FreelanceThe easy-to-useprocess control system
ABB Process Automation, Thwe Lin Han
© ABB / PA / Control Systems© ABB GroupMay 23, 2013 | Slide 2
ABB SystemsOfferings
• System 800xA• Operator Effectiveness• Automation and Power Integration• Integrated Safety• Enterprise Asset Management
ExtendedAutomation
• Freelance DCS• A full fledge easy to use Distributed Control
System• Compact Product Suite• A comprehensive suite of best-in-class control
products
EssentialAutomation
© ABB / PA / Control Systems© ABB GroupMay 23, 2013 | Slide 3
ABB Essential AutomationOfferings
• Ease of Use• Reliable• Scalable• Value for Money
FreelanceSystem
• A comprehensive suite of best-in-class controlproducts
• Flexibility of choice• Can be used in combination or standalone
CompactProduct
Suite
© ABB / PA / Control Systems
ABB Control SystemsExtended Automation & Essential Automation
© ABB / PA / Control Systems
What is Freelance?
Control Builder F DigiVis
+ I/O’s
AC 700F AC 800F
May 23, 2013 | Slide 5
Freelance is a Distributed Control System made up of these components
Engineering Tool ControllerOperator Station Controller
© ABB / PA / Control Systems
One common SW setupfor whole DCS
§ Engineering Tool
§ Operator Interface
§ Controller Emulator
à All on one PC
What’s special about Freelance?Smallest footprint HW and SW wise
May 23, 2013 | Slide 6
§ Installation in less than 5 minutes
§ Standard Office PC can be used(could run on your notebook)
§ Just Windows, no 3rd party SWneeded
§ Train yourself with Quick StartDVD (Computer Based Training)
Software Hardware
© ABB / PA / Control Systems
FreelanceFocus on Ease of Use
May 23, 2013 | Slide 7
Easeof Use
Pre-engineered
Easyto handle
Easyto extend
Easyto learn
© ABB / PA / Control Systems
SFC DisplayEvent listSystem Display (Module Diagnostics)
Example for Pre-Engineered in Freelance
May 23, 2013 | Slide 8
Group DisplayAlarm Line & Tool BarAutomatic Context Menu with aspects viewsFaceplate (Access on Tags)Overview Display (Table of Contents)Trend Display (Data Historian) DigiVisAC 700FAC 800Fpre-engineered
Automation market
Minimum EngineeringMaximum Automation
© ABB / PA / Control Systems
FreelanceScalable Architecture
May 23, 2013 | Slide 9
AC 700FController
with direct I/O
Profibus
Modbus
Engineering:Control Builder F
Industrial Ethernet(optionally redundant)
1 PC - optional Dual Screen
Operator Station:DigiVis
Start with just 16 I/O !!
AC 700FController
Add more controllersAdd Panel 800
Panel 800
© ABB / PA / Control Systems
FreelanceScalable Architecture
May 23, 2013 | Slide 10
EngineeringStation:
Control Builder F
OperatorStations:
DigiVis
Operator Stations:Extended Operator
Workplace
AC 700FController
with direct I/O
Profibus
Modbus
Panel800
AC 700FController
Industrial Ethernet(optionally redundant)
Add moreOperatorStations
FieldDevices
UniversalMotorcontroller
Profibus
AC 800FController
FoundationFieldbus
AC 800FController,redundant
S800 I/OS800L I/O
S900I/O
Add Redundancy
© ABB / PA / Control Systems
FreelanceScalable Architecture
May 23, 2013 | Slide 11
© ABB / PA / Control Systems
Start with Freelance
§ As small as 16 I/Os + 1 OS/ES(all in one PC)
FreelanceScalable Architecture
May 23, 2013 | Slide 12
Grow easily later by adding...§ ... I/Os to existing Controller§ ... another DigiVis Operator Station§ ... another Controller§ ... Fieldbus§ ... Batch, Information Management§ ... Extended Operator Workplace
© ABB / PA / Control Systems
EngineeringControl Builder F – One tool for all
May 23, 2013 | Slide 13
§ Graphics configuration for operatorstation (DigiVis)
§ IEC 61131-3 programminglanguages
§ Graphic macro library with morethan 200 symbols
§ Function block library
§ Hardware and softwareconfiguration
§ Integrated fieldbus management
§ Online downloads andcommissioning
§ Cross-referencing of signalssystem wide
Software Hardware
© ABB / PA / Control Systems
Choose your IEC 61131-3 language
§ Function block library
§ More than 220 tested functionblocks with faceplates
§ Sequential Function Chart
§ Instruction List
§ Ladder Diagram
Control Builder FProgramming Languages
May 23, 2013 | Slide 14
§ Structured Text
§ Function Block Diagram
Why is that good?
