contents - old.mfa.gov.uaold.mfa.gov.ua/mediafiles/sites/jordan/files/commercial_offers/2017/... ·...
Post on 11-Aug-2020
8 Views
Preview:
TRANSCRIPT
CONTENTS
CABLES, WIRES, CORDS
Aluminium Control Cable АКВВГ (AKVVG)
Copper Control Cable КВВГ (KVVG)
Aluminium Control Cable АКВВГЄ (AKVVGE)
Copper Control Cable КВВГЭ (KVVGE)
Aluminium Control Cable АКВБбШв (AKVBbShv)
Copper Control Cable КВБбШв (KVBbShv)
Flexible Control Cable КГВВ (KGVV)
Aluminium Power Cable АВВГ (AVVG)
Copper Power Cable ВВГ (VVG)
Copper Power Cable ВВГз (VVGz)
Aluminium Power Cable АВБбШв (AVBbShv)
Copper Power Cable ВБбШв (VBbShv)
Aluminium Power Cable АПвВГ (APvVG)
Copper Power Cable ПвВГ (PvVG)
Power Cable with cross-linked polyethylene insulation АПвП, ПвП (APvP, PvP)
Power Cable with cross-linked polyethylene insulation АПвПу, ПвПу (APvPu, PvPu)
Power Cable with cross-linked polyethylene insulation АПвВ, ПвВ (APvV, PvV)
Power Cable with cross-linked polyethylene insulation АПвВнг-LS, ПвВнг-LS (APvVng-LS, PvVng-LS)
Power Cable with cross-linked polyethylene insulation АПвПг, ПвПг (APvPg, PvPg)
Power Cable with cross-linked polyethylene insulation АПвВг, ПвВг (APvVg, PvVg)
Power Cable with cross-linked polyethylene insulation АПвПга, ПвПга (APvPga, PvPga)
Power Cable with cross-linked polyethylene insulation АПвВга, ПвВга (APvVga, PvVga)
Insulated Wire for aerial power lines АВКПс (AVKPs)
Self-supporting Insulated Wire СИП-1, СИП-2 (SIP-1, SIP-2)
Self-supporting Insulated and Protected Wire СИП-3 (SIP-3)
Self-supporting Insulated Wire СИП-4 (SIP-4)
Self-supporting Insulated Wire for aerial lines 0,38 CAПт (SAPt)
Wire for electric installations ВВ (VV)
Wire for electric installations ВВП (VVP)
Wire for electric installations ВВПз (VVPz)
Aluminium Wire for electric installations АПВ (APV)
Copper Wire for electric installations ПВ (PV)
Aluminium Wire for electric installations АППВ (APPV)
Copper Wire for electric installations ППВ (PPV)
Winding Wire for submersible motors ПВДП (PVDP)
Hook-up Wire НВМ, НВ (NVM, NV)
Connecting Wire ПВСн (PVSn)
Wire for electric installations ПВСм, ПВСмп (PVSm, PVSmp)
Jumper Cord ШВПн (ShVPn)
Jumper Cord ШВВПн (ShVVPn)
CONTROL CABLES
АКВВГ (AKVVG) Cable with PVC insulation and PVC sheath A
APPLICATIONThe cable is designed for installation, repair and maintenance of electric distribution and control equipment, for fixed connection to electric devices, fixture assemblies of electric distributors with the rated AC voltage up to 660 V and frequency up to 100 Hz, or with DC up to 1,000 V. For installation in buildings, ducts and tunnels in conditions of corrosive medium. Mechanical impact on the cable is not allowed.
DESIGN- conductor: single aluminium wire with cross-section from 2.5 to 10 .0 mm2
- conductor insulation: polyvinylchloride (PVC). Insulated wires are twisted into a core.- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (AKВВГнг cable type) and in a low flammability low smoke PVC sheath (
AKВВГнг-LS cable type).
REQUIREMENTS COMPLIANCEТU U 05758730.013-2000
Operation temperature -40 °С ... +50 °С
Installation temperature -10 °С ... +50 °С
Minimum bending radius upon installation 6 cable diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size
4 х 2,55 х 2,57 х 2,510 х2,514 х 2,519 х 2,524 х 2,527 х 2,537 х 2,54 х 45 х 47 х 410 х 414 х 419 х 424 х 427 х 437 х 44 х 65 х 67 х 610 х 6
Outer dimensions of the cable, mm (reference)
10,07710,924
11,814,68015,94717,67021,03021,88824,77011,69212,73313,810
17,419,27221,39025,38
26,33829,39
12,77613,94815,160
19,6
Cable weight, kg/km (reference)
109,02127,39158,51217,48
276350,74453,74519,20689,50147,24180,50219,78302,44407,06520,15667,41759,43982,67179,25221,45272,02393,69
We keep the right to change this specification without notice
Cable size
14 х 619 х 624 х 627 х 637 х 64 х 105 х 107 х 1010 х 1014 х 1019 х 1024 х 1027 х 1037 х 10
Outer dimensions of the cable,mm (reference)
21,25624,04028,08029,10632,54015,57217,08019,04024,64026,81229,84035,44036,64041,060
Cable weight, kg/km (reference)
508,42676,76838,14952,35
1240,73265,42332,35430,09619,18808,28
1044,071331,971507,211976,61
CONTROL CABLES
АКВВГ with PVC insulation and PVC sheath
CONTROL CABLES
КВВГ (KVVG) Cable with PVC insulation and PVC sheath
APPLICATIONThe cable is designed for installation, repair and maintenance of electric distribution and control equipment, for fixed connection to electric devices, fixture assemblies of electric distributors with the rated AC voltage up to 660 V and frequency up to 100 Hz, or with DC up to 1,000 V. For installation in buildings, ducts and tunnels in conditions of corrosive medium. Mechanical impact on the cable is not allowed.
DESIGN- conductor: single copper wire with cross-sections 0.75, 1.0, 1.5, 2.5, 4.0 or 6.0 mm2
- conductor insulation: polyvinylchloride (PVC). Insulated wires are twisted into a core.- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (KВВГнг cable type) and in a low flammability low smoke PVC sheath (KВВГнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 05758730.013-2000
Operation temperature -40 °С ... +50 °С
Installation temperature -10 °С ... +50 °С
Minimum bending radius upon installation 6 cable diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size
4 х 0,755 х 0,757 х 0,7510 х 0,7514 х 0,7519 х 0,7524 х 0,7527 х 0,7537 х 0,754 х 15 х 17 х 110 х 114 х 119 х 124 х 127 х 137 х 14 х 1,55 х 1,57 х 1,510 х 1,5
Outer dimensions of the cable, mm (reference)
8,1148,2869,540
11,72013,07414,360
-16,90719,1608,0159,2919,990
12,32013,27514,65
17,09017,83020,2109,2649,966
10,74013,32
Cable weight, kg/km (reference)
88,6293,64
131,80179,72245,64311,27
-421,28564,0991,82
123,38153,58210,55271,96349,94439,11501,04672,60129,03151,86194,93269,14
CONTROL CABLES
КВВГ with PVC insulation and PVC sheath
We keep the right to change this specification without notice
Cable size
14 х 1,519 х 1,524 х 1,527 х 1,537 х 1,54 х 2,55 х 2,57 х 2,510 х2,514 х 2,519 х 2,524 х 2,527 х 2,537 х 2,54 х 45 х 47 х 410 х 414 х 419 х 424 х 4 27 х 437 х 44 х 65 х 67 х 610 х 614 х 619 х 624 х 627 х 637 х 6
Outer dimensions of the cable, mm (reference)
13,27515,9
19,02019,79721,99010,18211,04611,98014,96
14,37817,97021,39022,22725,19011,79712,85513,950
17,616,14221,76025,84026,77829,92013,02514,23215,48020,04021,85624,710
28,929,91433,490
Cable weight, kg/km (reference)
271,96456,87592,17672,32881,57175,08210,01275,56383,34351,98667,17854,18967,88
1305,84251,79304,49402,97564,27506,29
1024,031305,521474,681962,91340,10413,80553,32795,96
1076,991446,391812,792046,002738,77
CONTROL CABLES
АКВВГЭ (AKVVGE) Cable with PVC insulation and PVC sheath, screened
APPLICATIONThe cable is designed for installation, repair and maintenance of electric distribution and control equipment, for fixed connection to electric devices, fixture assemblies of electric distributors with the rated AC voltage up to 660 V and frequency up to 100 Hz, or with DC up to 1,000 V. For installation in buildings, ducts and tunnels in conditions of corrosive medium, if protection of circuits from the impact of external electromagnetic fields is needed. Mechanical impact on the cable is not allowed.
