1
Model Remarks
Introduction and Features
Fengshen Series
2
COOLING HEATING
42000 /4314 /5764 /
/ /
Sound Power Level dB (A)(H/M/L)***Dimension (H/W/D) ( mm)Dimension of Package(H/W/D) (mm)Net Weight /Gross Weight(kg)
Swing Motor ModelOutput of Swing Motor (W)Fuse (A)Sound Pressure Level dB (A)(H/M/L)
EvaporatorPipe Diameter (mm)Row-Fin Gap(mm)Coil length (l) x height (H) xcoil width (L)
Fan Motor Capacitor (uF)Fan Motor RLA(A)Fan Type-PieceDiameter-Length (mm)
Model of Indoor UnitFan Motor Speed (r/min)(H/M/L)Output of Fan Motor (w)Input of Heater (w)
1790 x 540 x 380
1960 x 670 x 475
58/72
ModelFunctionRated VoltageRated FrequencyTotal Capacity (Btu/h)Power Input (W)Rated Input (W)
4PCB 3.15A Transformer 0.2A
53
/
Φ73-1.5
839.5 x 430x43
SM016
Indoorunit
KF-120L/A21-M
460/420/380
100/
4.5/
Centrifugal Fan-1Φ379x180.5
Aluminum fin-copper tube
5.0/
Dehumidifying Volume (l/h)EER / C.O.P (W/W)
KF-120LW/A21-M
380V 3N~
Rated Current (A)
Air Flow Volume (m3/h) (H/M/L)**
50Hz
1500
Specifications and Technical Parameters
In case of any change of parameter data ,refer to the actual data specified on the nameplate of the unit.
KF-120W/lA21-M JT160BCBY1L
scroll65.8
/3750
InternalCapillary
Capacitor
–7 ~ 43Alum inum fin-copper tube
Φ9.522-1.8
1218X658X224
840
68/
3.5
/
Axial fan –2Φ450
Auto defros tT1I
IP24
2.5
0.6
60
/
1250 x 950 x 412
1280 x 1110 x 450
112/123
R22 / 3.85
Φ12Φ19
510
Connection Pipe
OuterDiam eterMaxDis tance
Length (m )Liquid Pipe (m m )Gas Pipe (m m )Height (m )Length (m )
Dim ens ion (H/W/D) ( m m )Dim ens ion of Package(H/W/D) ( m m )Net Weight /Gross Weight(kg)Refrigerant Charge (kg)
Perm iss ible Excess iveOperating Pressure for thePerm iss ible Excess iveOperating Pressure for theSound Pressure Level dB (A)(H/M/L)Sound Power Level dB (A)(H/M/L)
Defros ting MethodClim ate TypeIsolationMois ture Protection
Fan Motor Capacitor (uF)Air Flow Volum e of OutdoorUnitFan Type-PieceFan Diam eter (m m )
Coil length (l) x height (H) xcoil width (L)Fan Motor Speed (rpm )(H/M/L)**Output of Fan Motor (W)Fan Motor RLA(A)
Working Tem p Range (℃)CondenserPipe Diam eter (m m )Rows-Fin Gap(m m )
Outdoorunit
Model of Outdoor UnitCom pressor ModelCom pressor TypeL.R.A. (A)Com pressor RLA(A)Com pressor Power Input(W)Overload ProtectorThrottling MethodStarting Method
In case of any change of parameter data ,refer to the actual data specified on the nameplate of the unit.
Fengshen Series
COOLING HEATING
42000 445004650 43006100 8500
/ /
Sound Power Level dB (A)(H/M/L)***Dimension (H/W/D) ( mm)Dimension of Package(H/W/D) ( mm)Net Weight /Gross Weight(kg)
Swing Motor ModelOutput of Swing Motor (W)Fuse (A)Sound Pressure Level dB (A)(H/M/L)
EvaporatorPipe Diameter (mm)Row-Fin Gap(mm)Coil length (l) x height (H) xcoil width (L)
Fan Motor Capacitor (uF)Fan Motor RLA(A)Fan Type-PieceDiameter-Length (mm)
Model of Indoor UnitFan Motor Speed (r/min)(H/M/L)Output of Fan Motor (w)Input of Heater (w)
1790 x 540 x 380
1960 x 670 x 475
58/72
ModelFunctionRated VoltageRated FrequencyTotal Capacity (Btu/h)Power Input (W)Rated Input (W)
4PCB 3.15A Transformer 0.2A
53
/
Φ73-1.5
839.5 x 430x43
SM016
Indoorunit
KFR-120L/A21-M
530/490/460
10035003.5
/Centrifugal Fan-1Φ379x180.5
Aluminum fin-copper tube
52.58/3.02
Dehumidifying Volume (l/h)EER / C.O.P (W/W)
KFR-120L/A21-M
380V 3N~
Rated Current (A)
Air Flow Volume (m3/h) (H/M/L)**
50Hz
1500
In case of any change of parameter data ,refer to the actual data specified on the nameplate of the unit.