§ Each language has it’s strengths.
§ Different editors are preferred by different users.
§ User can choose preferred language.
© ABB / PA / Control Systems
Pre-engineered visualizationcomponents§ Faceplates§ System display for hardware
diagnostics§ Extended hardware troubleshooting§ Event list, alarm line, trend displays
and automatically generatedSFC displays
Freelance Engineering ToolControl Builder F
May 23, 2013 | Slide 15
§ Configure intelligent field devicesand I/O’s
§ Fieldbus management fullyintegrated
§ Ready-made controller-to-controllercommunication
© ABB / PA / Control Systems
Fieldbus Management in Freelance
May 23, 2013 | Slide 16
§ Built-in Fieldbus support for§ PROFIBUS§ Fieldbus FOUNDATION§ HART§ MODBUS and others
§ Covers bus and deviceconfiguration
§ Setting fieldbus topology andparameters
§ E.g. transmission ratesand addresses
§ Scan bus for new devices§ Easy configuration and
diagnostics of field devices withFDT-technology
© ABB / PA / Control Systems
Device Type Manager (DTM)
§ Configuration andmanagement tool for fielddevices
§ Provide state-of-the-artgraphical user interface
§ Contains all graphical userdialogs, device configuration,diagnosis and maintenance
§ Operate on many controlsystems or asset managementtools without extra effort
Device Type Manager (DTM)Solves problem of intelligent field device engineering
May 23, 2013 | Slide 17
Fieldbus management
© ABB / PA / Control Systems
§ Open, standardized interface§ Supported by major intelligent
device vendors§ Proven by end users§ FDT enables device vendor to write
applications (DTM’s) fitting best totheir device
§ Efficient fieldbus and devicemanagement§ Similar device types (e.g.
Pressure) are presented inengineering tool with samestyle, reducing engineeringeffort
§ Free choice of device and systemsfor users
§ Consistent engineering data§ Support of full device functionality§ Plug and play
FDT/DTMBenefits and Opportunities
May 23, 2013 | Slide 18
© ABB / PA / Control SystemsMay 23, 2013 | Slide 19
§ GSD-File
What if a DTM is not available?
Slave TemplateSlave with structuredI/O and parameters
Slave BusParameter Set
§ I/O-Data description
§ Parameter description
§ User Dialogs
Fieldbus management
© ABB / PA / Control Systems
§ Easy Operation & Diagnosticsof entire system
§ Redundancy with 2 DigiVisStations
§ Offers many visualizationoptions:§ Dual monitor operation§ Free graphic displays
§ Standard graphic elements§ Bitmaps, 3D macro library
§ Clearly structuredfaceplates for operatorinterventions includinggroup displays
§ Trend displays includinghistorian
FreelanceOperator Interface: DigiVis
May 23, 2013 | Slide 20
© ABB / PA / Control Systems
Operator Interface: DigiVisMore visualization options
May 23, 2013 | Slide 21
Automatically generatedsystem displays for
§ Hardware diagnostics
§ Alarm pages for specific plantareas
§ Sequence control displays
§ Shift logs
§ Event logs
§ Excel reports
§ Data archiving
© ABB / PA / Control Systems
§ It’s a predefined display
§ It allows for diagnosticinformation about thecontroller hardware andconnected field devices
BenefitsSystem Display and Extended Diagnostics
May 23, 2013 | Slide 22
Mismatch between configuredand existing module
Some problemdown that module
© ABB / PA / Control Systems
FreelanceController – AC 800F
May 23, 2013 | Slide 23
Two versions
§ PM 802F:Typical up to 400 I/Os
§ PM 803F:Typical up to 1.000 I/Os
Redundancy for high availability
Fieldbus support
§ Profibus
§ Foundation Fieldbus
§ HART
§ Modbus Master and Slave
§ CAN for Freelance Rack I/O
§ Hot swap of Fieldbus modules
AC 800F coated (G3 compliant)hardware components available
AC 800F Controller
© ABB / PA / Control Systems
FreelanceController – AC 700F
May 23, 2013 | Slide 24
§ I/O scan time of 2ms possible§ CPU capacity for 300 I/O’s§ Temperature Range: 0...60 °C§ Monitoring of channels:
§ Short circuit & line break§ CPU PM 783F:
§ Front panel display foreasy diagnostics
§ 1 Ethernet port (10 /100Mbit)
§ 1 Profibus Master§ 1 RS-232 / 485 port -
Modbus§ 1 RS-232 port - extended
diagnostic§ AC 700F attracts PLC users to
use DCS
AC 700F Controller
© ABB / PA / Control Systems
§ Full range of signal typesincluding AI, AO, DI, DO, Temp,Pulse, Frequency, Relay
§ Inputs & Outputs mixed in onemodule!
