 INCLUDED1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
MTG HOLEDETAIL
(4X)
20
51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
193
849
23
84213
5241331
ROTA
TION
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
IN OUT
1881 4778
17638 44801
104
426
52
19134859
1050 DIA2667
13983551
2406096
8712212
Part Model Number
DR833BB72M DR833BB86M DR833AY72M DR833AY86M CP833FH72MLR
Specification Units 081702 081704 081699 081701 081710
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 10 10 75 75 10 Voltage AC 230460 575 230460 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 31-2814 96 23-21105 84 31-2814 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 26-2412 89 212-19296 77 26-2412 Locked Rotor Amps Amps (A) 19095 73 17085 68 19095 NEMA Starter Size - 21 1 21 1 21
Shipping Weight Lbs 269 269 260 260 269 Kg 122 122 1179 1179 122
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 37 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 258 IWGbull
bull Maximum vacuum 174 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR833BB72MDR833AY72M
LegendPressureSuction
DR833BB72MDR833AY72M
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 38 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
902
OUT IN
FEMALE THREADBOTH PORTS
355
1860
400
(4) PLACES
19750
200
1016
4724
6811753
13533437
22345674
119
218
155
39
101
825
91
1000
13003302
2563
7091803
831
211
1116
829
67
101
325
73
641626
9992525
1905 X 508
L
MODEL DR858AY72WDR858BB72W
L (INMM)230658572319589
8492156
175950
2413
ROTATION DIRECTION
2 12 - 8 NPSC
75 X 200 SLOT
508
445
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR858BB72W DR858BB86W DR858AY72W CP858FH72WLR HiE858BB72W
Specification Units 038740 038742 038738 038749 038743
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 10 10 75 10 10 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 2613 105 17889 2613 2613 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 12 2814 2814 2814 Locked Rotor Amps Amps (A) 16281 65 12060 16281 16281 NEMA Starter Size - 21 1 11 21 21
Shipping Weight Lbs 280 280 264 280 280 Kg 127 127 1197 127 127
Model (Base Mount) - DR858BB72X DR858BB86X DR858AY72X Part Number (Base Mount) - 038735 038737 038736
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 39 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 125 IWGbull Maximum vacuum 1048 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR858BB72WDR858AY72W
LegendPressureSuction
DR858BB72WDR858AY72W
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 40 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
925
12003048
A
A
816
207
3
218
1 RE
F
1000
7091801
355902
FEMALE THREADBOTH PORTS
(4) PLACES
180
0 D
IA
457
2
400 DIA SLIP-ON1016
L
2349
142
10882764
554
100
025
4
254
756192
SECTION VIEW A-A
MODEL DRP9BM72CDRP9BL72C
L (INMM)3175806533448494
2
1
2 12 - 8 NPSC
ROTATION DIRECTION
56 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 PRESSURE OUTLET CONNECTION2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP9BM72C DRP9BM72D DRP9BM86C DRP9BM86D DRP9BL72C DRP9BL72D
Specification Units 037033 036275 037040 036276 036512 036513
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP-CS ODP - CS ODP-CS ODP - CS Horsepower - 20 20 20 20 15 15 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 49245 49245 20 20 37185 37185 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 6030 6030 222 222 5025 5025 Locked Rotor Amps Amps (A) 306153 306153 115 115 256128 256128 NEMA Starter Size - 32 32 2 2 22 22
Shipping Weight Lbs 400 408 464 408 380 418 Kg 1814 1851 2105 1851 1724 1896
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 41 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 116 IWGbull Maximum vacuum 95 IWGbull Standard motor 20 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP9BM72CDRP9BL72C
LegendPressureSuction
DRP9BM72CDRP9BL72C
0 80 160 240 320 400 480 560 640 720 800 880 0
0 136 272 408 544 680 816 951 1087 1223 1359 1495
80 160 240 320 400 480 560 640 720 800 880
136 272 408 544 680 816 951 1087 1223 1359 14950
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 42 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
1050 925
1200
223
3048
A
A
218
1
7091801
355902
XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX
FEMALE THREADBOTH PORTS
L
2349
100
554
254
816
207
3
56 (142) DIA (DRS9BL72)
500127756
19051000
254SECTION VIEW A-A
L (INMM)
31758065
33448494
MODEL
DRS9BM72
DRS9BL72
180
457
2
2 12 - 8 NPSC
60 X 135 SLOT(4) (DRS9BM72)
ROTATION DIRECTION
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS9BM72 DRS9BM86 DRS9BL72
Specification Units 037032 037041 036514
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 20 20 15 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 4824 20 3618 Service Factor - 115 115 10 Max Blower Amps Amps (A) 5628 204 5628 Locked Rotor Amps Amps (A) 288144 115 222111 NEMA Starter Size - 32 2 22
Shipping Weight Lbs 446 446 418 Kg 2023 2023 1896
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 43 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 206 IWGbull Maximum vacuum 157 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS9BL72CDRS9BM72C
LegendPressureSuction
DRS9BL72CDRS9BM72C
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
50
100
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 44 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
--
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
IN MM
NOTES1 TERMINAL BOX CONNECTOR HOLE 125 (318) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
Part Model Number
DR909BE72W DR909BE86W DR909BB72W DR909BB86W CP909FJ72WLR HiE909BE72W
Specification Units 081737 081739 081738 081744 038632 081735
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 15 15 10 10 15 10 Voltage AC 208-230460 575 230460 575 208-230460 208-230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 Hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 415-376188 146 2613 105 415-376188 415-376188 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 4221 17 3417 130 4221 4221 Locked Rotor Amps Amps (A) 318159 164 16281 65 318159 318159 NEMA Starter Size - 22 2 21 1 22 22
Shipping Weight Lbs 400 400 400 400 400 400 Kg 1814 1814 1814 1814 1814 1814
Model (Base Mount) DR909BE72X DR909BE86X DR909BB72X DR909BB86X Part Number (Base Mount) 038622 038626 038623 080183
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 45 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 137 IWGbull Maximum vacuum 106 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards when properly piped and
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR909BE72WDR909BB72W
LegendPressureSuction
DR909BE72WDR909BB72W
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 46 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
OUT IN
ROTATIONDIRECTION
1303302
952413
L
11252858
193490298
2489
204
518
216
88
428
8B
C D
E
L (INMM)MODEL
DR979BH72W
DR979BE86W
D (INMM) E (INMM)2907366
25386446
25816556
1319335
9882509
9882509
B (INMM) C (INMM)
12253112
10252604
10252604
8382129
8382129
8092055
6881748
6881748
11502921
DR979BE72W
1
4 NPSCPORTS
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 109 DIA (DR979BE72W)
1375 DIA (DR979BH72W)2 75 (191) X 200 (508) 4X MOUNTING SLOTS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR979BH72W DR979BE72W DR979BE86W DR979BH86W CP979FJ72WLR HiE979BE72W
Specification Units 080718 080704 080702 080719 081777
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 20 15 15 20 15 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - H H H H H H NEMA Rated Motor Amps Amps (A) 4623 4422 146 4623 4422 4422 Service Factor - 115 125 115 115 125 125 Max Blower Amps Amps (A) 6030 5226 21 6633 5226 5226 Locked Rotor Amps Amps (A) 294147 290145 93 294147 290145 290145 NEMA Starter Size - 32 22 2 32 22 22
Shipping Weight Lbs 350 300 300 350 300 300 Kg 1588 1361 1361 1588 1361 1361
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 47 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 1100 SCFMbull Maximum pressure 80 IWGbull Maximum vacuum 87 IWGbull Standard motor 15 HP TEFCbull Cast aluminum blower housing impeller amp cover cast iron flanges
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Chemical duty high efficiency inverter duty or industry-specific designsbull Vairous horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Slip-on or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR979BE72WDR979BH72W
LegendPressureSuction
DR979BE72WDR979BH72W
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 48 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
200 HP High Pressure Regenerative Blower
NOTES1 TERMINAL BOX CONNECTOR HOLE 138 (35) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
Part Model Number
DR1233BH72W DR1233BH86W CP1233GD72LRW
Specification Units 081375 081377 081379
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 20 20 20 Voltage AC 208-230460 575 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 51-4623 184 51-4623 Service Factor - 15 115 15 Max Blower Amps Amps (A) 50-4623 178 50-4623 Locked Rotor Amps Amps (A) 397199 159 397199 NEMA Starter Size - 32 2 32
Shipping Weight Lbs 400 400 400 Kg 1814 1814 1814
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 49 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 255 IWGbull Maximum vacuum 175 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR1233
LegendPressureSuction
DR1233
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
Inlet Filter part 522948
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 50 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
NOTES1 081801 DRP13BP72C MODEL SHOWN2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
PART NUMBER
081801
113028702
94423976
47211995
43010922
84721514
C
E
122131013
355790348
145436932
95024130
94824079
130533134
57314554
40010160
2050
10462657
177845171
FLEX TUBING (2X)
4rdquo - 8 NPT (2X)FEMALE THREAD
6rdquo - 8 NPSC FEMALE1533886 DEEP
125231788
G
75 X 200 SLOT191 X 508 (4X)
H
ROTATIONDIRECTION
081802
081804
081805
081798
081797
DRP13BP72C
DRP13BP72D
DRP13BP86C
DRP13BP86D
DRP13BM72C
DRP13BM72D
1130287
1130287
1130287
1130287
105526797
105526797
250163525
250163525
250463525
250463525
242661611
242661611
125231788
125231788
125231788
125231788
107727343
107727343
2508
2508
2508
2508
1383505
1383505
MODEL C INMM H INMM G INMM E INMM
INMM
Part Model Number
DRP13BP72C DRP13BP72D DRP13BP86C DRP13BP86D DRP13BM72C DRP13BM72D
Specification Units 081801 081802 081804 081805 081798 081797
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS Horsepower - 30 30 30 30 20 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 7035 7035 28 28 49245 49245 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 380190 380190 174 174 306153 306153 Max Blower Amps Amps (A) 11055 11055 36 36 6432 6432 NEMA Starter Size - 33 33 3 3 32 32
Shipping Weight Lbs 687 687 687 687 592 592 Kg 3116 3116 3116 3116 2685 2685
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 51 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 103 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP13BP72CDRP13BM72C
LegendPressureSuction
DRP13BP72CDRP13BM72C
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 52 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
944
1130
472
112
8
107743
847
1454
9501
081363
OUT
IN
1233
2736
2398
2870
1199
286
525
04
63621
51
109
2
SECTION VIEW A-A
35579035
197
950
27
3693
274
3462 2413
4241077
3132
204
952
04
BOTHPORTS
1
SLOTS75x200(19x508)(4) PLACES
3
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4rdquo-8 NPSC FEMALE THREAD BOTH PORTS3 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS5 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING6 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS13BP72 DRS13BP86 DRS13BM72
Specification Units 081800 081803 081799
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 30 30 20 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 7839 28 49245 Service Factor - 115 115 115 Max Blower Amps Amps (A) 8040 32 70153 Locked Rotor Amps Amps (A) 380190 174 306153 NEMA Starter Size - 33 3 32
Shipping Weight Lbs 646 646 562 Kg 293 293 2549
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 53 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 195 IWGbull Maximum vacuum 132 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS13
LegendPressureSuction
DRS13
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 54 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
11001311
128
8
17004318
MODELDR14DW72MW
L (INMM) D (INMM)19850331558014
L
751905
29257430
276
701
0972
2477
300762
2794
17574463
234
659
59
327
2
333
9652451
11572939
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
D
SEE NOTE 1
2332 DIA5923
1531 DIA3889
SEE NOTEOUT IN 1
NOTES1 LIFTING SLOT 100 X 170 (254 X 432)2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR14DW72MW DR14DW86MW DR14DT72MW DR14BH72MW CP14FK72MWLR HiE14DW72MW
Specification Units 081476 081479 081483 081480 081490 081497
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 30 30 25 20 30 30 Voltage AC 230460 575 230460 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 6633 265 5829 4623 6633 6633 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 9045 328 9045 6030 9045 9045 Locked Rotor Amps Amps (A) 430215 172 304152 294147 430215 430215 NEMA Starter Size - 33 3 33 32 33 33
Shipping Weight Lbs 696 694 650 600 696 696 Kg 3157 3148 2948 2722 3157 3157
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 55 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 120 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 56 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
141
411
42
588
A
2404 REF
969
296
4
1562
1250
1034
OUT IN
SECTION VIEW A-A
1238
295
3
10114
233
0 D
IA
121
2 320
1 RE
F
OU
T IN
359
2
149
4
290
1
752
9
2461
6106
3145
3967
3175
2626
750
1
591
8
307
8
813
1
A
1129
1429363
1725
11252858
43822868
39823982714281 DIA
(2 PLACES)
19(4) PLACES
508
300762
1
2
3
75 X 200 SLOTNOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 PRESSURE CONNECTION 6-8 NPSC FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP15EE72C DRP15EE72D DRP15BQ72C DRP15BQ72D DRP15BQ86C DRP15BQ86D
Specification Units 081499 081629 081501 081500 TBD TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP - CS ODP - CS ODP - CS ODP - CS Horsepower - 60 60 40 40 40 40 Voltage AC 230460 230460 230460 230460 575 575 Phase - Frequency - Three-60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 14070 14070 9648 9648 384 384 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 870435 870435 630315 630315 540270 540270 Max Blower Amps Amps (A) 17085 17085 16080 16080 64 64 NEMA Starter Size - 54 54 43 43 3 3
Shipping Weight Lbs 1025 1025 923 923 923 923 Kg 4649 4649 4187 4187 4187 4187
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 57 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 115 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 58 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
2469
A
OU
T
IN
IN
OUT
A
SECTION VIEW A-A
972
BOTHPORTS
1
4
2
5
3
1082743
12503175
1563962
600
152
4
286
726
4
1313327
140
355
610
626
92
1343404 104
2642
17254382
28401118
1162946
1293277
3929957
234
594
4
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 FOUR MOUNTING SLOTS 75 (19) X 200 (508)4 TWO LIFTING SLOTS 100 (254) X 170 (432)5 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS6 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING7 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS15BQ72 DRS15BQ86
Specification Units 081502 TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 40 40 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 9648 384 Service Factor - 115 115 Max Blower Amps Amps (A) 14070 52 Locked Rotor Amps Amps (A) 630315 216 NEMA Starter Size - 43 3
Shipping Weight Lbs 923 923 Kg 4187 4187
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 59 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200 IWGbull Maximum ow 925 SCFM
bull Maximum vacuum 1347 IWGbull Standard motor 40 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Quiet operation within OSHA standards when properly piped or mued -
1 inlet muer included
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS15
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
40
80
120
160
200
240
0
100
200
300
400
500
600
0
50
100
0
50
100Temperature curves are based on standard model
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 60 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers Our environmental EN blowers are designed the same as the DR blowers except added features include
Heavy duty cast aluminum manifold Our spark resistant housing cover impeller muffler tower and manifold are
vacuum impregnated Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Explosion-proof motors standard and available in a variety of world voltages All metal-to-metal surfaces are sealed with RTV sealant
Various UL explosion-proof listings Consult factory
Environmental (EN) regenerative blowers are also available in our Chemical Processing (CP) configuration
Chem-ToughTM surface conversion corrsion resistant treatment for all castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less
Chemical duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
7741956
6131557
13753493
8622190
4651181
963
244
6
140
1
312793325
826
650
752 1651
1910
4131049
125
1
553
1 - 11 12 NPSCFEMALE THREADBOTH PORTS
1
ROTATIONDIRECTION
38 (96) DIA2X MTG HOLES
100
355
9
317
8
140
5
254
040
102
NOTES1 TERMINAL BOX CONNECTOR HOLE 75rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN101AG58L EN101AG91L CP101FN58LR CP101FN91LR
Specification Units 038171 038019 080622 038950
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 7437 9045 7437 9045 Locked Rotor Amps Amps (A) 63 1575 63 1575 Service Factor Amps (A) 3819 8945 3819 8945 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 47 47 47 47 Kg 213 213 213 213
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 25 IWGbull Maximum vacuum 23 IWGbull Standard motor 05 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN101
LegendPressureSuction
EN101
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 2Customer Service Fax +1 2152561338 wwwametekdfscomcom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
OUTIN
338 327
575
108
2
859 831
274
8
048
197
406
891
39450
1031
10(4) MTG HOLES
12043058
137
3485
7914
71
698
177
3
961
1090
397 DIA
1
122
2441
1001
2263
1 14 - 11 12 NPSCFEMALE THREADBOTH PORTS
146
12769
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREADgt2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN303AG58L EN303AG91L CP303FN58LR CP303FN91LR
Specification Units 038172 038026 080247 038954
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 9045 1575 9045 1575 Locked Rotor Amps Amps (A) 7236 16383 7236 16383 Service Factor Amps (A) 3819 89445 3819 89445 Starter Size - 000 0000 000 0000 Thermal Protection - 10 135 10 135 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 52 52 52 52 Kg 236 236 236 236
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP explosion-proof
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN303 EN303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor
628
375
492
666
512
893
159
5
112
1692
125
2268
130(4) MTG HOLES
L12
23
311
2
304762 953
11632954
119
718
182
4
2921
044
10132573
EN404AR72MLEN404AR58MLMODEL L (INMM)
1641416815503937
ROTATION DIRECTION
1
47 DIA
115 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN404AR58ML EN404AR72ML CP404FQ58MLR CP404FQ72MLR
Specification Units 038173 038174 080075 038958
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 10 10 10 10 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 208-230460 115230 208-230460 Max Blower Amps Amps (A) 114569 3216 114569 3216 Locked Rotor Amps Amps (A) 14472 3618 14472 3618 Service Factor Amps (A) 7236 202101 7236 202101 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 81 64 81 64 Kg 367 29 367 29
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor ATEX model certified
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 52 IWGbull Maximum vacuum 48 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN404
LegendPressureSuction
EN404
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
50
100
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
177
3
488
3175
120
7
698
125
475
4751206
107
4501143
327
831 452
(6) MTG HOLES
3327
178
192
042
135
3
1310
15
1367
2896
2616
538
114 REF
1030
343
7
18704750
1
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN454W58ML EN454W72ML CP454W72MLR CP454FR72MLR
Specification Units 080487 080488 080490 080494
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-CS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 115208-230 230460 230460 230460 Motor Nameplate Amps Amps (A) 1579-75 4623 4523 4623 Max Blower Amps Amps (A) 19109-95 5628 5628 5628 Locked Rotor Amps Amps (A) 96-48 3216 3216 3216 Service Factor - 10 0000 0000 0000 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 90 84 84 84 Kg 408 381 381 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 59 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN454 EN454
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN505AX58ML EN505AX72ML CP505FS58MLR CP505FS72MLR
Specification Units 038177 038178 080655 038962
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 20 20 20 Phase - Frequency - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Voltage AC 115230 230460 115230 230460 Motor Nameplate Amps Amps (A) 2211 5829 2211 5829 Max Blower Amps Amps (A) 2412 6432 2412 6432 Locked Rotor Amps Amps (A) 11256 5628 11256 5628 Service Factor - 10 00 10 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 92 84 92 84 Kg 417 381 417 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull Maximum vacuum 70 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN505AX72MLEN505AX58ML
LegendPressureSuction
EN505AX72MLEN505AX58ML
0
50
100
0
50
100
0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
OUTIN
442
112340
44
372 550
1364
1387
1397945
3465
(4) MTG HOLES
2248
822
35
569
475
128
1206
140
3251
05
127
1819
14213609
669170
553
15703988
159
2
3523
15
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN513W58L EN513W72L CP513FR58LR CP513FR72LR
Specification Units 038183 038037 038966
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115208-230 230460 115208-230 230460 Max Blower Amps Amps (A) 1579-75 4623 1579-75 4623 Inrush Amps Amps (A) 19497-90 5427 19497-90 5427 Service Factor Amps (A) 84-42 3216 84-42 3216 Starter Size - 10 0000 10 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 99 93 99 93 Kg 449 422 449 422
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 75 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN513 EN513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
OUTIN
5501397
(4) MTG HOLES
3609
571
1142
128
4751206
145
2901
3251
19194874
6561666
160
140
87 7
16556
1412
15683983
15
1421
575
146
10
5012
7
143
836
53
222
6058
6922
38
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN523M5L EN523M72L CP523FU5LR CP523FU72LR
Specification Units 038223 038184 TBD 038968
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 230 230460 Max Blower Amps Amps (A) 155-145 7437 155-145 7437 Locked Rotor Amps Amps (A) 181-167 84 181-167 84 Service Factor Amps (A) 94-88 6231 94-88 6231 Starter Size - 1 00 1 00 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D I-D I-D I-D
Shipping Weight Lbs 126 126 150 126 Kg 572 572 68 572
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN523 EN523
0
50
100
0
50
100
0
50
100
0
50
100
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
850
200
400
558
1638
598
800
1150
215
9
508
141
7
101
6
4161
1519
2032
2921
143(4) MTG HOLES
423
916
69
FEMALE THREADBOTH PORTS419
106416
222
825
209
6
7181824
7001778
L
16184110
7751969
095246
6371618
MODEL L (INMM)
562 DIA
2 - 11 12 NPSC
NOTE 1
2055207EN6F72L20845292EN6F5L
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD
POSITIONED AT 12 OrsquoCLOCK2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN6F5L EN6F72L EN6F86L CP6FW5LR CP6FW72LR
Specification Units 038361 038180 038438 TBD 038978
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 50 50 50 50 50 Phase - Frequency Voltage - Single-60 hz Three-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 575 230 230460 Max Blower Amps Amps (A) 195 147 57 195 147 Locked Rotor Amps Amps (A) 23 147 63 23 147 Service Factor Amps (A) 175 15276 38 175 15276 Starter Size - 2 10 0 2 10 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 190 167 167 190 167 Kg 862 757 757 862 757
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 85 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
Muffler included (part 522948)
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN6F72LEN6F5L
LegendPressureSuction
EN6F72LEN6F5L
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
bull
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
103 262
A C
DIRECTION OF ROTATION
B
ROTA
TIO
N
1171 2974
20 51
322
818
10
59
269
0
IN OUT
622 98 (2X) 1580 610 249 154926611811
6763000 D
1841
2 - 11 12 NPSCFEMALE THREAD
1806 4676 BOTH PORTS
4587
IN MM 512
MTG HOLE 130
591
150 DETAIL
(4X) MODEL A B C DNOTES
1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD EN633 181 1894 167 173 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN EN833 182 1959 180 176
PartModel Number
CP633FY72LREN633BA72LM
081697Specification Units 081698
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1785 1785 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Lbs 288 288Shipping Weight Kg 1306 1306
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200195 IWGbull
bull Maximum vacuum 155155 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0
20 40 60 80 100 120 140 160 180 200 220
34 68 102 136 170 204 238 272 306 340
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
414
746
1542
696
538
1052
3917
176
818
95
STRAIGHT THDS2 NPSC
BOTH PORTS
136
7
(4X) MTGHOLES
19374920
151
738
25
551140
05915
1512
1826719
231
587
064
173 492
125
382512813254
114202901
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN656M5XL EN656M72XL EN656M86XL CP656FU72XLR
Specification Units 080060 080059 080058 080142
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 208-230 208-230460 575 208-230460 Motor Nameplate Amps Amps (A) 155-145 7437 30 7437 Max Blower Amps Amps (A) 17 105 41 105 Locked Rotor Amps Amps (A) 95-86 5427 216 5427 Service Factor - 1 00 0 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 142 117 117 117 Kg 644 531 531 531
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull
bull Maximum vacuum 73 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN656M72XLEN656M5XL
LegendPressureSuction
EN656M72XLEN656M5XL
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
15363901
233517
24
437
9
194
349
35
5931
950
604
2413
130033021534
445175
168
242
72
258
610
18
5731455
10332624
8502159
16644227
1000254
166
9
233
2
663
657
261
918
ROTATIONDIRECTIONOUT IN
2 12 NPSCFEMALE THREADSBOTH PORTS
1
75 X 200 SLOT19508(4) PLACES
INMM
PartModel Number
EN757FL5MWL CP757FX5MWLR
Specification Units 081333 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS CHEM XP-SS Horsepower - 55 55 Phase - Frequency - Single-60 hz Single-60 hz Voltage AC 230 230 Motor Nameplate Amps Amps (A) 217 217 Max Blower Amps Amps (A) 299 299 Locked Rotor Amps Amps (A) 155 155 Service Factor - 1 1 Starter Size - 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D I-D
Shipping Weight Lbs 158 158 Kg 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 21Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
0
0
0
20
40
60
80
100
120
0
50
100
0
50
100
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Legend Pressure Suction
EN757FL5WL
120 40 80 120 160 200 240 260 300 340 380 420
68 136 204 272 340 408 442 510 578 546 714
mba
r
0
50
100
150
200
250
300
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
R031
CL OF BLOWER79
19906316
505
657
261
166
966
3
ROTATIONDIRECTION
L
174
444
3
182
718
MODELEN757M72XLEN757F72XL
L (INMM)1972500921005334
15363886
284
20
508
559
142
715
181
6
16754255
923
234
4
16094087
IN OUT
088
5601422
5731461
10372634
15353899
2 12 NPSCFEMALE THREADSBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
IN
MODELPART NO
NAMEPLATEMOTOR
INMM
PartModel Number
EN757M72XL EN757M86XL EN757F72XL CP757FW72XLR CP757FU72XLR
Specification Units 081176 081177 081174 081180 081181
Motor Enclosure - Shaft - XP-CS XP-CS XP-CS CHEM XP-SS CHEM XP-SS Mtl Horsepower - 30 30 50 50 30 Voltage AC 208-230460 575 208-230460 208-230460 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three - 60 Hz Three-60 Hz Three - 60 Hz Insulation Class - B B B B B NEMA Rated Motor Amps Amps (A) 7236 30 147 147 7236 Service Factor - 10 10 10 10 10 Maximum Blower Amps Amps (A) 105 40 1575 1575 105 Locked Rotor Amps Amps (A) 5447 22 15276 15276 5427 Starter Size - 00 0 11 11 00
Shipping Weight Lbs 158 158 158 158 158 Kg 717 717 717 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN757F72XLEN757M72XL
LegendPressureSuction
EN757F72XLEN757M72XL
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 24Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options Sealed Regenerative Blower wExplosion-proof Motor
2335 103359311536 2624 573
101
825
86
168
242
72
918
233
2 6
57
261
663
166
9
3901
1
OUT
1455
IN ROTATION DIRECTION
2 12 NPSC FEMALE THREADS BOTH PORTS
850
194
349
35
172
443
79
950175 2159
NOTES 1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
604
2413
1300 33021534
445 IN
MM 75 X 200 SLOT 19508 (4) PLACES 1664
4227
1000 254
PartModel Number
EN757FL5MWL EN808FL5MWL CP757FX5MWLR CP808FX5MWLR
Specification Units 081333 081231 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 55 55 55 55 Phase - Frequency - Single-60 hz Single-60 hz Single-60 hz Single-60 hz Voltage AC 230 230 230 230 Motor Nameplate Amps Amps (A) 217 217 217 217 Max Blower Amps Amps (A) 299 299 299 299 Locked Rotor Amps Amps (A) 155 155 155 155 Service Factor - 1 1 1 1 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Class B - Pilot Class B - Pilot Class B - Pilot XP Motor Class - Group - Duty I-D Duty I-D Duty I-D Duty I-D
Lbs 158 338 158 338Shipping Weight Kg 717 1533 717 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
D 25USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom ____
____
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWG bull Maximum vacuum 75 IWG bull Standard motor 50 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
Temperature curves are based on standard model
Legend Pressure Suction
EN808FL5MWL
0
50
100
0 40 80 120 160 200 240 260 300 340 380 420
0 68 136 204 272 340 408 442 510 578 546 714
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 26Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
(8) MTG HOLES
IN OUT
692
850
738 355
1415
709
088
224
111
3
189
1
902
1801
358
909
282
7
480
3
1875
2159
35941758
143
23565984
211
253
7
8752223
8602174 125
318
6751715
117
429
87
185470
3749
15754001
1476
17434427
562 DIA
ROTATIONDIRECTION
FEMALE THREADBOTH PORTS
2 12 - 8 NPSC
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT CONDUIT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN808BA72MXL EN808BA86MXL CP808FY72MXLR
Specification Units 081229 081230 081234
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 75 75 75 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 Motor Nameplate Amps Amps (A) 18693 74 18693 Max Blower Amps Amps (A) 220110 81 220110 Locked Rotor Amps Amps (A) 12663 56 12663 Service Factor - 11 1 11 Starter Size - 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 287 287 287 Kg 1302 1302 1302
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 27Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 85 IWGbull Maximum vacuum 90 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN808 EN808
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 28Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
MTG HOLEDETAIL
(4X)
20 51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
103262
11712974
ROTA
TIO
N
IN OUT
266676
AC
D
B
18414676
105
9 26
90
1806 4587
EN633 181 1894 167 173
MODEL A B C D
EN833 182 1959 180 176
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN833BA72LM CP833FY72LRM
Specification Units 081712 081708
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1995 1995 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Shipping Weight Lbs 297 297 Kg 1347 1347
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 29Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant bull bull Maximum pressure 200195 IWG bull Maximum vacuum 155155 IWG bull Standard motor 75 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions
Inch
es o
fW
ater m
bar
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
60 Hz
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model 0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 30Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
189
5692
1300
817
105
0
218
1
245
675
1096
821
709
1548
1860
481
31758
622
3
554
0
207
526
67
1714
2085
2784
4724
3932
1801
3302
FEMALE THREADBOTH PORTS
191485
13533437
23345928
9462403
9502413
17510752731
MODEL EN858BA72WL
L (INMM)23656007
EN858BD72WL 26006604
L
ROTATION DIRECTION
2 12 NPSC
NOTE 1
OUT IN
445
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN858BD72WL EN858BD86WL EN858BA72WL CP858FZ72WLR
Specification Units 038744 038745 080070 038980
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 100 100 75 100 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 2412 96 18693 2412 Max Blower Amps Amps (A) 3015 116 2613 3015 Locked Rotor Amps Amps (A) 234117 93 12663 234117 Service Factor - 21 1 11 21 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 338 338 326 338 Kg 1533 1533 1479 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 31Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN858D72WLEN858BA72WL
LegendPressureSuction
EN858D72WLEN858BA72WL
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 32Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
834
2118
IN OUT
EN909BG72WL - 038629
FEMALE THREADBOTH PORTS
9502413
24736281
723
185715994031
137348
259
657
9
202
5
15503698
300643
913
231
9
105
266
7
388 11
1
852159
1075
2731
846
21491163520
9062758
MODEL EN909BG72WL
L(INMM)30177663
EN909DB72WL 23666010
L
ROTATION DIRECTION
4 - 8 NPSC
(4) PLACES75 X 200 SLOT
SEE NOTE1
514
4
INMM
PartModel Number
EN909BG72WL EN909BG86WL EN909BD72WL CP909GA72WLR
Specification Units 081741 081736 081743 038982
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 15 15 10 15 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 3618 144 2412 3618 Max Blower Amps Amps (A) 4824 18 3216 4824 Locked Rotor Amps Amps (A) 240120 100 234117 240120 Service Factor - 22 2 21 22 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 524 524 504 524 Kg 2377 2377 2286 2377
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 33Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN909BG72WLEN909BD72WL
LegendPressureSuction
EN909BG72WLEN909BD72WL
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
50
100
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
0
50
100Temperature curves are based on standard model Temperature curves are based on standard model
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 34Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
ROTATIONDIRECTION
4 NPSCPORTS
150 DIA (381)LIFTING LUG
1
9002286
31257938
11382891
5691145
9752477
19254890
8752223 1111
2822
13063317
10372634
25
3264
31
217
755
30
122
531
12
24
762
7
200508
191485
07
619
3NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN979BK72WL EN979BK86WL CP979GB72WLR
Specification Units 080724 082277 081778
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 20 20 20 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 575 230460 Max Blower Amps Amps (A) 4623 184 4623 Locked Rotor Amps Amps (A) 6030 24 6030 Service Factor Amps (A) 334167 118 334167 Starter Size - 32 2 32 Thermal Protection - 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 533 533 533 Kg 2418 2418 2418
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 35Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 90 IWGbull Maximum vacuum 90 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
EN979
LegendPressureSuction
EN979
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 36Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
117
297
4
309
678
638
110027940
16994316426032
1025
3007612
233259239
96424486
44619
OUT IN
1757
96524503
127632410
327
15
243
617
22
86121869
301476556
L
143236373
128
8 153238913
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
INMM
MODEL LENGTH (INMM)EN14BK72MWL 32128159EN14DX72MWL 311857921
PartModel Number
EN14BK72MWL EN14DX72MWL EN14DX86MWL CP14GB72MWLR CP14GC72MWLR
Specification Units 081485 081486 081487 TBD 081491
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 30 30 20 30 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 200-230460 575 230460 200-230460 Max Blower Amps Amps (A) 4623 75-6633 265 4623 75-6633 Locked Rotor Amps Amps (A) 6030 8241 33 6030 8241 Service Factor Amps (A) 294147 448224 226 294147 448224 Starter Size - 32 33 3 32 33 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 601 737 737 601 737 Kg 2726 3343 3343 2726 3343
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 37Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 144 IWGbull
bull Maximum vacuum 115 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 38Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motor-less) Blowers AMETEK Technical amp Industrial Productsrsquo ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial (_RD) Remote Drive Blowers are motorless models built with DRENCPSL blower features and include
Rugged cast-iron arbor and bearing suspension system Oversized shaft to withstand heavy-duty side loads Precision balanced impellers for low vibration operation High speed versions built with heat treated impellers available
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
MF573RD
NOTES1 CONTACT FACTORY FOR PULLEY OPTIONS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
AIR OUT
ROTATION
AIR IN
C
E
B
A
F
D G
Specification INMM
Model Number Part Number A B C D E F G
MF573RD 026940 363 125 658 175 175 175 356 922 318 1671 445 445 445 904
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
10000 RPM
12000 RPM
14000 RPM
10000 RPM12000 RPM
14000 RPM
10000 RPM
12000 RPM14000 RPM
14000 RPM
10000 RPM
12000 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph
0
4
8
Do not exceed maximum speed shown on each graph
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
SL2RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
ROTATION
FLAT
14-20 UNC - 2B X 444 HOLES EQ SPACED ON 443 DIA
N
B
J
K
E
G
F
T
D
C
H
A
PS
Q
L
4 MTG HOLES
4 MTG HOLES(SAME AS OPPOSITE SIDE)
IN OUT
R
Specification INMM
Model Number Part Number A B C D E F G H J K L M N P Q R S T
SL2RD 026125 733 588 992 145 100 500 175 25 175 141 262 175 496 331 300 992 473 100 1862 1494 252 368 254 127 445 64 445 358 665 445 126 841 762 252 12 254
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
AIR AT 1
00˚C
25˚C50˚C75˚C
6000 RPM5500 RPM
5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
6000 RPM5500 RPM
5000 RPM4500 RPM
4000 RPM3500 RPM3000 RPM2500 RPM
6000 RPM5500 RPM5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
25˚C50˚C75˚C
AIR AT 100˚C
6000 RPM5500 RPM
5000 RPM4500 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph or 100degC
0
10
20
Do not exceed maximum speed shown on each graph or 100degC
0
10
2015
05
05
15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 404RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR404RDNT 036439 560 115 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 1422 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
EN404RDML 038334 1276 1150 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 3241 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
75˚CAIR AT 100˚C
50˚C
25˚C
2500 RPM
1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM
25˚C 6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
55004500350025001750
65006500
55004500350025001750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Do not exceed maximum speed shown on each graph or 100degC
01
08
70
Do not exceed maximum speed shown on each graph or 100degC
20
04
40
01
08
70
20
04
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 505RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR505RDNT 036437 568 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 1443 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
EN505RDML 038336 1458 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 3703 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000550045003500
2500
1750
75˚C
AIR AT 100˚C
50˚C
25˚C
2500 RPM1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM25˚C
6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
60005500
450035002500
1750
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC
15
20
10
Do not exceed maximum speed shown on each graph or 100degC
40
08 04
15
20
1040
08 04
Air Flow Rate - SCFM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 513RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR513RDNT 038076 607 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 1542 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
EN513RDL 038341 1190 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 3023 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM
2500 RPM
100˚C75˚C
50˚C
25˚C
60005500
450035002500
60005500
450035002500
2500 RPM
6000 RPM
5500 RPM
3500 RPM
100˚C75˚C
50˚C
25˚C
4500 RPM
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
4
8
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 523RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR523RDNT 037223 796 138 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 2022 3505 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
EN523RDL 038342 138 1555 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 3505 395 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
25˚C
AIR AT 50˚C
45003500250017505500
6000
5500 RPM6000 RPM
25˚C4500 RPM
3500 RPM2500 RPM
1750 RPM
5500 RPM6000 RPM
4500350025001750
55006000
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 230 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 229 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
8
16
0
8
16
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 6Customer Service Fax +1 2152561338 wwwametekdfscom
Dual muers provided in place of muer tower
____
Remote Drive (Motorless) Blowers
DRENCP 6RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR6RDNT 036185 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
EN6RDL 038343 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM1750 RPM
AIR AT 100˚C
50˚C
25˚C
55004500350025001750
2500 RPM 1750 RPM
2500 RPM
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
550045003500
25001750
75˚C
25˚C
50˚C
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 656RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR656RDNT 080610 735 1244 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 1867 3160 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
EN656RDL 080061 1512 146 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 385 3708 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM1750 RPM
100˚C
50˚C
25˚C
600055004500
350025001750
2500 RPM
1750 RPM
2500 RPM
6000 RPM
5500 RPM
4500 RPM
3500 RPM
100˚C
50˚C
600055004500
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
15
30
0
15
30
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 8Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motorless) Blowers
