african american cultural center/august wilson center ...€¦ · african american cultural center...
Post on 06-Jun-2020
11 Views
Preview:
TRANSCRIPT
Table of ConTenTs (click on link)
General InformaTIon
aaCC renTal spaCe & Venue
Theater
main floor lobby
second floor lobby
Café
education Center / Conference room
Conference room lounge
studio
aaCC seaT CounT and Venue CapaCITy
TheaTer InformaTIon
seating Chart
Technical holds
loCaTIon / approaCh / aCCess
sTaGe door
sTaGe speCIfICaTIons
dimensions
Construction
stage pit
rigging/staging
soft Goods Inventory
line sets
eleCTrICs
dimmers & Circuits
Controls
fixtures
accessories
follow spot booth
light ladders
power disconnects
dimmer schedule
sound
main system
Inventory
Communication
ClearCom
paging/program
Guest Internet/Wi-fi
radio frequency Coordination policy
VIdeo
fIre & pyroTeChnICs
props
Wardrobe & laundry
dressInG rooms
location
Capacity
Green room
sTaGe rIsers / personnel lIfTs
august Wilson center Technical Specifications
Revised november 2015
page 1 of 27
African American Cultural Center/August Wilson CenterTechnical SpecificaTionS
afrICan amerICan CulTural CenTer (aaCC)/auGusTWIlson CenTer General InformaTIon
physical address: 980 liberty avenue
pittsburgh, pa 15222
aaCC stage door: located at William penn place
between liberty avenue
& Seventh avenue
mailing address: aacc in care of:
The pittsburgh cultural Trust
801 liberty avenue
pittsburgh, pa 15222
production department: berne bloom, Director of production 412-456-2635
412-456-2600
Ticketing: 412-456-6666 (public)
Theater stage: The aacc Union contract is with i.a.T.S.e., local #3.
house policies:The pittsburgh fire Department requires theatres to make a pre-show announcement,
ten minutes prior to curtain time, about emergency exit locations. This announcement
may be made live or pre-recorded on cD.
The city of pittsburgh fire code requires a 4' access path to be maintained to all fire protection
equipment such as fire hoses, extinguishers and pull stations.
The aacc is a non-smoking facility. Smoking is not permitted anywhere in the building.
aaCC renTal spaCe & Venue
aaCC TheaTremaIn floor lobbyseCond floor lobbyCaféeduCaTIon CenTer / ConferenCe roomConferenCe room lounGesTudIo
august Wilson center Technical Specifications
Revised november 2015
page 2 of 27
back To Top
back To Top
aaCC seaT CounT and Venue CapaCITy
aaCC TheaTerorchestra level:
orchestra Rows a-G 181
Upper orchestra h-M 127
orchestra (Removable)
pitt Rows aa-bb 28
balcony level:
balcony Rows aa-ee 150
Total seats (including pitt Seats) 486
The aacc is in compliance with the americans with Disabilities act and its requirement that all events and programs are accessible.
maIn lobbyMaximum capacity 1,161
seCond floor lobbyMaximum capacity 253
CaféSeated 85
Standing 175
eduCaTIon CenTer / ConferenCe roomorchestra level:
orchestra Rows a-G 181
Upper orchestra h-M 127
ConferenCe room lounGeorchestra level:
orchestra Rows a-G 181
Upper orchestra h-M 127
sTudIo Maximum capacity
Seated 155
Standing 447
august Wilson center Technical Specifications
Revised november 2015
page 3 of 27
maIn floor lobby
open space located on the aacc main floor, adjacent to the Theatre and café.
exhibition hall, box office and Gift Shop are in the lobby.
size 4,430 sq. ft.
Capacity 1,161 persons
ceiling mounted, speakers capable of program monitoring and music playback are permanently
installed throughout the lobby. Music playback is the same on the first and second floors.
seCond floor lobby
open space located on the second floor of the
aacc, adjacent to the theatre balcony,
education center. Studio, donor lounge and
exhibition hall.
size 1,906 sq. ft.
Capacity 253 persons
ceiling mounted speakers capable of program
monitoring and music playback are permanently
installed throughout the lobby. Music playback
is the same on the first and second floors.
august Wilson center Technical Specifications
Revised november 2015
page 4 of 27
back To Top
Café
aacc café and patio are located at the main floor
of the in The Davenport family fund lobby.
sizecafé 1,600 sq. ft.
patio 700 sq. ft
Capacity 85 seated persons
175 standing persons
Café equIpmenTnot transferrable to other rooms
Gray stackable chairs
White outdoor stackable chairs
30" Round café tables
28" square café tables
august Wilson center Technical Specifications
Revised november 2015
page 5 of 27
back To Top
eduCaTIon CenTer / ConferenCe room
located on the second floor of the aacc
size 2,000 sq. ft.
Capacity 101 seated persons
400 standing persons
equIpmenTStorage closets
Double sink
2' w x 5' l tables on caster that can be used
in several configurations
purple stackable chairs
(1) eiki-lc-WGc 500 projectors – ceiling mounted.
