Page 1 of 22
PERRY JOHNSON LABORATORY
ACCREDITATION, INC.
Certificate of Accreditation
Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:
AG Metrology® S.r.l. Strada San Faustino, 155 N, 41124 Modena (MO) Italy
(Hereinafter called the Organization) and hereby declares that Organization is accredited
in accordance with the recognized International Standard:
ISO/IEC 17025:2017
This accreditation demonstrates technical competence or a defined scope and the
operation of a laboratory quality management system
(as outlined by the joint ISO-ILAC-IAF Communiqué dated April 2017):
Electrical, Mechanical, and Thermodynamic Calibration (As detailed in the supplement)
Accreditation claims Or such testing and/or calibration services shall only be made addresses referenced within this certificate.
This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization
hereby covenants with the Accreditation body’s duty to observe and comply with the said rules.
Initial Accreditation Date: Issue Date: Expiration Date:
May 8, 2020 May 8, 2020 July 31, 2022
Revision Date: Accreditation No.: Certificate No.:
July 6, 2021 108949 L20-291-R1
The validity of this certificate is maintained through ongoing assessments based on a
continuous accreditation cycle. The validity of this certificate should be
confirmed through the PJLA website: www.pjlabs.com
Or PJLA:
Tracy Szerszen
President
Perry Johnson Laboratory
Accreditation, Inc. (PJLA)
755 W. Big Beaver, Suite 1325
Troy, Michigan 48084
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 2 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Equipment to Measure DC
VoltageF
Up to 100 mV 0.001 2 % of reading + 1.2 µV Datron 1271
Datron 4700
Euramet cg-15
Sit/Tec-008/05
0.1 to 1 V 0.001 1 % of reading + 2.0 µV
1 V to 10 V 0.000 83 % of reading + 12 µV
10 V to 100 V 0.001 1 % of reading + 0.21 mV
100 V to 1 000 V 0.001 2 % of reading + 2.4 mV
Equipment to Measure DC
CurrentF Up to 100 µA 0.007 2 % of reading + 2.6 nA
0.1 µA to 1 mA 0.006 5 % of reading + 19 nA
1 mA to 10 mA 0.006 5 % of reading + 0.19 µA
10 mA to 100 mA 0.011 % of reading + 2.2 µA
0.1 mA to 1 A 0.019 % of reading + 50 µA
Equipment to Measure
ResistanceF Up to 10 Ω 0.004 5 % of reading + 0.41 mΩ Datron 1271
Fluke 5450A
GenRad 1433F
Euramet cg-15
Sit/Tec-008/05
10 Ω to 100 Ω 0.0032 % of reading + 4.1 mΩ
0.1 kΩ to 1 kΩ 0.002 4 % of reading + 41 mΩ
1 kΩ to 10 kΩ 0.002 7 % of reading + 0.41Ω
10 kΩ to 100 kΩ 0.002 6 % of reading + 4.1 Ω
1 Ω 0.11 mΩ
1.9 Ω 0.17 mΩ
10 Ω 0.52 mΩ
19 Ω 0.90 mΩ
100 Ω 3.4 mΩ
190 Ω 4.8 mΩ
1 kΩ 24 mΩ
1.9 kΩ 50 mΩ
10 kΩ 0.23 Ω
19 kΩ 0.48 Ω
100 kΩ 2.6 Ω
190 kΩ 7.8 Ω
1 MΩ 50 Ω
1.9 MΩ 0.22 kΩ
10 MΩ 1.0 kΩ
19 MΩ 15 kΩ
100 MΩ 69 kΩ
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 3 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Equipment to Output DC
VoltageF
Up to 100 mV 0.001 1 % of reading + 0.49 µV Datron 1271
CEM EL-010
Sit/Tec-008/05 0.1 V to 1 V 0.000 83 % of reading + 1.8 µV
1 V to 10 V 0.000 72 % of reading + 6.3 µV
10 V to 100 V 0.000 83 % of reading + 0.12 mV
100 V to 1 000 V 0.001 1 % of reading + 2.1 mV
Equipment to Output DC
CurrentF
Up to 100 µA 0.005 1 % of reading + 1.3 nA
0.1 mA to 1 mA 0.005 1 % of reading + 7.9 nA
1 mA to 10 mA 0.0051 % of reading + 79 nA
10 mA to 100 mA 0.011 % of reading + 1.3 µA
0.1 A to 1 A 0.016 % of reading + 24 µA
Equipment to Output
ResistanceF
Up to 10 Ω 0.011 % of reading + 0.11 mΩ
10 Ω to 100 Ω 0.002 9 % of reading + 0.42 mΩ
0.1 kΩ to 1 kΩ 0.002 6 % of reading + 4.2 mΩ
1 kΩ to 10 kΩ 0.002 6 % of reading + 42 mΩ
10 kΩ to 100 kΩ 0.002 6 % of reading + 0.42 Ω
0.1 MΩ to 1 MΩ 0.003 6 % of reading + 5.4 Ω
1 MΩ to 10 MΩ 0.021 % of reading + 0.23 kΩ
10 MΩ to 100 MΩ 0.073 % of reading + 14.2 kΩ
0.1 GΩ to 1 GΩ 0.43 % of reading + 1.1 MΩ
Equipment to Measure DC
VoltageO
Up to 200 mV 0.002 2 % of reading + 3.5 µV Datron 1271
MicroCal 20 DPC
Euramet cg-15
Sit/Tec-008/05
0.2 V to 2 V 0.002 2 % of reading + 16 µV
2 V to 20 V 0.002 2 % of reading + 0.17 mV
Equipment to Measure DC
CurrentO
Up to 50 mA 0.023 % of reading + 1.1 µA
Equipment to Measure
ResistanceO
Up to 500 Ω 0.021 % of reading + 24 mΩ
0.5 kΩ to 5 kΩ 0.021 % of reading + 0.24 Ω
