common abis project review mom 11-12 aug 2011 update.ppt
Post on 23-Nov-2015
20 Views
Preview:
TRANSCRIPT
-
MOM LIST (1/6)
NoNotePICTargetRemark1Telkomsel request for Common Abis SOP or Business Process and Database Parameter Standardization. Note : Fallback scenario will be included on SOP NSN 15 Augt 2011 Detail on attachment 2Telkomsel and NSN to conduct socialisation Common Abis SOP or Bussiness Process in Region Tsel/NSN CW37 3Telkomsel found some inconsistency database parameter, eg MSTXPMAXCH. NSN will verify for standarization and optimization.
NSN 16 Augt 2011 Balinusra Sumalpua
Kalimantan Sumatera
Activity Pre and Post Rehoming
Activity Pre Rehoming
NoActivityStart TimePIC
1Log alarms and Dbase collection72 Hours PTENIC Team
2Download latest BTS SW From SBSC(Siemens) to BTS12 Hours PTENIC Team
3Download XML Dbase to BSC (Nokia) Using CM Editor12 Hours PTENIC Team
4Error Verification, NIC Engineer & Dbase Creator must fix the error :Major Verication :1. Checking Bport Parameter on BCF Object2. Verify Gena,Egena and GTRX3. BCSU & PCU Load Cheking11 Hours PTENIC Team & DB Planner
5Create all sites on GCS Tool10 Hours PTENIC Team
5Attach BTS SW to BCF Object10 Hours PTENIC Team
6Unlock All LAPD TRX Signalling and OMU9 Hours PTENIC Team
7Unlock All TRX and BTS Object9 Hours PTENIC Team
Activity Post Rehoming
NoActivityStart TimePIC
1Check All BTS Status (Verification with DT Team)15 Minutes PENIC Team
2Check Traffic (CS & PS) availability15 Minutes PENIC Team
3Check Alarm on all BTS's15 Minutes PENIC Team
4Create HW descrepancies Report30 Minutes PENIC Team
5Get parameter dumb From CM Editor30 Minutes PENIC Team
6Check Dbase Consistencies45 Minutes PENIC Team &PLO
7Create CR and Send to NIC team1 Hour PEPLO
8Execute CR1 Hour PENIC Team
Note :
PTE : Prior to Execution
PE : Post Execution
Chart Pre rehoming
Chart Post rehoming
Fallback Criteria
Fallback Decession Criterias :
NoItemsRemark
1Unable to make Basic Call ( MOC/MTC Call,MOC/MTC SMS, PDP Context) until 50% of Plan Batch implementation in one night
2Power Cut during cut over time on specific NE
3Tranmission down during cut over time on specific NE
4PM Decession with approval of Assigned Telkomsel Leader
5Time reaches fallback limit decession at 3:00 AM
Fallback Step by step
NoItemsRemark
1TCSM : Move Ater Connection to previous connectionOn Site
2BTS : Reconfigure Dbase BTSEP to previous configuration (if any)Remote From NIC
3BTS : Change physical connection to SBSCOn Site
4BTS : Activate BTS SW BR10Remote From NIC
5BTS : Basic Call
-
Parameter Inconsistency Check
Some CRs already released & executed regarding to parameter inconsistency check PLMN Permitted (current setting is 0) already executed on Sep 12, 2011
Standarize parameter already executed on Sep 14, 2011
BSC#Cells
FLOBAMORA55
MASUBUD3
MAUMERE2
RUTENG26
SUMBAWA2
Grand Total18
BSC
KOPANG
PANJITILAR3
PRAYA2
-
Parameter Inconsistency Check (1/3)
Some CRs already released & executed regarding to parameter inconsistency check
-
Parameter Inconsistency Check (2/3)
Standarize parameter waiting for approval to execute.
Managed ObjectparametersSTANDARD VALUECount of cells with discrepancies
A_BTSbtsIsHopping10
A_BTScallReestablishmentAllowed0575
A_BTScellBarQualify025
A_BTScellReselectHysteresis7191
A_BTScellReselectOffsetRANGE (0 < MACRO DCS; INDOOR DCS; INDOOR GSM
-
Parameter Inconsistency Check (3/3)
Standarize parameter HOC and POC MO waiting for approval to execute..
Managed ObjectparametersSTANDARD VALUECount of cells with discrepancies
A_HOCenableIntraHoDl0265
A_HOCenableIntraHoUl0265
A_HOCenableMsDistance0162
A_HOCenablePowerBudgetHo10
A_HOCenableSddchHandover00
A_HOCenableUmbrellaHo10
A_HOChoTLDlRxLevelRule : DL >= UL2
A_HOChoTLUlRxLevelRule : DL >= UL2
A_HOChoTQDlRxQual5152
A_HOChoTQUlRxQual5148
A_HOCminIntBetweenUnsuccHoAttempt10527
A_HOCintraHoLoRxLevLimAmrHr630
A_HOCintraHoLoRxQualLimAmr70
A_HOCintraHoUpRxLevLimAmrHr630
A_POCbsTxPwrMax014
A_POCbsTxPwrMin151
A_POCpcLowerThresholdsLevDLRxLevelRule : DL >= UL and Lower < Upper0
A_POCpcLowerThresholsLevULRxLevelRule : DL >= UL and Lower < Upper0
A_POCpcUpperThresholdsLevDLRxLevelRule : DL >= UL and Lower < Upper0
A_POCpcUpperThresholdsLevULRxLevelRule : DL >= UL and Lower < Upper0
A_POCbsTxPwrMax1x0006
-
Parameter Inconsistency Check (1/3)
Some CRs already released & executed regarding to parameter inconsistency check BSC parameter consistency already executed on Aug 23, 2011
BSCNAMEPARAMETERVALUEPRESET VALUEMODIFIABLENPT_value
FB_BAUBAU1DRX TIMER MAX03YES3
FB_JNPONTO1DRX TIMER MAX03YES3
FB_KENDARI1DRX TIMER MAX03YES3
FB_KENDARI2DRX TIMER MAX03YES3
FB_PALOPO1DRX TIMER MAX03YES3
FB_PALOPO2DRX TIMER MAX03YES3
FB_PARE1DRX TIMER MAX03YES3
FB_PATTIROSOMPA1DRX TIMER MAX03YES3
FB_PINRANG1DRX TIMER MAX03YES3
FB_PSRWAJO1DRX TIMER MAX03YES3
FB_RNTEPAO1DRX TIMER MAX03YES3
FB_SIDRAP1DRX TIMER MAX03YES3
FB_TOBIA1DRX TIMER MAX03YES3
FB_WONO1DRX TIMER MAX03YES3
FB-BONE2DRX TIMER MAX03YES3
-
Parameter Inconsistency Check (2/3)
Standarize parameter BTS MO CRF released for implementation, 15-Sep-11.
Managed ObjectparametersSTANDARD VALUECount of cells with discrepancies
A_BTSbtsIsHopping16
A_BTScallReestablishmentAllowed0578
A_BTScellBarQualify058
A_BTScellReselectHysteresis7222
A_BTScellReselectOffsetRANGE (0 < MACRO DCS; INDOOR DCS; INDOOR GSM
-
Parameter Inconsistency Check (3/3)
Standarize parameter HOC and POC MO waiting for approval to execute..
Standarize parameter ADCE MO waiting for approval to execute..
Managed ObjectparametersSTANDARD VALUECount of cells with discrepancies
A_HOCenableIntraHoDl01419
A_HOCenableIntraHoUl01419
A_HOCenableMsDistance01797
A_HOCenablePowerBudgetHo10
A_HOCenableSddchHandover00
A_HOCenableUmbrellaHo120
A_HOChoTLDlRxLevelRule : DL >= UL6
A_HOChoTLUlRxLevelRule : DL >= UL6
A_HOChoTQDlRxQual5538
A_HOChoTQUlRxQual5520
A_HOCminIntBetweenUnsuccHoAttempt106
A_HOCintraHoLoRxLevLimAmrHr630
A_HOCintraHoLoRxQualLimAmr70
A_HOCintraHoUpRxLevLimAmrHr630
A_POCbsTxPwrMax03
A_POCbsTxPwrMin150
A_POCpcLowerThresholdsLevDLRxLevelRule : DL >= UL and Lower < Upper0
A_POCpcLowerThresholsLevULRxLevelRule : DL >= UL and Lower < Upper0
A_POCpcUpperThresholdsLevDLRxLevelRule : DL >= UL and Lower < Upper0
A_POCpcUpperThresholdsLevULRxLevelRule : DL >= UL and Lower < Upper0
A_POCbsTxPwrMax1x0001
Managed ObjectparametersSTANDARD VALUECount of cells with discrepancies
A_ADCEenableHoMarginLevQual10
A_ADCEadjCellLayer0412
A_ADCEdrThresholddrThreshold>rxLevMinCell3264
A_ADCEfastMovingThreshold035
A_ADCEhoLevelUmbrella6335
A_ADCErxLevMinCellrxLevMinCell
-
MOM LIST (2/6)
NoNotePICTargetRemark4Telkomsel found unproper EDAP abis mapping.NSN have done daily/weekly check on EDAP check and optimization. NSN send CR to Telkomsel (SQA Region) regarding EDAP Optimization
NSN ContinuousAlready do daily need to follow up for executionDetail on attachment (including GPRS configuration check)All areas
Balinusra Sumalpua
Kalimantan Sumatera
5NSN to propose E1 expansion on sites with lack of EDAP.NSN/Tsel-RAE 16 Augt 2011 Already included on attachment point No.4
-
GPRS & DAP Configuration Check
Some CRs already released & executed regarding to GPRS check CDED & CDEF (current setting is 100%) already executed on Aug 26, 2011
CDED & CDEF (enabling) already executed on Sep 14, 2011
BSC#Cells
KOPANG9
PRAYA21
Grand Total10
BSC #Cells
PANJITILAR33
PRAYA27
SUMBAWA2
Grand Total12
-
EDAP Tsl Configuration
need #extra ET1
Row LabelsCount of bsc_bcfid
BIMA13
KOPANG3
PANJITILAR317
PRAYA24
RUTENG212
SUMBAWA13
Grand Total62
Sheet2
Count of DAP TS Number
nameDAP TS NumberTotal
BIMA41
517
639
KOPANG21
318
432
51
64
PANJITILAR327
33
435
510
623
101
PRAYA2433
51
66
RUTENG221
32
47
520
616
SUMBAWA511
655
Grand Total344
Sheet2
1
17
39
1
18
32
1
4
7
3
35
10
23
1
33
1
6
1
2
7
20
16
11
55
344
Count of DAP TS Number Total
#EDAP Tsl Configuration
Sheet1
BSC_BCF_BTSNEIDaddressnamebscIdbcfIdbcf_namebcfTypedapIdfirstTsllastTslDAP TS NumbernseiType Of Coba
3606415BIM010GBALINUSRABIMA3606415AMBALAWIMGC7369242967417COBA2P8V2
3606416BIM010DBALINUSRABIMA3606416AMBALAWIMDC7273242967417unknown
36064111BIM011GBALINUSRABIMA36064111DONGGOMGC7371242967417M:COBA4P12V1
36064112BIM011DBALINUSRABIMA36064112DONGGOMDC7291242967417M:COBA4P12V1
36064113BIM011DBALINUSRABIMA36064113DONGGOMDC27275242967417M:COBA4P12V1
36064114BIM009GBALINUSRABIMA36064114LAMBUMGC7257253067417M:COBA4P12V1
36064115BIM009DBALINUSRABIMA36064115LAMBUMDC7290242967417M:COBA4P12V1
36064116BIM004GBALINUSRABIMA36064116MARIAMGC7259232867418COBA2P8V2
36064117BIM004DBALINUSRABIMA36064117MARIAMDC7292242967418unknown
36064118BIM021GBALINUSRABIMA36064118NCERAMGC7306252957418unknown
36064119BIM029GBALINUSRABIMA36064119PANDAMGC7260242967417M:COBA4P12V2
36064120BIM029DBALINUSRABIMA36064120PANDAMDC7340242967417M:COBA4P12V2
36064121MTR049GBALINUSRABIMA36064121PELSAPEMGC7370242967417F:ACOMCUV1
36064122MTR049DBALINUSRABIMA36064122PELSAPEMDC7274263057417M:COBA4P12V1
36064123BIM031GBALINUSRABIMA36064123SOROMANDIMGC7372252957417M:COBA4P12V1
36064124BIM031DBALINUSRABIMA36064124SOROMANDIMDC7337242967417unknown
36064125BIM100GBALINUSRABIMA36064125TELDORONAEMGC7305252957418M:COBA4P12V2
36064126BIM100DBALINUSRABIMA36064126TELDORONAEMDC7353253067418unknown
36064127SBW054GBALINUSRABIMA36064127TELDOROSBKMGC7258252957417M:COBA4P12V2
36064128SBW054DBALINUSRABIMA36064128TELDOROSBKMDC7338253067417unknown
36064129BIM101GBALINUSRABIMA36064129TELKOMSAPEMGC7374242967417unknown
36064130BIM101DBALINUSRABIMA36064130TELKOMSAPEMDC7339252957417unknown
36064131BIM018GBALINUSRABIMA36064131BIMAMGC7377252957418R:BS120V1
36064132BIM018DBALINUSRABIMA36064132BIMAMDC7358252957418R:BS120-2V2
36064133BIM020GBALINUSRABIMA36064133BIMAIIMGC7263252957418R:BS120V1
36064134BIM020DBALINUSRABIMA36064134BIMAIIMDC7344252957419R:BS120-2V2
36064135BIM014GBALINUSRABIMA36064135JATIWANGIMGC7324242967418COBA2P8V2
36064136BIM014DBALINUSRABIMA36064136JATIWANGIMDC7297253067419unknown
36064137BIM025GBALINUSRABIMA36064137MANGGEMACIMGC7332252957419M:COBA4P12V1
36064139BIM027GBALINUSRABIMA36064139NTOBOMGC7323242967419M:COBA4P12V1
36064140BIM057GBALINUSRABIMA36064140RABAMGC7379252957418COBA2P8V2
