WHO WE ARE
INDEX
CONTACT US
WJF Instrumentation Ltd.#5, 3610 -29th Street N.E.Calgary, AB T1Y 5Z7Phone: (403)291-5570Toll-Free: (877)291-5572Fax: (403)291-3714Email: info@wjf.caWeb: www.wjf.ca
WJF Instrumentation Ltd., is an instrumentation supply company based in Calgary, Alberta, Canada. Since 1984we have been offering the highest quality instrumentation to virtually every industry in Western Canada.
WJF’s sales staff and service technicians offer timely quotes and dependable service to our valued customers.Please call us at (403)291-5570 or toll-free (877)291-5572 for immediate and personal assistance.Let us know if there is a measurement problem we can help you with!
Clicking on any of the images will take you to the relevant .pdf document for that image.
TURBIDITY AND DISINFECTANTS
MULTI-PARAMETER ANALYZERS, DISSOLVED OXYGEN,FLUORIDE, UV% TRANSMITTANCE, STREAMINGCURRENT
pH, ORP, CONDUCTIVITY, FLOWMETERS
AUTOMATIC SAMPLERS, CHEMICAL FEEDPUMPS, REAGENTS, STANDARDS, BUFFERS
SOLENOID VALVES, PROCESS VALVES, METERS
LEVEL, CALIBRATION GAS
SENSORS, AUTODIALERS, TEMPERATURE
GAS & FIRE DETECTION, PRESSURE PAGE 8
PAGE 1
PAGE 2
PAGE 3
PAGE 4
PAGE 5
PAGE 6
PAGE 7
SWAN’s AMI Turbiwell LED on-line turbiditym o n i t o r i s E PA 1 8 0 . 1 c o m p l i a n t .The non-contact optics utilize a long-lifeLED light source and require no calibration!This instrument is ideal for potable water,raw water, and filtered water in watertreatment plants. More details on thisproduc t wi l l be avai lable on ourweb site at http://www.wjf.ca, andin the on-line version of this catalogue.
DEWPOINT, CEMS, FIBERGLASS PAGE 9
WATER TREATMENT
ANALYZERS, MONITORS, TRANSMITTERS
Disinfectants
Turbidity• Non-Contact
Never Requires Calibration!EPA Approved White Light LED
• Stable Light Source Lasts IndefinitelyNo Optics Cleaning Required
• Never Buy Standards Again• Fast, Easy Verification (twice yearly)
OPTIONS:
Degasser for < 1 NTU RangeAutomated Sedimentation Drain ValveFlowmeter for Clean LiquidsVerification Kit for Low and High NTU
• Remote Sensor from Transmitter• Profibus, Modbus, 3rd 4-20mA, RS-232
••
•
• Unbelievably Low Maintenance• All Components Mounted on PVC Panel• 0.000 up to 200.0 NTU Range
••••
On-Line Turbidimeter
SWAN AMI Turbiwell LED
HF Scientific MicroTOL
• Low-Cost• 0.000 up to 1000 NTU Ranges• Built-In Flow Control and Shutoff Valves• Bubble Rejection System• Optics Isolated from Sample by Cuvet• Easy Maintenance• Compact Instrument
On-Line Turbidity Monitor
•
•
•
OPTIONS:
• Amperometric 3-Electrode System• Very Stable (< 1% Drift per Month)• Uses NO Consumables
Long Sensor Life, 5 to 10 Years• Flow Monitoring & Flow Control• Also Ozone, ClO2, Bromine, Iodine
Fast, Easy Maintenance & Calibration
• pH Monitoring & Compensation• Profibus, Modbus, 3rd 4-20mA,RS-232
Free Residual Chlorine Monitor
SWAN AMI Trides
SWAN AMI Codes-II
•
•
OPTIONS:
• Colorimetric Absolute Method• No Calibration Required• Unique Flow Injection SystemExtends Maintenance Intervals
• Flow and Reagent Level Monitoring• Also Measures Monochloramines,Ozone, ClO2, Bromine, Iodine, MNnO4Simple Maintenance
