Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 1
PRELIMINARY AND GENERAL ITEMS
PRELIMINARIES & GENERAL
The Tenderer is to allow for all Contract Preliminaries
detailed in Section 3 of the Contract documents and
which he considers necessary to comply with all his
obligations mentioned therein including access to site,
general attendance, security of works, materials, tools
and equipment, supervision and labour, insurances,
possession and completion of works, variations,
fluctuations, terms of payment, antiquities & arbitration Item
Testing and commissioning Item
3 Sets Operation and Maintenance Manuals Item
Handover Item
4 year maintenance Item
One year guarantee Item
The Tenderer is advised that should he require to insert
prices for any items not specifically included in this
section or any other section of this Bill of Quantities and
which he considers necessary in order to comply with all
his obligations under the Contract Documents, He shall
insert the prices in the amount column Item
Contractor should take note that the installations shall
be done in stages floor per floor, i.e, not all floors at
once
CARRIED TO SUMMARY OF BILLS OF QUANTITIES
North Atlantic Engineering Consultants
Lusaka, Zambia 1
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 2
2.0.0 FIRST FLOOR SERVICES
2.1.0 AIR CONDITIOINING SERVICES
Specified Air-conditioning units
Mitsubishi City Multi Y Series' Multiple air-cooled split
Type air-conditioning units with occupancy sesors accessory
of the following types and capacities or equal and approved:
Note
Refrigerant shall be R410A.
2.1.1 Indoor Units
2.1.2 Mitsubishi Multi-Split Ceiling Cassette No. 2
Model PLFY-P32VCM-E or equal and approved
Capacity: 12,300 Btu/hr (Cooling); 13,600 Btu/hr (Heating)
2.1.3 Mitsubishi Multi-Split Ceiling Cassette No. 8
Model PLFY-P63VBM-E or equal and approved
Capacity: 24,200 Btu/hr (Cooling); 24,300 Btu/hr (Heating)
2.1.4 Mitsubishi Multi-Split Ceiling Cassette No. 4
Model PLFY-P50VBM-E or equal and approved
Capacity: 19,100 Btu/hr (Cooling); 21,500 Btu/hr (Heating)
2.1.5 Mitsubishi Multi-Split Ceiling Cassette No. 2
Model PLFY-P40VBM-E or equal and approved
Capacity: 15,400 Btu/hr (Cooling); 17,100 Btu/hr (Heating)
2.1.6 Mitsubishi Multi-Split Ceiling Cassette No. 1
Model PLFY-P25VCM-E or equal and approved
Capacity: 9,600 Btu/hr (Cooling); 10,900 Btu/hr (Heating)
2.1.7 Mitsubishi Multi-Split Ceiling Cassette No. 6
Model PCFY-P125VGM-E or equal and approved
Capacity: 47,800 Btu/hr (Cooling); 54,600 Btu/hr (Heating)
2.1.8 Multi-Split Hideaway as 'Mitsubishi' No. 2
Model PEFFY-P40VMM-E or equal and approved
Capacity: 30,700 Btu/hr (Cooling); 34,100 Btu/hr (Heating)
2.1.9 Outdoor Unit
2.1.10 Mitsubishi PUHY-P950YSHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:385,600 Btu/hr (Cooling);433,300 Btu/hr (Heating) No. 1
2.1.11 Mitsubishi PUHY-P700YSHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:273,000 Btu/hr (Cooling);300,300 Btu/hr (Heating) No. 1
2.1.12 Allow for construction of concrete plinth and erection of the
I-Section beams to support the outdoor unit item
2.1.13 Air Conditioning Accessories
2.1.14 200mm Dia. Flexible duct m 40
2.1.15 935 x 550 mm Return Air Grilles as 'Europair'; type ECA
with OBD Baked Enamel White No. 2
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 2
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
2.1.16 Allow for trunking to cover exposed refigerant pipes from item
hideaway air conditoning units
2.1.17 Refrigerant Piping (including all fittings and insulation
on Tray)
2.1.18 Allow for installation of refrigerant suction and discharge item
pipes
2.1.19 Dia. 32mm Condensate Drain pipe in insulation and fittings m 56
2.1.20 Dia. 50mm Condensate Drain pipe in insulation and fittings m 45
2.1.21 Include drilling through wall for condensate drain pipes Item
2.1.22 Junction Pipe Kits
2.1.23 Allow for the supply and installation of joint kits item
2.1.24 Controllers
2.1.25 PAR-F27MEA-E Local Wired Remote Controller No. 25
(Including chiseling, plastering and painting)
2.1.26 PAC-SF44SRA System Remote Controller No. 1
2.1.27 Existing Airconditioners
2.1.28 Include for removal and handover to client, of existing
wall mounted type air-conditioner in the server room Item