DESIGN- conductor: single aluminium wire with cross-section from 2.5 to 10.0 mm2
- conductor insulation: polyvinylchloride (PVC). Insulated wires are twisted into a core. зо лированные жилы - belt insulation: plastic or PVC tape- screen: aluminium foil. Copper wire Ø 0.4 mm is laid longitudinaly under the screen.- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (АКВВГЭнг cable type) and in a low flammability low smoke PVC sheath (АКВВГЭнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 05758730.013-2000
Operation temperature -40 °С ... +50 °С
Installation temperature -10 °С ... +50 °С
Minimum bending radius upon installation 6 cable diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size
4 х 2.55 х 2.57 х 2.510 х 2.514 х 2.519 х 2.527 х 2.537 х 2.54 х 45 х 47 х 410 х 414 х 419 х 427 х 437 х 44 х 65 х 67 х 610 х 614 х 619 х 6
Outer dimensions of the cable, mm (reference)
10,69711,54412,42015,34
16,53718,66
22,08824,97012,31213,35314,43
18,02019,93222,05026,57829,63013,39614,56815,78
-21,916
24,7
Cable weight, kg/km (reference)
130,80151,05184,11248,30309,38404,42541,55714,67172,59201,38249,82340,44450,29568,32788,45
1015,28207,00243,12305,06
-556,17729,67
CONTROL CABLES
АКВВГЭ with PVC insulation and PVC sheath, screened
We keep the right to change this specification without notice
Cable size
27 х 637 х 64 х 105 х 107 х 1010 х 1014 х 1019 х 1027 х 1037 х 10
Outer dimensions of the cable, mm (reference)
29,34632,78
16,19217,7
19,6625,26
27,43230,5
36,88041,3
Cable weight, kg/km (reference)
984,521276,94299,36355,27471,39672,56866,47
1111,231547,732022,34
CONTROL CABLES
КВВГЭ (KVVGE) Cable with PVC insulation and PVC sheath, screened
APPLICATIONThe cable is designed for installation, repair and maintenance of electric distribution and control equipment, for fixed connection to electric devices, fixture assemblies of electric distributors with the rated AC voltage up to 660 V and frequency up to 100 Hz, or with DC up to 1,000 V. For installation in buildings, ducts and tunnels in conditions of corrosive medium, if protection of circuits from the impact of external electromagnetic fields is needed. Mechanical impact on the cable is not allowed.
DESIGN- conductor: single copper wire with cross-sections 0.75, 1.0, 1.5, 2.5, 4.0 or 6.0 mm2
- conductor insulation: polyvinylchloride (PVC). Insulated wires are twisted into a core.- belt insulation: plastic or PVC tape- screen: aluminium foil. Copper wire Ø 0.4 mm is laid longitudinaly under the screen.- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (КВВГЭнг cable type) and in a low flammability low smoke PVC sheath (КВВГЭнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 05758730.013-2000
Operation temperature -40 °С ... +50 °С
Installation temperature -10 °С ... +50 °С
Minimum bending radius upon installation 6 cable diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size
4 х 0,755 х 0,757 х 0,7510 х 0,7514 х 0,7519 х 0,7527 х 0,7537 х 0,754 х 15 х 17 х 110 х 114 х 119 х 127 х 137 х 14 х 1,55 х 1,57 х 1,510 х 1,514 х 1,519 х 1,5
Outer dimensions of the cable, mm (reference)
9,410,010,712,813,715,017,619,89,7
10,411,113,414,415,818,920,910,311,111,914,415,517,0
Cable weight, kg/km (reference)
120138166222276344460608134155190255320403559719161188234317404514
CONTROL CABLES
КВВГЭ with PVC insulation and PVC sheath, screened
We keep the right to change this specification without notice
Cable size
27 х 1,537 х 1,54 х 2,55 х 2,57 х 2,510 х2,514 х 2,519 х 2,524 х 2,527 х 2,537 х 2,54 х 45 х 47 х 410 х 414 х 419 х 427 х 437 х 44 х 65 х 67 х 610 х 614 х 619 х 627 х 637 х 6
Outer dimensions of the cable, mm (reference)
20,422,611,312,213,116,017,319,422,925,812,9
-15,119,1
----
14,2-
16,621,2
-----
Cable weight, kg/km (reference)
716931212250314436565746
10191354295
-453645
----
387-
609868
-----
CONTROL CABLES
АКВБбШв (AKVBbShv) cablewith PVC insulation, screened,in PVC jacket
Cable size
4 х 2.55 х 2.57 х 2.510 х 2.514 х 2.519 х 2.527 х 2.537 х 2.54 х 45 x 47 х 410 х 414 x 419 x 427 x 437 x 44 х 65 x 67 х 610 х 614 x 619 x 6
Outer dimensions of the cable, mm (reference)
14,87715,724
16,619,55020,74722,47027,08829,27
16,49217,53318,6122,2
24,07226,59031,53934,59017,57618,74819,9624,4
26,45629,240
Cable weight, kg/km (reference)
337,33372,18420,34536,69618,51726,76
1002,911232,03406,96460,47520,70673,21814,24993,71
1333,971619,48460,07525,06599,21807,25979,25
1203,40
APPLICATIONThe cable is designed for installation, repair and maintenance of electric distribution and control equipment, for fixed connection to electric devices, fixture assemblies of electric distributors with the rated AC voltage up to 660 V and frequency up to 100 Hz, or with DC up to 1,000 V. For installation in buildings, ducts, tunnels and ground (trenches), also in conditions of corrosive medium and in places subjected to the impact of stray currents, provided the cableis not exposed to considerable tensions.
DESIGN- conductor: single aluminium wire with cross-section from 2.5 to 10.0 mm2
- conductor insulation: polyvinylchloride (PVC). Insulated wires are twisted into a core. - belt insulation: PVC tape- sheath: PVC- screen: flat steel tapes imposed spirally with overlap- jacket: PVC
OPTIONSIt is possible to manufacture cables with belt insulation and jacket made of low flammability PVC (АКВБбШвнг cable type) and with belt insulation and jacket made of low flammability low smoke PVC (АКВБбШвнг-LS cable type). пп
REQUIREMENTS COMPLIANCETU U 05758730.013-2000
Operation temperature -40 °С ... +50 °С
Installation temperature -10 °С ... +50 °С
Minimum bending radius upon installation 10 cable diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
CONTROL CABLES
АКВБбШв with PVC insulation, screened,
in PVC jacket
Cable size
27 x 637 x 64 х 105 x 107 х 1010 х 1014 x 1019 x 1027 х 10 37 х 10
Outer dimensions of the cable, mm (reference)
34,30638,14020,37221,88
23,84029,84032,01235,04042,24047,060
Cable weight, kg/km (reference)
1683,371978,01600,62696,89832,76
1159,061392,491690,072332,082940,59
We keep the right to change this specification without notice
Estimated weight of 1 km of the КВБбШв cable, kg (reference)
Estimated outer diameter of the КВБбШв cable, mm (reference)
Number of conductors
Number of conductors
Conductor cross-section, mm2
Conductor cross-section, mm2
457
101419242737
457
101419242737
0.7512,914
-14,8
-17,87419,160
---
0.75283,084
-376,53
-540,25631,66
---
1.514,06414,76615,54018,12019,178
20,723,82024,59727,190
1.012,81514,09114,79017,12018,07519,45
21,89022,63025,010
1.5347,29384,19442,78560,54663,95798,46994,45
1089,721367,37
1.0285,06340,18386,39490,05562,48667,21803,84880,16
1098,03
2.514,98215,48616,740
-20,94222,77026,59027,42730,390
4.016,59617,65518,750
22,424,40726,95031,04031,97835,120
2.5411,73463,99546,13
-852,58
1049,031327,731458,521856,94
4.0520,80594,71706,62938,92
1192,831505,131869,982058,182610,54
6.017,82619,03220,28
25,24027,05629,9134,1
35,11439,060
6.0625,77722,94886,73
1241,971560,051987,702439,612693,503496,34
We keep the right to change this specification without notice
CONTROL CABLES
КВБбШв (KVBbShv) cable with PVC insulation, screened,in PVC jacket
APPLICATIONThe cable is designed for installation, repair and maintenance of electric distribution and control equipment, for fixed connection to electric devices, fixture assemblies of electric distributors with the rated AC voltage up to 660 V and frequency up to 100 Hz, or with DC up to 1,000 V. For installation in buildings, ducts, tunnels and ground (trenches), also in conditions of corrosive medium and in places subjected to the impact of stray currents, provided the cable is not exposed to considerable tensions.
