AC INVERTER MULTI SPLIT
TYPE AIR CONDITIONER
Model: IM-MSV-0903-ACSON
INVERTER
INSTALLATION MANUAL
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 2/28
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 3/28
FORPIPEHOLEPOSITION
INTHEWALL
HOLEO65.0mmFORPIPEHOLEPOSITIONINTHEWALL
HOLE O65.0mm
CENTERLINE
OUTLINE AND DIMENSIONS
Indoor Unit (WMX-F)
i
Indoor Unit (WMX-G)
INSTALLATION
PLATE
All dimensions are in mm/ (in)
All dimensions are in mm/ (in)
FRONT VIEW
TOP VIEW
SIDE VIEW
A
B
C
FRONT VIEW
TOP VIEW
A
B
C
SIDE VIEW
Dimension
10 / 15 F / FR
20 F / FR
I
32
(1,3)
48
(1,9)
H
12
(0,5)
8
(0,3)
G
47
(1,9)
51
(2,0)
F
47
(1,9)
99
(3,9)
E
278
(10,9)
294
(11,6)
D
719
(28,3)
912
(35,9)
C
181
(7,1)
200
(7,9)
B
291
(11,4)
310
(12,2)
A
815
(32,1)
1060
(41,7)
O
172
(6,8)
160
(6,3)
N
118
(4,6)
138
(5,4)
M
100
(3,9)
160
(6,3)
L
342
(13,5)
403
(15,9)
K
302
(11,9)
354
(13,9)
J
35
(1,4)
43
(1,7)
Dimension
10 / 15 G / GR
I
56
(2,2)
H
8
(0,3)
G
124
(4,9)
F
185
(7,3)
E
246
(9,7)
D
590
(23,2)
C
198
(7,8)
B
260
(10,2)
A
899
(35,4)
O
132
(5,2)
N
128
(5,1)
M
50
(2,0)
L
495
(19,5)
K
419
(16,5)
J
50
(2,0)
E
D H
G F
K
L
MJ
I I
O
N
A
D
K
L
J M
G F
B
O
N
I I
E
H
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 4/28
Indoor Unit (WMX-G)
All dimensions are in mm/ (in)
FRONT VIEW
TOP VIEW
SIDE VIEW
INSTALLATION
PLATE
A
B
C
A
B
D FG
M
H
I I
O
N
M
K
L
J
Dimension
20 G / GR
I
48
(1,9)
H
8
(0,3)
G
51
(2,0)
F
99
(3,9)
E
294
(11,6)
D
912
(35,9)
C
220
(8,6)
B
310
(12,2)
A
1060
(41,7)
O
160
(6,3)
N
138
(5,4)
M
160
(6,3)
L
403
(15,9)
K
354
(13,9)
J
43
(1,7)
ii
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 5/28
Outdoor Unit (MSV25A)
iii
Dimension
MSV25A
A
925
(36,4)
B
839
(33,0)
C
408
(16,0)
D
378
(14,8)
E
15
(0,6)
F
38
(1,5)
G
39
(1,5)
H
590
(23,2)
I
125
(4,9)
J
356
(14,0)
K
296
(11,6)
L
318
(12,5)
W
42
(1,6)
V
216
(8,5)
U
47
(1,8)
T
141
(5,5)
S
428
(16,8)
R
87
(3,4)
Q
160
(6,3)
P
83
(3,2)
O
330
(13,0)
N
630
(24,8)
M
647
(25,4)
All dimensions are in mm/ (in)A
F B
HI I
E
D C
E G
KJ
L
O
QP R
M N S
T
U V
W W W W W W W
Dimension
MSV35A
I
390
(15,3)
H
26
(1,0)
G
44
(1,7)
F
488
(19,2)
E
20
(0,8)
D
448
(17,6)
C
141
(5,5)
B
746
(29,4)
A
1028
(40,4)
O
55
(2,2)
N
107
(4,2)
M
311
(12,2)
L
399
(15,7)
K
852
(33,5)
J
408
(16,0)
Outdoor Unit (MSV35A)
All dimensions are in mm/ (in)A
G
BC C
E
D
E G
F
I L
K
J
H N
M
O O O O O O O
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 6/28
iv
Sharp edges and coil surfaces are potential locations which may cause injury
hazards. Avoid from being in contact with these places.! Caution
This product is subjected to Waste of Electrical and Electronic Equipment Regulations (WEEE
Regulations). The waste product shall be separately collected by specific collection and treatment centre.Please refer to local authorithy for these centres. This is only applicable to European Union countries.
