Assorted DrawingsBy: Brian Stillman

stillmanbd@aol.com

801-716-0705

Residential & Commercial As Built Measuring & Drafting

New Construction Drafting/Design

764 E.

N

12" below sill for drainage

768 E.

Wate

r

2'8/3'0 Casement

Concrete

Concrete

Concrete

Concrete

Con

cre

te

AsphaltAsphalt

Con

cre

te

20

0 S

o.

167'-112"167'-112"167'-1

12

"167'-112"

1 1/2" Minus

Telephone Pole

Excavate New Window Sill12" below sill for drainageExcavate New Window Sill

New Window Well's w/steps to accomodate fully opened casement window's

12" below sill for drainage

2'8 Casement

Excavate New Window Sill

Window Well to accomodate fully open window

Po

wer

Up

Down

SplitEntry

2'8/3'0 Casement

2'6 x 1'6

Ga

s V

alv

e

2'0

x 1

6"

2'6

x 1

'6

Laundry

2'6 x 1'62'6 x 1'6

Sill 63"Sill 63"Sill 63'

Sill 6

3"

Sill 6

1"

2'6 x 1'6

Sill 61"

2'0 x 1'6

Sill 66"

Do

wn

Po

wer

Up Split

Entry

Gas

Elec. Mtr. Up

Up

N

3'0 x 6'8

PlanterPlanter

Con

cre

te

20

0 S

o.

1 1/2" Minus

171'-712"171'-712"171'-7

12

"171'-712"

46'-578

"46'-578

"46'-578

"46'-578

"

43'-314"43'-314"43'-3

14"43'-3

14

"

N

Scale: 1/8" = 1'0"

Scale: 1/8" = 1'0"

Wate

r

Landing

20'20'

24'-112

"24'-112"

1 Hour Fire Wall 1/2" Gypsum over 2 x 4 framing

12'-4"12'-4"

37'-314"

4'-238

"

41

'-2

1 4"

24'-418

"

9'-2 14 "

3'-9 14 "

2'-858

"

5'-6 58 "

Trench Form

6'-3

1 4"

2"

9"

1'-01/2"

Scale: 1:6

R 3"

R 1/2"

R 3"

Trench Form roll formed out of 10 guagesheet mat'l. in 10' lengths.

Saw cut perimeter

Saw cut perimeter

1-1

/2"

R 1/2"

Box Outlet

U Channel (typical)

Mill U Channel (3 @ 4.1) - 3" wide x 1.41 leg, .170 web & .273 flangeCross brace every 24" as depicted

3 1/2" holes in cross braces 4" apart.

Demo Concrete & Remove Earth To Accomodate6" Lining Of Magneco-Metrel "acid proof" Refractory - METPUMP AP

Truck Load - Out

Pad

Truck Load - OutPump

METPUMP AP

Scale: 1:6

R 3"

R 1/2"R 1/2"

R 3"

(To be pumped in)

Saw Cut Line

R 1/2"R 1/2"

Cut 10' form sections to match angles in trench

Field weld trench form & modify to fit

Anchor U Channel cross bracing into existing pavement

Exstg. Pavement

6"

6"

(welding joints as necessary)

as required.

Plan View

Cross brace every 24" as depicted.

3 1/2" holes in cross braces 4" apart.

2'

Scale: 1:3

1'-4

1/2

2'

10'

1'-9" 2' 2' 2' 2'

Scale: 1:3

R 3"

R 1/2"R 1/2"

R 3"

Trench Form

R 1/2"R 1/2"

1'-4 1/2"U Channel

2' 2'

1-1

1/2

"

9"

2"

1'-0 1/2"

Weld Weld

Trench Form roll formed out of 10 guage sheet mat'l. in 10' lengths

Cross Section

U Channel

U C

ha

nnel

U C

ha

nnel

U C

ha

nnel

U C

ha

nnel

U C

ha

nnel

U C

ha

nnel

N

(2)

ST

OR

Y B

UIL

DIN

GT

OT

AL G

SF

: 3,1

78 S

.F.

FO

OT

PR

INT

: 1,5

89 S

.F.