36064141BIM057DBALINUSRABIMA36064141RABAMDC7283252957419R:BS120-2V2
36064142BIM067GBALINUSRABIMA36064142RABAIIMGC7301252957419unknown
36064143BIM067DBALINUSRABIMA36064143RABAIIMDC7363252957418unknown
36064146BIM064GBALINUSRABIMA36064146TERMNLRABAMGC7310222767419R:BS120-2V2
36064147BIM064DBALINUSRABIMA36064147TERMNLRABAMDC7356232867418COBA2P8V2
36064148BIM008GBALINUSRABIMA36064148BELOMGC7375232867417M:COBA4P12V1
36064149BIM008DBALINUSRABIMA36064149BELOMDC7295242967419unknown
36064150BIM008DBALINUSRABIMA36064150BELOMDC37632253067419unknown
36064151BIM002GBALINUSRABIMA36064151MONTAMGC7307242967419COBA2P8V2
36064152BIM002DBALINUSRABIMA36064152MONTAMDC17354232867419M:COBA4P12V1
36064153BIM002DBALINUSRABIMA36064153MONTAMDC27294252847418M:COBA4P12V1
36064154BIM033GBALINUSRABIMA36064154PALIBELOMGC7321232867419M:COBA4P12V1
36064155BIM033DBALINUSRABIMA36064155PALIBELOMDC17342242967418M:COBA4P12V2
36064156BIM033DBALINUSRABIMA36064156PALIBELOMDC37278242967418M:COBA4P12V2
36064157BIM026GBALINUSRABIMA36064157RISAMGC7308263057418M:COBA4P12V1
36064158BIM026DBALINUSRABIMA36064158RISAMDC7355242967418unknown
36064159BIM001GBALINUSRABIMA36064159TENTEWOHAMGC7376252957418M:COBA4P12V1
36064160BIM001DBALINUSRABIMA36064160TENTEWOHAMDC17279232867418M:COBA4P12V1
36064161BIM001DBALINUSRABIMA36064161TENTEWOHAMDC27343242967418M:COBA4P12V1
36064164BIM009DBALINUSRABIMA36064164LAMBUMDC37633253067417M:COBA4P12V1
36064165BIM033DBALINUSRABIMA36064165PALIBELOMDC27631242967418M:COBA4P12V2
36064167SBW054DBALINUSRABIMA36064167TELDOROSBKMDC27652253067419unknown
36064168BIM023DBALINUSRABIMA36064168SADIAMD8300192467419M:COSA4P12V1
36064168BIM023DBALINUSRABIMA36064168SADIAMD8561192467419M:COSA4P12V1
36064169BIM025DBALINUSRABIMA36064169MANGGEMACIMD8347192467418unknown
36064170BIM024DBALINUSRABIMA36064170TAMBANAMD8360192467419M:COSA4P12V1
3606444MTR030GBALINUSRAKOPANG3606444AIKBUKAKMGC7281232647409COBA2P8V2
3606445SEL042GBALINUSRAKOPANG3606445AIKMELMGC7376252847410F:ACOMCUV1
3606446SEL042DBALINUSRAKOPANG3606446AIKMELDCSMDC7291242747410F:ACOMCUV1
3606447SEL083GBALINUSRAKOPANG3606447AIKMELUTARAMGC7308242637409M:COBA4P12V1
3606448SEL070GBALINUSRAKOPANG3606448BATUNAMPARMGC7283242747410COBA2P8V2
3606449PYA084GBALINUSRAKOPANG3606449BEBUAQMGC7307242637409M:COBA4P12V2
36064410SEL002GBALINUSRAKOPANG36064410BELANTINGMG8260192467409COBA2P8V2
36064411PYA015GBALINUSRAKOPANG36064411BELEKAMGC7329242527410unknown
36064412PYA009GBALINUSRAKOPANG36064412GANTIMGC7273252847410ACOMV6
36064413PYA007GBALINUSRAKOPANG36064413JANAPRIAMGC7257242857409COBA2P8V2
36064414SEL074GBALINUSRAKOPANG36064414JEROWARUMGC7321242747410M:COBA4P12V1
36064415MTR124GBALINUSRAKOPANG36064415JURITMGC7313242637409unknown
36064416SEL009GBALINUSRAKOPANG36064416KELAYUMG8332192467410COBA2P8V2
36064417SEL081GBALINUSRAKOPANG36064417KEMBANGSARIMGC7326242747410unknown
36064418MTR101GBALINUSRAKOPANG36064418KERUAKMGC7265242747409F:ACOMCUV1
36064419PYA050GBALINUSRAKOPANG36064419KOPANGMGC7276232537409R:BS120-2V2
36064420MTR039GBALINUSRAKOPANG36064420KORLEKOMGC7259242747410COBA2P8V2
36064421PYA016GBALINUSRAKOPANG36064421KOTARAJAMGC7327242637409unknown
36064422MTR104GBALINUSRAKOPANG36064422LABUHANHAJIMGC7263252847410R:BS120-2V2
36064423SEL015GBALINUSRAKOPANG36064423LENDANGNNGKMGC7268242747409ACOMV6
36064424SEL004GBALINUSRAKOPANG36064424LEPAKMGC7274252847410COBA2P8V2
36064425PYA037GBALINUSRAKOPANG36064425MANTANGMGC7377252737409R:BS120V1
36064426PYA001GBALINUSRAKOPANG36064426MANTANGIIMGC7372252737409R:BS120-2V2
36064427SEL013GBALINUSRAKOPANG36064427MASBAGIKMGC7374253067409R:BS120-2V2
36064428SEL064GBALINUSRAKOPANG36064428MONTONGGDNGMGC7312242637409unknown
36064429MTR073GBALINUSRAKOPANG36064429OTAKKOKOKMGC7264252737409F:ACOMCUV1
36064430SEL003GBALINUSRAKOPANG36064430PADAKMGC7333232647409COBA2P8V2
36064431MTR017GBALINUSRAKOPANG36064431PELKAYANGANMGC7275242637409COBA2P8V2
36064432MTR017DBALINUSRAKOPANG36064432PELKAYANGANMDC7290242747409M:COBA4P12V2
36064433SEL068GBALINUSRAKOPANG36064433PEMONGKONGMGC7323242747410unknown
36064434SEL050GBALINUSRAKOPANG36064434PENGADANGANMGC7315242637409unknown
36064435MTR018GBALINUSRAKOPANG36064435PESENGMGC7269242637409M:COBA4P12V2
36064436SEL043GBALINUSRAKOPANG36064436PRINGGABAYAMGC7262242747409R:BS120-2V2
36064437SEL072GBALINUSRAKOPANG36064437PRINGGASELAMGC7305242637409COBA2P8V2
36064438SEL010GBALINUSRAKOPANG36064438RENSINGMGC7371252847410COBA2P8V2
36064439SEL030GBALINUSRAKOPANG36064439RUMBUKIIMGC7328242747410unknown
36064440SEL056GBALINUSRAKOPANG36064440SAKRAMGC7370242747410F:ACOMCUV1
36064441MTR109GBALINUSRAKOPANG36064441SAMBELIAMGC7280252737409F:ACOMCUV1
36064443PYA083GBALINUSRAKOPANG36064443SELATPAMEPKMGC7310242637409unknown
36064444SEL006GBALINUSRAKOPANG36064444SELONGMGC7299252737410COBA2P8V2
36064445SEL006DBALINUSRAKOPANG36064445SELONGDCSMDC7289252847410F:ACOMCUV1
36064446PYA064GBALINUSRAKOPANG36064446SEMOYANGMGC7284242747410M:COBA2P8V3
36064447SEL086GBALINUSRAKOPANG36064447SEREWEMGC7324242747410unknown
36064448PYA054GBALINUSRAKOPANG36064448SETILINGMGC7285242637409ACOMV5
36064449SEL008GBALINUSRAKOPANG36064449SIKURMGC7379242747409COBA2P8V2
36064450SEL012GBALINUSRAKOPANG36064450SUELAMGC7380232647410COBA2P8V2
36064451MTR069GBALINUSRAKOPANG36064451SUKAMULIAMGC7278252847410F:ACOMCUV1
36064452SEL069GBALINUSRAKOPANG36064452SUKARAJAMGC7306242747410M:COBA4P12V2
36064453PYA086GBALINUSRAKOPANG36064453SURABYLEPAKMGC7311242747410unknown
36064454SEL005GBALINUSRAKOPANG36064454SURALAGAMGC7267232647410COBA2P8V2
36064455SEL034GBALINUSRAKOPANG36064455TANJUNGLUARMGC7369242747410F:ACOMCUV1
36064456MTR100GBALINUSRAKOPANG36064456TELBUKITBKNMGC7270242637409M:COBA4P12V2
36064457SEL071GBALINUSRAKOPANG36064457TELKOMSELNGMGC7286242747410M:COBA4P12V1
36064458SEL040GBALINUSRAKOPANG36064458TERARAMGC7375252847409F:ACOMCUV1
36064459MTR112GBALINUSRAKOPANG36064459WANASABAMGC7279252847410F:ACOMCUV1
36064460SEL075GBALINUSRAKOPANG36064460SELAPARANGMG8322192467409COBA2P8V2
2133274MTR120GBALINUSRAPANJITILAR32133274TANJUNGKARANGMG7587242857920unknown
2133276MTR097GBALINUSRAPANJITILAR32133276PANJITILARMG7578252847910F:ACOMCUV1
2133277MTR097DBALINUSRAPANJITILAR32133277PANJITILARMD7611242857905M:COBA4P12V1
2133278MTR055GBALINUSRAPANJITILAR32133278KEKERIMG7531242857917COBA2P8V2
2133279MTR002GBALINUSRAPANJITILAR32133279PAGESANGANMG7612252847910BS80V1
21332710MTR002DBALINUSRAPANJITILAR321332710PAGESANGANMD7563252847908M:COBA4P12V2
21332711MTR128GBALINUSRAPANJITILAR321332711SAPTAPESONAMG7583242857408unknown
21332712MTR029GBALINUSRAPANJITILAR321332712LINGSARMG7594252847909COBA2P8V2
21332713MTR033GBALINUSRAPANJITILAR321332713TELKOMSWETAMG7551242747909F:ACOMCUV1
21332714MTR001GBALINUSRAPANJITILAR321332714SELAGALASMG7552252847917BS80V1
21332715MTR130GBALINUSRAPANJITILAR321332715SEGANTENMG7595232867408unknown
21332716MTR038GBALINUSRAPANJITILAR321332716BTNSEGANTENGMG7520252847903COBA2P8V2
21332717MTR035GBALINUSRAPANJITILAR321332717RADIORIPERMG7542252847909BS80V1
21332718MTR006XBALINUSRAPANJITILAR321332718HTLGRANDLEGIID7614242527904COBA2P8V2
21332719MTR009GBALINUSRAPANJITILAR321332719JLSOEKARNOMG7526252847902SH:BS81SV2
21332720MTR701XBALINUSRAPANJITILAR321332720HTLOMBOKRAYAID7561252627918COBA2P8V2
21332721MTR185XBALINUSRAPANJITILAR321332721MATARAMMALLID7572252627912F:EMICRO-2V3
21332722MTR706GBALINUSRAPANJITILAR321332722PAGUTANMG7545242857408unknown
21332723MTR021GBALINUSRAPANJITILAR321332723KARTINI2MG7557252847902ACOMV5
21332724MTR021DBALINUSRAPANJITILAR321332724KARTINI2MD75741928107906M:COBA4P12V2
21332725MTR084GBALINUSRAPANJITILAR321332725DSANJANGKRIKMG7588242857917unknown
21332726MTR115GBALINUSRAPANJITILAR321332726AKARAKARMG7515252847405F:ACOMCUV1
21332727MTR065GBALINUSRAPANJITILAR321332727BAYANANYARMG7530232647405COBA2P8V2
21332728MTR042GBALINUSRAPANJITILAR321332728GANGGAMG7535232647406COBA2P8V2
21332729MTR014GBALINUSRAPANJITILAR321332729GILITRAWANGNMG7536242637904R:BS120-2V2
21332730MTR047GBALINUSRAPANJITILAR321332730KAYANGNLOMUTMG7915222767910M:COBA2P8V1
21332731NotDefiBALINUSRAPANJITILAR321332731MAGLINGMG7598242637901unknown
21332732MTR053GBALINUSRAPANJITILAR321332732PEMENANGMG7514242967406R:BS120-2V2
21332733SEL079GBALINUSRAPANJITILAR321332733SAJANUTARAMG7603242967407unknown
21332734SEL080GBALINUSRAPANJITILAR321332734SAMBIKELENMG7604242747408unknown
21332735MTR121GBALINUSRAPANJITILAR321332735SELENGANSEC12MG7600242747405unknown
21332736MTR121GBALINUSRAPANJITILAR321332736SELENGANSEC3MG7913242967405unknown
21332737SEL014GBALINUSRAPANJITILAR321332737SEMBALUNMG7529242747918F:ACOMCUV1
21332738SEL011GBALINUSRAPANJITILAR321332738SEMBALUNIIMG7529242747918COBA2P8V2
21332739SEL077GBALINUSRAPANJITILAR321332739SEMBALUNBUMBMG7589242967407unknown
21332740SEL078GBALINUSRAPANJITILAR321332740SEMBALUNSYNGMG7590242967407unknown
21332741MTR074GBALINUSRAPANJITILAR321332741SENDANGGILAMG7518242747405F:ACOMCUV1
21332742MTR704XBALINUSRAPANJITILAR321332742SHERATNSENGIID7615252627912M:COBA4P12V2
21332743MTR036GBALINUSRAPANJITILAR321332743TANJUNGMG7916242967406R:BS120-2V2
21332744MTR003GBALINUSRAPANJITILAR321332744AMPENANMG7541252847919F:ACOMCUV1
21332745MTR003DBALINUSRAPANJITILAR321332745AMPENANMD7568232867919ACOMV5
21332746MTR132GBALINUSRAPANJITILAR321332746ARUMJAYAMG7582242637911COBA2P8V2
21332747MTR025GBALINUSRAPANJITILAR321332747BDRSELAPARNGMG7558252847906unknown
21332748MTR703XBALINUSRAPANJITILAR321332748BDRSELAPARNGID7620232427910COBA2P8V2
21332749MTR067GBALINUSRAPANJITILAR321332749BUKITNIPAHMG7579252847406R:BS120-2V2
21332750MTR093GBALINUSRAPANJITILAR321332750GUNUNGSARIMG7525252847901ACOMV6
21332751MTR063GBALINUSRAPANJITILAR321332751HOLIDAYINNMG7546242747920R:BS120-2V2
21332752MTR702XBALINUSRAPANJITILAR321332752HTLJAYAKARTAID7567242527920COBA2P8V2
21332753MTR008GBALINUSRAPANJITILAR321332753KARTINIMG7524252847918BS80V1
21332754MTR129GBALINUSRAPANJITILAR321332754KEKALIKJAYAMG7584242857910unknown
21332755MTR031GBALINUSRAPANJITILAR321332755TELMATARAMMG7550252847919BS80V1
21332756MTR022GBALINUSRAPANJITILAR321332756LANGKOMTR3MG7556252847908R:BS120V1
21332757MTR022DBALINUSRAPANJITILAR321332757LANGKOMTR3MD7573252847919M:COBA4P12V1
21332758MTR024GBALINUSRAPANJITILAR321332758PELITAMTR4MG7577252847918ACOMV5
