Connected Component Workbench (CCW) Overview
AD13
Related Class
• AD14
• Solution Area 5
Micro800 Controller Family
Nano PLC Micro PLC
Micro810
Programmable
relay replacer and
timerMicro820
For simpler standalone
machines and remote
automation
Micro830
For standalone
machines with
motion
Pe
rfo
rma
nc
e/F
ea
ture
s
Micro850
For standalone
machines with motion
and more I/O and
Ethernet connectivity.
Local I/O
Analog I/O
Analog I/O
Each controller is cost and performance
optimized for specific applications
Micro810 Anatomy
Smart Relay Micro PLC – 12pts
Embedded 12/24/120/240V
power supply models
4-ch 0-10V
10bit analog input
(shared with DC inputs)
USB
(removable adapter)
4 Outputs
5/8A High current relays, 24VDC Source
Transistor models
LCD Display with
Memory Backup
function
(removable)
Embedded
12/24/120/240V
power supply models
DIN Rail or Panel
Mount
8 Inputs
12/24V Sink/Source,
120/240VAC
Micro810 Key Features
• High current relay outputs (8A) replaces the need for external relays to reduce cost and
panel space
– Can be used in places where more flexibility is required over a mechanical timer relay
• 4 channels of embedded analog (0-10V 10bit) for DC input models
– Applications include temperature control, compressor control
– Terminals shared with four of the 24VDC digital inputs (inputs 4-7)
• Optional LCD Display can be inserted into front of controller and removed under power
– Used to configure controller and to monitor I/O status
– Contains memory backup function
– Copy program to multiple machines. Makes “cloning” machines easy
– Load from memory backup to controller at power-up or at fault
– LCD instruction allows LCD Display and keypad to be used as simple text display
– Display and edit program variables
Micro810: Most Advanced Smart Relay Micro PLC and
Winner of the 2011 Control Design Readers’ Choice Award in the PLC Category
Micro810 Benefits
Just Configure, No Programming Required
• Micro810 has embedded smart relay function blocks configured from 1.5” LCD and
keypad
– No software or program download required
• Use in relay applications which require a small amount of logic (up to 4 function blocks)
– Applications include programmable timer, lighting control
• 8 Function blocks include Delay OFF/ON Timer, Time of Day, Time of Week, Time of
Year, CounterConfiguration by LCD
and Keypad
Monitoring
Smart Relay
Function
Blocks
Micro820 20pt Optimized for Smaller Standalone
Machines and Remote Automation Projects
Serial
Embedded 24VDC
Power Supply
RS232/485 Serial
Port (non-isolated)
Ethernet Port
Removable Terminal
Blocks option
Two
Plug-in Slots
5kHz Pulse Width Modulation*
(DC outputs)
4 (0-10V) Analog Input *
(Shared with DC Inputs)
microSD Card slot*
1 (0-10V) Analog
Output*
Embedded RTC*
10V Reference*
* Differences from
Micro830/Micro850
Uses of MicroSD Card
Memory back up and restore Data Logging
Power Up configurationEg Force Program mode, clear fault, ENET config, factory default serial comm
Recipe Management
Micro800 Remote LCD – Simple Display
IP65
Door Mount or DIN Rail
Build-in controller
system menu
(similar to Micro810)
4-color backlight
USB for program
download to controller
ASCII Text
RS232 connection to
Micro820
Configurable startup
message
Micro830 Anatomy
Block-style Micro PLC – 10/16/24/48pts
Serial
Embedded 24VDC
Power Supply
Optional AC Power
Supply (isolated)
attaches to left side
of controller
RS232/485 Serial
Port (non-isolated)
USB
Run/Program Switch
Two to Five
Plug-in Slots
DIN Rail or Panel
Mount
High Speed Inputs
(DC inputs)
Pulse Train Output
(DC outputs)
12/24V sink/src, 120VAC
input models
12/24V sink/src, relay output
models
Micro830 Features & Benefits
• Highly flexible and customizable - “Pay for only what you need”
– Plug-ins customize base unit with analog I/O, isolated serial ports, specialty modules and partner modules
• Easy to use and cost effective motion control via 100kHz Pulse Train Output
– PLC Open motion instruction reduces learning curve
• Embedded Serial Port for connection to HMI, bar code readers, printers
• Embedded USB for easy programming and configuration
10pt, 16pt 24pt 48pt
Up to 5 plug-ins
Removable Terminal
Block 24/48pt ModelRemovable Terminal
Block 24/48pt Models
2 Plug-ins 3 Plug-ins 5 Plug-ins
Micro800 Plug-In Modules
• Allows for highly customizable hardware configurations by extending the
controller’s I/O and communications
• Same set of modules for Micro820, Micro830 and Micro850
• Plugs onto the front of controller without increasing panel space
• Wide range of Plug-Ins available such as analog I/O, serial ports, etc.