• pH & Temperature Monitoring• Cleaning Module for Dirty Samples• Profibus, Modbus, 3rd 4-20mA,RS-232
Free Residual Chlorine Monitor
•
•
OPTIONS:
Monitors
and more• Ideally Suited for Monochloramination• Colorimetric Absolute Method• No Calibration Required• Unique Flow Injection System• Flow and Reagent Level Monitoring
Simple Maintenance
• pH & Temperature Monitoring• Cleaning Module for Dirty Samples• Profibus, Modbus, 3rd 4-20mA,RS-232
Free Chlorine, Total Chlorine,Monochloramines, Combined Chlorine
SWAN AMI Codes-II CC
HF Scientific CLX
•
• Colorimetric Method• Compact, Easy to Use System• Low Water Usage (~ 9 LPH)
Free & Total ResidualChlorine Monitor
• For Use with AMI Codes Monitors• 2 Chemicals Extend Maintenance Intervals
SWAN Cleaning Module-II
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
1
High purity water turbidity
monitors are also available
Simple Verification of theSWAN AMI Turbiwell LED
WATER TREATMENT
ANALYZERS, MONITORS, TRANSMITTERS
Dissolved Oxygen
Multi-Parameter
•
•
•
Multi-Paramater• Measures Up to 3 Parameters Simultaneously• Stream Switching for up to 6 Sample Streams
ISE, Colorimetric, & Titration Methodologies• Automatic Calibration• Unique Modular System for Customization• Low Reagent Usage (0.5 to 1mL per analysis)• Many I/O Options with Trending & Graphing• Available with CSA Class I Div. 2 Approval
Many Parameters Available Including:Ammonia, Nitrate, Phosphate, Fluoride,Calcium, Chloride, Chromium, Copper,Cyanide, Hardness (Calcium and Magnesium),Iron, Potassium, Sodium, Sulfate, Sulfide,and Many More
Process Liquids Analyzer
Applikon Model ADI2040
• Single-Parameter• Same Parameters Available as the ADI2040•• Proven Rugged Process Analyzers• Complete Field Technical Support from WJF
ISE, Colorimetric, & Titration Methodologies
Process Liquids Analyzer
• PPM Range• Flow-Through or Remote Sensor Types• Reliable, Proven Clark Type Sensor• Automatic Calibration Procedure• Membrane and Electrolyte Monitoring• 0 to 20 ppm up to 0 to 200% Saturation
WALL MOUNT• Flow-Through Sample Chamber• Optional Needle Valve and Flowmeter
REMOTE SENSOR• Self-Cleaning Option for Open Basins or Tanks• PVC Probe Holders with or without Cleaning• Fixed Holder or Pendulum Type Holder• Cleaning with Water or Solution Tank
Dissolved Oxygen Monitor
SWAN FAM Oxysafe
HF ScientificAccUView
•
•
On-Line• Models for Water or Wastewater• Easy to Use, Simple Maintenance• Flow Shutoff and Control Valve• Ultrasonic Optical Cleaning• User Selectable Update Times• Bubble Rejection System• Measures at 253.7nm
WASTEWATER VERSION INCLUDES:
• Bellows Pump for Sample Flow• Power Supply
NEMA 4X Stainless Steel Enclosure• Foot Strainer and T-Strainer
UV% Transmittance Monitors
• Economical On-Line• Potentiometric Measurement• Accuracy Within +/- 10%• Not to be used for Fluoride Control• Automatic Temperature Compensation• Optional Flow Control and Metering• Range from 0.01 to 1000 ppm• Mounted on Panel and Ready to Go
Fluoride Monitor
• On-Line• for Coagulant Addition Monitoring
• Calibrated to a Known Ion Charge UnitUsing a Cationic Polymer Solution
• Remote Display• Graphical Trending (8 or 24 hr.)