2.1.29 Include for Sealing of openings in walls for existing
wall mounted type air-conditioners (to include plastering and
painting matching the existing wall finish) Item
2.1.30 Allow for removal and handover to Client of the existing
air conditioning piping in the Floor Void. Item
2.2.1 VENTILATION SERVICES
Supply and install the following equipment as recommended
by the manufacturer's manuals and instructions:
2.2.2 Wall/Window mounted Extract Fan as 'Expelair' GX9
or equal and approved
Extract Performance: 728m3/hr
Power Source: 220V/1Phase/50Hz
Power Consumption : 60 Watts No. 5
2.2.3 Wall/Window mounted Extract Fan as 'Expelair' GX12
or equal and approved
Extract Performance: 1614m3/hr
Power Source: 220V/1Phase/50Hz
Power Consumption : 60 Watts No. 1
2.2.4 600 x 600mm Fresh Air Grilles 'Europair'; Type ECA-Egg
Crate; Enamel White Complete with opposed blade dampers No. 9
2.2.5 Constant Ceiling Diffuser as manufactured by 'Europair'
Steel; White;Dimensions 595mm x 595mm
Neck Diameter: 200mm No 2
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 3
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
3.2.8 Xpelair Raper STOF roof fan model: STOF-500HEC-302-0
or equal and approved:
Extract Performance: 9216 cubic metre per second
Power Source: 380V/3phase/50Hz
Power Consumption : 1.96 Kw No. 1
3.2.9 Xpelair Raper STOF roof fan model: STOF-400HAC-302-0
or equal and approved:
Extract Performance: 2340 cubic metre per second
Power Source: 380V/3phase/50Hz
Power Consumption : 0.515 Kw No. 1
3.2.10 Allow for electrical cabling to indoor and outdoor units for the
entire first floor item
3.2.11 Allow for the replacement of damaged ceiling portions to
match the existing ceiling item
3.2.12 1000x900mm 0.6mm thick GI Duct m 6
3.2.13 1000x900mm wire Mesh No. 1
3.3.0 ELECTRICAL SERVICES
3.3.15A Surface Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 22
3.3.25A Flush Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 6
3.3.313A Surface Mounted Single Socket Outlet for Extract Fans
Power Points No. 5
3.3.4 40A SP Weatherproof Industrial Isolator No. 3
3.3.5 Electrical Distribution Board Complete with the following: No. 1
50A TP MCB No. 1
40A SP MCB No. 3
10A SP MCB No. 2
6A SP MCB No. 30
10kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
3.3.6 10mm.sq 4-Core PVC/SWA Armoured Cable M 25
3.3.7 6mm.sq Bare Core Earth Wire Cable M 25
3.3.8
Supply and installation of power points for Extract Fans
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 5
3.3.9
Supply and installation of power points for AC Indoor Units
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 22
3.3.10
Supply and installation of power points for AC Outdoor Units
complete with 6.0mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 3
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 4
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 2
FIRST FLOOR SERVICES
COLLECTION PAGE
Page 2
Page 3
Page 4
CARRIED TO SUMMARY OF BILLS OF QUANTITIES
North Atlantic Engineering Consultants
Lusaka, Zambia 5
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 3
3.0.0 SECOND FLOOR SERVICES
3.1.0 AIR CONDITIONING SERVICES
3.1.1 Specified Air-conditioning units
Mitsubishi City Multi Y Series' Multiple air-cooled split
Type air-conditioning units with occupancy sesors accessory
of the following types and capacities or equal and approved:
Note
Refrigerant shall be R410A.
3.1.2 Indoor Units
3.1.3 Mitsubishi Multi-split Ceiling cassette, No. 12
Model PLFY-P63VBM-E or equal and approved
Capacity: 24,200 Btu/hr (Cooling); 24,300 Btu/hr (Heating)
3.1.4 Mitsubishi Multi-split Ceiling cassette, No. 7
Model PLFY-P50VBM-E or equal and approved
Capacity: 19,100 Btu/hr (Cooling); 21,500 Btu/hr (Heating)
3.1.5 Mitsubishi Multi-split Ceiling cassette, No. 2
Model PLFY-P40VCM-E or equal and approved
Capacity: 15,400 Btu/hr (Cooling); 17,100 Btu/hr (Heating)
3.1.6 Mitsubishi Multi-split Ceiling cassette, No. 4
Model PLFY-P25VCM-E or equal and approved
Capacity: 9,600 Btu/hr (Cooling); 10,900 Btu/hr (Heating)
3.1.7 Outdoor Unit
3.1.8 Mitsubishi PUHY-P550YSHM-A or and approved including
filter dryer and shunt-off valve.
Capacity: 215,000 Btu/hr (Cooling); 235,400 Btu/hr (Heating) No. 1
3.1.9 Mitsubishi PUHY-P600YSHM-A or and approved including
filter dryer and shunt-off valve.