Ce produit est soumis à la r é lectriques eté é é é
é é é ître ces centres. Ceciest uniquement applicable aux pays de l'Union Europ enne.
Questo prodotto è soggetto alle disposizioni RAEE (Rifiuti di apparecchiature elettriche ed elettroniche).à
à locali. Questa disposizione è valida solamente i paesidell’U.E.
éctrico y Electr nico en materia deñ á ífico
de colecciósolamente aplicable a los países de la Uni n Europea.
Dieses Produkt unterliegt den Bestimmungen zur Entsorgung von elektrischen und elektronischenGerä ätes
üll bei Ihrer ö ü öändiges Abfall-Amt. Dieser
Hinweis gilt nur f r L äischen Union.
Процесс тилизации данного продукта регулируется правилами по утилизации
отходов и (WEEE Regulations).и
, . Этиправила Европейского
NOTICE
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 7/28
E n g
l i s h
Part No.: A08019020770
INSTALLATION MANUAL
INVERTER MULTI SPLIT TYPE AIR CONDITIONER
This manual provides the procedures of installation to ensure a safe and good standard of operation for the airconditioner unit.Special adjustment may be necessary to suit local requirements.
Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
IM-MSV-0903 (1)-Acson
MODEL
OUTDOOR UNIT
MSV25A / AMSV025A
MSV35A / AMSV035A
INDOOR UNIT
WMX10F / AWMX010F
WMX15F / AWMX015F
WMX20F / AWMX020F
WMX10G / AWMX010G
WMX15G / AWMX015G
WMX20G / AWMX020G
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 8/281-1
! CAUTION
Please take note of the following important points when installing.
• Do not install the unit where leakage of flammable gas may occur.
If gas leaks and accumulates at the surrounding of the unit, it may cause fire ignition.
• Ensure that the drainage piping is connected properly.
If the drainage piping is not connected properly, it may cause water leakage which will dampen thefurniture.
• Do not overcharge the unit.
This unit is factory pre-charged. Overcharge will cause over-current or damage to the compressor.
• Ensure that the units panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
CONTENTS
- Outline and Dimensions page i-iv- Safety Precautions page 1- Installation Diagram page 2- Installation of Outdoor Unit page 3- Installation of the Indoor Unit page 4- Refrigerant Piping page 5- Electrical Wiring Connection page 7- Ampere Limit Change Method page 8
- Vacuuming and Charging page 10- Indicator Lights page 11- Air Conditioner Unit Operation page 13- Operating Range page 13- Electrostatic filter page 14- Auto Random Re-start Function page 14- Service and Maintenance page 15- Troubleshooting page 16
Before installing the air conditioner unit, please read the following safety precautions carefully.
SAFETY PRECAUTIONS
! WARNING
• Installation and maintenance should be performed by qualified persons who are familiar with local code and
regulation, and experienced with this type of appliance.
• All field wiring must be installed in accordance with the national wiring regulation.
• Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring workaccording to the wiring diagram.
• The unit must be GROUNDED to prevent possible hazards due to insulation failure.
• All electrical wiring must not touch the refrigerant piping, compressor or any moving parts of the fan motors.
• Confirm that the unit has been switched OFF before installing or servicing the unit.
• Before servicing inverter air conditioning unit, switch off the power and wait for 2 - 3 minutes for controller todischarge.
IMPORTANT
DO NOT INSTALL OR USE THE AIR CONDITIONER UNIT IN A LAUNDRY ROOM.
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 9/281-2
E n g
l i s h
INSTALLATION DIAGRAM
Indoor Unit Air Filter
Outdoor Unit
Front Frame
Back Housing
ON/OFF SwitchAir Intake
Grille
Indicator Light
Signal Receiver
DrainHouse
OUTDOOR UNIT
INDOOR UNIT
Indoor Unit Combination
Indoor Units with model name WMX10F, WMX15F, WMX20F, WMX10G, WMX15G and WMX20G could be coupled withthis outdoor unit. The following table shows the possible coupling combinations available.
However, there are a total of 21 operation combinations available with this outdoor unit, from one unit to four units. For further details on operation combinations, total capacity and other technical specifications, please refer to the technical manual.