(note: projectors are single source)
(1) Da-lite front projection Screen
projecting Surface: 160" wide x 90" high
white screen with black border
ceiling mounted.
(1) lectern/equipment rack:
(1) creston TpMc-8x Universal control with charging station (controls projectors, projectionscreens, microphones, cD player, DVD/VcR recorder and computers
(1) lG – Rc897T super multi DVD recorder/VcR with digital tuner
(2) audio-Technica aeW-T6100 handheld wireless microphones
(8) listen Technologies lR-400-216 portable display fM receiver – assistive listening
(8) listen Technologies la-164 ear speaker
Data and power outlets are available throughout the room.
august Wilson center Technical Specifications
Revised november 2015
page 6 of 27
back To Top
ConferenCe room lounGe
located on the second floor of the aacc
size 831 sq. ft.
Capacity 56 seated persons
165 standing persons
equIpmenTSamsung 1080p – ln52b630n1fXZa 52’ lcD TV – wall mounted
black leather sofa
black leather club chairs
coffee table
side tables
high cocktail tables
high stools
This room can be used in different configurations.
Data and power outlets are available throughout the room.
sTudIo
located on the second floor of the aacc
size 2.325 sq. ft.
Capacity 155 seated persons
447 standing persons
equIpmenTThis room has sprung hardwood floor
(1) mirrored wall
august Wilson center Technical Specifications
Revised november 2015
page 7 of 27
back To Top
aaCC TheaTer seaTInG CharTorchestra level
august Wilson center Technical Specifications
Revised november 2015
page 8 of 27
back To Top
STAGE
UP
DNEDGE OF STAGE
RAMP(-0'-10")
RAMP(-0'-10")
109 108 107 106 105 104 103 102 10110
621
5
9
13
9
53
1
15
9
51
31
114111 108 105
1012
4
16
10
62
14
10
62
4
14
8
2
18161412108642
101105
101103105107109111112113114115116117118
106110
1357911131517
101104
101
107110113115117
116
1
7
13
3
7 8
4
101102103104105106107108109
12
814
10
62
137
11
15
9
1412
84
101102103104105106107108109110111112113114
101102103104105106107108109110111112113
102103104106107109110112113
15
11
13
57
11
9
37
1113
16
12
86
42
1210
111113
13579
1113
15
359
11
137
1614
12108642
1210
64
102103104105106107108109110111112113114115
116 114 112 111 109 108 106 105 103 102
102
102103104
104106108110
107108109
842
1210
86
42
101102103104105106107108109110111
101102103104105106107108109110111112
12
8
4 1412
108
64
2
14
10
13
57
911
7
11
3
13
57
911
13
9
13
112 110 109 108 107 106 105 104 103 102 101
108642
6
1357
9
5
101102103104105106107108109110
THEATER SEATING CHART - ORCHESTRA
A
B
C
D
E
F
G
H
J
K
LM
BB
AA
A
B
C
D
E
F
G
BB
AA
AS OF 09.16.10NO SCALE
( INDICATES SEAT WITH REMOVABLE ARM)
SUBJECT TO CHANGEFOR SEATING REFERENCE ONLY
H
J
K
LM
TeChnICal holdsin-house mix position is in the center orchestra level in Row G.
consult productions Management office, in advance, if in-house mix position is required.
This involves coordination with box office ticket sales, and additional time and manpower.
Seats will need removed: G105, G106, G107, G108, G109
aaCC TheaTer seaTInG CharTbalcony level
august Wilson center Technical Specifications
Revised november 2015
page 9 of 27
back To Top
101102
103104
105106
107108109110111112113114115116117118119120121122123124125126127128
129130
131132
133134
135136
137
101102
103104
105106107108109110111112113114115116117118119120121122123124125126127
128129
130131
132133
134135
101102
103104105106107108109110111112113114115116117118119120121122123124125
126127
128129
130131
132
101102103104105106107108109110111112113114115116117118119120121122123
124125
126127
128
110111112113114115116117118119123124
127 126
105 104
101102
STAGE
THEATER SEATING CHART - BALCONYAS OF 09.16.10
NO SCALE
( INDICATES SEAT WITH REMOVABLE ARM)
SUBJECT TO CHANGEFOR SEATING REFERENCE ONLY
AA
BB
CC
DD
EE
AA
DD
EE
BB
CC
loCaTIon/approaCh/aCCess
The aacc is located in Downtown
pittsburgh, pennsylvania.
front of house/auditorium is on liberty avenue
Stage roll door and Stage Door are
located stage William penn place between
liberty avenue and Seventh avenue and are
under 24-hour guard service
for navigational search tools, use 980 liberty avenue, pittsburgh pa 15222.
august Wilson center Technical Specifications
Revised november 2015
page 10 of 27
back To Top
sTaGe door
The stage door is located at William penn place between liberty avenue and Seventh avenue.