21332759MTR024DBALINUSRAPANJITILAR321332759PELITAMTR4MD7610242857918M:COBA4P12V2
21332760MTR031DBALINUSRAPANJITILAR321332760TELMATARAMMD7562252847919M:COBA4P12V2
21332761MTR051GBALINUSRAPANJITILAR321332761MONJOKBARATMG7599252957917COBA2P8V2
21332762MTR034GBALINUSRAPANJITILAR321332762NEWSENGGIGIMG7917232647920R:BS120V1
21332763MTR034DBALINUSRAPANJITILAR321332763NEWSENGGIGIMD7566252847920BS80V1
21332764MTR010GBALINUSRAPANJITILAR321332764SANDIKMG7555252847917R:BS120V1
21332765MTR041GBALINUSRAPANJITILAR321332765SENGGIGI2MG7540252847907COBA2P8V2
21332766MTR117GBALINUSRAPANJITILAR321332766BAGEKPOLAKMGC7580242967904unknown
21332767MTR106GBALINUSRAPANJITILAR321332767BANYUMULEKMGC7521253067902R:BS120-2V2
21332768MTR125GBALINUSRAPANJITILAR321332768BATUPUTIHMGC7906262947905unknown
21332769MTR125GBALINUSRAPANJITILAR321332769BATUPUTIHMGC37622282927905unknown
21332770MTR004GBALINUSRAPANJITILAR321332770DASANCERMENMGC7532242967903COBA2P8V2
21332771MTR019GBALINUSRAPANJITILAR321332771GAJAHMADAMGC7596253067908R:BS120V1
21332773MTR005GBALINUSRAPANJITILAR321332773GNPENGSONGMGC7553242967912COBA2P8V2
21332774MTR075GBALINUSRAPANJITILAR321332774KEBUNAYUMGC7908242747907COBA2P8V2
21332775MTR028GBALINUSRAPANJITILAR321332775KEDIRILMBKMGC7911252957901COBA2P8V2
21332776PYA008GBALINUSRAPANJITILAR321332776KURIPANMGC7907242967911ACOMV6
21332777MTR127GBALINUSRAPANJITILAR321332777LABUANTRENGMGC7605242967912unknown
21332778MTR187GBALINUSRAPANJITILAR321332778LABUHANPOHMGC7516242967905unknown
21332779MTR045GBALINUSRAPANJITILAR321332779PELLEMBARMGC7606242967901BS80V1
21332780MTR045DBALINUSRAPANJITILAR321332780PELLEMBARMDC7616253067906F:ACOMCUV1
21332781MTR098GBALINUSRAPANJITILAR321332781SEKOTONGBRTMGC7548253067903F:ACOMCUV1
21332782MTR040GBALINUSRAPANJITILAR321332782SEKOTONGTNGMGC7537253067908COBA2P8V2
21332783MTR131GBALINUSRAPANJITILAR321332783TAWUNMGC7910242967907COBA2P8V2
21332784MTR133GBALINUSRAPANJITILAR321332784GERUNGSLTNMGC7585242967911unknown
3606451PYA012GBALINUSRAPRAYA23606451PRAYAMG7372252957414unknown
3606452PYA012DBALINUSRAPRAYA23606452PRAYAMD7289242747413unknown
3606454PYA077GBALINUSRAPRAYA23606454SELONGBLANAKMG7283242747413unknown
3606455PYA077GBALINUSRAPRAYA23606455SELONGBLANAKMG37308242747413unknown
3606456PYA073GBALINUSRAPRAYA23606456BAGULOMTENGMGC7267242747414M:COBA4P12V1
3606457MTR078GBALINUSRAPRAYA23606457BAREJULATMGC7281242967414unknown
3606458PYA056GBALINUSRAPRAYA23606458BARELANTANMGC7265242747413COBA2P8V2
3606459PYA085GBALINUSRAPRAYA23606459BATUBEDUKMGC7268242747414unknown
36064510PYA010GBALINUSRAPRAYA236064510BATUNYALAMGC7374252847414SH:BS81SV2
36064511PYA059GBALINUSRAPRAYA236064511BERAIMMGC7376242967414COBA2P8V2
36064512PYA075GBALINUSRAPRAYA236064512BILBDRILOMMGC7269242747413unknown
36064513PYA072GBALINUSRAPRAYA236064513BONJERUKMGC7380242747414M:COBA4P12V2
36064514PYA071GBALINUSRAPRAYA236064514DAREKMGC7262242747414F:ACOMCUV1
36064515PYA088GBALINUSRAPRAYA236064515KABULXSONDMGC7305242747414unknown
36064516PYA057GBALINUSRAPRAYA236064516KIDANGMGC7278242747413COBA2P8V2
36064517MTR077GBALINUSRAPRAYA236064517LAJUTMGC7374252847414COBA2P8V2
36064518PYA052GBALINUSRAPRAYA236064518LEMBAHSMPGAMGC7259252847414COBA2P8V2
36064519PYA022GBALINUSRAPRAYA236064519MANGKUNGMGC7381242747414M:COBA4P12V1
36064520PYA068GBALINUSRAPRAYA236064520MARONGLOMTEMGC7382242747413COBA2P8V2
36064521PYA002GBALINUSRAPRAYA236064521MUJURMGC7275232867414COBA2P8V2
36064522MTR027GBALINUSRAPRAYA236064522NARMADAIIMGC7276252847414COBA2P8V2
36064523MTR015GBALINUSRAPRAYA236064523NARMADAKERUMGC7260252847414ACOMV5
36064524PYA038GBALINUSRAPRAYA236064524NOVOTELLOMMGC7370252847413R:BS120-2V2
36064525PYA092GBALINUSRAPRAYA236064525PANJISARIMGC7270242747413unknown
36064526PYA055GBALINUSRAPRAYA236064526PENGEMBURMGC7258252847413M:COBA4P12V2
36064527PYA004GBALINUSRAPRAYA236064527PENUJAKMGC7257252847413COBA2P8V2
36064528PYA082GBALINUSRAPRAYA236064528PENUNJAKMGC7306242747413unknown
36064529PYA053GBALINUSRAPRAYA236064529PIDENDANGMGC7260252847414unknown
36064530PYA074GBALINUSRAPRAYA236064530PRAYAIIMGC7379242747413R:BS120-2V2
36064531PYA005GBALINUSRAPRAYA236064531PRINGGARATAMGC7371232867413R:BS120-2V2
36064532PYA039GBALINUSRAPRAYA236064532PUYUNGMGC7273252847413F:ACOMCUV1
36064533MTR066GBALINUSRAPRAYA236064533REPNOVOTELMGC7370252847413R:BS120-2V2
36064534MTR076GBALINUSRAPRAYA236064534REPOKLENENGMGC7275232867414COBA2P8V2
36064535PYA006GBALINUSRAPRAYA236064535SENGKOLMGC7258252847413COBA2P8V2
36064536MTR126GBALINUSRAPRAYA236064536SESAOTMGC7284242747413unknown
36064537PYA060GBALINUSRAPRAYA236064537SETANGGORMGC7375242747413COBA2P8V2
36064538MTR016GBALINUSRAPRAYA236064538SURANADIMGC7259252847414R:BS120V1
36064539PYA079GBALINUSRAPRAYA236064539TERMINALPRYMGC7286242747414unknown
36064540PYA069GBALINUSRAPRAYA236064540TERUWAIXPNJMGC7285242747413unknown
36064541PYA003GBALINUSRAPRAYA236064541UBUNGLOMBOKMGC7274232867414R:BS120-2V2
2114331RTG018GBALINUSRARUTENG221143317514252847921R:BS120-2V2
2114334RTG018DBALINUSRARUTENG22114334RUTENGSEC12MD7609252737922R:BS120-2V2
2114336RTG018DBALINUSRARUTENG22114336RUTENGSEC3MD7563212667921R:BS120-2V2
21143325RTG020GBALINUSRARUTENG221143325LABUANBAJOMG7580252957403COBA2P8V2
21143326RTG020DBALINUSRARUTENG221143326LABUANBAJOMD17612252957403COBA2P8V2
21143327RTG020DBALINUSRARUTENG221143327LABUANBAJOMD27630252957403COBA2P8V2
21143328RTG020DBALINUSRARUTENG221143328LABUANBAJOMD37551252957403COBA2P8V2
21143329RTG021DBALINUSRARUTENG221143329TELLABBAJOMD7568252957404M:COBA4P12V2
21143330LBJ006GBALINUSRARUTENG221143330MEROMBOKMG7519252847404unknown
21143331LBJ005DBALINUSRARUTENG221143331GOLOBILASMD7617252957404unknown
21143332LBJ003DBALINUSRARUTENG221143332PANTAIPEDEMD7633252957404unknown
21143333LBJ002DBALINUSRARUTENG221143333PELKOMODOMD7637252957402unknown
21143334RTG007GBALINUSRARUTENG221143334MANOMG7532252847925COBA2P8V2
21143334RTG007GBALINUSRARUTENG221143334MANOMG7578252847925COBA2P8V2
21143336RTG004GBALINUSRARUTENG221143336CANCARMGC7577242967924M:COBA4P12V1
21143338RTG008GBALINUSRARUTENG221143338KUWUSMGC7531252847921M:COBA4P12V1
21143339RTG002GBALINUSRARUTENG221143339LANGKEKMGC7513252957922R:BS120-2V2
21143340RTG010GBALINUSRARUTENG221143340TELGOLONWNGMGC17593252957922M:COBA4P12V1
21143341RTG010GBALINUSRARUTENG221143341TELGOLONWNGMGC7571232867923M:COBA4P12V1
21143343RTG004DBALINUSRARUTENG221143343CANCARMDC7610242967926M:COBA4P12V1
21143344RTG008DBALINUSRARUTENG221143344KUWUSMDC7626252737925M:COBA4P12V1
21143345RTG002DBALINUSRARUTENG221143345LANGKEKMDC71385242857922COBA2P8V2
21143346RTG002DBALINUSRARUTENG221143346LANGKEKMDC37562252847922COBA2P8V2
21143347RTG010DBALINUSRARUTENG221143347TELGOLONWNGMDC7564242967923unknown
21143348RTG024DBALINUSRARUTENG221143348WASOMDC7553252847923unknown
21143349LBJ001DBALINUSRARUTENG221143349BATUCERMINMDC7539242967404unknown
21143350RTG011GBALINUSRARUTENG221143350BARIMGC7516252957926M:COBA4P12V1
21143351RTG017GBALINUSRARUTENG221143351GOLOCALAMGC7596252957403M:COBA4P12V2
21143352RTG015GBALINUSRARUTENG221143352ITENGMGC7582252957921M:COBA4P12V1
21143353RTG005GBALINUSRARUTENG221143353LEMBORMGC7595242967401M:COBA4P12V1
21143355RTG006GBALINUSRARUTENG221143355PAGALMGC7594252957924M:COBA4P12V1
21143356RTG001GBALINUSRARUTENG221143356REOMGC7579242967924COBA2P8V2
21143357RTG012GBALINUSRARUTENG221143357WERANGMGC7534252957926F:ACOMCUV1
21143358RTG011DBALINUSRARUTENG221143358BARIMDC7614242967926M:COBA4P12V1
21143359RTG017DBALINUSRARUTENG221143359GOLOCALAMDC7615242967403M:COBA4P12V2
21143360RTG015DBALINUSRARUTENG221143360ITENGMDC7569242967921COBA2P8V2
21143361RTG005DBALINUSRARUTENG221143361LEMBORMDC17552253067923COBA2P8V2
21143362RTG005DBALINUSRARUTENG221143362LEMBORMDC7631253067922COBA2P8V2
21143363RTG006DBALINUSRARUTENG221143363PAGALMDC17628242967924M:COBA4P12V1
21143364RTG006DBALINUSRARUTENG221143364PAGALMDC27550252957924M:COBA4P12V1
21143365RTG006DBALINUSRARUTENG221143365PAGALMDC37567252957924M:COBA4P12V1
21143366RTG001DBALINUSRARUTENG221143366REOMDC17548252957924M:COBA4P12V1
21143367RTG001DBALINUSRARUTENG221143367REOMDC271389242967921M:COBA4P12V1
21143368RTG012DBALINUSRARUTENG221143368WERANGMDC7616232867926M:COBA4P12V1
21143382LBJ005DBALINUSRARUTENG2211433827603252957925unknown
21143389RTG007DBALINUSRARUTENG2211433895627232427925COBA2P8V2
3606435DPU026GBALINUSRASUMBAWA3606435KWANGKOMGC7369242967421ACOMV6
36064311SBW023GBALINUSRASUMBAWA36064311SUMBAWAIIIMGC71140242967423M:COBA4P12V1
36064312SBW035GBALINUSRASUMBAWA36064312TELUKSANTNGMGC7310253067422COBA2P8V2
36064313SBW032GBALINUSRASUMBAWA36064313AINUNUKMGC7264253067423COBA2P8V2
36064314SBW036GBALINUSRASUMBAWA36064314UNTERMALANGMGC7312253067422COBA2P8V2
36064315DPU011GBALINUSRASUMBAWA36064315REPSNGGRTRPMGC7259253067421COBA2P8V2
36064316SBW102DBALINUSRASUMBAWA36064316SUMBAWABSRMDC7345252957423M:COBA2P8V1
36064317SBW034GBALINUSRASUMBAWA36064317ONGKOMGC7328253067422COBA2P8V2
36064318SBW002GBALINUSRASUMBAWA36064318EMPANGMGC7327253067422COBA2P8V2
36064319SBW006GBALINUSRASUMBAWA36064319LAPEMGC7326252957423COBA2P8V2
36064320SBW001GBALINUSRASUMBAWA36064320UTANMGC7381253067423M:COBA2P8V1
36064321SBW003GBALINUSRASUMBAWA36064321PLAMPANGMGC7311232867422COBA2P8V2
36064322SBW057GBALINUSRASUMBAWA36064322PELATMGC7380253067423COBA2P8V2
36064323SBW038GBALINUSRASUMBAWA36064323BADASMGC71027253067423COBA2P8V2
36064324SBW102GBALINUSRASUMBAWA36064324SUMBAWABSRMGC71025252957423R:BS120V1
36064325SBW013GBALINUSRASUMBAWA36064325PMOYOSUMBWAMGC7370253067421SH:BS81SV2
36064326SBW045GBALINUSRASUMBAWA36064326RHEEMGC7316242967423SH:BS81SV2
36064327SBW051GBALINUSRASUMBAWA36064327LUKLOKAMGC7268253067423COBA2P8V2
36064328SBW044GBALINUSRASUMBAWA36064328KERATOMGC7269252957423SH:BS81SV2
36064329SBW046GBALINUSRASUMBAWA36064329SEPAYUNGMGC7376252957422M:COBA4P12V1
36064330SBW059GBALINUSRASUMBAWA36064330SMBWBESARIIMGC7317252957423M:COBA2P8V1
36064331DPU100GBALINUSRASUMBAWA36064331TELDOROSMBIMGC7308253067421M:COBA4P12V1
36064332SBW011GBALINUSRASUMBAWA36064332REPPLAMPANGMGC7377253067422F:ACOMCUV1
36064333SBW056GBALINUSRASUMBAWA36064333LABUANKURISMGC7379232867422M:COBA4P12V1
36064334DPU013GBALINUSRASUMBAWA36064334BERINGINJYAMGC7307253067421M:COBA4P12V1
36064335DPU023GBALINUSRASUMBAWA36064335PSRMNGGUDMPMGC7323252957421M:COBA4P12V2