Streaming Current Monitor
HF ScientificAccuview Wastewater
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
2
Contact us for a detailed
list of PARAMETERS and
Application Data Sheets
Applikon Alert
Applikon ADI 2016/2018/2019
• Single-Parameter Lower Cost• Designed for Municipal Applications• Also suitable for Utilities Applications• Ion Selective and Colorimetric Methods• Sample Sequencing Possible in Some Cases• Polypropylene IP55 Enclosure
Liquids Analyzer
For Submersible
Applications
Fluoride
SWAN FAM Fluoride
Applikon ISE analyzers can
ALSO measure Fluoride with
High Accuracy
UV% Transmittance Streaming Current
HF Scientific MicroTSCM
Flowmeters
Burkert Type 8041
withType S020 PVC
Flow Fitting
Blind InsertionMagmeter
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
All are Available with
Wall-Mount electronics
Kobold Variable Area Flowmeters
WATER TREATMENT
ANALYZERS, MONITORS, TRANSMITTERS3
Burkert Type 8045
Mounted in Type S020PVC Flow Fitting
Insertion Magmeter
Burkert Type 8025
with Type S020Saddle Fitting
Insertion PaddlewheelFlowmeter
Burkert Type 8035
with316 SS Fitting
Inline PaddlewheelFlowmeter
Burkert Type 8050
withRemote Display
Full-Bore MagneticFlowmeter
• Plastic or Glass Tube• Variety of Fitting Types• Integral Switches, Needle Valves• Low Cost and High Precision• Micro to High Volume Flows• For Air or Liquids
• Burkert Flowmeters Include Teach-In Function for Easy Calibration • 2 Totalizers • Analog & Pulse Outputs• Fittings Available in PVC, PVDF, Brass, Stainless Steel, and More • Insertion or Inline Fittings Available• For Line Sizes from ½”up to 16” in Diameter • NPT, Flanged, Weld-End, Sanitary Type Fittings Available
Wall-Mount Electronics Available for All Types • Menu Driven Interface Easy to Operate and Set Up• •
pH, ORP (Redox), Conductivity
Walchem
• Multi-Purpose• 4-20mA, Pulse, Powered Relay Options
• Standard or Differential pH Sensors• Contact or Non-Contact Conductivity Sensors
• Excellent for Acid/Base/Chemical Control• USB Stick Data Collection
pH/ORP and Conductivity Controllers
Knick Stratos
• Industrial Grade Controllers• Wall-Mount or Panel Mount
• Available with CSA for Class I Div. 1• Sensor Monitoring
• 3-Year Warranty
pH/ORP/Conductivity Controllers
Burkert ELEMENT 8202 for
• Compact, All-In-One System• Dot Matrix Backlit Display• Two Transistor Outputs• 1 or 2 x 4-20mA Outputs• Fast Install and Maintenance• Many Sensor Options• Insertion Fittings Make it Easy
pH/ORP
Burkert ELEMENT 8222 for
• Compact, All-In-One System
• 2-Electrode Cell with Temp. Comp.• Two Transistor Outputs• 1 or 2 x 4-20mA Outputs• Fast Install and Maintenance• Insertion Fittings Make it Easy• 0.05 µS up to 10 mS/cm Range
• Dot Matrix Backlit Display
Conductivity
SWAN AMI
• Wall-Mount Flow Through Type• Optional Flow Monitoring• Optional Flow Control Valve• Includes Pt1000 Temp. Sensor• All Mounted on PVC Panel• Factory Tested, Ready for Operation
pH/Redox Monitor
SWAN AMI Solicon 4
• Wall-Mount Flow Through Type• Optional Flow Monitoring• Optional Flow Control Valve• From 0.1µS to 100 mS Range• All Mounted on PVC Panel• Guides User Through Maintenance• Calibration without Sensor Removal• Factory Tested, Ready for Operation
Conductivity Monitor
Chemical Feed Pumps
Automatic Samplers
Sirco BVS 4300
• Heavy Gauge or Stainless Steel Enclosure• Optional Insulation & Forced Air Heater
• Locking Door and Bolt-Down Holes• Pull-Out Tray for Easy Service
Outdoor Sampler
The most reliable and easy-to-use
samplers on the market today!
Sirco CVS 4200
• Our Top Selling Sampler• Optional Glass Door Fridge
Indoor Sampler
•
HF Scientific Powder Pop
Eliminate the Muss and Fuss of DPD Testing• Keeps the Chemical Off of Your Hands• Simple Push-Button Operation• Works with All DPD Testers (5, 10, 25mL)• Highly Reliabile Disposable Dispensers
DPD Dispensers
Walchem EHE Series
• Up to 360 spm High Resolution Feed
• Turndown Ratio of 1800:1• Versatile Control Features
• Very Long Service Life• 2-Year Warranty
• Primes Fast and Holds Prime!