• Specialty Modules from Encompass partners
Changes the “Personality” of the Base Unit Controller
12
Micro800 Plug-Ins
Category Catalog Number Description
Digital I/O 2080-IQ4 4-pt Digital Input, 12/24VDC, Sink/Source, Type3
2080-OB4 4-pt Digital Output, 12/24VDC, Source
2080-OV4 4-pt Digital Output, 12/24VDC, Sink
2080-OW4I 4-pt Relay Output, Individually Isolated, 2A
2080-IQ4OB4 8-pt Combo: 4-pt Digital Input, 12/24VDC, Sink/Source,
Type3, and 4-pt Digital Output, 12/24VDC, Source
2080-IQ4OV4 8-pt Combo: 4-pt Digital Input, 12/24VDC, Sink/Source,
Type3, and 4-pt Digital Output, 12/24VDC, Sink
Analog I/O
2080-IF4 4-ch Analog Input, 0-20mA, 0-10V, non-isolated 12-bit
2080-IF2 2-ch Analog Input, 0-20mA, 0-10V, non-isolated 12-bit
2080-OF2 2-ch Analog Output 0-20mA, 0-10V, non-isolated 12-bit
Specialty
2080-RTD2 2-ch RTD, non-isolated, ±1.0 °C
2080-TC2 2-ch TC, non-isolated, ±1.0 °C
2080-TRIMPOT6 6-ch Trimpot Analog Input
2080-MOT-HSC High Speed Counter, 250kHz, Differential Line Receiver, 1 Digital Output
Communications 2080-SERIALISOL RS232/485 isolated serial port
2080-DNET20 DeviceNet Scanner, 20 Nodes
Backup Memory 2080-MEMBAK-RTC Memory Backup and High Accuracy RTC
New
New
Plug-in Modules by Encompass
Partners
Encompass Partner Catalog # Function
Prosoft
(www.prosoft-technology.com)
ILX800-SMSG SMS
Spectrum Controls
(www.spectrumcontrols.com)
2080sc-IF4u Universal Analog Input
2080sc-OW2HC High Current Relay
2080sc-NTC 4 Channel Thermistor Input
2080sc-BACNet Ethernet and Serial Communication Module
Hardy
(www.hardysolutions.com)
HI2080-WS Weight Scale Interface
Micro850 Anatomy
Block-style Micro PLC – 24/48pts
15
Serial
Embedded 24VDC
Power Supply
Optional AC Power
Supply (isolated)
attaches to left side
of controller
RS232/485 Serial
Port (non-isolated)
USB
Run/Program Switch
Up to 4 additional
Expansion I/O blocks
DIN Rail or Panel
Mount
High Speed Inputs
(DC inputs/100khz)
Pulse Train Output
12/24V sink/src, 120VAC
input models
12/24V sink/src, relay output
2A/240vac models
Ethernet Port
Three or Five
Plug-in Slots
Micro850 Features & Benefits
� All the features of Micro830 with higher IO performance and more communication options
� Embedded Ethernet port for connect to existing network or faster peer to peer communication
� EtherNet/IP support for faster and simpler connection to HMI
� Modbus TCP protocol for communication to a wide range of 3rd party devices
� Higher performance IO support via 2085 Expansion IO
� Supports up to a total of 132 digital IO
� Higher density and performance analog IO
� Snaps firmly on right side of controller with removable terminal blocks for easy of installation
Micro850
2085 Expansion I/O Modules
Catalog # Description
2085-IA8 Micro800 8 Point 120 VAC Input Module
2085-IF4 Micro800 4 Point Analog Input Module
2085-IF8 Micro800 8 Point Analog Input Module
2085-IM8 Micro800 8 Point 220 VAC Input Module
2085-IQ16 Micro800 16 Point Digital Input Module
2085-IQ32T Micro800 32 Point Digital Input Module
2085-IRT4 Micro800 4 Channel TC/RTD Input Module
2085-OA8 Micro800 8 Point Triac Output Module
2085-OB16 Micro800 16 Point Source Output Module
2085-OF4 Micro800 4 Point Analog Output Module