36064336DPU010GBALINUSRASUMBAWA36064336KEDINDIREPTMGC7258242967421ACOMV6
36064337SBW050GBALINUSRASUMBAWA36064337KANARMGC7332252957423M:COBA4P12V1
36064338SBW020GBALINUSRASUMBAWA36064338TELOLATPLNGMGC71138242967423F:ACOMCUV1
36064339DPU009DBALINUSRASUMBAWA36064339KILOMDC7290242967421M:COBA4P12V2
36064340SBW017GBALINUSRASUMBAWA36064340MOYOHILIRMGC71137232867423COBA2P8V2
36064341SBW021GBALINUSRASUMBAWA36064341LABANGKAMGC7375242967423COBA2P8V2
36064342SBW071GBALINUSRASUMBAWA36064342LANTUNGAIMLMGC7315253067422M:COBA4P12V2
36064343DPU006GBALINUSRASUMBAWA36064343KEMPOIIMGC7321253067421SH:BS81SV2
36064344SBW031DBALINUSRASUMBAWA36064344REPPEKATMDC7275253067422M:COBA4P12V2
36064345BIM012GBALINUSRASUMBAWA36064345SANGGARMGC7372252957421M:COBA4P12V2
36064346DPU008GBALINUSRASUMBAWA36064346PEKATMGC7371252957421ACOMV6
36064347DPU009GBALINUSRASUMBAWA36064347KILOMGC7306242967421COBA2P8V2
36064348SBW056DBALINUSRASUMBAWA36064348LABUANKURISMDC7338253067422unknown
36064349DPU012GBALINUSRASUMBAWA36064349SORINOMOPKTMGC7374242967421M:COBA4P12V2
36064350SBW075GBALINUSRASUMBAWA36064350REPLABANGKAMGC7331242967422M:COBA4P12V2
36064351SBW021DBALINUSRASUMBAWA36064351LABANGKAMDC27353242967422M:COBA4P12V2
36064352SBW040GBALINUSRASUMBAWA36064352GAPITMGC7313242967422M:COBA4P12V2
36064353SBW068GBALINUSRASUMBAWA36064353MAMANMGC7265242967422COBA2P8V2
36064354SBW028GBALINUSRASUMBAWA36064354BATULANTEHMGC71139242967423COBA2P8V2
36064355DPU002GBALINUSRASUMBAWA36064355KEMPOMNGLWMGC7257253067421F:ACOMCUV1
36064356SBW069GBALINUSRASUMBAWA36064356LOPOKMGC7329242967422M:COBA4P12V2
36064357SBW015GBALINUSRASUMBAWA36064357REPEMPANGMGC7262232867422COBA2P8V2
36064358SBW019GBALINUSRASUMBAWA36064358MOYOHULUMGC7260242967423COBA2P8V2
36064359SBW029GBALINUSRASUMBAWA36064359MUERMGC7324232867422COBA2P8V2
36064360DPU017GBALINUSRASUMBAWA36064360DOROPETIMGC7322242967421M:COBA4P12V1
36064361BIM003GBALINUSRASUMBAWA36064361TAMBORAMGC7305253067421COBA2P8V2
36064362SBW024GBALINUSRASUMBAWA36064362MOYOUTARAMGC71026242967423COBA2P8V2
36064363SBW073GBALINUSRASUMBAWA36064363KARANGDIMAMGC7333252957423M:COBA4P12V1
36064364SBW044DBALINUSRASUMBAWA36064364KERATOMDC7355242967423M:COBA4P12V2
36064365BIM012DBALINUSRASUMBAWA36064365SANGGARMDC7274232867421M:COBA4P12V1
36064366SBW021DBALINUSRASUMBAWA36064366LABANGKAMDC17337232867422M:COBA4P12V2
36064367SBW070GBALINUSRASUMBAWA36064367LITOMGC7267242967422M:COBA4P12V2
36064368SBW059DBALINUSRASUMBAWA36064368SMBWBESARIIMDC71041242967424M:COBA4P12V1
36064369SBW074GBALINUSRASUMBAWA36064369LANTUNGSPKRMGC7263242967422M:COBA4P12V1
36064370SBW050DBALINUSRASUMBAWA36064370KANARMDC7294242967424unknown
36064371SBW073DBALINUSRASUMBAWA36064371KARANGDIMAMDC7278242967424unknown
36064372SBW013DBALINUSRASUMBAWA36064372PMOYOSUMBWAMDC7273253067421unknown
36064373SBW020DBALINUSRASUMBAWA36064373TELOLATPLNGMDC7276253067424unknown
36064374SBW045DBALINUSRASUMBAWA36064374RHEEMDC7292253067424unknown
36064375SBW023DBALINUSRASUMBAWA36064375SUMBAWAIIIMDC7339253067423unknown
readme
*) to calculation the need of additional Abis-pcm needed per BCF/site*) based on extra TS needed for DAP, without TRX-expansion consideration*) database dump using 2011-09-12*) DAP TS expansion is using DAP congestion statistic: formula DAP_7a with the following condition: - using MAX.value of DAP_7a/DAP_ID for date range: 2011-09-06 to 2011-09-12 (7days) - add 1 TS: 20
-
GPRS & DAP Configuration Check
Some CRs already released & executed regarding to GPRS check Enable EGENA
Rectify GTRx without DAP
-
EDAP Tsl Configuration
-
EDAP TS requirements
-
EDAP Tsl Configuration
-
EDAP TS requirements
-
MOM LIST (3/6)
No NotePICTargetRemark6Communication about problem, finding, planning, action, solution, impact analysis, will be communicated by involving every stakeholder including Tsel Headquarter NSN Continuous On going (NSQM need also in loop Preliminary report and excel report) 7Telkomsel requested to provide log alarm per BSC before and after cutover and send both to Telkomsel Region or Telkomsel Headquarter Telkomsel Region : SQA and BSS Team Telkomsel Headquarter : RAO, RANQ, and RAENSN/Tsel Before and After Cutover Region to update 8NSN will activate QoS and/or Fermaint Alarm before cutover with approval Telkomsel Regional. Alarm analysis should be sign by NSN and Tsel.NSN/TselBefore and After CutoverRegion to updateBelow is sample from Balinusra
9Telkomsel and NSN have agreement regarding faulty module on both pre and post cutover. - In case HW faults identified during perf-test before cutover, Tsel will perform FLM - In case HW fault identified during 48 hours after cutover, NSN will perform FLM - In case HW faults identified 48 hours after cutover, Tsel will perform FLM Alarm clearence report should be included on weekly reportNSN/TselContinuousRegion to update
-
MOM LIST (4/6)
No NotePICTargetRemark10Telkomsel and NSN have agreed that only agreed OSS KPI on site level. Traffic should be maintain and shows normal trend after cutover, otherwise it would need NSN explanation and justification. SQA Region should decide normal or abnormal traffic trends in Cluster level.NSN/Tsel ClosedClosed 11Any Change Request on common abis BSC which impacted to service outage during Lebaran Freeze network time require Nodin and should be considered as subject of RAO approval.Tsel InfoClosed 12NSN will provide list of faulty modules and transmission problem to Telkomsel with PIC and target to close.Tsel16 Augt 2011Detail on attachment Balinusra Sumalpua
Kalimantan Sumatera
Sheet1
PIC TI(All)
Count of Date OpenStatus
KPI OwnerDate OpenDate ClosedCLOSEDOPENGrand Total
ANGGA6/16/117/18/1111
6/21/117/1/1111
6/23/117/18/1111
6/30/117/18/1133
7/9/117/13/1111
7/11/117/13/1111
7/18/117/20/1111
7/22/1111
7/25/118/8/1133
7/26/11In progress11
8/8/1199
8/15/1111
7/27/118/8/1133
8/1/11In progress22
8/8/1166
8/2/11In progress11
8/15/1111
8/3/11In progress11
8/8/1166
8/15/1122
8/4/118/15/1111
8/5/118/15/1111
8/8/118/15/1111
8/10/11In progress11
8/18/11In progress11
9/12/1111
8/19/119/12/1133
8/24/11In progress55
9/12/1177
8/25/11In progress11
9/12/1111
9/7/11In progress66
9/12/1111
9/8/11In progress11
9/12/113434
9/12/11In progress66
9/13/11In progress11
MULYADI5/6/117/12/1111
5/9/117/1/1122
7/12/1133
8/23/1111
5/12/115/11/1111
6/24/1111
5/20/117/12/1111
5/25/116/24/1111
5/30/115/30/1133
In progress112
7/1/1133
6/24/1111
7/12/1111
7/13/1133
8/5/1122
8/23/1122
6/3/118/5/1111
6/15/117/12/1122
7/18/1111
8/5/1111
6/16/119/8/1111
5/21/11In progress123
7/12/1111
8/23/1122
6/24/118/5/1111
6/27/11In progress11
7/1/1166
6/29/117/1/1111
7/1/11In progress11
8/5/1111
8/23/1111
7/4/11In progress11
7/6/117/8/1111
8/5/1111
7/11/117/21/1111
7/13/117/22/1122
7/25/118/5/1111
7/26/118/5/1111
7/27/11In progress11
8/5/1133
8/23/1111
7/28/11In progress33
8/5/1111
8/23/1177
9/8/1111
7/29/119/8/1111
8/1/118/5/1111
8/2/11In progress11
8/23/1111
8/4/118/23/1111
8/8/118/23/1155
9/8/1111
8/12/11In progress11
8/23/1122
9/8/1111
8/16/11In progress22
8/23/1111
8/22/11In progress22
8/23/1133
9/8/1122
8/23/11In progress11
8/25/11In progress22
9/5/11In progress33
9/8/1111
9/6/11In progress33
9/8/1144
9/7/11In progress11
9/8/1122
9/8/11In progress11
9/9/11In progress11
9/12/11In progress55
9/13/11In progress55
EKO6/28/11In progress11
8/11/1111
8/18/1111
7/12/11In progress33
7/14/1111
7/15/1122
7/18/1111
8/11/1122
7/18/11In progress11
7/26/1133
8/18/1133
7/21/118/11/1111
7/22/118/11/1122
8/25/1111
7/25/11In progress11
7/26/1122
8/25/1122
8/1/11In progress11
8/11/1111
8/4/11In progress11
8/11/118/18/1122
8/17/118/18/1111
8/18/118/18/1111
8/19/11In progress66
8/25/1144
9/5/1133
8/22/11In progress33
9/5/1111
8/23/11In progress22
9/5/1155
8/25/11In progress33
9/5/1122
9/8/11In progress66
9/12/11In progress11
INDRA6/15/117/14/1111
6/16/117/14/1122
6/19/118/1/1111
6/23/118/15/1111
6/30/117/14/1122
7/1/118/1/1122
8/3/1111
7/4/118/1/1111
7/6/119/6/1111
7/7/117/22/1111
7/26/1111
9/6/1111
7/11/117/26/1122
7/12/11In progress11
7/22/1111
7/13/117/14/1166
7/22/1155
7/14/11In progress11
9/6/1111
7/20/117/22/1111
7/22/117/26/1122
7/25/117/26/1111
8/1/1122
8/15/1111
7/27/11In progress11
7/29/118/1/1144
8/1/11In progress11
8/3/1111
8/15/1111
8/2/118/3/1122
8/5/11In progress11
8/15/1122
8/8/118/15/1133
8/9/11In progress22
8/10/118/15/1111
9/6/1122
8/11/11In progress55
8/15/1133
9/6/1133
8/12/118/15/1111
8/14/119/6/1111
8/16/119/6/1122
8/18/119/6/1133
8/22/119/6/1133
8/23/11In progress22
9/6/1133
8/26/11In progress11
9/6/1111
9/5/11In progress55
9/6/1166
9/6/11In progress11
9/7/11In progress22
9/8/11In progress44
9/9/11In progress33
9/12/11In progress77
RENDRA6/17/11In progress112
7/12/1144
7/15/1111
9/12/1111
6/18/117/12/1122
7/15/1111
6/20/117/12/1111
6/22/11In progress22
7/12/1122
7/15/1111
6/29/117/15/1111
6/30/11In progress11
7/12/1111
7/11/11In progress11
7/18/1111
9/12/1111
7/21/117/28/1111
7/25/11In progress11
7/28/1133
8/15/1111
9/12/1111
7/28/118/15/1133
9/12/1111
7/29/119/12/1111
8/2/119/12/1188
8/3/11In progress11
8/4/118/15/1111
8/11/11In progress22
8/15/1111
8/12/11In progress11
9/12/1111
8/16/11In progress11
9/12/1111
8/18/11In progress33
9/12/1111
8/19/11In progress11
9/12/1144
8/22/11In progress11
9/12/1111
8/25/11In progress22
9/12/11In progress2323
Grand Total354170524
Chart1
9127
9536
4229
7937
4741
15677
510247
Status CLOSED
Status OPEN
count of cases
HW Tracker as of 13rd Sept. 2011
Sheet 2
PIC TI(All)
Date Open(All)
Date Closed(All)
Count of Date OpenStatus
KPI OwnerCLOSEDOPENGrand Total
ANGGA9127118
MULYADI9536131
EKO422971
INDRA7937116
RENDRA474188
ALFBIORN15677233
Grand Total510247757
RF HW Tracker
Alarm Tracker Common Abis
Status :13 Sept. 2011
PIC NPOPIC TI17/04/2011NPO REMARK
Date OpenPriorityKPI OwnerBCFCell IdFBSCBTS/CELL NameBCFLACCellIdProblem DescriptionAlarm RelatedAlarm NumberEquipment AffectedKPI ImpactRecommendationPIC TITroubleshooting_DateActionTCHAVAILSDSRHOSRCDRDate RemarkPerformance after troubleshootingDate ClosedStatus
7-Apr-11ALFBIORNPARE2HCBALUSUMD1351911231851Traffic lostTRX Operation Degraded7607TRX-1HOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub5-MayPerfttest done,simirigid checking ,Replace CU12-JulCLOSED