No. Coupling Combinations (WMX)
1 10 + 10 + 10 + 10
2 10 + 10 + 10 + 15
3 10 + 10 + 10 + 20
4 10 + 10 + 15 + 15
5 10 + 10 + 15 + 20
6 10 + 15 + 15 + 15
7 15 + 15 + 15 + 15
Return Air
Air Discharge Nozzle
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 10/281-3
The outdoor unit must be installed in such a way, so as to prevent short circuit of the hot discharged air or obstruction to thesmooth air flow. Please follow the installation clearance shown in the figures on the right. Select the coolest possible placewhere intake air temperature is not greater than the outside air temperature (maximum 45°C/113°F). Ensure that the unit isinstalled 1 or 2 meter away from other electronic devices like television or radio to prevent interference.
Note: If there is any obstacle higher than 2m (6.56ft), or if there is any obstruction at the upper part of the unit, please allow
more space than the figure indicated in the table shown below.
Before installing the piping and connecting rod, please remove the access panel and plastic valve plate cover or service panelfor easy access and safety. Refer to figures shown below.
INSTALLATION OF OUTDOOR UNIT
PLEASEREMOVE
SERVICE
PANEL
PLEASE
REMOVE
ACCESS PANEL
& PLASTICVALVE COVER
PLATE WHEN
CONNECTING
THE PIPING
ANDCONNECTING
CORD.
PUSH & PULL UP
Dimension AMinimum 300 1000Distance (mm) (11.8) (39.4)
Installation Clearance
B C D300
(11.8)500
(19.7)
C D
A B
SERVICESPAC
E
RETURNAIR
OBSTACLE
AIR
DISCHARGE
OBSTACLE
RETURNAIR
OBSTACLE
OBSTACLE
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 11/281-4
E n g
l i s h
Hole With Cone Drill
Indoor Side Outdoor Side
INSTALLATION OF THE INDOOR UNIT
Mounting Installation PlateEnsure that the wall is strong enough to withstand the weightof the unit. Otherwise, it is necessary to reinforce the wallwith plates, beams or pillars.Use the level gauge for horizontal mounting, and fix it with4 suitable screws.In case the rear piping draws out, drill a hole 65mm in diam-
eter with a cone drill, slightly lower on the outside wall (seefigure).
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of theinstallation plate (Engage the two hooks at the rear top of the indoor unit with the upper edge of the installation plate).Ensure that the hooks are properly seated on theinstallation plate by moving it to the left and right.
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for smooth drainage. Avoid situations that are likely to causewater to leak.
EndDipped
IntoWater
Water
Leaking
Water
Leaking
Water
Leaking
The indoor unit must be installed in such a way so as toprevent short circuit of the cool discharged air with the hotreturn air. Please follow the installation clearance shown inthe figure. Do not place the indoor unit where there could bedirect sunlight shining on it. Also, this location must besuitable for piping and drainage, and be away from doors or windows.
Routing Of Piping
Remove the screw holding the front panel.
The refrigerant piping can be routed to the unit in anumber of ways (left or right from the back of the unit), byusing the cut-out holes on the casing of the unit (see figure).Bend the pipes carefully to the required position in order toaligned it with the holes. For the right hand and rear sideout, hold the bottom of the piping and then position it to therequired direction (see figure). The condensation drain hosecan be taped to the pipes.
Wrong Wrong WrongCorrect
Drain
Water Drainage
1
2 3
4
5
Piping Routing
Right & Rear Side Routing
Screw position in the wall
Ø 65.0 mm Hole in the wall
Maintenance &Servicing Space
Air FlowDirection
HigherThan
EyeLevel
50.0 mm
Drain hose
Fix with vinyl tape
Unit piping
1. Hook the unit onto the installation plate.
50.0 mm
Screw position in the wall
7 2
. 0
Centre Line
Ø 65.0 mm Hole in the wall
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 12/281-5
REFRIGERANT PIPING
Piping Length & ElevationIf the pipe is too long, both capacity and reliability of the unit will drop. As the number of bends increases, resistance to theflow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective.Always choose the shortest path and follow the recommendations as tabulated below.