Capacity: 235,000 Btu/hr (Cooling); 261,000 Btu/hr (Heating) No. 1
3.1.10 Allow for construction of concrete plinth and erection of the
I-Section beams to support the outdoor unit item
3.1.11 Single Split Air Conditioning Units
3.1.12 Single split air conditioninng unit as 'Samsung' No. 2
Model AC100FB4DEH
Capacity: 34,100 Btu/hr (Cooling); 38,200 Btu/hr (Heating)
Max. Lenghth (Outdoor to Indoor): 50m (55m)
Max. Lenghth (between outdoor to Indoor): 30m (30m)
3.1.13 Single split air conditioninng unit as 'Samsung' No. 1
Model AC052FBNDEH
Capacity: 17,100 Btu/hr (Cooling); 20,500 Btu/hr (Heating)
Max. Lenghth (Outdoor to Indoor): 30m (35m)
Max. Lenghth (between outdoor to Indoor): 30m (30m)
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 6
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
3.1.14 Single split air conditioninng unit as 'Samsung' No. 1
Model AC071FBNDEH
Capacity: 23,200 Btu/hr (Cooling); 25,600 Btu/hr (Heating)
Max. Lenghth (Outdoor to Indoor): 50m (55m)
Max. Lenghth (between outdoor to Indoor): 30m (30m)
3.1.15 Single split air conditioning Hideaway Unit as 'Samsung' No. 1
Model AM140FNLDEH
Capacity: 47,800 Btu/hr (Cooling); 54,600 Btu/hr (Heating)
Max. Lenghth (Outdoor to Indoor): 30m (35m)
Max. Lenghth (between outdoor to Indoor): 30m (30m)
3.1.16 Refrigerant Piping (including all fittings and insulation
on Tray)
3.1.17 Allow for installation of refrigerant suction and discharge item
pipes
3.1.18 Dia. 32mm Condensate Drain pipe in insulation and fittings m 135
3.1.19 Dia. 50mm Condensate Drain pipe in insulation and fittings m 20
3.1.20 Include drilling through wall for condensate drain pipe Item
3.1.21 Junction Pipe Kits
3.1.22 Allow for supply and installation of joint kits Item
3.1.23 Controllers
3.1.24 PAR-F27MEA-E Local Wired Remote Controller No. 25
(Including chiseling, plastering and painting)
3.1.25 PAC-SF44SRA System Remote Controller No. 5
3.1.26 Existing Air Conditioners
3.1.27 Include for removal and handover to client of existing
air conditioners Item
3.1.28 Include for sealing of openings in walls for existing
air conditioners (to include plastering and painting matching
the existing wall finish) Item
3.1.29 Allow for removal and handover to client of the existing
air conditioning piping in the ceiling void Item
3.1.30 Occupancy Sensors
3.2.1 VENTILATION SERVICES
Supply and install the following equipment as recommended
by the manufacturer's manuals and instructions:
3.2.2 Wall/Window Mounted Extract Fan as 'Expelair' GX6
or equal and approved:
Extract Performance: 250 cubic metre per hour
Power Source: 220V/1Phase/50Hz
Power Consumption: 40 Watts No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 7
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
3.2.3 Wall/Window Mounted Extract Fan as 'Expelair' GX6
or equal and approved:
Extract Performance:728 cubic metre per hour
Power Source: 220V/1Phase/50Hz
Power Consumption: 60 Watts No. 5
3.2.4 600x600mm Fresh Air Grilles 'Europar' ; type ECA-Egg
Crate; Enamel White complete with opposed blade dampers No. 11
3.2.5 Wall/Axial Plate Mounted Extract Fan as 'Flaxt Woods'
H56041
Model HIFLO 560 or equal and approved.
Air Flow: Q = 3.17m/s
Static Pressure: P(st) = 50pa
Power Source: 220V/1Phase/50Hz
Power Consumption: 1.10kW No. 1
3.2.6 600mm x 600mm fixed weather louvre as 'FlaxtWoods'
with Natural Anodised Aluminium No. 1
3.2.7 Extract fan as 'Xpelair' In-Line; XID125
Extract Performance : 375 cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 90 Watts No. 1
3.2.8 Extract fan as 'Xpelair' In-Line; XID315
Extract Performance : 1656 cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 244 Watts No. 1
3.2.9 200mm Neck Diameter White Metallic Disc Valves No. 10
3.2.10 450 x 300mm 0.6mm thick G.I Extract Air Duct m 27
3.2.11 500 x 350mm Weather Louvre as 'Europair'
With Natural Anodised Aluminium No. 2
3.2.12 Constant Volume Supply Diffuser as 'Europair' 600 x 600mm No. 6
3.2.13 700 x 300mm 0.6mm thick G.I Extract Air Duct m 24
3.2.14 600 x 600mm Weather Louvre as 'Europair'
With Natural Anodised Aluminium complete with filter No 1
3.2.15 Allow for electrical cabling to indoor and outdoor units for the
entire second floor item
3.2.16 Allow for the replacement of damaged ceiling portions with
same ceiling as existing item
3.2.17 1000 x 900mm 0.6mm thick GI Duct for outdoor units m 6
3.2.18 1000 x 900mm wire Mesh for outdoor units No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 8
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
3.3.0 ELECTRICAL SERVICES
3.3.15A Surface Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 29
3.3.213A Surface Mounted Single Socket Outlet for Extract Fans
Power Points No. 9
3.3.3 32A SP Weatherproof Industrial Isolator No. 3
3.3.4 Electrical Distribution Board Complete with the following: No. 1
50A TP MCB No. 1
30A SP MCB No. 3
10A SP MCB No. 2
6A SP MCB No. 30
10kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
3.3.5 10mm.sq 4-Core PVC/SWA Armoured Cable M 25
3.3.6 6mm.sq Bare Core Earth Wire Cable M 25
3.3.7
Supply and installation of power points for Extract Fans
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 9
3.3.8
Supply and installation of power points for AC Indoor Units
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 29
3.3.9
Supply and installation of power points for AC Outdoor Units
complete with 4.0mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 3
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 9
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 3
SECOND FLOOR SERVICES
COLLECTION PAGE
Page 6
Page 7
Page 8
Page 9
CARRIED TO SUMMARY OF BILLS OF QUANTITIES
North Atlantic Engineering Consultants
Lusaka, Zambia 10
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 4
4.0.0 THIRD FLOOR SERVICES
4.1.0 AIR CONDITIONING SERVICES
4.1.1 Specified Air-conditioning units
Mitsubishi City Multi Y Series' Multiple air-cooled split
Type air-conditioning units with occupancy sesors accessory
of the following types and capacities or equal and approved:
Note
Refrigerant shall be R410A.