DRENCP 757RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR757RDNT 081847 667 1506 1725 362 25 100 175 505 450 619 644 250 922 640 450 1611 1694 3825 4382 919 64 254 445 128 1143 1572 1636 635 2342 1626 1143 4092
EN757RDML 081848 1506 2023 1725 362 25 100 175 450 505 619 644 250 922 640 450 1611 3825 5138 4382 919 64 254 445 1143 128 1572 1636 635 2342 1626 1143 4092
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
50˚C
5500
450035002500
2500 RPM2500 RPM
5500 RPM
4500 RPM
3500 RPM
5500450035002500
75˚C
50˚C
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
AIR AT 100˚C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 858RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR858RDNT 036413 851 1930 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 2162 4902 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
EN858RDL 038746 1930 2222 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 4902 5644 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4000 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4000
350025001750
75˚C
50˚C25˚C
AIR AT 100˚C
25˚C
4000 RPM
3500 RPM
2500 RPM1750 RPM
4000
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 909RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR909RDNT 081962 853 228 2322 350 500 1375 200 765 500 970 834 301 1297 902 500 198 2167 581 5898 889 127 349 508 194 127 2464 2118 765 3294 2291 127 5029
EN909RDL 081742 228 2451 2322 350 500 1375 200 765 500 970 834 400 1297 902 500 198
5791 6226 5898 889 127 349 508 194 127 2464 2118 1016 3294 2291 127 5029
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4500350025001750
75˚C
50˚C
AIR AT 100˚C
4500 RPM
3500 RPM2500 RPM1750 RPM
4500350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 979RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR979RDNT 080760 105 235 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 2667 5969 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
EN979RDL 080761 235 2517 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 5969 6393 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
3700
350025001750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM2500 RPM
1750 RPM
37003500
25001750
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 1233RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 FILTER 515256 1PIECE
ROTATION
J +- 12
A
Q +- 12E
G +- 25
D
SEEDETAIL AA
DETAIL AA
C +- 06
236599
03910
B
(4X) F
(4X) R
(2X) H
(2X) T
OUTINK +- 12
L +- 12
M +- 25
N +- 25
(2X) PNPSC THD
Specification
Model Number Part Number A B C D E F G J H K L M N P Q R T
DR1233RD 081853 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 669 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 1699 236 348
EN1233RDL 081854 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 689 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 175 236 348
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3500 RPM
2850 RPM
AIR AT 100˚C
50˚C4000 RPM
4300 RPM
40003500
2850
4500400035002850
4300
3500 RPM
2850 RPM
4000 RPM
4500 RPM
75˚C
AIR AT 100˚C
50˚C
75˚C
80 120 160 200 240 280 320 360 400 440 480 520
136 204 272 340 406 476 544 612 680 748 846 884
0
50
100
150
200
250
300
0
100
199
298
398
498
598
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
5
15
25
5
15
25
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS E 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 14RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR14RDNT 081475 987 2224 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 2507 5649 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
EN14RDL 081488 2224 3014 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 5649 7656 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
370035002500
1750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM
2500 RPM1750 RPM
3700
350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
30
60
0
30
60
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 14Customer Service Fax +1 2152561338 wwwametekdfscom
Application Specific Regenerative Blowers Specialty blowers for Commercial Spa High Temperature Natural Gas and Gasoline Vapor Recovery applications
Our industrial NC (NautilairTM Centraxial) blowers include Fiberglass or aluminum housing Aluminum impellers Permanently sealed bearings for 50000 hours life
Our instrument grade and variable flow SE (MinispiralTM Regenerative) blowers include AC and DC versions available for world voltages and maximum flow variability Glass filled molded phenolic impeller aluminum and phenolic case 30000 hour bearing life Small size and lightweight construction
Quiet to NC-47 office equipment standards
Our instrument grade SL (Spiral Regenerative) blowers include Rugged diecast aluminum housing endbells and impellers
Compact size with encased muffler for maximum noise reduction Low amp draw with highly efficient motor
Permanently sealed bearings for 40000 hours life Hermetically sealed models designed for glovebox use
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
111
8032
180 REF
813
4572
44
REF
TYP
411 DIA1044165
4191
Oslash224 DIA
569
210
533
4
416
REF
105
66
212 DIA
1
2
OUT
IN
INMM
PartModel Number
SE2B21 SE62B21 SE2B21A
Specification Units 081901 037395 080694
Phase - Frequency - Single-5060 Hz - Single-5060 Hz Voltage AC 110115 24 110115 RPM RPM 28503400 28503400 28503400 Insulation Class - B B B Full - Load Amps Amps (A) 1714 - 1714 Locked Rotor Amps Amps (A) 1715 - 1715
Shipping Weight Lbs 19 19 19 Kg 09 09 09
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
2 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L mdashdb
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Maximum vacuum 35 IWGbull Maximum ambient 40degC
bull Shaded pole motor with ball bearings
bull B10 bearing life 30000 hoursbull Weight 11 lb (05 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONSbull Sealed unitsbull International voltage and frequency (Hz)
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
LegendPressureSuction
Minispiral
LegendPressureSuction
Minispiral
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
2 leads 20 gaTFE coveredUL style 1180 (12 long stripped 50)
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
44
REF
TYP
111
8
032813
180 REF4572
411 DIA1044
1654191
Oslash224 DIA
569
210
533
4
416
REF
10
566
212 DIA
2
OUT
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12V21 SE24V21
Specification Units 037433 037434
Voltage Range VDC 9-15 24-32 RPM RPM 3600-6000 5500-6800 Insulation Class - B B Full - Load Amps Amps (A) 050-10 06-09
Weight Lbs 086 086 Kg 04 04
WARNING ndash ON MDC MODELEXCEEDING 10 AMP MAY DAMAGE CIRCUIT BOARD
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 70103 IWG (1532 volts)bull Maximum vacuum 70103 IWG (1532 volts)bull Maximum ambient 40degC
amp impellerbull Shaded pole motor with ball bearings
bull B10 bearing life 20000 - 30000 hoursbull Weight 086 lbs (039 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed control
Blower Performance at Standard Conditions12 V-MDC 24 V-MDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
15 V-MDC
12 V-MDC
9 V-MDC
32 V-MDC
26 V-MDC
24 V-MDC
LegendPressureSuction
Minispiral MDC
LegendPressureSuction
Minispiral MDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
BOTH PORTS
057
OD
145
114290
199505
217
552
226
574
116295
02564063
160
092234
054137
083211 0
75 O
D19
1
Oslash1
8346
5
119302
282716
066168
350889
421
106
9
Oslash 4201067
211
536
186
472
057
145
044
112
165419
067170
4071034
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 12
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21 SE24RE21
Specification Units 081548 080847
Voltage Range VDC 75-15 24-32 RPM RPM 4400-8750 4400-8750 Insulation Class - B B Full - Load Amps Amps (A) 12-25 12-16
Weight Lbs 10 10 Kg 05 05
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L db
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull 12 VDC operation 75-15 VDCbull 24 VDC operation 15-32 VDC
bull Maximum pressure 207 IWG (15)bull Maximum vacuum 207 IWG (15)bull Maximum ambient 40degC
amp impellerbull Brushless DC motor with integrated control electronics
bull Stainless steel ball bearings permanently lubricated for B10 bearing life 20000 - 30000 hours
bull Weight 19 lbs (086 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull International voltage and frequency (Hz)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
220 17 34 51 68 85 102 119 136 153
0 1 2 3 4 5 6 7 8 9
20
18
16
14
12
10
8
6
4
2
55
50
45
40
35
30
25
20
15
10
5
15 V-HDC
12 V-HDC
9 V-HDC75 V-HDCLOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
BOTH PORTS
056
ID14
2
106269
192488
217
552
224
569
130330
02564063
160
092234
053135
080203 0
75 O
D19
1 T
YP
Oslash1
750
444
119302
272691
066168
350889
416
REF
10
69
Oslash 4111044
210
5331
8547
00
5614
20
4210
7 R
EF
T
YP
165419
067170
4061031
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 14
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21A
Specification Units 081881
RPM RPM 7397 - 13205 Voltage Range VDC 75 - 15 Insulation Class - B Full - Load Amps Amps (A) 27 - 62
Weight Lbs 25 Kg 11
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOU
ND
PO
WER
LEV
EL
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
EQU
IVA
LEN
T SO
UN
D P
RES
SUR
E LE
VEL
db (r
e 0
0002
mic
roba
r)3
FEET
(09
1 M
ETER
S) F
RO
M N
OIS
E SO
UR
CE
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 26 IWG (15)bull Maximum vacuum 26 IWG (15)bull Maximum ambient 40degC
bull Brushless DC motor with integrated control electronicsbull Stainless steel ball bearings permanently lubricated for B10 bearing life
20000 - 30000 hoursbull Weight 19 lbs (086 kg)bull Compact high performance design 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull Speed sensing output (FPS)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
24
260 17 34 51 68 85 102 119 136 153 170 187 204 221
0 1 2 3 4 5 6 7 8 9 10 11 12 13
22
20
18
16
14
12
10
8
6
4
2
0
50
55
60
65
45
40
35
30
25
20
15
10
5
0
15 V-HDC
12 V-HDC
75 V-HDC
LOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
OUT IN
841
666
412
104
7
445
734
742142
175
OD
331
162
412
587
292
289
3091
1991
100
120 175
254
305 445
1217
300 TYP762
784
1491
25 -20 UNC -2B X 31 DEEP(4 MOUNTING HOLES EACH END)
997
498
263
160
ID
253
2
126
2
406
229582
OPTIONAL OUTLET TRIMMER
OPTIONAL INLET TRIMMER
12 CONDUIT HOLE (1) EACH END
56
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL2P2 SL2P52 SL2P90
Specification Units 036000 036013 036018
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 5 5 5 Voltage AC 115 208-230 380460 Phase - Frequency - Single-5060 Hz Single 60 Hz Three-5060 Hz Insulation Class - B B B Full - Load Amps Amps (A) 245360 95154 3441 Service Factor - 10 10 10 Locked Rotor Amps NEMA Amps (A) 100 43 19 Starter Size - 0000 0000 0000
Shipping Weight Lbs 27 27 27 Kg 122 122 122
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum vacuum 313 IWGbull Standard motor 05 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL2 Spiral SL2
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
656 MAX1666
7211831
12rdquo CONDUIT HOLE(1) EACH END
IN
OUT
1524600
130
3 M
AX
331
997
253
2
300 TYP762
924
5761463
2347
412
104
7
412
162
138351
292
287729
317805
25-20 UNC-2B X 31 DEEP(6) MOUNTING HOLES EACH END742
160
ID
175
OD
445
406
666
262
989
DIA
251
2
456 MAX1158
CAPACITORS ON SINGLEPHASE MODELS ONLY
PartModel Number
SL4P2 SL4P52
Specification Units 036009 036027
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 370380 229220 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 60 IWGbull Maximum vacuum 558 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL4 Spiral SL4
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
IN
OUT
762
1831
331
805729
742351
412
666
PHASE MODELS ONLY
(6) MOUNTING HOLES EACH END
(1) EACH END
6001524
1666656 MAX
721
130
3 M
AX
300 TYP
412 162
175
OD
138 292
287 317
104
7
445
456 MAX1158
262997
253
2
9242347
5761463
160
ID
40
6
989
DIA
25
12
CAPACITORS ON SINGLE
25-20 UNC-2B X 31 DEEP
12 CONDUIT HOLE
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL5P2 SL5P52
Specification Units 036010 036261
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 458675 185255 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 31 IWGbull Maximum vacuum 313 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL5 Spiral SL5
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
0
15
30
45
60
75
90
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
0
15
30
45
60
75
90
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
AB
B
CX
W
R S
L
F
PU
M N O11
3 (2
869
6)
J
(4X) MTG HOLES028 DIA
KG
VZ
T
250 (6350)AA
Oslash40HOLE (4X)
175 (4445)35 (8890)
TEFC MODEL
D (R
EF)
538
(136
65)
E
Y
Oslash5
19 (1
318
3)
495 (1257)
495 (1257)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
CX
W
Oslash769 (19528)
R S
L
P (DIA INLET)F
U
M N O
J
(4X) MTG HOLES028 DIA
KG
VZ
H (TYP)
T253 (6431)
HOLES FOR ELECTRICAL CONNECTIONS
14-20 UNC-2B X 50 DP(4) MTG HOLES EQUALLYSPACED ON A 3625 DIA BC
14-20 UNC-2B X 50 DP(4) MTG HOLES
175 (4445)350 (8890)
STANDARD MODEL
D3
49 (8
875
)
123
(31
35)
E
Y
150 (3810)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
R
S
T
U
V
W
X
Y
Z
AA
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
197(50)
278(706)
726(1844)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
NC33AG58(XP)
NC33AE9(TEFC)
NC33A(STD)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
420(1067)
278(706)
1394(3541)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
352(894)
278(706)
1335(3391)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)713
(1811)
PartModel Number
NC33A2G NC33A3G NC33A33G NC33AE9 NC33AG58
Specification Units 037791 037792 037793 080114 080113
Phase - Frequency - Single-5060 Hz Single-5060 Hz Three-5060 Hz Single-5060 Hz Single-5060 Hz Voltage AC 115 220230 208-230 115230 115230 RPM on 5060 Hz - 29003500 29003500 29003500 29003500 29003500 Insulation Class - B B B F F Full - Load Amps Amps (A) 344384 147182 110118 6030 44 Locked Rotor Amps Amps (A) 825 40 50 21105 3819
Shipping Weight Lbs 18 18 18 28 30 Kg 82 82 82 127 136
Motor Enclosure - Standard Standard Standard TEFC XP
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
80
70
60
50
40
90
80
70
60
50
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
SOUN
D PO
WER
LEVE
L ndashdb
(re
10
Wat
ts)
2075
75150
150300
300600
6001200
12002400
24004800
480010000
OCTAVE BAND CENTER FREQUENCY Hz
-12
NC33
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Thermoset plastic blower housing with aluminum impellerbull Permanently seal ball bearings in motor - L10 bearing life 50000 hoursbull Quiet operation within OSHA standardsbull Shipping weight 18 lbs (82 kg) for standard model
28 lbs (127 kg) for TEFC model30 lbs (136 kg) for XP model
bull Designed for UL and CSAbull Automatic thermal overload protection on standard motor enclosures
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
LegendPressureSuction
LegendPressureSuction
NC33 NC33
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
G650
165
1
B
C
E042107
1021259
LF
I HA
J
D
(4) MTGHOLES
THREAD
THREAD
MODEL
DR404AQ58M
DR454V58
DR505AW58M
DR513V58
DR656K58X
A (INMM) B (INMM) C (INMM) D (INMM) E (INMM) F (INMM) G (INMM) H (INMM) I (INMM) J (INMM) K (INMM) L (INMM)
8932268 1012257
4751207
4751207 192488 6281595 1152921 12163089 30762 375953 12883722 5915 12913279
225572 7461895 15423917 15173853 4141052 551397 15123841 5915 15513939
4751207
10302616 11382891 192488 6981773 12553188 325826 4501143 10812746 5915 1445367
10302616 11702972 187475 7261844 13533437
13523434
14383653 356927 4501143 14383653 5915 150381
114229014751207 223566 8692207 14213609 1584013 372945 5501397 1374349 5915 14583703
492125 11422901 1283251
1303302
12-14 NPSM
T-BOX
GND LUG
P DIA
2- NPSC
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY
FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL
LENGTHS NOT SHOWN
INMM
PartModel Number
DR404AQ58M DR454V58M DR505AW58M DR513V58 DR656K58X
Specification Units 037778 080485 037935 038143 080603
Motor Enclosure - Shaft Mtl - SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS TEFC-CS Horsepower - 10 15 20 15 30 Voltage AC 115230 115230 115230 115230 115230 Phase - Frequency - Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 1575 15276 21105 15276 31155 Service Factor - 14 13 12 13 10 Maximum Blower Amps Amps (A) 84 1785 2613 1785 278139 Locked Rotor Amps Amps (A) 3216 8543 13668 8543 200100 Recommended NEMA Starter Size- 000 10 10 10 151
Shipping Weight Lbs 64 76 83 90 51 Kg 29 345 376 408 231
Recommended Number of Jets - 3-6 5-10 5-10 12-17 8-12
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
Notes- The blower should not be stoppedstarted more than four times an hour - Use of relief valve 515092 is required for all blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 56 58 74 69 or 88 IWGbull Standard motor 10 15 20 30 HP Spa Duty ODP
(threaded)bull
Class B rated thermal protectionbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull Variable frequency drive package
UL amp CSA approved motor with permanently sealed ball bearings and
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
DR404DR454DR505DR513DR656
LegendPressureSuction
DR404DR454DR505DR513DR656
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
100
200
0
100
200
0
100
200
0
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
PartModel Number
DR10RDNT SS10RDNT HS10RDNT
Specification Units 036594
Shaft Material - Carbon Steel Stainless Steel Hastelloy Speed Range - 1750-4500 1750-4500 1750-4500 Housing Cover Cover - Cast Iron Stainless Steel Hastelloy
Shipping Weight Lbs 400 500 600 Kg 1814 2268 2722
SS = Stainless Steel HS = Hastelloy
1 DR10RDNT not recommended for use with explosive gas due to material of construction
2
3
4
Maximum operating temperature Blower outlet air temperature should not exceed 260degC (air temperature rise plus inlet temperature)Contact factory for use above 260degC blower outlet air temperature
AMETEK will not be liable for blowers operated beyond factory specic RPM
All applications must be reviewed Contact application engineering for assistance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
bull Packaged on baseplate with V-belts or coupling guard amp motorbull High temperature Vitonreg sealsbull Krytoxreg grease high temperature bearings
PACKAGEMOTOR OPTIONSbull International voltage amp frequency (Hz)
bull Packing gland or double faced seal options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Variable frequency drive package
Note For accessories special high temperature models may be required
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
20
40
0
20
40
AIR T 100 ordmC
75 ordmC
50 ordmC
4500 RPM3500 RPM2500 RPM
1750 RPM
4500
3500
25001750
AIR T 100 ordm C
75 ordm C
50 ordm C
4500 RPM3500 RPM
2500 RPM
1750 RPM
4500
3500
25001750
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
Rev 204
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
MD101CB4 MODEL SHOWNTEFC MOTOR
MD101CC4 MODEL SHOWNXP MOTOR
Oslash9
8424
99
249
9
188478
478
169429
429
4121047
1047
1500381
6001524
1524
RESET BUTTONOslash 87 CONDUIT HOLE
22
350889
889
300
762
762
262
665
665
OUTLET INLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE71
71
Oslash9
84
188
169
8252096
412
1664216
600
LEADS FAR SIDE
350
300
262
OUTLETINLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE
75-14 NPT
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
ROTATION
ROTATION
PartModel Number
MD101CB4 MD101CC4
Specification Units 038014 038271
Motor Enclosure - Shaft Mtl - TEFC Explosion-proof Horsepower - 25 25 Phase - Frequency Voltage - Single-60 hz Single-60 hz Motor Nameplate Amps AC 115 115 Max Blower Amps Amps (A) 26 26 Locked Rotor Amps Amps (A) 22 22 Service Factor Amps (A) 64 72 Starter Size - 10 10 Thermal Protection - 00 00 XP Motor Class - Group - Class B - Automatic Manual Reset Class B - Automatic
- - I-D
Shipping Weight Lbs 40 40 Kg 181 181
F 21
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
FEATURESbull Hermetically designed seal-less blowerbull Continuous operationbull Manufactured in the USA
bull Maximum pressure 28 IWGbull Maximum vacuum 265 IWGbull Standard motor 025 HP TEFC or XPbull Disconnect motor without disassembling from piping
bull Permanently sealed ball bearings in housing and motorbull Quiet operation within OSHA standards
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
AIRSG = 10
NATURAL GASSG = 056
NATURAL GASSG = 056
AIRSG = 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 GVR313AK4H MODELS SHOWN
10502667
ROTA
TIO
N
375
953
14193604
113
8 (T
YP)
289
1
1 12 NPTF (2) PLACES (GVR313)
22559
4001016
IN OUT
68751746
421067
348688
224 49
124
5
65
165
1
BOTTOM VIEW
INMM
PartModel Number
GVR313AK4H GVR313AK58H GVR313AK72HA GVR313AK91H GVR313AE4HA
Specification Units 038584 081531 081470 081524 080274
Motor Enclosure - Shaft Mtl - Explosion-proof - CS Explosion proof - CS Explosion proof - CS ATEX - CS TEFC Horsepower - 05 05 05 075 05 Phase - Frequency Voltage - Single-60 hz Single-5060 Hz Three-60 Hz Three-50 Hz Single-60 Hz Motor Nameplate Amps AC 115 110220 230460 400 115 Max Blower Amps Amps (A) 94 8442 1407 14 74 Locked Rotor Amps Amps (A) 76 6834 1407 11 74 Service Factor Amps (A) 45 45 10251 9 47 Starter Size - 10 10 115 10 10 Thermal Protection - 0 0 00 0 0 XP Motor Class - Group - Class B - Automatic Class B - Automatic Class B - Automatic Thermistors Class B - Automatic
- I-D 1-D 1-D EExd IIB 1-D
Shipping Weight Lbs 39 39 39 45 39 Kg 177 177 177 204 177
1 115 voltage 1 phase motors are standard 230 volt motors available As an option a transformer could be used2 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors
or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
Rev 204
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
FEATURESbull Manufactured in the USA
bull Maximum pressure 45 IWG bull Maximum vacuum 408 IWGbull Standard motor 05 HP TEFCbull Anodized cast aluminum blower housing impeller amp cover
bull Quiet operation within OSHA standardbull ROHS gold irridite coatings on aluminum surfaces
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONS
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
GVR313
GVR313
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 24Customer Service Fax +1 2152561338 wwwametekdfscom
Accessories AMETEK Dynamic Fluid Solutions ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our accessories for regenerative blowers inlude
Filtration Accessories Measurement Accessories Noise Reduction Accessories Valves and Gauges
VFD Drives Air Knives
Blower Model Reference Key A = SPIRAL E = DRENCP656 6 633 S7 B= DRENCP068 083 101 202 F = DRENCP 757 808 858 S9 P9 (Inlet Only) C= DRENCP303 312 313 353 G= DRENCP833 S13 P13 (Inlet Only) D = DRENCP404 454 513 505 555 523 H = DRENCP909 979 1233 14 S15 P15 (Inlet Only)
Blower Connection Key NPTndash American National Standard Taper Pipe Thread (Male) NPSCndashAmerican National Standard Straight Pipe Thread for Coupling (Female) SO ndash Slip On (Smooth ndash No Threads)
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inlet Filter (Single Connection)
Inlet Filters protect the blower and the air distributionsystem from dust and other airborne particles andcontaminants Normally used in pressure systems
A
Oslash
B
C Oslash
SPECIFICATIONS HOUSING ndash Steel MEDIA ndash Polyester EFFICIENCY ndash 97-98 (8 to 10 micron particle size) FILTER ELEMENT ndash Replaceable (see filter elements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particle size) available
PartModel Number
Specification Units 477411 516466 515122 515123 515124 515125 515145 515151 516511
Filter Element - A B C D E E F G H H Ref Blower Model - 271078 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 200 SO 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 456 600 600 775 1000 1000 1000 1000 1600 mm 1158 1524 1524 1969 254 254 254 254 4064
Dimension B Inches 612 650 650 725 1225 1250 1300 1400 1500 mm 1554 1651 1651 1842 3112 3175 3302 3556 381
Dimension C Inches 200 100 15 200 200 250 300 400 600 mm 508 254 381 508 508 635 762 1016 1524
Z Media Filter PN - 517865 517866 517867 517868 517869 517870 517871 517872
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 11258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inline Filter (Dual Connection)
Inline Filters protect the blower from harmful dustand other particles that may be drawn into theblower through the air distribution systemNormally used in vacuum systems
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron particle size)FILTER ELEMENT ndash Replaceable (see filterelements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particlesize) available Feature 14 threaded tap for gauge connection on inlet and outlet
Inline lter PN 271200 is a straight through designInlet is directly opposite of outlet
D DIA
B
A
C DIA
PartModel Number
Specification Units 271200 516461 515254 515255 515256 516463 516465 517611
Filter Element - 271078 516434 516434 516435 516435 515135 515135 516515 Ref Blower Model - A B C D E F G H H Inlet Connection - 175 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M Outlet Connection - 200 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M
Dimension A Inches 525 725 700 800 800 1400 1400 1800 mm 1334 1842 1778 2032 2032 3556 3556 4572
Dimension B Inches 831 650 650 1025 1025 2650 2700 2800 mm 2111 1651 1651 2604 2604 6731 6858 7112
Dimension C Inches 200 100 150 200 250 300 400 600 mm 508 254 381 508 635 762 1016 1524
Dimension D Inches 175 100 150 200 250 300 400 600 mm 445 254 381 508 635 762 1016 1524
Z Media Filter PN - 517886 517887 517888 517889 517890 517891 517892
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Silencers (Single Connection)
FilterSilencers reduce noise levels whileensuring clean air is provided to the blower andthe air distribution system Normally used inpressure applications
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron size)FILTER ELEMENT ndash Replaceable (see filter elements)
A
Oslash
B
C
Oslash
PartModel Number
Specification Units 516487 516489 516491 516493 516495 516497 516499 516513
Filter Element - B C D E E F G H H Ref Blower Model - 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 600 600 1000 1000 1000 1000 1233 1600 mm 1524 1524 254 254 254 254 313 4064
Dimension B Inches 650 650 725 1225 1250 1250 1387 1500 mm 1651 1651 1842 3112 3175 3175 352 381
Z Media Filter PN - 517878 517879 517880 517881 517882 517883 517884 517885
Dimension C Inches 100 150 200 200 250 300 400 600 mm 131541012 131541266 13154152 131541774 131542028 131542282 131542536 13154279
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 31258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Element
All ROTRON Air Filters and FilterSilencers have replaceable filter elements The filter media is polyester designed for high efficiency over a wide spectrum of industrial applications See yumllter element cross reference table Filter elements supplied with foam pre-filter
Standard Replacement Filter Element Cross Reference Table
271200 271078 515158 515134 516489 515132477411 271078 515254 516434 516491 515133515122 515132 515255 516435 516493 515134
515123 515133 515256 516435 516495 515134515124 515134 516461 516434 516497 515134515125 515134 516463 515135 516499 515135
515145 515134 516465 515135 516511 516515515151 515135 516466 515132 516513 516515515157 515133 516487 515132 517611 516515
HT
For DR Blower Models
OslashID
OslashOD
Filter Filter FilterElement Element Element
PartModel Number
Specification Units 515132 515133 515134 515135 516434 516435 516515
Z Media Filter PN - 517873 517874 517875 517876 517893 517894 517877
Dimension ID Inches 300 363 35 475 256 350 800 mm 762 922 889 1207 65 889 2032
Dimension OD Inches 438 588 588 788 500 588 1175 mm 1113 1494 1494 2002 127 1494 2985
Area SqFt 475 475 950 963 475 875 963 SqM 0 0 1 1 0 1 1
Dimension HT Inches 15 23 45 83 20 45 190 mm 381 584 1143 2108 508 1143 4826
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 41258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
By separating and containing entrained liquidsROTRONrsquoStrade moisture separator helps protect our regenerative blowers and the end treatment systemfrom corrosion and mineralization damage Recommended for all soil vacuum extraction Applications
applications
PLASTIC ldquoPrdquo DESIGN METAL ldquoDrdquo DESIGN METAL ldquoBrdquo DESIGN
SPECIFICATIONSSEPARATION METHOD ndash High Effciency Cyclonic RELIEF VALVE MATERIAL ndash Brass amp Stainless SteelFLOAT MATERIAL ndash CopperFLOAT SWITCH ndash SPDT Explosion-proof
NEMA 7amp9 5 Amp max
(OPTIONAL)
VALVE
(OPTIONAL)
ODINLET
(PLUGGED) SWITCH(OPTIONAL)
G
D
H
H
(PLUGGED)
C
J
B
34NPT
CAPACITY(PER CHART)
EF
390
(OPT
ION
AL
LOW
SW
ITCH
)
SWITCH(OPTIONAL)
INLET
H
B
DJ
E
F
(OPTIONAL)
(PLUGGED)
B
VALVE
(OPTIONAL)
J
D
C
E F
G
VALVE
34NPT
INLETOD
FLOAT SWITCH
34 NPT
VACUUM RELIEF
VACUUM GAUGE
14 NPT FLOAT LEVEL 14 NPT
DRAIN
WATER LEVEL
DRAIN - 1 NPT INTERNAL THD
FLOAT LEVEL
OD
VACUUM GAUGE
14 NPT
VACUUM RELIEF
VACUUM GAUGE
VACUUM RELIEF
DRAIN
TMMOISTURE SEPARATOR
RAP AT ORI SO T U R E
EM
S
A
A
INSTALL FLOAT SW
INFO PACKET
MOISTURE SEPARATOR
TM CYCLONICACTIONCAUTIONFREEZING MAY CAUSE DAMAGEMOISTURE SEPARATORS USED IN TEMPERATURES BELOW 32oslashF (0oslashC)MUST BE PROPERLY WINTERIZED
A
T ORURE
G
OUTLETOUTLET
OUTLET
PartModel Number
MS200PS MS300PS MS350BS MS500BS MS600BS MS1000BS
Specification Units 038519 038520 038357 080660 080659 038914
Dimension A Inches mm
238 605
288 732
325 826
325 826
400 1016
600 1524
CFM Max CFM m3hr
200 340
300 510
350 595
500 850
600 1020
1000 1700
Dimension B Inches mm
2246 5705
2246 5705
2800 7112
2800 7112
2700 6858
3100 7874
Dimension C Inches mm
1600 4064
1600 4064
2300 5842
2300 5842
2300 5842
2700 6858
Dimension D Inches mm
325 826
325 826
400 1016
400 1016
400 1016
400 1016
Dimension E Inches mm
3105 7887
3105 7887
3725 9462
3737 9492
3737 9492
4732 12019
Dimension F Inches mm
3330 8458
3330 8458
3950 10033
5450 13843
5450 13843
5170 13132
Dimension H Inches mm
6 1524
600 1524
975 2477
975 2477
925 235
1000 254
Dimension G Inches mm
450 OD 1143
450 D 1143
450 OD 1143
663 ID 1684
663 ID 1684
862 OD 2189
Dimension J Inches mm
1325 3366
1325 3366
1750 4445
1750 4445
1750 4445
1988 505
Drain Internal Thd - 34 34 1 1 1 1
Shipping Weight Lbs Kg
42 191
42 191
82 372
95 431
96 435
150 68
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
404
ForDRENCP
BlowerModel
SelectorMoistureSeparator
Model
Liquid-holdingCapacity(gallons)
Inlet(OD)
Outlet
MaxVacuum
Allow(IHG)
454
MS200PS 7 238 12
45 OD
MS300PS 7 288
MS350BS
MS500BS 40325
MS600BS 40663 ID 22
MS1000BS
Pre
ssur
e D
rop
(IWG
)
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
1
2
3
4
5
6
Flow Rate (SCFM)
65 60 862 OD
505513523555633833656
6757808
909
8581233
97914
The moisture separator shall be designed for use in a soil vapor extraction system capable of continuous operation with a pressure drop of less than six inches of water at the rated ow of _____ SCFM The separator shall be capable of operation under various inlet conditions randing from a ne mist to slugs of water with high eciency
The moisture separator shall incorporate cyclonic separation to remove entrained water The separator must protect against an overow by fail safe mechanical means An electrical switch or contact(s) alone is not an acceptable means of protection against overow but is a good backup
The body of the moisture separator shall be constructed of heavy wall plastic or heavy gauge cold rolled steel The steel interior and exterior shall be epoxy (powder) coated to resist abrasion corrosion and chipping that might expose the surface The inlet shall be tangentially located and welded to the body The outlet port shall be constructed of PVC or cast aluminum alloy anged and sealed to the center of the top of the separator The separator shall incorporate a non-sparking copper oat ball and an adjustable relief valve to protect against overow and overheating the blower
The moisture separator must have a liquid capacity of _____ gallons The inlet shall be _____ inch OD slip-on type The outlet shall be _____ inch OD slip-on type
20 Moisture SeparatorTM Specications
21 Duty
22 Principle of Operation
23 Construction
24 Capacity and Dimension
25 Pressure Drop
MS2
00PS
MS3
00PS
MS3
50BS
MS5
00BS
MS6
00BS
MS1000
BS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
FEATURESbull Direct reading in SCFMbull Low pressure drop (2-4 typical) across
the flow meterbull Non-clogging low impedance air streambull Light weight aluminumbull No moving partsbull Large easy-to-read dialbull Accurate within 2 at standard conditionsbull Good repeatabilitybull Available in 2 3 and 4 sizesbull Factory conyumlgured for quick installationbull 048 Allen key supplied for gauge adjustment
OPTIONSbull Corrosion-resistant version with Chem-Tough
trade or in stainless steelbull FDA-approved Food Toughtrade surface conversion
BENEFITS
bull OPTIMIZE SYSTEM EFFICIENCY Measuring the correct air ˜ow canassist you in yumlne-tuning to yoursystemrsquos optimal efficiency
bull BALANCE MULTI-PIPING SYSTEMSWhen evacuating CFM from more than onepipe di˝erent run lengths or end systemimpedance can cause one pipe to handlemore CFM than the other With an accurateCFM reading piping can be balanced bybleeding air inout or by creating an extraimpedance
bull DETECT CHANNELING OR PLUGGINGFor systems in which channeling orplugging can occur a change in the CFMmeasured can help indicate the unseenchanges in your system
PartModel Number
FM20C030Q FM20C045Q FM20C065Q FM20C125Q FM20C175Q FM20C225Q
Specification Units 550599 550600 550601 550602 550603 550604
Flow Rate CFM 6-30 9-45 13-65 25-125 35-175 45-225 m3hr 10-50 15-77 22-111 43-213 60-300 77-383
Threads B - 2-115 2-115 2-115 2-115 2-115 2-115
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
PartModel Number
FM30C250Q FM30C350Q FM30C475Q FM40C450Q FM40C600Q FM40C850Q
Specification Units 550605 550606 550607 550608 550609 550610
Flow Rate CFM 50-250 70-350 95-475 90-450 120-600 170-850 m3hr 85-425 119-595 162-808 153-795 204-1020 289-1445
Threads B - 3-8 3-8 3-8 4-8 4-8 4-8
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
HOW IT WORKSHIGH TEMPERATURE PRESSURE CORRECTION
TYPICAL FLOW METER ARRANGEMENT
ROTRONrsquoS ˜ flow meter is a venturi style designAfter air enters the inlet the pressure ismeasured in the P1 tap The second tap P2measures the pressure at the throat Thedifferential between P1 and P2 registers across a special calibrated CFM gauge to provideaccurate readings The throat is then expandedback to the original size to keep pressure loss tounder2-4 IWG
SCFM 1SCFM 2 =
147 x 530Pf2 Tf2 + 460radic( ) ( )
Pf 2 = Absolute Pressure inPSIA Tf2 = Temperature in degF
bull Use on inlet to limit need to correct for highpressure or elevated outlet temperature
bull Standard model limits = 140degF and 30 PSIG
TYPICAL GAUGE FACE
REGENERATIVE BLOWER GROUP
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
FLOW DIRECTION
375
375
20
287DIA
556
175
35REGENERATIVE BLOWER GROUP
C
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
B
OslashF
TMMOISTURE SEPARATOR
R A PATORIS OTURE
EM
S
BLOWER
INLET FLOWMETER SYSTEM UNDER VACUUM
SYSTEM PIPING
P RE S SUR E 3 0
P S I GXAM
014070
210 280
350
MINIHELIC II
AMETEKROTRON TIPTECHNICAL amp INDUSTRIAL PRODUCTS
IN OUT
P1 P2
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Digital Flowmeter
316
187
3583
3780
1 2 3 4
2596
275
48114
350 100
Oslash16 (2X)MOUNT HOLES
OUT
LOW
HIGH
-COM
+EXC
189 169
551
Remote air flow rate monitoring and system automation control can now be achieved through the use of 4-20 mA output signalsOur 4-20 mA analog outputs are proportional to system flow rates and can be used with PLC controlled operations to monitorsystem performance Those same outputs provide digital displays for direct readings in SCFM when paired with our LCD DigitalReadout option Combined with our Variable Frequency Drives you can now achieve a completely automated system capable ofadjusting blower performance to meet changing system demands Maintaining your system at peak performance gives yourcompany the competitive edge needed in todayrsquos marketplace
FM20S030Q FM20S045Q FM20S065Q FM20S125Q FM20S175Q FM20S225Q FM30S250Q FM30S350Q FM30S475Q FM40S450Q FM40S600Q FM40S850Q 550838 550839 550840 550841 550842 550843 550844 550845 550846 550847 550848 550849
LCD DISPLAYFM20L030Q FM20L045Q FM20L065Q FM20L125Q FM20L175Q FM20L225Q FM30L250Q FM30L350Q FM30L475Q FM40L450Q FM40L600Q FM40L850Q 550860 550861 550862 550863 550864 550865 550866 550867 550868 550869 550870 550871
DIFFERENTIAL PRESSURE TRANSMITTER 4-20 mA signal output control signals provide flow rate monitoring capabilities from remote locations NEMA 1R-raintight enclosure orotects the integrated DC power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter Weight 3 lbs Signal Output 4-20 mA DC1
HiLo pressure fittings feature snap lock action to unsure trouble-free connections2
System includes standard flowmeter for on-site readings and troubleshooting Operating temperature 0oF to 150oF Drawing available
LCD DIGITAL READOUT OPTIONS Factory configured to display direct readings in SCFM to a remote location up to 50 from signal output1 NEMA 4 IP65 enclosure ready for panel mount instlation power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter installation Power input 120 VAC 5060Hz AC Field configurable to 240VAC Display 5 digit 7 segment 5 high LED w33Hz update rate Operating temperature 10oC to 40oC Weight 1lb 14oz
Drawing available Note 1 4-20 mA output control wiring to be customer supplies Shielded 2 conductor cables 22 AWG is recommemeded for runs up to 100 For longer runs contact factory
Note 2 Use 516 OD stiff wall tubing-connect Lo on flowmeter to Lo on 4-20 mA enclosure Hi on flowmeter to Hi on 4-20 mA enclosure Tubing must be equal in length (Maximum length is 1o feet)
DIFFERENTIAL PRESSURE TRANSMITTER
USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 9Customer Service Fax +1 2152561338 wwwametekdfscom
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
____
Accessories
Noise Reduction - Sound Attenuating Enclosure
Frameless sound attenuating enclosures are a proven way to reduce regeenrative blower mechanical noise when additional mufflers are just not enough Additional enclosure options are available
FEATURESExcellent noise reduction (~10DbA)Resistance to elements and aesthetic appearanceCompact size for ease of installationEasy access for routine maintenance (removable foor and sidewalls)
SPECIFICATIONS Roof floor and walls galvanized 16 ga carbon steel sheet metal Louvers andor hood Riveted aluminum Hardware Chrome plated aluminum handles with stainless steel fastners Latches Over center glvanized with adjustable tension and padlock eye Sound attenuating material 2 rigid polyester foam with mylar facing (rated UL-94) Exterior finish Polyurethane enamel
3000
5000
4600
LIFTING HOLE(PLUGGED)TWO (2) PER SIDE(TOTAL 4)
950
950
END SECTION
END SECTION3100 CLEAR
1500
18 FANASSEMBLY
200 200
2600 CLEAR
Enclosure ventilation 13 HP 230460V 3-phase or 1-phase 5060Hz fan TEFC or XP motors Fan Guard Nickel plated wire type
PartModel Number
SAE30W72F SAE36W72F
Specification Units 552904 552905
Width Inches 30 36 mm 762 9144
Blower Size - 656 707 757 808 858 909 979 P9 S9 14 P13 S13 P15 S15
Height Inches 46 52 mm 11684 13208
Length Inches 50 60 mm 1270 1524
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - InletOutlet Muffler (Single Connection)
Muers lower blower noise in areas where reduced sound levels are required
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
D
C
B
A
PartModel Number
Specification Units 523627 523626 523625 523624 523623 523622
Ref Blower Model - B C D E E E Inlet Connection - 10 NPT Male 125 NPT Male 150 NPT Male 200 NPT Male 200 NPSC Female 200 NPT Male
Dimension A Inches 400 400 400 400 400 400 mm 1016 1016 1016 1016 1016 1016
Dimension B Inches 1093 1093 1093 1093 1093 1575 mm 2776 2776 2776 2776 2776 4001
Dimension C Inches 1398 1407 1457 1216 1243 1695 mm 3551 3574 3701 3089 3157 4305
Dimension D Inches 100 125 150 200 200 200 mm 254 318 381 508 508 508
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - Inline Muffler (Dual Connection)
Inline Muers are utilized for noise reduction inapplications where piping systems are connected directlyto both ends of the muer Muer may be used on inletor outlet of blower
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
C
B
A OUTLETCONNECTION
INLETCONNECTION
PartModel Number
Specification Units 550888 522948 529900 551377 515185 511569 515210 551565 516264
Ref Blower Model - D E E E F G G G H Inlet Connection - 15 NPT-M 20 NPT-M 20 NPSC-F 20 NPT-M 25 NPT-M 30 NPT-M 40 NPT-M 40 NPT-M 40 NPT-M Outlet Connection - 20 NPT-F 20 NPSC-F 20 NPSC-F 20 NPT-M 25 NPT-F 30 NPT-F 40 NPT-F 40 NPT-M 40 NPT-F
Dimension A Inches 400 400 438 400 612 700 1000 1000 800 mm 1016 1016 1113 1016 1554 1778 254 254 2032
Dimension B Inches 775 1575 1575 1575 1500 1800 2400 2400 2200 mm 1969 4001 4001 4001 381 4572 6096 6096 5588
Dimension C Inches 155 1845 1845 1815 1900 2225 3000 3000 2775 mm 3937 4686 4686 461 4826 5652 762 762 7049
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Relief Valve - Mechanical
Part Model Number
Specification Units 551026 551027 523230
Ref Blower Model - B C D D E F A B C D E F
Range in H2O mbar
20-180 498-4484
415-263 1034-6551
35-90 872-2242
Connection - 1 12 2 Description - Mechanical Mechanical
2 Mechanical Vacuum Only
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS G 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Pressure Regulating Diaphram Valve
PRESSURE RELIEF B is the system port and A is the vent or atmospheric port
VACUUM RELIEF A is the system port and B is the vent or atmospheric port For vacuum mode customer must remove snap ring and screen
NOTE Replace cap after adjusting setting Valve will not operate with cap removed Differential adjustment screw is under the cap
Fig 1 Fig 2
NOTE Blower Model P13 requires two 515093 relief valves
The PRD Valve is installed to prevent excessivesystem pressure or vacuum that could result fromline restrictions Valves should be installed at theblower outlet (downstream) in pressure systemsand at blower inlet (upstream) in vacuum systemsThese valves are suitable for air natural gaspropane and other non-corrosive service
Note PRD valves are not factory preset but areeasily field adjustable
SPECIFICATIONSVALVE BODY ndash Aluminum (1) CastIron (2) VALVE SPRING ndash SteelDIAPHRAGM ndash Nitrile
D
C
DIFFERENTIALADJUSTMENTSCREW
A
BGAUGEPORT
SEENOTE
GAUGEPORT
A
B
D
C
PartModel Number
Specification Units 515092 529612 529857 529858 551130 515093 529859 550246 550247
Range in H2O 27-125 110-415 277-554 7-18 14-62 48-194 110-277 97-197 97-194 mbar 673-3114 274-10338 690-1380 174-448 349-1544 1196-4833 274-690 2416-4907 2416-4833
Description - Fig 1 Fig 1 Fig 1 Fig 2 Fig 2 Fig 2 Fig 2 Pressure Vacuum Ref Blower Model - B C D E B C D E B C D E F G F G F G F G H H Inlet Connection - 1 1 1 2 2 2 2 25 25 Outlet Connection - 1 1 1 2 2 2 2 25 25
Dimension A Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension B Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension C Inches 412 412 412 712 712 712 712 619 619 mm 1046 1046 1046 1808 1808 1808 1808 1572 1572
Dimension D Inches 870 870 870 900 900 900 900 765 765 mm 221 221 221 2286 2286 2286 2286 1943 1943
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Gauges
ROTRON has a variety of gauges for pressurevacuum and temperature measurements invarious ranges These gauges are reliable andrugged
SPECIFICATIONS
Pressure Vacuum TemperatureCASE ndash Drawn Steel Finished CASE ndash Steel
LENS ndash GlassACCURACYndash 1