DESIGN- conductor: single copper wire with cross-section 0.75, 1.0, 1.5, 2.5, 4.0 or 6.0 mm2
- conductor insulation: PVC. Insulated wires are twisted into a core. - belt insulation: PVC- sheath: PVC- screen: flat steel tapes imposed spirally with overlap- jacket: PVC
OPTIONSIt is possible to manufacture cables with belt insulation and jacket made of low flammability PVC (КВБбШвнг cable type) and with belt insulation and jacket made of low flammability low smoke PVC (КВБбШвнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 05758730.013-2000
Operation temperature -40 °С ... +50 °С
Installation temperature -10 °С ... +50 °С
Minimum bending radius upon installation 10 cable diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
CONTROL CABLES
КГВВ with PVC insulation and PVC sheath
APPLICATIONThe cable is designed for fixed wiring of power circuits, control circuits and local lighting on machines and mechanisms with the rated AC voltage up to 660 V and frequency 50 Hz, or with DC voltage up to 1,000 V.
DESIGN- conductor: copper multiwire with cross-section 0.5, 0.75, 1.0, 1.5, 2.5, 4.0 or 6.0 mm2
- conductor insulation: PVC. Insulated wires are twisted into a core.Number of cores: 3, 4, 5, 7, 10, 14 or 19.- belt insulation: polyamide or polyethylene terephthalate tape- sheath: PVC
OPTIONSIt is possible to manufacture КГВВнг cable in a low flammability PVC sheath for installations in bunches of cables.
REQUIREMENTS COMPLIANCETU 16-505.665-74
Operation temperature -40 °С ... +50 °С
Installation temperature -15 °С ... +50 °С
Admissible continuous temperature on cable core + 70 °С
Minimum bending radius upon installation 7 cable diameters
Minimum bending radius during operation 15 cable diameters
Number of bends, not more 100
Minimum service life 8 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size
3 х 0,54 х 0,55 х 0,57 х 0,510 х 0,514 х 0,519 х 0,53 х 0,754 х 0,755 х 0,757 х 0,7510 х 0,7514 х 0,7519 х 0,753 х 14 х 15 х 17 х 110 х 114 х 119 х 13 х 1,5
Outer dimensions of the cable, mm (reference)
------
16,97,406
-9,277
-12,280
-17,440
7,68,224
-10,240
--
15,0709,635
Cable weight, kg/km (reference)
-------
69,88-
115,70-
193,04--
80,8398,18
-162,89
--
362,69121,18
CONTROL CABLES
КГВВ (KGVV) cable with PVC insulation and PVC sheath
Cable size
4 х 1,55 х 1,57 х 1,510 х 1,514 х 1,519 х 1,53 х 2,54 х 2,55 х 2,57 х 2,510 х2,514 х 2,519 х 2,53 х 44 х 45 х 47 х 410 х 414 х 419 х 43 х 164 х 165 х 167 х 1610 х 1614 х 1619 х 16
Outer dimensions of the cable, mm (reference)
10,43311,32312,24314,64016,59814,64010,60611,234
-13,270
--
20,470-
13,282------
20,870-----
Cable weight, kg/km (reference)
148,46181,39226,30292,09410,02306,26160,3
202,93-
314,26--
767,07-
288,47------
886,05-----
Cable size Outer dimensions of the cable, mm
(reference)
АВВГ cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
5,386,656,567,779,31
11,30511,94013,383
------
8,3610,3
11,3213,7415,62
1х2,5 (swc)1х4 (swc)1х6 (swc)1х10 (swc)1х16 (swc)1х251х351х501х701x951x1201x1501x1851x2402х2,5 (swc)2 x 4 (swc)2 x 6 (swc)2 x 10 (swc)2 x 16 (swc)
0.66 kV
35,3554,2655,3579,51
116,45169,0
200,84255,37
------
64,3898,65
119,48171,32223,65
1 kV
5,786,65
7,1607,979,51
11,50512,14013,58315,53
17,20618,78720,45823,80625,779
9,7611,5
12,52014,14016,020
1 kV
40,1953,9064,2382,89
120,50174,03206,16261,31
354,777445,30532,90643,04897,04
1044,4086,90
116,81138,94181,13231,79
POWER CABLES
АВВГ with PVC insulation and PVC sheath
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN- conductor: aluminium single- or multiwire with cross-section 2.5 ... 240.0 mm2
- conductor insulation: PVC- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (AВВГнг cable type) and in a low flammability low smoke PVC sheath (AВВГнг-LS cable type).
REQUIREMENTS COMPLIANCETU У 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature -50 °С ... +50 °С
Minimum installation temperature without prior heating 15 °С
Admissible continuous heating temperature of cores +70 °С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES
АВВГ (AVVG) cable with PVC insulation and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
АВВГ cable type with circular cores
АВВГ cable type with sector-shaped cores
Cable weight, kg/km (reference)
0.66 kV
20,01121,28
24,555------
9,40710,84811,94414,54616,56621,25722,62126,12311,79713,02615,94218,60723,81623,81625,34525,34528,82228,82228,82210,18211,79713,02615,94218,60723,81623,34528,82211,04612,85514,23217,49920,43726,22527,938
-
-----------
2 x 252 x 352 x 502 x 702 x 952 x 1202 x 1502 x 1852 х 240 3 x 2.5 (swc)3 x 4 (swc)3 x 6 (swc)3 x 10 (swc)3 x 16 (swc)3 x 253 x 353 x 503 x 4 + 1 x 2.5 (swc)3 x 6 + 1 x 4 (swc)3 x 10 + 1 x 6 (swc)3 x 16 + 1 x 10 (swc)3 x 25 + 1 x 103 x 25 + 1 x 163 x 35 + 1 x 163 х 35 + 1 х 253 x 50 + 1 x 163 x 50 + 1 x 253 х 50 + 1 х 354 x 2.54 x 44 x 64 x 104 x 164 x 254 x 354 x 505 х 2,55 х 45 х 6 5 х 10 5 х 165 х 255 х 355 х 50
3 x 703 x 953 х 1203 x 1503 х 1853 x 2403 х 70 + 1 х 25 3 x 70 + 1 x 353 х 70 + 1 х 503 х 95 + 1 х 353 x 95 + 1 x 50
0.66 kV
347,15412,38546,42
------
94,94121,91150,24221,04294,12460,10553,80736,19141,15177,12257,02366,09542,22562,02658,37697,70823,39862,71890,46109,99147,90184,09274,75385,89601,35725,45935,54133,44181,67227,90344,80502,34761,84921,14
1194,82
-----------
1 kV
20,41121,68
24,95528,85932,21234,97438,31744,61148,55910,26712,13713,23414,97616,99621,68722,08726,55313,24214,47216,42419,08924,29824,29825,82725,82729,30429,30429,30411,14613,24214,47216,42419,08924,29625,82729,30412,12614,47515,85218,43920,97726,76528,47832,373
29,53333,40536,43739,81445,95351,74532,61132,61132,61137,39038,896
1 kV
357,63423,41559,29752,38942,58
1120,751348,421867,472171,14105,84145,71175,98230,90305,18474,51494,25753,74168,70208,49275,82380,25559,78579,99677,1771,49
844,10884,41912,14127,30177,77216,55290,20400,46620,30745,52958,16155,43219,80269,09376,90504,15787,53939,78
1165,30
1041,681348,041617,841943,832510,803199,401172,611200,641246,351543,461597,44
Cable size Outer dimensions of the cable, mm
(reference)
АВВГ cable type with sector-shaped cores
АВВГ-П cable type
Cable weight, kg/km (reference)
0.66 kV
----------------------------
----------