Individual indoor unit can have a maximum length of 12m (39.4ft) to 15m (49.2ft), maximum elevation of 5m (16.4ft) to 8m(26.3ft) and maximum number of bends of 10, however, total pipe length must not exceed 60 m (196.8ft).
Remark: The refrigerant pre-charged in the outdoor unit is for piping length up to 60 m (196.8ft).
Coupling Model WMX10 WMX15 WMX20
Max. Length, L (m / ft) 12 / 39.4 12 / 39.4 15 / 49.2L
1 + L
2 + L
3 + L
4 (Total 60 m / 196.8 ft maximum)
Max. Elevation, H (m / ft) 5 / 16.4 5 / 16.4 8 / 26.2
Max. Number of Bends 10 10 10
Liquid Pipe Size 1/4" 1/4" 1/4"
Gas Pipe Size 3/8" 1/2" 5/8"
L4
L3
L2
L1
OUTDOOR UNIT
INDOOR UNIT
VERTICALHEIGHTDIFFERENCEMAX. H
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 13/28
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 14/281-7
ELECTRICAL WIRING CONNECTION
Cooling Unit
IMPORTANT : The figures shown in the table are for information purpose only. They should be checked and selected tocomply with the local/national codes of regulations. This is also to the type of installation and conductorsused.
INDOOR UNIT D
TERMINAL BLOCK
INDOOR UNIT C
TERMINAL BLOCK
INDOOR UNIT BTERMINAL BLOCK
INDOOR UNIT A
TERMINAL BLOCK
1
2
3
N
L
1
2
3
N
L
1
2
3
N
L
1
2
3N
L
N
L
3
N
L
3
N
L
3
N
L
3
N
L
D
C
B
A
P O W E R
S U P P L Y
• All wires must be firmly connected.• All wires must not touch the refrigerant piping, compres-
sor or any moving parts of the fan motor.• The connecting wires between the indoor unit and the
outdoor unit must be clamped on the wire clamps and
the cable tie (push releasable) at the indoor unit and out-door unit respectively as shown in the figures.
• The power supply cord must be equivalent to H05RN-F(245IEC57) which is the minimum requirement.
MAIN CONTROL BOARD EARTH WIRE
FAN EARTH WIRE
POWER SUPPLYCABLE
CABLE TIE
(PUSH RELEASABLE)INTERCONNECTION
CABLE
There must be a double pole switch with a
minimum 3 mm contact gap and fuse/
circuit breaker as recommended in thefixed installation circuit.
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 15/281-8
E n g
l i s h
Model WMX10/15 WMX20
Voltage range 220-240V/1Ph/50Hz +!
Power supply cable size* mm2 3.0 4.0
Number of wires 3 3
Recommended time delay fuse for O/D unit 30
Indoor coupling models WMX10/15/20G
Interconnection cable size mm2 1.5
Number of wires 4
AMPERE LIMIT CHANGE METHOD
WARNING !
Do not attemp to adjust the “Current Limit Switch” yourself. If there is a need to meet HDB requirement or local authorities,
kindly contact our local authorized dealers.
Wire Clamp
Interconnection
Cable
Power Supply
Cable
• The table above shows the electrical wire sizing for different connection cables. If the length of the cable is more than 2m(6.65ft), use cable with bigger size.
• The figures shown in the table are for information purpose only. They should be checked and selected to comply with thelocal/national codes of regulations. This is also to the type of installation and conductors used.
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 16/281-9
Current Limit Switch Setting
• The current limit requirement set by certain countries can be activated by the “Current Limit Switch”, placed at theoutdoor unit p.c.board, as shown on the illustration.
• Before adjusting the “Current Limit Switch”, be sure to turn off the main power supply. Wait until the LED light on thep.c.board is turned off then only is safe to adjust the switch.
• The current limit settings on the switch are shown on the table below.
Current limit Switch Position
Current Limit
MSV25A MSV35A
No change11 A
(Default Setting)
8.5 A
17 A
23 A(Default Setting)
11 A
17 A
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 17/281-10
E n g
l i s h
➝
VACUUMING AND CHARGING
Purging the piping and the indoor unitExcept for the outdoor unit which is pre-charged withrefrigerant R22, the indoor unit and the refrigerant connectionpipes must be air-purged because the air containing moisturethat remains in the refrigerant cycle may cause malfunctionof the compressor.