Equipment to Measure AC Voltage At the Listed FrequenciesF Datron 1271
Datron 4700
Euramet cg-15
Sit/Tec-008/05
40 Hz to 2 kHz Up to 100 mV 0.034 % of reading + 18 µV
2 kHz to 20 kHz Up to 100 mV 0.046 % of reading + 27 µV
20 kHz to 100 kHz Up to 100 mV 0.18 % of reading + 46 µV
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 4 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Equipment to Measure AC Voltage At the Listed FrequenciesF Datron 1271
Datron 4700
Euramet cg-15
Sit/Tec-008/05
40 Hz to 2 kHz Up to 100 mV 0.034 % of reading + 18 µV
2 kHz to 20 kHz Up to 100 mV 0.046 % of reading + 27 µV
20 kHz to 100 kHz Up to 100 mV 0.18 % of reading + 46 µV
Equipment to Measure AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 0.1 V to 1 V 0.029 % of reading + 0.11 mV
2 kHz to 20 kHz 0.1 V to 1 V 0.030 % of reading + 0.11 mV
20 kHz to 100 kHz 0.1 V to 1 V 0.12 % of reading + 0.41 mV
100 kHz to 300 kHz 0.1 V to 1 V 1.5 % of reading + 21 mV
300 kHz to 1 MHz 0.1 V to 1 V 2.1 % of reading + 41 mV
Equipment to Measure AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 1 V to 10 V 0.029 % of reading + 1.1 mV
2 kHz to 20 kHz 1 V to 10 V 0.029 % of reading + 1.1 mV
20 kHz to 100 kHz 1 V to 10 V 0.12 % of reading + 4.1 mV
100 kHz to 300 kHz 1 V to 10 V 1.1 % of reading + 0.21 V
300 kHz to 1 MHz 1 V to 10 V 2.1 % of reading + 0.41 V
Equipment to Measure AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 10 V to 100 V 0.025 % of reading + 11 mV
2 kHz to 20 kHz 10 V to 100 V 0.025 % of reading + 11 mV
20 kHz to 100 kHz 10 V to 100 V 0.11 % of reading + 41 mV
Equipment to Measure AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 100 V to 1 000 V 0.037 % of reading + 0.16 V
2 kHz to 20 kHz 100 V to 1 000 V 0.035 % of reading + 0.25 V
20 kHz to 100 kHz 100 V to 1 000 V 0.17 % of reading + 0.45 V
Equipment to Output AC Voltage At the Listed FrequenciesF Datron 1271
CEM EL-010
Sit/Tec-008/05
40 Hz to 2 kHz Up to 100 mV 0.026 % of reading + 15 µV
2 kHz to 20 kHz Up to 100 mV 0.041 % of reading + 13 µV
20 kHz to 100 kHz Up to 100 mV 0.17 % of reading + 45 µV
Equipment to Output AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 0.1 V to 1 V 0.021 % of reading + 0.11 mV
2 kHz to 20 kHz 0.1 V to 1 V 0.03 % of reading + 53 µV
20 kHz to 100 kHz 0.1 V to 1 V 0.11 % of reading + 0.41 mV
100 kHz to 300 kHz 0.1 V to 1 V 1.1 % of reading + 11 mV
300 kHz to 1 MHz 0.1 V to 1 V 2.1 % of reading + 41 mV
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 5 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Equipment to Output AC Voltage At the Listed FrequenciesF Datron 1271
CEM EL-010
Sit/Tec-008/05 40 Hz to 2 kHz 1 V to 10 V 0.021 % of reading + 1.1 mV
2 kHz to 20 kHz 1 V to 10 V 0.021 % of reading + 0.51 mV
20 kHz to 100 kHz 1 V to 10 V 0.11 % of reading + 4.1 mV
100 kHz to 300 kHz 1 V to 10 V 1.1 % of reading + 0.11 V
300 kHz to 1 MHz 1 V to 10 V 2.1 % of reading + 0.41 V
Equipment to Output AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 10 V to 100 V 0.021 % of reading + 11 mV
2 kHz to 20 kHz 10 V to 100 V 0.021 % of reading + 5.1 mV
20 kHz to 100 kHz 10 V to 100 V 0.11 % of reading + 41 mV
Equipment to Output AC Voltage At the Listed FrequenciesF
40 Hz to 2 kHz 100 V to 1 000 V 0.026 % of reading + 0.15 V
2 kHz to 20 kHz 100 V to 1 000 V 0.031 % of reading + 0.13 V
20 kHz to 100 kHz 100 V to 1 000 V 0.17 % of reading + 0.45 V
Equipment to Measure AC Current At the Listed FrequenciesF Datron 1271
Datron 4700
Euramet cg-15
Sit/Tec-008/05
CEM EL-010
10 Hz to 5 kHz Up to 100 µA 0.069 % of reading + 33 nA
10 Hz to 5 kHz 0.1 mA to 1 mA 0.048 % of reading + 0.30 µA
10 Hz to 5 kHz 1 mA to 10 mA 0.048 % of reading + 2.7 µA
10 Hz to 5 kHz 10 mA to 100 mA 0.048 % of reading + 27 µA
10 Hz to 5 kHz 0.1 A to 1 A 0.17 % of reading + 0.84 mA
Equipment to Output AC Current At the Listed FrequenciesF Datron 1271
CEM EL-010
Sit/Tec-008/05
10 Hz to 5 kHz Up to 100 µA 0.041 % of reading + 33 nA
10 Hz to 5 kHz 0.1 mA to 1 mA 0.032 % of reading + 0.24 µA
10 Hz to 5 kHz 1 mA to 10 mA 0.032 % of reading + 2.2 µA
10 Hz to 5 kHz 10 mA to 100 mA 0.032 % of reading + 21 µA
10 Hz to 5 kHz 0.1 A to 1 A 0.16 % of reading + 0.81 mA