The dock has a 2’-0” step above stage level and is equipped with one permanently installed
mechanical dock leveler with remote control.
rollInG doorslocation: Upstage Right
Door dimensions: (2) 9'-8" w x 12' h
Dock floor is 1'-2" from street
surface
Trucks: (2) 24' trucks at a time, with (1) dock leveler
leveler capacity: (1) 10,000 lb maximum evenly distributed and centered
load capacity: 5,000 lb maximum side axle capacity
7,500 lb maximum end axle load capacity
Shore power: not available
august Wilson center Technical Specifications
Revised november 2015
page 11 of 27
back To Top
sTaGe speCIfICaTIons
dImensIonsproscenium opening: 40'-0" w x 23’ x 1½" h
Depth of stage (plaster line to upstage wall): 40' x 1”
apron depth: 4'-2"
Stage width (wall to wall): 84'-7"
Grid height (deck to bottom of grid): 57'-3"
Stage height:
(above house floor at first row
of orchestra pit section) 2'-6"
Wing space (beyond proscenium edge)
Stage Right: 20'-11"
Stage left: 23'-8"
fly rail is operated from stage left deck.
hallway crossover: a 6'-0" wide hallway runs from stage
right left behind upstage wall. a single hinged door is located
upstage left and a double hinged door is located upstage right.
on stage crossover: an approximately 4'-0" wide on stage crossover,
with minimum obstruction, is possible between the last line set and upstage wall.
ConsTruCTIonSprung floor
black finished Masonite
august Wilson center Technical Specifications
Revised november 2015
page 12 of 27
back To Top
sTaGe pITThe orchestra pit platform is a scaffolding system composed of (11) platforms with wood decking,
aluminum frame and legs, which is used at orchestra level and has (28) removable seats.
This is the house default configuration.
The scaffolding system can be removed entirely from the orchestra pit, at which point
the pit can accommodate approximately (25) musicians at pit level.
Strike or restore of scaffolding system will require a minimum of 4 hours labor and
8 stage technicians. platforms must be restored during load out.
Dimensions at pit level: 44' l x 10'-6" w at center
8'-3" below stage deck level
pit Dimension at orchestra level: 41'-9" l x 8'-9" w at center
2'-6" below stage deck level
rIGGInG and sTaGInGequipped with a single purchased counterweight rigging system
(31) line sets with 56' long pipes
(1) line set with 60' long pipe
Maximum allowable distributed load per line set is 1,680 lb.
Maximum allowable point load per line set is 30 lb. per linear foot
line sets maximum out trim is 54'
locking rail is located on the stage left deck and loading rail is located on stage left fly gallery.
august Wilson center Technical Specifications
Revised november 2015
page 13 of 27
back To Top
sofT Goods InVenToryblack soft goods are 21 oz. velour.
all legs, borders and scrim have bottom pipe and are fire retardant.
all items are hanging at all times (See line set schedule).
(5) black velour borders (sewn flat with pipe pocket) 8' h x 56' w
(5) pair black velour legs (sewn flat with pipe pocket) 26' h x 10' w
(2) black velour travelers (80% fullness with bottom chain) 27'-6" h x 56' w
(1) white leno filled scrim cyclorama 29'-6" h x 56' w
(1) fire curtain on dedicated line set with various tripping mechanisms
(1) black scrim 28' h x 56' w
all scenery brought in by an event or production must be fire retardant to meet
pittsburgh fire Department regulations. flame certification must be submitted
to the production Management office (1) week prior to load in.
main drapeeggplant velour drape with fullness 27'-6" h x 62' w
Split at center Stage
Guillotine curtain manually operated from stage left deck fly rail
Maximum out trim of the main drape is approximately 2’-0” below the top of the proscenium.