3 х 95 + 1 х 703 x 120 + 1 x 353 х120 + 1 х 503 х 120 + 1 х 703 х 120 + 1 х 953 х 150 + 1 х 503 x 150 + 1 x 703 х 150 + 1 х 953 х 150 + 1 х 1203 х 185 + 1 х 503 х 185 + 1 х 953 x 185 + 1 x 953 х 185 + 1 х 1203 x 240 + 1 x 1203 х 240 + 1 х 1503 х 240 + 1 х 703 х 240 + 1 х 954 x 704 x 954 x 1204 x 1504 х 185 4 х 240 5 х 705 х 955 х 120 5 х 1505 х 1855 х 240
2 x 2.5 (swc)2 x 4 (swc)2 x 6 (swc)2 x 10 (swc)2 x 16 (swc)3 x 2.5 (swc)3 x 4 (swc)3 x 6 (swc)3 x 10 (swc)3 x 16 (swc)
0.66 kV
-----------------------------
61,0881,77
101,36150,85219,5186,81
117,88147,37222,19322,57
1 kV
37,3940,35640,35640,35640,35644,16744,16744,16744,16752,06852,06752,06852,06856,68156,68156,68156,68132,61137,39040,35644,16752,06856,68136,27541,32445,13149,49358,26466,961
----------
1 kV
1668,051785,351831,071909,941991,672159,752238,632320,362383,652758,982837,862919,582982,873669,813767,823526,783606,521322,371754,152066,202490,993247,894130,691644,952145,062573,453105,724040,415322,99
70,7686,50
119,59157,90227,91101,33143,14174,94232,91335,32
«П» - insulated conductors are arranged parallel(swc) – single-wire conductors
We keep the right to change this specification without notice
POWER CABLES
АВВГ with PVC insulation and PVC sheath
POWER CABLES
ВВГ (VVG) cable with PVC insulation and PVC sheath
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN- conductor: copper single- or multiwire with cross-section 1.5 ... 240.0 mm2
- conductor insulation: PVC- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (ВВГнг cable type) and in a low flammability low smoke PVC sheath (ВВГнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature -50 °С ... +50 °С
Minimum installation temperature without prior heating -15 °С
Admissible continuous heating temperature of cores +70 °С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size Outer dimensions of the cable, mm
(reference)
ВВГ cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
4,985,38
6,0506,567,779,65
11,30511,99713,448
----------
ВВГ 1 х 1,5 (swc)ВВГ 1х 2,5 (swc)ВВГ 1 х 4 (swc)ВВГ 1 х 6 (swc)ВВГ 1 х 10 (swc)ВВГ 1 х 16ВВГ 1 х 25 ВВГ 1 х 35ВВГ 1 х 50ВВГ 1 х 70ВВГ 1 х 95ВВГ 1 х 120ВВГ 1 х 150ВВГ 1 х 185 ВВГ 1 х 240ВВГ 1 х 300ВВГ 1 х 400ВВГ 1 х 500ВВГ 1 х 630
0.66 kV
38,7550,7570,2892,38
141,14220,50327,10421,15549,13
----------
1 kV
-6,0106,65
7,1607,97
-11,50512,19713,64815,34617,20619,04220,63022,42525,56230,90934,83738,02342,757
1 kV
-58,7578,52
101,26144,86
-335,15427,65556,63777,35
1038,591303,421583,561935,472544,743293,974325,875262,426569,06
POWER CABLES
ВВГ with PVC insulation and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
ВВГ cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
7,568,3610,3
11,3213,740
-20,011
-24,697
-------
9,40710,84811,94414,54617,29821,25722,74326,25410,18211,79713,02615,94219,42723,81623,81625,48325,48328,98128,98128,9819,218
10,18211,79713,02615,94219,42723,81625,48328,9819,966
11,04612,85514,23217,49921,35526,22528,09232,011
---
ВВГ 2 х 1,5 (swc)ВВГ 2 х 2,5 (swc)ВВГ 2 х 4 (swc)ВВГ 2 х 6 (swc)ВВГ 2 х 10 (swc)ВВГ 2 х 16 ВВГ 2 х 25 ВВГ 2 х 35 ВВГ 2 х 50ВВГ 2 х 70ВВГ 2 х 95ВВГ 2 х 120 ВВГ 2 х 150ВВГ 2 х 185ВВГ 2 х 240ВВГ 3 х 1,5 (swc) ВВГ 3 х 2,5 (swc) ВВГ 3 х 4 (swc) ВВГ 3 х 6 (swc) ВВГ 3 х 10 (swc) ВВГ 3 х 16 ВВГ 3 х 25 ВВГ 3 х 35 ВВГ 3 х 50 ВВГ 3 х 2,5 + 1 х 1,5 (swc)ВВГ 3 х 4 + 1 х 2,5 (swc)ВВГ 3 х 6 + 1 х 4 (swc) ВВГ 3 х 10 + 1 х 6 (swc)ВВГ 3 х 16 + 1 х 10 ВВГ 3 х 25 + 1 х 10 (swc)ВВГ 3 х 25 + 1 х 16 ВВГ 3 х 35 + 1 х 16 ВВГ 3 х 35 + 1 х 25ВВГ 3 х 50 + 1 х 16ВВГ 3 х 50 + 1 х 25ВВГ 3 х 50 + 1 х 35ВВГ 4 х 1,5 (swc) ВВГ 4 х 2,5 (swc) ВВГ 4 х 4 (swc) ВВГ 4 х 6 (swc) ВВГ 4 х 10 (swc) ВВГ 4 х 16 ВВГ 4 х 25 ВВГ 4 х 35 ВВГ 4 х 50 ВВГ 5 х 1,5 (swc) ВВГ 5 х 2,5 (swc) ВВГ 5х 4 (swc) ВВГ 5 х 6 (swc) ВВГ 5 х 10 (swc) ВВГ 5 х 16 ВВГ 5 х 25 ВВГ 5 х 35ВВГ 5 х 50ВВГ-П 2 х 1,5 (swc)ВВГ-П 2 х 2,5 (swc)ВВГ-П 2 х 4 (swc)
0.66 kV
71,2695,40
148,21194,07295,44
-665,56
-1145,27
-------
138,47196,27262,12407,22606,44937,72
1223,771629,54162,14231,01313,78480,49741,80
1081,891142,101432,311528,281820,031916,092034,11125,90172,04247,03333,26522,99802,01
1238,171618,282126,23152,90210,99305,37414,36655,51
1006,771557,882024,342681,53
61,9891,88
131,00
1 kV
8,369,7611,5
12,52014,140
-20,41121,79425,09728,49232,21235,48538,66142,25048,12335,48510,26712,13713,23414,97617,72821,68723,17326,69411,14613,24214,47216,42419,909
-24,29825,96525,965
-29,46329,46310,18211,14613,24214,47216,42419,90924,29825,96529,46311,04612,12614,47515,85218,43921,89526,76528,63232,551
---
1 kV
81,42117,92168,33215,68305,92
-682,34874,05
1160,041607,472144,952674,873253,223958,255192,06
-154,08224,14290,15420,72623,70959,79
1242,731651,91180,98260,85348,13500,29763,37
-1169,851455,751552,88
-1943,702006,09143,54191,23279,20368,28539,78824,64
1266,971643,292154,10175,12235,06346,90459,17692,58
1035,531595,102070,362718,47
75,52100,03145,84
POWER CABLES
ВВГ (VVG) cablewith PVC insulation and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
ВВГ cable type with circular cores
ВВГ cable type with sector-shaped cores
Cable weight, kg/km (reference)
0.66 kV
----------
-----------------------------------------
ВВГ-П 2 х 6 (swc)ВВГ-П 2 х 10 (swc)ВВГ-П 2 х 16 ВВГ-П 3 х 1,5 (swc)ВВГ-П 3 х 2,5 (swc)ВВГ-П 3 х 4 (swc)ВВГ-П 3 х 6 (swc)ВВГ-П 3 х 10 (swc)ВВГ-П 4 х 1,5 (swc)ВВГ-П 4 х 2,5 (swc)
ВВГ 3 х 70ВВГ 3 х 70 + 1 х 25 ВВГ 3 х 70 + 1 х 35ВВГ 3 х 70 + 1 х 50ВВГ 3 х 95ВВГ 3 х 95 + 1 х 35ВВГ 3 х 95 + 1 х 50ВВГ 3 х 95 + 1 х 70ВВГ 3 х 120ВВГ 3 х 120 + 1 х 35ВВГ 3 х 150 + 1 х 50ВВГ 3 х 120 + 1 х 70ВВГ 3 х 120 + 1 х 95ВВГ 3 х 150ВВГ 3 х 150 + 1 х 50ВВГ 3 х 150 + 1 х 70 ВВГ 3 х 150 + 1 х 95ВВГ 3 х 150 + 1 х 120ВВГ 3 х 185ВВГ 3 х 185 + 1 х 50ВВГ 3 х 185 + 1 х 70ВВГ 3 х 185 +1 х 95ВВГ 3 х 185 + 1 х 120ВВГ 3 х 240ВВГ 3 х 240 + 1 х 70ВВГ 3 х 240 + 1 х 95ВВГ 3 х 240 + 1 х 120ВВГ 3 х 240 + 1 х 150ВВГ 4 х 50ВВГ 4 х 70ВВГ 4 х 95ВВГ 4 х 120ВВГ 4 х 150ВВГ 4 х 185 ВВГ 4 х 240ВВГ 5 х 70ВВГ 5 х 95ВВГ 5 х 120ВВГ 5 х 150ВВГ 5 х 185ВВГ 5 х 240
0.66 kV
175,43274,11428,1297,22
133,02191,71258,47434,97126,45174,15
-----------------------------------------
1 kV
----------
29,13031,72731,72731,72732,82535,74135,74135,74136,00739,32539,32539,32539,32539,90442,91142,91142,91142,91145,95352,06852,06852,06852,06851,74556,68156,68156,68156,68126,39131,72735,74139,32542,91152,06856,68134,96939,67843,64448,51058,26466,961