KFR-120W/lA21-MJT160BCBY1L
scroll/
65.83750
InternalCapillary
Capacitor
–7 ~ 43Alum inum fin-copper tube
Φ9.522-1.8
1218X658X224
840
68/
3.5
/
Axial fan –2Φ450
Auto defros tT1I
IP24
2.5
0.6
60
/
1250 x 950 x 412
1280 x1110 x 450
112/123
R22 / 3.75
Φ12Φ19
510
Outdoorunit
Model of Outdoor UnitCom pressor ModelCom pressor TypeL.R.A. (A)Com pressor RLA(A)Com pressor Power Input(W)Overload ProtectorThrottling MethodStarting MethodWorking Tem p Range (℃)CondenserPipe Diam eter (m m )Rows-Fin Gap(m m )Coil length (l) x height (H) xcoil width (L)Fan Motor Speed (rpm )(H/M/L)**Output of Fan Motor (W)Fan Motor RLA(A)Fan Motor Capacitor (uF)Air Flow Volum e of OutdoorUnitFan Type-PieceFan Diam eter (m m )Defros ting MethodClim ate TypeIsolationMois ture ProtectionPerm iss ible Excess iveOperating Pressure for thePerm iss ible Excess iveOperating Pressure for theSound Pressure Level dB (A)(H/M/L)Sound Power Level dB (A)(H/M/L)Dim ens ion (H/W/D) ( m m )Dim ens ion of Package(H/W/D) ( m m )Net Weight /Gross Weight(kg)Refrigerant Charge (kg)
Connection Pipe
OuterDiam eterMaxDis tance
Length (m )Liquid Pipe (m m )Gas Pipe (m m )Height (m )Length (m )
In case of any change of parameter data ,refer to the actual data specified on the nameplate of the unit.
3 Component Name
Air out
Display screen
Front panel
Air-in panelRemote controller
Air outlet
Air in
Sealing tapeDisplay screen
Air in
Connecting pipe
Drainage pipe
Air out
4 Overall and Installing Dimension
Overall and Installing Dimension of Indoor Unit
>30cm
>5cm
Rear
>4cm
>25cm Front>200cm
>25cm
Pipe Side:30cm at least
Fengshen Series
Overall and Installing Dimension of Indoor Unit
Unit: mm
Over 600
Over 600Over 600
Over 600
Nut Bolt
Wrench
55555 Electrical Diagram
In case of any change in the Electrical Diagram shown above, please follow the drawing on cabinet.
Fengshen Series
Controller Function Manual and Operating Instructions
6.1 Controller Function Manua 1 6.1.1 Temperature Parameters Indoor preset temperature (Tpreset) Indoor ambient temperature (Tamb.)
6.1.2 Basic Functions Once started under any mode, the compressor will keep running within 6 minutes. Once stopped, it cannot be restarted until after 3-minute lag. 6.1.2.1 Cooling Mode 6.1.2.1.1 Cooling Conditions and Process When Tamb.≥Tpreset+1 , the unit will run under cooling mode, in which case the compressor and outdoor fan will be ℃
started, the indoor fan will run at preset speed. When T amb≤Tpreset -1 , the unit will be stopped under cooling mode,℃ in which case the compressor and outdoor fan will be stopped and the indoor fan will run at preset speed. When Tpreset -1 <T℃ amb.< Tpreset +1 , the unit will maintain its original operating status.℃
6.1.2.2 Dehumidifying Mode 6.1.2.2.1 Dehumidifying Conditions and Process When T amb. Tpreset +2 , the unit will run under cooling mode, in which case the compressor and outdoor fan will be ℃started, the indoor fan will run at low speed. When Tpreset -2 ≤T℃ amb.≤Tpreset +2 , the compressor, and outdoor unit will run 6 minutes and stop 4 minutes in repeated ℃cycle, while the indoor fan will run at low speed.
When T amb.< Tpreset -2 , the c℃ ompressor and outdoor fan will be stopped. Indoor fan will run at low speed.
Under this mode, the switchover vlave can not be energized, and the temperature can be set within a range from 16
to 30 .The initial value is 25 .
Under this mode, the switchover vlave can not be energized, and the temperature can be set within a range from 16 to
30 .The initial value is 25 .The fan speed is forced to low sepped and unadjustable.No response if FAN button ispressed (including front panel and remote controller's).
Tpreset +1℃
Tpreset -1℃
Start cooling
Original operating status
Stop cooling ≥6 min.≥6 min. ≥3 min.
Tamb
Compressor
Outdoor fan
Indoor fan Preset speed
Run Stop
Compressor
Outdoor fan
Indoor fan
Run
Stop
Cooling
Dehumidifying
low speed
6 min.
Stop
6 min. 6 min. 4 min. 4 min.
low speed
Tpreset +2℃
Tpreset -2℃
amb.