Service Port Outdoor Unit3 Ways Valve
Flare UnitRefrigerant Piping
Charge operation
This operation must be done by using a cylinder and a pre-cise weighing machine. The addit ional charge is topped-up into the outdoor unit using the suction valve via the ser-vice port.
• Remove the service port cap.• Connect the low pressure side of the charging gauge to
the suction service port center of the cylinder tank andclose the high pressure side of the gauge. Purge the air from the service hose.
• Start the air conditioner unit.• Open the cylinder and low pressure charging valve.• When the required refrigerant quantity is pumped into
the unit, close the low pressure side and the cylinder valve.
• Disconnect the service hose from service port. Put backthe service port cap.
Allen Key
Open
Open
SuctionValve
DischargeValve
Indoor Unit Outdoor UnitLiquid side
Gas side
CheckValve
Close
Hi
Low
SuctionValve
DischargeValve
Indoor Unit Outdoor UnitLiquid side
Gas side
Vacuum
pump
Open
Close
Close
Close
HiLow
Make sure all pipes are connected securely to the outdoor and indoor valves.
Remove the caps from the flare valves and the service ports(or ball valves). Take note that there are a total of four service ports for MSV25A and two service ports for MSV35A.
➝
Connect the centre of the charging gauge to the vacuumpump.
➝
Starting from the bottom 3-way valve (labeled A),connect the charging gaugeto the 3-way valve’s serviceport. (There are a total of four 3-way valves).
➝ ➝
Connect the charging gaugeto the suction (gas side) ballvalve’s service port.
Start the vacuum pump. Evacuate for approximately 30minutes. The evacuation time varies with different vacuumpump capacity. Confirm that the charging gauge needle has
moved towards -760mmHg.
➝
Proceed to the next 3-wayvalve and repeat the stepabove for the rest of the3-way valves.
➝
(MSV25A) (MSV35A)
CautionIf the gauge needle does not move towards -760mmHg,be sure to check for gas leaks (using the refrigerantdetector) at flare type connection of the indoor andoutdoor unit and repair the leak before proceeding tothe next step.
Close the valve of the charging gauge and stop the vacuumpump.
Open the suction valve (3-way) and liquid valve (2-way) in anti-clockwisedirection with 4mm key for
hexagon sacked screw.
➝ ➝
Open the suction and liquidball valves in anti-clockwisedirection with pliers.
➝
Additional chargeThe refrigerant is pre-charged in the outdoor unit for maximum piping length. Therefore, no additional charge is required for additional piping length.
➝ ➝
➝
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 18/281-11
INDICATOR LIGHTS
IR signal receiver
When an infrared remote control operating signal has been transmitted, the signal receiver on the indoor unit will makea <beep> sound to confirm acceptance of the signal transmission. The table shows the LED indicator lights for theindoor air conditioner unit under normal operation and fault conditions. The LED indicator lights are located at thebottom right side of the air conditioner unit for WMX-F series and at the middle of the air conditioner unit for WMX-
G series.
LED Indicator Lights : Normal Operation And Fault Conditions For Cooling Unit
Action
–
–
–
Call your dealer
Call your dealer
Call your dealer
Call your dealer
Call your dealer
Call your dealer
Call your dealer
Call your dealer
Operation / Fault Indication
Timer on.
Sleep mode on.
Dry mode.
Compressor overload protection.
Indoor temperature sensors contact loose / short.
Outdoor temperature & current sensors contact loose / short.
Gas leak / compressor overheat.
Communication error between indoor and outdoor.
Inverter error / PFC error.
Outdoor total current trip / DC peak.
Indoor fan feedback error.
LED Indicator Lights
Dry mode
Power ONTimer
LED Indicator Lights for Cooling Unit
BlinkingON or OFFON
Sleep mode
Inverter Cooling Unit (WMX-F)
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 19/281-12
E n g
l i s h
Inverter Cooling Unit (WMX-G) LED Indicator Lights for Cooling / Heat Pump Unit
Sleep Mode
LED Indicator Lights : Normal Operationg and Fault Conditions for Cooling / Heat Pump Unit
LED indicator lights
IR Receiver
Cool Timer Ionizer
Normal Operation / Fault Indication Action
Cool mode –
Sleep mode on –
Timer on –
Ionizer on –
Defrost operation –
Indoor temperature sensor loose / short Call your dealer
Coil temperature sensor loose / short Call your dealer
Outdoor temperature sensor loose / short Call your dealer
Compressor overload protection Call your dealer
IPM / PFC error Call your dealer
Outdoor total current trip / DC peak Call your dealer
Compressor overheat / Gas leak Call your dealer
Indoor fan feedback error Call your dealer
Communication error between indoor
and outdoor Call your dealer
Green
ON ON or OFF Blinking
SleepMode
Cool Timer Ionizer
Green/ Red
Green/ Red
Green/ Red
Red
Red
Green
Yellow
Green
Green
Green
Green
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 20/281-13
AIR CONDITIONER UNIT OPERATION
Dry mode
• When the air humidity is high, the unit can operate in drymode. Press <MODE> button and choose <DRY>.
