catalogue online turbidity/refract/viscosity meters · ipr process ‐ refractometer 1.1. process...
Post on 16-Mar-2020
11 Views
Preview:
TRANSCRIPT
1 www.milktronics.com 352-508-1296 info@milktronics.com
Catalogue Online Turbidity/refract/viscosity meters
Index Page
Turbidity VOM 0-6000NTU 2
Turbidity VOD 0-1500NTU 3
Turbidity VOF 0-1500NTU 4
Turbidity Drain sewer meter 5
Turbidity Meter selection chart 6
Rotary PASVE pH 7
Refractometers 8
1. IPR Process ‐ Refractometer
1.1. Process Refractometer IPR Compact2
1.2. Process Refractometer IPR Basic3
1.3. Process Refractometer IPR FR2 (Full Range)
1.4. Process Refractometer IPR HR2 (High Resolution)
Viscosity meter 12
2 www.milktronics.com 352-508-1296 info@milktronics.com
VOM Relative turbidity meters
Applications: phase separation, filter monitoring, Yeast, CIP, Food, waste water…
Product information and specs click here: Product informations and spces
Turbidity meter without display VOM
Range 0-6000NTU, ppm, % g/L….
High temperature process option available 302F
HART Protocol/USB port/ AISI316L/ duplex/ HAST/Titanium
Wavelength 880nm, 640nm
Price ≈ 2,500.00$ (Options: HT+500$, Kalrez +200$)
4-20mA output
Turbidity meter display VOM
Range 0-6000NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength 880nm, 640nm
Price≈ 3,000.00$ (options : HT+500$, Kalrez +200$)
4-20mA output for turbidity + 4-20mA output for temperature
Turbidity meter remote display VOM
Range 0-6000NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength 880nm, 640nm
Price ≈ 3,900.00$ ( options : HT+500$, Kalrez +200$)
4-20mA output for turbidity + 4-20mA output for temperature
Turbidity meter display and tri-clamp VOM
Range 0-6000NTU, ppm,%, g/L….
High temperature process option available 302F
HART Protocol/ AISI316L/ duplex/ HAST/Titanium
Wavelength 880nm, 640nm
Price≈ 3,100.00$ (options : HT+500$, Kalrez +200$)
4-20mA output for turbidity + 4-20mA output for temperature
3 www.milktronics.com 352-508-1296 info@milktronics.com
VOD Turbidity/Absorption meters
Applications on low turbidity: RO, UF, COW Breach detection, water impurities,
COD, Calcium, Color, soft drink, protein, lactoferin, sugar filter…
Turbidity /absorption meter with display VOD
Range 0-5-10-100-150….1500NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength NIR 880nm, Blue 460nm, UV 365nm
Price≈ 3,900.00$ (options : HT+500$, Kalrez +200$, UV+500$)
4-20mA output for turbidity + 4-20mA output for temperature
Varinline pipe : 1” 600.00$, 1,5” 750.00$, 2” 850.00$,
2,5” 950.00$, 3” 1,100.00$, 4” 1,400.00$
The pipe comes with tri-clamps and 2 blanking plates
Other process fittings available
Turbidity /absorption meter remote display VOD
Range 0-5-10-100-150….1500NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength NIR 880nm, Blue 460nm, UV 365nm
Price ≈ 4,400.00$ (options : HT+500$, Kalrez +200$, UV+500$)
4-20mA output for turbidity + 4-20mA output for temperature
Varinline pipe : 1” 600.00$, 1,5” 750.00$, 2” 850.00$,
2,5” 950.00$, 3” 1,100.00$, 4” 1,400.00$
The pipe comes with tri-clamps and 2 blanking plates
Other process fittings available
4 www.milktronics.com 352-508-1296 info@milktronics.com
VOF Turbidity/Absorption meters
Applications: phase transition, waste water, protein, color…
Procedure to retract the sensor during operation click here: retractable procedure
Turbidity /absorption meter display tri-clamp VOF
Range 0-5-10-100-150….1500NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength NIR 880nm, Blue 460nm
Price≈ 4,500.00$ (options: HT+500$, Kalrez +200$)
4-20mA output for turbidity + 4-20mA output for temperature
All fittings available (varivant, tri-clamp flange, I-Line etc.)