4.1.2 Indoor Units
4.1.3 Mitsubishi Multi-split Ceiling cassette, No. 1
Model PLFY-P80VBM-E or equal and approved
Capacity: 30,700 Btu/hr (Cooling); 34,100 Btu/hr (Heating)
4.1.4 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P63VBM-E or equal and approved
Capacity: 24,200 Btu/hr (Cooling); 24,300 Btu/hr (Heating)
4.1.5 Mitsubishi Multi-split Ceiling cassette, No. 10
Model PLFY-P50VBM-E or equal and approved
Capacity: 19,100 Btu/hr (Cooling); 21,500 Btu/hr (Heating)
4.1.6 Mitsubishi Multi-split Ceiling cassette, No. 5
Model PLFY-P40VBM-E or equal and approved
Capacity: 15,400 Btu/hr (Cooling); 17,100 Btu/hr (Heating)
4.1.7 Mitsubishi Multi-split Ceiling cassette, No. 2
Model PLFY-P25VCM-E or equal and approved
Capacity: 9,600 Btu/hr (Cooling); 10,900 Btu/hr (Heating)
4.1.8 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P32VCM-E or equal and approved
Capacity: 12,300 Btu/hr (Cooling); 13,600 Btu/hr (Heating)
4.1.9 Outdoor Unit
4.1.10 Mitsubishi PUHY-P700YSHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:273,000 Btu/hr (Cooling);300,300 Btu/hr (Heating) No. 1
4.1.11 Mitsubishi PUHY-P450YHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:170,600 Btu/hr (Cooling);191,100 Btu/hr (Heating) No. 1
4.1.12 Allow for construction of concrete plinth and erection of the
I-Section beams to support the outdoor unit item
4.1.13 Single Split Air Conditioning Units
4.1.14 Single split air conditioning unit as 'Samsung' Model
AC052FBNDEH or equal and approved:
Capacity:17,100 Btu/hr (Cooling);20,500 Btu/hr (Heating)
Max. Length (outdoor to indoor) : 30m (35m)
Max. Height (between outdoor and indoor) : 30m (30m)
Power source: 220V/1Phase/50Hz
Power Consumption: 3.15kW No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 11
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
4.1.15 Refrigerant Piping (including all fittings and insulation
on Tray)
4.1.16 Allow for installation of refrigerant suction and discharge item
pipes
4.1.17 Dia. 32mm Condensate Drain pipe in insulation and fittings m 56
4.1.18 Dia. 50mm Condensate Drain pipe in insulation and fittings m 110
4.1.19 Include drilling through wall for condesate drain pipes Item
4.1.20 Junction Pipe Kits
4.1.21 Allow for the supply and installation of joint kits item
4.1.22 Controllers
4.1.23 PAR-F27MEA-E Local Wired Remote Controller No. 24
(Including chiseling, plastering and painting)
4.1.24 PAC-SF44SRA System Remote Controller No. 2
4.1.25 Existing Airconditioners
4.1.26 Include for removal and handover to client, of existing
air-conditioner Item
4.1.27 Include for Sealing of openings in walls for existing
air-conditioners (to include plastering and
painting matching the existing wall finish) Item
4.1.28 Allow for removal and handover to Client of the existing
air conditioning piping in the ceiling Void. Item
4.1.29 Occupancy Sensors
4.2.0 VENTILATION SERVICES
Supply and install the following equipment as recommended
by the maufacturer's manuals and instructions:
4.2.1 Wall/Window Mounted Extract Fan as 'Expelair' GX9
or equal and approved:
Extract Performance: 728m cubic meter per hour
Power Source : 220V/1Phase/50Hz
Power Consumption: 60 Watts No. 3
4.2.2 600 x 600mm Fresh Air Grilles 'Europair'; type ECA- Egg
Crate; Enamel White complete with opposed blade dampers No. 9
4.2.3 Extract fan as 'Xpelair' In-Line; XID150
Extract Performance : 830m cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 104 Watts No. 1
4.2.4 Extract fan as 'Xpelair' In-Line; XID125
Extract Performance : 375m cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 90 Watts No. 1
4.2.5 200mm Diameter White Metallic Disc Valves No. 6
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 12
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
4.2.6 200x200mm 0.6mm thick G.I. Extract Air Duct m 20
4.2.7 300mm x 300mm Weather Louvre as 'Europair'
with Natural Anodised Aluminium m 2
4.2.8 Allow for electrical cabling to indoor and outdoor units for the
entire Third floor item
4.2.9 Allow for the replacement of damaged ceiling portions with
same ceiling as existing item
4.2.10 1000x900mm 0.6mm thick G.I Duct m 6
4.2.11 1000x900mm Wire Mesh No. 1
4.3.0 ELECTRICAL SERVICES
4.3.1
5A Surface Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 25
4.3.2
13A Surface Mounted Single Socket Outlet for Extract Fans
Power Points No. 5
4.3.3 32A SP Weatherproof Industrial Isolator No. 1
4.3.4 Electrical Distribution Board Complete with the following: No. 1
40A TP MCB No. 1
30A SP MCB No. 1
6A SP MCB No. 27
10kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
4.3.5 10mm.sq 4-Core PVC/SWA Armoured Cable M 25
4.3.6 6mm.sq Bare Core Earth Wire Cable M 25
4.3.7
Supply and installation of power points for Extract Fans
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 5
4.3.8
Supply and installation of power points for AC Indoor Units
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 25
4.3.9
Supply and installation of power points for AC Outdoor Units
complete with 4.0mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 1
TOTAL AMOUNT CARRIED TO TOTAL SUMMARY
North Atlantic Engineering Consultants
Lusaka, Zambia 13
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 4
THIRD FLOOR SERVICES
COLLECTION PAGE
Page 11
Page 12
Page 13
TOTAL AMOUNT CARRIED TO TOTAL SUMMARY
North Atlantic Engineering Consultants
Lusaka, Zambia 14
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 5
5.0.0 FOURTH FLOOR SERVICES
5.1.0 AIR CONDITIONING SERVICES
5.1.1 Specified Air-conditioning units
Mitsubishi City Multi Y Series' Multiple air-cooled split
Type air-conditioning units with occupancy sesors accessory
of the following types and capacities or equal and approved:
Note
Refrigerant shall be R410A.