2085-OV16 Micro800 16 Point Sink Output Module
2085-OW16 Micro800 16 Point Relay Output Module
2085-OW8 Micro800 8 Point Relay Output Module
2085-ECR* Micro800 End Cap Terminator
Comparison between;
Expansion I/O vs Plug-ins
Features Plug-In Expansion I/O
Terminal Block Non-removable Removable Terminal Block
Input Isolation Non-isolated analog inputs Isolated analog inputs
Analog resolution and
accuracy
12-bit resolution for Analog I/O
1% accuracy for Analog I/O
1degC accuracy for TC/RTD
14-bit resolution for Inputs
12-bit resolution for Output
0.1% accuracy for Analog I/O
0.5degC accuracy for TC/RTD
Filter times Fixed 50/60Hz filter Configurable filter times
I/O density 2pts to 8pts 4pts to 32pts
Footprint No increase in controller footprint Width of controller increases with
Expansion I/O
Different variety of modules Isolated Serial port, Trimpot,
Memory Back-up, RTC,
Encompass Products.
AC Input and Output modules.
Micro800 Communication Capabilities
Micro800
controller
USB
programing
port
Serial Port Ethernet DeviceNet
(via Plug-in)
CIP
Serial(Client/
Server)
Modbus
RTU(Master/
Slave)
ASCII/
Binary
EtherNet/IP(Client/server)
Modbus
TCP(Client/
Server)
DeviceNet
scanner
Micro810 Yes1 No No No No No No
Micro820 Yes2 Yes Yes Yes Yes Yes Yes
Micro830 Yes Yes Yes Yes No No Yes
Micro850 Yes Yes Yes Yes Yes Yes Yes
Note:
1: via USB adaptor (2080-USBADAPTER)
2: via Remote LCD (2080-REMLCD)
Micro830 and Micro850 Motion with
Connected Components Workbench
Support up to 3 axes with PTO• Compatible with Kinetix 3,
Kinetix 300, and 3rd party drives that support PTO
• Number of PTO axes depends on controller model
• Available on Micro830 and Micro850
PLCopen instructions• Program motion commands
via built-in PLCopen instructions
• IEC 61131-3 standard
Axis configuration in CCW• Create and configure axes in
CCW using 5 simple to use configuration screens
• Use the Axis Monitor to see important information about the status of axes
Connected Components Workbench
Overview
• Programming and configuration for RA Connected Components products:
– Micro800 PLC
– Guardmaster 440C Config. Safety relay
– PowerFlex drives (UDC)
– Kinetix 3 servo drives (UDC)
– PanelView Component terminals
– SMC-50 and Flex softstarters (UDC)
• Intuitive, graphical devices configuration
• Licensed version available for a small fee
• Localized in E, FIGS and Chinese
Micro800 and CCW network
connectivity
Micro800 with DNet Plug-inEtherNet/IP Modbus RTU
PC with CCW PVc
EtherNet/IP
DNETPTO
Kinetix 300 PF523Kinetix 3
Logix
Micro800
Stratix
2000
ModbusRTU
PF523
440C-CR30
CompactBlock
LDX
• Choice of network: Ethernet, DeviceNet, Serial.
• Choice of protocols: CIP, Modbus, ASCII.
• Choice of Micro800 connectivity to drives depends on performance requirements and number of drives: Hardwire I/O, Serial, Ethernet, DeviceNet.
• Connect to Compact Block LDX in DeviceNet network for more I/O.
• Guardmaster 440C-CR30 (configurable safety relay) on Modbus.
– Pl e SIL3 certified, 22 embedded safety I/O.
– Monitor diagnostics of safety component via PVc.
• One SW (CCW) to configure all essential devices for your machine application needs.