Turbidity /absorption meter ball valve, no display VOF
Range 0-5-10-100-150….1500NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength NIR 880nm, Blue 460nm
Price≈ 4,400.00$ (options: HT+500$, Kalrez +200$)
4-20mA output for turbidity
Turbidity /absorption meter remote display ball valve VOF
Range 0-5-10-100-150….1500NTU, ppm, %, g/L….
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength NIR 880nm, Blue 460nm
Price≈ 5,200.00$ (options : HT+500$, Kalrez +200$)
4-20mA output for turbidity + 4-20mA output for temperature
Turbidity /absorption meter automatic cleaning
2bar air pressure is sprayed on the lens, the cleaning
Frequency can be set by the PLC or the sensor parameters.
Price: +600$
5 www.milktronics.com 352-508-1296 info@milktronics.com
Turbidity meter to install in drains or sewers
Turbidity /absorption meter remote electronics VOF
Range 0-5-10-100-150….1500NTU, ppm, %, g/L….
Price ≈ 5,000.00$
Range: 0-6000NTU, ppm, %, g/L….
Price ≈ 4,000.00$
Cable stainless steel / remote electronics, 100% water proof
High temperature process option available 302F
HART Protocol/USB port / AISI316L/ duplex/ HAST/Titanium
Wavelength NIR 880nm, Blue 460nm
4-20mA output for turbidity + 4-20mA output for temperature
Pit system
7 www.milktronics.com 352-508-1296 info@milktronics.com
PASVE pH service valve
pH probe rotary service valve datasheet
PASVE rotary pH service valve
AISI316L/ duplex/ HAST/Titanium
Price ≈ 2,200.00$ AISI316L manual operated
Price ≈ 4,000.00$ AISI316L automatic operated
8 www.milktronics.com 352-508-1296 info@milktronics.com
Process Refractometer
iPR Compact2 ID‐N°
Price / unit
in US$
Automatically operating process refractometer to control, monitor and record
Dissolved solids. Stainless steel or anodized aluminum sensor, without display.PC
Software
General specifications:
Measuring range: 1.3320 ‐ 1.4209 RI
0 ‐ 50 Brix (with ATC)
Resolution 0.0001 RI / 0.05 Brix
Precision: ±0.0002 RI / ± 0,15 Brix at 20°C
ATC range Brix: 10 ‐ 50°C
Process temperature: ‐10 ... 80°C
Max. process pressure: up to 10 bar
Power supply: 24 V DC
Light source: 589 nm LED
Data output: 4‐20 mA
PC connection: RS232, RS422 or USB
Dimension: 150 mm x Ø 65 mm
Weight. 1000 g
Models:
iPR‐C2 S Stainless steel sensor 10310 5,880.00
iPR‐C2 Al Anodized aluminium sensor 10780 5,376.00
iPR‐C2 S Like IPR‐C2 S but with higher precision (±0.0001 RI / ±0.1 Brix) 14158 6,120.00
Connecting flanges (1 flanging type per sensor possible, please specify)
Joint Tuchenhagen VariVent 05510 264.00
connection APV 05520 312.00
Connection Tri‐Clamp 13279 312.00
9 www.milktronics.com 352-508-1296 info@milktronics.com
IPR Basic3
ID‐N° Price / unit
in US$
Stainless steel sensor with integrated electronics without display
The configuration is done through a Windows based software program.
‐ Air cooling
‐ Single solution, visualization of the measuring data on the data logger
‐ Sensor connected to superior process control system
‐ PC Software
Specifications:
IPR Basic3 Resolution: 0.01 Brix / 0.00001 RI
Precision: ± 0.1 Brix / ± 0.00014 RI at 20°C
Measuring ranges: 1.32 ‐ 1.52 RI / 0 ‐ 90 Brix
Process temperature: ‐10 ... 80°C
Environment temperature: 0 °C ‐ 40 °C
Pressure load capacity: up to 10 bar (depending on process flange)
External power supply: 20 V ‐ 30 V DC (at 24 V and 0,11 A)
Output's: one serial interface RS 232, RS 485 or USB
two 4‐20 mA current outputs/ limit switches 1A
Models: Introduction
price
IPR Basic3 IPR‐Basic3‐VariVent 12609 8,508.00
IPR‐Basic3‐Tri‐Clamp 12612 8,640.00
IPR‐Basic3‐APV 12613 8,640.00
10 www.milktronics.com 352-508-1296 info@milktronics.com
IPR FR2 ID‐N°
Price / unit
in US$
Stainless steel sensor with integrated electronics and display
The configuration is done through a Windows based software program. Joints for
water cooling jacket as standard.