in Black EnamelDIAPHRAGM ndashBronze LENS ndash ClearPlastic ACCURACYndash2WEIGHT ndash 12 lbCONNECTION ndash 14NPT FACE ndash 2 12 dia
WEIGHT ndash 14 lbCONNECTION ndash 12NPT FACE ndash 3 Dial
Pressure Vacuum
Temperature
200
180
160
140
120100
80
60
40
20
100
50
150
200 250
350
400
300
degF
degC
10
0
1
2
3
4
5
6
PRESSURE
0
2040
60
80 100
120140
160
P S INCHE S OF WAT E RI
25 plusmn03Oslash 318 plusmn12
250 plusmn06
338 plusmn12
12 NPT CONNECTION
PartModel Number
Specification Units 551376 271949 529428 271950 551368
Range - Pressure Pressure Vacuum Vacuum Temperature Description - 0-60 IWG 0-160 IWG 0-60 IWG 0-160 IWG 0-200 Deg C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Variable Frequency Drive
A Variable Frequency Drive (VFD) is an adjustable speed AC motor control designed to speed the blower RPM up or down Our VFDs are designed to minimize losses and deliver increased efficiency low maintenance and the long life expected from the ROTRON product line
FEATURESbull
ncy by controlling motor RPMsbull Accepts 3Oslash or 1Oslash inputs to drive 3Oslash motor blower
assembliesbull Accepts 4-20 mA 0-5 VDC or 0-10 VDC inputs forsystem automation control and intregation
bull Provides dynamic breaking capabilitiesbull Replaces motor starter functionbull Digital readout in either Hz or RPMsbull Keypad enclosure (NEMA4X-Indoor) vsn be
mounted up to 100 from controller with cable assembly option
SYSTEM REQUIREMENTSbull In cases where the distance between the controller
and motor exceed 50 the use of a line reactor on load side is needed
bull XP motors must be UL listteedd for use with a Variable Frequency Drive
VARIABLE FREQUENCY DRIVE SELECTIONThere are some common guidelines in sizing a VFD for use on a AMETEK ROTRON blowers such as the allowable speed(table 1) for a given motor type To determine the required RPM to achieve a desired flow and pressure form a specific bloewr turn to the blower performance at variable speeds in section E of this catalog The required RPM must fall within the allowable rate of the motor being used
Motor Allowable Turndown Allowable Speedup
Standard 3600 RPM to 1800 RPM mdash3600 RPM to 900 RPM mdash
Inverter Motor 3600 RPM to 360 RPM 3600 RPM to 7200 RPM
Turndown of 101 is not typically done with regenerative blower designsFor all applications above 3600 RPM contact your Field Sales Engineer for proper horsepower sizing
Table 1
Specification
Model Number Part Number Description
IV101AE58 551529 1151 Up to 05 HP DR068-DR303 IV102AE58 551530 2301 Up to 05 HP DR068-DR303 IV101AL58 551531 1151 075 to 10 HP DR353-DR404 IV102AL58 551532 2301 or 3 075 to 10 HP DR353-DR404 IV103AL72 551533 4603 075 to 10 HP DR353-DR404 IV102AS58 551534 2301 or 3 15 to 20 HP DR454-DR505 IV103AS72 551535 4603 15 to 2 HP DR454-DR505 IV102K58 551536 2301 or 3 25 to 3 HP DR505-DR555 IV103K72 551537 4603 25 to 30 HP DR505-DR555 2301 IV102D58 551538 or 3 35 to 5 HP DR555-DR808D 4603 IV103D72 551539 35 to 5 HP DR555 to DR808D 2303 55
IV152AY58 551540 to 75 HP DR808-DR858 4603 55 to 75 IV152AY72 551541 DR808 ndash DR858 IV152BB58 551542 2303 8 to 10 HP DR858-DR909 IV153BB72 551543 4603 8 to 10 HP DR858-DR909 IV152BC58 551544 2303 105 to 15 HP DR909 IV153BC72 551545 4603 105 to 15 HP DR909 IV152BH58 551546 2303 155 to 20 HP DR9 DR14BH IV153BH72 551547 4603 155 to 20 HP DR9 DR14BH IV152BP58 551548 2303 205 to 30 HP DR13 DR14 IV153BP72 551549 4603 205 to 30 HP DR13 DR14 IV152BQ58 551550 2303 305 to 40 HP DR15 IV153BQ72 551551 4603 305 to 40 HP DR15 IV153ED72 551552 4603 505 to 60 HP DR15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
SINGLE-ENDED SIDE VIEW DOUBLE-ENDED SIDE VIEW
Air knives 30 and smallerMOUNTING VIEW
CAPPED END VIEW
CL CL25-8 NPT(TYP)
CL CL25-8 NPT(TYP)
GAP SETTINGRAIL(REF)
CL
PER MODEL
CL CL
25-20 UNC THRU
25-20 UNC X 75 LG
315 TYP
315TYP
L
458
458
22
22
075
175
10 STYP
L
PartModel Number
AK06S060 AK12S060 AK18S060 AK24S060 AK30S060 AK36S060 AK42S060 AK48S060 AK54S060 AK60S060
Specification Units 523489 552955 522949 553000 522950 523492 523493 523494 523495 523496
Length (L) Inches 930 1530 2130 2730 3330 4230 4830 5430 6030 6630 mm 2362 3886 541 6934 8458 10744 12268 13792 15316 1684
Slot Length Inches 6 12 18 24 30 36 42 48 54 60 mm 1524 3048 4572 6096 762 9144 10668 12192 13716 1524
Dimension S Inches 400 1000 1600 2200 2800 1700 2000 2300 2600 2900 mm 1016 254 4064 5588 7112 4318 508 5842 6604 7366
The ROTRON air knife is located at a strategicpoint in your assembly line conveyor beltarea Air ows from the blower into the airknife where a sheet of air is directed outthrough a proprietary linear nozzle designonto assembly line parts The opening canbe altered to adjust the air-ow rate thusvarying blow-o velocity to meet yourapplication requirements
Air KnivesAn Oil-free Blowing and Drying SystemCustom-t for Your Application
FEATURESbull Lightweight aluminum plenum and rail steel end cap
and cast-iron NPT angesbull Engineered extruded design to achieve 95 eciencybull Adjustable slot (pre-set at 0060) to control velocity
from 5000-35000 fpmbull Custom cut lengths to t system restraintsbull Oil-free and lower cost alternative to compressed air for
blow-o solution blow-back and drying applications
OPTIONSbull Chemical resistant designs utilizing Chem-Tough TM
chemically resistant surface conversion stainless steel hardware and nickel plated end caps and anges
bull Food processing grade designs utilizing Food-Tough TM
sanitary treatment surface conversion stainless steel hardware and nickel plated end caps and anges
bull Deionizers for sterile environments availablebull Mirror image single-ended models for above and below
conveyor operation
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800SCFM
Air Velocity
Precision Cleaning Air Knife and Blower Selection Chart
DR656
DR757
DR808 DR858
DR909
DRP9
DR979
DRP13
DR14
DRP15
6 knife
12 knife
18 knife
24 knife 30
knife 36 knife
42 knife
48 knife 54
knife60
knife
40000 FPM
35000 FPM
30000 FPM
25000 FPM
20000 FPM
15000 FPM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
air
These unique solenoid actuated diverter valves automatically change air piping from pressure to suction greatly enhancing blower versatility and productivity This valve is effective in blower applications that require frequent switching frompressure to suction and vice-versa They are costeffective as applications normally requiring twoblowers andor intricate piping systems may be accomplished with one blowerDiverter valves may be purchased as blowervalve assemblies or as separate stand-alone valve assemblies for use in other switched air applications
SPECIFICATIONSbull Aluminum body and spool assemblybull 303 stainless steel shaftbull 115 V-60 Hz solenoid valve
OPTIONSbull Corrosion resistant surface treatmentsbull International voltage and frequency (Hz)bull Application specific designs
DR 505 BLOWER WITH DIVERTER VALVEThe principle behind ROTRONrsquos diverter valve system is asimple one Some applications such as vacuum part pick-up airtables and pneumatic tube systems require both vacuum andpressure in their equipmentrsquos operation but not simultaneouslyThey eliminate the need for two sep-arate blowers andelaborate valving system or cyclingreversing a spinningblower impeller ROTRONrsquos diverter valve changes the airpassageways By utilizing the side vent ports for incoming oroutgoing air the equipmentpiping side of the valve changesfrom vacuum to pressure and back again by a signal sent to thesolenoid coil
PartModel Number
Specification Units 515554 037435 037482
Description - DR404 DR454 DR505 DR6 DR808 DR858 DR6 DR808 DR858 Ref Blower Model - Small Large Large Piping Flange - Threads Threads Threads Blower Flange - Face Threads Face
Dimension A Inches 765 925 925 mm 1943 235 235
Dimension B Inches 1422 2339 2339 mm 3612 5941 5941
Dimension C Inches 714 1093 1093 mm 1814 2776 2776
Dimension D Inches 250 355 355 mm 635 902 902
Dimension E Inches 500 710 710 mm 127 1803 1803
Dimension F Inches 150 250 250 mm 381 635 635
Dimension G Inches 150 250 250 mm 381 635 635
Consult factory for proper selection and application
SOLENOID
ENERGIZED POSITIONSUCTION AIR PATH
SOLENOID
DE-ENERGIZED POSITIONPRESSURE AIR PATH
A
D
BF
C
EG
EQUIPMENTPIPING SIDE ISO VALVE DRAWING
BLOWER SIDE
WORKINGPART
SUCTION PRESSURE
BlowerBlower
IN OUT IN OUT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
ROTRON RELEASED BLOWERS WITH DIVERTER VALVE MOUNTED Model Part No Mounted Components Diverter Valve Manifold
DR353BR58MV 080757DR404AL72MV 037749 517077DR404AL58MV 037715 DR454R72V 037605 515554
529397DR454R58V 037122DR505AS72MV 037709
517459DR505AS58MV 037554
037482 DR808AY72WV 080084
550667DR858BB72WV 080085
DIVERTER VALVE MANIFOLD
bull Models listed below include diverter valve and manifold
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Pressure amp Vacuum Arrangements
Pressure or vacuum guages should be located in the delivery line oriented as shown Assure that the guage is approxi-mately three pipe diameters from the blower delivery ange and that the relief valve is located at the same spacing from the guage 90deg elbows should be located at least ve pipe diameters from the blower delivery ange Elbows taps tees valves or other restrictions to air ow should not be located between the blower delivery ange and accessories described above
Failure to observe these precautions can result in false readings of guages and failure of the relief mechanism to protect the blower from overload
In order to avoid overheating or distortion of PVC pipe the rst ve to eight feet from the blower delivery ange on pressure systems should be metal
Typical Pressure System
Typical Vacuum System
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Motor Options
ROTRON strives to provide the most complete variety of desired options on our products including on our motors By using motor vendors of high quality and versatility we can provide motor features from multiple released designs to meet your needs (ie a Chem Processing Inverter Duty Explosion-proof motor with space heaters and drains wound for 380 V-50 Hzservice)
Design Consistency
ROTRON motors are engineered for us to integrally mount with our blower and maximize blower performance Our vendors are qualied by ROTRON (per motor part number) to ensure the blowersrsquo mechanical and electrical needs merge with your required features The basic motor requirements on our DRENCPHiE products include
bull NEMA approved
bull CE conformity (non-XP models)
bull UL amp CSA approved with symbol and file on nameplate
bull C-face mount
bull Permanently sealed bearings
bull Shaft end play run out and perpendicularity requirements above NEMA standards
bull Dual voltage and dual frequency (some models not feasible) to maximize use worldwide
bull Single Shafted Totally Enclosed Fan Cooled (TEFC) and Explosion-proof (XP) models
bull Double Shafted Open Drip Proof (ODP) models with dual internal fans for circulation
bull Class I Group D minimum on explosion-proof motors many are Class I Group D Class II F amp G
bull Commercial Spa (SPA-ODP) motors with automatic thermaloverload protection and industry specied terminal strip
Standard Motor Variations
Chemical Processing (CP) features are added to TEFC XP or HiE designs for corrosive gas service Marine Duty service and sanitary (foodpharmaceutical) service
bull 303 stainless steel shaft
bull Cast iron and steel frame epoxy painted or zinc plated
bull Zinc plated hardware
bull Stainless steel nameplate
bull Non-hygroscopic insulation double dipped and baked stator
bull Epoxy coating on rotor
bull Gaskets and joint sealers on all metal-to-metal surfaces
bull Oversized conduit box
High Efficiency (HiE) features are added to TEFC ODP XP or CP motors for maximum motor eciency and life ROTRON HiE motors carry extra phase-to-phase protection for use withinverters between a 1750-3500 RPM range
Inverter Duty features are added to TEFC ODP XP or CP for use with InvertersVariable Speed Drive Controllers A wide range of RPM can be handled and should be specified at time of quote For best compatibility an inverter should be matched to the motor manufacturers design
Project Specic Motor Variations
There are no limits to the options you can select or request for your product Routine motor options include
bull International voltage amp frequency (Hz)
bull Different shaft material
bull Oversized andor Nema 4 intent T-box
bull Space heaters
bull Drains
bull Regreasable bearings
bull Tropicalized windings
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Typical Sealing Options
Lo-Leaktrade LIP SEAL Option
The Lo-LeaktradeLip Seal option is available to control gas leakage for all DR models and is standard on all EN and CP models Features include Lip seals to prevent leakage at the motor shaft RTV sealingcompound is used to cut o all leakage paths at the blowerrsquos metal-to-metal surfaces Castings are vacuum impregnated to prevent leakage through castings Estimate leakage rate = 25 ccmin or less
Double Face Carbon Seal Option
For further minimization of gas leakage on all DR EN and CP models a pair of face seals work against each other on opposite sides of a common mating ring to eectively reduce gas leakageat the motor shaft The face shields are continually lubricated from a reservoir to prolong seal life The seal is completed by installing the blower to motor bolts with O-rings and sealingthe covers to the housing with an RTV sealing compound O-rings are also placed between the pipe anges and the manifold All castings are vacuum impregnatedEstimate leakage rate = 05 ccmin or less
Hermetically Sealed Spiral Containment Option
The containment option utilizes a series of O-rings to control gas leakage in Spiral blower models The O-rings are placed at critical locations on the blowerrsquos housing and covers to contain gas leakage
Hermetically Sealed Mag Drive Option
On DR EN and CP 101 units a magnet drive option has been an alternative for complete gas containmentO-rings are used throughout the product and magnets attached to the motor shaft spin magnets inside the blower without shaft penetration Estimated leakage rate = 0001 ccmi
Nitrogen Purge Blanket Option
The nitrogen purge option is a carrier designed to accept a nitrogen line which will purge the space outside the shaft hole Purges can be designed to bleed the nitrogen into the process called a blanket or the carrier can have a second tap to carry away the leaking contaminants
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chem-Toughtrade Chemical Resistance
To stand up in corrosive and hazardous environments chemical processing blowers have to be tough Thatrsquos why Ametek ROTRON routinely applies Chem-Toughtrade ROTRONrsquoS own engineered and proprietary process whenever it builds blowers for handling chemical (vapor) streams Chem-Toughtrade combines the advantages of aluminum oxide ceramic and selected uorocarbons to give ROTRON blowers unheard-of levels of chemical resistance hardness abrasion resistance permanent lubricity and more
Chem-Toughtrade Brings You the Rotron Advantage
Through this unique proprietary process Chem-Toughtrade gives ROTRON blowers these advantages
bull Outstanding Chemical ResistanceTime after time Chem-Toughtrade nishing shows extremely high resistance to most common chemicals as well as dramatically improved corrosion resistance over regular hard anodizing Chem-Toughtrade allows aluminum to achieve equivalent corrosion resistance as teonreg 90-day immersion in acid or alkaline solution (pH 40-85) has no eect neither does prolonged exposure to salt water Far exceeds military specication requirements for salt spray
bull Abrasion Resistance Equivalent to Steel Excellent for smooth surfaces Chem-Toughtrade surfaceconversion provides higher wear resistance than eithercase-hardened steel or hard-chrome plate Rub any other metal against the Chem-Toughtrade nish and the metal will show nothing but the slightest wear Chem-Toughtrade provides a perfect bond to the parent metal
bull Increased HardnessWith an equivalent hardness of Rc 40-60 Chem-Toughtrade is approximately le-hard ndash the hardness of nitrated steel Because the Chem-Toughtrade surface becomes an integral part of the metal it simply cannot peel or chip ndash neither can it bescratched aked or nicked under ordinary conditions
bull Permanent Dry LubricityBy infusing polymers into aluminum Chem-Toughtrade gives the resulting surface a high degree of permanent lubricity and resistance to moisture The polymers also level o surface asperities signicantly reducing surface tension The result blowers converted with Chem-Toughtrade have a longer life operate more eciently and call for less maintenance
bull Other Proprietary ProcessesFood-Toughtrade uses the same unique process as Chem-Toughtrade and is designed for the food processing medical andpharmaceutical markets Food-Toughtrade has USDA approval and meets FDA guidelines
Chem-Toughtrade at Work
Chem-Toughtrade employs the advantages of anodizing hardcoat plating low-friction polymers and dry lubricants to become an integral part of the blowerrsquos molecular structure
Specically Chem-Toughtrade rst converts the aluminum surface to aluminum oxide forming a new ceramic-like surface The water in the ceramic is replaced with Teonreg adding a multi-functional dimension to the surface in the process the aluminum crystals expand and form anchor crystals that remain hygroscopic for a short time Then under controlled conditions particles of the specied polymer are infused to interlock with these anchor crystals The new surface extends 5 mil above and below the original aluminum surface ndash and forms a permanent molecular bond with the metal
The result a plasticceramic surface thatrsquos harder than steel is continuously lubricating and resists damage from chemicals like no other The kind of protection you need for your chemical processing blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Acetaldehyde B C A A A A AAcetate Solv B B A A A B A B Acetic Acid B D C A B A B AAcetic Anhydride B B D A B A A B AAcetone A A A A A A A B AAcetylene A A A A A A A Acrylonitrile B C A A C BAlcohols
Amyl C C C A A A A ABENZYL B A A AButyl B C C A A A A ADiacetone A A A A AEthyl B A A A A A AHexyl A A A A AIsobutyl B A A A AIsopropyl B C A A A AMethyl B A A A A A A AOctyl A A A A APropyl A A A A A A
Aluminum Chloride 20 B D A D C D AAluminum Chloride D D B A C D C AAluminum Hydroxide A D A A A A A Alum Potassium
Sulfate (Alum) 10 A D A A A BAlum Potassium
Sulfate (Alum) 100 B A A D A B BAluminum Sulfate A D A A C C A AAmines A A B A A A A AAmmonia 10 A A AAmmonia Anhydrous B D B A A B A A AAmmonia Liquids D A A A A A A BAmmonia Nitrate C A A A A Ammonium Biuoride D C A BAmmonium Carbonate C C B A B A A A BAmmonium Chloride C D D A C A C A AAmmonium Hydroxide C A C A A A A A AAmmonium Nitrate B A D A A A A A AAmmonium Persulfate C D A A A A A AAmmonium Phosphate Dibasic A A A AB D A BAmmonium Phosphate Monobasic A A A AB A A Ammonium Phosphate Tribasic A A A AB C D A BAmmonium Sulfate B C C A C A B A AAmyl-Acetate B C A B A A C AAmyl Alcohol B A A A A AAmyl Chloride D A A C B AAniline C C A B A A A BAnti-Freeze A B C A A A AAntimony Trichloride D A D D AAromatic Hydrocarbons A A A A Arsenic Acid D D D A B A A
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Barium Carbonate B B B A B A A A ABarium Chloride D D C A C A A A ABarium Hydroxide D C C A B C A A BBarium Sulfate D C C A B A A A ABarium Sulde D C C A B A A Benzaldehyde B B A A A A A ABenzene B B C A B A A A BBenzoic Acid B D A B A A A ABenzol B A A A ABorax (Sodium Borate) C A C A A A A ABoric Acid B D A B A A A ABromine (Wet) D D D A D D D D AButadiene A C C A A A A Butane A C C A A A A Butanol A A A A AButylene A A A A A A Butyl Acetate A A A C AButyric Acid B D A B B A A ACalcium Bisulfate D D A C D A Calcium Bisulde C A B ACalcium Bisulte C A D A ACalcium Carbonate C D A B A A A ACalcium Chloride C C A C A D C ACalcium Hydroxide C A B A A ACalcium Hypochlorite C D A D A C C BCalcium Sulfate B A B A A A BCarbon Bisulde A B B A A A Carbon Dioxide (Wet) C C A A A ACarbon Disulde C B C A B A Carbon Monoxide A A A Carbon Tetrachloride C C D A B C B A ACarbonated Water A D B A A A Carbonic Acid A D A B A B A AChloracetic Acid C D A D D D D AChlorinated Glue D D A A
D C A D D D AChlorine Anhydrous LiquidChlorine (Dry) D A A B A A AChlorine Water D D A D D BChlorobenzene (Mono) B B C A A A A AChloroform D D C A A A A A AChlorosulfonic Acid D D A D D D BChlorox (Bleach) C D C A A A AChromic Acid 5 C D A A B AChromic Acid 50 C D A C B B ACitric Acid C D A A A A ACitric Oils C A A Copper Chloride D D A C D D B ACopper Cyanide D D A A A A ACopper Floborate D D A D D BCopper Nitrate D A B A A B A
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Chemical Resistance Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Copper Sulfate (5 Solution) A A A AD D A AABsloserCBAABACdicA cilyserCAAAenaxeholcyCAAAAstnegreteDAAAAAAleuFleseiDAAAAenimalyhteiDAAB
A BseyD
Epsom Salts (Magnesium Sulfate) A A A BAAAenahtE
E the Ar B A A A A BBAAACBetatecA lyhtE
ADCBC C C A A A BD C A A A BA B C A A A AA A A
edirolhC lyhtE A A A BEthylene ChlorideEthylene DichlorideEthylene GlycolEthylene Oxide
AAAADBsdicA yttaFBDDDADDedirolhC cirreF
Fer ric Nit rat De A A A A AAACAADD
D D A D D BD D D A B A C B
etafluS cirreFFerrous ChlorideFerrous Sulfate
ADDDCDDDeniroulFBBADDdicA cicilisoulFBAAAAADAedyhedlamroF
CADDDdicA cimroF A B B AAAABCB
B A D 11 noerF
Freon 12 (Wet)AB22 noerFAB311 noerFABFT noerFAAAAABCAsliO leuFAAAAAAniseR naruFBAAAAAAlarufruFAAABADDAdicA cillaG
AAAAAenilosaG A A A AAABBAenirecylG A A A A
AAAABAenatpeHAAAAABA
A A A A A A A A A A A D D D A D D D D AD D A D C A AD D A D D D BD D A D D D BD D A D D CA C A A A A C AD D A D D D BD D A C D C
enaxeHHydraulic Oils (Petroleum)Hydraulic Oils (Synthetic)Hydrobromic AcidHydrochloric Acid (Dry Gas)Hydrochloric Acid (20)Hydrochloric Acid (37)Hydrochloric Acid 100Hydrocyanic AcidHydrouoric Acid (20)Hydrouoric Acid (75)
Hydrouoric Acid 100 D D D A D D D BD D A D D BHydrouosilicic Acid (20)
Hydrouosilicic Acid C A D D CHydrogen Gas A B B A A A A Hydrogen Peroxide 10 A D A C C AHydrogen Peroxide A D D A A B A AHydrogen Sulde
Aqueous Solution C D A A A C AHydrogen Sulde (Dry) D B B A A C A AHydroxyacetic Acid (70) D Ink C D D A A A Iodine D D A D D D BIodoform A C B A B D A Isotane A Isopropyl Acetate C B Isopropyl Ether A A A A A Jet Fuel (JP3 JP4 JP5) A A A A A A A Kerosene A A B A A A A A AKetones B A A A A A A ALacquers A C C A A A Lactic Acid C D D A A A B C ALead Acetate D D A B A A ALubricants A A A A AMagnesium Chloride D D C A B B B A AMagnesium Hydroxide D B B A A A A AMagnesium Sulfate B C B A B B A BMaleic Acid B B A C A A A AMalic Acid C D A B A A A
D D D A D D D D BMercuric Chloride (Dilute Solution)Mercuric Cyanide D D A A A A Mercury C A A A A A A A AMethane A A A A A A A A AMethyl Acetate A B A A A AMethyl Acetone A A A A A A Methyl Alcohol 10 C B A A A AMethyl Butyl Ketone A A Methyl Cellosolve A Methyl Chloride D A C A AMethyl Ethyl Ketone A A A A AMethylamine A B B A A Methylene Chloride A B A A A A ANaptha A B B A A A A A ANapthalene B B A A B A B ANickel Chloride D D A A B ANickel Sulfate D D D A B A B BNitric Acid (10 Solution) D D D A A A A A ANitric Acid (20 Solution) D D A A A A ANitric Acid (50 Solution) D D A
B D A D B A B
A A A ANitric Acid
(Concentrated Solution)
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Nitrobenzene C B B A B A B BOleum B B A B A Oxalic Acid (cold) C D D A C A B A BPentane A B B A A C C BPerchloroethylene A B B A B A A Petrolatum B C C A A A Phenol 10 A B D A B A A BPhenol (Carbolic Acid) B D D A B A A A APhosphoric Acid
(to 40 Solution) D D A B A A APhosphoric Acid
(40-100 Solution) D D A C B B APhosphoric Acid (Crude) D D D A D C C A
D A A A Phosphoric Anhydride (Molten)Photographic (Developer) C D C A C APhthalic Anhydride B C C A B A B APicric Acid C D D A B A A APotash C B A A APotasium Bicarbonate C D A A B BPotassium Bromide C D D A A A B BPotassium Carbonate C B B A B A A APotassium Chlorate B B B A B A A A BPotassium Chloride B B B A C A A B APotassium Chromate A A B B B
D B B A BPotassium Cyanide Solutions A B A APotassium Dichromate A B C A B A A A BPotassium Ferrocyanide C C A B A A B
D C A A APotassium Hydroxide (50) B B B APotassium Nitrate B B A B A B A BPotassium Permanganate B B B A B A B B BPotassium Sulfate A B B A B A B B APotassium Sulde B B B A A A A BPropane (Liquied) A B A A A A Propylene Glycol A B B A B B A Pyridine B B A A C B Pyrogallic Acid B B B A B A A A ASilver Bromide D C C B Silver Nitrate D D D A B A B A ASodium Acetate B C C A B A A B ASodium Aluminate C C A B A BSodium Bicarbonate A C C A B A A A Sodium Bisulfate D D D A A A A BSodium Bisulte A D A A A BSodium Borate C C C A B A A ASodium Carbonate C B B A B A B B ASodium Chlorate B C A B A A BSodium Chloride C B C A B A C B ASodium Chromate D B B A A A A BSodium Cyanide D B B A B A A Sodium Fluoride C D D A B C C A
Sodium Hydrosulte A A ASodium Hydroxide (20) D A A
D B A A B AD C A A D BD C A A D B
A A A ASodium Hydroxide (50 Solution)Sodium Hydroxide (80 Solution)Sodium Hypochlorite (to 20)Sodium Hypochlorite D D D A D A ASodium Hyposulfate D A A A Sodium Metaphosphate A B B A A A Sodium Metasilicate B C C A A A Sodium Nitrate A A B A B A A A BSodium Perborate B B B A B C Sodium Peroxide C D C A B A A BSodium Polyphosphate
(Mono Di Tribasic) D A A A ASodium Silicate C B A B A B A BSodium Sulfate B A B A B A A C BSodium Sulde D A B A B A B BSodium Sulte C A A C C A
B C B A A A A Sodium Thiosulphate (ldquoHypordquo)Stannic Chloride D D D A D D D BStannous Chloride D D D A D D C AStearic Acid B C C A B A A A AStoddard Solvent A B B A A A A A AStyrene A A A A A A Sulfate Liquors B C C ASulfur Chloride D A D D D Sulfur Dioxide A A A A C BSulfur Dioxide (Dry) A A B A A A A ASulfur Trioxide (Dry) A B B A A A C Sulfuric Acid (to 10) C D A D C C ASulfuric Acid (10-75) D D A D D D BSulfurous Acid C D D A C C B C BTannic Acid C C C A B A A A BTanning Liquors C A A A ATartaric Acid C D D A B A B B BTetrahydrofuran D D A A A A Toluene Toluol A A A A A A A ATrichlorethane C C A C A ATrichlorethylene B C B A B A A AWater Acid Mine C C A A
B D A A A Water Distilled Lab Grade 7Water Fresh A B D A A A A Water Salt B D A A Weed Killers C A A Whiskey and Wines D D D A A A A A Xylene A A B A A A A AZinc Chloride D D D A D A B B BZinc Hydrosulphite D D A Zinc Sulfate D C D A B A A A B
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Flow
bull Volume RateTimebull ROTRON charts are in SCFM m3min or LSbull SCFM = Standard Cubic Feet Per Minute (American) where
temperature = 68degF air density = 0075 lbcubic foot and altitude = 0 feet above sea level
bull M3min = Cubic Meters Per Minute (Metric)bull Lsec = Liters Per Second (Metric)bull 1 m3min = 353 SCFMbull 1 Lsec = 2119 SCFMbull See Standard Engineering Conversions for other flows on
pg I-2
Throughout our catalog you will find terminology used for air moving selection and product sizing Below are a few of the key terms
Specic Gravity
bull Density Ratio Relative to Airbull Standard Air SG = 10bull Methane SG = 055bull See Specific Gravity Chart for other gases on pg I-4
Pressure
bull ForceAreabull ROTRON charts are in IWG PSIG MM of Water IHG or mbarbull IWG = Inches of Water Gauge (American)bull PSIG = Pounds Per Square Inch Gauge (American)bull MM of Water = Millimeter of Water Gauge (Metric)bull IHG = Inches of Mercury Gauge (American)bull mbar = Millibar Gauge (Metric)bull PSIA = Pounds Per Square Inch Absolute (American)bull 277 IWG = 1 PSIGbull 70358 MM of Water = 1 PSIGbull 2036 IHG = 1 PSIGbull 0069 Bars = 69 mbar = 1 PSIGbull Standard Atmosphere = 0 PSIG = 147 PSIAbull See Basic Fan Laws Chart for correcting pressure due to speed
or density changes on pgs I-5 and I-6
Density
bull WeightVolumebull Standard Air = 0075 lbcubic footbull See Density Chart for other gases on pg I-4bull See Density Correction Chart due to altitude and temperature
changes on pg I-3
Velocity
bull DistanceTime or FlowAreabull FPM = Feet Per Minute (American)bull MPH = Miles Per Hour (American)bull Mmin = Meters Per Minute (Metric)bull Kmh = Kilometers Per Hour (Metric)bull 88 FPM = 1 MPHbull 2682 Mmin = 1 MPHbull 1609 Kmh = 1 MPHbull See Standard Engineering Conversion Chart for other
velocities on pg I-2bull See Orifice Flow Calculation Chart for air flow equations on
pg I-7
Pressure Drop Back Pressure Impedance
bull Friction causes air to slow down and lost energy is measured in pressure drop terms
bull Typical pressure drop areas include piping elbows accessories and system
bull Each fixed system has a fixed system impedance caused by a single or multiple pressure drop points
bull Changing the system impedance will cause blowers work point to change
bull Changing the blower with fixed system impedance will change the working back pressure
bull See Friction Loss Per Foot of Tubing and Fitting Charts on pg I-8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Engineering Conversion
MULTIPLY BY TO OBTAINAtmospheres 760 Cms of MercuryAtmospheres 2992 Inches of MercuryAtmospheres 3390 Feet of WaterAtmospheres 10333 KgsSq InchAtmospheres 1013 x 105 PascalsAtmospheres 1470 PoundsSq InchAtmospheres 760 TorrsBars 09869 AtmospheresBars 1 x 106 DynesSq CmBars 1020 x 104 KgsSquare MeterBars 1450 PoundsSq InchBritish Thermal Units 02520 Kilogram-CaloriesBritish Thermal Units 7775 Foot-PoundsBritish Thermal Units 3927 x 10-4 Horsepower-HoursBritish Thermal Units 1054 JoulesBritish Thermal Units 1075 Kilogram-MetersBritish Thermal Units 2928 x 10-4 Kilowatt-HoursCentimeters of Mercury 001316 AtmospheresCentimeters of Mercury 04461 Feet of WaterCentimeters of Mercury 1360 KgsSquare MeterCentimeters of Mercury 01934 PoundsSq InchCentimetersSecond 1969 FeetMinuteCentimetersSecond 06 MetersMinuteCubic Centimeters 3531 x 10-5 Cubic FeetCubic Centimeters 6102 x 10-2 Cubic InchesCubic Centimeters 10-6 Cubic MetersCubic Centimeters 10-3 LitersCubic Feet 2832 x 104 Cubic CmsCubic Feet 1728 Cubic InchesCubic Feet 002832 Cubic MetersCubic Feet 003704 Cubic YardsCibic Feet 7481 GallonsCubic Feet 2832 LitersCu Ft of Water (60degF) 6237 PoundsCubic FeetMinute 4720 Cubic CmsSecCubic FeetMinute 04720 LitersSecondCubic FeetMinute 624 Lbs of WaterMinCubic Inches 1639 Cubic CentimetersCubic Inches 5787 x 10-4 Cubic FeetCubic Inches 1639 x 10-5 Cubic MetersCubic Inches 2143 x 10-5 Cubic YardsCubic Meters 106 Cubic CentimetersCubic Meters 3531 Cubic FeetCubic Meters 61023 Cubic InchesCubic Meters 1308 Cubic YardsCubic Yards 7646 x 105 Cubic CentimetersCubic Yards 27 Cubic FeetCubic Yards 46656 Cubic InchesCubic Yards 07646 Cubic MetersFeet 3048 CentimetersFeet 12 InchesFeet 03048 MetersFeet 13 YardsFeet of Air
(1 atmosphere 60degF) 530 x 10-4 PoundsSquare InchFeetMinute 05080 CentimetersSecFeetMinute 001667 FeetSecondFeetMinute 001829 KilometersHourFeetMinute 03048 MetersMinuteFeetMinute 001136 MilesHourGramsCu Cm 6243 PoundsCubic FootHorsepower 4244 British Thermal UnitsMinHorsepower 33000 Foot-PoundsMinHorsepower 1070 Kg-CaloriesMinHorsepower 7457 WattsHorsepower-Hours 2547 British Thermal UnitsInches 2540 CentimetersInches 103 MilsInches of Mercury 003342 AtmospheresInches of Mercury 1360 Inches of WaterInches of Mercury 3453 KgsSquare MeterInches of Mercury 2540 Mms of MercuryInches of Mercury 04912 PoundsSquare InInches of Water 0002458 AtmospheresInches of Water 007355 Inches of MercuryInches of Water 2540 KgsSquare MeterInches of Water 5204 PoundsSquare FtInches of Water 003613 PoundsSquare In
MULTIPLY BY TO OBTAINKGSCubic Meter 006243 PoundsCubic FootKilometers 3281 FeetKilowatts 5692 British Thermal UnitsMinKilowatts 7376 Foot-PoundsSecKilowatts 1341 HorsepowerKilowatts 1434 Kg-CaloriesMinKilowatt-Hours 3415 British Thermal UnitsLiters 103 Cubic CentimetersLiters 6102 Cubic InchesLiters 10-3 Cubic MetersLog10N 2303 LogEN or Ln NLog N or Ln N 04343 Log10NMeters 100 CentimetersMeters 32808 FeetMeters 3937 InchesMeters 10-3 KilometersMetersMinute 1667 CentimetersSecMetersMinute 3281 FeetMinuteMetersMinute 006 KilometersHourMetersMinute 003728 MilesHourMiles 5280 FeetMiles 16093 KilometersMiles 1760 YardsMilesHour 4470 CentimetersSecMilesHour 88 FeetMinuteMilesHour 1467 FeetSecondMilesHour 16093 KilometersHourMilesHour 2682 MetersMinuteMms of Mercury 00394 Inches of MercuryMms of Mercury 13595-3 KgsSquare CmMms of Mercury 001934 PoundsSquare InchPints (Liq) 2887 Cubic InchesPints (US liquid) 473179 Cubic CentimetersPints (US liquid) 16 Ounces (US fluid)Pounds 444823 DynesPounds 4536 GramsPounds 16 OuncesPounds of Carbon to CO2 14544 British Thermal Units (mean)Pounds of Water 2768 Cubic InchesPounds of Water 01198 GallonsPounds of Water
Evaporated at 212degF 9703 British Thermal UnitsPoundsCubic Foot 1602 KgsCubic MeterPoundsSquare Foot 4882 KgsSquare MeterPoundsSquare Inch 006804 AtmospheresPoundsSquare Inch 277 Inches of WaterPoundsSquare Inch 2036 Inches of MercuryPoundsSquare Inch 7031 KgsSquare MeterPoundsSquare Inch 6895 x 103 PascalsPoundsSquare Inch 51715 Millimeters of Mercury at 0degCSquare Centimeters 1973 x 105 Circular MilsSquare Centimeters 1076 x 10-3 Square FeetSquare Centimeters 01550 Square InchesSquare Feet 9290 Square CentimetersSquare Feet 009290 Square MetersSquare Inches 1273 x 106 Circular MilsSquare Inches 6452 Square CentimetersSquare Inches 6944 x 10-3 Square FeetSquare Inches 106 Square MilsSquare Inches 6452 Square MillimetersSquare Kilometers 1076 x 106 Square FeetSquare Kilometers 106 Square MetersSquare Kilometers 1196 x 106 Square YardsSquare Meters 10764 Square FeetSquare Meters 1196 Square YardsTemp (Degs C) + 273 1 Abs Temp (Degs C)Temp (Degs C) + 178 18 Temp (Degs Fahr)Temp (Degs F) + 460 1 Abs Temp (Degs F)Temp (Degs F) -32 59 Temp (Degs Cent)Watts 005692 British Thermal UnitsMinWatts 107 ErgsSecondWatts 4426 Foot-PoundsMinWatts 1341 x 10-3 HorsepowerWatts 001434 Kg-CaloriesMinWatts 10-3 KilowattsWatts-Hour 3415 British Thermal UnitsWatts-Hour 1341 x 10- HorsepowerHoursWatts-Hour 10-3 Kilowatt-Hours
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Density Correction Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Specic Gravity and Density of Various Gases at 60degF (1 ATM)
ChemicalFormula
Density(lbscu ft)
Gas or Vapor Specic Gravity
Acetylene 0899 0686Air 100 0763Ammonia 0587 0454Argon 1377 1053Benzene 270 205Carbon Dioxide 1539 1166Chlorine 2448 0738Ethane 1038 0799Ethylene 0969 0739Helium 0138 01054Hydrogen 00695 00531Hydrogen Sulde 119 0897Methane 0555 0424Methyl Chloride 1785 1356Nitrogen 0967 0738Oxygen 1105 0843Propane 155 1180Sulfer Oxide 226 1720Water Vapor 0622
C2H2
-NH3
AC6H6
CO2
CI2
C2H6
C2H4
HeH2
H2SCH4
CH3CIN2
O2
C3H8
SO2
H2O 0373
Explosive Atmosphere Classication
NEMA Classications
North American European
Class I Zone 1Group A AcetyleneGroup B Group II C
Group II CHydrogen or equivalent hazard
Group C Group II B Ethyle ether vapors ethylene orcyclopropane
Group D Group II A Gasoline hexane naptha benzenebutane alcohol acetone benzol lacquer vapors or natural gas
Class IIGroup E Metal dustGroup F mdash
mdashCarbon black coal or coke dust
Group G mdash Flour starch or grain
Temperature Conversion Chart
degC Temp degF degC Temp degF degC Temp degF degC Temp degF-789 -110 -166 17 35 950 272 81 1778 182 360 680-733 -100 -148 22 36 968 278 82 1796 188 370 698-678 -90 -130 28 37 986 283 83 1814 193 380 716-622 -80 -112 33 38 1004 289 84 1832 199 390 734-567 -70 -94 39 39 1022 294 85 1850 204 400 752-511 -60 -76 44 40 1040 300 86 1868 210 410 770-456 -50 -58 50 41 1058 306 87 1886 216 420 788-400 -40 -40 56 42 1076 311 88 1904 221 430 806-344 -30 -22 61 43 1094 317 89 1922 227 440 824-289 -20 -4 67 44 1112 322 90 1940 232 450 842-233 -10 14 72 45 1130 328 91 1958 238 460 860-178 0 32 78 46 1148 333 92 1976 243 470 878-172 1 338 83 47 1166 339 93 1994 249 480 896-167 2 356 89 48 1184 344 94 2012 254 490 914-161 3 374 94 49 1202 350 95 2030 260 500 932-156 4 392 100 50 1220 356 96 2048 266 510 950-150 5 410 106 51 1238 361 97 2066 271 520 968-144 6 428 111 52 1256 367 98 2084 277 530 986-139 7 446 117 53 1274 372 99 2102 282 540 1004-133 8 464 122 54 1292 378 100 2120 288 550 1022-128 9 482 128 55 1310 43 110 230 293 560 1040-122 10 500 133 56 1328 49 120 248 299 570 1058-117 11 518 139 57 1346 54 130 266 304 580 1076-111 12 536 144 58 1364 60 140 284 310 590 1094-106 13 554 150 59 1382 66 150 302 316 600 1112-100 14 572 156 60 1400 71 160 320 321 610 1130
-94 15 590 161 61 1418 77 170 338 327 620 1148-89 16 608 167 62 1436 82 180 356 332 630 1166-83 17 626 172 63 1454 88 190 374 338 640 1184-78 18 644 178 64 1472 93 200 392 343 650 1202-72 19 662 183 65 1490 99 210 410 349 660 1220-67 20 680 189 66 1508 100 212 413 354 670 1238-61 21 698 194 67 1526 104 220 428 360 680 1256-56 22 716 200 68 1544 110 230 446 366 690 1274-50 23 734 206 69 1562 116 240 464 371 700 1292-44 24 752 211 70 1580 121 250 482 377 710 1310-39 25 770 217 71 1598 127 260 500 382 720 1328-33 26 788 222 72 1616 132 270 518 388 730 1346-28 27 806 228 73 1634 138 280 536 393 740 1364-22 28 824 233 74 1652 143 290 554 399 750 1382-17 29 842 239 75 1670 149 300 572 404 760 1400-11 30 860 244 76 1688 154 310 590 410 770 1418-06 31 878 250 77 1706 160 320 608 416 780 1436
0 32 896 256 78 1724 166 330 626 421 790 145406 33 914 261 79 1742 171 340 644 427 800 147211 34 932 267 80 1760 177 350 662 432 810 1490
In the center column nd the temperature to be converted The equivalent temperature is in the left column if converting to Celsius and in the right column if converting to Fahrenheit
degF = 95C + 32 ABSOLUTE RANKIN (R) R = degF + 460degC = 59 (F - 32) ABSOLUTE KELVIN (K) K = degC + 273
Ref NEMA Standards Publication Pub No 1CSndash1970
NEMA Type 1 ndash General Purpose ndash IndoorType 2 ndash Dripproof ndash IndoorType 3 ndash Dusttight Raintight and Sleet (Ice)
Resistant ndash Outdoor3R ndash Rainproof and Sleet (Ice) Resistant
ndash Outdoor3S ndash Dusttight Raintight and Sleet (Ice)
Proof ndash OutdoorType 4 ndash W atertight and Dusttight ndash Indoor
4X ndash W atertight Dusttight and CorrosionResistant ndash Outdoor
Type 5 ndash Superseded by Type 12 for ControlApparatus
Type 6 ndash Submersible Watertight Dusttight andSleet Resistant ndash Indoor and Outdoor
Type 7 ndash Class I Group A B C or D HazardousLocations Air Break Equipment ndash Indoor
Type 8 ndash Class I Group A B C or D Hazardous Locations Oil-immersed Equipment ndash Indoor
Type 9 ndash Class II Group E F or G HazardousLocations Air-break Equipment ndash Indoor
Type 10 ndash Bureau of MinesType 11 ndash Corrosion Resistant and Dripproof
Oil-immersed ndash IndoorType 12 ndash Industrial Use Dusttight and Driptight
ndash IndoorType 13 ndash Oiltight and Dusttight ndash Indoor
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Physical Laws for Blower Applications
In the following formulae these symbols are used
P ndash Pressure in pounds per square inch (PSI) or inches ofmercury column (inches Hg)
CFM ndash Volume in cubic feet per minuteRPM ndash Speed in revolutions per minuteD ndash Density in pounds per cubic foot (lbscu ft)H ndash Height of air or gas column (ft)SG ndash Specic Gravity (ratio of density of gas to the density
of air)
ldquoStandard Airrdquo ndash Air at 68degF (absolute temperature 528deg) and 2992rdquo Hg (barometric pressure at sea level) The density of such air is 0075 lbscu ft and the specic volume is 1329 cu ftlb The specic gravity is 10
The outlet pressure of a blower depends on the condition of the air or gas at the inlet The inlet condition is inuenced bya ndash Specic gravity (The ratio of density of the gas to density of
standard air)b ndash Altitude (location of blower)c ndash Temperature of inlet air
Volume
Pressure
The Volume changes in direct ratio to the speedExample ndash A blower is operating at 3500 RPM and delivering 1000 cfm If the speed is reduced to 3000 RPM what is the new volume
Basic Fan Laws Chart
V REWOPESROHERUSSERPEMULOVELBAIRA
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio
Varies DIRECT with Density Ratio Varies DIRECT with Density Ratio
Varies with CUBE of Speed Ratio
CFM 2 = CFM 1 ( RPM 2 ) P 2 = P 1 ( RPM 2 )2 HP 2 = HP 1 ( RPM 2 )3
RPM 1 RPM 1 RPM 1
WHEN DENSITY CHANGES Does Not Change
P 2 = P 1 ( D2 ) HP 2 = HP 1 ( D2 )D1 D1
V 1 = Original Volume (1000 CFM)V 2 = New VolumeRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
V 2 = V 1 ( RPM 2 )1= 1000 x ( 3000 )1
= 1000 x 857 = 857 CFMRPM 1 3500
Pressure (barometric) varies in direct proportion toaltitudeExample ndash A blower is to operate at an elevation of 6000 feetand is to deliver 3 PSI pressure What pressure (standard air)blower is required
Pressure = 3 x 2992
= 375 or 3 34 lb2398
If it is desired to determine what pressure a 3 lb (standard air)blower will deliver at 6000 feet ndash
Pressure = 3 x 2398
= 24 or about 2 12 lb2992
When a blower is to operate at a high altitude it is frequentlyspecied that the blower be capable of handling a given vol-ume of ldquostandard airrdquo It is then necessary to determine theequivalent volume of air at the higher altitudeExample ndash A blower is to operate 6000 feet altitude and is tohandle 1000 CFM of standard air What is the CFM of air theblower must handle at 6000 feet altitude
Let V 1 = Volume of standard air (1000 CFM)V 2 = Volume of thinner airHg1 = Barometric pressure sea level (2992)Hg2 = Barometric pressure 6000rsquo (2398)
V 2 = V 1 x Hg
1 = 1000 x 2992
= 1248 CFMHg 2 2398
The pressure changes as the square of the speed ratio
Example ndash A blower is operating at a speed of 3500 RPM anddelivering air at 50 pounds pressure If the speed is reduced to3000 RPM what is the new pressure
P 1 = Original Pressure (5 lbs)P 2 = New PressureRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
P 2 = P 1 ( RPM 2 )2= 5 x ( 3000 )2
= 5 x 735 = 368 poundsRPM 1 3500
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Pressure (Contrsquod)
Horsepower
The Air Density varies in inverse proportion to theabsolute temperatureExample ndash A blower is to handle 200degF air at 3 PSI pressureWhat pressure (standard air) blower is required
Let P 1 = Pressure hot air (3 PSI)P 2 = Pressure standard airAT 1 = Absolute temperature hot air (200+460=660degF)AT 2 = Absolute temperature standard air (68+460=528degF)
P 2 = P 1 x AT
1 = 3 x 660 = 375 or 3 34 lbAT 2 528
A blower is capable of delivering 3 PSI pressure with standardair What pressure will it develop handling 200degF inlet air
P 1 = P 2 x AT
2 = 3 x 528 = 24 or about 2 12 lbAT 1 660
Pressure varies in direct proportion to the densityExample ndash A 3 lb (standard air) blower is to be used to handlegas having a specic gravity of 05 What pressure does theblower create when handling the gas
Let Pa = Air pressure (3 lb)Pg = Gas pressureSG = Specic gravity of gas (05)
Pg = Pa x SG = 3 x 5 = 15 lb
If we are required to handle a gas having a specic gravity of 05at 15 lb pressure we can determine the standard air pressureblower as follows
Let Pa = Pg
= 15
= 3 lbSG 5
The following table gives the barometric pressure of various altitudesAbsolute Pressure At Altitudes Above Sea Level (Based on US Standard Atmosphere)
Altitude
0500
Feet In Hg PSIA Feet In Hg PSIA Feet In Hg PSIA
600700800900
100015002000
299229382928291829072897288628332782
147014431438143314281423141813901367
250030003500400045005000550060006500
273126812632258425362489244323982353
134113191292127012451223120011771156
700075008000850090009500
10000
2309226522222180213820982058
1134111210901070105010901010
Pressure Altitude Pressure Altitude Pressure
