about the iso 8573 1 standard update tcm1340-3536498
Post on 04-Jun-2018
237 Views
Preview:
TRANSCRIPT
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
1/14
About the ISO 8573-1 standard
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
2/14
2
History of ISO 8573
The original version of 1991 (edition1) standard defined 5 classes onoil concentration
The best Class 1, specifying an
oil concentration of 0,01 mg/m3
at 1 bar(a) 14.5 psia and 20oC
(68F)
Conformance to Class 1 was
sometimes called a technically
oil-free solution
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
3/14
3
ISO 8573-1 (1991)
Unusually, the standard recommended methods to remove oil from the compressedair.
Quote Oil may be removed by high efficiency filters
It also cautioned users about using oil-free compressors
Quote The quality of air delivered by non-lubricated compressors is influenced by the quality of the
intake air and the compressor design
Oil vapors, which are not removed by coalescing filters were accorded negligibleimportance (when in fact quantity of vapors may be higher than aerosols)
Quote Therefore below approximately 35 oC (95 oF), the oil vapor content may be disregarded
In effect, the provisions in the standard were not adequate to assure the purity levelsdemanded by the industry and a new edition of the standard evolved: edition 2.
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
4/14
4
Forms of oil in pipelines
When oil is present in pipelines, itis always in these three forms:
Aerosols are partially removed bycoalescing filters and appear ascondensate
Wall flow either appears in
condensate or travels to the process
Vapors are not removed by
coalescing filters!
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
5/14
5
ISO 8573-1 (2001)
Major changes: The standard now spoke about total oil content (aerosol, liquid and vapour)
A standard was introduced on measurement of oil vapour ISO 8573 part 5
A new class (Class 0) was introduced to cover more stringent quality requirements
The clause which recommended ways to remove oil was deleted
Representative samples were asked
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
6/14
6
ISO 8573-1 Testing Methods
ISO 8573-1 Part 2 Measurement of Aerosols
ISO 8573-1 Part 5 Measurement of oil fumes and vapors
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
7/14
7
ISO 8573-1 Part 2 - Aerosols
Method B1
Measurement of full flow with
membranes. Measures all aerosols and wall
flow
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
8/14
8
ISO 8573-1 Part 2 - Aerosols
Method B2
Sampling probe at the center of the
pipe is used. Wall flow is not measured
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
9/14
9
ISO 8573-1 Part 5 - Vapors
Chemical absorption of oil by useof activated carbon.
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
10/14
10
ISO 8573-1 Temperature factor
Reference Conditions: The reference conditions are
specified as 20o
C (68o
F) and 1 bar(a) (14,5 psia).
The above conditions are notrepresentative. Filters receive airat 4-10 oC (7-18 oF) above coolingmedium temperature which could
reach 30 oC (86 oF)! Also, theworking conditions of thecompressor are at higherpressures.
Oil carry over will be greater athigher temperatures !
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
11/14
11
Atlas Copcos test
TV tested Atlas Copcos Z series of oil-free rotary screw compressors at: Three different temperatures: 20 oC, 40 oC and 50 oC at the measurement point
2 different pressures: 1 bar(a) and 8 bar(a)
Why is this important? Temperatures: oil carry-over increases exponentially with increasing temperatures.
Especially at 8 bar(a), the oil concentration goes up as compared to 1 bar(a)
As production environments change from place to place, country to country
and application to application, it is important to test at all possible conditions.
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
12/14
12
ISO 8573-1 Filter factor
Another factor influencing test results when measuring oil residue incompressed air:
using lubricated compressors in combination with filters
The saturation level of the filter may affect oil carry-over.
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
13/14
Committed to
sustainable productivity.
31
-
8/13/2019 About the ISO 8573 1 Standard Update Tcm1340-3536498
14/14
14