august Wilson center Technical Specifications
Revised november 2015
page 14 of 27
back To Top
lIne seTs
distance from pipeline set plaster line house use Trim hight pounds Weight # length
pl 0
1 0'-3" Grand Valence 56'
2 0'-9" Grand Drape 896 32 60'
3 1'-3" 1 legs 60'
4 2'-3" 1st electric 56'
5 3'-9" 56'
6 5'-3" 56'
7 5'-9" 56'
8 7'-3" 2 border 21'-4" 88 5 56'
9 8'-7" 2 legs 66 3 56'
10 9'-11" 2nd electric 56'
11 11'-3" 56'
12 12'-7" 56'
13 13'-11" 56'
14 15'-3" 3 boarder 23' 102 5 56'
15 16'-7" 3 legs 66 3 56'
16 17'-11" 3rd electric 56'
17 19'-3" 56'
18 20'-7" Mid Traveler 308 14 56'
19 21'-11" 56'
20 23'-3" 4 border 23'-4" 102 5 56'
21 24'-7" 4 legs 66 3 56'
22 25'-11" 4th electric 56'
23 27'-3" 56'
24 28'-7" 5 border 88 4 56'
25 29'-3" 5 legs 66 3 56'
26 29'-11" black Scrim 56'
27 31'-3" 5th electric 56'
28 31'-11" US Traveler 56'
29 32'-7" 56'
30 33'-3" 56'
31 33'-11" cyc 56'
32 37'-3" Sl ladder 12'-3" 35'
33 37'-11" Sl ladder 12'-3" 35'
august Wilson center Technical Specifications
Revised november 2015
page 15 of 27
back To Top
eleCTrICs
dImmers & CIrCuITs426 eTc Sensor 2.4kw, at stage right mid-rail
6 eTc Sensor 6kw, at stage right mid-rail
lighting system is dimmer per circuit
circuits are distributed throughout stage, house and audience chamber
a portion of the dimmers are allocated to architectural and house lighting
(20) amp connectors are in 3-pin stage connectors
house lights are dimmable at light console
ConTorls(1) eTc ion 1500 lighting console
(1) Wireless Radio focus Remote
Remote Video interface
fader Wing – 2 x 20
(6) nodes available throughout the theatre to provide DMX in/out via eTc net3
lighting System operates on eTc net3
fIxTuresThe Theatre has a repertory lighting plot and any items that are moved or struck
must be restored as part of the load out. See light plot and line set schedule for details.
(5) eTc Source four 14º, 750w, 115v, hpl lamp
(24) eTc Source four 19º, 750w, 115v, hpl lamp
(50) eTc Source four 26º, 750w, 115v, hpl lamp
(20) eTc Source four 36º, 750w, 115v, hpl lamp
(2) eTc Source four 50º, 750w, 115v, hpl lamp
(10) paR64, Mfl or Wfl, 120v,1,000k lamp
(40) eTc Source four paR, 750w, 115v, hpl lamp
(12) Selecon hUi cyc 3-cell strip lights, 500w fcl lamp
(3) circuits – 1 gel/circuit
hardware and accessories
note: flown cyc lights only, no ground row
please call to advance current Rep plot status and inventory.
august Wilson center Technical Specifications
Revised november 2015
page 16 of 27
back To Top
aCCessorIes(30) eTc Source four type-a template holders
(1) eTc Source four iris kit
(10) 6 lb. – 10" diameter boom bases (floor mount)
folloW spoT booThlocation: above the balcony seating area at the
rear of the house in the catwalks level
Theatre is not equipped with follow Spots
available power: (2) 50 amp circuits
(2) 20 amp circuits
(2) 208v
lIGhT ladders(5) light ladders on (2) line sets
one on each side of the stage (4) rungs, 1-½" pipe, 9'-8" h x 3' w
Rated for: 217 lb. ladder
See light plot for detail.
Distance to center stage: 30'-0"
poWer dIsConneCTs(1) Theatrical lighting Mid-SR – deck 400 amp, 3 phase, 120/208v, cam lock
(1) Theatrical machinery: Mid-SR – deck 150 amp, 3 phase, 120/208v, cam lock
(1) sound (isolated ground): Mid-SR – deck 100 amp, 3 phase, 120/208v, cam lock
(1) sound company switch: control booth – 150 amp, 3 phase, 120/208v, cam lock
august Wilson center Technical Specifications
Revised november 2015
page 17 of 27
back To Top
august Wilson center Technical Specifications
Revised november 2015
page 18 of 27
back To Top
dImmer sChedule
line set sl Circuits rep
4 256 - 261 Sll4 262 - 267 1st elec9 244 - 249 1st elec
250 - 255 1st elec12 232 - 237 2nd elec12 238 - 243 2nd elec16 220 - 22516 226 - 23120 208 - 213 4th elec20 214 - 219 4th elec25 196 - 201 5th elec25 202 - 20730 184 - 18930 190 - 195 Sll
DSl on 328 - 333DSl off 334 - 339
USl 340 - 342
USl Wall 343 - 345USl Wall 346 - 348
Sl Grid 19 - 24 3rd elecSl Grid 25 - 30 3rd elecSl Grid 31 - 36 3rd elec
line set sr Circuits rep
4 100 - 105 Sll4 106 - 1119 112 - 117 2nd elec9 118 - 123 2nd elec12 124 - 129 2nd elec12 130 - 13516 136 - 14116 142 - 14720 148 - 153 4th elec20 154 - 159 4th elec25 160 - 165 5th elec25 166 - 171 5th elec30 172 - 17730 178 - 183 SRl
DSR on 361 - 366DSR off 355 - 360
USR 352 - 354
USR Wall 349 - 351
SR Grid 1 - 6 3rd elecSR Grid 7 - 12 3rd elecSR Grid 13 - 18 4th elec
cat #2 47 - 52cat #2 69 - 74
sound
Tie in to the house sound system is via XlR patch panels
located down stage right, down stage left, up stage right,
up stage left and in the orchestra pit. The cable path from the
stage to the in-house mix position is through a chase beneath
the orchestra level and is approximately 100'. access to the
basement chase is through a 6" diameter pipe located at the upstage right door.