5.1.2 Indoor Units
5.1.3 Mitsubishi Multi-split Ceiling cassette, No. 6
Model PLFY-P80VBM-E or equal and approved
Capacity: 30,700 Btu/hr (Cooling); 34,100 Btu/hr (Heating)
5.1.4 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P63VBM-E or equal and approved
Capacity: 24,200 Btu/hr (Cooling); 24,300 Btu/hr (Heating)
5.1.5 Mitsubishi Multi-split Ceiling cassette, No. 1
Model PLFY-P50VBM-E or equal and approved
Capacity: 19,100 Btu/hr (Cooling); 21,500 Btu/hr (Heating)
5.1.6 Mitsubishi Multi-split Ceiling cassette, No. 6
Model PLFY-P40VBM-E or equal and approved
Capacity: 15,400 Btu/hr (Cooling); 17,100 Btu/hr (Heating)
5.1.7 Mitsubishi Multi-split Ceiling cassette, No. 2
Model PLFY-P25VCM-E or equal and approved
Capacity: 9,600 Btu/hr (Cooling); 10,900 Btu/hr (Heating)
5.1.8 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P32VCM-E or equal and approved
Capacity: 12,300 Btu/hr (Cooling); 13,600 Btu/hr (Heating)
5.1.9 Outdoor Unit
5.1.10 Mitsubishi PUHY-P800YSHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:307,000 Btu/hr (Cooling);341,200 Btu/hr (Heating) No. 1
5.1.11 Mitsubishi PUHY-P350YHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:136,500 Btu/hr (Cooling);153,500 Btu/hr (Heating) No. 1
5.1.12 Allow for construction of concrete plinth and erection of the
I-Section beams to support the outdoor unit item
5.1.13 Single Split Air Conditioning Units
5.1.14 Single split air conditioning unit as 'Samsung' Model
AC052FBNDEH or equal and approved:
Capacity:17,100 Btu/hr (Cooling);20,500 Btu/hr (Heating)
Max. Length (outdoor to indoor) : 30m (35m)
Max. Height (between outdoor and indoor) : 30m (30m)
Power Consumption: 3.15kW No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 15
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
5.1.15 Refrigerant Piping (including all fittings and insulation
on Tray)
5.1.16 Allow for installation of refrigerant suction and discharge item
pipes
5.1.17 Dia. 32mm Condensate Drain pipe in insulation and fittings m 56
5.1.18 Dia. 50mm Condensate Drain pipe in insulation and fittings m 45
5.1.19 Include drilling through wall for condesate drain pipes Item
5.1.20 Junction Pipe Kits
5.1.21 Allow for the supply and installation of joint kits item
5.1.22 Controllers
5.1.23 PAR-F27MEA-E Local Wired Remote Controller No. 21
(Including chiseling, plastering and paiting)
5.1.24 PAC-SF44SRA System Remote Controller No. 2
5.1.25 Existing Airconditioners
5.1.26 Include for removal and handover to client, of existing
air-conditioners Item
5.1.27 Include for Sealing of openings in walls for existing
air-conditioners (to include plastering and
painting matching the existing wall finish) Item
5.1.28 Allow for removal and handover to Client of the existing
air conditioning piping in the ceiling Void. Item
5.1.29 Occupancy Sensors
5.2.0 VENTILATION SERVICES
Supply and install the following equipment as recommended
by the manufacturer's manuals and instructions:
5.2.1 Wall/Window Mounted Extract Fan as 'Expelair' GX9
or equal and approved:
Extract Performance: 728m cubic meter per hour
Power Source : 220V/1Phase/50Hz
Power Consumption: 60 Watts No. 1
5.2.2 600 x 600mm Fresh Air Grilles 'Europair'; type ECA- Egg
Crate; Enamel White complete with opposed blade dampers No. 8
5.2.3 Extract fan as 'Xpelair' In-Line; XID125
Extract Performance : 375m cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 90 Watts No. 1
5.2.4 200mm Diameter White Metallic Disc Valves No. 3
5.2.5 300x300mm 0.6mm thick G.I. Extract Air Duct m 20
5.2.6 300mm x 300mm Weather Louvre as 'Europair' m 2
with Natural Anodised Aluminium
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 16
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
5.2.7 Allow for electrical cabling to indoor and outdoor units for the
entire Fourth floor item
5.2.8 Allow for the replacement of damaged ceiling portions with
same ceiling as existing item
5.2.9 1000x900mm 0.6mm thick G.I Duct m 6
5.2.10 1000x900mm Wire Mesh No. 1
5.3.0 ELECTRICAL SERVICES
5.3.15A Surface Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 22
5.3.213A Surface Mounted Single Socket Outlet for Extract Fans
Power Points No. 5
5.3.3 32A SP Weatherproof Industrial Isolator No. 1
5.3.4 Electrical Distribution Board Complete with the following: No. 1
40A TP MCB No. 1
30A SP MCB No. 1
6A SP MCB No. 24
10kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
5.3.5 10mm.sq 4-Core PVC/SWA Armoured Cable M 25
5.3.6 6mm.sq Bare Core Earth Wire Cable M 25
5.3.7
Supply and installation of power points for Extract Fans
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 5
5.3.8
Supply and installation of power points for AC Indoor Units
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 22
5.3.9
Supply and installation of power points for AC Outdoor Units
complete with 4.0mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 17
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 5
FOURTH FLOOR SERVICES
COLLECTION PAGE
Page 15
Page 16
Page 17
CARRIED TO SUMMARY OF BILLS OF QUANTITIES
North Atlantic Engineering Consultants
Lusaka, Zambia 18
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 6
FIFTH FLOOR SERVICES
6.1.0 AIR CONDITIONING SERVICES
6.1.1 Specified Air-conditioning units
Mitsubishi City Multi Y Series' Multiple air-cooled split
Type air-conditioning units with occupancy sesors accessory
of the following types and capacities or equal and approved:
Note
Refrigerant shall be R410A.