1 kV
193,65281,82438,58110,53147,54216,98286,04418,79
--
2294,282576,872667,272787,273122,063517,213637,213844,013857,674235,244355,244562,044816,344750,725211,295418,105672,395908,325992,356537,306744,116988,407234,337786,698534,878789,169025,099298,802128,982983,854094,755039,476168,227889,73
10244,293714,575079,526253,487751,249842,92
12968,46
«П» - insulated conductors are arranged parallel(swc) – single-wire conductors
We keep the right to change this specification without notice
POWER CABLES
ВВГз with PVC insulation, filling and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
ВВГз cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
7,56--------
7,9479,407
10,84811,944
------
ВВГз 2 х 1,5 (swc)ВВГз 2 х 2,5 (swc)ВВГз 2 х 4 (swc)ВВГз 2 х 6 (swc)ВВГз 2 х 10 (swc)ВВГз 2 х 16 ВВГз 2 х 25 ВВГз 2 х 35 ВВГз 2 х 50ВВГз 3 х 1,5 (swc) ВВГз 3 х 2,5 (swc) ВВГз 3 х 4 (swc) ВВГз 3 х 6 (swc) ВВГз 3 х 10 (swc) ВВГз 3 х 16 ВВГз 3 х 25 ВВГз 3 х 35 ВВГз 3 х 50 ВВГз 3 х 2,5 + 1 х 1,5 (swc)
0.66 kV
86,59--------
104,15159,47221,02294,28
------
1 kV
8,36----
16,720,41121,79425,097
---
13,23414,97617,72821,68723,17326,69411,146
1 kV
100,76----
552,16845,99
1065,801415,46
---
329,20495,62706,16
1087,371392,321856,51199,49
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.For installations in dry and damp working areas, on special cable bridges, in blocks, and out-of-doors.For power supply of electricity generating plants which require sealing of the cables upon lead-in.
DESIGN- conductor: copper single- or multiwire with cross-section 1.5 ... 240.0 mm2
- conductor insulation: PVC- filling: PVC or unvulcanized rubber compound- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (ВВГзнг cable type) and in a low flammability low smoke PVC sheath (ВВГзнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature -50 °С ... +50 °С
Minimum installation temperature without prior heating -15°С
Admissible continuous heating temperature of cores +70°С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES
ВВГз (VVGz) cablewith PVC insulation, filling and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
ВВГз cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
------
25,483-------------
9,96611,04612,85514,232
--------
ВВГз 3 х 4 + 1 х 2,5 (swc)ВВГз 3 х 6 + 1 х 4 (swc) ВВГз 3 х 10 + 1 х 6 (swc)ВВГз 3 х 16 + 1 х 10 ВВГз 3 х 25 + 1 х 10 (swc)ВВГз 3 х 25 + 1 х 16 ВВГз 3 х 35 + 1 х 16 ВВГз 3 х 35 + 1 х 25ВВГз 3 х 50 + 1 х 16ВВГз 3 х 50 + 1 х 25ВВГз 3 х 50 + 1 х 35ВВГз 4 х 1,5 (swc) ВВГз 4 х 2,5 (swc) ВВГз 4 х 4 (swc) ВВГз 4 х 6 (swc) ВВГз 4 х 10 (swc) ВВГз 4 х 16 ВВГз 4 х 25 ВВГз 4 х 35 ВВГз 4 х 50 ВВГз 5 х 1,5 (swc) ВВГз 5 х 2,5 (swc) ВВГз 5х 4 (swc) ВВГз 5 х 6 (swc) ВВГз 5 х 10 (swc) ВВГз 5 х 16 ВВГз 5 х 25 ВВГз 5 х 35ВВГз 5 х 50ВВГз 5 х 95ВВГз 5 х 120ВВГз 5 х 150
0.66 kV
------
1603,69-------------
165,26227,48330,35446,81
--------
1 kV
13,242----
23,81625,96525,965
--
29,46310,18211,14613,24214,47216,42419,90924,29825,96529,463
---------
45,51746,83451,122
1 kV
290,79----
1294,561600,731697,86
--
2233,17157,50209,73309,14406,16592,23904,35
1438,231788,272353,17
---------
5220,796898,678456,29
We keep the right to change this specification without notice
АВБбШв with PVC insulation and PVC jacket, screened
POWER CABLES
Cable size Outer dimensions of the cable, mm
(reference)
АВБбШв cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
14,11016,10516,74
18,183----
13,76015,1
16,12018,54020,42024,41126,08028,965
---
1 х 16 (swc)1 х 25 1 х 351 х 501 х 701 х 951 х 1201 х 1502 x 2.52 x 4 (swc)2 x 62 x 10 (swc)2 x 16 (swc)2 x 252 x 352 x 502 x 702 x 952 x 120
0.66 kV
331,05422,54466,78549,46
----
283,85332,56373,31467,70556,11738,35851,48
1019,28---
1 kV
14,31016,30516,94018,38320,33022,00623,18725,25814,5616,3
17,3218,94020,82024,81126,48029,36533,25937,01239,374
1 kV
341,61434,61479,28554,67683,53808,20901,71
1066,32312,95377,28419,59482,72571,93756,14870,21
1039,281303,801590,611783,01
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN- conductor: aluminium single- or multiwire with cross-section 2.5 ... 240.0 mm2
- conductor insulation: PVC- belt insulation: PVC - screen: flat steel tapes imposed spirally with overlap- jacket: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (АВБбШвнг cable type) and in a low flammability low smoke PVC sheath (АВБбШвнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature -50 °С ... +50 °С
Minimum installation temperature without prior heating -15°С
Admissible continuous heating temperature of cores + 70°С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES
АВБбШв (AVBbShv) cablewith PVC insulation and PVC jacket, screened
АВБбШв cable type with sector-shaped cores
Cable size Outer dimensions of the cable, mm (reference)
АВБбШв cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
-14,20715,54716,74419,34621,36726,05727,42120,52316,59617,82620,74223,00728,21628,21629,74529,74533,22233,22233,22214,98216,59617,82620,74223,00728,21629,74533,22215,84617,65519,03222,29925,23730,62532,33836,633
-------------------
2 x 1503 x 2.5 (swc)3 x 4 (swc)3 x 63 x 10 (swc)3 x 16 (swc)3 x 253 x 353 x 503 x 4 + 1 x 2.53 x 6 + 1 x 43 x 10 + 1 x 63 x 16 + 1 x 10 (swc)3 x 25 + 1 x 103 x 25 + 1 x 163 x 35 + 1 x 163 х 35 + 1 х 253 x 50 + 1 x 163 x 50 + 1 x 253 х 50 + 1 х 354 х 2,5 (swc)4 х 4 (swc)4 х 6 (swc)4 х 10 (swc)4 х 16 (swc)4 х 254 х 354 х 505 х 2,5 (swc)5 х 4 (swc)5 х 6 (swc)5 х 10 (swc)5 х 16 (swc)5 х 25 5 х 355 х 50
3 х 703 x 70 + 1 x 253 х 70 + 1 х 353 х 70 + 1 х 503 х 953 х 95 + 1 х 353 х 95 + 1 х 503 х 95 + 1 х 703 х 120 3 х 120 + 1 х 353 х 120 + 1 х 503 х 120 + 1 х 703 х 1503 х 150 + 1 х 503 х150 + 1 х 703 х 150 + 1 х 953 х 1853 х 185 + 1 х 503 х 185 + 1 х 70
0.66 kV
-308,42366,52416,25532,88644,76898,75
1018,711237,41404,28459,79595,66731,61
1001,131020,931145,341184,661374,131413,461441,21341,61411,03466,76613,39751,42
1060,261212,411486,29381,92456,45533,72713,33907,85
1264,931455,661835,54
-------------------
1 kV
42,71715,06716,93818,03419,77621,79726,48727,85130,95318,04319,27221,22423,489