PP

FH

property line

Easement

Dim

ensio

ns w

ill c

hange

Loca

tion is a

ppro

xim

ate

HUNTSMANPARCEL 1

Fern

Avenue

RO

W E

asem

ent

Neig

hboring

2-P

lex

Neig

hboring

Off

ice B

uild

ing

Porch Area

6'

Driveway

8' R

RO

W E

asem

ent

4'-6"

pro

pe

rty lin

e

Drive

way

100

300 West

HUNTSMAN

PP

PARCEL 2

Of Exstg. Apts.

27'-9" 3'

Sid

ew

alk

No. Bldg. Edge

14'

Sta

ll 3

Option 145°

8'-3"

17'-6"

22'-6

"

9'

17'

2'-4"7'

7'-412"

Ramp

8' R Ram

p

102.33

7'

Exis

tin

g D

rive

wa

y

HUNTSMAN

(2)

ST

OR

Y B

UIL

DIN

GT

OT

AL

GS

F:

3,1

78

S.F

.F

OO

TP

RIN

T:

1,5

89

S.F

.

PP

FH

property line

Dim

en

sio

ns w

ill c

ha

ng

e

Lo

ca

tio

n is a

pp

roxim

ate

PARCEL 2

HUNTSMANPARCEL 1

Fe

rn A

ve

nu

e

Ne

igh

bo

rin

g 2

-Ple

x

Ne

igh

bo

rin

g O

ffic

e B

uild

ing

Porch Area

Of Exstg. Apts.

27'-9" 3'

Sid

ew

alk

No. Bldg. Edge

Drive

wa

y

14'

Ra

mp

8' R

100

2'-4"7'

7'-412"

Ramp

300 West

N

14'-9"

PP

Option 2

8'-3"

45°

17'-2

1 2"

Sta

ll 3

Sta

ll 4

9'

17'

22'-6

"

102.33

Basic Road Profile with varying width's

AVENUES ADDITION

2 x 4 PT/Rdwd. Sill PL over foam sill

1/2" x 7" JBolt w/Code Washer spcd. @ 4' O.C.

1/2" rebar w/bars & corners overlapping 18"

1/2" "L" Bar @ 24" O.C.

2 ea ftng. #4 rebar w/18" overlap

5 1/2" Fndtn. Wall & Ftng.

(No closer to an end of board - 2 3/4")

3,000 p.s.i. for ea.

3'-3

1 2"

91 4"

1'-6"

using 3" x 3" x 3/16" plate washer. R403.16 & R602.11

3 1/2" 3500 psi concrete floor slab

4" - 1" minus compacted washed rock

5 1/2" Fndtn. Wall, Ftng. & Slab

Match exstg. top of slab @ doorway

U210 Hanger

HPAHD 16 @ ea. Corner So. Wall

#4 Bar Dowell

(At Walk Through)

West Elevation

HPAHD 16 @ ea. Corner So. WallHPAHD 16 @ ea. Corner So. Wall

U210 Hanger2 x 10 2 x 10

2 x 4 DF 16" O.C.

2 x10

2 x10 2 x10

2 x10

Frame Window's to R.O. Frame Window's to R.O.

East Elevation

12

5

12

5

12

5

12

5

2 x 6 2 x 6

2 x 4 DF 16" O.C.

8'-0"

8'-0"

3' Steel Strap @ ea.sideof main floor windows

3' Steel Strap @ ea.sideof main floor windows

Main Floor Framing

4'

10

'-6

"

26'

1'-4"

6'

3'

South Elevation

2 x 10

2 x 10 2 x10 2 x10 2 x 10

Main Level

Fridge39"

Washer

Dryer

D/W

5'-512"

4'-512"

13'-812"

10'-6"

3'

do

wn

2'-8"

3'-1"

7'-3"

2'-8

"

4'-8"

17'-1012"

Basement

3'-1"

2'-6"

5'-412"

3'-4"

2'-43 4

"

Grade

Match exstg. shingles

12

5

12

8

West Elevation

Cantilever Flr. Joist 6' Back

Existing

Existing

Existing

Shingles

12

5

12

8

East Elevation

Shingles

Ute Drive Home

As Built

Power Box

47" P

on

y W

all

96" Clg.