66666
If T amb.≥Tpreset +1 , the compressor and outdoor fan will be stopped, the switchove℃ r valve will remain energized and the indoor fan will stop after 10s when it runs at low speed.When Tpreset -1 <T℃ amb.< Tpreset +1 , the unit will maintain its original operating status.℃
Under heating mode, the temperature can be set within a range from 16 to 30 . The initial value is 25 .℃ ℃ If the unit is switched off under heating mode or switched from heating mode to another mode, the 4-way valve will be de-energized after 2-minute lag.For the first startup of compressor , the exhaust protection will be shielded for 1 min.
6.1.2.5 AUTO Mode Under this mode, the system will automatically select its run mode (cooling, dehumidifying, heating or fan) with the change of ambient temperature. Once a mode is started, the unit will run at least 30 seconds before it can the run status under auto mode according to the ambient temperature. 6.1.3 Other Control 6.1.3.1 Sleep Function If the controller is under cooling or dehumidifying mode, the preset temperature will be increased by 1 one hour ℃
after running under sleep mode and will be increased by another 1 after two hours. The temperature will increased ℃
by 2 within two hours. After that, the unit will run at this temperature. ℃
6.1.2.3 Heating Mode (no this mode for cooling only unit)
When T amb.≤Tpreset -1 , the unit will run under heating mode, in ℃ which case the switchover valve, compressor and outdoor fan will be started, while the indoor fan will run in 90s at most.
6.1.2.3.1 Cooling Conditions and Process
�
Tpreset +1℃
Tpreset -1℃
Compressor
Outdoor fanIndoor fan
Switchover valve
Tamb
6 min.3 n.
Run Stop
Start heating
Original operating status
Stop heating
low
6min. 6min.3min.
Low speed
6.1.2.3.2 Defrosting Conditions and Process When detecting any frost in condenser, the system will start defrost, in which case the compressor will continue to run,andoutdoor fan,4-way valve and indoor fan stop running.The auxiliary electric heater,if any, will be stopped firstly. After 1-min lag, the switchover valve, indoor fan and outdoor fan will be stopped. Upon detecting completion of defrosting,the outdoor fan and 4-way valve will stat to run simultaneously,the indoor fan will run in 90s at most(overcurrent protection can not bedetected),and the compressor will maintain its original operating status.
Defrosting Notice:If auxiliary electric heater is stopped ,the indicator will blink and place for displaying ambient and presettemp.Once defrosting is completed ,the display of ambient will come back.
Compressor
Outdoor fan Indoor fan
During defrosting
4-way valve
Run Stop
6.1.2.4Fan Mode Indoor fan will run at preset speed
Auto Low Medium High
The temperature can be set within a range from 16 to 30 . The initial value is 25 .�
Fengshen Series
Set the Temperature Tpreset
℃
T Bpreset B
T Bpreset B+2℃
T Bpreset B+1℃
1 hour 2 hours Over 2 hours
T Bpreset B
T Bpreset B-1℃
T Bpreset B-2℃
1 hour 2 hours Over 2 hours
Set the Temperature Tpreset
If the controller is under heating mode, the preset temperature will be decreased by 1 one hour after running under ℃
sleep mode and will be decreased by another 1 after two hours. The temperature wi℃ ll decreased by 2 within two ℃
hours. After that, the unit will run at this temperature.
No sleep function under FAN or AUTO mode,and it can not be set.
1.The controller with setting temp display will display temp with the change of it after sleep function is set.
3.After the sleep function is set,if press buttons except sleep button on the panel ,the sleeping time won't been recalculated,
if press buttons of the remote control ,it will be recalculated.
2.Sleep setting will be cleared upon switchover between modes, press of temp button on front panel and stop of unit, what'smore, sleep function can not be memorized.
6.1.3.2 Timer ON/OFF function 6.1.3.2.1Timer ONWhen the timer is set to ON, the system will be under Timer OFF status. At the time for Timer ON, the controller will remain under its preset mode. The time interval for Timer ON or OFF is 0.5h, and can be set within 0.5 - 24 hours.
You can set Timer OFF function when the unit is under ON status. Upon the time of Timer OFF the system will be switched off. The time interval for Timer OFF is 0.5h, and can be set within 0.5 - 24 hours.
6.1.3.2.2Timer OFF
6.1.3.2.3 Others1.If the remote control can display timing ,the timing is unnecessary to decrease after it is set.2.If timing is set,if repress buttons except TIMER on front panel or remote control ,the timing should be recalculated.
3.When controller for cooling only receives signal of stopping the unit of remote-control heating and after the unit is stopped,
time reaches,the whole unit will run under the running status before stop of the unit.
if set Timer ON of the unit by remote controller, the controller will receive the signal and setting is available.Once setting
6.1.3.3 Control of Swing Motor
Control it on or off with the swing key.If the indoor fan stops running ,the swing motor mustn't be started.