ConTrol Yamaha M7cl-48 Digital Mixing console
location: control booth at rear center of orchestra level
booth has a sliding window
in-house mix position is in the center orchestra level in Row G.
consult productions Management office, in advance, if in-house mix position is required.
This involves coordination with box office ticket sales, and additional time and manpower.
Three seats will need removed: G107, G108, G109
processing & amplification
Yamaha DMe64n Digital Mixing engine
crown DSi 2000 amplifiers
speaker sysTemcenter cluster (3) eaW aX366
left cluster (2) eaW aX366 & (1) eaW aX122 (sub)
Right cluster (2) eaW aX366 & (1) eaW aX122 (sub)
Under balcony (6) Jbl control 26c
front fill (2) Renkus heinz pnX-212 sub
(2) Renkus heinz TRX – 151
audio playback
(1) Tascam X-1500 dual cD player
august Wilson center Technical Specifications
Revised november 2015
page 19 of 27
back To Top
InVenTory please call to advance
hearing assist systemequipped with listen infrared assistive listening system
CommunICaTIon four-channel clear-com MS440 – 4 – channel base station
program feed and paging system addresses all Dressing Rooms and Green Room
Communication equipmentclearcom MS440 – 4-channel base station
clearcom cc95 single ear headsets
clearcom RS 501 belt packs
hMe DX200 Wireless intercom
paging/program Distributed through out the dressing rooms
Guest Internet/Wi-fiThe facility has wireless for guest access. Registration works very much like most hotels –
a standard acceptable Use policy with sign up credentials is automatically sent when
guest attempt to sign on.
The pittsburgh Cultural Trust Guest Internet/Wi-fi Terms and Conditions of use agreement
please read the following information carefully before using this service. You may not use this service
without accepting and abiding by these Terms and conditions.
Welcome to the wireless high-speed internet access system (“internet/Wi-fi System”) at The pitts-
burgh cultural Trust. These “Terms and conditions of Use”. govern your responsibilities and our rights
and responsibilities relating to the use of the internet/Wi-fi system at The piTTSbURGh cUlTURal
TRUST.
acceptance of Terms and Conditions of usebY clickinG on “agree” on The inTeRneT/Wi-fi SYSTeM SiGn-Up paGe, YoU confiRM that:
1 YoU haVe ReaD, UnDeRSTooD anD aGRee To The TeRMS of ThiS aGReeMenT anD
2 if you Do noT aGRee to the terms of this agreement, you may not use the internet/Wi-fi System.
Your electronic acceptance of the agreement by clicking on “agree” on the sign-up page has the
same effect as if you had actually signed the agreement. The effective date of this agreement is the
date that you click on “agree”.
august Wilson center Technical Specifications
Revised november 2015
page 20 of 27
back To Top
description of Internet.Wi-fi system/service availabilityThe piTTSbURGh cUlTUal TRUST may provide access to the internet/Wi-fi System at locations (”en-
abled locations”) that have been equipped with wireless access points. access points or enabled loca-
tions may not be available in all areas of The piTTSbURGh cUlTURal TRUST, and may not always be
operational
Internet/Wi-fi system accessibilityThe internet/Wi-fi System a The piTTSbURGh cUlTURal TRUST is provide as a value added service to
the visitors, and business partners of The piTTSbURGh cUlTURal TRUST. Usage may be subject to
participation in a short online survey.
access to InternetThe piTTSbURGh cUlTUal TRUST does incorporate the use of web filters to restrict access to ques-
tionable content accessible through the internet. You acknowledge that if you access the internet you
may receive or be exposed to content, goods or services which you consider to be improper, inaccu-
rate, misleading, defamatory, obscene or otherwise offensive. You agree that The piTTSbURGh cUl-
TURal TRUST is not liable for any action or inaction with respect to any such content on the internet
accessible through the internet/Wi-fi System.
your responsibilitiesYou must (1) provide a valid email address. first name, last name, and Reason for accessing the in-
ternet/Wi-fi System, (2) understand that machine iD, and devise information will be collected upon
logging into the internet/Wi-fi System, (3) comply with local, state, federal and international laws and
regulations, including but not limited to copyright and intellectual property rights laws. You agree to be
responsible for and to bear all risk and consequences for (1) the accuracy, completeness, reliability
and/or usefulness of any content available through the internet/Wi-fi System and (2) all communica-
tions that you send or receive via the internet/Wi-fi System. The piTTSbURGh cUlTURal TRUST does
not undertake the security of any data you send through the internet/Wi-fi System and it is your re-
sponsibility to secure such data.
acceptable use policyall users of the internet/Wi-fi System must comply with the acceptable Use policy (aUp) contained in
this agreement. This aUp is intended to prevent unacceptable uses of the internet.
