LIST OF DEDICATED APPLICATIONS
CLINICAL CHEMISTRY - IMMUNOTURBIDIMETRY - TOXICOLOGY
The SAT 450 has all parameters set based onAMS reagent kits given below.
α AMYLASE - Liquid stable Enzymatic CNPG3ALBUMIN - Liquid stable Colorimetric BCGBILIRUBIN Total - Liquid stable Colorimetric Jendrassik-GroffBILIRUBIN Direct - Liquid stable Colorimetric Jendrassik-GroffCALCIUM ARSENAZO - Liquid stable ColorimetricCALCIUM OCP - Liquid stable ColorimetricCHLORIDE - Liquid stable ColorimetricTOTAL CHOLESTEROL - Liquid stable Enzymatic colorimetricHDL DIRECT - Liquid stable Direct enzymaticLDL DIRECT - Liquid stable Direct enzymaticHOMOCYSTEINE - Liquid stable EnzymaticENZYMATIC CREATININE - Liquid stable Enzymatic colorimetricCREATININE - Liquid stable Jaffè modifiedGAMMA-GT - Liquid stable EnzymaticLDH - Liquid stable Enzymatic DGKCPHOSPHOROUS UV - Liquid stable EnzymaticGLUCOSE - Liquid stable Enzymatic colorimetricMAGNESIUM XB - Liquid stable ColorimetricTOTAL PROTEIN - Liquid stable Colorimetric (Biuret)PYROGALLOL PROTEIN - Liquid stable ColorimetricTRIGLYCERIDES - Liquid stable Enzymatic colorimetricURIC ACID - Liquid stable Enzymatic colorimetricIRON FERENE - Liquid stable ColorimetricGOT/AST - Liquid stable Enzymatic IFCC-SCEGPT/ALT - Liquid stable Enzymatic IFCC-SCEALP - Liquid stable Enzymatic DGKCUREA UV - Liquid stable EnzymaticCHOLINESTERASE - Liquid stable Enzymatic DGKCENZYMATIC HbA1c - Liquid stable Direct EnzymaticGLICOTEST HbA1 - Liquid stable Direct Latex immunoturbidimetricCK-NAC - Liquid stable Enzymatic IFCCASO Latex - Liquid stable Latex immunoturbidimetricCRP Latex - Liquid stable Latex immunoturbidimetricRF Latex - Liquid stable Latex immunoturbidimetricFERRITIN Latex - Liquid stable Latex immunoturbidimetricMICROALBUMIN Latex - Liquid stable Latex immunoturbidimetricIgA - Liquid stable ImmunoturbidimetricIgG - Liquid stable ImmunoturbidimetricC3 - Liquid stable ImmunoturbidimetricIgM - Liquid stable ImmunoturbidimetricC4 - Liquid stable ImmunoturbidimetricTRANSFERRIN - Liquid stable Immunoturbidimetric
AMPHETAMINE / METHAMPHETAMINEBARBITURATESBENZODIAZEPINESCANNABINOIDS (THC)COCAINEECSTASY (MDMA)EDDPMETHADONEOPIATESETHIL ALCOHOL
Description
SPECIFICATIONS
�� Benchtop, fully automatic, random access, open analyzerfor clinical and immunoturbidimetric assays
�� End point, Kinetic, Differential, Bichromatic,Fixed Time and Immunoturbidimetric
�� up to 999 tests, all user programmable
Up to 72 reagents can be located into the refrigeratedcompartment and distribuited on:�� 4 removable racks�� 50/20/5 ml containers can be loaded�� 8 extra positions for 5 ml containers
�� 4 universal, separate racks for continuos loading of samples,calibrators and controls
�� each rack contains up to 15 cups and/or tubes 10-16 mmdiam., 40-100 mm height
�� 8 extra positions for urgent samples, calibrators and controls�� STAT sample execution is allowed at any time
Up to 440 tests/hour including I.S.E.
�� direct reading, dual channel photometer�� 200 µl minimum reading volume�� 9 narrow band, automatically selected interferential filters
340, 380, 405, 492, 510, 546, 577, 620, 690�� halogen lamp 6V/10W�� linear from 0.0001 to 4.200 Abs.�� high resolution (0.0005 Abs.)