48" Sill48" Sill48" Sill48" Sill

48

" Sill

5' x 35" 6' x 35"8' x 35" 3' x 35"

5' x

35"

92" Clg.92" Clg.92" Clg.92" Clg.

21 1/2" Sill

30" x 5' 6' x 5' 6' x 5'

21 1/2" Sill 21 1/2" Sill 21 1/2" Sill 21 1/2" Sill 21 1/2" Sill

30" x 5' 30" x 5' 30" x 5'

21

1/2

" Sill

21

1/2

" Sill

3' 6

" x 5

'

3' 6

" x 5

'

Up Up

Duct

HVAC WH

Duct

HVACWH

92" Clg.92" Clg.

Washer

Dry

er

11 Treads12 Treads

10

0'

99.5

10

0'

99.5

99.5

99.5

98.7

5

99.8

25

10'

10'-6"

98.7

5

99.8

25

Wa

ter

Se

wer

91.9

17

88.6

67

Pow

er B

ox

HOLLADAY REMODEL AND ADDITION

Bdrm.

Bdrm.

Bdrm.

KitchenSo. Elevation

Living Room

Sink Drain

Wate

r C

lst. D

rain

Do

wn

Additional 3 1/8" x 11"

Current Overhang 4'

Stru

ctu

ral J

ois

t 25

0 S

erie

s 1

1 7

/8"

Le

dg

er U

Hu

ng

@ 1

6" O

.C. - W

/3/4

" T&

G 0

.S.B

.

8"

12'

See Shen Engrg.

Bdrm.

Bath

Bdrm.

Dow

n

Cabs.

Cabs.

6'03'0 Slider

6'03'0 Slider 6'03'0 Slider

3'03'0 Slider

6'0

3'0

Slid

er

12'-5"

4'-0"

New Wall

New Slider6'03'0

New Wall Face4

12

"

2 x 4 Plate

Cut back @ 2' install Knife Joint

(See East Elv. Demo Sht.)

Garage

Garage

8'-0

1 2"

3-1

/2"

24" W x 12" H

Base Bid Full length 30" Below Grade

Alternate Bid - Full Basement

12" W x 12" H

Ne

w T

o M

atc

h

Ne

w T

o M

atc

h

4" Concrete Slab over ftng.

New 3 1/8" x 11"New 3 1/8" x 11" New 3 1/8" x 11"

New 3 1/8" x 11"

Grade

East Elv. Under Design Alternate Bid - Full Basement

4" Concrete Flr.

4" Gravel Sub Grade

Basement Adtn.

1'

Bdrm.

Bath

Bdrm.

Dow

n

Cabs.

6'03'0 Slider

6'03'0 Slider 6'03'0 Slider

3'03'0 Slider

6'0

3'0

Slid

er

LATEST FLOOR PLAN

6'03'0 Slider

New Window

New Wall

Closet

New Wall

New Wall

15'

12'-038

"

11

'-6"

9'-5

1 2"

6'-358

"

10

'-7"

12'-7

1 2"11'-4

18

"

10

'-11

1 2"

38

'-5"

28'-5"

10'-73 4

"

12'-012"

7'-73 4

"

12'-5"

9'-4

1 4"

South Block Elv.

GradeGrade

South Elv.

GradeGrade

Bdrm.

Bdrm.

Bdrm.

Kitchen

Living Room

A.C.Gas

N

Dow

n

Cabs.

Cabs.

Cabs.

Cabs.

Oven

Dirt

Dirt

Dirt

Shed

Water Meter

Cabs.