The piTTSbURGh cUlTURal TRUST reserves the right to actively monitor the use of the internet/Wi-fi
System under any circumstances. We do not exercise editorial control or review the content of any Web
site. electronic mail transmission, newsgroup or other material created or accessible over or through
the internet/Wi-fi System. however, we may remove, block, filter or restrict by any other means any
materials that, in our sole discretion, may be illegal, may subject The piTTSbURGh cUlTURal TRUST
to liability or harm or may violate this aUp. The piTTSbURGh cUlTURal TRUST may cooperate with
legal authorities and/or third parties in the investigation of any suspected or alleged crime or civil
wrong. Violation of this aUp may result in the suspension or termination of your access to the inter-
net/Wi-fi System.
The following constitute examples of violations of this aup.you agree to noT use Internet/Wi-fi system to:
1 Transmit any material (by uploading, posting, email or otherwise) that is unlawful, threatening,
abusive, harassing, tortious, defamatory, obscene, libelous, invasive of another’s privacy, hateful or
racially, ethnically or otherwise objectionable or harmful;
2 harm, or attempt to harm, minors or any person or entity in any way.
august Wilson center Technical Specifications
Revised november 2015
page 21 of 27
back To Top
3 impersonate any person or entity or falsely sate or otherwise misrepresent your affiliation with a
person or entity; forge headers or otherwise manipulate identities in order to disguise the origin of
any material transmitted through the internet/Wi-fi System;
4 Transmit any material (by uploading, posting, email or otherwise) that you do not have a right to
make available under any law or under contractual or fiduciary relationships (such as inside informa-
tion, proprietary and confidential information learned or disclosed as part of employment or other
confidential relationships or under not-disclosure agreements);
5 Transmit any material (by uploading, posting, email or otherwise) that infringes any patent, trade-
mark, trade secret, copyright or other proprietary or other rights of any party;
6 Transmit (by uploading, posting, email or otherwise) any unsolicited or unauthorized advertising,
promotional materials, “junk mail,” “spam,” “chain letters,” pyramid schemes” or any other form of
solicitation;
7 Transmit any material (by uploading, posting, email or otherwise) that contains software viruses or
any other computer code, files or programs designed to interrupt, destroy or limit the functionality
of any computer software or hardware or telecommunications equipment;
8 interfere with or disrupt the internet/Wi-fi System or servers or networks connected to the inter-
net/Wi-fi System, or disobey any requirements, procedures, policies or regulations of networks con-
nected to the internet/Wi-fi System;
9 intentionally or unintentionally violate any applicable local, state, national or international law, or
any regulations having the force of law;
10 “Stalk” or otherwise harass another; or collect or store, or attempt to collect or store, personal data
about third parties without their knowledge or consent;
11 Resell any portion of the internet/Wi-fi System or access to it without The piTTSbURGh cUlTURal
TRUST’s authorization;
12 Use the internet/Wi-fi System for high volume date transfers, especially sustained high volume
data transfers, hosting a web server, iRc server, or any other server;
13 Use the internet/Wi-fi System to stream bandwidth consuming audio and video services. examples
of such services include pandora Radio, XM Radio, Spotify and video services such as Slingbox,
netflix, iTunes.
You understand and agree that The piTTSbURGh cUlTURal TRUST may disclose your communica-
tions and activities using the internet/Wi-fi System in response to lawful requests by governmental
authorities, including patriot act requests, and judicial orders, and other third party requests.
The piTTSbURGh cUlTURal TRUST requests that anyone who believes that there is a violation of this
aUp direct the information to help@trustarts.org and include “Wifi” in the subject line. if available,
please provide the following information:
1 the ip address used to commit the alleged violation;
2 the date and time of the alleged violation, including the time zone;
3 evidence of the alleged violation, and
4 your contact details including full name, email address and telephone number.
When reporting an issue regarding unsolicited email please provide a copy of the email messages with
full headers which typically provides all of the above data. other situations will require different meth-
ods of providing the necessary information.
august Wilson center Technical Specifications
Revised november 2015
page 22 of 27
back To Top
TerminationYou agree that The piTTSbURGh cUlTURal TRUST may terminate this agreement and cancel your ac-
cess to the internet/Wi-fi System at any time, without notice and for any reason including, but not lim-
ited to , violation of any of the terms and conditions of this agreement, security or safety reasons,
and/or using the internet/Wi-fi System to perform any illegal activity. You further agree that in the
event of termination for any reason. The piTTSbURGh cUlTURal TRUST will have no liability to you or
any third party.
notice of problems or Complaintsif you experience a problem accessing or using the internet/Wi-fi System, report the problem by call-
ing 412-325-help or by emailing help@trustarts.org and including “Wifi” in the subject line.
modificationsThe piTTSbURGh cUlTURal TRUST may, at its sole discretion, modify the terms and conditions of this
agreement, including the aUp, at any time. Such modifications shall be binding and effective upon post-
ing on the internet/Wi-fi System ‘internet access Signup” page. You agree to periodically review the
‘internet access Signup’ page to maintain awareness of any modifications. by continuing to use the in-
ternet/Wi-fi System after such postings, you accept and agree to any and all such modifications.