7-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMDC211911041822Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-5HOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUDCDR improvedCLOSED
7-Apr-11ALFBIORNPARE2HCBARRUCITYMGC1211911151421Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-3 and TRX-4HOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub8-AprReplaced 2 ECUG and 1 FDUAMCOGHOSR, SDSR, TDR are improvingCLOSED
7-Apr-11ALFBIORNPARE2HCBARRUMGC2BARRUMGC3141911161222Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-8BTSHOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUGReplaced 1 FDUAMCOGPerformance is still bad after troubleshooting12-JulCLOSED
7-Apr-11ALFBIORN1226962PARE2HCLASIREMGC2121911026962Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-5HOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUGJune-14: Reset all TRX 7,8 all TRX already working(comfirm with OSS), perftest all CU C2 done, operation succesfull, Tighten semirigit.CDR improvedJune-14: LASIREMGC2 alarm 7745,7706 in TRX 7,812-JulCLOSED
7-Apr-11ALFBIORNPARE2HCMANGKOSOMDC281911241111-3Bad KPIAvailability issue-All TRX'sHOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub14-AprPerftest all ECUDHOSR improved, all other KPI are still bad in line with bad availability23-JunCLOSED
7-Apr-11ALFBIORNPARE2HCMANGKOSOMGC301911261111Bad KPIAvailability issue-All TRX'sHOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub14-AprPerftest all ECUDHOSR improved, all other KPI are still bad in line with bad availability24-MayCLOSED
7-Apr-11ALFBIORNPARE2HCRALLAMGC281911051641Traffic lostTRX Operation Degraded7607All TRX'sHOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub15-AprPerftest all ECUDProblem still exist24-MayCLOSED
7-Apr-11ALFBIORNPARE2HCSEGERIMDC141911041871Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-1HOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUDJuly 04, Perftest CU Time 20:30 witaCDR improved7-JunCLOSED
7-Apr-11ALFBIORNPARE2HCTAKKALASIMGC331911242091Traffic lostTRX Operation Degraded7607All TRX'sHOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub7-MayPerftest all ECUD, TS on site ( 7 may ) ,operation succsesfullProblem still exist18-MayCLOSED
7-Apr-11ALFBIORNPARE2HCTANETERILAUMDC161911142731Traffic lostTRX Operation Degraded7607All TRX'sHOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub15-AprPerftest all ECUD, replace CU, all TRX already WO, perftest all CU done, operation successful, tighten semirigit ( July 5, 2011)Problem still exist9-JunCLOSED
7-Apr-11ALFBIORNPARE2HCTANETERILAUMGC2181911162732Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-5HOSR, CDR, SDSRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUG, perftest all ECUGHOSR, SDSR, TDR are improving27-MayCLOSED
7-Apr-11ALFBIORNPARE2HCTOMPOMG1231911151911Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-1HOSR, CDRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUGHOSR, SDSR, TDR are improving12-JulCLOSED
7-Apr-11ALFBIORNPARE2HCTOMPOMG3231911151913Bad KPI and lost of traffic after migrationTRX Operation Degraded7607TRX-9HOSR, CDRCheck cablings, perftest, HW changeAyyub8-AprReplaced 1 ECUGHOSR, SDSR, TDR are improving12-JulCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMDC1191911131421LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909TRX-1,2,4,5,6,7,8,9,10CDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD66.8295.6999.040.75Problem still exist3-JunCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMDC2191911131422LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909TRX-14CDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD76.997.2399.150.36Problem still exist3-JunCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMDC3201911131423LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909TRX-2,3,4,7,9,10,11,12CDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD54.6694.7795.183.2Problem still exist3-JunCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMDC4201911131424LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909TRX-14, 21,22, 23, 24CDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD55.184.5396.291.49Problem still exist3-JunCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMGC1211911151421LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909All TRX'sCDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayub18-AprPerftest all ECUD, replaced TRX 5,6,7, already 3 time visited ( 12,13,18 april ) and 3 may 2011,Site still alarm when the transmition for mangkoso to barrucity fliker ,TRX blok.......Pak Roy TSEL para pare Already troubleshhoting for this site too..Site have alarm before cut offe38.1286.1396.322.54Problem still exist10-MayCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMGC2211911151422LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909TRX-7, 8CDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD47.8892.7598.171.76Problem still exist18-MayCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMGC3211911151423LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909All TRX'sCDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD53.4793.698.732.39Problem still exist18-JunCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUCITYMGC4211911151424LOW TCHAVAILProblem TRX can't WO,confirm by P'yulius (TSEL)-18/42909TRX-13, 14CDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)Ayyub18-AprPerftest all ECUD52.2894.6892.742.21Problem still exist18-JunCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUINNERMDC241911148711LOW TCHAVAILTransmission Problem Before C-Abis, Confirm by P'Fany2909TransmissionCDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)39.4888.1493.310.4330-MayCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUINNERMGC1251911128711LOW TCHAVAILTransmission Problem Before C-Abis, Confirm by P'Fany2909TransmissionCDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)89.9394.4399.341.6810-MayCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUINNERMGC2251911128712LOW TCHAVAILTransmission Problem Before C-Abis, Confirm by P'Fany2909TransmissionCDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)90.1198.1996.951.7518-MayCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUINNERMGC3251911128713LOW TCHAVAILTransmission Problem Before C-Abis, Confirm by P'Fany2909TransmissionCDR, SDSR, HOSRCheck transmission (blocking, obstacle, BER, interferance)90.1296.296.061.0618-MayCLOSED
18-Apr-11ALFBIORNPARE2HCBARRUMGC3141911161223Low TCH Avail, due to Lock TRX12&TRX10VSWR Alarm (P'ayub Confirm 12/4)7606(VSWR)CDR, SDSR, HOSRCheck feeder cable, antenna, jumper, connectionAyyub6-MayVisited the site, need Feeder 7/8 ( 100m ),Female connector ( 2 pcs),Jumper Outdoor Male ( 2 pcs), rubber and Isolation31.796.6898.251.5512-JulCLOSED
18-Apr-11ALFBIORNPARE2HCBOJOMGC11911229061high DCRAlarm CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-1,2,3,4CDR, SDSRPerftest, Check DUAMCOAyyub19-AprPerftest79.1494.3884.27378965.47279793Performance is still under monitoring12-JulCLOSED
18-Apr-11ALFBIORNPARE2HCKUPAMGC11911261971Low availabilityTRX Operation Degraded7607TRX-1,2,4,5,6,7,8,9,10HOSRPerftestAyyub19-AprPerftest All CU56.7596.394.58144063.678160926-MayCLOSED
18-Apr-11ALFBIORNPARE2HCMANDALLEMDC11911048831Low availabilityTRX Operation Degraded7607TRX-1,2,3,4SDSR, HOSRPerftestAyyub21-AprPerftest all ECUD40.8992.4193.66354310.79536263112-JulCLOSED
18-Apr-11ALFBIORNPARE2HCMANDALLEMDC21911048832Low availabilityTRX Operation Degraded7607TRX-5,6,7,8SDSR, HOSRPerftestAyyub21-AprPerftest all ECUD39.8289.0894.17385721.060713212-JulClosed
18-Apr-11ALFBIORNPARE2HCMANDALLEMDC31911048833Low availabilityTRX Operation Degraded7607TRX-9,10,11,12SDSR, HOSRPerftestAyyub21-AprPerftest all ECUD22.387.4496.35814024.9956178812-JulCLOSED
18-Apr-11ALFBIORNPARE2HCMANDALLEMGC1911028831Low availabilityLow availabilityhigh DCRTRX Operation DegradedHigh VSWR76077606TRX-1,2,3TRX-5,6,7VSWRSDSR, HOSRPerftestCheck VSWRAyyub21-AprPerftest all ECUGMay 9: Alarm 7712 trx 11,12 ( CU 8,9 ) replace backplantrx already working ( oss MR.Moan)..Perfetest all CU done ,Tighten semiringit ( operation succesfull )23.8474.4396.059678713.30275235/12/11Performance is still under baselineMay 18: MANDALLEMGC1 (Doesn't capture traffic) alarm 7712,773812-JulCLOSED
18-Apr-11ALFBIORNPARE2HCPUJANANTINGMGC291911051962Low TCH Avail, high sddropTRX faulty TRX8,7745 until 60% in TRX6-77606, 7745TRX6-7-8SDSRPerftest CU and check semirigid/cablingAyyub19-AprReplaced CU TRX-8 and switch module with sector 156.7639.7500Still under monitor1-JunCLOSED
18-Apr-11ALFBIORNPARE2HCRALLAMDC361911031643Low TCH avail due to Lock TRX21Bad TRX21,Lock (12/4/2011)7607TRX21HOSR,CDRPerftest CU and check semirigid/cablingAyyub15-AprPerftest all ECUD64.4390.5499.110.55Maintained7-JunCLOSED
18-Apr-11ALFBIORNPARE2HCSEGERIMDC11911041871low SDSRMany 7745 and CU faulty7745, 7606TRX-1, TRX-2CDR, SDSR, HOSRPerftestAGUNG16-AprReplaced 1 ECUD, July 04, Perftest CU Time 20:30 wita10088.4997.24349720.239311643Problem still exist7-JunCLOSED
18-Apr-11ALFBIORNPARE2HCSEGERIMGC11911061871Low availabilityTRX Operation Degraded7607TRX-1,2,3SDSR, HOSRPerftest29.4994.9195.38258582.96875Sept 8: Still has 7745 and TRX Operation Degraded alarm on TRX3OPEN
18-Apr-11ALFBIORNPARE2HCSEGERIMGC31911061873Low availabilityTRX Operation Degraded7607TRX-17,18,19,20,21,22SDSR, HOSRPerftest42.0986.494.931080510.055865916-JunCLOSED
18-Apr-11ALFBIORNPARE2HCTAKKALASIMGC2341911262092high DCRMany 7744 & 7607 &76047744, 7607 and 7604TRX-5,6,7,8CDRCheck VSWRAyyub7-MayReplace CU and semiringit for CU 4,All trx already working ( confirm by P.Ferdy ),Perfetst All CU done,tighten semiringid10093.6491.455.7318-MayCLOSED
20-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMDC11911041821Faulty TRXBL-TRX-TRX-3 and TRX-4Block user , perftest and replace if needed12-JulCLOSED
20-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMDC21911041822Faulty TRXBL-TRX-TRX-15 and TRX-16Block user , perftest and replace if needed12-JulCLOSED
20-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMDC31911041823Faulty TRXBL-TRX-TRX-3Block user , perftest and replace if needed12-JulCLOSED