If the controller is powered on or receives the signal sent by the valid keys , the buzzer will beep.
6.1.3.4 Buzzer
Under this mode ,the indoor fan will automatically select high,mid,or low speed with the change of ambient temp,once
6.1.3.5 Auto Fan Speed Control of Indoor Fan
started,each of the speed can be switched by conditions in at least 30S.
indicator will blink every 6 sec.Different times of blink indicates different kind of protection.
E1: High pressure protection of compressor: once;
E2 : Indoor anti-freezing protection: twice;
E3: Low pressure protection of compressor: 3 times;
E4: High temperature protection of exhaust hose: 4 times;
E5: Overcurrent protection :5 times ;
E6 : Static dedusting protection: 6 times,defrosting: 7 times;
6.1.3.6 Indicator Control
If the controller is energized, the indicator will be red under standby status.Any one of the following cases happens,green
The indicator is always blinking under forcible cooling or heating;
Memory content, Mode ,Swing, Set temp., Set fan speed,air change,Timer (if timing hasn't arrived and power is off, when the
power is on, the timing will be recalculated; If timing has arrived and the power is off, the unit will run at the mode upon the timing after powered on.
Upon powered on after powered off ,the unit can automatically start by the memory content.
6.1.3.6 Power-off Memory
Press the mode button and select the mode as follows :
Auto,Cool,Dehumidify,Fan ,Heat (Cooling and heating type) Auto,Cool,Dehumidify,Fan( Cooling only type)
6.1.4.1 Mode Button
Press the fan speed button and select as follows:Auto,low,mid,hi
Under dehumidify mode,the fan speed is unadjustable.
6.1.4.2 Fan Speed Button
1.Every press of the temp button or ,setting temp will increase or decrease by 1 ,and adjustable temp range is 16 to
30 .Under auto mode,these buttons are invalid.If simultaneously press them,the function of all buttons on the panel willbe shielded, if repress them again,the shield function will be released.
6.1.4.3 Setting Temp Button (Temp and )
If heat mode is diplayed on the handset used to control the unit and the air conditioner is cooling only type,the unit will not6.1.4 Buttons
accept any signal except for turning off the unit.
If press the invalid buttons (anion,humidity, energy saving ),the buzzer will not respond,but for reserved air exchange it beeps.
The relay works after pressing the buttons 2 s.
�
�
2. For the first energization of the unit, if any valid button does not be pressed:
1) If press , the unit will immediately enter into forced heating operation , all loads will be started, indoor and outdoor fan will
run at high speed and all characters will be displayed.If it is detected that ambient temp or evaporator tube temp is too high or
low, the buzzer will beep.The unit will stop under normal standby status in 5 min.
2) Under OFF status of the unit,pressTimer button to set Timer on, and under ON status of the unit , press this button to set
Timer off.Matching wiith and ,if press this button, Timer,ON/OFF, Time, Hr will blink and then press or ,the timing will be increased or decreased by 0.5hr.3) If press , the unit will immediately enter into forced cooling operation , all loads except 4-way valve will be started, indoor and outdoor fan will run at high speed and all characters will be displayed.If it is detected that ambient temp or evaporator
tube temp is too high orlow, the buzzer will beep.The unit will stop under normal standby status in 5 min.� The above functions are only for test.
There is not forced heating for cooling only unit.
If press Timer button ,Timer,ON/OFF,hr and time will blink,in which case,adjust the timing through the buttons and .The6.1.4.4 Timer Button
setting range is 0.5 to 24 hr.If press timer again to confirm timer, the mark of Timer on /off will be displayed but not blink.PressTimer again to cancel , but Timer on/off,the mark of Timer on /off won't display.If not pressing Timer to confirm,the unit will
If pressTimer button for the first time,Timer,ON/OFF,hr and time will be displayed by 0.0 hr (press Timer again to cancel ).Presswhen setting time is 24hr, or press when setting time is 0.5hr.If timer display is 0.0 hr, press Timer again to cancel.
iresume its original setting in 10s.
If press Swing button once and indoor fan has run, swing motor will run.Repress this button, swing motor will stop running.6.1.4.5 Swing Button
If press Light button once,LED will display it.If repress it ,all displays on the screen except running indicator will be closed and6.1.4.7 Light Button(on displayer)
The LED can be controlled by the light button on the handset:if the light is valid,the screen display is valid;By the contraty,the6.1.4.8 Light Button(on remote control) LED lights,which is cycled like this.Every time of startup of the unit ,the light will be defaulted on .
light is invalid,all displays on the screen except running indicator will be closed.
It controls On and Off of controller.Every press of it, the on and off state will switch.
6.1.4.6 ON/0FF Button
Fengshen Series
� For floor standing unit with back light, its on or off can be controlled by Light button and it is allowed to on only there is display.
For floor standing unit with light case, its on or off can be controlled by Light button.