IndemnificationYou shall defend, indemnify and hold The piTTSbURGh cUlTURal TRUST and its corporate affiliates
and their respective officers, directors, stockholders, employees, contractors, agents, successors and
assigns harmless from and against, and shall promptly reimburse them for, any and all losses, claims,
damages, settlements, costs and liabilities of any natural whatsoever (including reasonable attorneys’
fees) to which any of them may become subject arising out of , based upon, as a result of, or in any
way connected with, your use of the internet/Wi-fi System or any breach of this agreement.
no WarrantyThe inTeRneT/Wi-fi SYSTeM iS pRoViDeD on an “aS iS” anD “aS aVailable” baSiS, WiThoUT
WaRRanTieS of anY kinD. The piTTSbURGh cUlTURal TRUST DoeS noT WaRRanT ThaT The
SeRViceS Will be fUncTional, UninTeRRUpTeD, eRRoR-fRee, oR fRee of ViRUSeS oR oTheR
haRMfUl coMponenTS. The piTTSbURGh cUlTURal TRUST MakeS no eXpReSS WaRRanTieS anD
cUSToMeR WaiVeS all iMplieD WaRRanTieS inclUDinG, bUT noT liMiTeD To WaRRanTieS of
TiTle, non infRinGeMenT, MeRchanTabiliTY, anD fiTneSS foR a paRTicUlaR pURpoSe ReGaRD-
inG anY MeRchanDiSe, infoRMaTion oR SeRVice pRoViDeD ThRoUGh The piTTSbURGh cUl-
TURal TRUST oR The inTeRneT GeneRallY. cUSToMeR eXpReSSlY acknoWleDGeS ThaT TheRe
aRe, anD aSSUMeS all ReSponSibiliTY RelaTeD To, The SecURiTY, pRiVacY anD confiDenTial-
iTY RiSkS inheRenT in WiReleSS coMMUnicaTionS anD TechnoloGY anD The piTTSbURGh
cUlTURal TRUST DoeS noT Make anY aSSURanceS oR WaRRanTieS RelaTinG To SUch RiSkS.
noW aDVice oR infoRMaTion GiVen bY The piTTSbURGh cUlTUal TRUST oR iTS RepReSenTa-
TiVeS Shall cReaTe a WaRRanTY.
limitation of liabilityThe piTTSbURGh cUlTURal TRUST, iTS eMploYeeS, aGenTS, VenDoRS, anD licenSoRS aRe noT
liable foR anY coSTS oR DaMaGeS aRiSinG, eiTheR DiRecTlY oR inDiRecTlY, fRoM YoUR USe
of The inTeRneT/Wi-fi SYSTeM oR The inTeRneT, SpecificallY inclUDinG anY DiRecT , inDi-
RecT inciDenTal, eXeMplaRY, MUlTiple,, Special, pUniTiVe oR conSeqUenTial DaMaGeS.
august Wilson center Technical Specifications
Revised november 2015
page 23 of 27
back To Top
radio frequency Coordination policyuse of radio frequency (rf) equipment by Visiting productions and prior frequency Coordination
1 in an effort to ensure all events and users are able to avoid radio frequency (Rf) interference with
production and venue related Rf equipment, it is required without exception that all Rf transmis-
sion equipment to be brought into or onto venue property by any visiting production, except that
listed in the “Rf Transmission equipment exception list”, be coordinated with the benedum center
audio Department at least (1) week prior to load in.
2 all visiting production’s Rf transmission equipment shall comply with all pertinent federal communi-
cations commission (fcc) rules and regulations in effect at the time of load in and for the duration
of the production. The benedum center reserves the right to examine and test the visiting produc-
tion’s Rf transmission equipment at any time it is scheduled to be used on venue property to insure
conformity with manufacturer’s performance specifications, compliance with fcc technical require-
ments, to determine interference potential, and/or to determine suspect interference.
3 Under no circumstances will the benedum center permit, authorize or otherwise tolerate the opera-
tion of any transmission equipment which has as its primary purpose to jam or otherwise restrict the
operation of cellular/pcS or pager services in the frequency range of 698Mhz - 2000Mhz (2Ghz).
4 failure to coordinate the visiting production’s Rf transmission equipment with the venue prior to load
in may result in the delay of, or forbiddance to use the Rf equipment. The benedum center reserves
the right to take such action as it believes reasonably necessary in order to prevent operation of said
equipment until the coordination and/or interference issues can be resolved, or to secure the
transmission equipment until it can be removed from the venue.