SYSTEM DESCRIPTION
READING SYSTEM
THROUGHPUT
SAMPLE LOADING
REAGENTS ON BOARD
ASSAY TYPES
Method Drugs of abuse
AMS SpAInstruments Factory, Sales & Customer ServiceVia E. Barsanti 17/A00012 Guidonia - Rome (Italy)Tel. +39 0774 354441Fax +39 0774 578035www.ams-analyzers.cominfo@ams-analyzers.com
Reagents Factory, Sales & Customer ServiceVia G. Galilei 3820096 Seggiano di Pioltello - Milan (Italy)Tel. +39 02 9291891Fax.+39 02 92918939www.ams-analyzers.cominfodiagnostics@ams-analyzers.com
One mechanical arm performs all sampling operations with:�� liquid level sensing (capacitive)�� reagent pre-warming at 37°C�� automatic probe washing�� sample volume range: 2.0 µl ÷ 99 µl (0.25 µl incr.)�� reagent 1 volume range: 2.0 µl ÷ 348 µl (1 µl incr.)�� reagent 2 volume range: 2.0 µl ÷ 330 µl (1 µl incr.)�� reagent 3 volume range: 2.0 µl ÷ 330 µl (1 µl incr.)�� sample pre-dilution�� sample post-dilution�� sample post-concentration
holds 80 cuvettes divided into 4 racks with 20 cuvettes eachand performs the following operations:�� automatic cuvettes washing�� continuous monitoring of cuvettes quality�� incubation temperature control at 37°C ± 0.3
(minimum requirements)�� CPU: Intel or AMD�� MEMORY: Ram 2 Gb�� HARD DISK: 250 Gb�� MONITOR: 17“�� COMMUNICATION: USB and/or RS232 port�� HOST COMMUNICATION: RS232 or Ethernet�� SOFTWARE: WINDOWS XP or higher (32 bit only)
�� Direct potentiometry I.S.E. module for Na+, K+, CI-�� Positive barcode readers for reagents and samples (code
128, codebar, code 2 of 5 interleaved, code 39)
Power Supply: 90 ÷ 250 VAC, 47 ÷ 63 HzElectric consumption: 386 WattWater Consumption: 1.5 l/h
Analytical Module:�� Width: 107 cm�� Depth: 68 cm�� Height: 50 cm�� Weight: 49 KgRoom Temperature: 18°C ÷ 30°CRelative Humidity: 20% ÷ 85%
All the above features can be changed without prior notice.
IVD
SAMPLING PROCESS
DIMENSIONS, WEIGHT & ENVIRONMENT
INSTALLATION REQUIREMENTS
OPTIONS
COMPUTER
REACTION PLATE
Zes
i Tip
og
rafi
a sr
l- T
el. +
39 0
6 45
1300
2
AMS is a Company of Group
RANDOM ACCESS ANALYZERFor Rout ine and Special Chemis t r y
S IMPL ICITY AND TECHNOLOGY
SOFTWARE OVERVIEW
The SAT 450 operating software runs under multitaskingWINDOWS XP, VISTA and 7.Its bright graphical user interface simplifies routine work andoffers the operator a concise guide through the operatingfunctions.
�� real time presentation of samples and reagents status�� dynamic monitoring of test execution�� analyzer detailed status with error messages, incubation
temperature control, START, STOP, and PAUSE functions
�� all parameters are completely user programmable�� up to 999 methods can be memorized�� all settings are user programmable�� user selectable pre-dilution and re-dilution ratio�� user selectable samples re-run option�� test calculation models are user selectable: Factor, Stan-
dard, Linear Fit, Point to Point, Quadratic, Cubic, Quartic,Cubic Inv., Log-Logit, Log-Log Cubic
�� end point limit�� substrate depletion�� fixed time and kinetic reaction linearity
�� display of test reaction curves�� display of test calibration curves�� Levy-Jennings QC statistic
�� each instrument part can be singularly tested�� remote diagnostic capability
�� multilanguage files (user programmable)�� bi-directional communication compliant with ASTM and CLSI
standard�� automatic transmission of patients data and results through
serial port or Ethernet�� reagents data traceability and management
MORE FEATURES
MONITOR SCREEN (1)
DIAGNOSTIC SOFTWARE (4)
GRAPH SCREEN (3)
AUTOMATIC DETECTION OF:
METHODOLOGY PROGRAMMING (2)
SAT 450 is a fully automatic, random access analyzer designed to support the modern laboratory in achievingimproved cost efficiency, reduced rerun and manual handling. It provides quality results while following rigid qualitysystem procedures and in strict compliance with regulatory agency requirements.
· direct measurementof Sodium, Potassium
and Chloride· easy access for
reagents replacement· maintenance-free electrodes
�� 80 long life, 6 mm optical path,semi-disposable cuvettes(4 separate racks with 20 cuvettes each)�� selective cuvettes wash with 3 different
liquids: acid, alkaline and neutral�� water low consumption: 1.5 l/h
�� 200 µl minimum reaction volume�� cuvettes quality automatic check
�� 4 universal racks for cups and primary tubes�� continuous loading of up to 15 samples on
each rack (serum, plasma, urine)�� additional 8 positions�� STAT samples loading allowed at any time�� standards and controls can be placed
on any avaible rack with no limitations�� positive identification of samples (optional)
�� up to 64 reagents on 4 separate racks�� additional 8 positions�� on board storage at 8°C ÷ 12°C�� barcode tracking of reagents (optional)�� possibility to close the system with dedicated reagents (optional)
�� advanced technology andsophisticated systemenginering allow easyaccess for maintenancepurposes by simplylifting up the entirelight-weight analytical chas-sis
I.S.E. MODULE (OPTIONAL)
COST EFFICIENCY
FLEXIBILITY
PRACTICAL DESIGN
ON BOARD REAGENTS
SIMPLICITY, PRODUCTIVITY,QUALITY RESULTS
1
2
3
4
a single, heated levelsensing arm minimizesmechanical complexityand rapidly moves to allpositions for:�� optimized sample
and reagent mixing�� up to 3 different reagents
addition to each method
�� sample pre-dilution�� sample rerun with or without dilution�� probe double washing between each sampling cycle�� inner and outer probe washing after every cycle