1 02 044025 180 600 g 25 20 mm 18 cm vacumirage
Post on 28-Nov-2021
0 Views
Preview:
TRANSCRIPT
Smart technology for Safe solutions.SmartSafe
ww
w.s
mar
tsaf
e.pi
csol
utio
n.co
m
VacuMirageSolution
Pre-assembled setwith luer adapterand holder
VacuMirageThe pre-assembled set with SmartSafe butterfly needlethat changes the face of vacuum blood sampling.
What is VacuMirage SmartSafe?It is the practical pre-assembled set by Pic Solution that consists of a Mirage SmartSafe butterfly needle, a luer adapter and a holder.It provides for vacuum blood sampling at unmatched levels of protection thanks to the SmartSafe technology.It allows fast and easy insertion in the vein while following standard procedures.It is an extremely simple safety system with direct activation in the vein to reduce contact with the needle to a minimum.VacuMirage Smartsafe is the solution for the comfort of patients and healthcare professionals that is available in two different models and with a wide range of gauges and lengths and it allows a comfortable solution for blood draws.
VacuMirage SmartSafe
Pic SmartSafeThe Pic experience brings to you the technologyto fight biological risk.
In its ongoing engagement to find cutting-edge solutions to improve the quality of its products, Pic Brand has always
stood for innovation and research. For over 50 years it has been manufacturing Pic brand medical devices for injection and
infusion therapy and for collecting samples.
Injuries due to accidental needlesticks are still a major risk for those working in hospital and healthcare settings: the
danger of over 60 pathogens can be lurking in a small drop of blood, including hepatitis B, hepatitis C and HIV1.
A constantly maximum level of protection requires great experience in safety in hospital settings, total dedication to the
development of innovative solutions and great attention to the needs of healthcare professionals: the technology of the
SmartSafe range of products is built on this body of expertise and embodies Pic’s commitment to prevent and reduce the
risk of accidental needlesticks.
· Sterile disposable luer adapter· Disposable standard holder
Separate accessories:
Pre-assembled setwith luer adapter
1080
60_M
_2
00
099
250
300
020
Descrizione prodotto Pikdare Code Diameter Needle length
Tube length
1 02 044025 180 600 G 25 20 mm 18 cm
2 02 044025 300 600 G 25 20 mm 30 cm
3 02 044023 180 600 G 23 20 mm 18 cm
4 02 044023 300 600 G 23 20 mm 30 cm
5 02 044021 180 600 G 21 20 mm 18 cm
6 02 044021 300 600 G 21 20 mm 30 cm
7 02 044025 180 700 G 25 20 mm 18 cm
8 02 044025 300 700 G 25 20 mm 30 cm
9 02 044023 180 700 G 23 20 mm 18 cm
10 02 044023 300 700 G 23 20 mm 30 cm
11 02 044021 180 700 G 21 20 mm 18 cm
12 02 044021 300 700 G 21 20 mm 30 cm
VacuMirage SmartSafe
Blood collection set with safety butterfly needle and pre-assembled holder and luer adapter.
Blood collection set with safety butterfly needle and pre-assembled luer adapter.
Descrizione prodotto Pikdare Code Diameter Needle length
Tube length
1 02 0 44025 500 510 G 25 20 mm 30 cm
2 02 044023 500 510 G 23 20 mm 30 cm
3 02 044022 500 510 G 22 20 mm 30 cm
4 02 044021 500 510 G 21 20 mm 30 cm
5 02 044019 500 510 G 19 20 mm 30 cm
Mirage SmartSafe
Safety butterfly needle
Descrizione prodotto Pikdare Code Accessories
13 02 044010 000 600 Luer adapter
14 02 044020 000 600 Holder Luer adapter
Holder
VacuMirage
PIKDARE S.p.A.Via Saldarini Catelli, 1022070 Casnate con Bernate (CO) - ITALYPhone +39 031 7297111Fax +39 031 7297100www.pikdare.com - www.picsolution.com
All rights reserved. The texts, information and other data published in this presentation are purely indicative and have the sole purpose of being used for illustration purposes by Pikdare S.p.A. and its affiliates. The reproduction, publication, dissemination and / or distribution, in any way and / or form, total and / or partial, of all the material contained in this presentation (including, by way of example only and not limited to, the texts, the images, the videos and graphic elaborations) are expressly prohibited.
It’s easy with Pic!It’s easy with Pic!It’s easy with Pic!