§ Easy integration of up to 8direct I/O modules percontroller
§ Terminal units available as
§ Spring type or
§ Screw type
FreelanceS700 - Direct I/Os for AC 700F
May 23, 2013 | Slide 25
S700 – High density I/O modules
© ABB / PA / Control Systems
FreelanceProfibus Remote I/O S700
May 23, 2013 | Slide 26
§ Full range of signal typesincluding AI, AO, DI, DO, Temp,Pulse, Frequency, Relay
§ Inputs & Outputs mixed in onemodule
§ 14 different I/O modules
§ 7 Digital
§ 6 Analog
§ 1 Analog + Digital
§ DC 705F – FBP Interfacemodule is a DC module
§ 8 DI + 8 DC I/O Channels
§ Easy Configuration usingTemplates
S700 – CompactProfibus Remote I/O
© ABB / PA / Control Systems
§ Full range of signal typesincluding AI, AO, DI, DO, Temp,Pulse, Frequency, Relay
§ HART® functionality
§ 0° ... +55°C (+32°F…+131° F)ambience temperature
§ All Hardware components G3Compliant
§ Hot swap of modules
§ Redundancy also on I/Omodule level
§ Flexible configuration andinstallation
FreelanceProfibus Remote I/O S800
May 23, 2013 | Slide 27
S800 - Process I/O forGeneral Purpose
© ABB / PA / Control Systems
§ Remote I/O for mounting inATEX Zones 1 and 2applications + signals fromZone 0 / 1 / 2
§ -20° ... +70°C (-4° … +158° F)ambience temperature
§ Full range of signal typesincluding AI, AO, DI, DO, Temp,Pulse, Frequency
§ HART® functionality§ Hot swap of modules,
communication interfaces andpower supply
§ All S900 Hardwarecomponents G3 Compliant
§ Hot configuration in run, fullonline configuration capabilities
FreelanceProfibus Remote I/O S900
May 23, 2013 | Slide 28
S900 - Intrinsic Safety forhazardous environments
CB220 - Compact Box
© ABB / PA / Control Systems
Class G1: Mild§ Corrosion is NOT a factor in
determining equipmentreliability
Class G2: Moderate§ Corrosion is measurableClass G3: Harsh§ It is probable that corrosion
will occurClass GX: Severe§ Only specially designed and
packaged equipment will resist
What does coated and G3 compliant mean?Classification of environmental corrosion
May 23, 2013 | Slide 29
This doesn't happen toG3 compliant modules!
© ABB / PA / Control Systems
§ Intuitive auto router in FunctionBlock Diagram (FBD) editor
§ multiple programs simultaneouslyopen
§ Optimized for efficientEngineering, fewer clicks withauto-accept!