6.1.2 Indoor Units
6.1.3 Mitsubishi Multi-split Ceiling cassette, No. 9
Model PLFY-P80VBM-E or equal and approved
Capacity: 30,700 Btu/hr (Cooling); 34,100 Btu/hr (Heating)
6.1.4 Mitsubishi Multi-split Ceiling cassette, No. 2
Model PLFY-P63VBM-E or equal and approved
Capacity: 24,200 Btu/hr (Cooling); 24,300 Btu/hr (Heating)
6.1.5 Mitsubishi Multi-split Ceiling cassette, No. 1
Model PLFY-P50VBM-E or equal and approved
Capacity: 19,100 Btu/hr (Cooling); 21,500 Btu/hr (Heating)
6.1.6 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P40VBM-E or equal and approved
Capacity: 15,400 Btu/hr (Cooling); 17,100 Btu/hr (Heating)
6.1.7 Mitsubishi Multi-split Ceiling cassette, No. 2
Model PLFY-P25VCM-E or equal and approved
Capacity: 9,600 Btu/hr (Cooling); 10,900 Btu/hr (Heating)
6.1.8 Mitsubishi Multi-split Ceiling cassette, No. 10
Model PLFY-P32VCM-E or equal and approved
Capacity: 12,300 Btu/hr (Cooling); 13,600 Btu/hr (Heating)
6.1.9 Outdoor Unit
6.1.10 Mitsubishi PUHY-P800YSHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:307,000 Btu/hr (Cooling);341,200 Btu/hr (Heating) No. 1
6.1.11 Mitsubishi PUHY-P550YHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:215,000 Btu/hr (Cooling);235,400 Btu/hr (Heating) No. 1
6.1.12 Allow for construction of concrete plinth and erection of the
I-Section beams to support the outdoor unit item
6.1.13 Single Split Air Conditioning Units
6.1.14 Single split air conditioning unit as 'Samsung' Model
AC052FBNDEH or equal and approved:
Capacity:17,100 Btu/hr (Cooling);20,500 Btu/hr (Heating)
Max. Length (outdoor to indoor) : 30m (35m)
Max. Height (between outdoor and indoor) : 30m (30m)
Power source: 220V/1Phase/50Hz
Power Consumption: 3.15kW No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 19
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
6.1.15 Refrigerant Piping (including all fittings and insulation
on Tray)
6.1.16 Allow for installation of refrigerant suction and discharge item
pipes
6.1.17 Dia. 32mm Condensate Drain pipe in insulation and fittings m 56
6.1.18 Dia. 50mm Condensate Drain pipe in insulation and fittings m 45
6.1.19 Include drilling through wall for condesate drain pipes Item
6.1.20 Junction Pipe Kits
6.1.21 Allow for the supply and installation of joint kits item
6.1.22 Controllers
6.1.23 PAR-F27MEA-E Local Wired Remote Controller No. 26
(Including chiseling, plastering and painting)
6.1.24 PAC-SF44SRA System Remote Controller No. 2
6.1.25 Existing Airconditioners
6.1.26 Include for removal and handover to client, of existing
air-conditioners Item
6.1.27 Include for Sealing of openings in walls for existing
air-conditioners (to include plastering and
painting matching the existing wall finish) Item
6.1.28 Allow for removal and handover to Client of the existing
air conditioning piping in ceiling void Item
6.1.29 Occupancy Sensors No. 13
6.2.0 VENTILATION SERVICES
Supply and install the following equipment as recommended
by the manufacturer's manuals and instructions:
6.2.1 Wall/Window Mounted Extract Fan as 'Expelair' GX9
or equal and approved:
Extract Performance: 728m cubic meter per hour
Power Source : 220V/1Phase/50Hz
Power Consumption: 60 Watts No. 3
6.2.2 600 x 600mm Fresh Air Grilles 'Europair'; type ECA- Egg
Crate; Enamel White complete with opposed blade dampers No. 10
6.2.3 Extract fan as 'Xpelair' In-Line; XID150
Extract Performance : 830m cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 104 Watts No. 1
6.2.4 Extract fan as 'Xpelair' In-Line; XID100
Extract Performance : 250m cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 67 Watts No. 1
6.2.5 200mm Diameter White Metallic Disc Valves No. 7
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 20
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Unit Qty. Rate Amount
K
6.2.6 300x300mm 0.6mm thick G.I. Extract Air Duct m 20
6.2.7 300mm x 300mm Weather Louvre as 'Europair'
with Natural Anodised Aluminium m 3
6.2.8 Allow for electrical cabling to indoor and outdoor units for the
entire Fifth floor item
6.2.9 Allow for the replacement of damaged ceiling portions with
same ceiling as existing item
6.2.10 1000x900mm 0.6mm thick G.I Duct m 6
6.2.11 1000x900mm Wire Mesh No. 1
6.3.0 ELECTRICAL SERVICES
6.3.15A Surface Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 28
6.3.213A Surface Mounted Single Socket Outlet for Extract Fans
Power Points No. 6