20-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMGC11911061821Faulty TRXTRX faulty7606TRX-2Block user , perftest and replace if needed12-JulCLOSED
20-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMGC21911061822Faulty TRXBL-TRX-TRX-6Block user , perftest and replace if needed12-JulCLOSED
20-Apr-11ALFBIORNPARE2HCTNJNGBUTUNGMGC31911061823Faulty TRXBL-TRX-TRX-10Block user , perftest and replace if needed12-JulCLOSED
25-Apr-11ALFBIORNPARE2HCPALANDROMGC31911262153Bad SDSR due to alarmAlarm CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-11SDSRPerftest and/or change the related HWAyub7-MayBlocking clear for trx 8 after reset from oss ( pak Ferdy )Replace CU,Replace Duamco & semiringit.,all TRX already working23-JunCLOSED
28-Apr-11ALFBIORNPARE2HCSEGERIMDC21911041872Faulty TRX and alarm 7745Alarm TRX faulty and 77457606, 7745TRX-14,15,16,17,18,19,20,21,22,23SDSR, HOSRReset site, check combiner, wiring and connection, and replace hardware if neededAyub9-MayProgress wiring check semirigid,perftest all cu done (operation succsesfull),tighten semirigid, re-visit on May 10)7-JunCLOSED
6-May-11ALFBIORNPARE2HCBALUSUMGC2Bad KPI suspected by bad quality TRXTRX Operation Degraded7607TRX-7CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAyyub10-MayReplace ECUG12-JulCLOSED
6-May-11MULYADI1428881FBULUKUMBABICCUINGMGFlicker due to commercial power issueAll BTSCDR, SDSR, HOSR12-JulCLOSED
9-May-11MULYADI626621FBULUKUMBALEMBANNAMGC1TRX blockBL-TRXTRX-3CDR, SDSR, HOSRPerftest CU and check semirigid/cablingApprul/Yoel11-Mayon going TS .Check semirigit,Replace CU,Tighten Semirigit1-JulCLOSED
9-May-11MULYADI2131443FBULUKUMBAKAJANGMDC3BLK TRXBlocked TRXBL-TRXTRX-16CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG11-May11.5 : Replcae Cu,Perftest >>>result Operation succeseful1-JulCLOSED
9-May-11MULYADI4248161FBULUKUMBASINJAI3MDC1BLK TRXBlocked TRXBL-TRXTRX-5, 9, 10CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG12-May12/5 : TRX 5,9,10 NOT WORKINGChange duamco for trx 5,create Dulna for trx 9 & 10 13/5 : by oss reportig no alarm 20/5 : Perftest & Plug - unplug CU 20/5 : TRX Already Working By OSS Pak.Yudi17.45 WiTA12-JulCLOSED
9-May-11MULYADI5151441FBULUKUMBAKAJANGMGCBLK TRXBlocked TRXBL-TRXTRX-10, 11, 12CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG12-JulCLOSED
9-May-11MULYADI5852191FBULUKUMBASAMAENREMGCTRX Operation DegradedTRX Operation Degraded7607TRX-7,8CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG22-May22/5 : Perftest & Plug unplug CU 5 & 7,Create delate CU 5 & 7 Still alarm RF power Refelected,Change duamco existing ( Dulna & DUVSWR up) but CU 5 still alarm>>>status Lock CU 5,,,,,,,,bu oss ( Need FDUAMCO Helthy )already repalce with new duamco>all trx working12-JulCLOSED
9-May-11MULYADI3241742FBULUKUMBASINJAIMDC2VSWR alarm highBL-TRXTRX-17,21CDR, SDSR, HOSRAGUNGJuly 18: SINJAIMDC2 BL-TRX in TRX 17,21August 05; Still BL TRX8/23/11CLOSED
12-May-11MULYADI8131441FBULUKUMBAKAJANGMDCTRX16 Bad PerformanceTRX Operation Degraded7607TRX-16CDR, SDSR, HOSRPerftest CUAGUNG11-MayReplace CU11-MayCLOSED
12-May-11MULYADI5652141FBULUKUMBAMANNANTIMGCAlarm LAPD FailureTRX Operation Degraded7607CDR, SDSR, HOSRAGUNG5/12/11Current Performance already back to normal24-JunCLOSED
12-May-11ALFBIORNPARE2HCMANGKOSOMDCBL-TRXTRX Operation Degraded7607TRX-1-24CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG12-Mayreset Hardware12-MayCLOSED
20-May-11MULYADI2432023FBULUKUMBAPASIRPUTIHMDC3Zero TrafficOBJECT ADMINISTRATIVE STATE CHANGED BTS WITH NO TRANSACTIONS BCCH MISSING TRX RESTARTED Alarm CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD77107738776777087745CDR, SDSR, HOSRPerftestAGUNG24-May24 may : Lock CU 5, > Traffic Working for sec 3 25 may : TRX 7,8 Lock (7745) 26/5 : Lock TRX 5,7,8 ( 7745 ).28/5:Setting Jumper duamco,Pef\rftest all cu,tighten semirigitPerformance is still under monitoring12-JulCLOSED
21-May-11MULYADI4751122FBULUKUMBABIKERUMGCBad PerformanceAlarm CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-007CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG28-MayET CHECKED,GENSET DOWN24/5 : Perftes & reset Status still alarm27/5:replace CU 10 trx (7 )..all trx already working15/6 : 7745.trx 7reset from oss..alarm clear. June-29 :perftest CU, Delete-create CU, already TRX WO7/11/11June 3: Alarm Transmisi (AIS) alarm 7745,7743 June-29: BL-USR in TRX 3,7 1 July : Still alarm 7745 in TRX 7. 11 July : Still alarm 7745,7705[LAPD FAILURE]13/9; BIKERUMGC2 alarm 7745 in TRX 7OPEN
21-May-11MULYADI27 2732171 32172FBULUKUMBAKALUMPANGMDCLow availabilityTRX-1-6 TRX-7-9 TRX12-17CDR, SDSR, HOSRJune 3: Perftest CU and check semirigid/cablingAGUNG21/5 : ISSUE by oss ( VSWR high )& reset CU. G26 25/5 : request reset sec 3 ( trx 14 & 15 )still alarm ( request by Pak Mulyadi NPO ) 26/5: Trx 12 vswr high27/5:Replace CU 0,Perftest,tigthen semirigit10/6 : VSWR high At trx 14,15....june-20: untuk BCF 27 ( VSWR high,dan menunggu module )...data VSWR akan dikirim ke Tsel.PAk Sahatjune-28:Reset from OSS, alarm clear, all TRX already working03/8: KALUMPANGMDC1 sudah di trshooitng,Untuk Kalumpang MDC 3 trx 15,16 high vswrJune 3: Alarm Transmisi (AIS) 7767,7607July 13: KALUMPANGMDC1 BL-TRX in TRX 5 KALUMPANGMDC3 BL-SYS in TRX 12 and BL-TRX in 14-16July 18: KALUMPANGMDC1 BL TRX in TRX 4-6, KALUMPANGMDC2BL-SYS in TRX 7-10, KALUMPANGMDC3 BL-TRX in TRX 14-1727/7: KALUMPANGMDC1 alarm 7745 100% in TRX 2, KALUMPANGMDC3 in TRX 12.8/23/11CLOSED
21-May-11MULYADI86 86 8659281 59282 59283FBULUKUMBAPROSNJAITNGMGC1PROSNJAITNGMGC3PROSNJAITNGMGC2Low availabilityAGUNG21/5 : Lock CU Checked by oss12-JulCLOSED
21-May-11MULYADI61 61 6152861 52862 52863FBULUKUMBASINJAITIMURMGC1SINJAITIMURMGC2SINJAITIMURMGC3Low availabilityAGUNG21/5 : perftest from oss ( by pak Yudi )trx 2 ,3,4,Working after perftes..trx 7,8 ( still blok trx ) 22/5 :: Trx 7 ,8 blocking,CU 5 & 7 failed,Duvswr 7 and degraded>>>Perftest cu 5 & 7 and create delete..Perftest DUVSWR 7 ( still alarm after 3 minute ).plug unplug duamco>>>>no alrm>all trx already woking7/12/11Still shown BL-TRX in TRX 7,8,1112/9; SINJAITIMURMGC2 BL TRX in TRX 7,812/9; SINJAITIMURMGC3 BL TRX in TRX 11Open
21-May-11MULYADI23 5331943 51943FBULUKUMBAUJUNGBULUMDC3UJUNGBULUMGC3Low availabilityAGUNG21/5 : Power Issue,,,,Rect faulty, lock CU Checked by oss 25/5 : Coba module replaced ( Spare module Faulty ) From PT .Inti 26/5: replace coba,site working and have traffic,CU (2,4,6 ) alarm 11/6: Perftest CU ( OK ),Check Backplane ( ok ),Check Data cabel on Bcakplane area ( ok ),..Suspect : Celic cable,data cabel from base rack ( pelangi kabel )24/6: change cable rainbow from baserack to existing rack, all trx already working, alarm clear.7/12/11July 4: UJUNGBULUMDC4, BL-DGN in TRX 17 July 13: UJUNGBULUMDC3 : BL-TRX in TRX 12,13 (high VSWR)July 13: UJUNGBULUMGC3 : BL-TRX in TRX 11July 18: UJUNGBULUMGC1 BL-TRX in TRX 38/23/11CLOSED
21-May-11MULYADI5351944FBULUKUMBAUJUNGBULUMGC4Low availabilityAGUNG21/5 : Power Issue,,,,Rect faulty, lock CU Checked by oss 25/5 : Coba module replaced ( Spare module Faulty ) From PT .Inti 26/5: replace coba,site working and have traffic,CU (2,4,6 ) alarmCLOSED
25-May-11MULYADI59 5952401 52402FBULUKUMBABULUPODDOMGC1BULUPODDOMGC2TCH Availability decreaseBL-TRXTRX 2CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG24-JunCLOSED
30-May-11MULYADI1328681FBULUKUMBABONTOTANGAMGCAlarm in AIS Alarm /TransmissionTRX Operation Degraded7607CDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNG1-JulCLOSED
30-May-11MULYADI79 79 7948681 48682 48683FBULUKUMBABONTOTANGAMD1BONTOTANGAMD2BONTOTANGAMD3Low availabilityCDR, SDSR, HOSRAGUNG30-MayAllready workingJune 15: OMU Block July 13: Alarm Transmisi 7705 [LAPD Failure]July 18: BONTOTANGAMD1 BL SYS in TRX 48/5/11CLOSED
30-May-11MULYADI13 13 1328681 28682 28683FBULUKUMBABONTOTANGAMGC1BONTOTANGAMGC2BONTOTANGAMGC3Low availabilityCDR, SDSR, HOSRAGUNG1-JulCLOSED
30-May-11MULYADI1128283FBULUKUMBABULUKUMBA2MGC3Low availabilityBlok TRXTRX-10,11AGUNG30-MayReplace duamco,Tighten semirigit,Perftest,All trx already working30/6:already improved30-MayCLOSED
30-May-11MULYADI5952401FBULUKUMBABULUPODDOMGC1Low availabilityAGUNG24-JunCLOSED
30-May-11MULYADI83 83 8359911 59912 59913FBULUKUMBAGRANTUNGANMG1GRANTUNGANMG2GRANTUNGANMG3Low availabilityAGUNG13-JulCLOSED
30-May-11MULYADI626621FBULUKUMBALEMBANNAMGC1Low availabilityAGUNG30/6: TRX3 still BL-USR1-JulCLOSED
30-May-11MULYADI8159921FBULUKUMBAPRBNTOTIROMGCLow availabilityCDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNGJune 3: alarm 7708 [TRX RESTARTED]8/5/11CLOSED
30-May-11MULYADI6458811FBULUKUMBAPROTELTALLEMGC1Low availabilityAGUNG12-JulCLOSED
30-May-11MULYADI226402FBULUKUMBABONTOBAHARIMGCLow availabilityCDR, SDSR, HOSRPerftest CU and check semirigid/cablingAGUNGJune 28: Reset from OSS, alarm clear, all TRX already working14/7 : Perftest trx 2 80%8/5/11CLOSED
27-Jun-11MULYADI526561FBULUKUMBAMACINAMGC1BL-TRXTRX-1,3AGUNG28-JunPerftestDUVSWR, unplug-plug DUAMCO, alarm clear,all TRX already WO.30/6: already improved1-JulCLOSED
27-Jun-11MULYADI626621FBULUKUMBALEMBANNAMGC1BL-USRTRX-3AGUNG28-JunReset from OSS, alarm clear, all TRX already working30/6: TRX3 still BL-USR1-JulCLOSED
27-Jun-11MULYADI1128283FBULUKUMBABULUKUMBA2MGC3BL-TRXTRX-10,12AGUNG28-JunPerftestDUVSWR, unplug-plug DUAMCO, alarm clear,all TRX already WO.30/6:already improved1-JulCLOSED
27-Jun-11MULYADI2131441FBULUKUMBAKAJANGMDCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 5AGUNG28-JunReset from OSS, alarm clear, all TRX already working30/6: already improved1-JulCLOSED
27-Jun-11MULYADI1328681FBULUKUMBABONTOTANGAMGBL SYSCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 2,5AGUNG28-JunReset from OSS, alarm clear, all TRX already working30/6: already improved1-JulCLOSED
27-Jun-11MULYADI926832FBULUKUMBAPROTELSINJ1MGC2PROTELSINJ1MGC3BL-USRCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-5,6,7 BL-TRX - TRX 8AGUNG28-JunReset from OSS, alarm clear, all TRX already workingJuly 4: BL-TRX in TRX 8 July 12: Still alarm 7745 in TRX 7 at trheshold > 80%27/7: PROTELSINJ1MGC2 still shown alarm 7745 in TRX 812/9; PROTELSINJ1MGC2 Still alarm 7745 in TRX 605/9; PROTELSINJ1MGC2 STILL ALARM 7745 IN TRX 6OPEN