§ 100% compatible with formerversions
§ Even 18 years old Controllersstill supported
§ Installation in 5 minutes
The new Freelance Engineering ToolControl Builder F in version 2013
© ABB / PA / Control Systems
AC 900FAC 800FAC 700F
§ Release planned for Q2 2013 as part of Freelance 2013§ Complementing Freelance controller portfolio§ More connectivity and more power§ Attractively priced
The New Freelance Controller coming soonMore Power, more Speed, more Connectivity …
© ABB / PA / Control Systems
New Ethernet basedprotocols:IEC 60870-5-104Modbus TCP
Available forDCP 02/10Field ControllerAC 700FAC 800FAC 900F
New protocols
© ABB / PA / Control Systems
§ Simple protocol based on standard Ethernet§ Reduced installation effort by standard Ethernet networks§ Can be connected directly via internet (for remote stations,
distributed devices, web applications)§ High transfer rates up to 100Mb/s§ Can be master and slave
• Transfer rates in10baseTnetworks: up to360,000 registersper second
• Transfer rates in100baseTnetworks: up to3,600,000registers persecond
New protocols: Modbus TCP
© ABB / PA / Control Systems
§ Telecontrol protocol connects Freelance with RTUs andSubstations
§ Reduced installation effort by standard ethernet networks§ Higher transfer rates§ New functions compared to serial Telecontrol:
§ Redundancy / Time sync / Module diagnostics
New protocols: IEC 60870-5-104
© ABB / PA / Control Systems
§ F: More power than existing ControllersF: high speed 100Mb/s
§ B: Up to 1,500 I/O supported including 10 directI/O modules
§ F: Station RedundancyF: Hot plug Profibus MasterB: highest availability – no single point offailure
§ F: SD Card Support for application & firmwareupdate
§ B: no PC needed.. easy startup / easy backup /easy replacement
§ F: Modbus TCP Master/SlaveF: IEC 60870-5-104 telecontrol protocol onEthernet
§ B: more connectivity and more flexibility
§ F: G3 compliant by default for all AC 900F§ B: withstands aggressive environments
The New Freelance ControllerFeatures and benefits
§ AC 900F with direct IOs
© ABB / PA / Control Systems
AC 900FLayout and Interfaces
2 slots forcommunication
modules
4 x Ethernet10/100MB
2x seriallines
Modbus
Up to 10direct IOmodules
Power24V
Display (optional)
Switches/Buttons:ResetToggleOn/off
LEDs:PowerErrorRun/StopPrim/SecBattery
Battery (below display device)
1x Diag/Radio-Clock
© ABB / PA / Control Systems
AC 900F with direct IOs
§ Redundancy: highestavailability – no single point offailure
§ SD Card Support forapplication & firmware update
§ Display for diagnosis andmaintenance
§ more connectivity§ 2 x Profibus module with
Line redundancy§ 4x Ethernet und 2x Serial§ Modbus TCP via Ethernet§ IEC 60870-5-104
telecontrol protocol onEthernet
§ Up to 10 direct IOs§ New IO types
The new ControllerAC 900F
© ABB / PA / Control Systems
§ Up to 1.500 IO for typical Process Industry application
§ Up to 320 via direct IO (10 modules)
§ Profibus for more
IO ConnectivityNon Redundant Configuration
S800/S900S800/S900
Hart DeviceHart Device
PA DevicePA Device
DrivesDrives
S700S700Direct IO
Remote IO
© ABB / PA / Control Systems
§ Station Redundancy:§ 2 CPUs§ High-speed Red. Link§ Profibus Master module§ Direct IOs for non-red. controller
The New Freelance ControllerStation Redundancy
Red. Link (100 Mb/s)
MODBUS TCP
System Bus (100Mb/s)
S800/S900S800/S900
Hart DeviceHart Device
S700S700
PA DevicePA Device
DrivesDrives
© ABB / PA / Control Systems
SD Card Support§ Load / Save configuration without PC
§ also available for AC 700Fwith Freelance 2013
§ Backup existing configuration§ Firmware update possible§ „Restore“ via Display interface
The New Freelance ControllerDetails
Termination box/converter CableIntelligent Profibus Y-Link already built in
à no need for RLM01!
Line A
Line B
© ABB / PA / Control Systems
Name IOstypical
Perfor-mance
Ethernetports
Fieldbusslots
Intro.year
AC 700F 250 100% 1 1 2008
AC 800FPM 802F
400 200% 2 4 2000
AC 800FPM 803F
1,000 200% 2 4 2003
AC 900FStandard
1,500 300% 4 2 + serial 2013
AC 900FLight
2014
AC 900FPremium
2014
Freelance Controller FamilyMore connectivity and more power
© ABB / PA / Control Systems
Hardware comparison
Parameter AC 700F AC 800F AC 900F
CPU Redudancy - þ þ
SD card support þ - þ
Profibus Master modules 1 4 2 (with portredundancy)
CAN Bus modules - 1 -
FF HSE modules - 4 -
Modbus RTU ports 1 8 2
Modbus TCP ports 1 2 4
IEC 60870-5-101 ports 1 8 2
IEC 60870-5-104 ports 1 2 4
Direct IOs þ 8 modules - þ 10 modules
Typically IOs per controller upto
250 400/1,000 1,500
Ambience temperature 0-60 °C 0 – 60 °C 0 – 60 °C
G3 compliant - optional standard
…with Freelance 2013
© ABB / PA / Control Systems
Module Type Input Range Output RangeAX 721F 4 AI + 4 AO,
12 Bit+Sign0...10 V, -10...+10 V, 0/4...20mA, Pt100/1000, Ni1000, DI
-10...+10 V,0/4...20 mA
DI 724F 32 DI, 24 VDC
24V DC, 1-wire
DA 701F 16 DI, 8 DC, 4AI, 2 AO
0...10 V, -10...+10 V, 0/4...20mA, Pt100/1000, Ni1000, DI
-10...+10 V,0/4...20 mA
§ Three Remote IO modules now also as direct IOs withinAC 900F and AC 700F§ AX 721F§ DI 724F§ DA 701F super flexible… DI, DO, AI, AO
§ More flexibility with S700!