If the power is on, only power incon at the right lower corner is displayed under off status of the unit.
6.1.5 Icons Display
After starting the unit by remote controller or buttons, present setting running moe(cool,heat,dehumidify,fan,auto) will be displayed,
6.1.5.1
6.1.5.2 Mode Icon Display
and seting temp will also be displayed in tx seconds.
The small sector indicators will light or black orderly (circularly display).6.1.5.4 Swing Display
different for different fan speed for knowledge of speed.The internal small sector indictors are all light .
Corresponding fan speed(low,mid,high, auto) and dynamic sector icons will be displayed.The area of external big sector is6.1.5.3 Fan Speed Display
Middle speed:five-layer icon lights or blacks orderly from inner to outer --circularly displayLow speed:three-layer icon lights or blacks orderly from inner to outer --circularly display
High speed:seven-layer icon lights or blacks orderly from inner to outer --circularly display
Under auto mode,the unit will select low,mid or high fan speed and display corresponding icon according to detected temperature.
If the unit hasn't received timing signal for continuous 9s during timer setting,the timer display will disappear.6.1.5.5 Timer Display
During stop of the unit:if timer on is set,clock, ON, hr and corresponding timing will be displayed. During start of the unit:if timer off is set,clock, OFF, hr and corresponding timing will be displayed.
6.1.5.5 Sleep The crescent icon will be displayed during setting the sleeping.
When the light function is off,it only power icon is displayed.�
6.1.5.6 Low-voltage Protection
When the conpressor is running,and it is detected that the current exceeds 25A,the unit will stop by the indoor ambient temperature reaching preset temp.After the conpressor hasn¡¯t runned for 3 min.,the unit will automatically resume its
original running status.If there are more than 6 times protection (If the compressor hasn¡¯t runned for more than 6 min.,the times of protection will be cleared),theindicator light flickerd,and the unit not resume its original running status,so
press the ON/OFF key to stop the unit and repress the key to resume operation.
5.Under heat mode,if compresoor is running while outdoor fan is stopped(Hi-temp. protection),the detection will be shield till the outdoor fan resumes running.
4.Under heat mode,if the outdoor ambient temp. is lower than 0 or equal to 0 ,this detection will be shielded.
low,the system will enter into antifreeze protection status, in which case,the indicator will blink ,E2 will be displayed at the place
6.1.6 Protection 6.1.6.1 Indoor Antifreeze Protection When the unit is cooling under cool or dry mode(T amb Tpreset +2 ) , if it is detected that the evaporator tube temp is too
Thebuttons will not be shielded under antifreeze protection.been stopped for 3 min, the indicator will black, display will be resumed and the controller will run under setting mnode.
6.1.6.2 Compressor High-pressure Protection If high-pressure protection (including under off state of the unit) is detected in 3 successive seconds, the unit will close all loads
that compressor high-pressure protection is released in seccessive 6 seconds, the indicator will still blink and E1 will be displayed, in which case you have to press ON/OFF button to switch off the unit before you can clear E1 display and turn off the indicator. Repress ON/OFF button to resume the operation. 6.1.6.3 Compressor Low-pressure Protection
and shield all buttons and remote-control signal,meanwhile,the indicator will blink and only E1 will be displayed.If it is detected
, the complete unit will be stopped and the Indicator will blink. In 3 minutes, the unit will resume running automatically. If
1.After the compressor is started for 3min, if it is detected for 3 minutes successively that the low-pressure switch is broken
and repress it again to resume operation.the unit won't resme running automatically so as to remind the user of air leakage. Press ON/OFF button to switch off the unit low-pressure switch protection occurs 2 times successively, the indicator will blink and only E3 be displayed ,in which case
minutes later.
2.Under defrost mode, low-pressure switch signal can not be detected,which should be done after defrosting is finished 10
detection by pressing ON/OFF key to switch off the unit and pressing it again to start the unit. low pressure switch signal for purpose of air collection. Detection will resume automatically after 6 minutes,or you can resume 3.From the controller, you can press down SWING button and FAN SPEED button simultaneously to shield the detection of
where ambinet temp(if no,setting temp) is displayed and the other displays will also be kept.The compressor,outdoor fan,indoor fan and swing motor will keep their original status. When the evaporator tube temp resumes normal and the compressor has
will be stopped,the indicator blink and only E3 be displayed, in which case the unit cannot be restarted automatically. You 6.If it is detected that the low-pressure switch is off in successive30s when the compressor is stopped, the complete unit
have topress ON/OFF button to switch off the unit and press this key again to restart. 6.1.5.4 Exhaust Pipe High-temp. Protection
After the compressor is started, if the exhaust temperature is too high or exhaust sensor is in short circuit (or open circuit), the indicator will flickerand the unit will be stopped when the indoor ambient temperature reaches the preset value.After the compressor is stopped for 3 minutes, the complete unit will be restarted when the exhaust
temperature is resumed to normal. If above phenomena occurs twice continuously, the complete unit cannot be restarted automatically, the indicator will
blink and E4 will be displayed. Press ON/OFF key to switch off the unit and press it again to switch on the unit. If the exhaust temperature is normal, the unit will run under preset mode.