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type Pt/PdF
0 °C to 1 500 °C 0.17 °C with 0 °C RJ
0.35 °C with internal RJ
Electrical Simulation
of Thermocouple
Output Using Datron
4700
Euramet cg-11
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 6 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type Au/PtF
0 °C to 1 000 °C 0.15 °C with 0° C RJ
0.35 °C with internal RJ
Electrical Simulation
of Thermocouple
Output Using Datron
4700
Euramet cg-11 Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type RF
-50 °C to 1 768 °C 0.21 °C with 0° C RJ
0.44 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type SF
-50 °C to 1 768 °C 0.20 °C with 0° C RJ
0.44 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type BF
420 °C to 1 820 °C 0.20 °C with 0° C RJ
0.42 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type JF
-200 °C to 1 200 °C 0.04 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type TF
-200 °C to 400 °C 0.055 °C with 0° C RJ
0.20 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type EF
-200 °C to 1 000 °C 0.035 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type KF
-200 °C to 1 300 °C 0.057 °C with 0° C RJ
0.20 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type NF
-200 °C to 1 300 °C 0.087 °C with 0° C RJ
0.21 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type CF
0 °C to 2 310 °C 0.11 °C with 0° C RJ
0.21 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type AF
0 °C to 2 500 °C 0.13 °C with 0° C RJ
0.20 °C with internal RJ
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 7 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature simulation
use with Thermocouple
Type PtPdF
0 °C to 1 500 °C 0.068 °C with 0 °C RJ Electrical measure of
Thermocouple input
Using Datron 1271
Euramet cg-11
0.32 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type AuPtF
0 °C to 1 000 °C 0.059 °C with 0° C RJ
0.32 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type RF
-50 °C to 1 768 °C 0.088 °C with 0° C RJ
0.40 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type SF
-50 °C to 1 768 °C 0.084 °C with 0° C RJ
0.40 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type BF
420 °C to 1 820 °C 0.084 °C with 0° C RJ
0.38 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type JF
-200 °C to 1 200 °C 0.018 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type TF
-200 °C to 400 °C 0.024 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type EF
-200 °C to 1 000 °C 0.016 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type KF
-200 °C to 1 300 °C 0.025 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type NF
-200 °C to 1 300 °C 0.037 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type CF
0 °C to 2 310 °C 0.046 °C with 0° C RJ
0.19 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type AF
0 °C to 2 500 °C 0.054 °C with 0° C RJ
0.20 °C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with RTDF
-200 °C to 850 °C 0.055 °C Electrical Simulation
of Resistance
thermometer Output
Using General Radio
1433-F
Euramet cg-11
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 8 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature Simulation
use with Resistance
thermometerF
-200 °C to 850 °C 0.023 °C Electrical measure of
Resistance
thermometer input
Using Datron 1271
Euramet cg-11
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type Pt/PdO
0 °C to 1 500 °C 0.44°C with 0 °C RJ
0.54°C with internal RJ
Electrical Simulation
of Thermocouple
Output Using MicroCal
20 DPC
Euramet cg-11
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type
Au/PtO
0 °C to 1 000 °C 0.38°C with 0 °C RJ
0.49°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type RO
-50 °C to 1 768 °C 0.56°C with 0 °C RJ
0.68°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type SO
-50 °C to 1 768 °C 0.54°C with 0 °C RJ
0.66°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type BO
420 °C to 1 820 °C 0.54°C with 0 °C RJ
0.65°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type JO
-200 °C to 1 200 °C 0.15°C with 0 °C RJ
0.24°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type TO
-200 °C to 400 °C 0.16°C with 0 °C RJ