The horsepower changes as the cube of the speed ratioExample ndash A blower is operating at a speed of 3500 RPM andrequiring 50 horsepower If the speed is reduced to 3000 RPMwhat is the new required horsepower
HP 1 = Original Horsepower (50)HP 2 = New HorsepowerRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
HP 2 = HP 1 x (RPM 2)3= 50 x (3000 )3
= 50 x 630 = 315 horsepowerRPM 1 3500
The above is known as the 1-2-3 rule of blowers
Horsepower vs Specic Gravity amp Ratio of densityThe horsepower varies in direct proportion to the specic gravity(ratio of density of gas to density of air)Example ndash A standard air blower requires a 10 HP motor Whathorsepower is required when this blower is to handle a gaswhose specic gravity is 05
HP = 10 x 05 = 5 horsepower
It is possible that several of the above modications may berequired on one installation Therefore it may be necessary touse various combinations of these formulae
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Orice Flow
Orice Flow CalculationTo determine air ow through an orice
V = CK radic P Q = AV VP = ( V ) 2K
WhereV = V elocity in feet per minute (fpm)C = Orice CoecientK = Constant = 14786 when P is expressed
in In Hg21094 when P is expressedin PSIG4005 when P is expressedin In of Water
(Above constants are based on an air densityof 0075 lbsft 3)
P = Pressure dierential across the oriceQ = Flow rate in cubic feet per minute (CFM)A = T otal orice area expressed in square feetVP = Velocity pressure (units are those of pressure)
Coecient C for Orices UnderVacuum or Pressure Flow
Area of OricesOrice Diameter in Inches
Diameterin Inches Square Inches Square Feet
18 01227 000085316 02761 0001914 04908 0003438 11044 0007612 19634 0013658 30679 0021378 60132 0041710 78539 00545
Orice area (in sq inches) = 25 X π X (orice diameter in inches) 2
Orice area (in sq feet) = Area in sq inches divide 144
ORIFICE PRESSURE DROP AS A FUNCTIONOF FLOW AND ORIFICE AREA (C=65)
c-98 c-92 c-82 c-80
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
c-72 c-65 c-80 c-53
15
30
45
60
75
90
105
120
135
150
20
40
60
80
100
120
140
160
180
20
0 100 200 300Flow Rate SCFM
400 500
500 700 900 1100Flow Rate SCFM
1300 1500
1500 1700 1900 2100Flow Rate SCFM
2300 2500
40
60
80
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Friction Loss Per Foot of Tubing
Friction Loss in Fittings
To calculate friction loss in ttings use chart below This chart will yield equivalentlengths (in feet) of tubing Use this length with graph above to nd friction loss ininches of water column
NOMINAL PIPE SIZE (INCHES) EQUIVALENT TUBING LENGTH (FEET)
90deg EL 45deg EL
1 14 3 151 12 4 2
52 252 12 6 3
47314 0 515 2 616 5 7528 0 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Noise Facts
Loudness Levels of Familiar Noises (Approximate Average Including Ear Nework)
bull OSHA (Occupational Safety amp Health Administration) regulates and monitors in-plant noisebull Allowable noise is a function of dBA level at certain distance over an exposure timebull OSHA regulations state 90 dBA for an 8 hour work period using slow responic setting on meterbull Adding a second noise producer of equal dBA will add 3 dBA to the first dBA readingbull Sound pressure level (SPL) decreases with distance (d)
(SPL) 2 = (SPL) 1 - 20LOG ( d2 )d1
Therefore each doubling of distance results in 6 dBA reduction
Threshold of Painful Feeling
Airplane and Propeller at 10
Ft
Train Passing at High Speed
Riveter at 30 Ft Auto Horn at 20 Ft Pneumatic Drill at 10 FtSubway TrainFire Siren at 75 Ft Noisy Street RailwayNoisy StreetPolice Whistle at 15 Ft Auto at 60 MPH
Very Noisy Restaurant Auto at 40 MPH Average Stenographic Room
Factories Auto at 20 MPHNoise in Pullman (Windows Shut)Noisy OfficeAverage RestaurantDept Store Average Conversation at 3 FtAverage Office Quiet Street Noisy ResidenceQuiet Restaurant Quiet OfficeMuseumAverage School Average Residence Motion Picture Theater Library Reading Rooms AuditoriumsAverage Whisper at 5 Ft Very Quiet Residence
Broadcasting Studio Zero of AIEE Scale 14 Db
Zero of Original Scale 85
Db Threshold of Audibility
1013 130
1012 120
1011 110
1010 100
109 90
108 80
107 70
106 60
105 50
104 40
103 30
102 20
10 10
1 1
Loud
ness
Lev
els
in D
ecib
els
Rel
ativ
e In
tens
ities
(Int
ensi
ty A
bove
Thr
esho
ld =
10
16 w
atts
per
sq
cm
)
A P
P R
O X
I M
A T
E
N O
I S
E
L E
V E
L S
DEAFENING
NOISY
AVERAGE
QUIET
VERY QUIET
SOUND PROOFR OOMS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 91258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Industrial Blower Noise Chart in dBA
dBA at Distance Conversion Chart
Average at 1 meter 4 places around the blower
Mode
Suction
SEMFRDCSL2SL4SL5
60-6264-6576-7869-7272-7876-79
60-6264-6576-7869-7272-7876-79
101202303353404454
65-6767-6965-6772-7373-7476-77
66-6868-7067-6973-7474-7575-76
5135055235556566
80-8177-7882-8380-8182-8385-86
80-8176-7782-8380-8182-8385-86
757808633S7858833
83-8584-8581-8288-8984-8582-84
84-8684-8581-8288-8984-8582-84
SP 99091233SP 13
14SP 15
90-9181-8284-8587-8886-8791-92
90-9184-8684-8590-9186-8791-92
Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure
Mode Mode Mode ModeModel Model Model Model Model
To read use straight edge to connect blower distance and dBA rating A pivot point A will be developed Use straight edge again with new distance and pivot point A to read dBA at new distance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 101258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference
Special Features 0 to 4 letters- see gure 2
Voltage Code up to 3 numbers - see gure 1
Motor Description - see gure 3(TEFC XP Chem and ODP)
Describes which family the unit belongs to 1 to 3 numbers
Option for duplex units onlyP = Parallel congurationS = Series conguration
DR = Domestic RegenerativeEN = EnvironmentalCP = Chemical ProcessHiE = Hi Eciency Motor
Figure 1 Voltage Code
Figure 2 Special Features
This chart explains the nomenclature behind the catalogued blower model names This tool can be used to explainto customers what the letters and numbers mean and will also allow you to become familiar with our model namesThis information should not aect the way orders are placed please continue to use the model names shown inthe catalog and price pages Any special request should be noted on the order
5 230 VAC 60 Hz Single Phase9 115230 VAC 5060 Hz Single Phase33 230 VAC 60 Hz Three Phase58 115230 VAC 60 Hz Single Phase60 200 VAC 5060 Hz Single Phase72 230460 VAC 60 Hz Three Phase75 380 VAC 50 Hz Three Phase86 575 VAC 60 Hz Three Phase89 200-230460 VAC 60 Hz Three Phase91 230460 VAC 5060 Hz Three Phase92 415 VAC 50 Hz Three Phase201 380 VAC 60 Hz
A SPECIAL (not covered by any other letter)BC Blower on pressure onlyD Blower on suction onlyEFGH Vapor recovery service - hydrocarbonJ Nasty Gas face sealKL Lo leak option (lip seal)M Die Cast or muer extensionPQR Chem-Toughtrade constructionS Special manifoldTUV V alveW Rail mounted blowerX Base mounted blowerY Slip on angeZ Package blower coupling driveAA Package blower belt drive simplexBB Package blower drive belt duplexRD Remote driveNT No Tower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference (Contrsquod)
HP Motor ThermalType Protection
HP Motor ThermalType Protection
Figure 3 Motor Description
DEFKMRVWXYADAEAGAKALARASAWAXAYBABBBCBDBEBGBHBKBLBMBPBQBRBXCBCCCD
CJCKCRCSCTCUDCDJDWDXEEEZFAFBFDFEFFFGFHFJFKFLFMFNFQFRFSFUFWFXFYFZGAGBGCGD
RD
25404030201018
11630306015121434255
75101530551412101520305055751015203020
XPTEFC
CHEM TEFCCHEMTEFCCHEM TEFCCHEM TEFC
TEFCTEFCTEFC
XPODP
CHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFC
XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XP
YesNoNoNoNoNoYesYesNoYesNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesYesYesYesYesYesYesYesYesYesYesNo
50505030301515157513131212121010202020757510101015152020152030403414141425
TEFCODPXP
TEFCXP
TEFCODPXP
ODPTEFC
XPTEFC
XPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCXP
ODPODPODPODPTEFCTEFCODPXP
TEFC
NoNoYesNoYesNoYesYesNoNoYesNoNoYesNoYesNoYesYesNoYesNoNoYesNoYesNoYesNoNoNoNoNoNoYesYesNo
CHEM TEFCTEFC
Remote Drive - No MotorGE 115 No
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Corrosion-Resistant and Sanitary Blowers Application Data Sheet
To obtain Application Engineering assistance or a quotation for your specific need please photocopy thisform fill out as much as possible and fax it back to Rotron We look forward to working with you
COMPANY
CONTACT
ADDRESS
ADDRESS
ZIPS TAT EC IT Y
FAXP HONE
GAS CONCENTRATION DESCRIPTIONPercentage Gas Specific Gravity
________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )___ __ _______________ (SG = _______ )
Corrosive Yes No Explosive Yes NoGAS
CLASSIFICATION
AREA
CLASSIFICATION
Corrosive Yes No Explosive Yes No
PERFORMANCE REQUEST Fill in and circle choice
SCFM deg (F C)FLOW INLET TEMPERATURE
PSI (A G) deg (F C)INLET PRESSURE AREA AMBIENT TEMPERATURE
PSI (A G) (Ft M)OUTLET PRESSURE SITE ALTITUDE
___ 100
APPLICATION DESCRIPTION Attach sketch if necessary
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 131258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Warranty Statement
Warranty Statements
1 AMETEK ROTRON DR EN and HiE regenerative direct drive blowers are guaranteed for one full year from the date of installation (limited to 18 months from the date of shipment) to the original purchaser only Should blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related
2 Standard Products - AMETEK ROTRON moisture separators remote drives packaged units CP blowers Nasty GasTM models and special built (EO) products are guaranteed for one full year from the date of shipment for workmanship and material defect to the original purchaser only Should the blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related we will at our option repair or replace the blower
3 Parts Policy - AMETEK ROTRON spare parts and accessories are guaranteed for three months from the date of shipment for workmanship and material defect to the original purchaser onlyIf failure is determined to be workmanship or material defect related we will at our option repair or replace the part
4 Non-Standard Products - Orders for specially-built products will be concidered as non-cancellable Any requested changed by customer after order acceptance will result in additional charges
Corrective Action - A written report will be provided indicating reason(s) for failure with suggestions for corrective action Subsequent customer failures due to abuse misuse misapplica-tion or repeat oense will not be covered AMETEK ROTRON will then notify you or your options Any failed unit that is tampered with by attempting repair or diagnosis will void the warranty unless authorized by the factory
Terms and Conditions - Our warranty covers repairs or replace-ment or regenerative blowers only and will not cover labor for installation outbound and inbound shipping costs accessories or other items not considered integral blower parts Charges may be incurred on products returned for reasons other than failures covered by their appropriate warranty Out-of-warranty product and in warranty product returned for failures deter-mined to be caused by abuse misuse or repeat oense will be subject to an evaluation charge Maximum liability will in no case exceed the value of the product purchased Damage resulting from mishandling during shipping is not covered by this warranty It is the responsibility of the purchaser to le claims with the carrier Other terms and conditions of sale are stated on the back of the order acknowledgement
Hazardous Locations Policy
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous explosive location without proper NEMA motor enclosure AMETEK ROTRON does not recognize sealed blowers as a substitue for explosion-proof motors Sealed units with standard TEFC motors should never be utilized where local state andor federal codes specify the use of explosion-proof equipment
AMETEK ROTRON has a complete line of regenerative blowers with explosion-proof motors Division 1 amp 2 Class I Group D Class II Groups F amp G requirements are met with these standard explosion-proof blowers
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous corrosive environment without the proper surface treatment and sealing options
AMETEK ROTRON has a complete line of Chemical Processing and Nasty GasTM regenerative blowers with Chem-ToughTM stainless steel parts and seals
AMETEK ROTRON oers general application guidance however suitability of the particular blower selection is ultimately the responsibility of the purchaser not the manufacturer of the blower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 14Customer Service Fax +1 2152561338 wwwametekdfscom
AMETEK Inc
AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with annualized sales of more than $25 billion AMETEK has nearly 11000 colleagues working at more than 80 manufacturing facilities and more than 60 sales and service centers in the United States and over 30 other countries around the world
AMETEK DYNAMIC FLUID SOLUTIONS (DFS)
AMETEK Technical amp Industrial Products is a world leader in motors blowers and pumps for mass-transit medical business machine and computer applications It also is a leader in regenerative blowers for pressure and vacuum applications used by broad range of industries
AMETEK supports its customers globally from its manufacturing facilities in Minnesota New York North Carolina Ohio Pennsylvania Italy and China Our brushless DC motors blowers controllers pumps and fans are ideally suited for a wide range of applications including medical instruments robotics pumps compressors offi ce equipment fans machine tools tape drives or any other precise rotary motionair delivery applications
Technical amp Industrial Productsrsquo product line of regenerative blowers for pressure and vacuum applications services the process industrial environmental waste and wastewater industrial industry Typical applications areas include solution agitation and aeration pneumatic conveying part hold-down and pick up part blow off gas and fume extraction and process gas handling
AMETEK Technical amp Industrial Products supplies the solution for unique performance mounting environmental and agency requirements
DYNAMIC FLUID SOLUTIONS
100 East Erie St Kent OH USA 44240USA +1 330-677-3327 - Europe +49 7703 930909 - Asia +86 21
5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Untitled
- Untitled
- Untitled
- Untitled
- Blank Page
- Blank Page
- Blank Page
- Blank Page
-
Table of Contents
F Application Specific Blowers Minispiral F1 Insrument Grade Regenerative Blower
Minispiral MDC F3 Variable Flow Regenerative Blower
Minispiral 1224V HDC F5 Variable Flow Regenerative Blower
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy F7 Variable Flow Regenerative Blower
SPIRAL Simplex SL2 F9 Insrument Grade Regenerative Blower
SPIRAL Duplex SL4 F11 Insrument Grade Regenerative Blower
SPIRAL Duplex SL5 F13 Insrument Grade Regenerative Blower
Nautilair F15 DR 404454505513656 F17 Spa Blowers
DR 10RDNTSS10RDNTHS 10RDNT F19 Remote Drive (Motorless) Blowers
MD 101 Magnetic-Drive F21 Regenerative Blower
GVR313 F23 Regenerative Blower
G Accessories Filtration - Inlet Filter (Single Connection) G1 Filtration - Inline Filter (Dual Connection) G2 Filtration - Filter Silencers (Single Connection) G3 Filtration - Filter Element G4 Filtration - Moisture Separator G5 Measurement - Air Flow Meter G7 Measurement - Digital Flowmeter G9 Noise Reduction - Sound Attenuating Enclosure G10 Noise Reduction - InletOutlet Muffler (Single Connection) G11 Noise Reduction - Inline Muffler (Dual Connection) G12 Protection - Relief Valve - Mechanical G13 Protection - Pressure Regulating Diaphram Valve G14 Protection - Gauges G15 System - Variable Frequency Drive G16 System - Air Knives G17 System - 5 Way 3 Port 2 Position Diverter Valve G19 System - Air Flow Switch G21 Pressure amp Vacuum Arrangements G22 H Motor Blower Options I Application Engineering Basics
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 1 Air-Assisted Breathing
Your own imagination and knowledge are probably the best source of in-plant and on-site applications for ROTRON regenerative blowers This guide will help to pinpoint and stimulate your consideration of the many alternative sources we provide to replace costly and maintenance intensive suction and pressure units and systems The nine major application groups are listed and a cross reference of the most common applications by industry will help you identify both identical and similar applications in your industrial operations
Nose
Part
Blower
Blower
Blower
Blower
Blower
Block
Box
BlowerWork Table
Work
Work
Plenum
PneumaticSuction Cups
Mouth
Flotation Tables
Air Slides Air Tables Turning amp Forming Bars
Air Film SupportAir BagsWeb
General Parts Pick-Up General Parts Hold-Down
Vacuum Manipulator Flotation Tables
Throat
ManufacturingPARP Respiration
MiningPARP Respiration
Application 2 Air-Assisted Inflation or SupportMaterial HandlingAir SlidesAir TablesCarbon Black Car Unloading
Paper ProcessingFlotation TablesForming BarSheet FlutteringTurn Bars
TextileGarment Flotation Tables
Water Pollution ControlPollution ContainmentWaterway Management
Application 3 Air-Assisted Vacuum Pick-Up or Hold-DownManufacturingBag Filling EquipmentCutting TablesPackaging EquipmentVacuum ManipulatorsCorrugated and Paperboard BoxesFlexible Packaging - Paper Plastic Aluminum Foil Textile Packaging and Steel StrappingRigid PackagingBeverage ContainersCosmetic and Toiletry ContainersBlister PacksPharmaceutical PackagingFood PackagingSterile Medical Device PackagingLabelsPressure Sensitive Tape
Paper or Plastics HandlingCutting TablesDiaper Making EquipmentPrinting Presses
TextileGarment Cutting TablesYarn Guiding and TensioningYarn AspirationCarboard Case Erector
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 4 Air amp Gas Sampling Boosting or Circulating
Fluid Bed Regeneration Transmissometer Lens Purging
Natural Gas Boost Air amp Gas Sampling
Combustion Air Boost
Pressurized Cabinet Vacuum Pull-Through Cabinet
Soil Vapor Extraction ampLandll Gas Recovery Vent Header O-Gassing
Fume amp Smoke Removal Digester Gas Collection
Air Pollution ControlAir SamplingAir Stream Release MonitoringFire Prevention Air SamplingFlue Gas Sampling
FoundryCombustion Air Boost
InstrumentationGlove Box PressurizingIncubator Air CirculationWeather Measurement Sampling
ManufacturingCombustion Air BoostNatural Gas BoostOil Demisting
PharmaceuticalClean Room Air CirculationOxygen Generator
Plastics HandlingDesiccant Dryer Bed Regeneration
Application 5 Electronic CoolingInstrumentationEngineMotor CoolingFilm Development System CoolingLamp Bank CoolingSmall Enclosure Cooling
Application 6 Gas Vapor amp Fume Recovery Venting amp TreatmentPharmaceuticalSterilization Gas (ETO) Recovery
ReneriesCentrifuge Venting
Water Pollution ControlDigester Gas Collection
AgriculturalMethane Gas RecoveryChemical ProcessingVent Header O-Gassing
EnvironmentalGasoline Vapor RecoveryLagoon Gas RecoveryLandll Gas RecoveryRadon Gas CollectionSoil Vapor Extraction
FoundryLost Foam O-Gassing
Manufacturing - Plant ServicesCabinet Fume VentingEnvironmental Test Chamber VentingLaser Smoke RemovalWeld Smoke Removal
Natural Gas
Blower
Blower
Blower
Blower
BlowerFilter
Blower
Blower Flame
Digester
Scrubber ChemicalTank
Treatment System
Electronics
Gas
CombustionChamber
BlowerBlower Blower
Light Beam
Lens
Stack
Lens
Natural GasFurnace
Minispiral
Instrument
Blower
Electronics
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Nine Major Blower Application Areas
Application 7 Solid Material Transporting Separation amp CollectionFoundrySand Reclamation
Manufacturing - Waste ControlChip Dust amp Particle RemovalLiquid amp Solvent RemovalPaper Plastic Film amp Textile (Trim) Removal
Material HandlingAir SlidesBlast CleaningDilute Phase ConveyingPneumatic Tube
PackagingBag Filling
Application 8 Parts Blow-Off amp Drying
Application 9 Solution amp Media Agitation amp AerationAquacultureAquarium Fish Farm Hatchery amp Pond Aeration
Groundwater Sparging
ManufacturingConcrete Fluid Bed AerationElectroplating Tank Agitation
Material HandlingFluidized Beds
RecreationCommercial Spa Aeration
Water ManagementBoat Dock amp Dam Face Deicing
Water Pollution ControlUV Tube AgitationWatewater Filter BackwashWastewater Treatment Tank Aeration
ManufacturingConveyor Belt Blow-OElectroplating Fume GuidingElectroplating Parts DryingElectroplating Solution Blow-BackFlat or Irregular Metal Parts DryingWire Drying
Aqueous Precision CleaningAutomotive Parts DryingSemiconductor Board Drying
Food ProcessingBatter Blow-OBottle amp Can DryingLabel DryingSalt Spice amp Flour Blow-O
Dilute Phase Pneumatic Conveying Pneumatic Tube
Paper Plastic Film amp Textile (Trim) Removal
General Parts Blow-O amp Drying Solution Blow-Back
Wastewater Treatment Tank Aeration Groundwater Sparging
Electroplating Tank Aeration Commercial Spa Aeration
Bin Pad amp Fluidized Bed Aeration Boat amp Dock Deicing
General Material Separation amp Collection
PressureBlower
Blower
Blower CollectionChamber
Blower
Blower
Blower
Blower
Blower
ProductBin Aerator
(Air Pads)
Blower
Blower Dock
Water
Hot Tub
Plating Bath
Spargers
Blower
Blower Ground Level
Soil
Water Table
Plating Tank
Air Knife
Hoist
Blower
Air Knife
TubeCarrier
Ejector
Bin
RotaryAirlock
DischargeTo Process
Cyclone
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 A 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Product Dimensional Listing
Blowers Shipping Wt (LBS) Carton Length (In) Width (In) Height (In)
DREN
068 16- 12 12 12
083 18- 12 12 12
101 3047 16 15 14
202 30- 16 15 14
303 4252 16 15 14
353 54- 21 16 16
404 6481 21 16 16
454 6084 21 16 16
505 8292 21 16 16
513 7699 24 12 22
523 112126 24 16 22
555 96- 21 16 16
633 241288 25 18 20
656 110117 24 16 22
6 148167 25 18 20
S7 206- 25 18 20
757 131158 25 18 20
808 285287 34 23 26
833 269297 44 29 37
858 280338 34 23 26
S9 P9 400- 34 23 26
909 373524 34 23 26
979 345533 34 23 26
1233 400- 34 23 26
14 620737 43 28 33
S13 P13 687- 43 28 33
S15 P15 909- 43 28 43
Minispirals (SE212) 2- 8 8 6
Nautilairs (NC33) 18- 16 15 14
Spiral (SL245) 42- 16 15 14
Note Model weight will vary by HP and voltage Refer to individual specication sheets to verify
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 B 1Customer Service Fax +1 2152561338 wwwametekdfscom
Industrial Chemical Processing Blowers AMETEK Dynamic Fluid Solutionsrsquo ROTRON brand has long been a world leader in regenerative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial DR (Domestic Regenerative) blowers include
Rugged cast aluminum housing cover impeller and muffler tower Removable cast iron flanges bolted to a sheet metal manifold TEFC motors on single-ended models ODP motors on all double-ended models Carbon steel shaft and zinc plated hardware Permanently sealed motor bearings for 20000-25000 hours life
Our CP (Chemical Processing Regenerative) blowers include
Chem-ToughTM surface conversion corrosion resistant treatment for aluminum castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Chemical Duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
OUTIN
(2) PLACES
85
671 99
302 100
616
155
029
39
23
641
097
371 94
152
60 DIA
35 DIA
(2) MTG HOLES
162
5876
174
216
9
553
1405
100 OD
8
22
25
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR068DJ9Y
Specification Units 081657
Motor Enclosure - Shaft Mtl - TEFC - CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 16 Kg 73
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 1 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 068
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 13 SCFMbull Maximum pressure 135 IWGbull Maximum vacuum 135 IWGbull Standard motor 18 HP TEFCbull Cast aluminum blower housing impeller amp cover slip-on steel flangesbull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Various horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR068 DR068
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
3
6
9
12
15
18
0
75
149
224
299
373
448
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 2 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
789
200
4
125
8492156
702
328 120833
1783
INOUT
448
113
8
139
685174
037
295
650
749
1651
736
DR083DC9Y - 036862
101(2 MTG HOLES)
397 DIA305
318
(2 P
LACE
S)
94
353
1869NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR083DC9Y
Specification Units 081572
Motor Enclosure - Shaft Mtl - TEFC -CS Horsepower - 18 Voltage AC 115230 Phase - Frequency - Single - 60 Hz Insulation Class - B NEMA Rated Motor Amps Amps (A) 1810-09 Service Factor - 10 Max Blower Amps Amps (A) 118059 Locked Rotor Amps Amps (A) 87435 NEMA Starter Size - 0000
Shipping Weight Lbs 18 Kg 82
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 3 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 083
125 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 24 IWGbull Maximum vacuum 232 IWGbull Standard motor 18 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR083 DR083
0 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
600 34 68 102 136 170 204 238 272 306 340 374
4
8
12
16
20
24
10
20
30
40
50
60
0
50
100
0
50
100
100
0
100
50
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 4 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
0 2 10 12 14 16 18 20 220
4 86
50
0
0 2 10 12 14 16 18 20 220
4 86
Temperature curves are based on standard model
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
115292
211
94
236
131
824 519
37
931
41102 MTG HOLES
312
6579
165741188
106 27
11
1997740
044
1
ROTATIONDIRECTION
1-11 12FEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR101Y9M DR101Y72M DR101Y86M CP101FB91MLR
Specification Units 038936 038937 038938 038225
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 033 033 033 033 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 3417 131206 06 13-1206 Service Factor - 135 125 125 125 Max Blower Amps Amps (A) 3417 13065 04 13065 Locked Rotor Amps Amps (A) 16482 64-5829 42 64-5829 NEMA Starter Size - 0000 00-0000 00 00-0000
Shipping Weight Lbs 30 30 30 30 Kg 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 5 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 101 amp CP 101
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum ow 31 SCFM
bull Maximum vacuum 285 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR101 DR101
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
0 3 6 9 12 15 18 21 24 27 30 33
0 5 10 15 20 25 31 36 41 46 51 56
0
10
20
30
40
50
60
0
25
50
75
100
125
15
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 6 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
1178299
100
0
64 83
1130
963
394100
72
39
127
114
254
518
252 327
286
22
131
283
044
245
45
503153
81220628912263
STANDARDROTATION88
398 DIA10
1 14-11 12 NPSCSTRAIGHT THREAD(2X) CAST IRON FLANGES
(4X)
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR202Y9M DR202Y72M DR202Y86M CP202AE72MLR CP202FA91MLR
Specification Units 080564 080565 080566 038953 038227
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 33 033 033 033 033 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 3417 1206 05 1206 1206 Service Factor - 135 135 135 135 135 Max Blower Amps Amps (A) 5226 154077 057 154077 154077 Locked Rotor Amps Amps (A) 16482 6432 26 6432 6432 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 30 30 30 30 30 Kg 136 136 136 136 136
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 7 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 202 amp CP 202
33 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 40 IWGbull Maximum vacuum 35 IWGbull Standard motor 033 HP TEFC
bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Cast iron (threaded) or face anges for application-specic needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR202 DR202
0 5 10 15 20 25 30 35 40 45 50 55
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 8 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
101(4) MTG HOLES
394
1001
2065
813
L10
0
254
519
132
1
245
64
327
831
113
287
961
2446
45
283
50
127
114
3
72
144
366
112
044
DR303AE9MDR303AE72MDR303AE86M
MODEL L (INMM)1186301211629461193303
891
2263
2 ROTATION DIRECTION
398 DIA
FEMALE THREADBOTH PORTS
1 14 - 11 12 NPSCNOTES
1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR303AE9M DR303AE72M DR303AE86M CP303FA91MLR
Specification Units 038841 038842 038843 080148
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 05 05 05 05 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 6231 13-1206 06 13-1206 Service Factor - 125 125 125 125 Max Blower Amps Amps (A) 63 163083 07 163083 Locked Rotor Amps Amps (A) 21105 10-9246 42 10-9246 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 34 42 42 42 Kg 154 191 191 191
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 9 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 303 amp CP 303
05 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 48 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
DR303 DR303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 10 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
IN
OU
T
L12
22
311
31579
37595
12(4) MTG HOLES
1275324
513
622
115
555
512130
1018
Oslash613
041
10
356
175
292
141
130
90
158 44
156
258BOTH PORTS MODEL
DR353BR9M
DR353BR72M
L (INMM)
1397355
125317
8932268
47 DIA
1 12 - 11 12 NPSC THREAD
ROTATION DIRECTION1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR353BR9M DR353BR72M DR353BR86M CP353BR72MLR CP353FD72MLR
Specification Units 080554 080555 080556 081562 081612
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - CS CHEM TEFC - SS Horsepower - 075 075 075 075 075 Voltage AC 115230 230460 575 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three 60 Hz Three 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 10050 3015 096 3015 3015 Service Factor - 115 125 125 125 125 Max Blower Amps Amps (A) 126 35175 10 35175 35175 Locked Rotor Amps Amps (A) 596298 15276 61 15276 15276 NEMA Starter Size - 0000 0000 00 0000 0000
Shipping Weight Lbs 60 54 54 54 54 Kg 272 245 245 245 245
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 11 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 353 amp CP 353
75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 34 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR353 DR353
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 12 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
375
167
424
119(4) MTG HOLES
2921115
512
893
130
2268
L
4125
046
2816
0
121
830
94
718
182
4
305792 953
12633208
041 89
DR404AL58MDR404AL72MDR404AL86M
MODEL L (INMM)144136601418360213383399
FEMALE THREADBOTH PORTS
1032616
1
1 12 - 11 12 NPSC
47 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA KNOCK-OUT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR404AL58M DR404AL72M DR404AL86M CP404CU72MLR
Specification Units 037407 037406 037408 038233
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 10 10 10 10 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 11457 3015 12 3015 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 145725 4020 14 4020 Locked Rotor Amps Amps (A) 7035 210105 76 210105 NEMA Starter Size - 0000 0000 00 0000
Shipping Weight Lbs 69 64 64 64 Kg 313 29 29 29
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 404 amp CP 404
10 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 58 IWGbull Maximum vacuum 50 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR404 DR404
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
0 10 20 30 40 50 60 70 80 90 100 1100
10
20
30
40
50
60
0
25
50
75
100
125
1500 17 34 51 68 85 102 119 136 153 170 187
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 14 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
IN OUT
475
325 178
1256
15
431
135
L
120
7
418
106
436
111524
133
20
69
175
114
475120
290
51
318
042 11
FEMALE THREAD
(6) MTG HOLES
MODEL
DR454R58MDR454R72M
L (INMM)
14473671331338
83 45
110
319
343
BOTH PORTS
125
10302616
451143
59 DIA
ROTATION DIRECTION
1 12 - 11 12 NPSC
1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR454R58M DR454R72M DR454R86M CP454EZ72MLR
Specification Units 080481 080480 080482 080491
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 115230 230460 575 230460 Phase - Frequency - Single - 5060 Hz Three - 5060 Hz Three - 5060 Hz Three - 5060 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 15678 4623 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 189 5226 21 5226 Locked Rotor Amps Amps (A) 8442 3216 128 3216 NEMA Starter Size - 10 0000 00 0000
Shipping Weight Lbs 73 60 60 60 Kg 331 272 272 272
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 15 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 454 amp CP 454
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 60 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR454 DR454
0 15 30 45 60 75 90 105 120 135 150 1650
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
2240 25 51 76 102 127 153 178 204 229 255 280
15 30 45 60 75 90 105 120 135 150 165
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
00
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 16 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
IN
L
144
3
356
1418
59 DIA
(4) MTG HOLES
475
1030
1170 REF
725
191
37
REF
C B
1359 DIA
15
MODEL DR505AS58M
DR505AS72MDR505AS86MDR505K58MDR505K72M
1563397
1563397
14753741438365170431
L (INMM)
425108437111
437111
463117
463117
B (INMM)564143
525133
564143518131
C (INMM)
518131
FEMALE THREADBOTH PORTS
OUT
45
1143904
3602
366
5
184
2
485
1207
2616
2972
94
1824
3452
1 12 - 11 12 NPSC
ROTATION DIRECTION
1
718 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR505AS58M DR505AS72M DR505AS86M DR505K58M DR505K72M CP505FE72MLR CP505CT72MLR
Specification Units 037542 037543 037544 081882 037551 038239 038237
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS CHEM TEFC - SS Horsepower - 20 20 20 30 30 30 20 Voltage AC 115230 230460 575 115230 230460 230460 230460 Phase - Frequency - Single - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F F NEMA Rated Motor Amps Amps (A) 18291 5427 23 256128 7638 7638 5427 Service Factor - 115 115 115 115 115 115 115 Max Blower Amps Amps (A) 24115 735 30 2814 8844 8844 6834 Locked Rotor Amps Amps (A) 13869 3819 21 19497 8844 8844 3819 NEMA Starter Size - 10 0000 00 150 00 00 0000
Shipping Weight Lbs 97 82 84 91 86 86 82 Kg 44 372 381 413 39 39 372
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 17 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 505 amp CP 505
20 30 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 73 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal muingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
LegendPressureSuction
DR505K72MDR505AS72MDR505K58MDR505AS58M
0 15 30 45 60 75 90 105 120 135 150 16515 30 45 60 75 90 105 120 135 150 165 0
0
50
100
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
50
100
0
50
100
0
50
100
0
37
75
112
149
187
224 2240 25 51 76 102 127 153 178 204 229 255 280
37
75
112
149
187
25 51 76 102 127 153 178 204 229 255 280
0
0
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 18 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
OUTIN
182
1421
160
6
15
408
507
413
88
24
48
128
05
ROTATION
(4) MTG HOLES
106
61
224
122
BOTH PORTSFEMALE THREAD 325
360
937
18
1369346
372
129
1142896
5501397
1388
35261
59 DIA
1 12 - 11 12 NPSC
13
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR513R72 DR513R58 DR513R86 CP513EZ72LR
Specification Units 037217 037209 037773 038241
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS CHEM TEFC -SS Horsepower - 15 15 15 15 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 4623 16884 18 4623 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 525 1995 185 525 Locked Rotor Amps Amps (A) 4321 12060 13 4321 NEMA Starter Size - 0000 10 00 0000
Shipping Weight Lbs 76 95 76 76 Kg 345 431 345 345
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 19 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 513 amp CP 513
15 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 80 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR513 DR513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 20 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
IN OUT
3462
1397
3597
(4) MTG HOLES
564
220
7
1206
2901
3251
FEMALE THREADBOTH PORTS
1363
550
222
869
475
128
1142
L16
12
409
5
419 10
8
47
1194
1416
1443658
150
05
13
1421
3581
695
425
108
523
133
MODELDR523K72DR523K58
1591404119314905
L (INMM)
1 12 - 11 12 NPSC
ROTATION DIRECTION
59 DIA
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (224) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR523K72 DR523K58 DR523K86 CP523CS72LR
Specification Units 037210 037211 037772 038243
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-SS Horsepower - 3 3 3 3 Voltage AC 230460 115230 575 230460 Phase - Frequency - Three-60 hz Single-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 88-8643 27135 34 88-8643 Service Factor - 115 10 10 115 Max Blower Amps Amps (A) 89445 3015 34 89445 Locked Rotor Amps Amps (A) 913457 19698 364 913457 NEMA Starter Size - 00 151 0 00
Shipping Weight Lbs 112 145 112 112 Kg 508 658 508 508
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 21 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 523 amp CP 523
30HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 158 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
LegendPressureSuction
DR523 DR523
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 22 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
MODEL
DR555K72DR555K58
DR555CK72
L (INMM)
1744443
16124091738441
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
1506
1493L
Part Model Number
DR555CK72 DR555CK86 DR555K72 DR555K58 DR555K86 CP555CS72MLR
Specification Units 081100 081102 081099 081098 081101 038245
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC - CS TEFC - CS TEFC - CS CHEM TEFC - SS Horsepower - 40 40 30 30 30 30 Voltage AC 230460 575 230460 115230 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 105 41 7638 256128 3 7638 Service Factor - 115 115 115 10 10 115 Max Blower Amps Amps (A) 1365 42 8844 2814 34 8844 Locked Rotor Amps Amps (A) 9447 80 8844 19497 70 8844 NEMA Starter Size - 10 0 00 151 0 00
Shipping Weight Lbs 113 137 96 91 90 90 Kg 513 621 435 413 408 408
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 23 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 555 amp CP 555
30 40 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 92 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR555CK72DR555K72DR555K58
LegendPressureSuction
DR555CK72DR555K72DR555K58
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 24 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
OUTIN
486
241
1234L
95
165
163
441
5
1463
698 70 200508
40
215
98
50
848334 401016
FEMALE THREADBOTH PORTS
3201016
2032800
MODEL
DR6D89
DR6K72
L (INMM)
18004572
18004572
MUFFLER
2 - 11 12 NPSC
1
562 DIA
ROTATION DIRECTION
419
177 178
850
215
9
102
141
75
58(4) MTG HOLES
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR6D89 DR6D5 DR6D86 DR6K72 CP6FF72LR HiE6D89
Specification Units 027578 036212 027579 027600 038253 038071
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 50 50 50 30 50 50 Voltage AC 230460 230 575 230460 230460 230460 Phase - Frequency - Three - 60 Hz Single - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 11255 21 48 133-126 173-15678 173-15678 Service Factor - 115 10 115 115 115 115 Max Blower Amps Amps (A) 168 25 54 126 15-14874 15-14874 Locked Rotor Amps Amps (A) 165-15576 124 60 10653 165-15576 165-15576 NEMA Starter Size - 11 15 1 10 11 11
Shipping Weight Lbs 148 156 148 132 148 148 Kg 671 708 671 599 671 671
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 25 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 6 amp CP 6
30 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 912 IWGbull Standard motor 50 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
designs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Temperature curves are based on standard model Temperature curves are based on standard model
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR6D89DR6K72DR6D5
LegendPressureSuction
DR6D89DR6K72DR6D5
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
0
50
100
52248 1 pc
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 26 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
NOTES
1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
98 (2X)249
118113000
20
51
322
10502667
818
6101549
6221580
IN OUT
DIRECTIONOFROTATION
103262
189
448
11
4881240
266676 1841
4676
17244 4380
1806 4587
13163343
105
9 26
90
16684237
2 NPSCFEMALE THREADBOTH PORTS
INMM
INCLUDES INLET FILTER
Part Model Number
DR633AY72M DR633AY86M DR633D89M CP633FG72LRM
Specification Units 081691 081693 081689 081695
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 75 75 5 75 Voltage AC 230460 575 208-230460 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F NEMA Rated Motor Amps Amps (A) 23-21105 84 169-15376 23-21105 Service Factor - 115 115 115 115 Max Blower Amps Amps (A) 198-189 79 15-13668 198-189 Locked Rotor Amps Amps (A) 17085 55 165-15576 17085 NEMA Starter Size - 21 1 1-10 21
Shipping Weight Lbs 241 241 223 241 Kg 1093 1093 1012 1093
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 27 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 633 amp CP 633
50 75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 275 IWGbull
bull Maximum vacuum 190 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR633AY72MDR633D89M
LegendPressureSuction
DR633AY72MDR633D89M
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 15 30 45 60 75 90 105 120 135 150 165
0 25 51 76 102 127 153 178 204 229 255 280
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 28 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
414
151
738
25
059
1052 140
1512384
L
556
141
(4X) MTGHOLES
15
15423905
746
190
456
116
Oslash7191826
225 0
6417
3
114202896
492125
572
2 NPSCSTRAIGHT THDSBOTH PORTS
MODEL L (INMM)
DR656CK72XDR656K72X
1750444516004064
12813254
551
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR656CK72X DR656CK86X DR656CK5X DR656K72X DR656K58X CP656CR72XLR
Specification Units 080582 080583 080584 080602 080603 080065
Motor Enclosure - Shaft Mtl - TEFC - CS TEFC - CS TEFC-CS TEFC - CS TEFC - CS CHEM TEFC-SS
Horsepower - 35 35 35 30 30 35Voltage AC 230460 575 230 230460 115230 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Single - 60 Hz Three - 60 Hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 10050 40 18 7437 29145 10050 Service Factor - 115 10 115 115 10 115 Max Blower Amps Amps (A) 11457 52 18 945 278139 11457 Locked Rotor Amps Amps (A) 9447 80 115 5427 17286 9447 NEMA Starter Size - 10 0 1 00 1510 10
Shipping Weight Lbs 110 114 101 103 114 110 Kg 499 517 458 467 517 499
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 29 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperaturs - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
____
Industrial Chemical Processing Blowers
DR 656 amp CP 656
30 35 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull
bull Maximum vacuum 89 IWGbull Standard motor 40 HP TEFCbull
bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
bull Cast iron cover for additional noise resonance
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
LegendPressureSuction
DR656K58XDR656K72XDR656CK72XDR656CK5X
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 30 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
174
444
3
L
504
16
20
571
702
20
281
153389
167
426
063
R03179
CL OF BLOWER9
23
277 575
84
657
1675
128
50
50
71
145
178
ROTATIONDIRECTION
234
70 146 21
MODEL
DR757CK72X
DR757CK86X
DR757D89XDR757D86X
DR757D5MX
1855471
18554711855471
1855471