27-Jun-11MULYADI6258361FBULUKUMBAPRORILAUATEMGBL TRXCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745AGUNG28-JunReset from OSS, alarm clear, all TRX already working30/6: already improved1-JulCLOSED
28-Jun-11EKOPASAR WAJO1SIOTAPINAMMGAGUNG28-JunTS, OMU Blocked26/7: SIOTAPINAMMG2 alarm 7745 in TRX 6,8OPEN
28-Jun-11EKOPASAR WAJO1KALISUSUMGCTCH Drop > 4%AGUNG28-JunTS, alarm clearJuly 13: alarm 7607 &7744July 15: KALISUSUMGC2 BL-BTS in TRX 5-8July 25: Still BL_TRX in TRX 5-88/11/11CLOSED
28-Jun-11EKOPASAR WAJO1PASAR WAJOMDCAGUNG28-JunTS, alarm clear8/18/11CLOSED
29-Jun-11MULYADI1931211FBULUKUMBAPONREMDCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-9,13,15,16AGUNG29-JunPerftest CU, unplug-plug CU, changed CU 6,2,3 alarm clear30/6: already improved1-JulCLOSED
29-Jun-11RENDRA2829582SIDRAP1KADIDIMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX -5AGUNG29-Junperftest all CU done,operation successful, tighten semirigit7/12/11kadidimgc2 still alarm 7745 in TRX 5 with value of percentage 100 %15-JulCLOSED
30-Jun-11RENDRA3548131SIDRAP1KANYUARAMDCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 3AGUNG30-Junperftest all cu done, plug - unplug FDUAMCOD, operation successful, tighten semirigit.12-JulCLOSED
30-Jun-11RENDRA141551SIDRAP1SIDRAPMDCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-5,6,9,13,14,16,17AGUNG30-Junperftest all cu done, operation successful, tighten semirigit. All trx already WO.OPEN
30-Jun-11ANGGAPARE1PARECITY2MGC3TRX FaultyTRX 8, TRX 10, TRX 11 and BL-RST in TRX 918-JulCLOSED
30-Jun-11ANGGAPARE1BAUMASEPPEMGC1TRX Faulty (BL-TRX)TRX 418-JulCLOSED
30-Jun-11ANGGAPARE1PLTDSUPPAMDC1RX Faulty (BL-TRX)TRX 618-JulCLOSED
30-Jun-11INDRAPALOPO2MAPPADECENGMDC2BL-TRX.TRX 614-JulAlready TS8/8; Module Problem14-JulCLOSED
30-Jun-11INDRAPALOPO2SUKAMAJUMDC3BL-TRX.TRX 1114-JulAlready TS14-JulCLOSED
1-Jul-11INDRAPALOPO2BAEBUNTAMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 2,3,4july-22: Monitoring3-AugCLOSED
1-Jul-11INDRA1642312PALOPO1LAUWOMDC2Block TRXCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 11,12AGUNG11-JulReplace FDUAMCOJuly 18: Replace ECUD, Alarm Clear. Time 22:10 WitaJuly 20: BL-TRX in 16,18July 18: BL-TRX in TRX 181-AugCLOSED
1-Jul-11INDRAPALOPO2MAPPADECENGMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 10,15July 18: BL-TRX in TRX 11July 22: Monitoring1-AugCLOSED
1-Jul-11MULYADI9959121FBULUKUMBANSERABARUMGCBad performance TCH Availibility BSC levelJuly 12: BL-TRX in TRX 1,2,4,7 and BL-RST in TRX 3July 13: NSERABARUMG2 BL-TRX in TRX 7,823-AugCLOSED
1-Jul-11MULYADI10546831FBULUKUMBANSPROSINJAI1MDCBad performance TCH Availibility BSC levelCLOSED
1-Jul-11MULYADI2432021FBULUKUMBAPASIRPUTIHMDC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 2,3,45-AugCLOSED
4-Jul-11MULYADI5952402FBULUKUMBABULUPODDOMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 6,7,8CLOSED
4-Jul-11INDRAPALOPO2MASAMBACITYMDCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-2-12AGUNG4-JulReplace Module,perftest, alarm clear. Time 20:13 witaJuly 22: Monitoring1-AugCLOSED
6-Jul-11MULYADI3341743FBULUKUMBASINJAIMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-1-88-JulCLOSED
6-Jul-11INDRAPALOPO2BNTUTERPEDOMDC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-2-5july 26: Monitoring6-SepCLOSED
6-Jul-11MULYADI6052442FBULUKUMBAKAMBUNOMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-6,87-JulTS done, Replace CU (TRX 6, 7,8) perftest, alarm clear.5-AugCLOSED
7-Jul-11INDRAPALOPO2URASOMDC3Block TRXCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 11,12AGUNG11-JulReplace CUJuly 20: Still shown alarm 7745 in TRX 10-128/09; Alarm 7745 at 100 % in TRX 116-SepCLOSED
7-Jul-11INDRAPALOPO2URASOMGC2TRX FaultyCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-88/8; Module ProblemJuly 15: Monitoring26-JulCLOSED
7-Jul-11INDRA4258372PALOPO1SKPMALANGKEMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-6,7,87-JulJuly 7, on going tshoot PIC P. YoelReplace DUAMCO sec_2, replace CU 6 & 7, alarm clear8/8; BCF 42 : VSWR High22-JulCLOSED
9-Jul-11ANGGA2741533PARE1SUPPAMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 5, 6, 7SDSR, HOSRAGUNG13-JulPerftest13-JulCLOSED
11-Jul-11RENDRA4442441SIDRAP1BATUBATUMDC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX-4,5,6,7AGUNGReplace CU,Perftest,tighten semirigitJuly 15: still shown alarm 7745OPEN
11-Jul-11RENDRA5458271SIDRAP1TBGDUAPITUEMGCTRX OPERATION DEGRADEDLAPD FAILURE7607, 7705TRX-1-12July 15: TBGDUAPITUEMGC1 alarm 774418-JulCLOSED
11-Jul-11RENDRA3749501SIDRAP1ALAKUANGMDCTRX operation degraded7607TRX-1-119/12/11CLOSED
11-Jul-11ANGGA2741532PARE1SUPPAMDC2TCH Block increased, and high HO FailSDSR, HOSRAGUNG13-JulPerftest13-JulCLOSED
11-Jul-11INDRA356258162583PALOPO1BUALUWUMGC1BUALUWUMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX2,3,4TRX-10,11,12HOSR,SDSR,CDRAGUNG18-JunReset trx 5,10,18 result alarm 7745 22/7: Replace ECUG for trx 9 & 10Perftest All CUJuly-20: BUALUWUMGC1, alarm 7745 in TRX 2,3,4. BUALUWUMGC3alarm 7745 in TRX 10,11,12.26-JulCLOSED
11-Jul-11INDRA296177261773PALOPO1PALOPO2MGC2PALOPO2MGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 5,7,8TRX 9,11,12SDSR, HOSRJuly 20: PALOPO2MGC2, alarm 7745 in TRX 5,7,8. PALOPO2MGC3 alarm 7745 in TRX 9,11,12July 20: Monitoring26-JulCLOSED
11-Jul-11MULYADI3642341FBULUKUMBATANJUNGBIRAMDCLAPD FAILURE, BTS WITH NO TRANSACTIONS7705 ,7738AGUNG14-Jul14/7 : repalce trx 12,cu 8,alarm clear20/7: Replace ECUD 6 for trx 12 Perftetst All CU sector 1 tighthen semirigit, Alarm Clear ,traffic working all sectorJuly 15: MonitoringJuly 18: TANJUNGBIRAMDC3 BL-TRX in TRX 1221-JulCLOSED
12-Jul-11INDRA14211142112PALOPO1WALENRANGMDCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLDTRAFFIC CHANNEL ACTIVATION FAILURE77457725TRX 15TRX 122-AugReplace ECUDPerftestJuly 20: WALENRANGMDC2 alarm 7745 in TRX 15OPEN
12-Jul-11INDRAPALOPO1TELLUWANUAMGCTRAFFIC CHANNEL ACTIVATION FAILURE7725TRX-4,5,8,10,12AGUNG19-JulReplace ECUG trx 1, Alarm Clear. Time 18:20 WitaJuly 14: TELLUWANUAMGC1 BL-TRX in TRX 1 July-15: TELLUWANUAMGC2 > MonitoringJuly 18: BL-RSL in TRX 1-422-JulCLOSED
12-Jul-11EKOPASAR WAJO1CBBINONGKRKMGC1BL-TRXTRX 3,4July 15: BL-TRX in TRX 3,July 18: BL-TRX in TRX 3-4,July 22: BL-RSL in TRX 1-4July 26: BL TRX in TRX 318/8; BL TRX in TRX 3OPEN
12-Jul-11EKOPASAR WAJO1WANCIMDC3BL-TRX & BL- SYSTRX 2, 1114-JulCLOSED
12-Jul-11EKOPASAR WAJO1WANCI2MGC3BL-TRXTRX 9July 15: WANCI2MGC1 BL-TRX in TRX 2. WANCI2MGC3 still BL TRX July 18: Alarm 7745 in TRX 10, July 22: BL-TRX in TRX 918/8; BL TRX in TRX 9OPEN
12-Jul-11EKOPASAR WAJO1TOMIAISATMGC2BL-TRXTRX 418-JulCLOSED
12-Jul-11EKOKENDARI2ANGGABERIMGCTRAFFIC CHANNEL ACTIVATION FAILURE7725TRX 1-10July 22: alarm 7607 in TRX 1,2,3 TRX 5,6,7 TRX 9,1027/7 : ANGGABERIMGC3 BL-TRX in TRX 12OPEN
12-Jul-11EKOKENDARI2MEKARSARIMGCTRAFFIC CHANNEL ACTIVATION FAILURE7725TRX 1,2,4,5,7,815-JulCLOSED
12-Jul-11EKOKENDARI2NMEKARSARIMGCTRAFFIC CHANNEL ACTIVATION FAILURE7725TRX 2,3,415-JulCLOSED
12-Jul-11EKOKENDARI2NSANGGABERIMDCTRAFFIC CHANNEL ACTIVATION FAILURE7725TRX 2,3,427/7: NSANGGABERIMD2 BL-TRX in TRX 2,3,48/11/11CLOSED
12-Jul-11EKOKENDARI2TONGAUNAMGCTRAFFIC CHANNEL ACTIVATION FAILURE7725TRX 1,2,3,4,6,7July 22: TONGAUNAMGC1 & TONGAUNAMGC1 alarm 7607 in TRX 1,2 TRX 3,4 and TONGAUNAMGC3 alarm 7745 in TRX 68/11/11CLOSED
13-Jul-11INDRA4957251PALOPO1NSDMAMSANGANMGBL-RSLTRX 1-1222-JulCLOSED
13-Jul-11INDRA5357201PALOPO1NSDMTLATUPAMGBL-RSLTRX 1-1222-JulCLOSED
13-Jul-11INDRA5446852PALOPO1NSPROPALOPO1MD2BL-TRXTRX 7,822-JulCLOSED
13-Jul-11INDRA554686246862PALOPO1NSPROPALOPO4MD2NSPROPALOPO4MD3BL-TRXTRX 11,12TRX 23,24AGUNG14-JulAlready TS22-JulCLOSED
13-Jul-11INDRA5637241PALOPO1NSPRJSUDIRMNMDBL-RSLTRX 3,4 TRX 7,8 TRX 11,12AGUNG14-JulAlready TS22-JulCLOSED
13-Jul-11INDRA74934149342PALOPO2CAKARUDUMDC1CAKARUDUMDC2BL-SYSTRX 2 TRX 9AGUNG14-JulAlready TSJuly 18: BL-RSL in TRX 1-1314-JulCLOSED
13-Jul-11INDRA142926129262PALOPO2KMPUSBAPTEKMGC1KMPUSBAPTEKMGC2BL-SYS, BL-DGNBL-SYSTRX 2,3 TRX 6AGUNG14-JulAlready TSJuly 18: KMPUSBAPTEKMGC BL-SYS & BL-TRX in TRX 2,6,1114-JulCLOSED
13-Jul-11INDRA1549932PALOPO2MPPEDECENG2MDC2BL-TRXTRX 3,5,6AGUNG14-JulAlready TSJULY: BL-SYS in TRX 1 & 214-JulCLOSED
13-Jul-11INDRA164231142312PALOPO2LAUWOMDC1LAUWOMDC2BL-TRXBL-RSTTRX 6TRX 14AGUNG14-JulAlready TS8/8; Module ProblemJuly 18: BL-TRX in TRX 7 & 15July 20: LAUWOMDC2 alrm 7745 in TRX 10,13,14,15,16,17.14-JulCLOSED
13-Jul-11INDRA1949261PALOPO2KMPUSBAPTEKMDC1BL-RSLTRX 5,7AGUNG14-JulAlready TS14-JulCLOSED
13-Jul-11INDRA4757221PALOPO2NSDMTRMPOANGMGBL-USRTRX 1-12AGUNG14-JulAlready TS8/07; NSDMTRMPOANGMG2, Alarm 7745 100% in TRX 814-JulCLOSED
13-Jul-11MULYADI1128283FBULUKUMBABULUKUMBA2MGC3BL-TRXTRX 10,1222-JulCLOSED
13-Jul-11MULYADI10257371FBULUKUMBANSPROBIALOMGBL-RSL & BL-TRXTRX 1-1222-JulCLOSED
14-Jul-11INDRA203238232383PALOPO1COMBTRPLPOMDC2COMBTRPLPOMDC3BL-RSLBL-SYSTRX 6-12, 17-24TRX 14July 20: Waiting Module by Tsel(NO Area)TRX faulty,LAPD Failure (RF Module detected LNA Failure)July 20:COMBTRPLPOMDC2 alarm 7745 in TRX 4July 26: COMBTRPLPOMDC3 alarm 7745 in TRX 14-238/09; COMBTRPLPOMDC2 Still alarm 7745 at 100%9/6/11CLOSED
14-Jul-11INDRAPALOPO2SALULINOMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 3SDSR, HOSR, DCRAGUNG14-JulAlready TSJuly 15: Still alarm 7745July 20: Still alarm 7745 in TRX 28/09; SALULINOMGC1 still alarm 7745 at 100%OPEN
14-Jul-11ALFBIORN5362751PINRANG1BARIBATUMGC1alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 1,2,4AGUNG3-AugRepalce CU 0 trx 3,Replace Fduamco 1 rack 0perftest All CUJuly 18: BL-TRX in TRX 3, BARIBATUMGC2 in TRX 78/15/11CLOSED
14-Jul-11ALFBIORN2451193PINRANG1BENTENGMGC3alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 1010/8; Stil alarm 7745 at 100% in TRX 108/15/11CLOSED
14-Jul-11ALFBIORN2152492PINRANG1CEMPAEXPLTNMGC2alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 6,7July 18: BL-TRX in TRX 78/15/11CLOSED