0.24°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type EO
-200 °C to 1 000 °C 0.13°C with 0 °C RJ
0.22°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type KO
-200 °C to 1 300 °C 0.19°C with 0 °C RJ
0.27°C with internal RJ
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 9 of 22
Electrical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type NO
-200 °C to 1 300 °C 0.24°C with 0 °C RJ
0.30°C with internal RJ
Electrical Simulation
of Thermocouple
Output Using MicroCal
20 DPC
Euramet cg-11
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type CO
0 °C to 2 310 °C 0.53°C with 0 °C RJ
0.56°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
Thermocouple Type AO
0 °C to 2 500 °C 0.59°C with 0 °C RJ
0.62°C with internal RJ
Temperature Calibration,
Indication and Control
Equipment used with
RTDO
-200 °C to 850 °C 0.17 °C Electrical Simulation
of Resistance
thermometer Output
Using MicroCal 20
DPC
Euramet cg-11
Temperature simulation
use with Thermocouple
Type PtPdO
0 °C to 1 500 °C 0.82 °C with 0 °C RJ
0.88 °C with internal RJ
Electrical measure of
Thermocouple input
Using Agilent 34970A
Euramet cg-11 Temperature Simulation
use with Thermocouple
Type AuPtO
0 °C to 1 000 °C
0.72 °C with 0° C RJ
0.78 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type RO
-50 °C to 1 768 °C 1.1 °C with 0° C RJ
1.2 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type SO
-50 °C to 1 768 °C 1.1 °C with 0° C RJ
1.1 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type BO
420 °C to 1 820 °C 1.1 °C with 0° C RJ
1.1 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type JO
-200 °C to 1 200 °C 0.20 °C with 0° C RJ
0.27 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type TO
-200 °C to 400 °C 0.28 °C with 0° C RJ
0.34 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type EO
-200 °C to 1 000 °C 0.18 °C with 0° C RJ
0.26 °C with internal RJ
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 10 of 22
Electrical
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND MEASUREMENT
CAPABILITY EXPRESSED AS AN
UNCERTAINTY (±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature Simulation
use with Thermocouple
Type KO
-200 °C to 1300 °C 0.29 °C with 0° C RJ
0.34 °C with internal RJ
Electrical measure of
Thermocouple input
Using Agilent 34970A
Euramet cg-11 Temperature Simulation
use with Thermocouple
Type NO
-200 °C to 1300 °C 0.44 °C with 0° C RJ
0.48 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type CO
0 °C to 2310 °C 0.51 °C with 0° C RJ
0.54 °C with internal RJ
Temperature Simulation
use with Thermocouple
Type AO
0 °C to 2500 °C 0.60 °C with 0° C RJ
0.63 °C with internal RJ
Temperature Simulation
use with Resistance
ThermometerO
-200 °C to 850 °C 0.17 °C Electrical measure of
Resistance
thermometer input
Using Agilent 34970A
Euramet cg-11
Certificate of Accreditation: Supplement
AG Metrology S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 11 of 22
Mechanical MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Absolute Pneumatic
Pressure transducers,
pressure transmitters,
manometersF
Up to 172 kPa 0.007 7 % of reading + 1.9 Pa Ruska 2465
Euramet Calibration
Guide No. 17 172 kPa to 7 MPa 0.005 9 % of reading + 7.0 Pa
In gas:
Gage Pneumatic
Pressure transducers,
pressure transmitters,
manometers F
Up to 172 kPa 0.007 9 % of reading + 1.5 Pa
172 kPa to 7 MPa 0.005 9 % of reading + 6.8 Pa
In gas:
Gage Pneumatic
Pressure transducers,
pressure transmitters,
manometers F
Up to 7 MPa 0.011 % of reading + 3.5 Pa Druck DPI 515
Euramet Calibration
Guide No. 17 7 MPa to 21 MPa 0.012 % of reading + 0.23 kPa
Gage Oil
Pressure transducers,
pressure transmitters,
manometers F
Up to 16 MPa 0.007 3 % of reading +63 Pa Ruska 2400
Euramet Calibration
Guide No. 17 16MPa to 83 MPa 0.007 2 % of reading + 7.1 Pa
In gas:
Gage Pneumatic
Pressure transducers,
pressure transmitters,
manometersO
Up to 7 Mpa 0.017 % of reading + 3 Pa MicroCal 20 DPC
Euramet Calibration
Guide No. 17
Gage Oil
Pressure transducers,
pressure transmitters,
manometersO
Up to 35 MPa 0.017 % of reading + 0.11 kPa
Certificate of Accreditation: Supplement
AG Metrology S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 12 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature measurement