L (INMM)
5601422
2621031
163414
12733233
1
2 12 NPSCFEMALE THREADSBOTH PORTS
1855471
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (26) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR757CK72X DR757CK86X DR757D89X CP757FF72XLR CP757CR72XLR
Specification Units 081172 081173 081169 081178 081179
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS CHEM TEFC-SS Horsepower - 40 40 50 50 40 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 hz Three - 60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 105 40 126 126 105 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 126 42 15576 15576 126 Locked Rotor Amps Amps (A) 9447 80 19497 19497 9447 NEMA Starter Size - 10 0 10 10 10
Shipping Weight Lbs 131 128 140 140 131 Kg 594 581 635 635 594
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 31 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 757 amp CP 757
40 50 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 83 IWGbull
bull Maximum vacuum 75 IWGbull Standard motor 40 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg 0
C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR757D89XDR757CK72X
LegendPressureSuction
DR757D89XDR757CK72X
0 30 60 90 120 150 180 210 240 270 300 330 0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22451 102 153 204 255 306 357 408 459 510 561
37
75
112
149
187
224
0
0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 32 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
2303
700
1100
200
OUTIN
400
800
494
1150
322
644
1638
588
1778 508
2794
818
101
6
1255
2032
2921
1636
1494
143(4) MTG HOLES
A
A
FEMALE THREADBOTH PORTS
FEMALE THREADBOTH PORTS
SECTION VIEW A-A
585
164
441
76
803204
4161
825
558
147
820
96
563 DIA
2 - 11 12 NPT
2 - 11 12 NPT
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS7X72 DRS7X86
Specification Units 036085 036144
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 19497 78 Service Factor - 115 10 Max Blower Amps Amps (A) 2412 96 Locked Rotor Amps Amps (A) 16683 66 NEMA Starter Size - 11 1
Shipping Weight Lbs 206 206 Kg 934 934
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 33 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S7
75 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 75 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS7
LegendPressureSuction
DRS7
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
25
50
100
125
150
175
0
62
124
249
311
373
436
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 34 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
IN OUT
L
536
421
12
143(8) MTG HOLES
875222
191485
18734757
09
229
359
912
117
529
8
C
35889
177870
FEMALE THREADBOTH PORTS
MODEL
DR808D89MXDR808AY72MX
L (INMM)2223564619314905
17434427
1575
14763749
4001
738187585
21622385685
562 DIA
1
2 12 - 8 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR808AY72MX DR808AY86MX DR808D89MX CP808FG72MXLR HiE808AY72MX
Specification Units 081222 081224 081225 081233 081228
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 75 75 50 75 75 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 17889 72 173-15678 17889 17889 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 108 147 2814 2814 Locked Rotor Amps Amps (A) 12060 60 15276 12060 12060 NEMA Starter Size - 11 1 10 11 11
Shipping Weight Lbs 285 242 195 285 301 Kg 1293 1098 885 1293 1365
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 35 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 808 amp CP 808
50 75 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 75 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR808AY72MXDR808D89MX
LegendPressureSuction
DR808AY72MXDR808D89MX
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 36 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
NOTES
FILTER 515255 INCLUDED1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
MTG HOLEDETAIL
(4X)
20
51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
193
849
23
84213
5241331
ROTA
TION
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
IN OUT
1881 4778
17638 44801
104
426
52
19134859
1050 DIA2667
13983551
2406096
8712212
Part Model Number
DR833BB72M DR833BB86M DR833AY72M DR833AY86M CP833FH72MLR
Specification Units 081702 081704 081699 081701 081710
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 10 10 75 75 10 Voltage AC 230460 575 230460 575 230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Three - 60 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 31-2814 96 23-21105 84 31-2814 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 26-2412 89 212-19296 77 26-2412 Locked Rotor Amps Amps (A) 19095 73 17085 68 19095 NEMA Starter Size - 21 1 21 1 21
Shipping Weight Lbs 269 269 260 260 269 Kg 122 122 1179 1179 122
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 37 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 833 amp CP 833
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 258 IWGbull
bull Maximum vacuum 174 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR833BB72MDR833AY72M
LegendPressureSuction
DR833BB72MDR833AY72M
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 38 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
902
OUT IN
FEMALE THREADBOTH PORTS
355
1860
400
(4) PLACES
19750
200
1016
4724
6811753
13533437
22345674
119
218
155
39
101
825
91
1000
13003302
2563
7091803
831
211
1116
829
67
101
325
73
641626
9992525
1905 X 508
L
MODEL DR858AY72WDR858BB72W
L (INMM)230658572319589
8492156
175950
2413
ROTATION DIRECTION
2 12 - 8 NPSC
75 X 200 SLOT
508
445
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 106 (269) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR858BB72W DR858BB86W DR858AY72W CP858FH72WLR HiE858BB72W
Specification Units 038740 038742 038738 038749 038743
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 10 10 75 10 10 Voltage AC 230460 575 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 2613 105 17889 2613 2613 Service Factor - 115 115 115 115 115 Max Blower Amps Amps (A) 2814 12 2814 2814 2814 Locked Rotor Amps Amps (A) 16281 65 12060 16281 16281 NEMA Starter Size - 21 1 11 21 21
Shipping Weight Lbs 280 280 264 280 280 Kg 127 127 1197 127 127
Model (Base Mount) - DR858BB72X DR858BB86X DR858AY72X Part Number (Base Mount) - 038735 038737 038736
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 39 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 858 amp CP 858
75 100 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 125 IWGbull Maximum vacuum 1048 IWGbull Standard motor 10 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR858BB72WDR858AY72W
LegendPressureSuction
DR858BB72WDR858AY72W
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
25
50
75
100
125
150
0
62
124
187
249
311
373
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 40 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
925
12003048
A
A
816
207
3
218
1 RE
F
1000
7091801
355902
FEMALE THREADBOTH PORTS
(4) PLACES
180
0 D
IA
457
2
400 DIA SLIP-ON1016
L
2349
142
10882764
554
100
025
4
254
756192
SECTION VIEW A-A
MODEL DRP9BM72CDRP9BL72C
L (INMM)3175806533448494
2
1
2 12 - 8 NPSC
ROTATION DIRECTION
56 DIA
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 PRESSURE OUTLET CONNECTION2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP9BM72C DRP9BM72D DRP9BM86C DRP9BM86D DRP9BL72C DRP9BL72D
Specification Units 037033 036275 037040 036276 036512 036513
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP-CS ODP - CS ODP-CS ODP - CS Horsepower - 20 20 20 20 15 15 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Three-60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 49245 49245 20 20 37185 37185 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 6030 6030 222 222 5025 5025 Locked Rotor Amps Amps (A) 306153 306153 115 115 256128 256128 NEMA Starter Size - 32 32 2 2 22 22
Shipping Weight Lbs 400 408 464 408 380 418 Kg 1814 1851 2105 1851 1724 1896
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 41 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P9
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 116 IWGbull Maximum vacuum 95 IWGbull Standard motor 20 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP9BM72CDRP9BL72C
LegendPressureSuction
DRP9BM72CDRP9BL72C
0 80 160 240 320 400 480 560 640 720 800 880 0
0 136 272 408 544 680 816 951 1087 1223 1359 1495
80 160 240 320 400 480 560 640 720 800 880
136 272 408 544 680 816 951 1087 1223 1359 14950
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 42 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
1050 925
1200
223
3048
A
A
218
1
7091801
355902
XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX
FEMALE THREADBOTH PORTS
L
2349
100
554
254
816
207
3
56 (142) DIA (DRS9BL72)
500127756
19051000
254SECTION VIEW A-A
L (INMM)
31758065
33448494
MODEL
DRS9BM72
DRS9BL72
180
457
2
2 12 - 8 NPSC
60 X 135 SLOT(4) (DRS9BM72)
ROTATION DIRECTION
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 137 (348) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS9BM72 DRS9BM86 DRS9BL72
Specification Units 037032 037041 036514
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 20 20 15 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 4824 20 3618 Service Factor - 115 115 10 Max Blower Amps Amps (A) 5628 204 5628 Locked Rotor Amps Amps (A) 288144 115 222111 NEMA Starter Size - 32 2 22
Shipping Weight Lbs 446 446 418 Kg 2023 2023 1896
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 43 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S9
150 200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 206 IWGbull Maximum vacuum 157 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
Temperature curves are based on standard model
LegendPressureSuction
DRS9BL72CDRS9BM72C
LegendPressureSuction
DRS9BL72CDRS9BM72C
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
50
100
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0 40 80 120 160 200 240 280 320 360 400 440
0 67 136 204 272 340 408 475 544 611 680 748
0
35
70
105
140
175
210
0
88
175
263
350
437
525
0
50
100
0
50
100
0
50
100
part 515185
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 44 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
--
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
IN MM
NOTES1 TERMINAL BOX CONNECTOR HOLE 125 (318) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
Part Model Number
DR909BE72W DR909BE86W DR909BB72W DR909BB86W CP909FJ72WLR HiE909BE72W
Specification Units 081737 081739 081738 081744 038632 081735
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 15 15 10 10 15 10 Voltage AC 208-230460 575 230460 575 208-230460 208-230460 Phase - Frequency - Three-60 hz Three-60 hz Three - 60 Hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 415-376188 146 2613 105 415-376188 415-376188 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 4221 17 3417 130 4221 4221 Locked Rotor Amps Amps (A) 318159 164 16281 65 318159 318159 NEMA Starter Size - 22 2 21 1 22 22
Shipping Weight Lbs 400 400 400 400 400 400 Kg 1814 1814 1814 1814 1814 1814
Model (Base Mount) DR909BE72X DR909BE86X DR909BB72X DR909BB86X Part Number (Base Mount) 038622 038626 038623 080183
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 45 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 909 amp CP 909
100 150 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 137 IWGbull Maximum vacuum 106 IWGbull Standard motor 15 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards when properly piped and
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR909BE72WDR909BB72W
LegendPressureSuction
DR909BE72WDR909BB72W
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 46 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
OUT IN
ROTATIONDIRECTION
1303302
952413
L
11252858
193490298
2489
204
518
216
88
428
8B
C D
E
L (INMM)MODEL
DR979BH72W
DR979BE86W
D (INMM) E (INMM)2907366
25386446
25816556
1319335
9882509
9882509
B (INMM) C (INMM)
12253112
10252604
10252604
8382129
8382129
8092055
6881748
6881748
11502921
DR979BE72W
1
4 NPSCPORTS
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 109 DIA (DR979BE72W)
1375 DIA (DR979BH72W)2 75 (191) X 200 (508) 4X MOUNTING SLOTS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR979BH72W DR979BE72W DR979BE86W DR979BH86W CP979FJ72WLR HiE979BE72W
Specification Units 080718 080704 080702 080719 081777
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 20 15 15 20 15 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - H H H H H H NEMA Rated Motor Amps Amps (A) 4623 4422 146 4623 4422 4422 Service Factor - 115 125 115 115 125 125 Max Blower Amps Amps (A) 6030 5226 21 6633 5226 5226 Locked Rotor Amps Amps (A) 294147 290145 93 294147 290145 290145 NEMA Starter Size - 32 22 2 32 22 22
Shipping Weight Lbs 350 300 300 350 300 300 Kg 1588 1361 1361 1588 1361 1361
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 47 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 979 amp CP 979
150 200 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull CE compliant - Declaration of Conformity on filebull Maximum flow 1100 SCFMbull Maximum pressure 80 IWGbull Maximum vacuum 87 IWGbull Standard motor 15 HP TEFCbull Cast aluminum blower housing impeller amp cover cast iron flanges
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Inlet amp outlet internal mufflingbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)bull Chemical duty high efficiency inverter duty or industry-specific designsbull Vairous horsepowers for application-specific needs
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) modelsbull Slip-on or face flanges for application-specific needs
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull Switches - air flow pressure vacuum or temperaturebull External mufflers for additional silencingbull Air knives (used on blow-off applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR979BE72WDR979BH72W
LegendPressureSuction
DR979BE72WDR979BH72W
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1869
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 48 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
200 HP High Pressure Regenerative Blower
NOTES1 TERMINAL BOX CONNECTOR HOLE 138 (35) DIA2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
Part Model Number
DR1233BH72W DR1233BH86W CP1233GD72LRW
Specification Units 081375 081377 081379
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS CHEM TEFC-SS Horsepower - 20 20 20 Voltage AC 208-230460 575 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 51-4623 184 51-4623 Service Factor - 15 115 15 Max Blower Amps Amps (A) 50-4623 178 50-4623 Locked Rotor Amps Amps (A) 397199 159 397199 NEMA Starter Size - 32 2 32
Shipping Weight Lbs 400 400 400 Kg 1814 1814 1814
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 49 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 1233 amp CP 1233
200 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 255 IWGbull Maximum vacuum 175 IWGbull Standard motor 20 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se deg C
Blow
er A
irTe
mp
Rise
deg C
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR1233
LegendPressureSuction
DR1233
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
150
200
250
300
0
125
249
374
498
622
747
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
Inlet Filter part 522948
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 50 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
NOTES1 081801 DRP13BP72C MODEL SHOWN2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
PART NUMBER
081801
113028702
94423976
47211995
43010922
84721514
C
E
122131013
355790348
145436932
95024130
94824079
130533134
57314554
40010160
2050
10462657
177845171
FLEX TUBING (2X)
4rdquo - 8 NPT (2X)FEMALE THREAD
6rdquo - 8 NPSC FEMALE1533886 DEEP
125231788
G
75 X 200 SLOT191 X 508 (4X)
H
ROTATIONDIRECTION
081802
081804
081805
081798
081797
DRP13BP72C
DRP13BP72D
DRP13BP86C
DRP13BP86D
DRP13BM72C
DRP13BM72D
1130287
1130287
1130287
1130287
105526797
105526797
250163525
250163525
250463525
250463525
242661611
242661611
125231788
125231788
125231788
125231788
107727343
107727343
2508
2508
2508
2508
1383505
1383505
MODEL C INMM H INMM G INMM E INMM
INMM
Part Model Number
DRP13BP72C DRP13BP72D DRP13BP86C DRP13BP86D DRP13BM72C DRP13BM72D
Specification Units 081801 081802 081804 081805 081798 081797
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS ODP-CS Horsepower - 30 30 30 30 20 20 Voltage AC 230460 230460 575 575 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 7035 7035 28 28 49245 49245 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 380190 380190 174 174 306153 306153 Max Blower Amps Amps (A) 11055 11055 36 36 6432 6432 NEMA Starter Size - 33 33 3 3 32 32
Shipping Weight Lbs 687 687 687 687 592 592 Kg 3116 3116 3116 3116 2685 2685
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 51 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P13
200 300 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 115 IWGbull Maximum vacuum 103 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP13BP72CDRP13BM72C
LegendPressureSuction
DRP13BP72CDRP13BM72C
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200
0 340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 52 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
944
1130
472
112
8
107743
847
1454
9501
081363
OUT
IN
1233
2736
2398
2870
1199
286
525
04
63621
51
109
2
SECTION VIEW A-A
35579035
197
950
27
3693
274
3462 2413
4241077
3132
204
952
04
BOTHPORTS
1
SLOTS75x200(19x508)(4) PLACES
3
2
NOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4rdquo-8 NPSC FEMALE THREAD BOTH PORTS3 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS5 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING6 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS13BP72 DRS13BP86 DRS13BM72
Specification Units 081800 081803 081799
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 30 30 20 Voltage AC 230460 575 230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three-60 Hz Insulation Class - F F F NEMA Rated Motor Amps Amps (A) 7839 28 49245 Service Factor - 115 115 115 Max Blower Amps Amps (A) 8040 32 70153 Locked Rotor Amps Amps (A) 380190 174 306153 NEMA Starter Size - 33 3 32
Shipping Weight Lbs 646 646 562 Kg 293 293 2549
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 53 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S13
200 300 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 195 IWGbull Maximum vacuum 132 IWGbull Standard motor 30 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS13
LegendPressureSuction
DRS13
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1087 1223 1359 1495
0
35
70
105
140
175
210
0
87
174
261
348
436
523
0
50
100
0
50
100
(part 511569)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 54 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
11001311
128
8
17004318
MODELDR14DW72MW
L (INMM) D (INMM)19850331558014
L
751905
29257430
276
701
0972
2477
300762
2794
17574463
234
659
59
327
2
333
9652451
11572939
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
D
SEE NOTE 1
2332 DIA5923
1531 DIA3889
SEE NOTEOUT IN 1
NOTES1 LIFTING SLOT 100 X 170 (254 X 432)2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DR14DW72MW DR14DW86MW DR14DT72MW DR14BH72MW CP14FK72MWLR HiE14DW72MW
Specification Units 081476 081479 081483 081480 081490 081497
Motor Enclosure - Shaft Mtl - TEFC-CS TEFC-CS TEFC-CS TEFC-CS CHEM TEFC-SS TEFC-CS Horsepower - 30 30 25 20 30 30 Voltage AC 230460 575 230460 230460 230460 230460 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 6633 265 5829 4623 6633 6633 Service Factor - 115 115 115 115 115 115 Max Blower Amps Amps (A) 9045 328 9045 6030 9045 9045 Locked Rotor Amps Amps (A) 430215 172 304152 294147 430215 430215 NEMA Starter Size - 33 3 33 32 33 33
Shipping Weight Lbs 696 694 650 600 696 696 Kg 3157 3148 2948 2722 3157 3157
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 55 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR 14 amp CP 14
200 250 300HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 120 IWGbull Standard motor 30 HP TEFC
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
LegendPressureSuction
DR14DW72MWDR14DT72MWDR14BH72MW
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 56 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
141
411
42
588
A
2404 REF
969
296
4
1562
1250
1034
OUT IN
SECTION VIEW A-A
1238
295
3
10114
233
0 D
IA
121
2 320
1 RE
F
OU
T IN
359
2
149
4
290
1
752
9
2461
6106
3145
3967
3175
2626
750
1
591
8
307
8
813
1
A
1129
1429363
1725
11252858
43822868
39823982714281 DIA
(2 PLACES)
19(4) PLACES
508
300762
1
2
3
75 X 200 SLOTNOTES1 TERMINAL BOX CONNECTOR HOLE 250 (635) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 PRESSURE CONNECTION 6-8 NPSC FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRP15EE72C DRP15EE72D DRP15BQ72C DRP15BQ72D DRP15BQ86C DRP15BQ86D
Specification Units 081499 081629 081501 081500 TBD TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP - CS ODP - CS ODP - CS ODP - CS ODP - CS Horsepower - 60 60 40 40 40 40 Voltage AC 230460 230460 230460 230460 575 575 Phase - Frequency - Three-60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Three - 60 hz Insulation Class - F F F F F F NEMA Rated Motor Amps Amps (A) 14070 14070 9648 9648 384 384 Service Factor - 115 115 115 115 115 115 Locked Rotor Amps Amps (A) 870435 870435 630315 630315 540270 540270 Max Blower Amps Amps (A) 17085 17085 16080 16080 64 64 NEMA Starter Size - 54 54 43 43 3 3
Shipping Weight Lbs 1025 1025 923 923 923 923 Kg 4649 4649 4187 4187 4187 4187
Description - Pressure Mode Suction Mode Pressure Mode Suction Mode Pressure Mode Suction Mode
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 57 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR P15
400 600 HP Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 150 IWGbull Maximum vacuum 115 IWGbull Standard motor 60 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbullbull
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
LegendPressureSuction
DRP15EE72DDRP15BQ72C
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
0
0
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
200 400 600 800 1000 1200 1400 1600 1800 2000 2200
340 680 1019 1359 1699 2039 2379 2718 3058 3398 3738
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 58 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
2469
A
OU
T
IN
IN
OUT
A
SECTION VIEW A-A
972
BOTHPORTS
1
4
2
5
3
1082743
12503175
1563962
600
152
4
286
726
4
1313327
140
355
610
626
92
1343404 104
2642
17254382
28401118
1162946
1293277
3929957
234
594
4
NOTES1 TERMINAL BOX CONNECTOR HOLE 88 (22) DIA2 4-8 NPSC FEMALE THREAD BOTH PORTS3 FOUR MOUNTING SLOTS 75 (19) X 200 (508)4 TWO LIFTING SLOTS 100 (254) X 170 (432)5 LABEL INDICATES ROTATION DIRECTION AND ldquoIN amp OUTrdquo PORT LOCATIONS6 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING7 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
Part Model Number
DRS15BQ72 DRS15BQ86
Specification Units 081502 TBD
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 40 40 Voltage AC 230460 575 Phase - Frequency - Three-60 Hz Three-60 Hz Insulation Class - F F NEMA Rated Motor Amps Amps (A) 9648 384 Service Factor - 115 115 Max Blower Amps Amps (A) 14070 52 Locked Rotor Amps Amps (A) 630315 216 NEMA Starter Size - 43 3
Shipping Weight Lbs 923 923 Kg 4187 4187
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 59 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Industrial Chemical Processing Blowers
DR S15
400 HP High Pressure Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200 IWGbull Maximum ow 925 SCFM
bull Maximum vacuum 1347 IWGbull Standard motor 40 HP ODP
(threaded)bull UL amp CSA approved motor with permanently sealed ball bearingsbull Quiet operation within OSHA standards when properly piped or mued -
1 inlet muer included
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
deg C
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
deg C
LegendPressureSuction
DRS15
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
40
80
120
160
200
240
0
100
200
300
400
500
600
0
50
100
0
50
100Temperature curves are based on standard model
(part 516264)
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS C 60 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers Our environmental EN blowers are designed the same as the DR blowers except added features include
Heavy duty cast aluminum manifold Our spark resistant housing cover impeller muffler tower and manifold are
vacuum impregnated Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less Explosion-proof motors standard and available in a variety of world voltages All metal-to-metal surfaces are sealed with RTV sealant
Various UL explosion-proof listings Consult factory
Environmental (EN) regenerative blowers are also available in our Chemical Processing (CP) configuration
Chem-ToughTM surface conversion corrsion resistant treatment for all castings Teflonreg lip seal in a stainless steel case standard for leakage containment to 25 ccmin or less
Chemical duty motors with 303 stainless steel motor shafts Stainless steel hardware throughout
Nickel plated flanges and muffler retainers
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
7741956
6131557
13753493
8622190
4651181
963
244
6
140
1
312793325
826
650
752 1651
1910
4131049
125
1
553
1 - 11 12 NPSCFEMALE THREADBOTH PORTS
1
ROTATIONDIRECTION
38 (96) DIA2X MTG HOLES
100
355
9
317
8
140
5
254
040
102
NOTES1 TERMINAL BOX CONNECTOR HOLE 75rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN101AG58L EN101AG91L CP101FN58LR CP101FN91LR
Specification Units 038171 038019 080622 038950
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 7437 9045 7437 9045 Locked Rotor Amps Amps (A) 63 1575 63 1575 Service Factor Amps (A) 3819 8945 3819 8945 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 47 47 47 47 Kg 213 213 213 213
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 101 amp CP 101
5 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 25 IWGbull Maximum vacuum 23 IWGbull Standard motor 05 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN101
LegendPressureSuction
EN101
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0 3 6 9 12 15 18 21 24 27 30 33
0 51 102 153 204 255 306 357 408 459 510 561
0
5
10
15
20
25
30
0
125
249
373
498
622
747
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 2Customer Service Fax +1 2152561338 wwwametekdfscomcom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
OUTIN
338 327
575
108
2
859 831
274
8
048
197
406
891
39450
1031
10(4) MTG HOLES
12043058
137
3485
7914
71
698
177
3
961
1090
397 DIA
1
122
2441
1001
2263
1 14 - 11 12 NPSCFEMALE THREADBOTH PORTS
146
12769
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREADgt2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN303AG58L EN303AG91L CP303FN58LR CP303FN91LR
Specification Units 038172 038026 080247 038954
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 5 5 5 5 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 230460 115230 230460 Max Blower Amps Amps (A) 9045 1575 9045 1575 Locked Rotor Amps Amps (A) 7236 16383 7236 16383 Service Factor Amps (A) 3819 89445 3819 89445 Starter Size - 000 0000 000 0000 Thermal Protection - 10 135 10 135 XP Motor Class - Group - Not Required Not Required Not Required Not Required
- I-D I-D I-D I-D
Shipping Weight Lbs 52 52 52 52 Kg 236 236 236 236
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 303 amp CP 303
5 HP Sealed Regenerative wExplosion-Proof motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 50 IWGbull Maximum vacuum 45 IWGbull Standard motor 05 HP explosion-proof
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN303 EN303
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
150
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
25
50
75
100
125
150
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
0 9 17 25 34 42 51 59 68 76 85 93 0 9 17 25 34 42 51 59 68 76 85 93
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor
628
375
492
666
512
893
159
5
112
1692
125
2268
130(4) MTG HOLES
L12
23
311
2
304762 953
11632954
119
718
182
4
2921
044
10132573
EN404AR72MLEN404AR58MLMODEL L (INMM)
1641416815503937
ROTATION DIRECTION
1
47 DIA
115 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN404AR58ML EN404AR72ML CP404FQ58MLR CP404FQ72MLR
Specification Units 038173 038174 080075 038958
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 10 10 10 10 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115230 208-230460 115230 208-230460 Max Blower Amps Amps (A) 114569 3216 114569 3216 Locked Rotor Amps Amps (A) 14472 3618 14472 3618 Service Factor Amps (A) 7236 202101 7236 202101 Starter Size - 000 0000 000 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 81 64 81 64 Kg 367 29 367 29
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 404 amp CP 404
10 HP Sealed Regenerative wExplosion-Proof Motor ATEX model certified
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 52 IWGbull Maximum vacuum 48 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN404
LegendPressureSuction
EN404
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
50
100
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
IN OUT
177
3
488
3175
120
7
698
125
475
4751206
107
4501143
327
831 452
(6) MTG HOLES
3327
178
192
042
135
3
1310
15
1367
2896
2616
538
114 REF
1030
343
7
18704750
1
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN454W58ML EN454W72ML CP454W72MLR CP454FR72MLR
Specification Units 080487 080488 080490 080494
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-CS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 115208-230 230460 230460 230460 Motor Nameplate Amps Amps (A) 1579-75 4623 4523 4623 Max Blower Amps Amps (A) 19109-95 5628 5628 5628 Locked Rotor Amps Amps (A) 96-48 3216 3216 3216 Service Factor - 10 0000 0000 0000 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 90 84 84 84 Kg 408 381 381 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 454 amp CP 454
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 65 IWGbull Maximum vacuum 59 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN454 EN454
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN505AX58ML EN505AX72ML CP505FS58MLR CP505FS72MLR
Specification Units 038177 038178 080655 038962
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 20 20 20 Phase - Frequency - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Voltage AC 115230 230460 115230 230460 Motor Nameplate Amps Amps (A) 2211 5829 2211 5829 Max Blower Amps Amps (A) 2412 6432 2412 6432 Locked Rotor Amps Amps (A) 11256 5628 11256 5628 Service Factor - 10 00 10 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 92 84 92 84 Kg 417 381 417 381
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 505 amp CP 505
20 25 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull Maximum vacuum 70 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN505AX72MLEN505AX58ML
LegendPressureSuction
EN505AX72MLEN505AX58ML
0
50
100
0
50
100
0
50
100
0
50
100
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 77 102 127 153 178 204 229 255 280
0
15
30
45
60
75
90
0
37
75
112
149
187
224
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
OUTIN
442
112340
44
372 550
1364
1387
1397945
3465
(4) MTG HOLES
2248
822
35
569
475
128
1206
140
3251
05
127
1819
14213609
669170
553
15703988
159
2
3523
15
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN513W58L EN513W72L CP513FR58LR CP513FR72LR
Specification Units 038183 038037 038966
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 15 15 15 15 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 115208-230 230460 115208-230 230460 Max Blower Amps Amps (A) 1579-75 4623 1579-75 4623 Inrush Amps Amps (A) 19497-90 5427 19497-90 5427 Service Factor Amps (A) 84-42 3216 84-42 3216 Starter Size - 10 0000 10 0000 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 99 93 99 93 Kg 449 422 449 422
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 513 amp CP 513
15 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 88 IWGbull Maximum vacuum 75 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
LegendPressureSuction
EN513 EN513
0 10 20 30 40 50 60 70 80 90 100 110 0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187 0
0
15
30
45
60
75
90
0
15
30
45
60
75
90
0
37
75
112
149
187
22417 34 51 68 85 102 119 136 153 170 187
37
75
112
149
187
224
0
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
OUTIN
5501397
(4) MTG HOLES
3609
571
1142
128
4751206
145
2901
3251
19194874
6561666
160
140
87 7
16556
1412
15683983
15
1421
575
146
10
5012
7
143
836
53
222
6058
6922
38
ROTATION DIRECTION
59 DIA
FEMALE THREADBOTH PORTS
1 12 - 11 12 NPSC
SEE NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN523M5L EN523M72L CP523FU5LR CP523FU72LR
Specification Units 038223 038184 TBD 038968
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency Voltage - Single-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 230 230460 Max Blower Amps Amps (A) 155-145 7437 155-145 7437 Locked Rotor Amps Amps (A) 181-167 84 181-167 84 Service Factor Amps (A) 94-88 6231 94-88 6231 Starter Size - 1 00 1 00 Thermal Protection - 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D I-D I-D I-D
Shipping Weight Lbs 126 126 150 126 Kg 572 572 68 572
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 523 amp CP 523
30 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 135 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN523 EN523
0
50
100
0
50
100
0
50
100
0
50
100
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
30
60
90
120
150
180
0
75
150
225
300
375
450
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
850
200
400
558
1638
598
800
1150
215
9
508
141
7
101
6
4161
1519
2032
2921
143(4) MTG HOLES
423
916
69
FEMALE THREADBOTH PORTS419
106416
222
825
209
6
7181824
7001778
L
16184110
7751969
095246
6371618
MODEL L (INMM)
562 DIA
2 - 11 12 NPSC
NOTE 1
2055207EN6F72L20845292EN6F5L
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD
POSITIONED AT 12 OrsquoCLOCK2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN6F5L EN6F72L EN6F86L CP6FW5LR CP6FW72LR
Specification Units 038361 038180 038438 TBD 038978
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 50 50 50 50 50 Phase - Frequency Voltage - Single-60 hz Three-60 hz Three-60 hz Single-60 hz Three-60 hz Motor Nameplate Amps AC 230 230460 575 230 230460 Max Blower Amps Amps (A) 195 147 57 195 147 Locked Rotor Amps Amps (A) 23 147 63 23 147 Service Factor Amps (A) 175 15276 38 175 15276 Starter Size - 2 10 0 2 10 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 190 167 167 190 167 Kg 862 757 757 862 757
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 6 amp CP 6
50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 110 IWGbull Maximum vacuum 85 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
Muffler included (part 522948)
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN6F72LEN6F5L
LegendPressureSuction
EN6F72LEN6F5L
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
bull
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
103 262
A C
DIRECTION OF ROTATION
B
ROTA
TIO
N
1171 2974
20 51
322
818
10
59
269
0
IN OUT
622 98 (2X) 1580 610 249 154926611811
6763000 D
1841
2 - 11 12 NPSCFEMALE THREAD
1806 4676 BOTH PORTS
4587
IN MM 512
MTG HOLE 130
591
150 DETAIL
(4X) MODEL A B C DNOTES
1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD EN633 181 1894 167 173 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN EN833 182 1959 180 176
PartModel Number
CP633FY72LREN633BA72LM
081697Specification Units 081698
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1785 1785 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Lbs 288 288Shipping Weight Kg 1306 1306
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 633
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 200195 IWGbull
bull Maximum vacuum 155155 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0
20 40 60 80 100 120 140 160 180 200 220
34 68 102 136 170 204 238 272 306 340
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
414
746
1542
696
538
1052
3917
176
818
95
STRAIGHT THDS2 NPSC
BOTH PORTS
136
7
(4X) MTGHOLES
19374920
151
738
25
551140
05915
1512
1826719
231
587
064
173 492
125
382512813254
114202901
1
STD DIRECTIONOF ROTATION
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN656M5XL EN656M72XL EN656M86XL CP656FU72XLR
Specification Units 080060 080059 080058 080142
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 3 3 3 3 Phase - Frequency - Single-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 208-230 208-230460 575 208-230460 Motor Nameplate Amps Amps (A) 155-145 7437 30 7437 Max Blower Amps Amps (A) 17 105 41 105 Locked Rotor Amps Amps (A) 95-86 5427 216 5427 Service Factor - 1 00 0 00 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 142 117 117 117 Kg 644 531 531 531
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 656 amp CP 656
30 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 75 IWGbull
bull Maximum vacuum 73 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN656M72XLEN656M5XL
LegendPressureSuction
EN656M72XLEN656M5XL
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
15
30
45
60
75
90
0
37
75
112
149
187
224
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
15363901
233517
24
437
9
194
349
35
5931
950
604
2413
130033021534
445175
168
242
72
258
610
18
5731455
10332624
8502159
16644227
1000254
166
9
233
2
663
657
261
918
ROTATIONDIRECTIONOUT IN
2 12 NPSCFEMALE THREADSBOTH PORTS
1
75 X 200 SLOT19508(4) PLACES
INMM
PartModel Number
EN757FL5MWL CP757FX5MWLR
Specification Units 081333 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS CHEM XP-SS Horsepower - 55 55 Phase - Frequency - Single-60 hz Single-60 hz Voltage AC 230 230 Motor Nameplate Amps Amps (A) 217 217 Max Blower Amps Amps (A) 299 299 Locked Rotor Amps Amps (A) 155 155 Service Factor - 1 1 Starter Size - 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D I-D
Shipping Weight Lbs 158 158 Kg 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 21Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
0
0
0
20
40
60
80
100
120
0
50
100
0
50
100
Air Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hour
Legend Pressure Suction
EN757FL5WL
120 40 80 120 160 200 240 260 300 340 380 420
68 136 204 272 340 408 442 510 578 546 714
mba
r
0
50
100
150
200
250
300
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
R031
CL OF BLOWER79
19906316
505
657
261
166
966
3
ROTATIONDIRECTION
L
174
444
3
182
718
MODELEN757M72XLEN757F72XL
L (INMM)1972500921005334
15363886
284
20
508
559
142
715
181
6
16754255
923
234
4
16094087
IN OUT
088
5601422
5731461
10372634
15353899
2 12 NPSCFEMALE THREADSBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
IN
MODELPART NO
NAMEPLATEMOTOR
INMM
PartModel Number
EN757M72XL EN757M86XL EN757F72XL CP757FW72XLR CP757FU72XLR
Specification Units 081176 081177 081174 081180 081181
Motor Enclosure - Shaft - XP-CS XP-CS XP-CS CHEM XP-SS CHEM XP-SS Mtl Horsepower - 30 30 50 50 30 Voltage AC 208-230460 575 208-230460 208-230460 208-230460 Phase - Frequency - Three-60 Hz Three-60 Hz Three - 60 Hz Three-60 Hz Three - 60 Hz Insulation Class - B B B B B NEMA Rated Motor Amps Amps (A) 7236 30 147 147 7236 Service Factor - 10 10 10 10 10 Maximum Blower Amps Amps (A) 105 40 1575 1575 105 Locked Rotor Amps Amps (A) 5447 22 15276 15276 5427 Starter Size - 00 0 11 11 00
Shipping Weight Lbs 158 158 158 158 158 Kg 717 717 717 717 717
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 757 amp CP 757
30 50 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWGbull Maximum vacuum 75 IWGbull Standard motor 50 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN757F72XLEN757M72XL
LegendPressureSuction
EN757F72XLEN757M72XL
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 24Customer Service Fax +1 2152561338 wwwametekdfscom
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options Sealed Regenerative Blower wExplosion-proof Motor
2335 103359311536 2624 573
101
825
86
168
242
72
918
233
2 6
57
261
663
166
9
3901
1
OUT
1455
IN ROTATION DIRECTION
2 12 NPSC FEMALE THREADS BOTH PORTS
850
194
349
35
172
443
79
950175 2159
NOTES 1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
604
2413
1300 33021534
445 IN
MM 75 X 200 SLOT 19508 (4) PLACES 1664
4227
1000 254
PartModel Number
EN757FL5MWL EN808FL5MWL CP757FX5MWLR CP808FX5MWLR
Specification Units 081333 081231 080616
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 55 55 55 55 Phase - Frequency - Single-60 hz Single-60 hz Single-60 hz Single-60 hz Voltage AC 230 230 230 230 Motor Nameplate Amps Amps (A) 217 217 217 217 Max Blower Amps Amps (A) 299 299 299 299 Locked Rotor Amps Amps (A) 155 155 155 155 Service Factor - 1 1 1 1 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Class B - Pilot Class B - Pilot Class B - Pilot XP Motor Class - Group - Duty I-D Duty I-D Duty I-D Duty I-D
Lbs 158 338 158 338Shipping Weight Kg 717 1533 717 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certified to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classification Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
D 25USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom ____
____
Environmental Chemical Processing Blowers
EN 808 Single-Phase and CP Options
Sealed Regenerative Blower wExplosion-proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 80 IWG bull Maximum vacuum 75 IWG bull Standard motor 50 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions 60 Hz
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Bl
ower
Air
Tem
p Ri
se degC
Temperature curves are based on standard model
Legend Pressure Suction
EN808FL5MWL
0
50
100
0 40 80 120 160 200 240 260 300 340 380 420
0 68 136 204 272 340 408 442 510 578 546 714
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 26Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
(8) MTG HOLES
IN OUT
692
850
738 355
1415
709
088
224
111
3
189
1
902
1801
358
909
282
7
480
3
1875
2159
35941758
143
23565984
211
253
7
8752223
8602174 125
318
6751715
117
429
87
185470
3749
15754001
1476
17434427
562 DIA
ROTATIONDIRECTION
FEMALE THREADBOTH PORTS
2 12 - 8 NPSC
NOTE 1
NOTES1 TERMINAL BOX CONNECTOR HOLE 75 NPT CONDUIT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN808BA72MXL EN808BA86MXL CP808FY72MXLR
Specification Units 081229 081230 081234
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 75 75 75 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 Motor Nameplate Amps Amps (A) 18693 74 18693 Max Blower Amps Amps (A) 220110 81 220110 Locked Rotor Amps Amps (A) 12663 56 12663 Service Factor - 11 1 11 Starter Size - 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 287 287 287 Kg 1302 1302 1302
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 27Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 808 amp CP 808 Three-Phase
Sealed Regenerative Blower wExplosion-proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 85 IWGbull Maximum vacuum 90 IWGbull Standard motor 75 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Air knives (used on blow-o applications)bull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
LegendPressureSuction
EN808 EN808
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 28Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
MTG HOLEDETAIL
(4X)
20 51
6101549
622158098 (2X)
249
512130
591
150
118113000
DIRECTIONOFROTATION
322
818
103262
11712974
ROTA
TIO
N
IN OUT
266676
AC
D
B
18414676
105
9 26
90
1806 4587
EN633 181 1894 167 173
MODEL A B C D
EN833 182 1959 180 176
2 - 11 12 NPSCFEMALE THREADBOTH PORTS
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN833BA72LM CP833FY72LRM
Specification Units 081712 081708