• If the room temperature is 2°C/35.6°F higher than the settemperature, the air conditioner will operate under coolingmode until it reaches within the 2°C/35.6°F range of
difference compared to the set temperature before itconverts to dry mode.
• If the room temperature is within the 2°C/35.6°F range of difference compared to the set temperature, it willdirectly operate under dry mode.
• The indoor fan will operate at super low speed under drymode.
Horizontal Air Flow Control
• For more effective air circulation, you can manually ad- just the air discharge grille to the left or right.
• During cool mode operation and dry mode operation, donot direct the air discharge louver downwards for too long.If operating continues in this way, condensation may oc-cur on the louver, thus resulting in drippings.
Frost prevention
• When the air filter is dirty, the evaporating temperaturewill decrease and eventually cause frosting.
• When this happens, the compressor will reduce its runningspeed to prevent freezing. If the coil temperature is stillvery low, the compressor will stop.
Fan speed and rated cooling capacity
• The rated cooling capacity is provided at the maximumfan speed.
• The cooling capacity is lower when the unit is operating atMEDIUM and LOW fan speed.
Turbo function
• If higher cooling or heating is required during operation,press "Turbo" button on the remote control to increase thecooling or heating capacity to maximum.
• This function will operate for 15 minutes before it resumeto the actual setting.
• The fan noise may be higher if the unit operates in "Turbo"mode.
OPERATING RANGE
Cooling Unit
Temperature Ts °C / °F Th °C / °F
Minimum indoor temperature 19.0 / 66.2 14.0 / 57.2
Maximum indoor temperature 32.0 / 89.6 23.0 / 73.4
Minimum outdoor temperature 19.4 / 66.92 -
Maximum outdoor temperature 46.0 / 114.8 -
Ts: Dry bulb temperature.Th: Wet bulb temperature.
Horizontal
C o o
l i n g
D r y
25˚C / 77˚F
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 21/281-14
E n g
l i s h
! WARNING
• Disconnect from the main power supply before servicing the air conditioner unit.
• DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which may resultin fire hazards.
! CAUTION
Before turning off the power supply, set the remote controller's ON/OFF switch to the "OFF" position to prevent thenuisance tripping of the unit.If this is not done, the unit's fans will start turning automatically when power resumes, posing a hazard to servicepersonnel or the user.
If there is a power cut when the unit is operating, it will automatically resume the same operating mode when the power is restored.
AUTO RANDOM RE-START FUNCTION
! CAUTION
1. The electrostatic air purifying and deodorizing filter should be replaced once every 6 months or when thefilter changes color to brownish, whichever is sooner.
2. Used dusty filters should be disposed and shouldn't bereused, even if it has been cleaned and washed.
3. The filter is a consumable part which you can purchasefrom your air conditioner dealer.
4. Use the new filter immediately once it has been takenout from its sealed packing. Do not unpack the newfilter too early before it is actually used as this maydecrease its deodorizing effect.
ELECTROSTATIC FILTER
DUAL ACTION ELECTROSTATIC AIR PURIFYINGAND DEODORIZING FILTER MEDIA AND FILTER FRAME
ACTION 1-ELECTROSTATIC AIR PURIFYING FILTER
Removes microscopic dust, smoke and small invisible
particles to keep the room air clean with pre-chargedelectrostatic polypropylene filter.
ACTION 2-DEODORIZING FILTER
Removes unwanted smells and odors in the air and keeps
the room air fresh with activated carbon filter.
HOW TO INSTALL
Open thefront frame
grille.
Slide out the originalfilters.
Slide back the originalfilter.
