atlas em calorimeter

Post on 16-Feb-2016

32 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

ATLAS EM Calorimeter. Jackson Choate. ATLAS Calorimeters. The Science Behind It…. High-energy electrons and photons lose energy primarily through Bremsstrahlung and pair production, respectively. Bremsstrahlung and pair production produce more electrons and photons at lower energies . - PowerPoint PPT Presentation

TRANSCRIPT

ATLAS EM CALORIMETER

Jackson Choate

ATLAS Calorimeters

The Science Behind It… High-energy electrons and photons lose

energy primarily through Bremsstrahlung and pair production, respectively.

Bremsstrahlung and pair production produce more electrons and photons at lower energies.

Science (cont.)We see that for denser media, photons are more likely to produce electron-positron pairs and electrons lose energy predominantly through Bremsstrahlung

Science (cont.)The denser the media, the less energy more massive charged particles lose per unit length.

EM Calorimeter Design To measure the energy of lighter charged

particles and photons, a dense absorber needs to be used with an ionizable medium.

Solution? Lead sheets clad in stainless steel with a liquid argon medium.

Showers in the argon liberate electrons to be collected and recorded.

Argon has the property of being resistant to ionizing and neutron radiations.

EM Calorimeter Barrel

EM Calorimeter Accordion

“Accordion” structure allows for faster readings and reduced dead zones while providing a radiation depth of 24 Xo.

EM Calorimeter Accordion (cont.)

EM Calorimeter End-CapEM Calorimeter End-Cap uses the same accordion structure as the barrel, but positioned orthogonally in a “Spanish Fan” configuration.

However, due to the orientation of the end-caps, this will produce variations in the distance traveled by cascades and affect measurements.

•To minimize the effects of the sampling fraction and argon gap variations, the high voltage (which defines drift velocity) is varied.

•This causes the average drift velocity to remain constant throughout the calorimeter.

Barrel & End-Cap Setup

EM Cryostat

Cryostat maintains the -185 o C temperature to keep the liquid argon from becoming a gas.

EM Calorimeter Data Collection

Simulated result of shower inside of the EM Calorimeter Accordion

1. Presampler – Single thin layer of liquid argon to correct for energy losses in Inner Detector

2. 1st Sampling – Provides excellent resolution for photon/neutral pion separation

3. 2nd Sampling – Clusters below 50 GeV are fully contained

4. 3rd Sampling – Only the highest energy electrons will reach this deep

EM Calorimeter Data Collection

Electrodes are kept at a potential of +2000 V, creating an electric field of 1 MV/m between the absorber and the electrode.

Signals collected at the electrodes are transferred through vacuum-sealed tubes called “feedthroughs.”

These feedthroughs are designed to preserve the signal during the transition from the cold liquid argon to the warmer electronics area.

Schematic of an end-cap feedthrough

Energy Resolution of EM Calorimeter

As seen, the EM Calorimeter has a very precise energy resolution. It’s spatial resolution is also very precise, capable of measuring pseudorapidity and perpendicular plane angles within 0.025 radians.

Works Cited D. M. Gingrich et al. Performance of a large scale prototype of

the ATLAS accordion electromagnetic calorimeter. Nucl. Instrum. Meth., A364:290-306, 1995.

Egede, Ulrik. "The liquid argon calorimeter." N.p., 08 Jan 1998. Web. 3 Nov 2010. <http://www.hep.lu.se/atlas/thesis/egede/thesis-node43.html>.

Froidevaux D, Sphicas P. 2006. Annu. Rev. Nucl. Part. Sci. 56:375 – 440

Krieger, Peter. "The ATLAS Liquid Argon Calorimeter." University of Toronto, 26 OCT <http://www.physics.utoronto.ca/~krieger/talks/Krieger_NSS05_Talk.pdf>

P. Schwemling. The European Physical Journal C - Particles and Fields Volume 34, Supplement 1, s129-s137, DOI: 10.1140/epjcd/s2004-04-014-x

top related