Motor Enclosure - Shaft Mtl - XP-CS CHEM XP-SS Horsepower - 75 75 Voltage AC 208-230460 208-230460 Phase - Frequency - Three - 60 Hz Three - 60 Hz Insulation Class - B B NEMA Rated Motor Amps Amps (A) 20-1893 20-1893 Service Factor - 10 10 Max Blower Amps Amps (A) 1995 1995 Locked Rotor Amps Amps (A) 177887 177887 Starter Size - 11 11
Shipping Weight Lbs 297 297 Kg 1347 1347
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 29Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN CP 833
75 HP High Pressure Sealed Regenerative wExplosion-Proof Motor
FEATURES bull Manufactured in the USA - ISO 9001 and NAFTA compliant bull bull Maximum pressure 200195 IWG bull Maximum vacuum 155155 IWG bull Standard motor 75 HP explosion-proof bull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assembly bull Quiet operation within OSHA standards
MOTOR OPTIONS bull International voltage amp frequency (Hz)
BLOWER OPTIONS bull Corrosion resistant surface treatments amp sealing options bull Remote drive (motorless) models
ACCESSORIES bull Flowmeters reading in SCFM bull Filters amp moisture separators bull Pressure gauges vacuum gauges amp relief valves
bull bull bull Variable frequency drive package
Blower Performance at Standard Conditions
Inch
es o
fW
ater m
bar
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
60 Hz
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
50
100
150
200
250
300
0
125
250
375
500
625
750
Temperature curves are based on standard model 0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 30Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
189
5692
1300
817
105
0
218
1
245
675
1096
821
709
1548
1860
481
31758
622
3
554
0
207
526
67
1714
2085
2784
4724
3932
1801
3302
FEMALE THREADBOTH PORTS
191485
13533437
23345928
9462403
9502413
17510752731
MODEL EN858BA72WL
L (INMM)23656007
EN858BD72WL 26006604
L
ROTATION DIRECTION
2 12 NPSC
NOTE 1
OUT IN
445
NOTES1 TERMINAL BOX CONNECTOR HOLE 34rdquo NPT2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN858BD72WL EN858BD86WL EN858BA72WL CP858FZ72WLR
Specification Units 038744 038745 080070 038980
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 100 100 75 100 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 2412 96 18693 2412 Max Blower Amps Amps (A) 3015 116 2613 3015 Locked Rotor Amps Amps (A) 234117 93 12663 234117 Service Factor - 21 1 11 21 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 338 338 326 338 Kg 1533 1533 1479 1533
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 31Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 858 amp CP 858
75 100 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 120 IWGbull
bull Maximum vacuum 95 IWGbull Standard motor 10 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Temperature curves are based on standard model
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model
LegendPressureSuction
EN858D72WLEN858BA72WL
LegendPressureSuction
EN858D72WLEN858BA72WL
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 32Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD 2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
834
2118
IN OUT
EN909BG72WL - 038629
FEMALE THREADBOTH PORTS
9502413
24736281
723
185715994031
137348
259
657
9
202
5
15503698
300643
913
231
9
105
266
7
388 11
1
852159
1075
2731
846
21491163520
9062758
MODEL EN909BG72WL
L(INMM)30177663
EN909DB72WL 23666010
L
ROTATION DIRECTION
4 - 8 NPSC
(4) PLACES75 X 200 SLOT
SEE NOTE1
514
4
INMM
PartModel Number
EN909BG72WL EN909BG86WL EN909BD72WL CP909GA72WLR
Specification Units 081741 081736 081743 038982
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 15 15 10 15 Phase - Frequency - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Voltage AC 230460 575 230460 230460 Motor Nameplate Amps Amps (A) 3618 144 2412 3618 Max Blower Amps Amps (A) 4824 18 3216 4824 Locked Rotor Amps Amps (A) 240120 100 234117 240120 Service Factor - 22 2 21 22 Starter Size - 10 10 10 10 Thermal Protection - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty XP Motor Class - Group - I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 524 524 504 524 Kg 2377 2377 2286 2377
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 33Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 909 amp CP 909
100 150 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 140 IWGbull Maximum vacuum 112 IWGbull Standard motor 15 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN909BG72WLEN909BD72WL
LegendPressureSuction
EN909BG72WLEN909BD72WL
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
50
100
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0 60 120 180 240 300 360 420 480 540 600 660
0 102 204 306 408 510 612 714 816 918 1020 1122
0
25
50
75
100
125
150
0
62
124
187
249
311
373
0
50
100
0
50
100
0
50
100Temperature curves are based on standard model Temperature curves are based on standard model
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 34Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
OUT IN
ROTATIONDIRECTION
4 NPSCPORTS
150 DIA (381)LIFTING LUG
1
9002286
31257938
11382891
5691145
9752477
19254890
8752223 1111
2822
13063317
10372634
25
3264
31
217
755
30
122
531
12
24
762
7
200508
191485
07
619
3NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
EN979BK72WL EN979BK86WL CP979GB72WLR
Specification Units 080724 082277 081778
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS CHEM XP-SS Horsepower - 20 20 20 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 575 230460 Max Blower Amps Amps (A) 4623 184 4623 Locked Rotor Amps Amps (A) 6030 24 6030 Service Factor Amps (A) 334167 118 334167 Starter Size - 32 2 32 Thermal Protection - 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 533 533 533 Kg 2418 2418 2418
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 35Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 979 amp CP 979
200 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 90 IWGbull Maximum vacuum 90 IWGbull Standard motor 20 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p Ri
se degC
Blow
er A
irTe
mp
Rise
degC
Blow
er A
irTe
mp
Rise
degC
Temperature curves are based on standard model Temperature curves are based on standard model
LegendPressureSuction
EN979
LegendPressureSuction
EN979
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
50
100
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 100 200 300 400 500 600 700 800 900 1000 1100
0 170 340 510 680 850 1020 1190 1360 1530 1700 1870
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 36Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
NOTES1 TERMINAL BOX CONNECTOR HOLE 1 14rdquo NPT FEMALE THREAD2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
117
297
4
309
678
638
110027940
16994316426032
1025
3007612
233259239
96424486
44619
OUT IN
1757
96524503
127632410
327
15
243
617
22
86121869
301476556
L
143236373
128
8 153238913
ROTATIONDIRECTION
SLOTS 75 x 200(191 x 508) 4X PLACES
4-8 NPSCFEMALE THREADBOTH PORTS(CAST IRON)
INMM
MODEL LENGTH (INMM)EN14BK72MWL 32128159EN14DX72MWL 311857921
PartModel Number
EN14BK72MWL EN14DX72MWL EN14DX86MWL CP14GB72MWLR CP14GC72MWLR
Specification Units 081485 081486 081487 TBD 081491
Motor Enclosure - Shaft Mtl - Explosion-proof-CS Explosion-proof-CS Explosion-proof-CS CHEM XP-SS CHEM XP-SS Horsepower - 20 30 30 20 30 Phase - Frequency Voltage - Three-60 hz Three-60 hz Three-60 hz Three-60 hz Three-60 hz Motor Nameplate Amps AC 230460 200-230460 575 230460 200-230460 Max Blower Amps Amps (A) 4623 75-6633 265 4623 75-6633 Locked Rotor Amps Amps (A) 6030 8241 33 6030 8241 Service Factor Amps (A) 294147 448224 226 294147 448224 Starter Size - 32 33 3 32 33 Thermal Protection - 10 10 10 10 10 XP Motor Class - Group - Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty Class B - Pilot Duty
- I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG I-D II-FampG
Shipping Weight Lbs 601 737 737 601 737 Kg 2726 3343 3343 2726 3343
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 3 phase motors are factory tested and certied to operate on both 208-230415-460 VAC-3 ph-60 Hz and 190-208380-415 VAC-3 ph-50 Hz Our dual voltage 1 phase motors are factory tested and certied to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage uctuation Special wound motors can be ordered for voltages outside our certied range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
XP Motor Class - Group - See Explosive Atmosphere Classication Chart in Section I
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 37Customer Service Fax +1 2152561338 wwwametekdfscom
____
Environmental Chemical Processing Blowers
EN 14 amp CP 14
200 300 HP Sealed Regenerative wExplosion-Proof Motor
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 144 IWGbull
bull Maximum vacuum 115 IWGbull Standard motor 30 HP explosion-proofbull Cast aluminum blower housing impeller cover amp manifold cast iron
bull UL amp CSA approved motor with permanently sealed ball bearings for explosive gas atmospheres Class I Group D minimum
bull Sealed blower assemblybull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbullbull Variable frequency drive package
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
Inch
es o
f Wat
er
mba
r
Mot
or W
indi
ngTe
mp
Rise
degC
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Blow
er A
irTe
mp
Rise
degC
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
LegendPressureSuction
EN14DX72MWLEN14BK72MWL
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 100 200 300 400 500 600 700 800 900 1000 1100
170 340 510 680 850 1020 1190 1360 1530 1700 18700
0
30
60
90
120
150
180
0
75
150
225
300
375
450
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 D 38Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motor-less) Blowers AMETEK Technical amp Industrial Productsrsquo ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our industrial (_RD) Remote Drive Blowers are motorless models built with DRENCPSL blower features and include
Rugged cast-iron arbor and bearing suspension system Oversized shaft to withstand heavy-duty side loads Precision balanced impellers for low vibration operation High speed versions built with heat treated impellers available
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
MF573RD
NOTES1 CONTACT FACTORY FOR PULLEY OPTIONS2 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING3 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
AIR OUT
ROTATION
AIR IN
C
E
B
A
F
D G
Specification INMM
Model Number Part Number A B C D E F G
MF573RD 026940 363 125 658 175 175 175 356 922 318 1671 445 445 445 904
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
10000 RPM
12000 RPM
14000 RPM
10000 RPM12000 RPM
14000 RPM
10000 RPM
12000 RPM14000 RPM
14000 RPM
10000 RPM
12000 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph
0
4
8
Do not exceed maximum speed shown on each graph
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
SL2RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
ROTATION
FLAT
14-20 UNC - 2B X 444 HOLES EQ SPACED ON 443 DIA
N
B
J
K
E
G
F
T
D
C
H
A
PS
Q
L
4 MTG HOLES
4 MTG HOLES(SAME AS OPPOSITE SIDE)
IN OUT
R
Specification INMM
Model Number Part Number A B C D E F G H J K L M N P Q R S T
SL2RD 026125 733 588 992 145 100 500 175 25 175 141 262 175 496 331 300 992 473 100 1862 1494 252 368 254 127 445 64 445 358 665 445 126 841 762 252 12 254
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
AIR AT 1
00˚C
25˚C50˚C75˚C
6000 RPM5500 RPM
5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
6000 RPM5500 RPM
5000 RPM4500 RPM
4000 RPM3500 RPM3000 RPM2500 RPM
6000 RPM5500 RPM5000 RPM4000 RPM3500 RPM3000 RPM2500 RPM
25˚C50˚C75˚C
AIR AT 100˚C
6000 RPM5500 RPM
5000 RPM4500 RPM4000 RPM3500 RPM3000 RPM2500 RPM
4500 RPM
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
20
40
60
80
100
120
0
25
50
75
100
125
150
Do not exceed maximum speed shown on each graph or 100degC
0
10
20
Do not exceed maximum speed shown on each graph or 100degC
0
10
2015
05
05
15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 404RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR404RDNT 036439 560 115 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 1422 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
EN404RDML 038334 1276 1150 122 200 188 875 156 400 50 500 512 150 617 45 400 1154 3241 2921 3099 508 48 222 396 1016 127 127 130 381 1567 1143 1016 2931
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
75˚CAIR AT 100˚C
50˚C
25˚C
2500 RPM
1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM
25˚C 6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
55004500350025001750
65006500
55004500350025001750
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
50
100
150
200
250
300
Do not exceed maximum speed shown on each graph or 100degC
01
08
70
Do not exceed maximum speed shown on each graph or 100degC
20
04
40
01
08
70
20
04
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 505RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR505RDNT 036437 568 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 1443 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
EN505RDML 038336 1458 1182 1445 200 188 875 156 400 50 531 475 150 731 533 400 1353 3703 3002 367 508 48 222 396 1016 127 1349 1207 381 1857 1354 1016 3437
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000550045003500
2500
1750
75˚C
AIR AT 100˚C
50˚C
25˚C
2500 RPM1750 RPM
5500 RPM
6500 RPM
4500 RPM
3500 RPM25˚C
6500 RPM
5500 RPM4500 RPM
3500 RPM
2500 RPM1750 RPM
AIR AT 100˚C
75˚C
50˚C
60005500
450035002500
1750
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
0 25 50 75 100 125 150 175 200 225 250 275
0 42 85 127 170 212 255 297 340 382 425 467
0
30
60
90
120
150
180
0
75
149
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC
15
20
10
Do not exceed maximum speed shown on each graph or 100degC
40
08 04
15
20
1040
08 04
Air Flow Rate - SCFM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 513RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR513RDNT 038076 607 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 1542 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
EN513RDL 038341 1190 1366 1612 200 188 875 156 516 400 529 475 150 731 645 400 1421 3023 347 4094 508 48 222 396 131 1016 1344 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM
2500 RPM
100˚C75˚C
50˚C
25˚C
60005500
450035002500
60005500
450035002500
2500 RPM
6000 RPM
5500 RPM
3500 RPM
100˚C75˚C
50˚C
25˚C
4500 RPM
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374
0
30
60
90
120
150
180
0
75
150
224
299
373
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
4
8
0
4
8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 523RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR523RDNT 037223 796 138 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 2022 3505 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
EN523RDL 038342 138 1555 1612 200 188 875 156 516 400 718 475 150 731 645 400 1421 3505 395 4094 508 48 222 396 131 1016 1824 1207 381 1857 1638 1016 3609
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
25˚C
AIR AT 50˚C
45003500250017505500
6000
5500 RPM6000 RPM
25˚C4500 RPM
3500 RPM2500 RPM
1750 RPM
5500 RPM6000 RPM
4500350025001750
55006000
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 230 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
0 15 30 45 60 75 90 105 120 135 150 165
0 26 51 76 102 127 153 178 204 229 255 280
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
8
16
0
8
16
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 6Customer Service Fax +1 2152561338 wwwametekdfscom
Dual muers provided in place of muer tower
____
Remote Drive (Motorless) Blowers
DRENCP 6RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR6RDNT 036185 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
EN6RDL 038343 585 1500 1634 362 25 100 175 505 450 610 650 200 819 56 450 1634 1486 381 415 919 64 254 445 128 1143 1549 1651 508 208 1422 1143 415
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM1750 RPM
AIR AT 100˚C
50˚C
25˚C
55004500350025001750
2500 RPM 1750 RPM
2500 RPM
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
550045003500
25001750
75˚C
25˚C
50˚C
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 30 60 90 120 150 180 210 240 270 300 330
0 51 102 153 204 255 306 357 408 459 510 561
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 656RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR656RDNT 080610 735 1244 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 1867 3160 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
EN656RDL 080061 1512 146 1517 200 188 875 156 50 400 583 492 200 746 551 400 1542 385 3708 3853 508 48 222 396 127 1016 1481 125 508 1895 140 1016 3917
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
6000 RPM
5500 RPM
4500 RPM
3500 RPM1750 RPM
100˚C
50˚C
25˚C
600055004500
350025001750
2500 RPM
1750 RPM
2500 RPM
6000 RPM
5500 RPM
4500 RPM
3500 RPM
100˚C
50˚C
600055004500
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
15
30
0
15
30
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 8Customer Service Fax +1 2152561338 wwwametekdfscom
Remote Drive (Motorless) Blowers
DRENCP 757RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR757RDNT 081847 667 1506 1725 362 25 100 175 505 450 619 644 250 922 640 450 1611 1694 3825 4382 919 64 254 445 128 1143 1572 1636 635 2342 1626 1143 4092
EN757RDML 081848 1506 2023 1725 362 25 100 175 450 505 619 644 250 922 640 450 1611 3825 5138 4382 919 64 254 445 1143 128 1572 1636 635 2342 1626 1143 4092
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
5500 RPM
4500 RPM
3500 RPM
AIR AT 100˚C
75˚C
50˚C
5500
450035002500
2500 RPM2500 RPM
5500 RPM
4500 RPM
3500 RPM
5500450035002500
75˚C
50˚C
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
AIR AT 100˚C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 858RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR858RDNT 036413 851 1930 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 2162 4902 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
EN858RDL 038746 1930 2222 2086 350 313 138 200 641 500 949 709 250 1156 816 500 186 4902 5644 5298 889 8 351 508 163 127 241 1801 635 2936 2073 127 4724
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4000 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4000
350025001750
75˚C
50˚C25˚C
AIR AT 100˚C
25˚C
4000 RPM
3500 RPM
2500 RPM1750 RPM
4000
350025001750
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
10
20
0
10
20
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 909RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR909RDNT 081962 853 228 2322 350 500 1375 200 765 500 970 834 301 1297 902 500 198 2167 581 5898 889 127 349 508 194 127 2464 2118 765 3294 2291 127 5029
EN909RDL 081742 228 2451 2322 350 500 1375 200 765 500 970 834 400 1297 902 500 198
5791 6226 5898 889 127 349 508 194 127 2464 2118 1016 3294 2291 127 5029
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
4500 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
4500350025001750
75˚C
50˚C
AIR AT 100˚C
4500 RPM
3500 RPM2500 RPM1750 RPM
4500350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 979RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR979RDNT 080760 105 235 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 2667 5969 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
EN979RDL 080761 235 2517 1978 300 50 188 275 765 675 117 976 400 1015 663 755 1925 5969 6393 5024 762 127 478 699 194 1715 2972 2479 1016 2578 1684 1918 489
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
3700
350025001750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM2500 RPM
1750 RPM
37003500
25001750
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 120 240 360 480 600 720 840 960 1080 1200 1320
0 204 408 612 816 1020 1224 1428 1632 1835 2039 2243
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
20
40
0
20
40
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 1233RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING 2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 FILTER 515256 1PIECE
ROTATION
J +- 12
A
Q +- 12E
G +- 25
D
SEEDETAIL AA
DETAIL AA
C +- 06
236599
03910
B
(4X) F
(4X) R
(2X) H
(2X) T
OUTINK +- 12
L +- 12
M +- 25
N +- 25
(2X) PNPSC THD
Specification
Model Number Part Number A B C D E F G J H K L M N P Q R T
DR1233RD 081853 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 669 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 1699 236 348
EN1233RDL 081854 1496 150 236 945 1280 551 2822 1634 043 315 1181 2205 2047 400 689 093 137 380 381 599 240 3251 14 7168 415 109 80 300 5601 5199 1016 175 236 348
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3500 RPM
2850 RPM
AIR AT 100˚C
50˚C4000 RPM
4300 RPM
40003500
2850
4500400035002850
4300
3500 RPM
2850 RPM
4000 RPM
4500 RPM
75˚C
AIR AT 100˚C
50˚C
75˚C
80 120 160 200 240 280 320 360 400 440 480 520
136 204 272 340 406 476 544 612 680 748 846 884
0
50
100
150
200
250
300
0
100
199
298
398
498
598
0 40 80 120 160 200 240 280 320 360 400 440
0 68 136 204 272 340 408 476 544 612 680 748
0
40
80
120
160
200
240
0
100
199
298
398
498
598
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
5
15
25
5
15
25
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS E 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Remote Drive (Motorless) Blowers
DRENCP 14RD
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
J TYP
DR MODELS EN MODELS DREN MODELS
K
C
A
B
F
G
P
NOUT IN
Q
R
L
ROTATION
M NPSC
DE KEY
H DIA TYP4 MTG HOLES J TYPK
C
A
B
F
G
D E KEY
H DIA TYP4 MTG HOLES
Specification INMM
Model Number Part Number A B C D E F G J H K L M N P Q R
DR14RDNT 081475 987 2224 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 2507 5649 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
EN14RDL 081488 2224 3014 2654 400 50 1875 275 765 675 1024 969 400 1550 1141 755 2332 5649 7656 6741 1016 127 476 699 194 1715 2601 2461 1016 3937 2898 1918 5923
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erIn
put
Hor
sepo
wer
3700 RPM
3500 RPM
2500 RPM
AIR AT 100˚C
75˚C
50˚C
1750 RPM
370035002500
1750
75˚C
50˚C
AIR AT 100˚C
3700 RPM3500 RPM
2500 RPM1750 RPM
3700
350025001750
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
0 80 160 240 320 400 480 560 640 720 800 880
0 136 272 408 544 680 816 952 1088 1224 1360 1496
0
30
60
90
120
150
180
0
75
150
224
299
374
448
Do not exceed maximum speed shown on each graph or 100degC Do not exceed maximum speed shown on each graph or 100degC
0
30
60
0
30
60
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 E 14Customer Service Fax +1 2152561338 wwwametekdfscom
Application Specific Regenerative Blowers Specialty blowers for Commercial Spa High Temperature Natural Gas and Gasoline Vapor Recovery applications
Our industrial NC (NautilairTM Centraxial) blowers include Fiberglass or aluminum housing Aluminum impellers Permanently sealed bearings for 50000 hours life
Our instrument grade and variable flow SE (MinispiralTM Regenerative) blowers include AC and DC versions available for world voltages and maximum flow variability Glass filled molded phenolic impeller aluminum and phenolic case 30000 hour bearing life Small size and lightweight construction
Quiet to NC-47 office equipment standards
Our instrument grade SL (Spiral Regenerative) blowers include Rugged diecast aluminum housing endbells and impellers
Compact size with encased muffler for maximum noise reduction Low amp draw with highly efficient motor
Permanently sealed bearings for 40000 hours life Hermetically sealed models designed for glovebox use
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
111
8032
180 REF
813
4572
44
REF
TYP
411 DIA1044165
4191
Oslash224 DIA
569
210
533
4
416
REF
105
66
212 DIA
1
2
OUT
IN
INMM
PartModel Number
SE2B21 SE62B21 SE2B21A
Specification Units 081901 037395 080694
Phase - Frequency - Single-5060 Hz - Single-5060 Hz Voltage AC 110115 24 110115 RPM RPM 28503400 28503400 28503400 Insulation Class - B B B Full - Load Amps Amps (A) 1714 - 1714 Locked Rotor Amps Amps (A) 1715 - 1715
Shipping Weight Lbs 19 19 19 Kg 09 09 09
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
2 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral
Insrument Grade Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L mdashdb
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Maximum vacuum 35 IWGbull Maximum ambient 40degC
bull Shaded pole motor with ball bearings
bull B10 bearing life 30000 hoursbull Weight 11 lb (05 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONSbull Sealed unitsbull International voltage and frequency (Hz)
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
40
00
10 20 30 40
0 17 34 51 68
30
20
10
100
0
75
50
25
LegendPressureSuction
Minispiral
LegendPressureSuction
Minispiral
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
2 leads 20 gaTFE coveredUL style 1180 (12 long stripped 50)
154
175 203
350
406
67
09
TYP
25
REF
1702
4445 5156
889
10312
635
229
391
2
(2) MTG HOLES538
142
2
190
5
56
75
OD
TYP
113
531346
28768 MAX1727
44
REF
TYP
111
8
032813
180 REF4572
411 DIA1044
1654191
Oslash224 DIA
569
210
533
4
416
REF
10
566
212 DIA
2
OUT
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12V21 SE24V21
Specification Units 037433 037434
Voltage Range VDC 9-15 24-32 RPM RPM 3600-6000 5500-6800 Insulation Class - B B Full - Load Amps Amps (A) 050-10 06-09
Weight Lbs 086 086 Kg 04 04
WARNING ndash ON MDC MODELEXCEEDING 10 AMP MAY DAMAGE CIRCUIT BOARD
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral MDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 70103 IWG (1532 volts)bull Maximum vacuum 70103 IWG (1532 volts)bull Maximum ambient 40degC
amp impellerbull Shaded pole motor with ball bearings
bull B10 bearing life 20000 - 30000 hoursbull Weight 086 lbs (039 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed control
Blower Performance at Standard Conditions12 V-MDC 24 V-MDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
110
0 10 20 30 40 50 60 70 80
100
90
80
70
60
50
40
30
20
10
15 V-MDC
12 V-MDC
9 V-MDC
32 V-MDC
26 V-MDC
24 V-MDC
LegendPressureSuction
Minispiral MDC
LegendPressureSuction
Minispiral MDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
BOTH PORTS
057
OD
145
114290
199505
217
552
226
574
116295
02564063
160
092234
054137
083211 0
75 O
D19
1
Oslash1
8346
5
119302
282716
066168
350889
421
106
9
Oslash 4201067
211
536
186
472
057
145
044
112
165419
067170
4071034
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 12
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21 SE24RE21
Specification Units 081548 080847
Voltage Range VDC 75-15 24-32 RPM RPM 4400-8750 4400-8750 Insulation Class - B B Full - Load Amps Amps (A) 12-25 12-16
Weight Lbs 10 10 Kg 05 05
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 1224V HDC
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOUN
D PO
WER
LEVE
L db
(re
10-1
2 Wat
ts)
OCTAVE BAND CENTER FREQUENCY Hz
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliantbull 12 VDC operation 75-15 VDCbull 24 VDC operation 15-32 VDC
bull Maximum pressure 207 IWG (15)bull Maximum vacuum 207 IWG (15)bull Maximum ambient 40degC
amp impellerbull Brushless DC motor with integrated control electronics
bull Stainless steel ball bearings permanently lubricated for B10 bearing life 20000 - 30000 hours
bull Weight 19 lbs (086 kg)bull Envelope size 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull International voltage and frequency (Hz)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
220 17 34 51 68 85 102 119 136 153
0 1 2 3 4 5 6 7 8 9
20
18
16
14
12
10
8
6
4
2
55
50
45
40
35
30
25
20
15
10
5
15 V-HDC
12 V-HDC
9 V-HDC75 V-HDCLOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
BOTH PORTS
056
ID14
2
106269
192488
217
552
224
569
130330
02564063
160
092234
053135
080203 0
75 O
D19
1 T
YP
Oslash1
750
444
119302
272691
066168
350889
416
REF
10
69
Oslash 4111044
210
5331
8547
00
5614
20
4210
7 R
EF
T
YP
165419
067170
4061031
20 GA TFE COVEREDUL STYLE 1180
14 LONG STRIPPED 14
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SE12RE21A
Specification Units 081881
RPM RPM 7397 - 13205 Voltage Range VDC 75 - 15 Insulation Class - B Full - Load Amps Amps (A) 27 - 62
Weight Lbs 25 Kg 11
WARNING ndash ON HDC MODELMOTOR IS NOT POLARITY PROTECTED CHECK POLARITY CAREFULLY BEFORE ENERGIZING BLOWER
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Minispiral 12V HDC Extra Flow Extra Wide Fat Boy
Variable Flow Regenerative Blower
60
50
40
30
50
40
30
2063 125 250 500 1000 2000 4000 8000
SOU
ND
PO
WER
LEV
EL
db (r
e 10
-12 W
atts
)
OCTAVE BAND CENTER FREQUENCY Hz
EQU
IVA
LEN
T SO
UN
D P
RES
SUR
E LE
VEL
db (r
e 0
0002
mic
roba
r)3
FEET
(09
1 M
ETER
S) F
RO
M N
OIS
E SO
UR
CE
50
40
30
NC
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 26 IWG (15)bull Maximum vacuum 26 IWG (15)bull Maximum ambient 40degC
bull Brushless DC motor with integrated control electronicsbull Stainless steel ball bearings permanently lubricated for B10 bearing life
20000 - 30000 hoursbull Weight 19 lbs (086 kg)bull Compact high performance design 418 x 183 inches (1062 x 465 mm)
OPTIONS
bull Sealed blowers for contamination controlbull Electronic speed controlbull Low voltage optionbull Speed sensing output (FPS)
Blower Performance at Standard ConditionsMinispiral HDC
Inch
es o
f Wat
er
mba
r
Air Flow Rate - SCFM
Air Flow Rate - m3hour
24
260 17 34 51 68 85 102 119 136 153 170 187 204 221
0 1 2 3 4 5 6 7 8 9 10 11 12 13
22
20
18
16
14
12
10
8
6
4
2
0
50
55
60
65
45
40
35
30
25
20
15
10
5
0
15 V-HDC
12 V-HDC
75 V-HDC
LOWVOLTAGEOPERATION
LegendPressureSuction
Minispiral HDC
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
OUT IN
841
666
412
104
7
445
734
742142
175
OD
331
162
412
587
292
289
3091
1991
100
120 175
254
305 445
1217
300 TYP762
784
1491
25 -20 UNC -2B X 31 DEEP(4 MOUNTING HOLES EACH END)
997
498
263
160
ID
253
2
126
2
406
229582
OPTIONAL OUTLET TRIMMER
OPTIONAL INLET TRIMMER
12 CONDUIT HOLE (1) EACH END
56
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL2P2 SL2P52 SL2P90
Specification Units 036000 036013 036018
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS ODP-CS Horsepower - 5 5 5 Voltage AC 115 208-230 380460 Phase - Frequency - Single-5060 Hz Single 60 Hz Three-5060 Hz Insulation Class - B B B Full - Load Amps Amps (A) 245360 95154 3441 Service Factor - 10 10 10 Locked Rotor Amps NEMA Amps (A) 100 43 19 Starter Size - 0000 0000 0000
Shipping Weight Lbs 27 27 27 Kg 122 122 122
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 9Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Simplex SL2
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 32 IWGbull Maximum vacuum 313 IWGbull Standard motor 05 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL2 Spiral SL2
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
0 6 12 18 24 30 36 42 48 54 60 66
0 10 20 31 41 51 61 71 82 92 102 112
0
6
12
18
24
30
36
0
15
30
45
60
75
90
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
656 MAX1666
7211831
12rdquo CONDUIT HOLE(1) EACH END
IN
OUT
1524600
130
3 M
AX
331
997
253
2
300 TYP762
924
5761463
2347
412
104
7
412
162
138351
292
287729
317805
25-20 UNC-2B X 31 DEEP(6) MOUNTING HOLES EACH END742
160
ID
175
OD
445
406
666
262
989
DIA
251
2
456 MAX1158
CAPACITORS ON SINGLEPHASE MODELS ONLY
PartModel Number
SL4P2 SL4P52
Specification Units 036009 036027
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 370380 229220 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL4
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 60 IWGbull Maximum vacuum 558 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL4 Spiral SL4
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
0 8 16 24 32 40 48 56 64 72 80 88
0 14 27 41 54 68 82 95 109 122 136 150
0
10
20
30
40
50
60
0
25
50
75
100
125
150
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
IN
OUT
762
1831
331
805729
742351
412
666
PHASE MODELS ONLY
(6) MOUNTING HOLES EACH END
(1) EACH END
6001524
1666656 MAX
721
130
3 M
AX
300 TYP
412 162
175
OD
138 292
287 317
104
7
445
456 MAX1158
262997
253
2
9242347
5761463
160
ID
40
6
989
DIA
25
12
CAPACITORS ON SINGLE
25-20 UNC-2B X 31 DEEP
12 CONDUIT HOLE
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
PartModel Number
SL5P2 SL5P52
Specification Units 036010 036261
Motor Enclosure - Shaft Mtl - ODP-CS ODP-CS Horsepower - 75 75 Voltage AC 115 208-230 Phase - Frequency - Single-5060 Hz Single 60 Hz Insulation Class - B B Full - Load Amps Amps (A) 458675 185255 Service Factor - 10 10 Locked Rotor Amps NEMA Amps (A) 140 70 Starter Size - 0000 0000
Shipping Weight Lbs 42 42 Kg 191 191
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 13Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
SPIRAL Duplex SL5
Insrument Grade Regenerative Blower
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 31 IWGbull Maximum vacuum 313 IWGbull Standard motor 075 HP ODP
bull Motor with permanently sealed ball bearingsbullbull Quiet operation within OSHA standards bull Thermal overload protection
OPTIONSbull International voltage amp frequency (Hz)bull Hermetically sealedbull UL amp CSA approved motorbull Remote drive (motorless) model
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
LegendPressureSuction
Spiral SL5 Spiral SL5
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
Temperature curves are based on standard model0
50
100
0
50
100Temperature curves are based on standard model
0
50
100
0
50
100
0
15
30
45
60
75
90
0 10 20 30 40 50 60 70 80 90 100 110
0 17 34 51 68 85 102 119 136 153 170 187
0
6
12
18
24
30
36
0
15
30
45
60
75
90
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
AB
B
CX
W
R S
L
F
PU
M N O11
3 (2
869
6)
J
(4X) MTG HOLES028 DIA
KG
VZ
T
250 (6350)AA
Oslash40HOLE (4X)
175 (4445)35 (8890)
TEFC MODEL
D (R
EF)
538
(136
65)
E
Y
Oslash5
19 (1
318
3)
495 (1257)
495 (1257)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
CX
W
Oslash769 (19528)
R S
L
P (DIA INLET)F
U
M N O
J
(4X) MTG HOLES028 DIA
KG
VZ
H (TYP)
T253 (6431)
HOLES FOR ELECTRICAL CONNECTIONS
14-20 UNC-2B X 50 DP(4) MTG HOLES EQUALLYSPACED ON A 3625 DIA BC
14-20 UNC-2B X 50 DP(4) MTG HOLES
175 (4445)350 (8890)
STANDARD MODEL
D3
49 (8
875
)
123
(31
35)
E
Y
150 (3810)
KNOCKOUT FORAIRFLOW SWITCH(BOTH SIDES)
A
B
C
D
E
F
G
H
J
K
L
M
N
O
P
R
S
T
U
V
W
X
Y
Z
AA
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
197(50)
278(706)
726(1844)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
NC33AG58(XP)
NC33AE9(TEFC)
NC33A(STD)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
420(1067)
278(706)
1394(3541)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)
---
1155(2932)
607(1542)
0495(126)
604(1534)
1076(2733)
519(1318)
425(108)
025(64)
175(445)
510(1295)
313(795)
475(1207)
559(142)
590(1499)
60(1524)
352(894)
278(706)
1335(3391)
238(605)
213(541)
296(752)
084(213)
40(1016)
25(635)713
(1811)
PartModel Number
NC33A2G NC33A3G NC33A33G NC33AE9 NC33AG58
Specification Units 037791 037792 037793 080114 080113
Phase - Frequency - Single-5060 Hz Single-5060 Hz Three-5060 Hz Single-5060 Hz Single-5060 Hz Voltage AC 115 220230 208-230 115230 115230 RPM on 5060 Hz - 29003500 29003500 29003500 29003500 29003500 Insulation Class - B B B F F Full - Load Amps Amps (A) 344384 147182 110118 6030 44 Locked Rotor Amps Amps (A) 825 40 50 21105 3819
Shipping Weight Lbs 18 18 18 28 30 Kg 82 82 82 127 136
Motor Enclosure - Standard Standard Standard TEFC XP
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
Nautilair
80
70
60
50
40
90
80
70
60
50
EQUI
VALE
NT S
OUND
PRE
SSUR
E LE
VEL ndash
db (r
e 0
0002
micr
obar
)3
FEET
(09
1 M
ETER
S) F
ROM
NOI
SE S
OURC
E
SOUN
D PO
WER
LEVE
L ndashdb
(re
10
Wat
ts)
2075
75150
150300
300600
6001200
12002400
24004800
480010000
OCTAVE BAND CENTER FREQUENCY Hz
-12
NC33
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 35 IWGbull Thermoset plastic blower housing with aluminum impellerbull Permanently seal ball bearings in motor - L10 bearing life 50000 hoursbull Quiet operation within OSHA standardsbull Shipping weight 18 lbs (82 kg) for standard model
28 lbs (127 kg) for TEFC model30 lbs (136 kg) for XP model
bull Designed for UL and CSAbull Automatic thermal overload protection on standard motor enclosures
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
LegendPressureSuction
LegendPressureSuction
NC33 NC33
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
0 50 100 150 200 250 300 350 400 450 500 550
0 85 170 255 340 425 510 595 680 765 850 935
0
1
2
3
4
5
6
0
25
50
75
100
125
150
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
G650
165
1
B
C
E042107
1021259
LF
I HA
J
D
(4) MTGHOLES
THREAD
THREAD
MODEL
DR404AQ58M
DR454V58
DR505AW58M
DR513V58
DR656K58X
A (INMM) B (INMM) C (INMM) D (INMM) E (INMM) F (INMM) G (INMM) H (INMM) I (INMM) J (INMM) K (INMM) L (INMM)
8932268 1012257
4751207
4751207 192488 6281595 1152921 12163089 30762 375953 12883722 5915 12913279
225572 7461895 15423917 15173853 4141052 551397 15123841 5915 15513939
4751207
10302616 11382891 192488 6981773 12553188 325826 4501143 10812746 5915 1445367
10302616 11702972 187475 7261844 13533437
13523434
14383653 356927 4501143 14383653 5915 150381
114229014751207 223566 8692207 14213609 1584013 372945 5501397 1374349 5915 14583703
492125 11422901 1283251
1303302
12-14 NPSM
T-BOX
GND LUG
P DIA
2- NPSC
IN
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY
FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL
LENGTHS NOT SHOWN
INMM
PartModel Number
DR404AQ58M DR454V58M DR505AW58M DR513V58 DR656K58X
Specification Units 037778 080485 037935 038143 080603
Motor Enclosure - Shaft Mtl - SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS SPA (ODP)-CS TEFC-CS Horsepower - 10 15 20 15 30 Voltage AC 115230 115230 115230 115230 115230 Phase - Frequency - Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Single-5060 Hz Insulation Class - F F F F F NEMA Rated Motor Amps Amps (A) 1575 15276 21105 15276 31155 Service Factor - 14 13 12 13 10 Maximum Blower Amps Amps (A) 84 1785 2613 1785 278139 Locked Rotor Amps Amps (A) 3216 8543 13668 8543 200100 Recommended NEMA Starter Size- 000 10 10 10 151
Shipping Weight Lbs 64 76 83 90 51 Kg 29 345 376 408 231
Recommended Number of Jets - 3-6 5-10 5-10 12-17 8-12
Voltage - ROTRON motors are designed to handle a broad range of world voltages and power supply variations Our dual voltage 1 phase motors are factory tested and certified to operate on both 104-115208-230 VAC-1 ph-60 Hz and 100-110200-220 VAC-1 ph-50 Hz All voltages above can handle a plusmn10 voltage fluctuation Special wound motors can be ordered for voltages outside our certified range
Operating Temperatures - Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature) Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet or ambient temperatures above 40degC
Maximum Blower Amps - Corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andor ambient temperature reaches the maximum operating temperature
Notes- The blower should not be stoppedstarted more than four times an hour - Use of relief valve 515092 is required for all blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 404454505513656
Spa Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
bull Maximum pressure 56 58 74 69 or 88 IWGbull Standard motor 10 15 20 30 HP Spa Duty ODP
(threaded)bull
Class B rated thermal protectionbullbull Quiet operation within OSHA standards
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing optionsbull Remote drive (motorless) models
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bullbull Variable frequency drive package
UL amp CSA approved motor with permanently sealed ball bearings and
Blower Performance at Standard Conditions60 Hz 50 Hz
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
LegendPressureSuction
DR404DR454DR505DR513DR656
LegendPressureSuction
DR404DR454DR505DR513DR656
0 20 40 60 80 100 120 140 160 180 200 220 0 20 40 60 80 100 120 140 160 180 200 220
0 34 68 102 136 170 204 238 272 306 340 374 0 34 68 102 136 170 204 238 272 306 340 374
0
20
40
60
80
100
120
0
20
40
60
80
100
120
0
50
100
150
200
250
300
0
50
100
150
200
250
300
Temperature curves are based on standard model Temperature curves are based on standard model0
100
200
0
100
200
0
100
200
0
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
PartModel Number
DR10RDNT SS10RDNT HS10RDNT
Specification Units 036594
Shaft Material - Carbon Steel Stainless Steel Hastelloy Speed Range - 1750-4500 1750-4500 1750-4500 Housing Cover Cover - Cast Iron Stainless Steel Hastelloy
Shipping Weight Lbs 400 500 600 Kg 1814 2268 2722
SS = Stainless Steel HS = Hastelloy
1 DR10RDNT not recommended for use with explosive gas due to material of construction
2
3
4
Maximum operating temperature Blower outlet air temperature should not exceed 260degC (air temperature rise plus inlet temperature)Contact factory for use above 260degC blower outlet air temperature
AMETEK will not be liable for blowers operated beyond factory specic RPM
All applications must be reviewed Contact application engineering for assistance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
DR 10RDNTSS10RDNTHS 10RDNT
Remote Drive (Motorless) Blowers
FEATURESbull Manufactured in the USA - ISO 9001 and NAFTA compliant
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
bull Packaged on baseplate with V-belts or coupling guard amp motorbull High temperature Vitonreg sealsbull Krytoxreg grease high temperature bearings
PACKAGEMOTOR OPTIONSbull International voltage amp frequency (Hz)
bull Packing gland or double faced seal options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull External muers for additional silencingbull Variable frequency drive package
Note For accessories special high temperature models may be required
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Inpu
tH
orse
pow
er
Inpu
tH
orse
pow
er
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
er
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0 75 150 225 300 375 450 525 600 675 750 825
0 127 255 382 510 637 765 892 1019 1147 1274 1402
0
30
60
90
120
150
180
0
75
150
225
300
375
450
0
20
40
0
20
40
AIR T 100 ordmC
75 ordmC
50 ordmC
4500 RPM3500 RPM2500 RPM
1750 RPM
4500
3500
25001750
AIR T 100 ordm C
75 ordm C
50 ordm C
4500 RPM3500 RPM
2500 RPM
1750 RPM
4500
3500
25001750
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
1 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motorsor 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
Rev 204
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
MD101CB4 MODEL SHOWNTEFC MOTOR
MD101CC4 MODEL SHOWNXP MOTOR
Oslash9
8424
99
249
9
188478
478
169429
429
4121047
1047
1500381
6001524
1524
RESET BUTTONOslash 87 CONDUIT HOLE
22
350889
889
300
762
762
262
665
665
OUTLET INLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE71
71
Oslash9
84
188
169
8252096
412
1664216
600
LEADS FAR SIDE
350
300
262
OUTLETINLET
1-11 12 NPT2X
Oslash 28 MOUNTING HOLE
75-14 NPT
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN
INMM
ROTATION
ROTATION
PartModel Number
MD101CB4 MD101CC4
Specification Units 038014 038271
Motor Enclosure - Shaft Mtl - TEFC Explosion-proof Horsepower - 25 25 Phase - Frequency Voltage - Single-60 hz Single-60 hz Motor Nameplate Amps AC 115 115 Max Blower Amps Amps (A) 26 26 Locked Rotor Amps Amps (A) 22 22 Service Factor Amps (A) 64 72 Starter Size - 10 10 Thermal Protection - 00 00 XP Motor Class - Group - Class B - Automatic Manual Reset Class B - Automatic
- - I-D
Shipping Weight Lbs 40 40 Kg 181 181
F 21
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
MD 101 Magnetic-Drive
Regenerative Blower
FEATURESbull Hermetically designed seal-less blowerbull Continuous operationbull Manufactured in the USA
bull Maximum pressure 28 IWGbull Maximum vacuum 265 IWGbull Standard motor 025 HP TEFC or XPbull Disconnect motor without disassembling from piping
bull Permanently sealed ball bearings in housing and motorbull Quiet operation within OSHA standards