6.1.5.6 Low-voltage Protection
When the conpressor is running,and it is detected that the current exceeds 25A,the unit will stop by the indoor ambient temperature reaching preset temp.After the conpressor hasn¡¯t runned for 3 min.,the unit will automatically resume its
original running status.If there are more than 6 times protection (If the compressor hasn¡¯t runned for more than 6 min.,the times of protection will be cleared),theindicator light flickerd,and the unit not resume its original running status,so
press the ON/OFF key to stop the unit and repress the key to resume operation.
6.1.5.5 Indoor ultra-high temp. protection Under heating mode, if it is detected the temp. of evaporator pipe is too hi.,the outdoor fan will stop(defrosting won't be detected),if temp. gets right, outdoor fan will start running(defrosting will be detected).
6.1.5.7 Fault Code
Fault Code Definition E1 Compressor High-pressure Protection E2 Indoor Antifreeze Protection E3 Compressor Low-pressure Protection E4 Exhaust Pipe High-temp. Protection E5 Low-voltage Protection
Fengshen Series
77777
Disassemble Air-in Panel
Use screwdriver to unscrew the holding screw at the air-in frame, and forcefully pull out the air-in grill.
Fig.7-1
Screw
Operating Procedures / Photos
Disassemble Electric Box Cover
Unscrew the screws on the elctric box cover to remove it.
Fig.7-2
Fig.7-1
Fig.7-2
Screw
Temp sensor
Disassemble Front Panel
Unscrew the two screws fixing the front panel, and make the air-in panel off the clasp, disconnect the wiring terminals to remove the front panel. Fig.7-3
Screw
Fig.7-3
Disassembly Process of Indoor Unit
Disassembly and Assembly Procedures
Disassemble Air Outlet Assy
Unscrew the 3 screws connecting the air outlet and
top cover and 2 screws connecting left and right side
plate.
Fig.7-4,7-5
Air Outlet Assy
Fig.7-4Screw
Air Guard
Fig.7-5
Disassemble Air Guard
Unscrew the 12 screws on the air guard to remove theair guard.
Fig.7-6
Screw
Screw
Fig.7-6
Disassemble Electric Box
Unscrew the three screws at the electric box and pull out each terminals as shown in the figure to remove the
electric box.
Fig.7-7
Screw
Fig.7-7
Operating Procedures / Photos
Fengshen Series
Disassemble Chassis and Top Cover
Unscrew the 4 screws fixing air-in joint plate to remove it.
Unscrew the 3 screws fixing the mounted plate of water
tray to remove it.Fig.7-8
Air-in joint plate
Mounted plate
Screws
Fig.7-9
Unscrew the 2 screws fixing protective top cover to remove
Unscrew the 5 screws fixing the chassis to remove it.
Fig.7-9,7-10
Fig.7-8
Screws
Fig.7-10
Screws
Disassemble Protective Top Cover
Unscrew the 7 screws fixing top cover to remove it.
it.Pull out tube temp sensor.
Fig.7-11
ScrewsProtective Top Cover
Fig.7-11
water tray
Operating Procedures / Photos
Disassemble Auxiliary Electric Heater Assy
Unscrew the screws fixing the auxiliary electric heater Unscrew the 2 screws fixing the guard grill to remove it.
Only for cooling and heating unit
assy.and loosen the tie lines to remove it.
Fig.7-12
Guard grill
Auxiliary electric heater
Fig.7-12
Disassemble Evaporator
Unscrew the screws fixing the evaporator, and then pullUnscrew the 2 screws fixing the guard grill to remove it.
out the right and left side plate to remove the evaporator. Evaporator
Capillary assy
Disassemble Water Tray Assy
Remove the mounted plate of water tray and put out the right and left side plate to remove the water trayupwards. Water tray
Fig.7-13
Fig.7-13
Fig.7-14
Fig.7-14
Operating Procedures / Photos
Fengshen Series
Disassemble Guide Ring and Centrifugal Fan
Unscrew the nut in the middle of the centrifugal fan toTurn the guide ring clockwise to a position to remove it.
remove it. Fig.7-15
Guide ring
Centrifugal fan
Nut
Fig.7-15
Disassemble Propeller Housing and Mtor
it.Unscrew the nut fixing the motor to remove it.
Unscrew the screws fixing the propeller housing to remove
Fig.7-16
Propeller housing
Screw
Nut
Motor
Fig.7-16
Operating Procedures / Photos
Disassembly Process of Outdoor Unit
Operating Procedures / Photos
Disassemble Rear Grill
Screw off the six tapping screws at the rear side plate, valve support chassis and condenser side plate to remove the rear grill. Fig 7-17
Disassemble Top Cover Plate
Screw off the tapping screws around the top cover, and then pull the top cover upward to remove it. Fig 7-18
Disassemble Front Side Plate
Screw off the three tapping screws at the front side plate, and then pull the front side plate upward to remove it.