-28,69830,22730,22733,70433,70433,70415,94618,04319,27221,22423,48928,69830,22733,704
--------
33,93337,01137,01137,01138,20541,79041,79041,79040,83744,35644,35644,35644,21448,96748,96748,967
---
1 kV
2072,17341,92418,79462,65
551664,07921,43
1042,241262,85455,53519,36620,80754,59
-1047,741172,981213,291403,691444,001472,03380,56464,60526,98635,18774,80
1088,051241,321517,74
--------
1605,451792,861820,891866,602019,102250,162295,872374,752307,002504,112549,832628,702695,113037,643116,523198,24
---
АВБбШв cable type with sector-shaped cores
Cable size Outer dimensions of the cable, mm
(reference)Cable weight, kg/km
(reference)0.66 kV
-----------------
3 х 185 + 1 х 953 х 2403 х 240 + 1 х 703 х 240 + 1 х 953 х 240 + 1 х 1204 х 704 х 954 х 120 4 х 1504 х 185 4 х 2405 х 705 х 955 х 1205 х 1505 х 1855 х 240
0.66 kV
-----------------
1 kV
-----
37,01141,79044,75648,967
--
40,6754572449,53153,893
--
1 kV
-----
1975,472460,852827,463368,88
--
2331,142924,123421,744034,37
--
We keep the right to change this specification without notice
POWER CABLES
АВБбШв with PVC insulation and PVC jacket, screened
POWER CABLES
ВБбШв (VBbShv) cablewith PVC insulation and PVC jacket, screened
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN- conductor: copper single- or multiwire with cross-section 1.5 ... 240.0 mm2
- conductor insulation: PVC- belt insulation: PVC - screen: flat steel tapes imposed spirally with overlap- jacket: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (ВБбШвнг cable type) and in a low flammability low smoke PVC sheath (ВБбШвнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature -50 °С ... + 50 °С
Minimum installation temperature without prior heating -15 °С
Admissible continuous heating temperature of cores + 70 °С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size Outer dimensions of the cable, mm
(reference) ВБбШв cable type with circular cores
Cable weight, kg/km (reference)
1 х 16 -11 х 25 -11 х 35 -11 х 50 -11 х 70 -11 х 95 -11 х 120 -11 х 150 -12 х 2,5 (swc) -12 х 6 (swc) -12 х 10 (swc) -12 х 16 -12 х 25 -12 х 35 -12 х 50 -12 х 70 -12 х 95 -12 х 120 -12 х 150 -13 х 1,5 (swc) -1
14,6516,30516,99718,44820,14622,00623,44225,43014,56
17,32018,940
21,525,21126,59429,49732,89237,01239,88543,06114,207
453,39593,78701,91851,26
1104,561401,491673,072010,16347,73499,19613,27803,44
1108,991327,651647,092157,512799,113352,333989,68335,91
ВБбШв with PVC insulation and PVC jacket, screened
Cable size Outer dimensions of the cable, mm
(reference) ВБбШв cable type with circular cores
ВБбШв cable type with sector-shaped cores
Cable weight, kg/km (reference)
3 х 2,5 (swc) -13 х 4 (swc) -1 3 х 4 + 1 х 2,5 (swc) -13 х 6 (swc) -13 х 6 + 1 х 4 (swc) -13 х 10 (swc) -13 х 6 + 1 х 4 (swc) - 13 х 10 + 1 х 6 (swc) - 13 х 16 -13 х 16,0 + 1 х 10,0 - 13 х 25 -13 х 25 + 1 х 10 -13 х 25 + 1 х 16 - 13 х 35 -13 х 35 + 1 х 16 - 13 х 35 +1 х 25 -13 х 50 -13 х 50 + 1 х 25 -14 х 1,5 (swc) -14 х 2,5 (swc) -14 х 4 (swc) - 14 х 6 (swc) - 14 х 10 (swc) - 14 х 16 - 14 х 25 - 14 х 35 - 14 х 50 -15 х 2,5 (swc) -15 х 4 (swc) -15 х 6 (swc) -15 х 10 (swc) -15 х 16 -15 х 25 - 15 х 35 -15 х 50 -1
3 х 70 -13 х 70 + 1 х 25 -13 х 70 + 1 х 35 -13 х 95 -13 х 95 + 1 х 35 -13 х 95 + 1 х 50 -13 х 120 -13 х 120 + 1 х 70 -13 х 150 -13 х 150 + 1 х 70 -13 х 185 + 1 х 95 -14 х 70 -14 х 95 -14 х 120 -14 х 150 - 14 х 240 -15 х 70 -15 х 95 -15 х 120 -15 х 150 -1
15,06716,93818,04318,03419,27219,776
21,421,22422,52824,30926,48728,69828,69827,97330,36530,36531,09433,86314,98215,94618,04319,27221,22424,70928,69830,36533,86316,92619,27520,65222,83926,69531,16533,03233,951
33,5336,52736,52737,62540,94140,14140,40743,72544,30447,71153,81236,52740,14143,72547,71161,08139,36944,07848,44452,910
392,45497,98550,74579,87661,93744,32
725852,07
1000,841156,871411,301580,801642,081723,201958,902056,032168,592511,74380,20447,20569,08682,06891,55
1233,321739,202146,432722,15510,68660,76799,82
1058,851482
2113,092622,983072,08
2850,683215,543305,953781,934463,864313,574554,085321,025520,596289,978351,473622,534771,125798,457040,10
11305,394376,735828,327139,878682,52
(swc) – single-wire conductors «1» – rated AC voltage up to 1 kV«0.66» – rated AC voltage up to 0.66 kV
We keep the right to change this specification without notice
POWER CABLES
POWER CABLES
АПвВГ (APvVGP) cablewith PE insulation and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
АПвВГ cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
5,525,996,447,2
8,12010,90511,54
12,783----
9,2410,18011,080
12,614,44019,21120,480
1 х 2,5 (swc)1 х 4 (swc)1 х 6 (swc)1 х 10 (swc) 1 х 16 (swc)1 х 251 х 351 х 501 х 701 х 951 х 1201 х 1502 х 2,5 (swc)2 х 4 (swc)2 х 6 (swc)2 х 10 (swc)2 х 16 (swc)2 х 252 х 35
0.66 kV
34,5641,9549,9165,3087,21
152,25182,91228,39
----
74,8891,0
108,21141,20187,74312,74375,58
1 kV
5,525,996,447,2
8,12010,90511,54012,78314,93
16,40617,78720,058
9,2410,18011,080
12,614,44019,21120,480
1 kV
34,5641,9549,9165,3087,21
152,25182,91228,39319,56400,80474,31
390,97174,8891,0
108,2141,20
187,74312,74375,58
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN- conductor: aluminium single- or multiwire with cross-section 2.5 ... 240.0 mm2
- conductor insulation: vulcanized polyethylene- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (AПвВГнг cable type)and in a low flammability low smoke PVC sheath (АПвВГнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature - 50 °С ... + 70 °С
Minimum installation temperature without prior heating - 15 °С
Admissible continuous heating temperature of cores + 90 °С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size
Outer dimensions of the cable, mm (reference)
АПвВГ cable type with circular cores
АПвВГ cable type with sector-shaped cores
Cable weight, kg/km (reference)
0.66 kV
22,9659,708
10,71811,65211,68612,73613,32
14,56815,29816,78520,39722,45221,761
-24,38124,83327,37627,37610,51911,65212,73614,56816,78522,45224,38127,37611,42412,69313,90815,96
18,84425,14526,85830,213
--------------------
2 х 503 х 2,5 (swc)3 х 4 (swc)3 х 4 + 1 х 2,5 (swc)3 х 6 (ож)3 х 6 + 1 х 4 (swc)3 х 10 (swc)3 х10 + 1 х 6 (swc)3 х 16 (ож)3 х 16 + 1 х 10 (swc)3 х 25 3 х 25 + 1 х 163 х 353 х 35 + 1 х 163 х 35 + 1 х 253 х 503 х 50 + 1 х 253 х 50 + 1 х 354 х 2,5 (swc)4 х 4 (swc)4 х 6 (swc)4 х 10 (swc)4 х 16 (swc)4 х 254 х 354 х 505 х 2,5 (swc)5 х 4 (swc)5 х 6 (swc)5 х 10 (swc)5 х 16 (swc)5 х 255 х 355 х 50
