TRANSCRIPT

AccuLoad III Blending

Sequential Blending

Sequential Blending

• Blending of More Than One Product Into a Truck Through the Sequencing of Product-Specific Block Valves One Product at a Time Through One Meter With Up to 50 Recipes Available.

• The ratio of varying products is designated in the recipe as a percentage of the total preset.

• These percentages must total 100%.

• AccuLoad automatically calculates the actual volumes of each product to be delivered.

• The order of product delivery must be included in the recipe definition.

Sequential Blending

Block Valves

Control Valve

Product Pumps

MeterStrainerProduct 4

Product 2

Product 3

Product 1

Sequential Loading ProfileF

low

Rate

Low Flow Start Volume

Product “A” Product “B”

First Trip First Trip

Gallons to Be Delivered (50% Product A, 50% Product B)

2nd Trip 2nd Trip

Sequential Dynamic Display

“Blend” dynamic displays show all data associated with a specific

sequential blending transaction.

CBR = Current Blend Ratio

Flow = Current Flow Rate Amount = Batch Amount Delivered

Click Display to View Sequential Blend Dynamic Display

Ratio Blending

Ratio Blending

• Blending More Than One Product Into a Truck Simultaneously Through Dedicated Product Lines Each Having Its Own Meter and Control Valve Co-Mingling in a Common Header

• The ratio of the component products is designated in the recipe as a percentage of the total preset.

• These percentages must total 100%.

• The AccuLoad III automatically calculates the actual volumes of each product to be delivered.

• Flow rates are adjusted for optimal blend accuracy while conforming to the programmed system flow profile using Smith's exclusive control algorithm.

Ratio Blending

Meters Control ValvesStrainers

Product 3

Product 2

Product 4

Product 1

Pumps

2,000 130 0

Ratio Loading Profile

Gallons to Be Delivered

System High Flow 800 GPM Low Flow Start Rate 300 GPM

1,000

800

600

400

200

0Ethanol (10%)

Regular (90%)

Blended

Flow Rate (GPM)

Ratio Dynamic Display

Click Display to View Ratio Blending Dynamic Display

“Ratio Blend” data dynamic displays show all data associated with a specific ratio blending transaction.

CBR = Current Blend Ratio

DBR = Desired Blend Ratio

DRate = Desired Flow Rate

TOL = Flow Tolerance

CRate = Current Flow Rate

Gallons to Be Delivered2,000 0

1,000

800

600

400

200

0

Flow Rate (GPM)

Blend (AFO)Regular AFO Engaged

Premium

Blend

Regular (70%)

Premium (30%)

Automatic Flow Optimization on Blend

Ratio Clean Line

2,000 100 0Clean Line

Product

Regular 90%

Blended

Regular (90%)

Blended

Hybrid Blending

Hybrid Blending

• Hybrid Blending is a Combination of Sequential Blending and Ratio Blending.

• Suited for Applications Such as Ethanol Blending or Bio-Diesel Blending.

• The Sequential Products Flow One at a Time.

• Ratio Products Flow Simultaneously with Each of the Sequential Products.

• Ratio Product(s) can be Plumbed Either Upstream or Downstream of the Sequential Product Meter.

• Up to 5 Ratio Product Meters on One Arm

Hybrid Blending (Downstream)

Product 1

Product 2

Product 3

Product 4

Load Arm

BV

BV

Mtr #1

Mtr #2

CV

CV

Sequential Products

Ratio Product

BV

BV

Hybrid Blending (Upstream)

Product 1

Product 2

Product 3

Product 4

Load Arm

Mtr # 1

Mtr# 2

CV

CV

Sequential Products

Ratio Products

BV

BV

BV

Hybrid Blending Directories

Ratio Meter

Sequential

Meter

Ratio Product

Sequential

Products

Ratio Meter

Ratio Product

Hybrid Blending Directories

Ratio Meter

Sequential

Meter

Ratio Product

Sequential

Products

Hybrid Flow ProfileF

low

Rate

Low Flow Start Volume

Product 2 Product 3

1st Trip 1st Trip

Gallons to Be Delivered (10% Product 1, 45% Product 2, 45% Product 3 )

2nd Trip 2nd Trip

Product 1 Product 1

1st Trip 1st Trip

• Each Ratio Product for Hybrid Arms Require a Control Valve.

• The Sequential Meter Requires 1 Control Valve.

• Each Sequential Product Requires a Block Valve if Multiple Sequential Products are Programmed.

Hybrid Programming

Wildstream Blending

Wildstream Blending

• Provides Continuous In-Line Blending of two or More Products.

• Load Arm is Configured as Hybrid.

• Meters can be Plumbed Upstream or Downstream

• Programmable Unlimited Preset Parameter.

• Wildstream can be Controlled or Uncontrolled.

• Up to Three Loading Arms With two Products Each

Wildstream Configuration

• The First Meter(s) Configured

are the Controlled Products.

• Number of Controlled Products

is Determined by the Number

of Ratio Products

Programmed.

• The Last Meter Configured is

the Wildstream Product

Upstream Plumbed

• Controlled Product

Plumbed Upstream of the

Wildstream Product.

• Uncontrolled Wildstream

Product.

Two Controlled Products

• On the Fly Blend Percent and

Meter Change

• Uncontrolled Wildstream

Product.

• Recipe can be changed via

Communications or Recipe

Select Input

Three Wildstream Arms

• Three Uncontrolled Wildstream

Products.

• Three controlled Products

Unlimited Preset

• Arm High Flow Rate not Required for Unlimited Preset.

• Arm Low Flow Start Rate is not Used for Wildstream.

• If High Flow Rate is Programmed, Excess High Flow Rate Alarm can be Used.

• Controlled Product Flow Rate Based on Wildstream Flow rate.

• AccuLoad Adjusts the Controlled Product Flow Rate to Adjust Blend Percentage in Recipe.

• Timed Blend Algorithm is automatically used When Set to Unlimited Preset.

• Ratio Adjust Factor Algorithm will not be used.

Controlled Wildstream

• Desired Flow Rates are Based on Programmed High and Low Flow Rates.

• Arm High Flow Rate is used if all Meters are Controlled.

• Low Flow Start Rate is Used if all Meters are Controlled.

• Blend Adjustments are Made After Low Flow Start Amount.

• AccuLoad Adjusts Both Controlled Product Flow Rates to Adjust Blend Percentage of Recipe.