BLOWER OPTIONSbull Corrosion resistant surface treatments amp sealing options
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valvesbull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
0 3 6 9 12 15 18 21 24 27 30 330
5
10
15
20
25
30
0
12
25
37
50
62
750 5 10 15 20 25 30 35 40 45 50 55
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
AIRSG = 10
NATURAL GASSG = 056
NATURAL GASSG = 056
AIRSG = 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
NOTES1 DRAWING NOT TO SCALE CONTACT FACTORY FOR SCALE CAD DRAWING2 CONTACT FACTORY FOR BLOWER MODEL LENGTHS NOT SHOWN3 GVR313AK4H MODELS SHOWN
10502667
ROTA
TIO
N
375
953
14193604
113
8 (T
YP)
289
1
1 12 NPTF (2) PLACES (GVR313)
22559
4001016
IN OUT
68751746
421067
348688
224 49
124
5
65
165
1
BOTTOM VIEW
INMM
PartModel Number
GVR313AK4H GVR313AK58H GVR313AK72HA GVR313AK91H GVR313AE4HA
Specification Units 038584 081531 081470 081524 080274
Motor Enclosure - Shaft Mtl - Explosion-proof - CS Explosion proof - CS Explosion proof - CS ATEX - CS TEFC Horsepower - 05 05 05 075 05 Phase - Frequency Voltage - Single-60 hz Single-5060 Hz Three-60 Hz Three-50 Hz Single-60 Hz Motor Nameplate Amps AC 115 110220 230460 400 115 Max Blower Amps Amps (A) 94 8442 1407 14 74 Locked Rotor Amps Amps (A) 76 6834 1407 11 74 Service Factor Amps (A) 45 45 10251 9 47 Starter Size - 10 10 115 10 10 Thermal Protection - 0 0 00 0 0 XP Motor Class - Group - Class B - Automatic Class B - Automatic Class B - Automatic Thermistors Class B - Automatic
- I-D 1-D 1-D EExd IIB 1-D
Shipping Weight Lbs 39 39 39 45 39 Kg 177 177 177 204 177
1 115 voltage 1 phase motors are standard 230 volt motors available As an option a transformer could be used2 Maximum operating temperature Motor winding temperature (winding rise plus ambient) should not exceed 140degC for Class F rated motors
or 120degC for Class B rated motors Blower outlet air temperature should not exceed 140degC (air temperature rise plus inlet temperature)Performance curve maximum pressure and suction points are based on a 40degC inlet and ambient temperature Consult factory for inlet orambient temperatures above 40degC
3 Maximum blower amps corresponds to the performance point at which the motor or blower temperature rise with a 40degC inlet andorambient temperature reaches the maximum operating temperature
Rev 204
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 23Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Specific Blowers
GVR313
Regenerative Blower
FEATURESbull Manufactured in the USA
bull Maximum pressure 45 IWG bull Maximum vacuum 408 IWGbull Standard motor 05 HP TEFCbull Anodized cast aluminum blower housing impeller amp cover
bull Quiet operation within OSHA standardbull ROHS gold irridite coatings on aluminum surfaces
MOTOR OPTIONSbull International voltage amp frequency (Hz)
BLOWER OPTIONS
ACCESSORIESbull Flowmeters reading in SCFMbull Filters amp moisture separatorsbull Pressure gauges vacuum gauges amp relief valves
bull
Blower Performance at Standard ConditionsPressure Suction
Inch
es o
f Wat
er
mba
r
mba
r
Mot
or W
indi
ngTe
mp
Ris
e degC
Air Flow Rate - SCFMAir Flow Rate - SCFM
Air Flow Rate - m3hourAir Flow Rate - m3hour
Inch
es o
f Wat
erM
otor
Win
ding
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
Blo
wer
Air
Tem
p R
ise
degC
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
0 5 10 15 20 25 30 35 40 45 50 550
10
20
30
40
50
60
0
25
50
75
100
125
1500 9 17 26 34 43 51 60 68 77 85 94
Temperature curves are based on standard model Temperature curves are based on standard model0
50
100
0
50
100
0
50
100
0
50
100
GVR313
GVR313
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 F 24Customer Service Fax +1 2152561338 wwwametekdfscom
Accessories AMETEK Dynamic Fluid Solutions ROTRON brand has long been a world leader in regen-erative blower technologies bringing regenerative advantages to a new level providing quiet maintenance-free oil-free operation
Our accessories for regenerative blowers inlude
Filtration Accessories Measurement Accessories Noise Reduction Accessories Valves and Gauges
VFD Drives Air Knives
Blower Model Reference Key A = SPIRAL E = DRENCP656 6 633 S7 B= DRENCP068 083 101 202 F = DRENCP 757 808 858 S9 P9 (Inlet Only) C= DRENCP303 312 313 353 G= DRENCP833 S13 P13 (Inlet Only) D = DRENCP404 454 513 505 555 523 H = DRENCP909 979 1233 14 S15 P15 (Inlet Only)
Blower Connection Key NPTndash American National Standard Taper Pipe Thread (Male) NPSCndashAmerican National Standard Straight Pipe Thread for Coupling (Female) SO ndash Slip On (Smooth ndash No Threads)
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inlet Filter (Single Connection)
Inlet Filters protect the blower and the air distributionsystem from dust and other airborne particles andcontaminants Normally used in pressure systems
A
Oslash
B
C Oslash
SPECIFICATIONS HOUSING ndash Steel MEDIA ndash Polyester EFFICIENCY ndash 97-98 (8 to 10 micron particle size) FILTER ELEMENT ndash Replaceable (see filter elements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particle size) available
PartModel Number
Specification Units 477411 516466 515122 515123 515124 515125 515145 515151 516511
Filter Element - A B C D E E F G H H Ref Blower Model - 271078 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 200 SO 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 456 600 600 775 1000 1000 1000 1000 1600 mm 1158 1524 1524 1969 254 254 254 254 4064
Dimension B Inches 612 650 650 725 1225 1250 1300 1400 1500 mm 1554 1651 1651 1842 3112 3175 3302 3556 381
Dimension C Inches 200 100 15 200 200 250 300 400 600 mm 508 254 381 508 508 635 762 1016 1524
Z Media Filter PN - 517865 517866 517867 517868 517869 517870 517871 517872
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 11258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Inline Filter (Dual Connection)
Inline Filters protect the blower from harmful dustand other particles that may be drawn into theblower through the air distribution systemNormally used in vacuum systems
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron particle size)FILTER ELEMENT ndash Replaceable (see filterelements) NOTE ldquoZrdquo MEDIA (1 to 3 micron particlesize) available Feature 14 threaded tap for gauge connection on inlet and outlet
Inline lter PN 271200 is a straight through designInlet is directly opposite of outlet
D DIA
B
A
C DIA
PartModel Number
Specification Units 271200 516461 515254 515255 515256 516463 516465 517611
Filter Element - 271078 516434 516434 516435 516435 515135 515135 516515 Ref Blower Model - A B C D E F G H H Inlet Connection - 175 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M Outlet Connection - 200 SO 100 NPSC-F 150 NPSC-F 200 NPSC-F 250 NPSC-F 300 NPT-M 400 NPT-M 600 NPT-M
Dimension A Inches 525 725 700 800 800 1400 1400 1800 mm 1334 1842 1778 2032 2032 3556 3556 4572
Dimension B Inches 831 650 650 1025 1025 2650 2700 2800 mm 2111 1651 1651 2604 2604 6731 6858 7112
Dimension C Inches 200 100 150 200 250 300 400 600 mm 508 254 381 508 635 762 1016 1524
Dimension D Inches 175 100 150 200 250 300 400 600 mm 445 254 381 508 635 762 1016 1524
Z Media Filter PN - 517886 517887 517888 517889 517890 517891 517892
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Silencers (Single Connection)
FilterSilencers reduce noise levels whileensuring clean air is provided to the blower andthe air distribution system Normally used inpressure applications
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash PolyesterEFFICIENCY ndash 97-98 (8 to 10 micron size)FILTER ELEMENT ndash Replaceable (see filter elements)
A
Oslash
B
C
Oslash
PartModel Number
Specification Units 516487 516489 516491 516493 516495 516497 516499 516513
Filter Element - B C D E E F G H H Ref Blower Model - 515132 515132 515133 515134 515134 515134 515135 516515 Outlet Connection - 100 NPT 150 NPT 200 NPT 200 NPT 250 NPT 300 NPT 400 NPT 600 NPT
Dimension A Inches 600 600 1000 1000 1000 1000 1233 1600 mm 1524 1524 254 254 254 254 313 4064
Dimension B Inches 650 650 725 1225 1250 1250 1387 1500 mm 1651 1651 1842 3112 3175 3175 352 381
Z Media Filter PN - 517878 517879 517880 517881 517882 517883 517884 517885
Dimension C Inches 100 150 200 200 250 300 400 600 mm 131541012 131541266 13154152 131541774 131542028 131542282 131542536 13154279
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 31258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Filter Element
All ROTRON Air Filters and FilterSilencers have replaceable filter elements The filter media is polyester designed for high efficiency over a wide spectrum of industrial applications See yumllter element cross reference table Filter elements supplied with foam pre-filter
Standard Replacement Filter Element Cross Reference Table
271200 271078 515158 515134 516489 515132477411 271078 515254 516434 516491 515133515122 515132 515255 516435 516493 515134
515123 515133 515256 516435 516495 515134515124 515134 516461 516434 516497 515134515125 515134 516463 515135 516499 515135
515145 515134 516465 515135 516511 516515515151 515135 516466 515132 516513 516515515157 515133 516487 515132 517611 516515
HT
For DR Blower Models
OslashID
OslashOD
Filter Filter FilterElement Element Element
PartModel Number
Specification Units 515132 515133 515134 515135 516434 516435 516515
Z Media Filter PN - 517873 517874 517875 517876 517893 517894 517877
Dimension ID Inches 300 363 35 475 256 350 800 mm 762 922 889 1207 65 889 2032
Dimension OD Inches 438 588 588 788 500 588 1175 mm 1113 1494 1494 2002 127 1494 2985
Area SqFt 475 475 950 963 475 875 963 SqM 0 0 1 1 0 1 1
Dimension HT Inches 15 23 45 83 20 45 190 mm 381 584 1143 2108 508 1143 4826
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 G 41258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
By separating and containing entrained liquidsROTRONrsquoStrade moisture separator helps protect our regenerative blowers and the end treatment systemfrom corrosion and mineralization damage Recommended for all soil vacuum extraction Applications
applications
PLASTIC ldquoPrdquo DESIGN METAL ldquoDrdquo DESIGN METAL ldquoBrdquo DESIGN
SPECIFICATIONSSEPARATION METHOD ndash High Effciency Cyclonic RELIEF VALVE MATERIAL ndash Brass amp Stainless SteelFLOAT MATERIAL ndash CopperFLOAT SWITCH ndash SPDT Explosion-proof
NEMA 7amp9 5 Amp max
(OPTIONAL)
VALVE
(OPTIONAL)
ODINLET
(PLUGGED) SWITCH(OPTIONAL)
G
D
H
H
(PLUGGED)
C
J
B
34NPT
CAPACITY(PER CHART)
EF
390
(OPT
ION
AL
LOW
SW
ITCH
)
SWITCH(OPTIONAL)
INLET
H
B
DJ
E
F
(OPTIONAL)
(PLUGGED)
B
VALVE
(OPTIONAL)
J
D
C
E F
G
VALVE
34NPT
INLETOD
FLOAT SWITCH
34 NPT
VACUUM RELIEF
VACUUM GAUGE
14 NPT FLOAT LEVEL 14 NPT
DRAIN
WATER LEVEL
DRAIN - 1 NPT INTERNAL THD
FLOAT LEVEL
OD
VACUUM GAUGE
14 NPT
VACUUM RELIEF
VACUUM GAUGE
VACUUM RELIEF
DRAIN
TMMOISTURE SEPARATOR
RAP AT ORI SO T U R E
EM
S
A
A
INSTALL FLOAT SW
INFO PACKET
MOISTURE SEPARATOR
TM CYCLONICACTIONCAUTIONFREEZING MAY CAUSE DAMAGEMOISTURE SEPARATORS USED IN TEMPERATURES BELOW 32oslashF (0oslashC)MUST BE PROPERLY WINTERIZED
A
T ORURE
G
OUTLETOUTLET
OUTLET
PartModel Number
MS200PS MS300PS MS350BS MS500BS MS600BS MS1000BS
Specification Units 038519 038520 038357 080660 080659 038914
Dimension A Inches mm
238 605
288 732
325 826
325 826
400 1016
600 1524
CFM Max CFM m3hr
200 340
300 510
350 595
500 850
600 1020
1000 1700
Dimension B Inches mm
2246 5705
2246 5705
2800 7112
2800 7112
2700 6858
3100 7874
Dimension C Inches mm
1600 4064
1600 4064
2300 5842
2300 5842
2300 5842
2700 6858
Dimension D Inches mm
325 826
325 826
400 1016
400 1016
400 1016
400 1016
Dimension E Inches mm
3105 7887
3105 7887
3725 9462
3737 9492
3737 9492
4732 12019
Dimension F Inches mm
3330 8458
3330 8458
3950 10033
5450 13843
5450 13843
5170 13132
Dimension H Inches mm
6 1524
600 1524
975 2477
975 2477
925 235
1000 254
Dimension G Inches mm
450 OD 1143
450 D 1143
450 OD 1143
663 ID 1684
663 ID 1684
862 OD 2189
Dimension J Inches mm
1325 3366
1325 3366
1750 4445
1750 4445
1750 4445
1988 505
Drain Internal Thd - 34 34 1 1 1 1
Shipping Weight Lbs Kg
42 191
42 191
82 372
95 431
96 435
150 68
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Filtration - Moisture Separator
404
ForDRENCP
BlowerModel
SelectorMoistureSeparator
Model
Liquid-holdingCapacity(gallons)
Inlet(OD)
Outlet
MaxVacuum
Allow(IHG)
454
MS200PS 7 238 12
45 OD
MS300PS 7 288
MS350BS
MS500BS 40325
MS600BS 40663 ID 22
MS1000BS
Pre
ssur
e D
rop
(IWG
)
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
1
2
3
4
5
6
Flow Rate (SCFM)
65 60 862 OD
505513523555633833656
6757808
909
8581233
97914
The moisture separator shall be designed for use in a soil vapor extraction system capable of continuous operation with a pressure drop of less than six inches of water at the rated ow of _____ SCFM The separator shall be capable of operation under various inlet conditions randing from a ne mist to slugs of water with high eciency
The moisture separator shall incorporate cyclonic separation to remove entrained water The separator must protect against an overow by fail safe mechanical means An electrical switch or contact(s) alone is not an acceptable means of protection against overow but is a good backup
The body of the moisture separator shall be constructed of heavy wall plastic or heavy gauge cold rolled steel The steel interior and exterior shall be epoxy (powder) coated to resist abrasion corrosion and chipping that might expose the surface The inlet shall be tangentially located and welded to the body The outlet port shall be constructed of PVC or cast aluminum alloy anged and sealed to the center of the top of the separator The separator shall incorporate a non-sparking copper oat ball and an adjustable relief valve to protect against overow and overheating the blower
The moisture separator must have a liquid capacity of _____ gallons The inlet shall be _____ inch OD slip-on type The outlet shall be _____ inch OD slip-on type
20 Moisture SeparatorTM Specications
21 Duty
22 Principle of Operation
23 Construction
24 Capacity and Dimension
25 Pressure Drop
MS2
00PS
MS3
00PS
MS3
50BS
MS5
00BS
MS6
00BS
MS1000
BS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
FEATURESbull Direct reading in SCFMbull Low pressure drop (2-4 typical) across
the flow meterbull Non-clogging low impedance air streambull Light weight aluminumbull No moving partsbull Large easy-to-read dialbull Accurate within 2 at standard conditionsbull Good repeatabilitybull Available in 2 3 and 4 sizesbull Factory conyumlgured for quick installationbull 048 Allen key supplied for gauge adjustment
OPTIONSbull Corrosion-resistant version with Chem-Tough
trade or in stainless steelbull FDA-approved Food Toughtrade surface conversion
BENEFITS
bull OPTIMIZE SYSTEM EFFICIENCY Measuring the correct air ˜ow canassist you in yumlne-tuning to yoursystemrsquos optimal efficiency
bull BALANCE MULTI-PIPING SYSTEMSWhen evacuating CFM from more than onepipe di˝erent run lengths or end systemimpedance can cause one pipe to handlemore CFM than the other With an accurateCFM reading piping can be balanced bybleeding air inout or by creating an extraimpedance
bull DETECT CHANNELING OR PLUGGINGFor systems in which channeling orplugging can occur a change in the CFMmeasured can help indicate the unseenchanges in your system
PartModel Number
FM20C030Q FM20C045Q FM20C065Q FM20C125Q FM20C175Q FM20C225Q
Specification Units 550599 550600 550601 550602 550603 550604
Flow Rate CFM 6-30 9-45 13-65 25-125 35-175 45-225 m3hr 10-50 15-77 22-111 43-213 60-300 77-383
Threads B - 2-115 2-115 2-115 2-115 2-115 2-115
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
PartModel Number
FM30C250Q FM30C350Q FM30C475Q FM40C450Q FM40C600Q FM40C850Q
Specification Units 550605 550606 550607 550608 550609 550610
Flow Rate CFM 50-250 70-350 95-475 90-450 120-600 170-850 m3hr 85-425 119-595 162-808 153-795 204-1020 289-1445
Threads B - 3-8 3-8 3-8 4-8 4-8 4-8
Dimension C Inches 718 718 718 718 718 718 mm 1824 1824 1824 1824 1824 1824
Dimension D Inches 70 70 70 58 58 58 mm 1778 1778 1778 1473 1473 1473
Dimension E Inches 20 20 20 20 20 20 mm 508 508 508 508 508 508
Dimension F Inches 375 375 375 375 375 375 mm 953 953 953 953 953 953
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Air Flow Meter
HOW IT WORKSHIGH TEMPERATURE PRESSURE CORRECTION
TYPICAL FLOW METER ARRANGEMENT
ROTRONrsquoS ˜ flow meter is a venturi style designAfter air enters the inlet the pressure ismeasured in the P1 tap The second tap P2measures the pressure at the throat Thedifferential between P1 and P2 registers across a special calibrated CFM gauge to provideaccurate readings The throat is then expandedback to the original size to keep pressure loss tounder2-4 IWG
SCFM 1SCFM 2 =
147 x 530Pf2 Tf2 + 460radic( ) ( )
Pf 2 = Absolute Pressure inPSIA Tf2 = Temperature in degF
bull Use on inlet to limit need to correct for highpressure or elevated outlet temperature
bull Standard model limits = 140degF and 30 PSIG
TYPICAL GAUGE FACE
REGENERATIVE BLOWER GROUP
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
FLOW DIRECTION
375
375
20
287DIA
556
175
35REGENERATIVE BLOWER GROUP
C
P R E S S U R E 3 0 P S I G
XAM
014070
210 280
350
MINIHELIC II
B
OslashF
TMMOISTURE SEPARATOR
R A PATORIS OTURE
EM
S
BLOWER
INLET FLOWMETER SYSTEM UNDER VACUUM
SYSTEM PIPING
P RE S SUR E 3 0
P S I GXAM
014070
210 280
350
MINIHELIC II
AMETEKROTRON TIPTECHNICAL amp INDUSTRIAL PRODUCTS
IN OUT
P1 P2
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Measurement - Digital Flowmeter
316
187
3583
3780
1 2 3 4
2596
275
48114
350 100
Oslash16 (2X)MOUNT HOLES
OUT
LOW
HIGH
-COM
+EXC
189 169
551
Remote air flow rate monitoring and system automation control can now be achieved through the use of 4-20 mA output signalsOur 4-20 mA analog outputs are proportional to system flow rates and can be used with PLC controlled operations to monitorsystem performance Those same outputs provide digital displays for direct readings in SCFM when paired with our LCD DigitalReadout option Combined with our Variable Frequency Drives you can now achieve a completely automated system capable ofadjusting blower performance to meet changing system demands Maintaining your system at peak performance gives yourcompany the competitive edge needed in todayrsquos marketplace
FM20S030Q FM20S045Q FM20S065Q FM20S125Q FM20S175Q FM20S225Q FM30S250Q FM30S350Q FM30S475Q FM40S450Q FM40S600Q FM40S850Q 550838 550839 550840 550841 550842 550843 550844 550845 550846 550847 550848 550849
LCD DISPLAYFM20L030Q FM20L045Q FM20L065Q FM20L125Q FM20L175Q FM20L225Q FM30L250Q FM30L350Q FM30L475Q FM40L450Q FM40L600Q FM40L850Q 550860 550861 550862 550863 550864 550865 550866 550867 550868 550869 550870 550871
DIFFERENTIAL PRESSURE TRANSMITTER 4-20 mA signal output control signals provide flow rate monitoring capabilities from remote locations NEMA 1R-raintight enclosure orotects the integrated DC power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter Weight 3 lbs Signal Output 4-20 mA DC1
HiLo pressure fittings feature snap lock action to unsure trouble-free connections2
System includes standard flowmeter for on-site readings and troubleshooting Operating temperature 0oF to 150oF Drawing available
LCD DIGITAL READOUT OPTIONS Factory configured to display direct readings in SCFM to a remote location up to 50 from signal output1 NEMA 4 IP65 enclosure ready for panel mount instlation power supply and rugged differential pressure transducer Suitable for remote mounting up to 10 form flow meter installation Power input 120 VAC 5060Hz AC Field configurable to 240VAC Display 5 digit 7 segment 5 high LED w33Hz update rate Operating temperature 10oC to 40oC Weight 1lb 14oz
Drawing available Note 1 4-20 mA output control wiring to be customer supplies Shielded 2 conductor cables 22 AWG is recommemeded for runs up to 100 For longer runs contact factory
Note 2 Use 516 OD stiff wall tubing-connect Lo on flowmeter to Lo on 4-20 mA enclosure Hi on flowmeter to Hi on 4-20 mA enclosure Tubing must be equal in length (Maximum length is 1o feet)
DIFFERENTIAL PRESSURE TRANSMITTER
USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 9Customer Service Fax +1 2152561338 wwwametekdfscom
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477
____
Accessories
Noise Reduction - Sound Attenuating Enclosure
Frameless sound attenuating enclosures are a proven way to reduce regeenrative blower mechanical noise when additional mufflers are just not enough Additional enclosure options are available
FEATURESExcellent noise reduction (~10DbA)Resistance to elements and aesthetic appearanceCompact size for ease of installationEasy access for routine maintenance (removable foor and sidewalls)
SPECIFICATIONS Roof floor and walls galvanized 16 ga carbon steel sheet metal Louvers andor hood Riveted aluminum Hardware Chrome plated aluminum handles with stainless steel fastners Latches Over center glvanized with adjustable tension and padlock eye Sound attenuating material 2 rigid polyester foam with mylar facing (rated UL-94) Exterior finish Polyurethane enamel
3000
5000
4600
LIFTING HOLE(PLUGGED)TWO (2) PER SIDE(TOTAL 4)
950
950
END SECTION
END SECTION3100 CLEAR
1500
18 FANASSEMBLY
200 200
2600 CLEAR
Enclosure ventilation 13 HP 230460V 3-phase or 1-phase 5060Hz fan TEFC or XP motors Fan Guard Nickel plated wire type
PartModel Number
SAE30W72F SAE36W72F
Specification Units 552904 552905
Width Inches 30 36 mm 762 9144
Blower Size - 656 707 757 808 858 909 979 P9 S9 14 P13 S13 P15 S15
Height Inches 46 52 mm 11684 13208
Length Inches 50 60 mm 1270 1524
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 10Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - InletOutlet Muffler (Single Connection)
Muers lower blower noise in areas where reduced sound levels are required
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
D
C
B
A
PartModel Number
Specification Units 523627 523626 523625 523624 523623 523622
Ref Blower Model - B C D E E E Inlet Connection - 10 NPT Male 125 NPT Male 150 NPT Male 200 NPT Male 200 NPSC Female 200 NPT Male
Dimension A Inches 400 400 400 400 400 400 mm 1016 1016 1016 1016 1016 1016
Dimension B Inches 1093 1093 1093 1093 1093 1575 mm 2776 2776 2776 2776 2776 4001
Dimension C Inches 1398 1407 1457 1216 1243 1695 mm 3551 3574 3701 3089 3157 4305
Dimension D Inches 100 125 150 200 200 200 mm 254 318 381 508 508 508
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Noise Reduction - Inline Muffler (Dual Connection)
Inline Muers are utilized for noise reduction inapplications where piping systems are connected directlyto both ends of the muer Muer may be used on inletor outlet of blower
SPECIFICATIONSHOUSING ndash SteelMEDIA ndash Acoustical Material
C
B
A OUTLETCONNECTION
INLETCONNECTION
PartModel Number
Specification Units 550888 522948 529900 551377 515185 511569 515210 551565 516264
Ref Blower Model - D E E E F G G G H Inlet Connection - 15 NPT-M 20 NPT-M 20 NPSC-F 20 NPT-M 25 NPT-M 30 NPT-M 40 NPT-M 40 NPT-M 40 NPT-M Outlet Connection - 20 NPT-F 20 NPSC-F 20 NPSC-F 20 NPT-M 25 NPT-F 30 NPT-F 40 NPT-F 40 NPT-M 40 NPT-F
Dimension A Inches 400 400 438 400 612 700 1000 1000 800 mm 1016 1016 1113 1016 1554 1778 254 254 2032
Dimension B Inches 775 1575 1575 1575 1500 1800 2400 2400 2200 mm 1969 4001 4001 4001 381 4572 6096 6096 5588
Dimension C Inches 155 1845 1845 1815 1900 2225 3000 3000 2775 mm 3937 4686 4686 461 4826 5652 762 762 7049
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Relief Valve - Mechanical
Part Model Number
Specification Units 551026 551027 523230
Ref Blower Model - B C D D E F A B C D E F
Range in H2O mbar
20-180 498-4484
415-263 1034-6551
35-90 872-2242
Connection - 1 12 2 Description - Mechanical Mechanical
2 Mechanical Vacuum Only
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS G 13 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Pressure Regulating Diaphram Valve
PRESSURE RELIEF B is the system port and A is the vent or atmospheric port
VACUUM RELIEF A is the system port and B is the vent or atmospheric port For vacuum mode customer must remove snap ring and screen
NOTE Replace cap after adjusting setting Valve will not operate with cap removed Differential adjustment screw is under the cap
Fig 1 Fig 2
NOTE Blower Model P13 requires two 515093 relief valves
The PRD Valve is installed to prevent excessivesystem pressure or vacuum that could result fromline restrictions Valves should be installed at theblower outlet (downstream) in pressure systemsand at blower inlet (upstream) in vacuum systemsThese valves are suitable for air natural gaspropane and other non-corrosive service
Note PRD valves are not factory preset but areeasily field adjustable
SPECIFICATIONSVALVE BODY ndash Aluminum (1) CastIron (2) VALVE SPRING ndash SteelDIAPHRAGM ndash Nitrile
D
C
DIFFERENTIALADJUSTMENTSCREW
A
BGAUGEPORT
SEENOTE
GAUGEPORT
A
B
D
C
PartModel Number
Specification Units 515092 529612 529857 529858 551130 515093 529859 550246 550247
Range in H2O 27-125 110-415 277-554 7-18 14-62 48-194 110-277 97-197 97-194 mbar 673-3114 274-10338 690-1380 174-448 349-1544 1196-4833 274-690 2416-4907 2416-4833
Description - Fig 1 Fig 1 Fig 1 Fig 2 Fig 2 Fig 2 Fig 2 Pressure Vacuum Ref Blower Model - B C D E B C D E B C D E F G F G F G F G H H Inlet Connection - 1 1 1 2 2 2 2 25 25 Outlet Connection - 1 1 1 2 2 2 2 25 25
Dimension A Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension B Inches 100 100 100 200 200 200 200 250 250 mm 254 254 254 508 508 508 508 635 635
Dimension C Inches 412 412 412 712 712 712 712 619 619 mm 1046 1046 1046 1808 1808 1808 1808 1572 1572
Dimension D Inches 870 870 870 900 900 900 900 765 765 mm 221 221 221 2286 2286 2286 2286 1943 1943
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 14Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Protection - Gauges
ROTRON has a variety of gauges for pressurevacuum and temperature measurements invarious ranges These gauges are reliable andrugged
SPECIFICATIONS
Pressure Vacuum TemperatureCASE ndash Drawn Steel Finished CASE ndash Steel
LENS ndash GlassACCURACYndash 1
in Black EnamelDIAPHRAGM ndashBronze LENS ndash ClearPlastic ACCURACYndash2WEIGHT ndash 12 lbCONNECTION ndash 14NPT FACE ndash 2 12 dia
WEIGHT ndash 14 lbCONNECTION ndash 12NPT FACE ndash 3 Dial
Pressure Vacuum
Temperature
200
180
160
140
120100
80
60
40
20
100
50
150
200 250
350
400
300
degF
degC
10
0
1
2
3
4
5
6
PRESSURE
0
2040
60
80 100
120140
160
P S INCHE S OF WAT E RI
25 plusmn03Oslash 318 plusmn12
250 plusmn06
338 plusmn12
12 NPT CONNECTION
PartModel Number
Specification Units 551376 271949 529428 271950 551368
Range - Pressure Pressure Vacuum Vacuum Temperature Description - 0-60 IWG 0-160 IWG 0-60 IWG 0-160 IWG 0-200 Deg C
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 15Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Variable Frequency Drive
A Variable Frequency Drive (VFD) is an adjustable speed AC motor control designed to speed the blower RPM up or down Our VFDs are designed to minimize losses and deliver increased efficiency low maintenance and the long life expected from the ROTRON product line
FEATURESbull
ncy by controlling motor RPMsbull Accepts 3Oslash or 1Oslash inputs to drive 3Oslash motor blower
assembliesbull Accepts 4-20 mA 0-5 VDC or 0-10 VDC inputs forsystem automation control and intregation
bull Provides dynamic breaking capabilitiesbull Replaces motor starter functionbull Digital readout in either Hz or RPMsbull Keypad enclosure (NEMA4X-Indoor) vsn be
mounted up to 100 from controller with cable assembly option
SYSTEM REQUIREMENTSbull In cases where the distance between the controller
and motor exceed 50 the use of a line reactor on load side is needed
bull XP motors must be UL listteedd for use with a Variable Frequency Drive
VARIABLE FREQUENCY DRIVE SELECTIONThere are some common guidelines in sizing a VFD for use on a AMETEK ROTRON blowers such as the allowable speed(table 1) for a given motor type To determine the required RPM to achieve a desired flow and pressure form a specific bloewr turn to the blower performance at variable speeds in section E of this catalog The required RPM must fall within the allowable rate of the motor being used
Motor Allowable Turndown Allowable Speedup
Standard 3600 RPM to 1800 RPM mdash3600 RPM to 900 RPM mdash
Inverter Motor 3600 RPM to 360 RPM 3600 RPM to 7200 RPM
Turndown of 101 is not typically done with regenerative blower designsFor all applications above 3600 RPM contact your Field Sales Engineer for proper horsepower sizing
Table 1
Specification
Model Number Part Number Description
IV101AE58 551529 1151 Up to 05 HP DR068-DR303 IV102AE58 551530 2301 Up to 05 HP DR068-DR303 IV101AL58 551531 1151 075 to 10 HP DR353-DR404 IV102AL58 551532 2301 or 3 075 to 10 HP DR353-DR404 IV103AL72 551533 4603 075 to 10 HP DR353-DR404 IV102AS58 551534 2301 or 3 15 to 20 HP DR454-DR505 IV103AS72 551535 4603 15 to 2 HP DR454-DR505 IV102K58 551536 2301 or 3 25 to 3 HP DR505-DR555 IV103K72 551537 4603 25 to 30 HP DR505-DR555 2301 IV102D58 551538 or 3 35 to 5 HP DR555-DR808D 4603 IV103D72 551539 35 to 5 HP DR555 to DR808D 2303 55
IV152AY58 551540 to 75 HP DR808-DR858 4603 55 to 75 IV152AY72 551541 DR808 ndash DR858 IV152BB58 551542 2303 8 to 10 HP DR858-DR909 IV153BB72 551543 4603 8 to 10 HP DR858-DR909 IV152BC58 551544 2303 105 to 15 HP DR909 IV153BC72 551545 4603 105 to 15 HP DR909 IV152BH58 551546 2303 155 to 20 HP DR9 DR14BH IV153BH72 551547 4603 155 to 20 HP DR9 DR14BH IV152BP58 551548 2303 205 to 30 HP DR13 DR14 IV153BP72 551549 4603 205 to 30 HP DR13 DR14 IV152BQ58 551550 2303 305 to 40 HP DR15 IV153BQ72 551551 4603 305 to 40 HP DR15 IV153ED72 551552 4603 505 to 60 HP DR15
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 16Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
SINGLE-ENDED SIDE VIEW DOUBLE-ENDED SIDE VIEW
Air knives 30 and smallerMOUNTING VIEW
CAPPED END VIEW
CL CL25-8 NPT(TYP)
CL CL25-8 NPT(TYP)
GAP SETTINGRAIL(REF)
CL
PER MODEL
CL CL
25-20 UNC THRU
25-20 UNC X 75 LG
315 TYP
315TYP
L
458
458
22
22
075
175
10 STYP
L
PartModel Number
AK06S060 AK12S060 AK18S060 AK24S060 AK30S060 AK36S060 AK42S060 AK48S060 AK54S060 AK60S060
Specification Units 523489 552955 522949 553000 522950 523492 523493 523494 523495 523496
Length (L) Inches 930 1530 2130 2730 3330 4230 4830 5430 6030 6630 mm 2362 3886 541 6934 8458 10744 12268 13792 15316 1684
Slot Length Inches 6 12 18 24 30 36 42 48 54 60 mm 1524 3048 4572 6096 762 9144 10668 12192 13716 1524
Dimension S Inches 400 1000 1600 2200 2800 1700 2000 2300 2600 2900 mm 1016 254 4064 5588 7112 4318 508 5842 6604 7366
The ROTRON air knife is located at a strategicpoint in your assembly line conveyor beltarea Air ows from the blower into the airknife where a sheet of air is directed outthrough a proprietary linear nozzle designonto assembly line parts The opening canbe altered to adjust the air-ow rate thusvarying blow-o velocity to meet yourapplication requirements
Air KnivesAn Oil-free Blowing and Drying SystemCustom-t for Your Application
FEATURESbull Lightweight aluminum plenum and rail steel end cap
and cast-iron NPT angesbull Engineered extruded design to achieve 95 eciencybull Adjustable slot (pre-set at 0060) to control velocity
from 5000-35000 fpmbull Custom cut lengths to t system restraintsbull Oil-free and lower cost alternative to compressed air for
blow-o solution blow-back and drying applications
OPTIONSbull Chemical resistant designs utilizing Chem-Tough TM
chemically resistant surface conversion stainless steel hardware and nickel plated end caps and anges
bull Food processing grade designs utilizing Food-Tough TM
sanitary treatment surface conversion stainless steel hardware and nickel plated end caps and anges
bull Deionizers for sterile environments availablebull Mirror image single-ended models for above and below
conveyor operation
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 17Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - Air Knives
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800SCFM
Air Velocity
Precision Cleaning Air Knife and Blower Selection Chart
DR656
DR757
DR808 DR858
DR909
DRP9
DR979
DRP13
DR14
DRP15
6 knife
12 knife
18 knife
24 knife 30
knife 36 knife
42 knife
48 knife 54
knife60
knife
40000 FPM
35000 FPM
30000 FPM
25000 FPM
20000 FPM
15000 FPM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 18Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
air
These unique solenoid actuated diverter valves automatically change air piping from pressure to suction greatly enhancing blower versatility and productivity This valve is effective in blower applications that require frequent switching frompressure to suction and vice-versa They are costeffective as applications normally requiring twoblowers andor intricate piping systems may be accomplished with one blowerDiverter valves may be purchased as blowervalve assemblies or as separate stand-alone valve assemblies for use in other switched air applications
SPECIFICATIONSbull Aluminum body and spool assemblybull 303 stainless steel shaftbull 115 V-60 Hz solenoid valve
OPTIONSbull Corrosion resistant surface treatmentsbull International voltage and frequency (Hz)bull Application specific designs
DR 505 BLOWER WITH DIVERTER VALVEThe principle behind ROTRONrsquos diverter valve system is asimple one Some applications such as vacuum part pick-up airtables and pneumatic tube systems require both vacuum andpressure in their equipmentrsquos operation but not simultaneouslyThey eliminate the need for two sep-arate blowers andelaborate valving system or cyclingreversing a spinningblower impeller ROTRONrsquos diverter valve changes the airpassageways By utilizing the side vent ports for incoming oroutgoing air the equipmentpiping side of the valve changesfrom vacuum to pressure and back again by a signal sent to thesolenoid coil
PartModel Number
Specification Units 515554 037435 037482
Description - DR404 DR454 DR505 DR6 DR808 DR858 DR6 DR808 DR858 Ref Blower Model - Small Large Large Piping Flange - Threads Threads Threads Blower Flange - Face Threads Face
Dimension A Inches 765 925 925 mm 1943 235 235
Dimension B Inches 1422 2339 2339 mm 3612 5941 5941
Dimension C Inches 714 1093 1093 mm 1814 2776 2776
Dimension D Inches 250 355 355 mm 635 902 902
Dimension E Inches 500 710 710 mm 127 1803 1803
Dimension F Inches 150 250 250 mm 381 635 635
Dimension G Inches 150 250 250 mm 381 635 635
Consult factory for proper selection and application
SOLENOID
ENERGIZED POSITIONSUCTION AIR PATH
SOLENOID
DE-ENERGIZED POSITIONPRESSURE AIR PATH
A
D
BF
C
EG
EQUIPMENTPIPING SIDE ISO VALVE DRAWING
BLOWER SIDE
WORKINGPART
SUCTION PRESSURE
BlowerBlower
IN OUT IN OUT
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 19Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
System - 5 Way 3 Port 2 Position Diverter Valve
ROTRON RELEASED BLOWERS WITH DIVERTER VALVE MOUNTED Model Part No Mounted Components Diverter Valve Manifold
DR353BR58MV 080757DR404AL72MV 037749 517077DR404AL58MV 037715 DR454R72V 037605 515554
529397DR454R58V 037122DR505AS72MV 037709
517459DR505AS58MV 037554
037482 DR808AY72WV 080084
550667DR858BB72WV 080085
DIVERTER VALVE MANIFOLD
bull Models listed below include diverter valve and manifold
A = SPIRAL E = DRENCP 656 6 633 S7B = DRENCP 068 083 101 202C = DRENCP 303 312 313 353 G = DRENCP 833 S13 P13 (Inlet Only)D = DRENCP 404 454 513 505 555 523 H = DRENCP 909 979 1233 14 S15 P15 (Inlet Only)
F = DRENCP 757 808 858 S9 P9 (Inlet Only)
Blower Model Reference Key
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 20Customer Service Fax +1 2152561338 wwwametekdfscom
____
Accessories
Pressure amp Vacuum Arrangements
Pressure or vacuum guages should be located in the delivery line oriented as shown Assure that the guage is approxi-mately three pipe diameters from the blower delivery ange and that the relief valve is located at the same spacing from the guage 90deg elbows should be located at least ve pipe diameters from the blower delivery ange Elbows taps tees valves or other restrictions to air ow should not be located between the blower delivery ange and accessories described above
Failure to observe these precautions can result in false readings of guages and failure of the relief mechanism to protect the blower from overload
In order to avoid overheating or distortion of PVC pipe the rst ve to eight feet from the blower delivery ange on pressure systems should be metal
Typical Pressure System
Typical Vacuum System
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 G 22Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Motor Options
ROTRON strives to provide the most complete variety of desired options on our products including on our motors By using motor vendors of high quality and versatility we can provide motor features from multiple released designs to meet your needs (ie a Chem Processing Inverter Duty Explosion-proof motor with space heaters and drains wound for 380 V-50 Hzservice)
Design Consistency
ROTRON motors are engineered for us to integrally mount with our blower and maximize blower performance Our vendors are qualied by ROTRON (per motor part number) to ensure the blowersrsquo mechanical and electrical needs merge with your required features The basic motor requirements on our DRENCPHiE products include
bull NEMA approved
bull CE conformity (non-XP models)
bull UL amp CSA approved with symbol and file on nameplate
bull C-face mount
bull Permanently sealed bearings
bull Shaft end play run out and perpendicularity requirements above NEMA standards
bull Dual voltage and dual frequency (some models not feasible) to maximize use worldwide
bull Single Shafted Totally Enclosed Fan Cooled (TEFC) and Explosion-proof (XP) models
bull Double Shafted Open Drip Proof (ODP) models with dual internal fans for circulation
bull Class I Group D minimum on explosion-proof motors many are Class I Group D Class II F amp G
bull Commercial Spa (SPA-ODP) motors with automatic thermaloverload protection and industry specied terminal strip
Standard Motor Variations
Chemical Processing (CP) features are added to TEFC XP or HiE designs for corrosive gas service Marine Duty service and sanitary (foodpharmaceutical) service
bull 303 stainless steel shaft
bull Cast iron and steel frame epoxy painted or zinc plated
bull Zinc plated hardware
bull Stainless steel nameplate
bull Non-hygroscopic insulation double dipped and baked stator
bull Epoxy coating on rotor
bull Gaskets and joint sealers on all metal-to-metal surfaces
bull Oversized conduit box
High Efficiency (HiE) features are added to TEFC ODP XP or CP motors for maximum motor eciency and life ROTRON HiE motors carry extra phase-to-phase protection for use withinverters between a 1750-3500 RPM range
Inverter Duty features are added to TEFC ODP XP or CP for use with InvertersVariable Speed Drive Controllers A wide range of RPM can be handled and should be specified at time of quote For best compatibility an inverter should be matched to the motor manufacturers design
Project Specic Motor Variations
There are no limits to the options you can select or request for your product Routine motor options include
bull International voltage amp frequency (Hz)
bull Different shaft material
bull Oversized andor Nema 4 intent T-box
bull Space heaters
bull Drains
bull Regreasable bearings
bull Tropicalized windings
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Typical Sealing Options
Lo-Leaktrade LIP SEAL Option
The Lo-LeaktradeLip Seal option is available to control gas leakage for all DR models and is standard on all EN and CP models Features include Lip seals to prevent leakage at the motor shaft RTV sealingcompound is used to cut o all leakage paths at the blowerrsquos metal-to-metal surfaces Castings are vacuum impregnated to prevent leakage through castings Estimate leakage rate = 25 ccmin or less
Double Face Carbon Seal Option
For further minimization of gas leakage on all DR EN and CP models a pair of face seals work against each other on opposite sides of a common mating ring to eectively reduce gas leakageat the motor shaft The face shields are continually lubricated from a reservoir to prolong seal life The seal is completed by installing the blower to motor bolts with O-rings and sealingthe covers to the housing with an RTV sealing compound O-rings are also placed between the pipe anges and the manifold All castings are vacuum impregnatedEstimate leakage rate = 05 ccmin or less
Hermetically Sealed Spiral Containment Option
The containment option utilizes a series of O-rings to control gas leakage in Spiral blower models The O-rings are placed at critical locations on the blowerrsquos housing and covers to contain gas leakage
Hermetically Sealed Mag Drive Option
On DR EN and CP 101 units a magnet drive option has been an alternative for complete gas containmentO-rings are used throughout the product and magnets attached to the motor shaft spin magnets inside the blower without shaft penetration Estimated leakage rate = 0001 ccmi
Nitrogen Purge Blanket Option
The nitrogen purge option is a carrier designed to accept a nitrogen line which will purge the space outside the shaft hole Purges can be designed to bleed the nitrogen into the process called a blanket or the carrier can have a second tap to carry away the leaking contaminants
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chem-Toughtrade Chemical Resistance
To stand up in corrosive and hazardous environments chemical processing blowers have to be tough Thatrsquos why Ametek ROTRON routinely applies Chem-Toughtrade ROTRONrsquoS own engineered and proprietary process whenever it builds blowers for handling chemical (vapor) streams Chem-Toughtrade combines the advantages of aluminum oxide ceramic and selected uorocarbons to give ROTRON blowers unheard-of levels of chemical resistance hardness abrasion resistance permanent lubricity and more
Chem-Toughtrade Brings You the Rotron Advantage
Through this unique proprietary process Chem-Toughtrade gives ROTRON blowers these advantages
bull Outstanding Chemical ResistanceTime after time Chem-Toughtrade nishing shows extremely high resistance to most common chemicals as well as dramatically improved corrosion resistance over regular hard anodizing Chem-Toughtrade allows aluminum to achieve equivalent corrosion resistance as teonreg 90-day immersion in acid or alkaline solution (pH 40-85) has no eect neither does prolonged exposure to salt water Far exceeds military specication requirements for salt spray
bull Abrasion Resistance Equivalent to Steel Excellent for smooth surfaces Chem-Toughtrade surfaceconversion provides higher wear resistance than eithercase-hardened steel or hard-chrome plate Rub any other metal against the Chem-Toughtrade nish and the metal will show nothing but the slightest wear Chem-Toughtrade provides a perfect bond to the parent metal
bull Increased HardnessWith an equivalent hardness of Rc 40-60 Chem-Toughtrade is approximately le-hard ndash the hardness of nitrated steel Because the Chem-Toughtrade surface becomes an integral part of the metal it simply cannot peel or chip ndash neither can it bescratched aked or nicked under ordinary conditions
bull Permanent Dry LubricityBy infusing polymers into aluminum Chem-Toughtrade gives the resulting surface a high degree of permanent lubricity and resistance to moisture The polymers also level o surface asperities signicantly reducing surface tension The result blowers converted with Chem-Toughtrade have a longer life operate more eciently and call for less maintenance
bull Other Proprietary ProcessesFood-Toughtrade uses the same unique process as Chem-Toughtrade and is designed for the food processing medical andpharmaceutical markets Food-Toughtrade has USDA approval and meets FDA guidelines
