AS1684 RevisionResidential Timber Framed
Construction Standard 2006 Edition
Reason for Revision
A requirement by Standards Australia to review BCA primary reference standards every 5 years.
Reason for Revision
Its been 6 years since the last revisionThis standard was first published in 1999
With amendments dated:1. April 20002. October 20003. May 20014. May 2002
2
Revision Objectives
Address issues and practices of some state building industry interests to reflect:
State needs&
Construction practices
Revision Objectives
Include:Editorial amendments
&Technical changes
Revision Objectives
Improve deemed to satisfy (DTS) usage&
Provide economical DTS details
3
Changes to Section1Scope and General
Changes to Section1Scope and General
Clause 1.2 (1999 Version)“Application”
has been deleted
this clause used to introduce the Standard in January 2000 (no longer necessary)
4
Changes to Section1Scope and General
Clause 1.3 (1999 Version)“Use of alternative materials or methods”
has been deletedthis is the role of the BCA (provide DTS solutions) however does not preclude the use of alternative systems
Changes to Section1Scope and General
Clause 1.4 (1999 Version)“Companion Documents”
moved to Clause 1.2AS1684.1 Design criteria (unchanged)AS1684.3 Cyclonic wind areasAS1684.4 Simplified – Non-cyclonic areas
AS1684 Parts 3 & 4
The changes in Part 2 have been mirrored in Parts 3 & 4
5
Changes to Section1Scope and General
Clause 1.5 (1999 Version)“Referenced Documents”
has been deleted
Replaced with:
Changes to Section1Scope and General
Clause 1.3 (2006 Version)“Normative References”
a new clauselists 36 other Standards & the BCAas indispensable documentsnominates Appendix A as a list of “informative” related documents (page 218)
Explanation from the Preface
“Normative”an integral part of the Standard
“Informative”for information and guidance only
6
Changes to Section1Scope and General
1.16 Interpolation1.18 Interpolation
1.15 Considerations for Design using this Standard
1.17 Guidelines for Design using this Standard
1.14 Alternative Timber Dimensions1.16 Alternative Timber Dimensions
1.13 Size Tolerances1.15 Size Tolerances
1.12 Engineered Timber Products1.14 Engineered Timber Products
1.11 Stress Grades1.13 Stress Grades
1.10 Bearing1.12 Bearing
1.9 Dimensions1.11 Dimensions
1.8 Durability1.10 Durability
1.7 Load Paths Offsets and Cantilevers1.9 Load Paths Offsets and Cantilevers
1.6 Forces on Buildings1.8 Forces on Buildings
1.5 Design Criteria1.7 Design Criteria
1.4 Limitations1.6 Limitations
AS1684.2 2006AS1684.2 1999
Changes to Section1Scope and General
Clause 1.8 (2006 Version)“Durability”
a technical changeAbove-ground durability classes (now nominated)Reference to AS1720 parts 1 & 2 deletedNew reference to AS5604
(more detail in Appendix C)
Changes to Section1Scope and General
Clause 1.11 (2006 Version)“Stress Grades”
a technical change (contained within the notes to Table 1.2)
span tables from the standard can now be used for F8 & F11 unseasoned softwood F8 & F11 unseasoned hardwood tables are recommended for use (no new table)
7
Changes to Section1Scope and General
Clause 1.15 (2006 Version)“Considerations for Design using this Standard”
a name change onlyhowever nominated Clause 1.6 has been changed to 1.4 to line up with the overall renumbering of the clauses
Section1Scope and General
Clause 1.15 “Considerations for Design using this Standard”Nominates procedures to be adopted
must first determineDesign gust wind speed
&Corresponding wind classification
Section1Scope and General
Clause 1.15 “Considerations for Design using this Standard”
basic considerationwind classification is the primary reference used throughout this Standard recommends flow chart in Figure 1.7 as guidance for design procedures (page 18)
8
Changes to Section 5 Flooring and Decking
Clause 5.7 (1999 Version)
Decking has been removed
Table 5.3 upgraded
Changes to Section 5 Flooring and Decking
Clause 5.7 (2006 Version)refers only to maximum spacing of supports for T & G and sheet flooring
Table 5.3 – Strip Flooringall hardwoods considered on density and grading characteristics only, as per AS2796Softwoods (excluding cypress) are noted as per the detail of AS4785.1
9
Changes to Section 5 Flooring and Decking
Clause 5.8 (2006 Version)a new clause
Decking – deals only with the spacing of floor joists for timber decking
Table 5.4, moved from Clause 5.7Table 5.5, Decking Board Fixing Requirements has been added
Changes to Section 5 Flooring and Decking
Clause 5.8 (2006 Version)
Table 5.5, Decking Board Fixing Requirements
Specifies hot-dip galv or stainless steel2 nails per board crossingDifferent thicknesses for machine or hand-driven nails
10
Changes to Section 6 Wall Framing
Clause 6.2 (2006 Version)
Section 6.2.3 Openingsspecifies that jack studs must be the same orientation as the common studsallows the use of nail lamination in jack studs
Changes to Section 6 Wall Framing
Clause 6.2 (2006 Version) Section 6.2.3 Openings– Figure 6.9 Openings, Detail (a)
span has been increased from 900 mm to 1200 mmtitle has been amended to include (Non-loadingbearing walls)
11
Changes to Section 6 Wall Framing
Clause 6.3 (2006 Version) Section 6.3.8 Posts supporting roof and/ or floor loadsAn allowance has been made for the use of undersized seasoned posts
New paragraph at bottom of page 79
Changes to Section 6 Wall Framing
Clause 6.3 (2006 Version) Section 6.3.8 Posts supporting roof and/ or floor loads
Industry normal is up to 3mm under size i.e. 90 X 90 are normally 88 x 88mmCalculate roof and/or floor area to be supported 10% bigger, then use nominal seasoned size from Span Table 53
Change to Section 7 Roof Framing
Clause 7.2 (2006 Version)Section 7.2.10.4 Support of underpurlins
This section has been completely rewrittenGreater clarification is given to underpurlins that support valley or hip rafters
12
Change to Section 7 Roof Framing
Clause 7.2 (2006 Version)Section 7.2.10.4 Support of underpurlinsThere are 2 new subsections
(a) Underpurlins supporting a hip or valley rafter
Change to Section 7 Roof Framing
Clause 7.2 (2006 Version)Section 7.2.10.4 Support of underpurlinsThere are 2 new subsections
(a) Underpurlins supporting a hip or valley rafter(b) Underpurlins supported by a hip or valley rafter
13
Change to Section 7 Roof Framing
Clause 7.2 (2006 Version)Section 7.2.10.4 Support of underpurlinsThere are 2 new subsections
(a) Underpurlins supporting a hip or valley rafter(b) Underpurlins supported by a hip or valley rafterFigure 7.7 has been upgraded
14
Changes to Section 8 Racking and Shear Forces
(Bracing)
Clause 8.1 (2006 Version)8.1 General
the inclusion of the words “shall be” preceding “distributed evenly throughout” in the 2nd paragraph
Changes to Section 8 Racking and Shear Forces
(Bracing)
Clause 8.1 (2006 Version)8.1 General
“even distribution” now becomes a requirement rather than a recommendationstill no guidance on what “even distribution” means.