Rear Grill
Screw
Screw Top Cover
Fig 7-18
Front Side Plate
Screw
Fig 7-19
Fig 7-17
Fig 7-19
Fengshen Series
Operating Procedures / Photos
Disassemble Cabinet
Unscrew the screws around the cabinet to remove the cabinet. Fig 7-20
Disassemble Electric Box
Unscrew the screws around the electric box sub-assy to remove it. Fig 7-21
Disassemble Right Side Plate
Unscrew the screws around the right side plate to remover the right side plate. Fig 7-22
Screw
Cabinet
Fig 7-20
Screw
Fig 7-21
Right Side Plate
Screw
Fig 7-22
Operating Procedures / Photos
Disassemble Axial Flow Fan
Use spanner to twist off the nut of the fan and remove the fan. Fig 7-23
Disassemble Outdoor Motor
Unscrew the screws around the electric box sub-assy to remove it. Fig 7-24
Disassemble 4-Way Valve
Screw off the holding nut of the 4-way valve coil and remove the coil. Use wet cotton cloth to wrap the 4-way valve, unsold the four soldering points connecting the 4-way valve, and remove the 4-way valve. Be quick during the unsoldering process, pay attention to keep the wrapping cloth wet and do not allow the soldering flame to burn the compressor lead-out cable. Fig 7-25
Nut
Nut
Fig 7-23
Motor
Screw Fixing the Motor
Motor Support
Fixing Screw
Fig 7-24
4-Way Valve
Fig 7-25
Fengshen Series
Operating Procedures / Photos
Disassemble Valve
Unscrew the two screws fixing the valve, unsolder the connecting pipe of the valve, and remove the valve. Fig 7-26
Disassemble Capillary
Unsolder the soldering points between the capillary and other pipes to remove the capillary. Fig 7-27
Disassemble Compressor
Unscrew the four foot screws of the compressor and unsolder the connecting pipe to remove the compressor. Fig 7-28
Screw Liquid Valve Gas Valve Screw
Fig 7-26
Capillary
Fig 7-27
Foot Screw
Fig 7-28
8
1
28 27
2
26 19~2425 18
17 16
10 11
11
3 4 5 6 7
15
13
9
14
8
A
A
Exploded View and Components and Parts List
Exploded View of Components and Parts of Indoor Unit
Fengshen Series
KF-120L/A21-M KFR-120L/A21-M1 Underpan 22224432 22224432 1 2 Left Side Plate Assy 01304278 01304278 1 3 Rear Plate Assy 01304277 0130427701 1 4 Top Cover Assy 22244437 22244437 1 5 Right Side Plate Assy 01304279 01304279 1 6 Evaporator Assy 010044461 010044461 1 7 Water Tray Assy 12414210 12414210 1 8 Assistant Heater Assy / 32004401 19 Air Guard Assy 01364436 01364436 1 10 Air Outlet Assy 200044344 200044345 1 11 Air Louver 10524431 10524431 6 12 swing motor 15214215 15214215 113 Air Guider 10514435 10514435 614 Display Board 305434511 305434501 1 15 Panel Assy 20004433 20004433 1 16 Air Intake Assy 200044371 200044371 1 17 Filter Assy 11124432 11124432 1 18 Main Board 30033051 30033050 1 19 Electric Box 01404211 01404211 1 20 Terminal Board (5位) 42010258 42010258 1 21 Transformer SC28D 43110237 43110237 1 22 Fan Capacitor 33010010 33010010 1 23 Senor Insert 42020063 42020063 1 24 4 Core Sensor 39000190 390001372 1 25 Diversion Circle 10374435 10374435 1 26 Snail Shell 12104444 12104473 1 27 Centrifugal Fan 10314401 10314401 1
Fan Motor LN100C 15014423 / 1 Fan Motor LN100B / 15014402 1
NO Name of Material QTY
28
Code of Material
Components and Parts List of Outdoor Unit
The above date are subject to change without prior notice
28 27 26
1
43
2
25 24 17
18~23
16
15
14
13
8765 9
10~12
Exploded View of Outdoor Unit
Fengshen Series
KF-120W/lA21-M KFR-120W/lA21-M1 Front Grill 22414102 22414102 22 Cabinet 01435436 01435436 13 Rear grill 01475432 01475432 14 Top Cover 01255262 01255262 15 Condenser Assy 011054362 0110516701 16 Motor Support Assy 01705433 01705433 17 Motor LW92A 15015421 15015421 28 Clapboard Assy 01235440 01235440 19 Gas-liquid Separator 07225433 07225011 110 4-way Valve Assy / 030234321 111 4-way Valve body / 43000405 112 4-way valve coil / 430004002 113 Suction Pipe Assy 03635452 03635446 114 Valve Assy 1/2" 071302362 071302362 115 Valve Assy 3/4" 07103401 07103401 1
Compressor JT160BCBY1L 00100113 00100113 1
Overload Protector built in built in17 Axial Flow Fan 10338731 10338731 218 Electrical Box 01414201 01414201 119 Wire Clamp 71010103 71010102 120 AC Contactor 44010226 44010226 1
21Over Current ProtectorUO-10-16A/16A 46020112 46020112 1
22 Terminal Board 42010258 42010258 123 Capacitor 3.5uF/450V 33010010 33010010 224 Handle 26235253 26235253 325 Valve support Assy 01715002 01715002 126 Rear Side Plate 01303712 01303712 127 Front Side Plate 01305034 01305034 128 Chassis Assy 01205438 01205438 1
