AVS Electronic Circulating Valve

www.intelligentdrillingtools.com

info@idrill.co.uk

Technical Summary IntelligentDrillingToolsintroducetheAnnularVelocitySplitfloworAVSelectroniccirculatingvalvewithsplitflowandfullbypasspositions.AVSisanelectronicmulti-positioncirculatingvalve.TheAVStoolsarenotactivatedbydropballsordartsoranyothertypeofmechanismdeliveredfromsurfacethroughthedrillpipe.Thetoolsareelectronicand intelligent,meaningtheyhaveonboardsensorswithlogicandcanrespondtosurfacecommandssentby“Downlinking”acodedsignaltothetoolviaapatternofpumpson/offandspecificRPMaccordingtoafunctionmap.TheAVStoolsreadthesignalsandshifttotheparticularpositionrequested.

TheAVShas3positions:

1. Through Bore–allthedrillingfluidflowgoesdirectlythroughthetool,BHAandBit.

2. Split Flow–Thisisanopenpositionthatcanbenozzledtoallowacertainamountoftheflowtobediverted into theAnnulus,bypassing theBHA.ThiscanbeengineeredusingIDT’sSplitFlowsoftwaretoallowtheminimumflowrequirementtopowerMWD/RSS/Motor/Bithydraulicsetc.,andtheremainderouttotheannulus.ThismaximisesAnnularVelocityforagivensurfacepressureincreasingHoleCleaningability.

3. Full Bypass–ThispositionopensuptheTotalFlowArea(TFA)furtherandthusallowingmaximumflowratetotheannulusforthehighestAnnularVelocityatthelowestsurfacepressure. In addition, if Lost Circulation Material (LCM) is pumped, the tool can pass150ppbcoarseLCM.AballvalveclosesofftheboretoensurethattheDrillingtoolsandBitdonotbecomeblockedbytheLCMmaterial.

Features Benefits

• No drop balls, Darts or RFID tags • Can be run in any inclination well

• Command via surface Downlink • Can be activated in Horizontal wells • • Simple and Rapid commands • Can be run anywhere in the BHA

• Throughbore at all times • Can be run below an MWD

• Battery powered. Low power draw • Splitflow maximises Annular Velocity

• In excess of 200 cycles • Up to 150ppb LCM through Bypass Position

• Splitflow position with Variable Nozzles • LCM will not enter BHA in Bypass position

• Bypass position with BHA shutoff • Cleans hole while drilling in Splitflow

• 4in2 TFA in full Bypass position • No waiting for Balls and Darts to drop

AVS Applications

TheAVShasmultipleapplicationsincluding:

ü Maximiseholecleaningwhiledrillingü PumpingLCMü Jettingstabiliserspreventingpackoffs

ü RunbehindReamerü SubseaRiser/BOPJettingü HolecleaningwithTaperedString

AVS Electronic Circulating Valve

www.intelligentdrillingtools.com

info@idrill.co.uk

Technical Specification

AVS ToolOD(in) 8.25 ToolID,min(in) 2.36 ToolLength(ft) 17 ToolWeight(tonne) 1.05 TotalFlowArea(in2): Pre-ActivationTFA(ThroughBore) 4.37 SplitFlowTFA(ToAnnulus),min/max* 0.20/0.44 FullBypassTFA(ToAnnulus) 4.00 NumberofPorts 4

NumberofCycles >200 MaximumFlowRate(gpm) 1200

MinimumActivationFlowRate(Water)(gpm)** <400 MaximumDifferentialPressure(psi) 5000 Pre-ActivationPressureDropAcrossTool(Water)(psi) 45@1000gpm MaximumTensileLoad(lbs) 600,000

MaximumTorsionalLoad(ft-lbs) 88,000 MakeupTorque(ft-lbs) 52,000 ToolJointEndConnections(BoxxPin) 65/8APIREG TemperatureRating(°C)max. 150

*NozzleTFAcanbeselectedtofitSplitflowProfile **DependsonBitTFA/hydraulics