DESCRIPTION

BAAB Door is a cost effective solution to meet all the requirements of a sectional overhead door for Garage and Industrial applications whether it is Aluminum or Steel, manually or electrically operated from the right source. Our doors are among the best in the world because we understand your needs. The door system is completely tailor made to meet the correct specifications and requirements of the customer.For more information visit our website www.mei-uae.com

TRANSCRIPT

A. MASONRY GUIDE FIXING

A B

B. STEELWORK GUIDE FIXING

157 95

3030

VerticalSlot

PLAN

CLEAR OPENING WIDTH OF SHUTTER

SOFFIT ANGLE

DIRECT DRIVEMOTOR CLEARANCE

GALVANISEDSTEEL HOOD

150

230184 184 336

DIM C

A

A

L

R

SECTION A - A

OP

ENIN

G H

EIG

HT

130DIM D

ELEVATION DIMENSION A 350 DIMENSION A 350

FITTING SPACE FOR CONTROLS

min 60

SPACE FOR CONNECTING CABLE

190

30

0

HEAD ROOM CLEARANCE (DIM B)

184

FIREFLEX-SFIRE ROLLER SHUTTER - DATA SHEET

TEST: BRE Test report number 220737

ASSESSMENT: Assessment report number CC 224355

INETGRITY: 240 minutes

SHUTTER CURTAINManufactured from pre-galvanized material, 75mm curved lath.The curtain, when assembled is held in position with purposely-designedend fittings, which act as a curtain alignment system. The bottom panel ofthe shutter is terminated with a galvanized steel angle with horizontal andvertical slots.

BARRELManufactured from seamless mild steel tube to BS4760 Grade 50C.Maximum barrel deflection measured at 1:400, fitted with precision-machined BDMS axles to BS970 EN33 with end fitted plate wheel.

MAIN SUPPORT BRACKETSMain support plates for the barrel and motor unit manufactured from mild steel.Support plates to BS 4360/43A with perimeter welded angles and structuresupport angles.

VERTICAL SIDE GUIDESFormed from pre-galvanized material having a minimum thickness of 2.5mm.The door guide is designed to allow reduced working face and tapered innerfaces to provide automatic interlock/retaining feature.

OPERATIONThe door is arranged for an electric motor unit with fusible link or solenoidrelease unit complete with built on starter, or direct drive maintained power.

Technical informationCertificationCE Mark (Declaration of conformity)

Type Approval (Chiltern Dynamics - UKAS approved test laboratory)

Testing Laboratory (BRE Testing – UKAS approved test laboratory)

Compliant with Part 1 BS EN 13241-1: 2003

Mechanical Aspects EN12604, Safety in use of power operated doors.

Side guide protection EN 12604: 2000 4.5.1 and EN 12453: 2000 5.1.1.3

Protection Against crushing, shearing or drawing in

Electrical Safety Depending on the use

Water Tightness EN 12489

Resistance to Wind Load EN 12444

Fire Resistance test B.S.476 : Part 22 : 1987

Integrity 241 minutes (4 hours)

Air permeability EN 12427

Gravity and self-closing EN 12453 - 5.1.1.5

Anti fall back device EN 12453 - 5.1.1.5

Installation Instructions EN 12635: 2002 4.1.1.1

Durability of Mechanical Performance EN 12635: 2002 4.1.1.1

EC Declaration of ConformityAccording to BS EN 13241-1:2003

Manufacturer: Insulated Roller Shutter Products

A DIVISION OF P&D GROUP SERVICES LTD

Product Description: Power operated Roller Shutter Door systems

Equipped with ELEKTROMATEN® Safedrive

Operator sizes 170Nm –1400Nm

Complies with the following EC Guidelines

89/106/ EC Construction Products Directive

73/23EEC Low Voltage Directive

98/37/EC Machinery Directive

89/336/EEC Electromagnetic Compatibility Directive

We hereby certify that the above-mentioned products comply with the following

standards when used accordingly to their determination:

BS EN 13241-1 Annex ZA Water tightness BS EN 12489:2000 Chilt/P05003/01

Resistance to wind load BS EN 12444:2000 Chilt/P05003/01

Air permeability BS EN 12427:2000 Chilt/P05003/01

Operating forces BS EN 12453:2000 Chilt/PO5003/03

Safeguarding against dropping BS EN 12604:2000 TorFV 4/023/024/025/026

Approved Laboratories:

Chiltern Dynamics Stocking Lane, Hughenden Valley High Wycombe HP14 4AD

The Machinery to which this declaration of conformity relates must not be put into service until it has

been completely and safely assembled and installed in accordance with the manufacturers instructions

and not until the complete installation has been declared to be in conformity with the provisions of the

machinery directive.