3 х 703 х 70 + 1 х 25 3 х 70 + 1 х 353 х 953 х 95 + 1 х 503 х 1203 х 120 + 1 х 703 х 1503 х 150 + 1 х 704 х 704 х 954 х 1204 х 1504 х 1854 х 2405 х 705 х 955 х 1205 х 1505 х 240
0.66 kV
469,3089,30
110,79128,37134,02157,27179,14209,29243,66286,78411,09476,95501,21
-629,30655,91766,95793,51106,05133,25162,83220,65303,83516,10655,85830,84128,44163,13201,14275,01398,80678,21831,88
1058,83
--------------------
1 kV
22,9659,708
10,71811,65211,68612,73613,32
14,56815,29816,78520,39722,45221,76124,38124,38124,83327,37627,37610,51911,65212,73614,56816,78522,45224,38127,37611,42412,69313,90815,96018,84425,14526,858
-
28,23731,26131,26131,67735,59035,14139,00638,95043,26731,26135,59039,00643,26756,064
-34,86539,44443,32148,553
-
1 kV
469,3089,30
110,79128,37134,02157,27179,14209,29243,66286,78411,09476,95501,21590,15629,30655,91766,95793,51106,05133,25162,83220,65303,83516,10655,85830,84128,44163,13201,14275,01398,80678,21831,88
-
920,671028,711055,271183,301398,141448,221724,491785,272054,311158,661542,721862,872287,593125,96
-1451,991883,092279,872850,39
-
We keep the right to change this specification without notice
POWER CABLES
АПвВГ with PE insulation and PVC sheath
POWER CABLES
ПвВГ (PvVG) cablein PE insulation and PVC sheath
Cable size Outer dimensions of the cable, mm
(reference)
ПвВГ cable type with circular cores
Cable weight, kg/km (reference)
0.66 kV
5,586,0506,5607,37
9,25010,90511,59712,848
------
9,3610,3
11,32012,940
15,5
1 х 2,5 (swc)1 х 4 (swc)1 х 6 (swc)1 х 10 (swc)1 х 161 х 251 х 351 х 501 х 701 х 951 х 1201 х 1501 х 2401 х 6302 х 2,5 (swc)2 х 4 (swc)2 х 6 (swc)2 х 10 (swc)2 х 16
0.66 kV
50,8567,5889,21
131,04206,40308,10400,64518,62
------
107,85142,77187,68274,05404,80
1 kV
5,586,0506,5607,37
9,25010,90511,59712,84814,47616,40618,44221,95025,16240,757
9,3610,3
11,32012,940
15,5
1 kV
50,8567,5889,21
131,04206,40307,00399,44517,08736,73984,51
1244,171539,862477,076260,66107,85142,77187,68274,05406,17
APPLICATIONThe cable is designed for power transmission and distribution in fixed plants with the rated AC voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN- conductor: copper single- or multiwire with cross-section 2.5 ... 630.0 mm2
- conductor insulation: vulcanized polyethylene- sheath: PVC
OPTIONSIt is possible to manufacture cables in a low flammability PVC sheath (ПвВГнг cable type)and in a low flammability low smoke PVC sheath (ПвВГнг-LS cable type).
REQUIREMENTS COMPLIANCETU U 31.3-05758730-024-2002, GOST 16442-80, IEC 502
Operation temperature - 50 °С ... + 70 °С
Minimum installation temperature without prior heating - 15 °С
Admissible continuous heating temperature of cores + 90 °С
Minimum bending radius upon installation:
- single-core cable 10 cable diameters
- multi-core cable 7.5 cable diameters
Minimum service life 30 years
MAIN OPERATIONAL CHARACTERISTICS
Cable size Outer dimensions of the cable, mm
(reference)
ПвВГ cable type with circular cores
ПвВГ cable type with sector-shaped cores
Cable weight, kg/km (reference)
0.66 kV
19,21120,59423,097
----
9,83710,66410,84811,79711,94413,02613,68514,97816,43818,46320,39722,45222,28324,51924,51924,974
-27,535
9,710,66411,79713,02614,97818,46322,45224,51927,53510,50611,58612,85514,23216,41920,27525,145
------------
2 х 252 х 352 х 502 х 702 х 952 х 1202 х 1503 х 2,5 (swc)3 х 2,5 + 1 х 1,5 (swc)3 х 4 (swc)3 х 4 + 1 х 2,5 (swc)3 х 6 (swc)3 х 6 + 1 х 4 (swc)3 х 10 (swc)3 x 10 + 1 x 6 (swc)3 х 163 x 16 + 1 x 10 (swc)3 х 253 x 25 + 1 x 163 х 353 x 35 + 1 x 163 х 35 + 1 х 253 х 50 3 x 50 + 1 x 253 х 50 + 1 х 354 х 1,5 (swc)4 х 2,5 (swc)4 х 4 (swc)4 х 6 (swc)4 х 10 (swc)4 х 164 х 254 х 354 х 505 х 1,5 (swc)5 х 2,5 (swc)5 х 4 (swc)5 х 6 (swc)5 х 10 (swc)5 х 165 х 255 х 35
3 x 50 + 1 x 253 х 70 3 x 70 + 1 x 353 х 953 x 95 + 1 x 503 х 1203 x 120 + 1 x 703 х 1503 x 150 + 1 x 703 x 185 + 1 x 953 x 240 + 1 x 1204 х 50
0.66 kV
626,62814,19
1053,94----
138,42161,66188,09221,86252,53301,47377,43446,80566,20692,00881,91
1052,721178,671352,881444,021532,56
-1889,18126,02171,36236,14320,48484,51748,72
1143,861532,501999,47153,19210,28291,75393,38605,64938,65
1462,32
------------
1 kV
19,21120,59423,09727,29230,61234,285
41,39,837
10,66410,84811,79711,94413,02613,68514,97816,43818,46320,39722,45221,88324,51924,51924,97427,53527,535
9,710,66411,79713,02614,97818,46322,45224,51927,53510,50611,58612,85514,23216,41920,27525,14527,012
-27,83430,37731,09733,54134,71137,79539,04042,011
---
1 kV
628,28815,94
1055,571527,152032,842560,833159,83138,42161,66188,09221,86252,53301,47377,43446,80567,07693,66882,73
1053,311159,581354,141444,861533,621801,281889,65126,02171,36236,14320,48484,51749,70
1144,031533,241999,60153,19210,28291,75393,38605,64939,35
1462,541927,68
-2175,332527,742943,913401,373681,894359,674569,035235,38
---
POWER CABLES
ПвВГ in PE insulation and PVC sheath
POWER CABLES
ПвВГ (PvVG) cablein PE insulation and PVC sheath
We keep the right to change this specification without notice
Cable size Outer dimensions of the cable, mm
(reference)
ПвВГ cable type with sector-shaped cores
Cable weight, kg/km (reference)
0.66 kV
-------------
4 х 704 х 954 х 1204 х 1504 х 1854 х 2405 x 505 x 705 x 955 x 1205 x 1505 x 1855 x 240
0.66 kV
-------------
1 kV
30,37733,54137,97542,01156,61855,781
-------
1 kV
-2834,603842,644818,305971,677633,329898,09
------
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвП, ПвП for 10 kV voltage Single-core power cables with copper and aluminium conductors,
with cross-linked PE insulation and PE sheath
APPLICATIONThe cables are designed for power transmission and distribution in fixed plants with 10 kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.For installation in ground (trenches), provided the cable is protected from mechanical impacts, regardless of the degree of the ground corrosive activity.Aerial installation of these cables is allowed, including laying in cable structures, with additional fire protection, for example application of flame-retardant coats. For installation on routes with unlimited difference of elevation.