• Dual Bearing Support• Dual Check Valve Assembly• Digital Display and 4-Button Keypad• Flow Rates up to 20 gph• Pressures up to 150 psi
WATER TREATMENT
SAMPLERS, PUMPS, REAGENTS4
Sirco 4120
• The Lightest Sampler at 23 Pounds• Easy to Use Controller, Simple!• Tough Polyethylene Enclosure
• Optional Stainless Steel Harness• Lockable
Portable Sampler
Walchem E Series
• p to 360 spm High Resolution Feed
• Turndown Ratio of 1800:1• Versatile Control Features
• Very Long Service Life
W
U• Primes Fast and Holds Prime!
• Dual Bearing Support• Dual Check Valve Assembly• Digital Display and 4-Button Keypad• Flow Rates up to 6.7 gph• Pressures up to 250 psi
• Optional Feed Verification (shown)• 2-Year Warranty
Walchem E Series
•
p to 360 spm High Resolution Feed• Turndown Ratio of 0:1
• Very Long Service Life
Z
Low-Cost High Performance Pump• Primes Fast and Holds Prime!• U
36• Dual Bearing Support• Dual Check Valve Assembly• Digital Display and 4-Button Keypad• Flow Rates up to 6.3 gph• Pressures up to 150 psi• Timer Control Module Option
• 2-Year Warranty
FMI Chloritrol
Eliminates Pump Head Lockup inSodium and Calcium Hypo Injection
• Dual Head Design to Remove Gas inthe Pump Head
• Valveless Low Maintenance DesignPrimes Against 125 psi Pressure
• Accurate, Drift Free Operation• Optional 4-20mA Controller• Flow Rates up to 18 gph
•
•
HypochloriteInjection System
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
Reagents, Standards and Buffers
•
HF Scientific Procal
Next-Generation Non-Toxic Standards• EPA Approved & Made for Hach 1720’s• Plastic Bead Polymer Suspension• 2-Year Shelf Life (from manufacture)• All Standard Ranges and Custom Too• Competitive Pricing!
Turbidity Standards
Calibration Columns Available Too
ALSO:
•••• Many More...
pH BuffersISE StandardsEC Standards
Sirco
• Most Reliable and Easiest to Use on the Market• Fast and Powerful Vacuum Pump System• Lifts Sample up to 25 Feet at 4 ft/sec
r up to 100 Feet Horizontal at 5 ft/sec• Best for BOD - No Tubing Contamination
Easy to Clean Metering Chamber
• Three Year Warranty• Built in Canada
• No Peristaltic Tubing to Change Out• Refrigerated or Non-Refrigerated• Highly Repeatable Samples
Automatic Wastewater Samplers
o
and
Process Valves
Solenoid Valves
Burkert Type 6213
• ¼” NPT up to 2” NPT Sizes• Brass or 316 Stainless Steel Body• Direct Acting, 0 to140 psi Range• For Cold & Hot Water• Optional LED Indicators
Solenoid Valve
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
We have plastic valves too.