6.3.3 32A SP Weatherproof Industrial Isolator No. 1
6.3.4 Electrical Distribution Board Complete with the following: No. 1
40A TP MCB No. 1
30A SP MCB No. 1
6A SP MCB No. 30
10kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
6.3.5 10mm.sq 4-Core PVC/SWA Armoured Cable M 25
6.3.6 6mm.sq Bare Core Earth Wire Cable M 25
6.3.7
Supply and installation of power points for Extract Fans
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 6
6.3.8
Supply and installation of power points for AC Indoor Units
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 28
6.3.9
Supply and installation of power points for AC Outdoor Units
complete with 4.0mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 21
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 6
AIR CONDITIONING SERVICES
COLLECTION PAGE
Page 19
Page 20
Page 21
TOTAL AMOUNT CARRIED TO TOTAL SUMMARY
North Atlantic Engineering Consultants
Lusaka, Zambia 22
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 7
7.0.0 SIXTH FLOOR SERVICES
7.1.0 AIR CONDITIONING SERVICES
7.1.1 Specified Air-conditioning units
Mitsubishi City Multi Y Series' Multiple air-cooled split
Type air-conditioning units with occupancy sesors accessory
of the following types and capacities or equal and approved:
Note
Refrigerant shall be R410A.
7.1.2 Indoor Units
7.1.3 Mitsubishi Multi-split Ceiling cassette, No. 8
Model PLFY-P80VBM-E or equal and approved
Capacity: 30,700 Btu/hr (Cooling); 34,100 Btu/hr (Heating)
7.1.4 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P63VBM-E or equal and approved
Capacity: 24,200 Btu/hr (Cooling); 24,300 Btu/hr (Heating)
7.1.5 Mitsubishi Multi-split Ceiling cassette, No. 3
Model PLFY-P50VBM-E or equal and approved
Capacity: 19,100 Btu/hr (Cooling); 21,500 Btu/hr (Heating)
7.1.6 Mitsubishi Multi-split Ceiling cassette, No. 5
Model PLFY-P40VBM-E or equal and approved
Capacity: 15,400 Btu/hr (Cooling); 17,100 Btu/hr (Heating)
7.1.7 Mitsubishi Multi-split Ceiling cassette, No. 2
Model PLFY-P25VCM-E or equal and approved
Capacity: 9,600 Btu/hr (Cooling); 10,900 Btu/hr (Heating)
7.1.8 Mitsubishi Multi-split Ceiling cassette, No. 4
Model PLFY-P32VCM-E or equal and approved
Capacity: 12,300 Btu/hr (Cooling); 13,600 Btu/hr (Heating)
7.1.9 Outdoor Unit
7.1.10 Mitsubishi PUHY-P700YSHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:273,000 Btu/hr (Cooling);300,300 Btu/hr (Heating) No. 1
7.1.11 Mitsubishi PUHY-P600YHM-A or equal and approved
including filter dryer and shunt-off valve.
Capacity:235,000 Btu/hr (Cooling);261,000 Btu/hr (Heating) No. 1
7.1.12 Allow for construction of concrete plinth and erection of the
I-Section beams to support the outdoor unit item
7.1.13 Single Split Air Conditioning Units
7.1.14 Single split air conditioning unit as 'Samsung' Model
AC052FBNDEH or equal and approved:
Capacity:17,100 Btu/hr (Cooling);20,500 Btu/hr (Heating)
Max. Length (outdoor to indoor) : 30m (35m)
Max. Height (between outdoor and indoor) : 30m (30m)
Power source: 220V/1Phase/50Hz
Power Consumption: 3.15kW No. 1
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 23
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
7.1.15 Refrigerant Piping (including all fittings and insulation
on Tray)
7.1.16 Allow for installation of refrigerant suction and discharge item
pipes
7.1.17 Dia. 32mm Condensate Drain pipe in insulation and fittings m 56
7.1.18 Dia. 50mm Condensate Drain pipe in insulation and fittings m 45
7.1.19 Include drilling through wall for condesate drain pipes Item
7.1.20 Junction Pipe Kits
7.1.21 Allow for the supply and installation of joint kits item
7.1.22 Controllers
7.1.23 PAR-F27MEA-E Local Wired Remote Controller No. 25
(Including chiseling, plastering and paiting)
7.1.24 PAC-SF44SRA System Remote Controller No. 2
7.1.25 Existing Airconditioners
7.1.26 Include for removal and handover to client, of existing
wall mounted type air-conditioner in the server room Item
7.1.27 Include for Sealing of openings in walls for existing
air-conditioners (to include plastering and
painting matching the existing wall finish) Item
7.1.28 Allow for removal and handover to Client of the existing
air conditioning piping in the Ceiling Void. Item
7.1.29 Occupancy Sensors No. 18
7.2.0 VENTILATION SERVICES
Supply and install the following equipment as recommended
by the manufacturer's manuals and instructions:
7.2.1 Wall/Window Mounted Extract Fan as 'Expelair' GX9