Thermocouple Pt/PdF
0 °C to 150°C 0.24 °C Fluke 7380
Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
PRT Fluke 5628
Thermocouple Pt/Pd
Datron 1271
Fluke 1590
ASTM E220
ASTM E2846
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.24 °C
420 °C to 600 °C 0.28 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple AuPt F
0 °C to 150°C 0.24 °C
150 °C to 420 °C 0.24 °C
420 °C to 600 °C 0.28 °C
600 °C to 1 000 °C 0.91 °C
Temperature measurement
Thermocouple R F
-50 °C to 150°C 0.33 °C
150 °C to 420 °C 0.23 °C
420 °C to 600 °C 0.28 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple S F
-50 °C to 150°C 0.33 °C
150 °C to 420 °C 0.23 °C
420 °C to 600 °C 0.28 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple BF
150 °C to 420 °C 0.31 °C
420 °C to 600 °C 0.28 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple J F
-80 °C to 150°C 0.15 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.31 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 200 °C 1.6 °C
Temperature measurement
Thermocouple T F
-80 °C to 150°C 0.15 °C
150 °C to 400 °C 0.25 °C
Temperature measurement
Thermocouple E F
-80 °C to 150°C 0.15 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.31 °C
600 °C to 1 000 °C 1.3 °C
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 13 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature measurement
Thermocouple K F
-80 °C to 150°C 0.15 °C Fluke 7380
Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
PRT Fluke 5628
Thermocouple Pt/Pd
Datron 1271
Fluke 1590
ASTM E220
ASTM E2846
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.31 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C Temperature measurement
Thermocouple N F
-80 °C to 150°C 0.15 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.31 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Temperature measurement
Thermocouple C F
0 °C to 150°C 0.15 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.31 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Temperature measurement
Thermocouple A F
0 °C to 150°C 0.15 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.31 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Temperature measurement
Thermocouple Pt/Pd O
0 °C to 150°C 0.79 °C Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
PRT Fluke 5628
Thermocouple Pt/Pd
Agilent 34970A
ASTM E220
ASTM E2846
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.67 °C
420 °C to 600 °C 0.48 °C
600 °C to 1 050 °C 0.96 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple AuPt O
0 °C to 150°C 0.70 °C
150 °C to 420 °C 0.67 °C
420 °C to 600 °C 0.36 °C
600 °C to 1 000 °C 0.96 °C
Certificate of Accreditation: Supplement
AG Metrology S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 14 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature measurement
Thermocouple R O
-40 °C to 150°C 1.1 °C Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
PRT Fluke 5628
Thermocouple Pt/Pd
Agilent 34970A
ASTM E220
ASTM E2846
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.55 °C
420 °C to 600 °C 0.46 °C
600 °C to 1 050 °C 0.99 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple S O
-40 °C to 150°C 0.99 °C
150 °C to 420 °C 0.56 °C
420 °C to 600 °C 0.50 °C
600 °C to 1 050 °C 1.0 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple B O
150 °C to 420 °C 2.7 °C
420 °C to 600 °C 0.96 °C
600 °C to 1 050 °C 1.1 °C
1 050 °C to 1 300 °C 1.3 °C
Temperature measurement
Thermocouple J O
-40 °C to 150°C 0.18 °C
150 °C to 420 °C 0.27 °C
420 °C to 600 °C 0.34 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 200 °C 1.6 °C
Temperature measurement
Thermocouple TO
-40°C to 150°C 0.19 °C
150°C to 400°C 0.27 °C
Temperature measurement
Thermocouple EO
-40 °C to 150°C 0.17 °C
150 °C to 420 °C 0.27 °C
420 °C to 600 °C 0.34 °C
600 °C to 1 000 °C 1.3 °C
Temperature measurement
Thermocouple KO
-40 °C to 150°C 0.19 °C
150 °C to 420 °C 0.28 °C
420 °C to 600 °C 0.35 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 15 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature measurement
Thermocouple NO
-40 °C to 150°C 0.19 °C Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