WATER TREATMENT
VALVES, METERS5
Burkert 2100On/Off Type
Angle-Seat Valve
Hanna HI 9125N
• Large Dual-Level LCD DisplayScreen• Includes pH and Temperature Sensors• Waterproof• Includes Many Accessories Such AsCarrying Case, Inductive Recharger, pHBuffers, Power Adapter
pH/mV/ ORP/Temp. Meter
Burkert Type 5282
• Unique Pivot Armature Design• Good for More Aggressive Media• ½” NPT up to 2” NPT Sizes• Brass or 316 Stainless Steel Body• 2.8 to 140 psi Range• Optional LED Indicators
Solenoid Valve Burkert Type 1078
• Perfect for Automatic Drainingof Compressed Air Systems
• Plug-On Programmable Timer• Use with Most Burkert Valves• Digital or DIP Switch Versions• Easy Setup
Timer Unit
Burkert Type 6014 Pilot
• 3-Way, ¼” NPT Piloting Solenoid Valve• Brass or 316 Stainless Steel Body• For Piloting Air-Actuated On/Off Valves• Banjo (direct-mount) Versions Available
Solenoid ValveBurkert
• Modular System with Multiple Valves• Compact, Easy to Connect Systems• High Flow Rates, Highly Reliable• Available with Analog and Digital I/O
Valve Actuation Modules
< ON/OFF
Reliable, Air Actuated Process ValvesBrass, Stainless, and Plastic Body MaterialsFrom 3/8” up to 2.5” Body Sizes
• NPT, Flanged, Weld-End, Tri-Clamp Fittings• Optional Feedback Switch, Stroke Limiters,Manual Override
•••
CONTROL >
Powerful Controller Built Into the HeadFast-Acting with Internal Feedback
• Positioning Valve or Internal PIDDirect Sensor Inputs (PT100, Flow, level)
• Digital Display, Keypad, and Menu System• Easy Setup will Autotune Functions
••
•
Burkert 2103On/Off Type
Diaphragm Valve
Burkert 2101On/Off TypeGlobe Valve
Burkert 8802-YGControl Type
Angle-Seat Valve
Burkert 8802-DFControl Type
Diaphragm Valve
Burkert 8802-GDControl TypeGlobe Valve
Meters
Hanna HI 98703
• EPA Compliant Tungsten Light Source• Range from 0.00 up to 1000 NTU• Optional Logging Multi-Location Tags• Light Source Drift Compensation• Accessories Include: 5 Sample Cuvets,Batteries, AC Adapter, Quality Cert.Manual, Rigid Carrying Case
Turbidity Meter
Hanna HI 3222
• Bench Top Meter for Several Parameters• Calibration Check Diagnostics System• Up to 5 Point Calibration w/ up to 7 Buffers• 2 Input Channels (e.g. pH and Fluoride)• Graphic Backlit LCD• Log on Demand for up to 400 Sampleswith USB Connection to PC
• Auto HOLD to Freeze Readings on Screen• Calibration Reminders• Includes pH & Temperature Electrodes,pH Buffers, Cleaning Solution, ElectrolyteSolution, Power Adapter, Instructions
pH/mV/ISE Temp. Meter
Hanna HI 991300
• Large LCD Display Screen
• Easy 2 Button Operation withTutorial Messages for Operationand Setup
• Single-Multi-Parameter Probe
• Waterproof
pH/EC/TDS Meter
Hanna HI
•
•• Single-Multi-Parameter Probe
9828
pH, EC/TDS, ORP, D.O. AtmosphericPressure and Temperature
• Menu Driven NavigationFull Configuration of Each Parameter
• Lots of Accessories IncludingSoftware, Case, Probe Maintenance Kit
Multiparameter Meter
WATER TREATMENT
LEVEL AND CALIBRATION EQUIPMENT
Level
Burkert 8137
• Accurate Non-ContactLevel Measurement
Radar LevelTransmitter
ACD Cal2000 Gas Generator
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
6
B/W Controls 6012/6013• Use with B/W Control Relays (to left)
Level Sensors
Calibration (gas)
Burkert 8185
Good for PenetratingFoam on Liquids
Guided WaveRadar LevelTransmitter
•
Burkert 8181Horizontal Float
Level Switch
Burkert 8326
Great for OpenAir/Vented Tanks
Pressure/LevelTransmitter
•
Kobold NTB
Extra LongCables Available
Deep WellLevel Probe•
B/W Controls 5400 Series Control Relays
B/W Controls 5200 Series Control Relays
Burkert 8176
Economical LevelMeasurement
UltrasonicLevel
Transmitter•
B/W Controls7330 Pro-Stik II
Suitable for CleanLiquids, Even Diesel
Fuel, etc.
Float LevelTransmitter
•
Ametek B/W Controls Level Controls
• Excellent for Municipal Applications• Simple, Reliable Systems for Tanks, Reservoirs,Lift Stations, Pump Up/Down Control and More
• Many Types of Electrodes, Holders, Control Relays• Compatible Materials for All Liquid Types
• Hi/Low Control, Multi-Point, & Continuous Level• Custom Configurations for Any Level Requirement
• Proven, Economical and Reliable Solutions
•
•
•
The Best Pricing in the Industry!• H2S, CO, O2, LEL, Cl2, SO2, NH3, Many More...