or equal and approved:
Extract Performance: 728 cubic meter per hour
Power Source : 220V/1Phase/50Hz
Power Consumption: 60 Watts No. 3
7.2.2 600 x 600mm Fresh Air Grilles 'Europair'; type ECA- Egg
Crate; Enamel White complete with opposed blade dampers No. 9
7.2.3 Extract fan as 'Xpelair' In-Line; XID125
Extract Performance : 375 cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 90 Watts No. 1
7.2.4 Extract fan as 'Xpelair' In-Line; XID100
Extract Performance : 250 cubic meter per hour
Power Source : 220V/1phase/50Hz
Power Consumption: 67 Watts No. 1
7.2.5 200mm Diameter White Metallic Disc Valves No. 7
CARRIED TO COLLECTION PAGE
North Atlantic Engineering Consultants
Lusaka, Zambia 24
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
7.2.6 0.6mm thick G.I. Extract Air Duct m 20
7.2.7 300mm x 300mm Weather Louvre as 'Europair'
with Natural Anodised Aluminium m 3
7.2.8 Allow for electrical cabling to indoor and outdoor units for the
entire sixth floor Item
7.2.9 Allow for the replacement of damaged ceiling portions with
same ceiling as existing Item
7.2.10 1000x900mm 0.6mm thick GI Duct m 6
7.2.11 1000x900mm Wire Mesh No. 1
7.3.0 ELECTRICAL SERVICES
7.3.15A Surface Mounted Single Socket Outlet for AC Indoor Units
Power Points No. 26
7.3.213A Surface Mounted Single Socket Outlet for Extract Fans
Power Points No. 5
7.3.3 32A SP Weatherproof Industrial Isolator No. 1
7.3.4 Electrical Distribution Board Complete with the following: No. 1
40A TP MCB No. 1
30A SP MCB No. 1
6A SP MCB No. 27
10kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
7.3.5 10mm.sq 4-Core PVC/SWA Armoured Cable M 25
7.3.6 6mm.sq Bare Core Earth Wire Cable M 25
7.3.7
Supply and installation of power points for Extract Fans
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 5
7.3.8
Supply and installation of power points for AC Indoor Units
complete with 2.5mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 26
7.3.9
Supply and installation of power points for AC Outdoor Units
complete with 4.0mm.sq PVC/SWA armoued cable + Earth,
draw boxes, conduiting and all associated installation
accessories
No. 1
8.0.0 Removal of obsolete equipment
Allow for Removal of all obsolete air conditioning equipment
on 8th floor plant room
CARRIED TO SUMMARY OF BILLS OF QUANTITIES
North Atlantic Engineering Consultants
Lusaka, Zambia 25
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
9.0.0 8th FLOOR ELECTRICAL SERVICES
9.1.0 32A TP Weatherproof Industrial Isolator No. 1
9.1.1 50A TP Weatherproof Industrial Isolator No. 5
9.1.2 63A TP Weatherproof Industrial Isolator No. 3
9.1.3 80A TP Weatherproof Industrial Isolator No. 2
9.1.4 100A TP Weatherproof Industrial Isolator No. 1
9.1.5 Electrical Distribution Board Complete with the following: No. 1
32A TP MCB No. 1
50A TP MCB No. 5
63A TP MCB No. 3
80A TP MCB No. 2
100A TP MCB No. 1
500A TP MCCB No. 1
35kA Surge Arrestors No. 3
Neutral Bar Item 1
Earth Bar Item 1
9.1.6 6mm.sq 4-Core PVC/SWA Armoured Cable M 30
9.1.7 16mm.sq4-CorePVC/SWA Armoured Cable M 300
9.1.8 25mm.sq 4-CorePVC/SWA Armoured Cable M 30
9.1.9 120mm.sq 4-Core PVC/SWA Armoured Cable M 200
9.1.10 4mm.sq Bare Core Earth Wire Cable M 30
9.1.11 10mm.sq Bare Core Earth Wire Cable M 300
9.1.12 16mm.sq Bare Core Earth Wire Cable M 30
9.1.13 120mm.sq Bare Core Earth Wire Cable M 100
9.1.14300mm Wide Heavy Duty Wire Mesh Cable Tray complete
with mounting and installation accessories M 100
CARRIED TO SUMMARY OF BILLS OF QUANTITIES
North Atlantic Engineering Consultants
Lusaka, Zambia 26
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
BILL No. 7
AIR CONDITIONING SERVICES
COLLECTION PAGE
Page 23
Page 24
Page 25
Page 26
TOTAL AMOUNT CARRIED TO TOTAL SUMMARY
North Atlantic Engineering Consultants
Lusaka, Zambia 27
-
Bank of Zambia, Excutive Building, Lusaka Proposed Air Conditioning and Ventilation Services
Item Description Unit Qty. Rate Amount
K
8.0.0 SUMMARY OF BILLS OF QUANTITIES
8.1.0 Bill No. 1
PRELIMINARY AND GENERAL ITEMS
8.2.0 Bill No. 2
FIRST FLOOR SERVICES
8.3.0 Bill No. 3
SECOND FLOOR SERVICES
Bill No. 4
8.4.0 THIRD FLOOR SERVICES
Bill No. 5
8.5.0 FOURTH FLOOR SERVICES
Bill No. 6
8.6.0 FIFTH FLOOR SERVICES
Bill No. 7
8.7.0 SIXTH FLOOR SERVICES
Contingency Sum @ 5%
Sub-total
Add VAT @ 16.0%
TOTAL AMOUNT CARRIED TO FORM OF TENDER
North Atlantic Engineering Consultants
Lusaka, Zambia 28