Insert the dual actionelectrostatic anddeodorizing filtersinto the slot.
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 22/281-15
WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME
Operate the unit for 2 hourswith the following setting.
Operating mode : coolTemperature : 30°C
Remove the power plug.If you are using an independentelectric circuit for your unit,
cut off the circuit.Remove the batteries in theremote control.
SERVICE AND MAINTENANCE
! CAUTION
Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to meltor deform as a result of the excessive heat.
Maintenance Procedures
1. Remove any dust adhering to the filter by using a vacuum cleaner or wash in lukewarm water (below 40°C) with a neutral cleaning detergent.
2. Rinse the filter well and dry before placing it back onto the unit.
3. Do not use gasoline, volatile substances or chemicals to clean the filter.
1. Clean any dirt or dust on the grille or panel by wiping it off with a softcloth soaked in lukewarm water (below 40°C) and a neutraldetergent solution.
2. Do not use gasoline, volatile substances or chemicals to clean theindoor unit.
Period
At least onceevery 2 weeks.
More frequently if
necessary.
At least onceevery 2 weeks.
More frequently if necessary.
Service Parts
Indoor air filter
Indoor unit
1 Off the unit.
2 Unscrew the air discharge housing.
3 Flip open the air discharge housing.
4 Clean the blower.
5 Close the air discharge housing and tighten it with screw.
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 23/281-16
E n g
l i s h
If there is any malfunction of the air conditioner unit detected, please switch off the main power supply immediatelybefore proceeding with the following troubleshooting procedures as safety precautions.
The followings are some common fault conditions and simple troubleshooting tips. If encounter any faulty conditions whichare not listed, please contact your nearest local dealer or service maintenance. Do not attemp to troubleshoot the unit yourself.
TROUBLESHOOTING
Possible Causes / Corrective Actions
• The air conditioner unit has a 3 minutes restart protection.Please wait for the unit to restart by leaving the main power on.
• Protection against frequent starting.• Wait for 3 or 4 minutes for the compressor to start operating
by itself.
• The air filter is dirty.• The doors or windows are opened.• The air suction and discharge of both indoor and outdoor units
are clogged or blocked.• The regulated temperature or temperature setting is not high
enough.
• Odour may be caused by cigarrettes, smoke particles, perfumeand others, which might have adhered onto the coil.
• Contact the nearest dealer for coil cleaning.
• This is caused by air humidity after an extended period of operation.
• The set temperature is too low, increase the temperature settingand operate the unit at high fan speed.
• Switch off unit and call dealer. This might be due to tiltedinstallation.
• Refrigerant fluid flowing into the evaporator coil.
• Check the fault indication listed under section INDICATOR
LIGHTS.
• If LED display indicates defrost operation, ignore it. Thisshows that the outdoor unit is defrosting the ice at the outdoor unit.
• For other LED display, follow the COMPRESSOR STOPPED
TROUBLESHOOTING INSTRUCTIONS at next section.
• Power failure or fuse needs to be replaced. Check power supply.
• The main power plug is disconnected or the circuit breakingis turned off.
• It is possible that the delay timer has been set incorrectly.• If the problem persist after all these verifications, follow the
COMPRESSOR STOPPED TROUBLESHOOTING
INSTRUCTIONS at next section.
Fault ConditionsThe air conditioner unit will not start straightaway after a power failure or restart of unit.
The compressor does not operate 3 minutes after the air conditioner unit is started.
The air flow is too slow or room cannot becooled sufficiently.
Discharge air flow has bad odour.
Condensation on the front air grille of the indoor unit.
Water flowing out from the air conditioner unit.
Hissing air flow sound from the air conditioner unit during operation.
The indoor unit’s LED indication keeps blinking.
The outdoor unit will not operate and the indoor unit’s LED indication does not blink.
No.1.
2.
3.
4.
5.
6.
7.
8.
9.