PRT Fluke 5628
Thermocouple Pt/Pd
Agilent 34970A
ASTM E220
ASTM E2846
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.28 °C
420 °C to 600 °C 0.35 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Temperature measurement
Thermocouple CO
0 °C to 150°C 0.34 °C
150 °C to 420 °C 0.34 °C
420 °C to 600 °C 0.40 °C
600 °C to 1 050 °C 1.4 °C
1 050 °C to 1 300 °C 1.6 °C
Temperature measurement
Thermocouple AO
0 °C to 150°C 0.34 °C
150 °C to 420 °C 0.34 °C
420 °C to 600 °C 0.40 °C
600 °C to 1 050 °C 1.4 °C
1 050 °C to 1 300 °C 1.6 °C
Temperature measurement
RTD and thermistor F
-80 °C to 150 °C 0.038 °C Fluke 7380
Additel 875-155
Additel 875-660
SPRT Rosemount 162CE
PRT Fluke 5628
Datron 1271
Fluke 1590
ASTM E644
ASTM E2593
150 °C to 420 °C 0.11 °C
420 °C to 600 °C 0.24 °C
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 16 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Temperature measurement
RTD and thermistor O
-40°C to 150°C 0.18 °C Additel 875-155
Additel 875-660
SPRT Rosemount 162CE
PRT Fluke 5628
Agilent 34970A
ASTM E644
ASTM E2593
150°C to 420°C 0.25 °C
420°C to 600°C 0.36 °C
Digital thermometer used
with Thermocouple PtPd F
0 °C to 150°C 0.25 °C Fluke 7380
Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
Fluke 5628
Thermocouple PtPd
Datron 1271
Fluke 1590
ASTM E220
ASTM E2846
ASTM E2877
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.27 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple AuPt F
0 °C to 150°C 0.25 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.27 °C
600 °C to 1 000 °C 0.91 °C
Digital thermometer used
with Thermocouple R F
-50 °C to 150°C 0.34 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.27 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple S F
-50 °C to 150°C 0.34 °C
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.27 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple B F
150 °C to 420 °C 0.25 °C
420 °C to 600 °C 0.27 °C
600 °C to 1 050 °C 0.91 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple J F
-80 °C to 150 °C 0.12 °C
150 °C to 420 °C 0.23 °C
420 °C to 600 °C 0.30 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 200 °C 1.6 °C
Digital thermometer used
with Thermocouple T F
-80°C to 150°C 0.12 °C
150°C to 400°C 0.23 °C
Certificate of Accreditation: Supplement
AG Metrology S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 17 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Digital thermometer used
with Thermocouple E F
-80 °C to 150°C 0.11 °C Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
Fluke 5628
Thermocouple PtPd
Datron 1271
ASTM E220
ASTM E2846
ASTM E2877
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.23 °C
420 °C to 600 °C 0.30 °C
600 °C to 1 000 °C 1.3 °C
Digital thermometer used
with Thermocouple K F
-80 °C to 150°C 0.12 °C
150 °C to 420 °C 0.23 °C
420 °C to 600 °C 0.30 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Digital thermometer used
with Thermocouple N F
-80 °C to 150°C 0.12 °C
150 °C to 420 °C 0.23 °C
420 °C to 600 °C 0.30 °C
600 °C to 1 050 °C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Digital thermometer used
with Thermocouple C F
0°C to 150°C 0.11 °C
150°C to 420°C 0.23 °C
420°C to 600°C 0.30 °C
600°C to 1 050°C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Digital thermometer used
with Thermocouple A F
0°C to 150°C 0.14 °C
150°C to 420°C 0.24 °C
420°C to 600°C 0.31 °C
600°C to 1 050°C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 18 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Digital thermometer used
with Thermocouple PtPdO
0 °C to 150°C 0.29 °C Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
Fluke 5628
Thermocouple PtPd
Agilent 34970A
ASTM E220
ASTM E2846
ASTM E2877
Euramet Calibration
Guide No. 8
150 °C to 420 °C 0.30 °C
420 °C to 600 °C 0.35 °C
600 °C to 1 050 °C 0.94 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple AuPtO
0 °C to 150°C 0.29 °C
150 °C to 420 °C 0.30 °C
420 °C to 600 °C 0.35 °C
600 °C to 1 000 °C 0.94 °C
Digital thermometer used
with Thermocouple RO
-40°C to 150°C 0.36 °C
150°C to 420°C 0.30 °C
420°C to 600°C 0.35 °C
600°C to 1 050°C 0.94 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple S O