14-Jul-11ALFBIORN4358002PINRANG1GANDASILMGC2alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 7,8AGUNG14-JulPerftest ,need replace CUG trx to ECUGSept 7: 7745 alarms has been cleared7-SepCLOSED
14-Jul-11ALFBIORN931131PINRANG1MANARANGMDC1alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 4Aug 25: No alarms found; HOSR, SDSR and TCH DCR are ok8/25/11CLOSED
14-Jul-11ALFBIORN11615416154261543PINRANG1PINRANGMGC1PINRANGMGC2PINRANGMGC3alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 3,4TRX 7TRX 11AGUNG19-JulReplace CU for trx 2,5,6,9,10 to ECUG for trx 2,3,5,6,9,10. Alarm Clear ,Traffic working. Time 14:20 Wita. Note: still need Replace 3 CUG to 3 ECUGJuly 18: BL-TRX in TRX 2,5,6,9,108/15/11CLOSED
14-Jul-11ALFBIORN1726891PINRANG1PROPINRANG1MGC1alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 3,414-Julcant be assignSept 7: 7745 alarms has been cleared KPI s are OK7-SepCLOSED
14-Jul-11ALFBIORN2948103PINRANG1RSUENREKANGMDC3alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 9-1914-Jultrx can't be assignJuly18: BL-TRX in TRX 127/7: Still shown alarm 7745 until 100% in TRX 10-1923-AugCLOSED
14-Jul-11ALFBIORN838093PINRANG1TBGPLETEANGMDC3alarm 7745 until 100%CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 14-1914-JulNO HW on trx 20Sept 8: Still has 7745 and TRX Operation Degraded alarm in ALL TRXOPEN
18-Jul-11EKOPASAR WAJO1CBBINONGKRKMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 98/18/11CLOSED
18-Jul-11EKO14PASAR WAJO1PASARWAJOMDC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 36-AugMoving Left COBA to Right COBA,Perftets All CU25/7: PASARWAJOMDC1 Still shown alarm 7745 in TRX 2,3,58/18/11CLOSED
18-Jul-11EKO16PASAR WAJO1PASARWAJOMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 325/7: alarm 7745 in TRX 3,409/8; PASARWAJOMGC1 still alarm 77458/18/11CLOSED
18-Jul-11EKO26PASAR WAJO1TOMIAPERMANMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 925/7: Still shown alarm 7745 in TRX 526-JulCLOSED
18-Jul-11EKOPASAR WAJO1TBGPTUNORESMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 426-JulCLOSED
18-Jul-11EKOPASAR WAJO1TAMPARAMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 425/7: Still alarm 7745 in TRX 409/8; still alrm 7745 in TRX 2,311/8; BL TRX in TRX 4OPEN
18-Jul-11EKO35PASAR WAJO1KALEDUPAMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 126-JulCLOSED
18-Jul-11ALFBIORNPINRANG1PINRANGMDC3BL-TRXCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 3, TRX 2,5,6,7,12AGUNG20-JulReplace ECUG trx 2,Perftest C3 all CU,tighten semirigitSept 8: Still has TRX Faulty on TRX 3; All TRX has TRX Operation Degraded Alarm; TRX 12 has 7745 AlarmOPEN
18-Jul-11ALFBIORNPINRANG1CBTBUPTIPNGMGC1CBTBUPTIPNGMGC3BL-TRXTRX 2,6AGUNG18-Julneed ECUG for trx 2need ECUG for trx 6July 18: CBTBUPTIPNGMGC1 Alarm 7745 in TRX 3,4. CBTBUPTIPNGMGC2 in TRX 6,8. CBTBUPTIPNGMGC3 in TRX 7,815/8; CBTBUPTIPNGMGC1 Still alarm 7745 in TRX 48/25/11CLOSED
18-Jul-11ALFBIORNPINRANG1RSUENREKANGMGC1RSUENREKANGMGC3BL-TRXTRX 3, 20AGUNG14-JulCant be assign03/8:Replace CU 3 trx 3, perftest All CUAug 25: BL-TRX already resolved, no TCH Blocking8/25/11CLOSED
18-Jul-11ALFBIORNPINRANG1SALUBARANIMDCBL-TRXTRX 723-AugCLOSED
18-Jul-11ALFBIORNPINRANG1BUNTUBATUMDC1BL-TRXTRX 48/15/11CLOSED
18-Jul-11ALFBIORNPINRANG1CAKKEMGC3BL-TRXTRX 118/15/11CLOSED
18-Jul-11ALFBIORNPINRANG1BARAKAMGC2TRX FAULTY7606TRX 15AGUNG3-AugRepalce CU 11 trx 16,perftest All CU8/25/11Sept 8: Alarms cleared and no BL-TRX8-SepCLOSED
18-Jul-11ALFBIORNPINRANG1BENTENGMDCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX (2,11) (17-19)27/7: BENTENGMDC2 alarm 7745 at 100% in TRX 12-238/15/11CLOSED
18-Jul-11ALFBIORNPINRANG1CEMPAEXPLTNMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 68/15/11CLOSED
18-Jul-11ALFBIORNPINRANG1GANDASILMGC1GANDASILMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 1-4TRX 9-12AGUNG14-Julperftest,need replace Duamco8/25/1103/8; GANDASILMGC1 TRX FAULTY in TRX 1-48/25/11CLOSED
18-Jul-11ALFBIORNPINRANG1KOTUMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 58/15/11CLOSED
18-Jul-11ALFBIORNPINRANG1MANARANGMDC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 48/25/11Aug 25: No alarm; TCH DCR, SDSR and HOSR are OK8/25/11CLOSED
18-Jul-11ALFBIORNPINRANG1NSPRPINRANG1MDC3TRX FAULTY7606TRX 9,108/25/11Aug 25: No active alarms;8/25/11CLOSED
18-Jul-11ALFBIORNPINRANG1PINRANGINERMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 98/15/11CLOSED
18-Jul-11ALFBIORNPINRANG1CAKARUDUMGC1CAKARUDUMGC2BL-RSLTRX 1-822/7: CAKARUDUMGC1 alarm 7745 in TRX 2,3,48/15/11CLOSED
18-Jul-11ANGGAPARE1PAREPAREMDC2BL-TRXTRX 15,2120-JulCLOSED
18-Jul-11ANGGAPARE1ANDIMAPATONMDC2ANDIMAPATONMDC3BL-TRXBL-DGNTRX 13TRX 1July 20: ANDIMAPATONMDC3 => CLOSED22-JulCLOSED
20-Jul-11INDRA215271152712PALOPO1LATUPPAMGC1LATUPPAMGC2BL-RSLTRX 1-4TRX 5-822-JulCLOSED
21-Jul-11EKO49KENDARI2MEKARSARIMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 12July 22: MEKARSARIMGC3 alarm 7607 in TRX 9,10,11,12August 02: Still alarm 7745 100% in TRX 128/11/11CLOSED
21-Jul-11RENDRASIDRAP1BENDOROMDC3TRX faulty7606TRX 325/7: BL-TRX in TRX 37/28/11CLOSED
22-Jul-11INDRA114994149943PALOPO1SERITIMDC1SERITIMDC3BL-SYSTRX 2,822/7: SERITIMDC1, BL-SYS in TRX 2 & SERITIMDC3 BL-SYS in TRX 826-JulCLOSED
22-Jul-11INDRA3049041PALOPO1PEPABRIMDCBL-SYSTRX 2. TRX 6. TRX 1426-JulCLOSED
22-Jul-11EKO115491254913PASAR WAJO1CBBINONGKRKMGC2CBBINONGKRKMGC3BL-RSLTRX 5-8TRX 9-128/11/11CLOSED
22-Jul-11EKO1544152PASAR WAJO1PASARWAJOMDC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 5,6,9,1025/7: Still BL-TRX in TRX 3 and alarm 77458/25/11CLOSED
22-Jul-11EKO49KENDARI2MEKARSARIMGC1MEKARSARIMGC2TRX OPERATION DEGRADED7606TRX 2,3TRX 5,78/11/11CLOSED
25-Jul-11INDRA2032383PALOPO1COMBTRPLPOMDC3BL-TRXTRX 15AGUNG4-AugRepalce ECUD,Perfteset,tighthen semirigit8/15/11CLOSED
25-Jul-11INDRA3361093PALOPO1PALOPO1MGC3BL-TRXTRX 121-AugCLOSED
25-Jul-11INDRA749342PALOPO1CAKARUDUMDC2BL-SYSTRX 926-JulCLOSED
25-Jul-11INDRA164231142312PALOPO1LAUWOMDC1LAUWOMDC2BL-TRXTRX 6TRX 141-AugCLOSED
25-Jul-11ANGGA941322PARE1PAREPAREMDC2BL-TRXTRX 158/8/11CLOSED
25-Jul-11ANGGA124222142222PARE1ANDIMAPATONMDC1ANDIMAPATONMDC2BL-TRXTRX 3TRX 138/8/11CLOSED
25-Jul-11RENDRA742642SIDRAP1LACINRANGMDC2BL-TRXTRX 15,167/28/11CLOSED
25-Jul-11RENDRA1562482SIDRAP1AMPARITAMGC2BL-TXTRX 712/9; Alarm 7745 in TRX 59/12/11CLOSED
25-Jul-11RENDRA2151432SIDRAP1BILOKKAMGC2BL-TXTRX 7OPEN
25-Jul-11RENDRA3349603SIDRAP1PDANGLOANGEMDC3BL-TXTRX 15,187/28/11CLOSED
25-Jul-11RENDRA3548131SIDRAP1KANYUARAMDC1BL-TXTRX 38/15/11CLOSED
25-Jul-11ANGGAPARE1PARECITYMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 11.128/8/11CLOSED
25-Jul-11EKO2PASAR WAJO1WARINTAMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 226-JulCLOSED
25-Jul-11EKO7PASAR WAJO1UMALAOGEMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 826-JulCLOSED
25-Jul-11EKO23PASAR WAJO1CBWNGKAWNCIMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 1,3,411/8; BL TRX in TRX 38/25/11CLOSED
25-Jul-11EKO27PASAR WAJO1TOMIAISATMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 511/8; BL SYS in TRX 5,6OPEN
25-Jul-11EKO33PASAR WAJO1TAMPARAMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 128/25/11CLOSED
25-Jul-11ALFBIORNPINRANG1PinrangInnerMGCCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD77458/15/11CLOSED
25-Jul-11ALFBIORNPINRANG1NSDMCEMPAPSRMGTRX FAULTY76068/15/11CLOSED
25-Jul-11RENDRASIDRAP1ALAKUANGMDC7606, 7604TRX 1-11SDSR7/28/11CLOSED
25-Jul-11MULYADIFBULUKUMBAPASIRPUTIHMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 58/5/11CLOSED
26-Jul-11ANGGAJNPONTO1PETANAMDC2BL-TRX, BL-SYSTRX FAULTY7606TRX 1,2,5,68/8/11CLOSED
26-Jul-11ANGGAJNPONTO1BATANGMGC1BL-TRXTRX FAULTY7606TRX 4AGUNG2-AugDelete Create CI 1 trx 4, Repalce Module ECUG8/8/11CLOSED
26-Jul-11ANGGAJNPONTO1BINAMUMDC3BL-TRXTRX FAULTY7606TRX 11,128/8/11CLOSED
26-Jul-11ANGGAJNPONTO1CBTEMPOANGMGC1BL-TRX. BL-RSTTRX FAULTY7606TRX 1,28/8/11CLOSED
26-Jul-11ANGGAJNPONTO1CBTEMPOANGMGC3BL-TRXTRX FAULTY7606TRX 807/9; BL TRX in TRX 8OPEN
26-Jul-11ANGGAJNPONTO1PROTSIDENREMGC3BL-TRXTRX FAULTY7606TRX 128/15/11CLOSED
26-Jul-11ANGGAJNPONTO1PROTSIDENREMGC2BL-TRXCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 15,168/8/11CLOSED
26-Jul-11ANGGAJNPONTO1TOLOMGC2BL-TRXTRX FAULTY7606TRX 8AGUNG27-JulReplace ECUG ( cu 8 & 10 )8/8/11CLOSED
26-Jul-11ANGGAJNPONTO1ARUNGKEKEMGC1BL-TRXTRX FAULTY7606TRX 38/8/11CLOSED
26-Jul-11ANGGAJNPONTO1ARUNGKEKEMGC3BL-TRXTRX FAULTY7606-7745TRX 98/8/11CLOSED
26-Jul-11ANGGAJNPONTO1BONTORAMBAMGC1BL_TRX, BL-SYSCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TX 1,2,3AGUNG28-JulReplace CU trx 4,,Replace CU 2 for trx 2 Delate create CU 28/8/11CLOSED
26-Jul-11MULYADIBAUBAU1BUTON2MGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 11,128/5/11CLOSED
27-Jul-11ANGGAJNPONTO1ARUNGKEKEMDC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 8AGUNG29-Juldelete create CU 0 trx 3,repalce slot CU 1 to CU 3 rack 18/8/11CLOSED
27-Jul-11ANGGAJNPONTO1BINAMUMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 3,48/8/11CLOSED
27-Jul-11ANGGAJNPONTO1PROTSIDENREMDC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 118/8/11CLOSED
27-Jul-11INDRAPALOPO2SALULINOMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 712/9; SALULINOMGC2 still alarm 7745 in TRX 5,,7OPEN
27-Jul-11MULYADIFBULUKUMBABULUPODDOMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 1118/8; STILL ALARM 7745 IN TRX 11OPEN
27-Jul-11MULYADIFBULUKUMBASAMAENREMGC1CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 28/5/11CLOSED
27-Jul-11MULYADIFBULUKUMBASAMAENREMGC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 7,88/5/11CLOSED
27-Jul-11MULYADIFBULUKUMBASAMAENREMGC3CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 118/5/11CLOSED
27-Jul-11MULYADIFBULUKUMBAUJUNGBULUMDC2CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 88/23/11CLOSED
28-Jul-11RENDRATOBIA1MARIOMDCBL-RSL, BL DGN, BL TRXTRX 6-22AGUNG3-AugReplace ECUD trx 10,perftest All CU9/12/11CLOSED
28-Jul-11MULYADIBAUBAU1KABAWOMDC2BL-TRXTRX 107-Augreplace Cu,Moving Left COBA to right COBA,Alarm Clear8/23/11CLOSED
28-Jul-11MULYADIBAUBAU1MAWASANGKAMDCBL-TRXCHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD7745TRX 88/8; MAWASANGKAMDC4 alarm 7745 in TRX 1010/8; MAWAS
top related