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 24/281-17
1 Outdoor Ambient Sensor Error Check ambient sensor wire and connection
2 Outdoor Coil Sensor Error Check coil sensor wire and connection
3 Outdoor Discharge Sensor Error / Check discharge sensor wire and connection / Compressor Overheat Indication Not enough refrigerant / Indoor overload / Outdoor fan
not functioning
4 DC Compressor Feedback Call local dealer
5 Communication Error Check Interconnection communication wire
6 Over Current Call local dealer
7 No Load Check compressor wire and connection
8 Over / Under Voltage Check power supply9 DC Compressor Start Failure Call local dealer
10 Cooling Overload Check whether outdoor unit is blocked or not
11 Defrost Wait till defrost is over then restart
12 IPM Protection Check IPM
13 EEPROM Read Error Change EEPROM
14 EEPROM Write Error Change EEPROM
15 DC Fan Motor Feedback Error Check fan motor wire connection
16 AC Peak Current Error Call local dealer
17 Outdoor Suction Sensor Error Check suction sensor wire and connection
19 DC Compressor Speed Control Error Call local dealer 21 Outdoor Suction A Sensor Error Check A suction sensor wire and connection
22 Outdoor Suction B Sensor Error Check B suction sensor wire and connection
23 Outdoor Suction C Sensor Error Check C suction sensor wire and connection
24 Outdoor Suction D Sensor Error Check D suction sensor wire and connection
31 Indoor A Communication Error Check Interconnection communication wire to Indoor A
32 Indoor B Communication Error Check Interconnection communication wire to Indoor B
33 Indoor C Communication Error Check Interconnection communication wire to Indoor C
34 Indoor D Communication Error Check Interconnection communication wire to Indoor D
Compressor Stopped Troubleshooting Instructions
DO NOT TOUCH ANY OF THEWIRES INSIDE THE UNIT!
Count the number of blinksindicated by the LED
* If the problem still persist, contact your local dealer straight away.
Notice the Yellow LED on the P.C. Board
Open up the Outdoor Unit’s Top Panel or Service Panel
Keep the Main Power Supply ON
Blink Fault Indication Corrective Action
➝
➝
➝
➝
➝
10
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 25/281-18
E n g
l i s h
Normal Running Mode Condition11
If the air conditioner unit has no faulty indications and the compressor is running at normal mode, the outdoor P.C.Board’s LED indication will blink at a slower paste. The table below shows the significant meaning of differentrunning mode and limitation for this air conditioner unit.
One must not attemp to see the LED indication blinking unless instructed to do so.
Blinks Blinking Indication
1 Normal Running, with no limitation2 Voltage Limit
3 Cooling unit : Outdoor Coil Temperature Limit
4 Total Current Limit
5 Discharge Temperature Limit
6 Cooling unit : Indoor Coil Temperature Limit
7 Indoor Fan Control
8 Outdoor Frequency Adjustment
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 26/281-19
MEMO
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 27/28
7/26/2019 Ac Intgerver Multi Split Installation Manual
http://slidepdf.com/reader/full/ac-intgerver-multi-split-installation-manual 28/28
OYL MANUFACTURING COMPANY SDN. BHD.
• In the event that there is any conflict in the interpretation of this manual and any translation of the same in any language,the English version of this manual shall prevail.
• The manufacturer reserves the right to revise any of the specification and design contain herein at any time without prior notification.
• En cas de désaccord sur l’interprétation de ce manuel ou une de ses traductions, la version anglaise fera autorité.
• Le fabriquant se réserve le droit de modifier à tout moment et sans préavis la conception et les caractéristiques techniquesdes appareils présentés dans ce manuel.
• Im Falle einer widersprüchlichen Auslegung der vorliegenden Anleitung bzw. einer ihrer Übersetzungen gilt die Ausführungin Englisch.
• Änderungen von Design und technischen Merkmalen der in dieser Anleitung beschriebenen Geräte bleiben dem Hersteller jederzeit vorbehalten.
• Nel caso ci fossero conflitti nell’interpretazione di questo manuale o delle sue stesse traduzioni in altre lingue, la versionein lingua inglese prevale.
• Il fabbricante mantiene il diritto di cambiare qualsiasi specificazione e disegno contenuti qui senza precedente notifica.
• En caso de conflicto en la interpretación de este manual, y en su traducción a cualquier idioma, prevalecerá la versióninglesa.
• El fabricante se reserva el derecho a modificar cualquiera de las especificaciones y diseños contenidos en el presentemanual en cualquier momento y sin notificación previa.
• В случае противоречия перевода данного руководства с другими переводами одного и того же текста,
английский вариант рассматривается как приоритетный.
• Завод-изготовитель оставляет за собой право изменять характеристики и конструкцию в любое время
без предварительного уведомления.
top related