IO UpdateS700
© ABB / PA / Control Systems
IO UpdateS800 High Density I/O modules
§ DI818 / DO818 - 32 channel 24V§ TU818 (Screw Terminations)§ TU819 (2-25 pin D-sub)
§ DI828 - 16 channel 120V /DO828 - 16 channel Relay§ TU851 (Screw Terminations)§ TU852 and TU854 redundant
MTUs w/25 pin D-subs
Approximately 20% spacesavings in typical project
(approx. 70% digital signals)
© ABB / PA / Control Systems
§ New CI920AS and CI920AB forintrinsically safe (IS) installations
§ Higher Reliability§ Up to 15 slaves per segment
behind the Fieldbus isolatingrepeater(instead of 10)
§ No line lengths limitationsbesides PROFIBUS standard.
§ Must be used together withnew IS Profibus connectorBP914S!
§ Don‘t mix old interfaceswith new connectors &vice versa!
IO UpdateS900: New Profibus Communications interfaces
Non-hazardous areaHazardous area
BP914S
BP914S
© ABB / PA / Control Systems
AC 700F§ SD Card for Application &
Firmware update§ Profibus module with Line
redundancy§ High performance Profibus
master§ New direct IO Types§ Faster than before
AC 700F and AC 800F§ Modbus via Ethernet
(Modbus TCP/IP)§ IEC 60870-5-104 telecontrol
protocol on Ethernet
Why Upgrade to Freelance 2013Benefits for the huge installed base
AC 700F
AC 800F
© ABB / PA / Control Systems
On which version is your Freelance System?
Automation Sentinel Maintain PlusThe way to make your DCS fit for the future !
Newest VersionFormer Versions
V1 V2 V3 V4 V5 V6 V7 V8 V2013V9
© ABB / PA / Control Systems
Why to subscribe to Automation Sentinel Maintain PlusMy System is on Version 9 – What would be available?
1 2 3 4 5 6 7 8
2013§ New Controller : AC 900F§ Redundancy§ Modbus TCP§ IEC 870-5-104§ Support of SD Card for Application &
Firmware§ Display for maintenance, process value …§ New Profibus master with built-in line
redundancy§ System Bus (100 MB)§ 100% more capacity§ 100% faster§ 100% compatible§ Up to 10 direct IOs, more IO types§ 4x Ethernet on board, 2x Serial
§ New Control Builder F§ Improved auto router in FBD§ Tag/Var list Excel like with easy import/exp.§ Keep several editors open at once§ Optimized for engineering workflow
improvements – auto-accept reduces clicks!§ Fully compatible to former versions§ Project Tree with auto-hide§ Installation in 5 minutes§ WIN 7 look & feel, new icons
92013
Version
© ABB / PA / Control Systems
1. Easy to Install –Less than 5 minutes
2. Easy to Learn –Less than a week
3. Easy to Understand –Available in your language
4. Easy to Engineer –Everything using one tool
5. Easy to Backup –Entire application is just one file,fits on a small memory stick
6. Easy to Scale –Grows on a linear scale
7. Easy to Demo –Runs on any notebook
8. Easy to Sell –Customers love it and finally
9. Easy to Make Money
What Characterizes Freelance?The 9 E’s!!