-40°C to 150°C 0.36 °C
150°C to 420°C 0.30 °C
420°C to 600°C 0.35 °C
600°C to 1 050°C 0.94 °C
1 050 °C to 1 300 °C 1.3 °C
Digital thermometer used
with Thermocouple BO
150°C to 420°C 0.30 °C
420°C to 600°C 0.35 °C
600°C to 1 050°C 0.94 °C
1 050 °C to 1 300 °C 1.3 °C
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 19 of 22
Thermodynamic
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Digital thermometer used
with Thermocouple J O
-40°C to 150°C 0.19 °C Additel 875-155
Additel 875-660
Nabertherm RD
30/200/13
SPRT Rosemount 162CE
Fluke 5628
Thermocouple PtPd
Agilent 34970A
ASTM E220
ASTM E2846
ASTM E2877
Euramet Calibration
Guide No. 8
150°C to 420°C 0.30 °C
420°C to 600°C 0.37 °C
600°C to 1 050°C 1.3 °C
1 050 °C to 1 200 °C 1.6 °C
Digital thermometer used
with Thermocouple TO
-40°C to 150°C 0.19 °C
150°C to 400°C 0.30 °C
Digital thermometer used
with Thermocouple EO
-40°C to 150°C 0.19 °C
150°C to 420°C 0.30 °C
420°C to 600°C 0.37 °C
600°C to 1 000°C 1.3 °C
Digital thermometer used
with Thermocouple KO
-40°C to 150°C 0.19 °C
150°C to 420°C 0.30 °C
420°C to 600°C 0.37 °C
600°C to 1 050°C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Digital thermometer used
with Thermocouple NO
-40°C to 150°C 0.19 °C
150°C to 420°C 0.30 °C
420°C to 600°C 0.38 °C
600°C to 1 050°C 1.3 °C
1050 °C to 1 300 °C 1.6 °C
Digital thermometer used
with Thermocouple CO
0°C to 150°C 0.18 °C
150°C to 420°C 0.30 °C
420°C to 600°C 0.37 °C
600°C to 1 050°C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Digital thermometer used
with Thermocouple AO
0°C to 150°C 0.20 °C
150°C to 420°C 0.31 °C
420°C to 600°C 0.38 °C
600°C to 1 050°C 1.3 °C
1 050 °C to 1 300 °C 1.6 °C
Certificate of Accreditation: Supplement
AG Metrology S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 20 of 22
Thermodynamic MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Digital thermometer used
with RTD and themistor F
-80 °C to 150 °C 0.038 °C Fluke 7380
Additel 875-155
Additel 875-660
SPRT Rosemount 162CE
PRT Fluke 5628
Datron 1271
Fluke 1590
ASTM E644
ASTM E2877
150 °C to 420 °C 0.11 °C
420 °C to 600 °C 0.24 °C
Digital thermometer used
with RTD and thermistorO
-40 °C to 150 °C
0.14 °C
Additel 875-155
Additel 875-660
SPRT Rosemount 162CE
PRT Fluke 5628
Agilent 34970A
ASTM E644
ASTM E2877
150 °C to 420 °C 0.20 °C
420 °C to 600 °C 0.31 °C
Thermometer InfraredFO 150 °C to 420 °C 1.2 °C IR-463 blackbody
Thermocouple type S
ASTM E1256
ASTM E2847
420 °C to 600 °C 1.4 °C
600 °C to 1 050 °C 2.3 °C
Temperature: Dew point
hygrometerFO
-20°C to 40°C 0.19 °C
General Eastern Optica
General Eastern D2
General Eastern SIM-12H
General Eastern C1 RH
ASTM D4230
Temperature: measuring of
temperature environmental
conditions in airFO
10°C to 40°C 0.16 °C
Resistance thermometer
General Eastern C1 RH
Agilent 34970A
CEM TH - 007
Temperature: controlled
temperature enclosures FO
-80°C to 150°C 0.21 °C Resistance thermometer
Thermocouple N
Agilent 34970A
Euramet Calibration
Guide No. 13
Euramet Calibration
Guide No. 20
AMS 2750
CQI-9
IEC 60068-3-11
150°C to 420°C 0.63 °C
420°C to 600°C 1.2 °C
600°C to 1050°C 2.9 °C
1050°C to 1300°C 3.8 °C
Relative humidity:
measuring of relative
humidity environmental
conditions in airFO
10% RH to 90% RH From 0.50 % UR to 1.6 % RH
General Eastern Optica
General Eastern D2
General Eastern Sim 12H
General Eastern C1 RH
DKD-R 5-8
CEM TH - 007
Certificate of Accreditation: Supplement
AG Metrology S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 21 of 22
Thermodynamic
1. The CMC (Calibration and Measurement Capability) stated or calibrations included on this scope of
accreditation represents the smallest measurement uncertainty attainable by the laboratory when performing
a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is typically
expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual
measurement uncertainty associated with a specific calibration performed by the laboratory will typically
be larger than the CMC Or the same calibration since capability and performance of the device being
calibrated and the conditions related to the calibration may reasonably be expected to deviate ideal to some
degree.