This declaration is made by

GRAHAM DANKS

MANAGING DIRECTOR

INSULATED ROLLER SHUTTER PRODUCTS

Graham Danks

THETHE

'PROTECTIVEPROTECTIVE'

SOLUTIONSOLUTION

THE

'PROTECTIVE'

SOLUTION

Manufactured by

A Division of P&D Group Services Ltd

C

Door hood addition - Dim B + 50 All Dimensions in mm

WIDTH HEIGHT DIM A DIM B

2500 2500 400 450

3000 3000 450 500

4000 4000 450 500

5000 5000 500 550

6000 6000 550 600

7000 7000 600 650Motor Controlled DescentDirect Drive Power to Close

JOB No:

ORDER No:

OPENING HEIGHT:

OPENING WIDTH:

GUIDE TYPE:

DELIVERY DATE:

DELIVERY ADDRESS:

GENERAL NOTES:

Manufactured by A Division of P&D Group Services Ltd

THETHE

'PROTECTIVEPROTECTIVE'

SOLUTIONSOLUTION

THE

'PROTECTIVE'

SOLUTION

FIRE ROLLER SHUTTER

SHUTTER CURTAINManufactured from pre-galvanizedmaterial, 75mm curved lath.The curtain, when assembled isheld in position with purposelydesigned end fittings, which act asa curtain alignment system. Thebottom panel of the shutter isterminated with a galvanized steelangle with horizontal and verticalslots.

OPERATIONThe door is arranged for an electricmotor unit with fusible link orsolenoid release unit complete withbuilt on starter, or direct drivemaintained power.

FIREFLEX S - THE PROTECTIVE SOLUTION

A. MASONRY GUIDE FIXING

A B

B. STEELWORK GUIDE FIXING

157 95

3030

VerticalSlot

PLAN

CLEAR OPENING WIDTH OF SHUTTER

SOFFIT ANGLE

DIRECT DRIVEMOTOR CLEARANCE

GALVANISEDSTEEL HOOD

150

230184 184 336

DIM C

A

A

L

R

SECTION A - A

OP

ENIN

G H

EIG

HT

130DIM D

ELEVATION DIMENSION A 350 DIMENSION A 350

FITTING SPACE FOR CONTROLS

min 60

SPACE FOR CONNECTING CABLE

190

30

0

HEAD ROOM CLEARANCE (DIM B)

184

C

Door hood addition - Dim B + 50 All Dimensions in mm

WIDTH HEIGHT DIM A DIM B2500 2500 350 450

3000 3000 400 500

4000 4000 400 5505000 5000 450 600

6000 6000 500 650

ORDER INFORMATION

Dock Shelters

Resellers’ price list

Nr. LS09-2

Armo s.p.a. – Via Rosa di Luxemburg, 1 – 10093 Collegno (To) Italy

Tel: +39-011-7176011 Fax: +39-011-7176019

E-mail:info@armoweb.com Web: http://www.armoweb.com

armo armo armo armo

Resellers’ price list

Pag. 2 di 3

Dock shelters are necessary to correctly isolate your staff and goods of your

warehouses from bad weather conditions and sudden variations of temperature.

With the installation of ARMO dock shelters you save on a lot of energy.

STRUCTURE

� Dock shelter with front part in black rubber with differential stiffness.

� Opening/closing device through swinging scissors. The truck, by coming back,

can press the dock shelter structure without causing damages.

� Self-carrying structure in SENDMIR galvanized steel tube, telescopic type, to

deaden possible impacts with trucks.

� Structure front part in pre-painted white steel.

� Frontal realized in anti-wearing black rubber plates with anti-cut warp

� Covering tarpaulin in polyester PVC, anti-flame Class 2

� Warning arrows to centre the truck.

armo armo armo armo

Resellers’ price list

Pag. 3 di 3

Flat roof model PIW-S

Structure characteristics

Outside width mm 3400

Side panels mm 700

Upper panel mm 1000

Outside height mm 3500

Depth mm 650

Flat roof model PIW-T

Structure characteristics

Outside width mm 3400

Side panels mm 700

Upper panel mm 1000

Outside height mm 4500

Depth mm 650

Tech. features can change without advise. This booklet is not to be considered as a contract and all the

information are to be considered as advises. Errors and omissis can be found. Photos and drawings are for

illustration proposal only.

top related