6'03'0 Slider

6'03'0 Slider 6'03'0 Slider

6'0

3'0

Slid

er

3'03'0 Slider

186'

74

'

178'

Sill 4

2"

Po

we

r

35

X3

5

Sill 4

1"

35

X3

5

Sill 5

7"

35

X 3

8

Sill 3

8"

62

x 3

8

Sill 38"

62" x 42"

Pow

er

Sill 34"

61" x 46"

70" x

42"

Sill 3

8"

24" x 42"

62" x

42"

Sill 3

8"

62" x

42"

Sill 5

4"

24" x

24"

Sill 3

4"

86" x

42"

Sill 74"24" x 36"Sill 37"

Sill 5

4"

24" x

24"

Sill 34"

69" x 46"

Sill 3

5"

West Elv.

Power

East Elv.

Gas

No. Elv.

So. Elv.

COTG

COTG

15'

9'

3'

Water

Sewer

4'

48'-6"

134

'-93 4

"

9'

2'-6"

Ad

jace

nt D

rwy.

Sh

ed

COMMERCIALSLC, UT

4'-512" 4'-6" 4'-6" 4'-6"

8'-238

"5'-9

38

"

80'-114

"

4'-818

" 4'-814

" 4'-814

"

8 1/8"2'-3

14"

9'-5

"

9'-5

"

2'-83 4

"6

'-6

1 4"

6'-6

1 4"

5'-9

1 4"

8 1/8"

15'-018

"

9'-1

1"

6910 So. Redwood Rd. Ste. B

South Elevation

8'2 3/8"

4'-1158

" 4'-878

"

5'-914"

29'-258

"

4'-512" 4'-10

78

" 4'-11"

Sill 2

0 1

/2"

Sill 2

0 1

/2"

N

Elv

. 101.5

9

Elv

. 101.5

9

Elv

. 100

Clg

. 108

Clg

. 114

Elv

. 100

Clg

. 108

Sill 49"

Clg

. 114

PowerPanel

West Elv.

Fndtn. Step

Gas

Power Mtr.

Planter

South Elv.

A.C.

Beam

Fndtn.

2 1/2" Col. 2 1/2" Col.

Fndtn.

North Elv.

Planter

6" outFrom Face

Ceiling 10' 3"

81" Wak Thru Height

7'-2" 7'-5" 9'-3"

Walk Thru Height

Keynotes:

Demo

7'-2" 7'-5" 9'-3"

No

rth

Ceiling Height 10' 3"

6'-1"

Sill Height - 22 1/2"Top of Window - 56 1/2"

(All Windows)

47'-738"

37

'-5

" 30

'-8

"81"

Width 78"

North

47'-738"

37'-5"

Consider KeepingSlope for A.D.A.

Future Wall

Infill Wall

Notes:

Infill Wall

2'-0"21'-1038"

PowerPanel

PowerShut Off

734" Possible Space

To Restaurant

North

As Best as I am

Able to determine

31'-412"

4" Drain

23'-81

2"

4" Drain

11'-0

134"

7'-9"

9'-91

2"

7'-4"

SOUTH JORDAN HOMEADDITION & REMODEL

ROOF CONVERSION

Shed

A.C

.

Gas

8'

7'

120'

91'

Wate

r Mtr.

N

93'

16

52

La

ke

wo

od

Dr., H

olla

da

y, U

T 8

41

17

Gre

g K

elly

Re

sid

en

ce

Add 16" Tie StrapWhere no adt'l.bracing is present

Not to scale

Add Diagonal Bracing @ both sides of trusses

Not to scale

Adt'l. row 2 x 6 blkg. east & west

Dbl. 2 x 12

4 x 6 Post

H 2.5 Simpson @Every other trussOpposite Side

N

Exstg. East Elv.

Gre

g K

elly

Resid

en

ce

Concrete w/Post Base

Exstg. Structural

Structural Sheet

16

52

La

ke

wo

od

Dr., H

olla

da

y, U

T 8

411

7

Adt'l. Blkg.

Adt'l. Blkg.

19/32 OSB

3' Bitu both sides15# Felt

Drip Edge

Asphalt ShinglesRidge Vent

51 4"

Rolled Asphalt

1 x 4 nailer

12

3 1/2

Gre

g K

elly

1652 L

akew

ood D

r., Holla

day, U

T 8

4117

North Elevation

CONCEPTUAL DESIGN

Main Floor Joist

ROOF

top related