2. The laboratories range of calibration capability or all disciplines or which they are accredited is the interval
the smallest calibrated standard to the largest calibrated standard used in performing the calibration. The
low end of this range must be an attainable value or which the laboratory has or has access to the standard
referenced. Verification of an indicated value of zero in the absence of a standard is common practice in the
procedure or many calibrations but by its definition it does not constitute calibration of zero capacity.
3. The presence of a superscript F means that the laboratory performs calibration of the indicated parameter at
its fixed location. Example: Outside MicrometerF would mean that the laboratory performs this calibration
at its fixed location.
4. The presence of a superscript O means that the laboratory performs calibration of the indicated parameter
onsite at customer locations. Example: Outside MicrometerO would mean that the laboratory performs this
calibration onsite at the customer’s location.
5. The presence of a superscript FO means that the laboratory performs calibration of the indicated parameter
both at its fixed location and onsite at customer locations. Example: Outside MicrometerFO would mean
that the laboratory performs this calibration at its fixed location and onsite at customer locations.
6. Measurement uncertainties obtained or calibrations performed at customer sites can be expected to be
larger than the measurement uncertainties obtained at the laboratories fixed location or similar calibrations.
This is due to the effects of transportation of the standards and equipment and upon environmental
conditions at the customer site which are typically not controlled as closely as at the laboratories fixed
location.
MEASURED INSTRUMENT,
QUANTITY OR GAUGE
RANGE OR NOMINAL
DEVICE SIZE AS
APPROPRIATE
CALIBRATION AND
MEASUREMENT CAPABILITY
EXPRESSED AS AN UNCERTAINTY
(±)
CALIBRATION
EQUIPMENT
AND REFERENCE
STANDARDS USED
Relative humidity:
controlled humidity
enclosuresFO
10% RH to 90% RH 3.2 % RH
General Eastern Optica
General Eastern D2
General Eastern Sim 12H
Resistance thermometer
Agilent 34970A
Euramet Calibration
Guide N. 20
IEC 60068-3-11
Certificate of Accreditation: Supplement
AG Metrology® S.r.l Strada San Faustino, 155 N, 41124, Modena (MO), Italy
Dr. Giorgia Calzolari Phone: +39 059 3970648
Accreditation is granted to the facility to perform the following calibrations:
Issue: 5/2020 This supplement is in conjunction with certificate #L20-291-R1 Page 22 of 22
7. The term D represents diameter in inches or millimeters as appropriate to the uncertainty statement.
8. The term DL represents diagonal length in inches or millimeters as appropriate to the uncertainty statement.
Note that Diameter and Diagonal both use the same designation “D”. This is not a problem unless a laboratory is
accredited or both however the usage is common and should be retained when possible and modified in the few
cases where a laboratory is accredited or both. In those cases continue to use D Or diameter and use DL Or
Diagonal Length. This note is intended or internal office use only and is to be removed during preparation of draft
documents.
9. The term L represents length in inches or millimeters as appropriate to the uncertainty statement.
10. The term P represents pressure in units appropriate to the uncertainty statement.
11. The term R represents radius in inches or millimeters as appropriate to the uncertainty statement.
12. The term T represents temperature in ºC or ºF as appropriate to the uncertainty statement.
13. The term T represents torque in N•m (including SI multiple and submultiple units) Or the international
system of units (the SI) or ozf•in, lbf•in and lbf•ft Or the USC system of units.
Note that temperature and torque both use the same designation “T”. This is not a problem unless a laboratory is
accredited or both however the usage is common and should be retained when possible and modified in the few
cases where a laboratory is accredited or both. In those cases continue to use T Or temperature and use Tr Or
torque. This note is intended or internal office use only and is to be removed during preparation of draft documents.
14. The term Wt represents weight in pounds or grams (including SI multiple and submultiple units)
appropriate to the uncertainty statement.
15. The term “X” proceeded by a number represents the number of times a lens system magnifies an image
relative to its actual size. CMC stated as “% of magnification” represents the CMC of magnification
expressed as a percentage of the total magnification.
16. The C represents concentration in moles or micromoles appropriate to the uncertainty statement.