May 23, 2013 | Slide 49
1 2 3
4 5 6
7 8 9
© ABB / PA / Control Systems
§ Central access to all fieldinformation
§ Field devices completely integratedinto control system engineering§ Only one tool for engineering,
commissioning and diagnostics§ Save money in
§ Engineering§ Commissioning§ Testing§ Service and maintenance
§ Assembly close to the field§ Reduction of field wiring and
space requirements§ All components match and are
optimized to work together
Why use Freelance?
May 23, 2013 | Slide 50
© ABB / PA / Control Systems
Liquefied petroleum gas (LPG) recovery+ process§ 1 x Control Builder F Engineering Station
§ 2 x DigiVis operator stations
§ 1 x redundant AC 800F controller
§ 1 x S800 remote I/O station, ca. 200 I/Osignals
§ Linking Device 800HSE, ca. 70 I/Osignals Foundation Fieldbus
Oil & Gas applications
June 4, 2012 | Slide 51
Styrene production§ 1 x Control Builder F Engineering Station
§ 6 x DigiVis operator stations
§ 2 x redundant AC 800F controllers
§ 22 x S800 remote I/O stations, ca. 3,000I/O signals
© ABB / PA / Control Systems
Plastics Production (Monomer)§ 2 x DigiVis operator stations
§ 1 x redundant AC 800F controller
§ S800 remote I/O stations, ca. 400 I/Osignals
§ S900 remote I/O stations, ca. 100 I/Ointrinsic safe signals
§ 800xA Batch management
Chemical applications
June 4, 2012 | Slide 52
Coal (High Sulphur) to Methanolproduction§ 4 x Control Builder F Engineering stations
§ 16 x DigiVis dual screen operator stations
§ 18 x AC 800F controllers
§ S800 remote I/O stations, ca. 6,000 I/Osignals
§ Integrated production schedule system
§ Integrated digital video monitor system
© ABB / PA / Control Systems
Pelletizing plant to process andexport iron§ 2 x Control Builder F Engineering
workstations§ 4 x Process Portal operator
workplaces§ 14 x redundant AC 800F controllers§ S800 I/O remote I/O stations, ca.
10,000 I/O signals
Mineral applications
| Slide 53
Cement Factory§ 3 x DigiVis operator stations§ 2 x AC 800F controllers§ S800 remote I/O station, ca. 1,000
I/O signals
June 4, 2012
© ABB / PA / Control Systems
Sugar Refinery
§ 1 x Control Builder F engineeringstation
§ 12 x DigiVis Operator Station
§ 5 x AC 800F controllers
§ 4,400 Rack I/O signals
Consumer applications
| Slide 54
Animal food production fromSugar Canes
§ 2 x 2 DigiVis operator station
§ 1 x AC 800F controller
§ S800 remote I/O stations, 700 I/Osignals
§ 800xA Batch management
June 4, 2012
© ABB / PA / Control Systems
Steel production
§ 1 x Control Builder F engineeringstation
§ 6 x DigiVis operator stations
§ 2 x redundant AC 800F controllers
§ 3 x single AC 800F controllers
§ 2,000 I/O Rack I/O’s
Other applications
| Slide 55
Bio Diesel Plant
§ 1 x Control Builder F engineeringstation
§ 3 x DigiVis operator stations
§ 2 x redundant AC 800F controllers
§ S800 remote I/O station, 1,500 I/O’s
June 4, 2012
© ABB / PA / Control Systems
Slab furnace§ 1 x Control Builder F engineering
station§ 15 x DigiVis operator stations§ 6 x AC 800F controllers§ S900 remote I/O stations,
ca. 2,000 I/O’s
Other applications
| Slide 56
Container Glass Production§ 1 x Control Builder F engineering
station§ 6 x DigiVis operator stations§ 11 x redundant AC 800F controllers§ S900 remote I/O stations,
ca. 4,200 I/O’s
June 4, 2012
© ABB / PA / Control Systems| Slide 57
Renewable Energy Power Plant
§ 1 x Control Builder F engineeringstation
§ 6 x DigiVis operator stations
§ 5 x redundant AC 800F controllers
§ S800 remote I/O stations, ca. 3,000I/O signals
Other applications
Waste Water Treatment
§ 1 x Control Builder F engineeringstation
§ 3 x DigiVis operator stations
§ 3 x redundant AC 800F controllers
§ S800 remote I/O stations, ca. 900I/O signals
June 4, 2012
© ABB / PA / Control Systems
Questions
June 4, 2012 | Slide 58
top related