Bibliography:1. Gruppo di Studio PHASE “Prevenzione dell’esposizione occupazionale al rischio biologico derivante da lesione percutanea accidentale (puntura, ferita, taglio) nel settore ospedaliero e sanitario. Compendio tecnico e raccomandazioni per il recepimento e l’attuazione in Italia della Direttiva 2010/32/UE del Consiglio dell’Unione Europea”. 2012.2. Laposata M. Patient-specific narrative interpretations of complex clinical laboratory evaluations: who is competent to provide them? Clin Chem 2004; 50: 471-2.3. The Association of Clinical Biochemistry and the Royal College of Phatologists. NHS clinical biochemistry “a profession under siege”. 2002, wwww.acb.org.uk (accessed February 2013).4. Silverstein MD. An approach to medical errors and patient safety in laboratory services. A white paper. The Quality Institute Meeting, Atlanta, April 2003.5. Plebani M. et al. Note metodologiche sull’acquisizione e sull’uso dei sistemi chiusi sottovuoto per il prelievo, il trattamento e la conservazione dei campioni ematici venosi destinati alla diagnostica di laboratorio. Biochimica clinica, 2013, vol. 37, n. 46. GERES (Groupe d’Etude sur le Risque d’Exposition des Soignants) in: F.Lamontagne et al. Role of Safety-Engineered Devices in Preventing Needlestick Injuries in 32 French Hospitals. Infect Control Hosp Epidemiol 2007; 28:18-2314.7. B .L. Cullen et a l. Potential f or reported n eedlestick injuries prevention a mong h ealthcare workers t hrough s afety device u sage and i mprovement o f guideline adherence: e xpert panel assessment. Journal of Hospital Infection (2006) 63, 445-45116.8. The National Surveillance System For Healthcare Workers (NaSH) & Centers for Disease Control and Prevention (CDC). Summary Report for Blood and Body Fluid Exposure Data Collected from Participating Healthcare Facilities (June 1995 through December 2007).9. Abiteboul D, Lolom I et al. “ABEs: is protection possible? Multi-centre survey of ABEs involving General and Intensive Care Nurses” GERES, 2003.
VacuMirage SmartSafeSafety at every step of the vacuum collection procedure.
• The needle vanishes inside the safety device.
Dual-purpose circular casing.
Connection tube
Flexible, transparent and resistant to bending
and twisting to maintain a steady flow.
Available in lengths of 18 cm and 30 cm.
Holder
Support for collection compatible with the
most common tubes available on the market: it
creates a closed circuit between the patient’s vein
and the test tube preventing potential risks of
exposure.
Luer adapter
A rubber membrane covers the
needles allowing multiple draws.
Types of blood draws thatcan cause accidental needlesticks9
Grips and grooves
Their presence on the upper part of the device
favours retracting the needle.
Safe use and easy monitoring: a double signal—acoustic and visual—alerts the healthcare professional that it is activated.
In addition, the special design of the safety mechanism reduces the scattering of blood drops to a minimum.
1 2 3
”CLICK”
Early activation.
SmartSafe has a double activation mode:
· early activation, possible when extracting the needle from the vein.
This mode is also the most highly recommended because it reduces the risk of accidental needlesticks to a minimum;
· activation after extracting from the vein.
experienceTM
Triple high-penetration bevel for
comfortable insertion in the vein without
trauma.
Wings
The knurled surface provides a soft slip-proof grip. In addition,
the upper part of the device allows locking them to facilitate
insertion.
Wings and fitting
International colour coding for immediate identification of the needle gauge.
Vacuum blood collection: just as important asthe safety of the person collecting the blood.
SmartSafe Technology:double activation mode,double safety during draws.
On average, two out of every three clinical decisions are based on laboratory results.2,3,4
The diagnosis of diseases, monitoring of treatment and patient management largely depend on the results of blood tests: their precision and correct interpretation is essential for making the right choice. And the safety of the person collecting the blood is just as essential: in the diagnostic process (exam order, patient preparation, analysis of the collected samples) the pre-analysis phase is not only the one in which 45% to 70% of all errors5 is concentrated, but it is also the one in which healthcare professionals are most exposed to biological risk6, accounting for 42% of the cases in Italy of seroconversion to HIV, HBV or HCV due to accidental needlesticks.
SmartSafe
Te c h n o l o g y
Winged infusion sets
Vacuum blood collection
systems
Needles and syringes
Other devices
17%5%
14%64%
• It seals the lumen of the tube preventing the blood from flowing back after use.• It stops the needle from advancing inside the sheath.
Vacuum blood collection systems like VacuMirage SmartSafe make it possible today to demand more from blood draws:
· more safety: venous access devices with safety system cut the risk of accidental needlesticks by over 80%7,8 compared to conventional needles;
· more accuracy: the quality level of the blood specimens reduces error to a minimum.
It’s easy with Pic!