‐ Single solution, visualization of the measuring data on the data logger
‐ Sensor connected to superior process control system
‐ PC Software
Specifications:
IPR FR2 Measuring range: 1.3320 ‐ 1.5300 RI / 0 ‐ 100 Brix
Resolution : 0.01 Brix / 0.00001 RI
Precision: ± 0.05 Brix / ± 0.00007 RI at 20°C
Process temperature: ‐10 ... 150°C (with water cooling)
Environment temperature: 0 °C ‐ 45 °C
Pressure load capacity: up to 10 bar (depending on process flange)
External power supply: 20 V ‐ 30 V DC (at 24 V and 0,11 A)
Output's: one serial interface RS 232, RS 485 or USB
two 4‐20 mA current outputs/ limit switches 1A
Models:
IPR FR2 IPR‐FR2‐VariVent 10970 11,040.00
IPR‐FR2‐Tri‐Clamp 10971 11,040.00
IPR‐FR2‐APV 10972 11,040.00
IPR HR2 (High Resolution) ID‐N° Price / unit
in US$
Stainless steel sensor with integrated electronics and display
The configuration is done through a Windows based software program. Joints for
water cooling jacket as standard.
‐ Single solution, visualization of the measuring data on the data logger
‐ Sensor connected to superior process control system
‐ PC Software
Specifications:
Measuring range: 1.3320 ‐ 1.3720 / 0 ‐ 25 Brix
Resolution: 0.000005 RI / 0.002 Brix
Precision: ± 0.00004 RI / ± 0.02 Brix at 20°C
± 0.01 Brix (range up to 2% Brix)
Process temperature: ‐10 ... 100°C
Environment temperature: 0 °C ‐ 45 °C
Pressure load capacity: up to 10 bar (depending on process flange)
External power supply: 20 V ‐ 30 V DC (at 24 V and 0,11 A)
Output's: one serial interface RS 232, RS 485 or USB
two 4‐20 mA current outputs/ limit switches 1A
Model:
IPR HR2 IPR‐HR2‐VariVent 10990 11,200.00
IPR‐HR2‐Tri‐Clamp 10991 11,600.00
IPR‐HR2‐APV 10992 11,600.00
Hydramotion Online Viscosity meter
11 www.milktronics.com 352-508-1296 info@milktronics.com
XL7 process viscometer data for hygienic processes
The XL7 transducer can be supplied in a range of sizes with virtually any process fitting. The XL7-100 model
with a flanged connection is shown below as an example.
12 www.milktronics.com 352-508-1296 info@milktronics.com
XL7 viscometer
Range 0 to 1,000,000,000 cP
Accuracy ±1% of reading
Repeatability ±0.3% of reading
Temperature
standard: –40 to +150 °C HT2 high temp: up to 400 °C
Pressure to process connection
Process
connection to suit application
Safety certification
All instruments also available as intrinsically safe IEC Ex ia versions
Overall length 443 mm (standard)
Materials
all 316 stainless steel
(standard); other materials on request
Construction all-welded crevice-free
wetted parts
Finish standard: high polish optional: electropolish; PTFE coated
Environmental rating
IP68
VP550 signal processor
Power supply 24V DC @ 150 mA (including transducer)
Inputs (optional)
• temperature (PRT or 4-20mA analogue) • density (4-20mA analogue) • pressure (4-20mA analogue)
Outputs
3 x 4 - 20 mA analogue,
fully configurable, representing either viscosity or referenced viscosity • RS485 ModBus serial link
Environmental
rating IP65
Safety certification
Safe Area
Features
• Viscosity correction to standard conditions
• 2-off volt-free contact outputs
Options USB output
INTRINSIC SAFETY
HYGIENIC
HIGH TEMPERATURE
INSTALLATION
13 www.milktronics.com 352-508-1296 info@milktronics.com
Contacts: Andrea Dehec President Andrea.dehec@milktronics .com Cell: 352-602-6404 Office: 352-508-1296 Sylvain Dehec Technical Director Sylvain.dehec@milktronics.com Cell: 678-619-9268 Office : 352-508-1296 Website: www.milktronics.com