Chem-Toughtrade at Work
Chem-Toughtrade employs the advantages of anodizing hardcoat plating low-friction polymers and dry lubricants to become an integral part of the blowerrsquos molecular structure
Specically Chem-Toughtrade rst converts the aluminum surface to aluminum oxide forming a new ceramic-like surface The water in the ceramic is replaced with Teonreg adding a multi-functional dimension to the surface in the process the aluminum crystals expand and form anchor crystals that remain hygroscopic for a short time Then under controlled conditions particles of the specied polymer are infused to interlock with these anchor crystals The new surface extends 5 mil above and below the original aluminum surface ndash and forms a permanent molecular bond with the metal
The result a plasticceramic surface thatrsquos harder than steel is continuously lubricating and resists damage from chemicals like no other The kind of protection you need for your chemical processing blowers
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Acetaldehyde B C A A A A AAcetate Solv B B A A A B A B Acetic Acid B D C A B A B AAcetic Anhydride B B D A B A A B AAcetone A A A A A A A B AAcetylene A A A A A A A Acrylonitrile B C A A C BAlcohols
Amyl C C C A A A A ABENZYL B A A AButyl B C C A A A A ADiacetone A A A A AEthyl B A A A A A AHexyl A A A A AIsobutyl B A A A AIsopropyl B C A A A AMethyl B A A A A A A AOctyl A A A A APropyl A A A A A A
Aluminum Chloride 20 B D A D C D AAluminum Chloride D D B A C D C AAluminum Hydroxide A D A A A A A Alum Potassium
Sulfate (Alum) 10 A D A A A BAlum Potassium
Sulfate (Alum) 100 B A A D A B BAluminum Sulfate A D A A C C A AAmines A A B A A A A AAmmonia 10 A A AAmmonia Anhydrous B D B A A B A A AAmmonia Liquids D A A A A A A BAmmonia Nitrate C A A A A Ammonium Biuoride D C A BAmmonium Carbonate C C B A B A A A BAmmonium Chloride C D D A C A C A AAmmonium Hydroxide C A C A A A A A AAmmonium Nitrate B A D A A A A A AAmmonium Persulfate C D A A A A A AAmmonium Phosphate Dibasic A A A AB D A BAmmonium Phosphate Monobasic A A A AB A A Ammonium Phosphate Tribasic A A A AB C D A BAmmonium Sulfate B C C A C A B A AAmyl-Acetate B C A B A A C AAmyl Alcohol B A A A A AAmyl Chloride D A A C B AAniline C C A B A A A BAnti-Freeze A B C A A A AAntimony Trichloride D A D D AAromatic Hydrocarbons A A A A Arsenic Acid D D D A B A A
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Barium Carbonate B B B A B A A A ABarium Chloride D D C A C A A A ABarium Hydroxide D C C A B C A A BBarium Sulfate D C C A B A A A ABarium Sulde D C C A B A A Benzaldehyde B B A A A A A ABenzene B B C A B A A A BBenzoic Acid B D A B A A A ABenzol B A A A ABorax (Sodium Borate) C A C A A A A ABoric Acid B D A B A A A ABromine (Wet) D D D A D D D D AButadiene A C C A A A A Butane A C C A A A A Butanol A A A A AButylene A A A A A A Butyl Acetate A A A C AButyric Acid B D A B B A A ACalcium Bisulfate D D A C D A Calcium Bisulde C A B ACalcium Bisulte C A D A ACalcium Carbonate C D A B A A A ACalcium Chloride C C A C A D C ACalcium Hydroxide C A B A A ACalcium Hypochlorite C D A D A C C BCalcium Sulfate B A B A A A BCarbon Bisulde A B B A A A Carbon Dioxide (Wet) C C A A A ACarbon Disulde C B C A B A Carbon Monoxide A A A Carbon Tetrachloride C C D A B C B A ACarbonated Water A D B A A A Carbonic Acid A D A B A B A AChloracetic Acid C D A D D D D AChlorinated Glue D D A A
D C A D D D AChlorine Anhydrous LiquidChlorine (Dry) D A A B A A AChlorine Water D D A D D BChlorobenzene (Mono) B B C A A A A AChloroform D D C A A A A A AChlorosulfonic Acid D D A D D D BChlorox (Bleach) C D C A A A AChromic Acid 5 C D A A B AChromic Acid 50 C D A C B B ACitric Acid C D A A A A ACitric Oils C A A Copper Chloride D D A C D D B ACopper Cyanide D D A A A A ACopper Floborate D D A D D BCopper Nitrate D A B A A B A
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical
Chemical Resistance Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Copper Sulfate (5 Solution) A A A AD D A AABsloserCBAABACdicA cilyserCAAAenaxeholcyCAAAAstnegreteDAAAAAAleuFleseiDAAAAenimalyhteiDAAB
A BseyD
Epsom Salts (Magnesium Sulfate) A A A BAAAenahtE
E the Ar B A A A A BBAAACBetatecA lyhtE
ADCBC C C A A A BD C A A A BA B C A A A AA A A
edirolhC lyhtE A A A BEthylene ChlorideEthylene DichlorideEthylene GlycolEthylene Oxide
AAAADBsdicA yttaFBDDDADDedirolhC cirreF
Fer ric Nit rat De A A A A AAACAADD
D D A D D BD D D A B A C B
etafluS cirreFFerrous ChlorideFerrous Sulfate
ADDDCDDDeniroulFBBADDdicA cicilisoulFBAAAAADAedyhedlamroF
CADDDdicA cimroF A B B AAAABCB
B A D 11 noerF
Freon 12 (Wet)AB22 noerFAB311 noerFABFT noerFAAAAABCAsliO leuFAAAAAAniseR naruFBAAAAAAlarufruFAAABADDAdicA cillaG
AAAAAenilosaG A A A AAABBAenirecylG A A A A
AAAABAenatpeHAAAAABA
A A A A A A A A A A A D D D A D D D D AD D A D C A AD D A D D D BD D A D D D BD D A D D CA C A A A A C AD D A D D D BD D A C D C
enaxeHHydraulic Oils (Petroleum)Hydraulic Oils (Synthetic)Hydrobromic AcidHydrochloric Acid (Dry Gas)Hydrochloric Acid (20)Hydrochloric Acid (37)Hydrochloric Acid 100Hydrocyanic AcidHydrouoric Acid (20)Hydrouoric Acid (75)
Hydrouoric Acid 100 D D D A D D D BD D A D D BHydrouosilicic Acid (20)
Hydrouosilicic Acid C A D D CHydrogen Gas A B B A A A A Hydrogen Peroxide 10 A D A C C AHydrogen Peroxide A D D A A B A AHydrogen Sulde
Aqueous Solution C D A A A C AHydrogen Sulde (Dry) D B B A A C A AHydroxyacetic Acid (70) D Ink C D D A A A Iodine D D A D D D BIodoform A C B A B D A Isotane A Isopropyl Acetate C B Isopropyl Ether A A A A A Jet Fuel (JP3 JP4 JP5) A A A A A A A Kerosene A A B A A A A A AKetones B A A A A A A ALacquers A C C A A A Lactic Acid C D D A A A B C ALead Acetate D D A B A A ALubricants A A A A AMagnesium Chloride D D C A B B B A AMagnesium Hydroxide D B B A A A A AMagnesium Sulfate B C B A B B A BMaleic Acid B B A C A A A AMalic Acid C D A B A A A
D D D A D D D D BMercuric Chloride (Dilute Solution)Mercuric Cyanide D D A A A A Mercury C A A A A A A A AMethane A A A A A A A A AMethyl Acetate A B A A A AMethyl Acetone A A A A A A Methyl Alcohol 10 C B A A A AMethyl Butyl Ketone A A Methyl Cellosolve A Methyl Chloride D A C A AMethyl Ethyl Ketone A A A A AMethylamine A B B A A Methylene Chloride A B A A A A ANaptha A B B A A A A A ANapthalene B B A A B A B ANickel Chloride D D A A B ANickel Sulfate D D D A B A B BNitric Acid (10 Solution) D D D A A A A A ANitric Acid (20 Solution) D D A A A A ANitric Acid (50 Solution) D D A
B D A D B A B
A A A ANitric Acid
(Concentrated Solution)
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Motor Blower Options
Chemical Resistance Chart (Contrsquod)
Nitrobenzene C B B A B A B BOleum B B A B A Oxalic Acid (cold) C D D A C A B A BPentane A B B A A C C BPerchloroethylene A B B A B A A Petrolatum B C C A A A Phenol 10 A B D A B A A BPhenol (Carbolic Acid) B D D A B A A A APhosphoric Acid
(to 40 Solution) D D A B A A APhosphoric Acid
(40-100 Solution) D D A C B B APhosphoric Acid (Crude) D D D A D C C A
D A A A Phosphoric Anhydride (Molten)Photographic (Developer) C D C A C APhthalic Anhydride B C C A B A B APicric Acid C D D A B A A APotash C B A A APotasium Bicarbonate C D A A B BPotassium Bromide C D D A A A B BPotassium Carbonate C B B A B A A APotassium Chlorate B B B A B A A A BPotassium Chloride B B B A C A A B APotassium Chromate A A B B B
D B B A BPotassium Cyanide Solutions A B A APotassium Dichromate A B C A B A A A BPotassium Ferrocyanide C C A B A A B
D C A A APotassium Hydroxide (50) B B B APotassium Nitrate B B A B A B A BPotassium Permanganate B B B A B A B B BPotassium Sulfate A B B A B A B B APotassium Sulde B B B A A A A BPropane (Liquied) A B A A A A Propylene Glycol A B B A B B A Pyridine B B A A C B Pyrogallic Acid B B B A B A A A ASilver Bromide D C C B Silver Nitrate D D D A B A B A ASodium Acetate B C C A B A A B ASodium Aluminate C C A B A BSodium Bicarbonate A C C A B A A A Sodium Bisulfate D D D A A A A BSodium Bisulte A D A A A BSodium Borate C C C A B A A ASodium Carbonate C B B A B A B B ASodium Chlorate B C A B A A BSodium Chloride C B C A B A C B ASodium Chromate D B B A A A A BSodium Cyanide D B B A B A A Sodium Fluoride C D D A B C C A
Sodium Hydrosulte A A ASodium Hydroxide (20) D A A
D B A A B AD C A A D BD C A A D B
A A A ASodium Hydroxide (50 Solution)Sodium Hydroxide (80 Solution)Sodium Hypochlorite (to 20)Sodium Hypochlorite D D D A D A ASodium Hyposulfate D A A A Sodium Metaphosphate A B B A A A Sodium Metasilicate B C C A A A Sodium Nitrate A A B A B A A A BSodium Perborate B B B A B C Sodium Peroxide C D C A B A A BSodium Polyphosphate
(Mono Di Tribasic) D A A A ASodium Silicate C B A B A B A BSodium Sulfate B A B A B A A C BSodium Sulde D A B A B A B BSodium Sulte C A A C C A
B C B A A A A Sodium Thiosulphate (ldquoHypordquo)Stannic Chloride D D D A D D D BStannous Chloride D D D A D D C AStearic Acid B C C A B A A A AStoddard Solvent A B B A A A A A AStyrene A A A A A A Sulfate Liquors B C C ASulfur Chloride D A D D D Sulfur Dioxide A A A A C BSulfur Dioxide (Dry) A A B A A A A ASulfur Trioxide (Dry) A B B A A A C Sulfuric Acid (to 10) C D A D C C ASulfuric Acid (10-75) D D A D D D BSulfurous Acid C D D A C C B C BTannic Acid C C C A B A A A BTanning Liquors C A A A ATartaric Acid C D D A B A B B BTetrahydrofuran D D A A A A Toluene Toluol A A A A A A A ATrichlorethane C C A C A ATrichlorethylene B C B A B A A AWater Acid Mine C C A A
B D A A A Water Distilled Lab Grade 7Water Fresh A B D A A A A Water Salt B D A A Weed Killers C A A Whiskey and Wines D D D A A A A A Xylene A A B A A A A AZinc Chloride D D D A D A B B BZinc Hydrosulphite D D A Zinc Sulfate D C D A B A A A B
Chemical Eect RatingsA ndash No eect ndash acceptableB ndash Minor eect ndash acceptableC ndash Moderate eect ndash questionableD ndash Severe eect ndash not recommended ndash Not tested
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Alum
inum
Cast
Iron
Carb
on S
teel
Chem
-Tou
gh (T
eon
reg)30
2 St
ainl
ess
Stee
l
304
Stai
nles
s St
eel
316
Stai
nles
s St
eel
440
Stai
nles
s St
eel
Has
tello
y C
Chemical Chemical
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 H 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Flow
bull Volume RateTimebull ROTRON charts are in SCFM m3min or LSbull SCFM = Standard Cubic Feet Per Minute (American) where
temperature = 68degF air density = 0075 lbcubic foot and altitude = 0 feet above sea level
bull M3min = Cubic Meters Per Minute (Metric)bull Lsec = Liters Per Second (Metric)bull 1 m3min = 353 SCFMbull 1 Lsec = 2119 SCFMbull See Standard Engineering Conversions for other flows on
pg I-2
Throughout our catalog you will find terminology used for air moving selection and product sizing Below are a few of the key terms
Specic Gravity
bull Density Ratio Relative to Airbull Standard Air SG = 10bull Methane SG = 055bull See Specific Gravity Chart for other gases on pg I-4
Pressure
bull ForceAreabull ROTRON charts are in IWG PSIG MM of Water IHG or mbarbull IWG = Inches of Water Gauge (American)bull PSIG = Pounds Per Square Inch Gauge (American)bull MM of Water = Millimeter of Water Gauge (Metric)bull IHG = Inches of Mercury Gauge (American)bull mbar = Millibar Gauge (Metric)bull PSIA = Pounds Per Square Inch Absolute (American)bull 277 IWG = 1 PSIGbull 70358 MM of Water = 1 PSIGbull 2036 IHG = 1 PSIGbull 0069 Bars = 69 mbar = 1 PSIGbull Standard Atmosphere = 0 PSIG = 147 PSIAbull See Basic Fan Laws Chart for correcting pressure due to speed
or density changes on pgs I-5 and I-6
Density
bull WeightVolumebull Standard Air = 0075 lbcubic footbull See Density Chart for other gases on pg I-4bull See Density Correction Chart due to altitude and temperature
changes on pg I-3
Velocity
bull DistanceTime or FlowAreabull FPM = Feet Per Minute (American)bull MPH = Miles Per Hour (American)bull Mmin = Meters Per Minute (Metric)bull Kmh = Kilometers Per Hour (Metric)bull 88 FPM = 1 MPHbull 2682 Mmin = 1 MPHbull 1609 Kmh = 1 MPHbull See Standard Engineering Conversion Chart for other
velocities on pg I-2bull See Orifice Flow Calculation Chart for air flow equations on
pg I-7
Pressure Drop Back Pressure Impedance
bull Friction causes air to slow down and lost energy is measured in pressure drop terms
bull Typical pressure drop areas include piping elbows accessories and system
bull Each fixed system has a fixed system impedance caused by a single or multiple pressure drop points
bull Changing the system impedance will cause blowers work point to change
bull Changing the blower with fixed system impedance will change the working back pressure
bull See Friction Loss Per Foot of Tubing and Fitting Charts on pg I-8
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 1Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Engineering Conversion
MULTIPLY BY TO OBTAINAtmospheres 760 Cms of MercuryAtmospheres 2992 Inches of MercuryAtmospheres 3390 Feet of WaterAtmospheres 10333 KgsSq InchAtmospheres 1013 x 105 PascalsAtmospheres 1470 PoundsSq InchAtmospheres 760 TorrsBars 09869 AtmospheresBars 1 x 106 DynesSq CmBars 1020 x 104 KgsSquare MeterBars 1450 PoundsSq InchBritish Thermal Units 02520 Kilogram-CaloriesBritish Thermal Units 7775 Foot-PoundsBritish Thermal Units 3927 x 10-4 Horsepower-HoursBritish Thermal Units 1054 JoulesBritish Thermal Units 1075 Kilogram-MetersBritish Thermal Units 2928 x 10-4 Kilowatt-HoursCentimeters of Mercury 001316 AtmospheresCentimeters of Mercury 04461 Feet of WaterCentimeters of Mercury 1360 KgsSquare MeterCentimeters of Mercury 01934 PoundsSq InchCentimetersSecond 1969 FeetMinuteCentimetersSecond 06 MetersMinuteCubic Centimeters 3531 x 10-5 Cubic FeetCubic Centimeters 6102 x 10-2 Cubic InchesCubic Centimeters 10-6 Cubic MetersCubic Centimeters 10-3 LitersCubic Feet 2832 x 104 Cubic CmsCubic Feet 1728 Cubic InchesCubic Feet 002832 Cubic MetersCubic Feet 003704 Cubic YardsCibic Feet 7481 GallonsCubic Feet 2832 LitersCu Ft of Water (60degF) 6237 PoundsCubic FeetMinute 4720 Cubic CmsSecCubic FeetMinute 04720 LitersSecondCubic FeetMinute 624 Lbs of WaterMinCubic Inches 1639 Cubic CentimetersCubic Inches 5787 x 10-4 Cubic FeetCubic Inches 1639 x 10-5 Cubic MetersCubic Inches 2143 x 10-5 Cubic YardsCubic Meters 106 Cubic CentimetersCubic Meters 3531 Cubic FeetCubic Meters 61023 Cubic InchesCubic Meters 1308 Cubic YardsCubic Yards 7646 x 105 Cubic CentimetersCubic Yards 27 Cubic FeetCubic Yards 46656 Cubic InchesCubic Yards 07646 Cubic MetersFeet 3048 CentimetersFeet 12 InchesFeet 03048 MetersFeet 13 YardsFeet of Air
(1 atmosphere 60degF) 530 x 10-4 PoundsSquare InchFeetMinute 05080 CentimetersSecFeetMinute 001667 FeetSecondFeetMinute 001829 KilometersHourFeetMinute 03048 MetersMinuteFeetMinute 001136 MilesHourGramsCu Cm 6243 PoundsCubic FootHorsepower 4244 British Thermal UnitsMinHorsepower 33000 Foot-PoundsMinHorsepower 1070 Kg-CaloriesMinHorsepower 7457 WattsHorsepower-Hours 2547 British Thermal UnitsInches 2540 CentimetersInches 103 MilsInches of Mercury 003342 AtmospheresInches of Mercury 1360 Inches of WaterInches of Mercury 3453 KgsSquare MeterInches of Mercury 2540 Mms of MercuryInches of Mercury 04912 PoundsSquare InInches of Water 0002458 AtmospheresInches of Water 007355 Inches of MercuryInches of Water 2540 KgsSquare MeterInches of Water 5204 PoundsSquare FtInches of Water 003613 PoundsSquare In
MULTIPLY BY TO OBTAINKGSCubic Meter 006243 PoundsCubic FootKilometers 3281 FeetKilowatts 5692 British Thermal UnitsMinKilowatts 7376 Foot-PoundsSecKilowatts 1341 HorsepowerKilowatts 1434 Kg-CaloriesMinKilowatt-Hours 3415 British Thermal UnitsLiters 103 Cubic CentimetersLiters 6102 Cubic InchesLiters 10-3 Cubic MetersLog10N 2303 LogEN or Ln NLog N or Ln N 04343 Log10NMeters 100 CentimetersMeters 32808 FeetMeters 3937 InchesMeters 10-3 KilometersMetersMinute 1667 CentimetersSecMetersMinute 3281 FeetMinuteMetersMinute 006 KilometersHourMetersMinute 003728 MilesHourMiles 5280 FeetMiles 16093 KilometersMiles 1760 YardsMilesHour 4470 CentimetersSecMilesHour 88 FeetMinuteMilesHour 1467 FeetSecondMilesHour 16093 KilometersHourMilesHour 2682 MetersMinuteMms of Mercury 00394 Inches of MercuryMms of Mercury 13595-3 KgsSquare CmMms of Mercury 001934 PoundsSquare InchPints (Liq) 2887 Cubic InchesPints (US liquid) 473179 Cubic CentimetersPints (US liquid) 16 Ounces (US fluid)Pounds 444823 DynesPounds 4536 GramsPounds 16 OuncesPounds of Carbon to CO2 14544 British Thermal Units (mean)Pounds of Water 2768 Cubic InchesPounds of Water 01198 GallonsPounds of Water
Evaporated at 212degF 9703 British Thermal UnitsPoundsCubic Foot 1602 KgsCubic MeterPoundsSquare Foot 4882 KgsSquare MeterPoundsSquare Inch 006804 AtmospheresPoundsSquare Inch 277 Inches of WaterPoundsSquare Inch 2036 Inches of MercuryPoundsSquare Inch 7031 KgsSquare MeterPoundsSquare Inch 6895 x 103 PascalsPoundsSquare Inch 51715 Millimeters of Mercury at 0degCSquare Centimeters 1973 x 105 Circular MilsSquare Centimeters 1076 x 10-3 Square FeetSquare Centimeters 01550 Square InchesSquare Feet 9290 Square CentimetersSquare Feet 009290 Square MetersSquare Inches 1273 x 106 Circular MilsSquare Inches 6452 Square CentimetersSquare Inches 6944 x 10-3 Square FeetSquare Inches 106 Square MilsSquare Inches 6452 Square MillimetersSquare Kilometers 1076 x 106 Square FeetSquare Kilometers 106 Square MetersSquare Kilometers 1196 x 106 Square YardsSquare Meters 10764 Square FeetSquare Meters 1196 Square YardsTemp (Degs C) + 273 1 Abs Temp (Degs C)Temp (Degs C) + 178 18 Temp (Degs Fahr)Temp (Degs F) + 460 1 Abs Temp (Degs F)Temp (Degs F) -32 59 Temp (Degs Cent)Watts 005692 British Thermal UnitsMinWatts 107 ErgsSecondWatts 4426 Foot-PoundsMinWatts 1341 x 10-3 HorsepowerWatts 001434 Kg-CaloriesMinWatts 10-3 KilowattsWatts-Hour 3415 British Thermal UnitsWatts-Hour 1341 x 10- HorsepowerHoursWatts-Hour 10-3 Kilowatt-Hours
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 2Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Density Correction Chart
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 3Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Specic Gravity and Density of Various Gases at 60degF (1 ATM)
ChemicalFormula
Density(lbscu ft)
Gas or Vapor Specic Gravity
Acetylene 0899 0686Air 100 0763Ammonia 0587 0454Argon 1377 1053Benzene 270 205Carbon Dioxide 1539 1166Chlorine 2448 0738Ethane 1038 0799Ethylene 0969 0739Helium 0138 01054Hydrogen 00695 00531Hydrogen Sulde 119 0897Methane 0555 0424Methyl Chloride 1785 1356Nitrogen 0967 0738Oxygen 1105 0843Propane 155 1180Sulfer Oxide 226 1720Water Vapor 0622
C2H2
-NH3
AC6H6
CO2
CI2
C2H6
C2H4
HeH2
H2SCH4
CH3CIN2
O2
C3H8
SO2
H2O 0373
Explosive Atmosphere Classication
NEMA Classications
North American European
Class I Zone 1Group A AcetyleneGroup B Group II C
Group II CHydrogen or equivalent hazard
Group C Group II B Ethyle ether vapors ethylene orcyclopropane
Group D Group II A Gasoline hexane naptha benzenebutane alcohol acetone benzol lacquer vapors or natural gas
Class IIGroup E Metal dustGroup F mdash
mdashCarbon black coal or coke dust
Group G mdash Flour starch or grain
Temperature Conversion Chart
degC Temp degF degC Temp degF degC Temp degF degC Temp degF-789 -110 -166 17 35 950 272 81 1778 182 360 680-733 -100 -148 22 36 968 278 82 1796 188 370 698-678 -90 -130 28 37 986 283 83 1814 193 380 716-622 -80 -112 33 38 1004 289 84 1832 199 390 734-567 -70 -94 39 39 1022 294 85 1850 204 400 752-511 -60 -76 44 40 1040 300 86 1868 210 410 770-456 -50 -58 50 41 1058 306 87 1886 216 420 788-400 -40 -40 56 42 1076 311 88 1904 221 430 806-344 -30 -22 61 43 1094 317 89 1922 227 440 824-289 -20 -4 67 44 1112 322 90 1940 232 450 842-233 -10 14 72 45 1130 328 91 1958 238 460 860-178 0 32 78 46 1148 333 92 1976 243 470 878-172 1 338 83 47 1166 339 93 1994 249 480 896-167 2 356 89 48 1184 344 94 2012 254 490 914-161 3 374 94 49 1202 350 95 2030 260 500 932-156 4 392 100 50 1220 356 96 2048 266 510 950-150 5 410 106 51 1238 361 97 2066 271 520 968-144 6 428 111 52 1256 367 98 2084 277 530 986-139 7 446 117 53 1274 372 99 2102 282 540 1004-133 8 464 122 54 1292 378 100 2120 288 550 1022-128 9 482 128 55 1310 43 110 230 293 560 1040-122 10 500 133 56 1328 49 120 248 299 570 1058-117 11 518 139 57 1346 54 130 266 304 580 1076-111 12 536 144 58 1364 60 140 284 310 590 1094-106 13 554 150 59 1382 66 150 302 316 600 1112-100 14 572 156 60 1400 71 160 320 321 610 1130
-94 15 590 161 61 1418 77 170 338 327 620 1148-89 16 608 167 62 1436 82 180 356 332 630 1166-83 17 626 172 63 1454 88 190 374 338 640 1184-78 18 644 178 64 1472 93 200 392 343 650 1202-72 19 662 183 65 1490 99 210 410 349 660 1220-67 20 680 189 66 1508 100 212 413 354 670 1238-61 21 698 194 67 1526 104 220 428 360 680 1256-56 22 716 200 68 1544 110 230 446 366 690 1274-50 23 734 206 69 1562 116 240 464 371 700 1292-44 24 752 211 70 1580 121 250 482 377 710 1310-39 25 770 217 71 1598 127 260 500 382 720 1328-33 26 788 222 72 1616 132 270 518 388 730 1346-28 27 806 228 73 1634 138 280 536 393 740 1364-22 28 824 233 74 1652 143 290 554 399 750 1382-17 29 842 239 75 1670 149 300 572 404 760 1400-11 30 860 244 76 1688 154 310 590 410 770 1418-06 31 878 250 77 1706 160 320 608 416 780 1436
0 32 896 256 78 1724 166 330 626 421 790 145406 33 914 261 79 1742 171 340 644 427 800 147211 34 932 267 80 1760 177 350 662 432 810 1490
In the center column nd the temperature to be converted The equivalent temperature is in the left column if converting to Celsius and in the right column if converting to Fahrenheit
degF = 95C + 32 ABSOLUTE RANKIN (R) R = degF + 460degC = 59 (F - 32) ABSOLUTE KELVIN (K) K = degC + 273
Ref NEMA Standards Publication Pub No 1CSndash1970
NEMA Type 1 ndash General Purpose ndash IndoorType 2 ndash Dripproof ndash IndoorType 3 ndash Dusttight Raintight and Sleet (Ice)
Resistant ndash Outdoor3R ndash Rainproof and Sleet (Ice) Resistant
ndash Outdoor3S ndash Dusttight Raintight and Sleet (Ice)
Proof ndash OutdoorType 4 ndash W atertight and Dusttight ndash Indoor
4X ndash W atertight Dusttight and CorrosionResistant ndash Outdoor
Type 5 ndash Superseded by Type 12 for ControlApparatus
Type 6 ndash Submersible Watertight Dusttight andSleet Resistant ndash Indoor and Outdoor
Type 7 ndash Class I Group A B C or D HazardousLocations Air Break Equipment ndash Indoor
Type 8 ndash Class I Group A B C or D Hazardous Locations Oil-immersed Equipment ndash Indoor
Type 9 ndash Class II Group E F or G HazardousLocations Air-break Equipment ndash Indoor
Type 10 ndash Bureau of MinesType 11 ndash Corrosion Resistant and Dripproof
Oil-immersed ndash IndoorType 12 ndash Industrial Use Dusttight and Driptight
ndash IndoorType 13 ndash Oiltight and Dusttight ndash Indoor
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 4Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Physical Laws for Blower Applications
In the following formulae these symbols are used
P ndash Pressure in pounds per square inch (PSI) or inches ofmercury column (inches Hg)
CFM ndash Volume in cubic feet per minuteRPM ndash Speed in revolutions per minuteD ndash Density in pounds per cubic foot (lbscu ft)H ndash Height of air or gas column (ft)SG ndash Specic Gravity (ratio of density of gas to the density
of air)
ldquoStandard Airrdquo ndash Air at 68degF (absolute temperature 528deg) and 2992rdquo Hg (barometric pressure at sea level) The density of such air is 0075 lbscu ft and the specic volume is 1329 cu ftlb The specic gravity is 10
The outlet pressure of a blower depends on the condition of the air or gas at the inlet The inlet condition is inuenced bya ndash Specic gravity (The ratio of density of the gas to density of
standard air)b ndash Altitude (location of blower)c ndash Temperature of inlet air
Volume
Pressure
The Volume changes in direct ratio to the speedExample ndash A blower is operating at 3500 RPM and delivering 1000 cfm If the speed is reduced to 3000 RPM what is the new volume
Basic Fan Laws Chart
V REWOPESROHERUSSERPEMULOVELBAIRA
WHEN SPEED CHANGES Varies DIRECT with Speed Ratio Varies with SQUARE of Speed Ratio
Varies DIRECT with Density Ratio Varies DIRECT with Density Ratio
Varies with CUBE of Speed Ratio
CFM 2 = CFM 1 ( RPM 2 ) P 2 = P 1 ( RPM 2 )2 HP 2 = HP 1 ( RPM 2 )3
RPM 1 RPM 1 RPM 1
WHEN DENSITY CHANGES Does Not Change
P 2 = P 1 ( D2 ) HP 2 = HP 1 ( D2 )D1 D1
V 1 = Original Volume (1000 CFM)V 2 = New VolumeRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
V 2 = V 1 ( RPM 2 )1= 1000 x ( 3000 )1
= 1000 x 857 = 857 CFMRPM 1 3500
Pressure (barometric) varies in direct proportion toaltitudeExample ndash A blower is to operate at an elevation of 6000 feetand is to deliver 3 PSI pressure What pressure (standard air)blower is required
Pressure = 3 x 2992
= 375 or 3 34 lb2398
If it is desired to determine what pressure a 3 lb (standard air)blower will deliver at 6000 feet ndash
Pressure = 3 x 2398
= 24 or about 2 12 lb2992
When a blower is to operate at a high altitude it is frequentlyspecied that the blower be capable of handling a given vol-ume of ldquostandard airrdquo It is then necessary to determine theequivalent volume of air at the higher altitudeExample ndash A blower is to operate 6000 feet altitude and is tohandle 1000 CFM of standard air What is the CFM of air theblower must handle at 6000 feet altitude
Let V 1 = Volume of standard air (1000 CFM)V 2 = Volume of thinner airHg1 = Barometric pressure sea level (2992)Hg2 = Barometric pressure 6000rsquo (2398)
V 2 = V 1 x Hg
1 = 1000 x 2992
= 1248 CFMHg 2 2398
The pressure changes as the square of the speed ratio
Example ndash A blower is operating at a speed of 3500 RPM anddelivering air at 50 pounds pressure If the speed is reduced to3000 RPM what is the new pressure
P 1 = Original Pressure (5 lbs)P 2 = New PressureRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
P 2 = P 1 ( RPM 2 )2= 5 x ( 3000 )2
= 5 x 735 = 368 poundsRPM 1 3500
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 5Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Pressure (Contrsquod)
Horsepower
The Air Density varies in inverse proportion to theabsolute temperatureExample ndash A blower is to handle 200degF air at 3 PSI pressureWhat pressure (standard air) blower is required
Let P 1 = Pressure hot air (3 PSI)P 2 = Pressure standard airAT 1 = Absolute temperature hot air (200+460=660degF)AT 2 = Absolute temperature standard air (68+460=528degF)
P 2 = P 1 x AT
1 = 3 x 660 = 375 or 3 34 lbAT 2 528
A blower is capable of delivering 3 PSI pressure with standardair What pressure will it develop handling 200degF inlet air
P 1 = P 2 x AT
2 = 3 x 528 = 24 or about 2 12 lbAT 1 660
Pressure varies in direct proportion to the densityExample ndash A 3 lb (standard air) blower is to be used to handlegas having a specic gravity of 05 What pressure does theblower create when handling the gas
Let Pa = Air pressure (3 lb)Pg = Gas pressureSG = Specic gravity of gas (05)
Pg = Pa x SG = 3 x 5 = 15 lb
If we are required to handle a gas having a specic gravity of 05at 15 lb pressure we can determine the standard air pressureblower as follows
Let Pa = Pg
= 15
= 3 lbSG 5
The following table gives the barometric pressure of various altitudesAbsolute Pressure At Altitudes Above Sea Level (Based on US Standard Atmosphere)
Altitude
0500
Feet In Hg PSIA Feet In Hg PSIA Feet In Hg PSIA
600700800900
100015002000
299229382928291829072897288628332782
147014431438143314281423141813901367
250030003500400045005000550060006500
273126812632258425362489244323982353
134113191292127012451223120011771156
700075008000850090009500
10000
2309226522222180213820982058
1134111210901070105010901010
Pressure Altitude Pressure Altitude Pressure
The horsepower changes as the cube of the speed ratioExample ndash A blower is operating at a speed of 3500 RPM andrequiring 50 horsepower If the speed is reduced to 3000 RPMwhat is the new required horsepower
HP 1 = Original Horsepower (50)HP 2 = New HorsepowerRPM 1 = Original Speed (3500 RPM)RPM 2 = New Speed (3000 RPM)
HP 2 = HP 1 x (RPM 2)3= 50 x (3000 )3
= 50 x 630 = 315 horsepowerRPM 1 3500
The above is known as the 1-2-3 rule of blowers
Horsepower vs Specic Gravity amp Ratio of densityThe horsepower varies in direct proportion to the specic gravity(ratio of density of gas to density of air)Example ndash A standard air blower requires a 10 HP motor Whathorsepower is required when this blower is to handle a gaswhose specic gravity is 05
HP = 10 x 05 = 5 horsepower
It is possible that several of the above modications may berequired on one installation Therefore it may be necessary touse various combinations of these formulae
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 6Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Orice Flow
Orice Flow CalculationTo determine air ow through an orice
V = CK radic P Q = AV VP = ( V ) 2K
WhereV = V elocity in feet per minute (fpm)C = Orice CoecientK = Constant = 14786 when P is expressed
in In Hg21094 when P is expressedin PSIG4005 when P is expressedin In of Water
(Above constants are based on an air densityof 0075 lbsft 3)
P = Pressure dierential across the oriceQ = Flow rate in cubic feet per minute (CFM)A = T otal orice area expressed in square feetVP = Velocity pressure (units are those of pressure)
Coecient C for Orices UnderVacuum or Pressure Flow
Area of OricesOrice Diameter in Inches
Diameterin Inches Square Inches Square Feet
18 01227 000085316 02761 0001914 04908 0003438 11044 0007612 19634 0013658 30679 0021378 60132 0041710 78539 00545
Orice area (in sq inches) = 25 X π X (orice diameter in inches) 2
Orice area (in sq feet) = Area in sq inches divide 144
ORIFICE PRESSURE DROP AS A FUNCTIONOF FLOW AND ORIFICE AREA (C=65)
c-98 c-92 c-82 c-80
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
Pres
sure
Dro
pIn
ches
of W
ater
c-72 c-65 c-80 c-53
15
30
45
60
75
90
105
120
135
150
20
40
60
80
100
120
140
160
180
20
0 100 200 300Flow Rate SCFM
400 500
500 700 900 1100Flow Rate SCFM
1300 1500
1500 1700 1900 2100Flow Rate SCFM
2300 2500
40
60
80
100
200
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 7Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Friction Loss Per Foot of Tubing
Friction Loss in Fittings
To calculate friction loss in ttings use chart below This chart will yield equivalentlengths (in feet) of tubing Use this length with graph above to nd friction loss ininches of water column
NOMINAL PIPE SIZE (INCHES) EQUIVALENT TUBING LENGTH (FEET)
90deg EL 45deg EL
1 14 3 151 12 4 2
52 252 12 6 3
47314 0 515 2 616 5 7528 0 10
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 8Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Noise Facts
Loudness Levels of Familiar Noises (Approximate Average Including Ear Nework)
bull OSHA (Occupational Safety amp Health Administration) regulates and monitors in-plant noisebull Allowable noise is a function of dBA level at certain distance over an exposure timebull OSHA regulations state 90 dBA for an 8 hour work period using slow responic setting on meterbull Adding a second noise producer of equal dBA will add 3 dBA to the first dBA readingbull Sound pressure level (SPL) decreases with distance (d)
(SPL) 2 = (SPL) 1 - 20LOG ( d2 )d1
Therefore each doubling of distance results in 6 dBA reduction
Threshold of Painful Feeling
Airplane and Propeller at 10
Ft
Train Passing at High Speed
Riveter at 30 Ft Auto Horn at 20 Ft Pneumatic Drill at 10 FtSubway TrainFire Siren at 75 Ft Noisy Street RailwayNoisy StreetPolice Whistle at 15 Ft Auto at 60 MPH
Very Noisy Restaurant Auto at 40 MPH Average Stenographic Room
Factories Auto at 20 MPHNoise in Pullman (Windows Shut)Noisy OfficeAverage RestaurantDept Store Average Conversation at 3 FtAverage Office Quiet Street Noisy ResidenceQuiet Restaurant Quiet OfficeMuseumAverage School Average Residence Motion Picture Theater Library Reading Rooms AuditoriumsAverage Whisper at 5 Ft Very Quiet Residence
Broadcasting Studio Zero of AIEE Scale 14 Db
Zero of Original Scale 85
Db Threshold of Audibility
1013 130
1012 120
1011 110
1010 100
109 90
108 80
107 70
106 60
105 50
104 40
103 30
102 20
10 10
1 1
Loud
ness
Lev
els
in D
ecib
els
Rel
ativ
e In
tens
ities
(Int
ensi
ty A
bove
Thr
esho
ld =
10
16 w
atts
per
sq
cm
)
A P
P R
O X
I M
A T
E
N O
I S
E
L E
V E
L S
DEAFENING
NOISY
AVERAGE
QUIET
VERY QUIET
SOUND PROOFR OOMS
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 91258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Industrial Blower Noise Chart in dBA
dBA at Distance Conversion Chart
Average at 1 meter 4 places around the blower
Mode
Suction
SEMFRDCSL2SL4SL5
60-6264-6576-7869-7272-7876-79
60-6264-6576-7869-7272-7876-79
101202303353404454
65-6767-6965-6772-7373-7476-77
66-6868-7067-6973-7474-7575-76
5135055235556566
80-8177-7882-8380-8182-8385-86
80-8176-7782-8380-8182-8385-86
757808633S7858833
83-8584-8581-8288-8984-8582-84
84-8684-8581-8288-8984-8582-84
SP 99091233SP 13
14SP 15
90-9181-8284-8587-8886-8791-92
90-9184-8684-8590-9186-8791-92
Pressure Suction Pressure Suction Pressure Suction Pressure Suction Pressure
Mode Mode Mode ModeModel Model Model Model Model
To read use straight edge to connect blower distance and dBA rating A pivot point A will be developed Use straight edge again with new distance and pivot point A to read dBA at new distance
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 101258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference
Special Features 0 to 4 letters- see gure 2
Voltage Code up to 3 numbers - see gure 1
Motor Description - see gure 3(TEFC XP Chem and ODP)
Describes which family the unit belongs to 1 to 3 numbers
Option for duplex units onlyP = Parallel congurationS = Series conguration
DR = Domestic RegenerativeEN = EnvironmentalCP = Chemical ProcessHiE = Hi Eciency Motor
Figure 1 Voltage Code
Figure 2 Special Features
This chart explains the nomenclature behind the catalogued blower model names This tool can be used to explainto customers what the letters and numbers mean and will also allow you to become familiar with our model namesThis information should not aect the way orders are placed please continue to use the model names shown inthe catalog and price pages Any special request should be noted on the order
5 230 VAC 60 Hz Single Phase9 115230 VAC 5060 Hz Single Phase33 230 VAC 60 Hz Three Phase58 115230 VAC 60 Hz Single Phase60 200 VAC 5060 Hz Single Phase72 230460 VAC 60 Hz Three Phase75 380 VAC 50 Hz Three Phase86 575 VAC 60 Hz Three Phase89 200-230460 VAC 60 Hz Three Phase91 230460 VAC 5060 Hz Three Phase92 415 VAC 50 Hz Three Phase201 380 VAC 60 Hz
A SPECIAL (not covered by any other letter)BC Blower on pressure onlyD Blower on suction onlyEFGH Vapor recovery service - hydrocarbonJ Nasty Gas face sealKL Lo leak option (lip seal)M Die Cast or muer extensionPQR Chem-Toughtrade constructionS Special manifoldTUV V alveW Rail mounted blowerX Base mounted blowerY Slip on angeZ Package blower coupling driveAA Package blower belt drive simplexBB Package blower drive belt duplexRD Remote driveNT No Tower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 11Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Standard Regenerative Blower Nomenclature Reference (Contrsquod)
HP Motor ThermalType Protection
HP Motor ThermalType Protection
Figure 3 Motor Description
DEFKMRVWXYADAEAGAKALARASAWAXAYBABBBCBDBEBGBHBKBLBMBPBQBRBXCBCCCD
CJCKCRCSCTCUDCDJDWDXEEEZFAFBFDFEFFFGFHFJFKFLFMFNFQFRFSFUFWFXFYFZGAGBGCGD
RD
25404030201018
11630306015121434255
75101530551412101520305055751015203020
XPTEFC
CHEM TEFCCHEMTEFCCHEM TEFCCHEM TEFC
TEFCTEFCTEFC
XPODP
CHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFCCHEM TEFC
XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XPCHEM XP
YesNoNoNoNoNoYesYesNoYesNoNoNoNoNoNoNoNoNoNoNoYesNoNoYesYesYesYesYesYesYesYesYesYesYesNo
50505030301515157513131212121010202020757510101015152020152030403414141425
TEFCODPXP
TEFCXP
TEFCODPXP
ODPTEFC
XPTEFC
XPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCODPXP
TEFCXP
TEFCXP
ODPODPODPODPTEFCTEFCODPXP
TEFC
NoNoYesNoYesNoYesYesNoNoYesNoNoYesNoYesNoYesYesNoYesNoNoYesNoYesNoYesNoNoNoNoNoNoYesYesNo
CHEM TEFCTEFC
Remote Drive - No MotorGE 115 No
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 12Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Corrosion-Resistant and Sanitary Blowers Application Data Sheet
To obtain Application Engineering assistance or a quotation for your specific need please photocopy thisform fill out as much as possible and fax it back to Rotron We look forward to working with you
COMPANY
CONTACT
ADDRESS
ADDRESS
ZIPS TAT EC IT Y
FAXP HONE
GAS CONCENTRATION DESCRIPTIONPercentage Gas Specific Gravity
________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )________ _______________ (SG =
_______ ) ________ _______________
(SG = _______ )___ __ _______________ (SG = _______ )
Corrosive Yes No Explosive Yes NoGAS
CLASSIFICATION
AREA
CLASSIFICATION
Corrosive Yes No Explosive Yes No
PERFORMANCE REQUEST Fill in and circle choice
SCFM deg (F C)FLOW INLET TEMPERATURE
PSI (A G) deg (F C)INLET PRESSURE AREA AMBIENT TEMPERATURE
PSI (A G) (Ft M)OUTLET PRESSURE SITE ALTITUDE
___ 100
APPLICATION DESCRIPTION Attach sketch if necessary
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 I 131258 Customer Service Fax +1 2152561338 wwwametekdfscom
____
Application Engineering Basics
Warranty Statement
Warranty Statements
1 AMETEK ROTRON DR EN and HiE regenerative direct drive blowers are guaranteed for one full year from the date of installation (limited to 18 months from the date of shipment) to the original purchaser only Should blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related
2 Standard Products - AMETEK ROTRON moisture separators remote drives packaged units CP blowers Nasty GasTM models and special built (EO) products are guaranteed for one full year from the date of shipment for workmanship and material defect to the original purchaser only Should the blower fail we will evaluate the failure If failure is determined to be workmanship or material defect related we will at our option repair or replace the blower
3 Parts Policy - AMETEK ROTRON spare parts and accessories are guaranteed for three months from the date of shipment for workmanship and material defect to the original purchaser onlyIf failure is determined to be workmanship or material defect related we will at our option repair or replace the part
4 Non-Standard Products - Orders for specially-built products will be concidered as non-cancellable Any requested changed by customer after order acceptance will result in additional charges
Corrective Action - A written report will be provided indicating reason(s) for failure with suggestions for corrective action Subsequent customer failures due to abuse misuse misapplica-tion or repeat oense will not be covered AMETEK ROTRON will then notify you or your options Any failed unit that is tampered with by attempting repair or diagnosis will void the warranty unless authorized by the factory
Terms and Conditions - Our warranty covers repairs or replace-ment or regenerative blowers only and will not cover labor for installation outbound and inbound shipping costs accessories or other items not considered integral blower parts Charges may be incurred on products returned for reasons other than failures covered by their appropriate warranty Out-of-warranty product and in warranty product returned for failures deter-mined to be caused by abuse misuse or repeat oense will be subject to an evaluation charge Maximum liability will in no case exceed the value of the product purchased Damage resulting from mishandling during shipping is not covered by this warranty It is the responsibility of the purchaser to le claims with the carrier Other terms and conditions of sale are stated on the back of the order acknowledgement
Hazardous Locations Policy
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous explosive location without proper NEMA motor enclosure AMETEK ROTRON does not recognize sealed blowers as a substitue for explosion-proof motors Sealed units with standard TEFC motors should never be utilized where local state andor federal codes specify the use of explosion-proof equipment
AMETEK ROTRON has a complete line of regenerative blowers with explosion-proof motors Division 1 amp 2 Class I Group D Class II Groups F amp G requirements are met with these standard explosion-proof blowers
AMETEK ROTRON will not knowingly specify design or build any regenerative blower for installation in a hazardous corrosive environment without the proper surface treatment and sealing options
AMETEK ROTRON has a complete line of Chemical Processing and Nasty GasTM regenerative blowers with Chem-ToughTM stainless steel parts and seals
AMETEK ROTRON oers general application guidance however suitability of the particular blower selection is ultimately the responsibility of the purchaser not the manufacturer of the blower
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications The performance data on this page depicts typical performance under controlled laboratory conditions AMETEK is not responsible for blowers driven beyond factory specified speed temperature pressure flow or without proper alignment Actual performance will vary depending on the operating environment and application AMETEK products are not designed for and should not be used in medical life support applications AMETEK reserves the right to revise its products without notification The above characteristics represent standard products For product designed to meet specific applications contact AMETEK Technical amp Industrial Products Sales department
AMETEK DYNAMIC FLUID SOLUTIONS 75 North Street Saugerties NY 12477 USA +1 215-256-6601 - Europe +49 7703 930909 - Asia +86 21 5763 1258 I 14Customer Service Fax +1 2152561338 wwwametekdfscom
AMETEK Inc
AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with annualized sales of more than $25 billion AMETEK has nearly 11000 colleagues working at more than 80 manufacturing facilities and more than 60 sales and service centers in the United States and over 30 other countries around the world
AMETEK DYNAMIC FLUID SOLUTIONS (DFS)
AMETEK Technical amp Industrial Products is a world leader in motors blowers and pumps for mass-transit medical business machine and computer applications It also is a leader in regenerative blowers for pressure and vacuum applications used by broad range of industries
AMETEK supports its customers globally from its manufacturing facilities in Minnesota New York North Carolina Ohio Pennsylvania Italy and China Our brushless DC motors blowers controllers pumps and fans are ideally suited for a wide range of applications including medical instruments robotics pumps compressors offi ce equipment fans machine tools tape drives or any other precise rotary motionair delivery applications
Technical amp Industrial Productsrsquo product line of regenerative blowers for pressure and vacuum applications services the process industrial environmental waste and wastewater industrial industry Typical applications areas include solution agitation and aeration pneumatic conveying part hold-down and pick up part blow off gas and fume extraction and process gas handling
AMETEK Technical amp Industrial Products supplies the solution for unique performance mounting environmental and agency requirements
DYNAMIC FLUID SOLUTIONS
100 East Erie St Kent OH USA 44240USA +1 330-677-3327 - Europe +49 7703 930909 - Asia +86 21
5763 1258 Customer Service Fax +1 2152561338 wwwametekdfscom
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Blank Page
- Untitled
- Untitled
- Untitled
- Untitled
- Blank Page
- Blank Page
- Blank Page
- Blank Page
-