5 for the purposes of prior coordination, the visiting production shall provide the following detailed
Rf transmission equipment information to the benedum center audio Department at least (1) week
prior to load in:
a) contact name and mobile telephone number and/or e-mail address of individual responsible
for visiting production’s Rf transmission equipment
b) The manufacturer, model, specific frequency bandsplit(s) or pre-programmed
frequencies (if applicable) of each piece of Rf transmission equipment to be operated
on venue property by the production
c) quantities of each item in paragraph 4a
d) if Rf transmission equipment is capable of variable Rf power output, proposed
power level for use on venue property must be indicated for each piece of Rf
transmission equipment
e) posed frequencies for use as a result of any pre-determined frequency band plan
Radio Frequency Coordination Policy (continued)
6 partial list of Rf transmission equipment subject to prior coordination:
- Two-way radios operating in any frequency range, including 800Mhz eSMR (nextel) and
conventional trunking radios
- Wireless microphones operating in any frequency range
- Wireless in-ear-monitors (ieM) operating in any frequency range
- Wireless intercom operating in any frequency range
- Wireless cueing and/or interruptible foldback (ifb) operating in any frequency range
- assisted listening systems operating in any frequency range
- Wireless video systems operating in any frequency range
- Wireless programmable logic controllers (plc) operating in any frequency range
august Wilson center Technical Specifications
Revised november 2015
page 24 of 27
back To Top
- Wireless data modems operating in any frequency range
- Wireless automation control operating in any frequency range
- Wireless lighting and DMX control operating in any frequency range
- Wireless control of any type operating in any frequency range
- Wireless access point/router (Wap / Wi-fi) operating in any frequency range
- bi-directional amplifiers/systems for eSMR (nextel)/cellular/pcS services
- Microwave ovens
- any Rf device operating in any frequency range not listed in “Rf Transmission
equipment exception list”
7 Any visiting production Rf transmission equipment operating in the following frequency ranges are
subject to prior coordination:
- 100khz - 806Mhz
- 896Mhz - 901Mhz
- 902Mhz - 930Mhz
- 935Mhz - 940Mhz
- 944Mhz - 952Mhz
- 2400Mhz - 2485Mhz (2.4Ghz - 2.485Ghz)
- 5030Mhz - 5350Mhz (5.03Ghz - 5.35Ghz)
- 5470Mhz - 5830Mhz (5.47Ghz - 5.83Ghz)
8 Rf Transmission equipment exception list:
- cellular (700/800/850Mhz) and pcS (1700/1800/1900/2100Mhz) [subscriber] phones
- Wi-fi wireless client devices, such as computers and pDas
9 a template can be provided upon request to submit visiting production Rf transmission equipment to
the benedum center audio Department. information sheets already composed by visiting production
may be submitted so long as it contains the complete information as detailed in paragraph 5.
10 Rf equipment information, as well as any inquiry regarding this policy or the information
to be provided must be submitted to the benedum center audio Department at:
evans@pgharts.org
faX: 412-456-2647 (attention chris evans)
august Wilson center Technical Specifications
Revised november 2015
page 25 of 27
back To Top
VIdeo
Closed CIrCuIT VIdeo color video cameras are located in the orchestra pit for conductor view and
on balcony rail for stage view. color monitors are located in the Donor lounge,
Dressing Room 153 and Green Room 157.
pyroTeChnICs & fIre
all facilities must apply for live flame (any open flame in a public space) or pyrotechnic permits
with the city of pittsburgh fire bureau. please advance with the production Department.
props
(50) Music Stands
(50) Music stand lights
(50) Wenger nola padded orchestra chairs
(2) podiums
Wardrobe / laundry
Wardrobeaacc does not have a designated wardrobe room
all wardrobe equipment is stored in dressing rooms
laundryaacc does not provide linen service.
Washers and dryers are stacked front loading and located in closets of dressing rooms
158 and 160
equipment: (2) front-loading washers – lG Direct Drive WM2010cW
(2) front –loading dryers – lG Dle1310W
Steamer
iron
ironing board
Rolling wardrobe racks
august Wilson center Technical Specifications
Revised november 2015
page 26 of 27
back To Top
dressInG rooms
all dressing rooms are at stage level and adjacent
to upstage doors
all dressing rooms are equipped with make-up mirrors,
electrical outlets, stackable chairs, bathroom and shower.
all dressing rooms and Green Room are aDa accessible
Dressing Room 153: 1-3 person room with 42" monitor and two (2) club chairs
Dressing Room 155: 2-7 person room
Dressing Room 158: 7 person room
Dressing Room 160: 7 person room
Green room
Room 157 located at stage level and adjacent to
upstage doors
equipment: (1) refrigerator
(1) microwave
(1) 42" video monitor
(2) club chairs
(1) sofa
sTaGe rIsers / personal lIfTs
(8) 4' x 8' Wenger risers (each with 2 sets of legs – 16" and 24")
(1) JlG 30aM personnel liftpersonnel lift must be operated with outriggers installed and basket must be lowered before the lift is moved.
personnel life may be operated by house staff only.
august Wilson center Technical Specifications
Revised november 2015
page 27 of 27
back To Top