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing
extra fixing requirements included in some of the detailsexample detail (b)
15
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing
extra fixing requirements included in some of the detailsexample detail (b)example detail (d)
16
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing/Errors
(advised by TDA Engineer Andrew Dunn)detail (d)
Net sectional area of alternative metal strap should be 24 mm² not 15 mm² as shownFixing of bottom plate requires specific fixing from Clause 8.3.6.10 – not nominal as shown
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing
additional details and Bracing types added to Hardboard
17
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing Detail (l) Hardboard Type A
Minimum thickness, 4.8 mm specifiedSpacing and length of nail fixing has been alteredFixing of bottom plate to floor frame or slab has been reduced to nominal fixing only
18
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing Detail (m) Hardboard Types B & C
Type C is new, a 9kN/m unitMinimum thickness, 4.8 mm specifiedSpacing of nail fixing has been alteredSpecific fixing details of bottom plate to floor frame or slab have been included for both Types B & C
19
20
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing Detail (n) Hardboard Types D & E
Type D is new Short Panel, 3.4kN/m unitMinimum thickness, 4.8 mm specifiedSpacing and type of fixings specifiedNominal fixing of bottom plate to floor frame or slab for Type D only
21
22
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing Detail (n) Hardboard Types D & E
Type E is new Short Panel, 6.0kN/m unitMinimum thickness, 4.8 mm specifiedSpacing and type of fixings specifiedSpecific fixing of bottom plate to floor frame or slab is required i.e. M12 rods each end
23
Changes to Section 8 Racking and Shear Forces
(Bracing)
Table 8.18 (2006 Version)Structural Wall Bracing All Details Hardboard Types A B C D & E
A new note to all details, L M & N, which specifies that at least one side of the bracing wall shall be lined with gypsum plaster board or equivalent
24
Changes to Section 9 Fixings and Tie-Down Design
Clause 9.2 (2006 Version) General Connection Requirements Section 9.2.2 Corrosion protection and steel grade – has been revised
minimum corrosion protection for strap or similar connections – shall be Z 275Minimum thickness of strap – shall be 0.8 mmMinimum steel grade for strap or similar connections – shall be G 300
Changes to Section 9 Fixings and Tie-Down Design
Table 9.15 (2006 Version) Joint Groups
Item 6 – Elsewhere has been clarifiedNow reads –Douglas fir (Oregon) from elsewhereunseasoned J5seasoned JD5
25
Changes to Appendices
There are 9 separate appendices
Changes to Appendix A Informative and Related Documents
Renamed – formerly “List of Referenced and Related Documents”Reclassified as “Informative”
The “referenced Documents” have been placed into the body of the standard at Section 1 Clause 1.3 Normative References
26
Changes to Appendix B Typical Construction Mass
Renamed – formerly “Mass of Roof”
Table B1.2 renamed as “Guide for Determination of Typical Building Construction Mass”No real change, only slight restructure of the table
Changes to Appendix C Durability
C 1 Durability – now includes the new above – ground durability recommendations
Figure C 1 has been updated to include above –ground durability selections
27
Changes to Appendix C Durability
Table C 1 has been updated to include more detailed specifications, the new headings are:
ExposureSpecific service conditionsBiological hazardTypical use
Changes to Appendix H Timber Species and Properties
H 2.10 (2006 Version) : now reads as –Natural durability class of heartwood
upgraded to include the new above – ground durability recommendationsTable H2 has been added to define the probable life expectancy of above - ground
28
Extract from Table H1
Changes to Appendix H Timber Species and Properties
H 2.11 (2006 Version) : now reads as –Lyctid susceptibility of sapwood
RS – Rarely susceptible (has been deleted) New note has been added to explain the case of Alpine Ash and to confirm if origin unknown it must be assumed to be susceptible
29
Extract from Table H1
Timber Solution SoftwareThe computer program used to derive
the AS1684 span tables is now: “free to download”
www.timber.org.au or www.timber.net.au
AS1684 RevisionResidential Timber Framed
Construction Standard 2006 Edition