17, 34, 58, 76, 103, and 116 Litre Cylinders• Refillable Cylinders Available
Regulators, Carrying Cases, Tubing, etc.
We also supply Bump-Test Stations
and Bump-Test Gas Generators
Burkert 8111
Vertical orHorizontalMounting
Tuning ForkLevel Switch•
WJF Calibration Gas Cylinders
•
•
•
Available for Cl2, H2S, ClO2,• Adjustable Concentration and Flow Rate
50 Hours of Calibration Gas Per Cell• Digital Display, Easy to Use Device
Eliminate Shelf-Life Concerns with Cylinders
Every level application has its challenges. Please consult us for the best solution for your application!
Autodialers & SCADA
Sensors Van London pHoenix Company<
• Aftermarket Sensors for Perfect Retrofit• Plastic, Glass, Ceramic Bodies
• The Latest Measuring Advancessuch as the new GX-V Glass for pH
• Plenty of Junction Options• Most Connector Styles
• We Have Many Sensors in Stock!
Laboratory pH, ORP, ISE, Conductivity Sensors
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
WATER TREATMENT
SENSORS, AUTODIALERS, TEMPERATURE7
Walchem WebMaster
• Monitors• Controls• Alarms
• Datalogs• Reports
Burkert 8400
• Easy to Use with Extra-Large LCD Display• Use as a Switch or Add Transmitter Function• Compact (local) or Wall-Mount Versions• Screw-In ½” NPT Fitting• 29.5mm, 100mm, and 200mm Lengths
Temperature Transmitter/Switch
Walchem WebAlert
• Monitors• Alarms
• Datalogs• Reports
Temperature
Burkert ST21 Screw-In
• Pt 100 Sensor• With or Without 4-20mA 2-Wire Transmitter• Wide Measuring Range -58F to 302F• 316 Ti Sensor• Lengths from 3.93” up to 20.07”
Temperature Sensors
Burkert TST001 Compact
Pt 100 Sensors• Stainless Steel (1.4571)• 3m Cable with Teflon Coated Cable
Optional Cable PlugTie into Wall-Mount 8024 Switch
• IP65 Protection
•
••
Temperature Sensors
>
• Tough, Rugged Sensors that Exceed OEM Quality• Most Styles for Most Manufacturers (Rosemount,
Yokogawa, E&H, TBI, and Many More)• Sensor Holders and Wet-Tap Assemblies
• Integrated Temperature Sensors• Many Connector and Cable Types
• Low-Cost Options Available
Process pH, ORP, D.O., Conductivity Sensors
RACO
• Autodialers to Full PLC Communication & Backup• Voice Dialing, Text Messaging, Reporting etc.
• Rugged Industrial Products• Perfect for Water Treatment Plants
Autodialers & SCADABurkert Type 8619
• Multi-Channel Transmitter/Controller• 2 x Analog, 2 x Digital Outputs
& 2 x Digital Inputs, and More• Backlit LC Graphic Display
• Datalogger for up to 16 Values
Multi-Function Controller
Gas & Fire Detection
Scott 6000 SeriesUniversal Toxic Gas
Transmitter
Scott Freedom 5000Series 2-Wire UniversalToxic Gas Transmitter
Scott 4600 SeriesUniversal 2, 3 or 4-WireToxic Gas Transmitters
Scott 7200/7400• 1 or 2-Channel & 4-Channel Controller
• Transmitter & Direct Sensor Inputs
Scott 7800 Sentinel 16•16-Channel Receiver,
• Wall, Panel, or Rack Mount• Plenty of I/O Options
Scott 4688-IRInfra-Red Combustible
Gas Transmitter
Scott 4888 NIC-IICatalytic Bead Combustible
Gas Transmitter
Scott FV-300 Flame Detector• 256 Pixel Array Spectrum
• Wide Field of View• Can LocatePosition of a Fire
in the Field of View
More Models of Transmitters
Receivers are Available
and
Contact Us for Customized Solutions for:• Lift Stations, Chlorine Rooms, WWTP’s, Dechlorination Areas
• Small, Medium, and Large Facilities
Chlorine, ClO2, Ozone,
Sulfur Dioxide, Ammonia,
Hydrogen Sulfide, Oxygen and More
WATER TREATMENT
GAS/FIRE DETECTION AND PRESSURE8
Pressure
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
CONTACT US:
Burkert 8326Pressure/Level
Transmitter
Burkert 8311Pressure Switch/
Transmitter
Burkert 8323Pressure Switch/
Transmitter
• Optional Large Display with Graph• High Accuracy (<= 0.15%)• 0-5.8 up to 0-580 psi Ranges• ½” NPT Fitting
• Large LCD Display• Switch and/or Transmitter• Compact (local) or Wall-Mount• Screw-In ½” NPT Fitting
• 30” Hg to 400 psi Transmitter• ½”NPT Fitting• Piezoresistive or Thin-Film Sensor• Available with Flush Diaphragm
Yes we have gauges too!