NO Name of Material QTY
16
Code of Material
Components and Parts List of Outdoor Unit
The above date are subject to change without prior notice
1 0
Trouble-Shooting
Check insulation resistance for grounding; Confirm if air-conditioning unit has electrical leakage or is short-circuited
Air
–con
ditio
ning
uni
t ca
nnot
be
star
ted
Trip of circuitbreaker orburn-out of fuse
When set circuit breaker as“ON”, it trips immediately
When turning the air-conditioning unit to the“ON”status, trip of circuit breaker occursseveral minutes later
Both indoor unit and outdoor unit do not start
No power supply
Power plug is not firmly seated orconnection is poor
Line connection failure betweenindoor unit and outdoor unit
Emission failure of remotecontroller
Controller fuse burned out
Check if the connection linebetween Hi-volt PCB and Lo-voltPCB is secure
Check if transformer output line issecure and if there is voltage output
Check circuit breaker, measureresistance for short-circuit
Check power supply line
Power plug is not firmly seatedor connection is poor
Check remote controller
Replace controller fuse
Please secure connection line
Check the line connection according tothe electrical diagram and ensurecorrect connection
Secure connection line and check output voltage
Poor
coo
ling
effe
ct
Set temperature is notappropriate
Check if the cooling (heating)load is appropriate
Adjust the set temperature
Check the forecasted cooling (heating)
Failure of refrigerant flow
Insufficient air circulation
volume
4-way valve failure Replace 4-way valve
Insufficient refrigerant Charge refrigerant
Compressor failure Replace Compressor
Insufficient flow in valve Fully open the valve
Clean the filter grill Block in air filter
Fan speed was set too low Set fan speed as high or medium
Mounting position of outdoorunit is inappropriate
Outdoor side shall have good ventilation and installproper weather screen
1 0
Fengshen Series
—91—
Block in filter of indoor unit Periodically clean the filter
Leakage between internal high pressureand low pressure sections of compressor
Replace compressor
Poor
coo
ling
effe
ct
Replace capillary Partial block in capillary
Find out leakage position and chargerefrigerant Leakage of Refrigerant
Burn-out or wire break of indoor fanmotor
Repair or replace fan motor
When air supplymode is selected,the fan does notoperate
Correctly connect lines according toelectrical diagramWrong line connection
Replace it withfan capacitor of thesame model and spec. Open circuit or damage of fan capacitor
Wire break of relay coil Replace relay When in cooling mode, both outdoor unit and compressor do not operate.
Poor contact of relay Replace relay
Adjust the set temperature Improper temperature setting
Replace fan motor Outdoor fan motor is damaged
Wrong line connection
Outdoor fan capacitor is damaged
When in cooling mode, compressor operates but outdoor fan does not operate
Correctly connect lines according toelectrical diagram
Replace fan capacitor
Replace Compressor Compressor failure
When in coolingmode, outdoor fanoperates butcompressor doesnot operate
Operating capacitor of compressor isdamaged
Replace capacitor
It is suggested to equip voltage regulator Voltage is too low or too high
Wrong line connection Correctly connect lines according to drawing
Block or breakage of drainage pipe Replace drainage pipe
Water leakage The refrigerant pipe joint is notwrapped firmly Wrap and bind it again firmly
Fan of indoor unit touches otherpositions
Adjust fan position
Foreign articles inside the indoor unit Remove foreign articles
Vibration of compressor is violent Adjust support foot mat of compressor, tighten loose bolts
Abnormal soundand vibration
Pipes of outdoor unit bump together Separate bumping pipes
Metal plates bump together inside theunit
1. Tighten connection screws2. Attach vibration damping
gum between metal plates
Indoor fan bumps cabinet Adjust fan position
Abnormal sound from insidecompressor Replace Compressor
E1 Compressor High-pressure Protection
E2 Indoor Antifreeze Protection
E3 Compressor Low-pressure Protection
E4 Exhaust Pipe High-temp Protection
E5 Overcurrent Protection
Fault Code
Fengshen Series