WJF Instrumentation Ltd.#5, 3610 - 29th Street N.E.Calgary, AB T1Y 5Z7CANADA
Telephone: (403)291-5570Toll-Free: (877)291-5572Fax: (403)291-3714
Email: info@wjf.caWeb: www.wjf.ca
CEMS, Opacity, Dust
Dewpoint
WJF Instrumentation Ltd. - #5, 3610 – 29th Street N.E. Calgary, AB T1Y 5Z7Telephone: (403)291-5570 Fax: (403)291-3714 Email: info@wjf.ca Web Site: www.wjf.caToll-Free: (877)291-5572
Delta Instruments Dewpoint Transmitters
• Advanced Aluminum Oxide Technology• Sensors Will Not “Drift Dry”• AutoCal Field Calibration Function• Easy Push-Button Operation• 2 or 3-Wire Configuration• With or Without Display• Fast Response• Ranges down to 120 Degrees C• Available in with CSA I.S. Approval(includes barrier)
Goyen-Tyco UltraCEM
Monitors up to 5 Channels (O2, Co, CO2, NOx, SO2)Extractive Monitoring TechnologyTotally Self-Contained Analyzer
• Separate Sample Conditioning Unit (Probe Box)• Indoor or Outdoor Field Mounting• Long-Life Detectors• Integral Reporting Software• EPA Compliant
•••
CEMS
Goyen-Tyco
AC Coupled Triboelectric or ISE MethodCharged Particles Impact the Sensing Element
• Continuous Monitoring of Process Plant Emissionsor Filter Media Leakage
• Very Sensitive, Wide Range of Particle SizesEasy Installation
••
•
Particulate & Broken Bag Monitors
Fiberglass Strongwell
• Fiberglass Grating (pultruded & molded)• Handrail and Kickplate
• Ladder and Cage Systems• Structural Shapes and Plate
• Paneling• Decking and Planking
• Bolts, Nuts• Building Panels
FRP Advantages:80% of the strength of steel20% of the weight of steelHighly corrosion resistant
Available with non-slip coatingLow electrical conductivity
Not affected by cold weatherEasy to fabricate with
Low life cycle costs
Fiberglass Resin Products (FRP)
PROCESS
DEWPOINT, CEMS, FIBERGLASS9
Delta Instruments AMTwith
DS-1200 Remote DisplayDewpoint Transmitter
Delta Instruments AMT-Ex I.S.with I.S. Barrier
and DS-1200 Remote DisplayDewpoint Transmitter
Delta InstrumentsSADPmini Dewpoint Portable
Dewpoint Meter
Delta InstrumentsSADPminiEx Portable
Dewpoint Hygrometer
Delta Instruments
••••••
PortableDewpoint Hydrometers
Compact DesignEasy OperationMenu Driven SoftwareBuilt-In Pressure CalculatorFast ResponseDesiccant Drydown for FastMeasurements
• Electronic Auto Calibration• Ranges down to --110 C• Optional Datalogging• Optional 4-20mA Output
Goyen-Opal
Double Pass TechnologyKeypad Calibration and Testing
• Dual Outputs and Alarms• Optional Oxygen Sensor Available• Air Blower Assemblies Available
••
Opacity/Dust Monitors
• EPA Certification
top related