DESIGN1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 630.0 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor.3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation.5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Sheath: polyethylene compound.
OPTIONSIt is possible to manufacture cables with sealing elements (АПвПг, ПвПг), with an additionalalumopolymer tape over the sealed screen (АПвП2г, ПвП2г), with additional sealing of conductors with waterblocking yarns (АПвП2гж, ПвП2гж).
REQUIREMENTS COMPLIANCETU 16.К71-335-2004
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of the copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame-resistance + 400 °С
Admissible heating temperature of cores in emergency operation +130 °C
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life period
Installation of the cable without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвП, ПвП (APvP, PvP) cables for 10 kV voltageSingle-core power cables with copper and aluminium conductors, with cross-linked PE insulation and PE sheath
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95630/35630/50630/70630/95
507095
120150185240300400500630
Aluminium conductor
Aluminium conductor
170210253288322364422476541614695
triangle
195240263298329371426477525587653
in-planeAluminium conductor
185230300346392450531609710822954
triangle
225280349403452518607693787900
1026
in-plane
Copper conductor
225275326370413466537604677759848
triangle
250310336380416466531590633697762
in-planeCopper conductor
240300387445503577677776891
10251166
triangle
290360448515574654762865959
10811213
in-planeCopper conductor
659748
--
853--
957---
1153--
1286--
1486--
1701---
2136---
2471-------
25,326,8
--
28,4--
30,2---
31,8--
33,6--
35,8--
38,3---
41,9---
44,7-------
9681181
--
1441--
1699---
2081--
2431--
2972--
3558---
4612---
5566-------
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWABLE CURRENT LOAD, А
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвПу, ПвПу for 10 kV voltage Single-core power cables with copper and aluminium conductors,
with cross-linked PE insulation and reinforced PE sheath
APPLICATIONThe cables are designed for power transmission and distribution in fixed plants with 10 kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.For installation in ground (trenches), provided the cable is protected from mechanical impacts, regardless of the degree of the ground corrosive activity.For installation along routes with complicated configuration. Aerial installation of these cables is allowed, including laying in cable structures, with additional fire protection, for example application of flame-retardant coats. For installation on routes with unlimited difference of elevation.
DESIGN1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 630.0 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor. 3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation.5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Sheath: polyethylene compound.
OPTIONSIt is possible to manufacture cables with sealing elements (АПвПуг, ПвПуг), with an additional alumopolymer tape over the sealed screen (АПвПу2г, ПвПу2г), with additional sealing of conductors with waterblocking yarns (АПвПу2гж, ПвПу2гж).
REQUIREMENTS COMPLIANCETU 16.К71-335-2004
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of the copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame-resistance + 400 °С
Admissible heating temperature of cores in emergency operation +130 °С
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life period
Installation of the cable without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвПу, ПвПу (APvPu, PvPu) cables for 10 kV voltageSingle-core power cables with copper and aluminium conductors, with cross-linked PE insulation and reinforced PE sheath
Nominal cross-section of conductor/screen
Nominal conductor cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95630/35630/50630/70630/95
507095
120150185240300400500630
Aluminium conductor
Aluminium conductor
170210253288322364422476541614695
triangle in-plane triangle
195240263298329371426477525587653
Aluminium conductor
185230300346392450531609710822954
triangle
225280349403452518607693787900
1026
in-plane
Copper conductor
225275326370413466537604677759848
250310336380416466531590633697762
in-planeCopper conductor
240300387445503577677776891
10251166
triangle
290360448515574654762865959
10811213
in-planeCopper conductor
697789
--
896--
1003---
1201--
1337--
1541--
1759---
2200---
2539---
2999---
26,327,8
--
29,4--
31,2---
32,8--
34,6--
36,8--
39,3---
42,9---
45,7---
49,3---
10071222
--
1485--
1746---
2130--
2482--
3026--
3616---
4676---
5634---
6898---
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWABLE CURRENT LOAD, А
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВ, ПвВ for 10 kV voltage Single-core power cables with copper and aluminium conductors,
with cross-linked PE insulation and PVC sheath
APPLICATIONThe cables are designed for power transmission and distribution in fixed plants with 10 kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.For single installation in cable structures and working areas. It is also possible to install these cables in dry grounds (sand, argillo-arenaceous and normal soils with humidity not less than 14%). For installation on routes with unlimited difference of elevation.
DESIGN1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 630.0 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor. 3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation.5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Sheath: PVC.
REQUIREMENTS COMPLIANCETU 16.К71-335-2004
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of the copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame-resistance + 400 °С
Admissible heating temperature of cores in emergency operation +130 °С
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life period
Installation of the cable without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
ОСНОВНЫЕ ТЕХНИКО
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВ, ПвВ (APvV, PvV) cables for 10 kV voltageSingle-core power cables with copper and aluminium conductors,with cross-linked PE insulation and PVC sheath
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95630/35630/50630/70630/95
507095
120150185240300400500630
Aluminium conductor
Aluminium conductor
170210253288322364422476541614695
triangle
195240263298329371426477525587653
in-planeAluminium conductor
185230300346392450531609710822954
triangle
225280349403452518607693787900
1026
in-plane
Copper conductor
225275326370413466537604677759848
triangle
250310336380416466531590633697762
in-planeCopper conductor
240300387445503577677776891
10251166
triangle
290360448515574654762865959
10811213
in-planeCopper conductor
787885
--
999--
1113---
1318--
1461--
1674--
1903---
2358---
2708---
3203---
25,326,8
--
28,4--
30,2---
31,8--
33,6--
35,8--
38,3---
41,9---
44,7---
48,3---
10961318
--
1587--
1856---
2246--
2606--
3159--
3760---
4834---
5803---
7102---
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWABLE CURRENT LOAD, А
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВнг-LS, ПвВнг-LS for 10 kV voltage Single-core power cables with copper and aluminium conductors,
with cross-linked PE insulation and flame-retardant PVC sheath
APPLICATIONThe cables are designed for power transmission and distribution in fixed plants with 10 kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.For group installation of cable lines in cable structures and working areas. These cable can also be installed in explosive zones of B-I, B-Ia (ПвВнг-LS), В-Iб, B-Iг, В-II, В-IIа (АПвВнг-LS) classes.For installation on routes with unlimited difference of elevation.
DESIGN
1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 630.0 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor.3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation.5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Separating layer: at least one coat of glass fiber tape (nominal thickness 0.2 mm) with at least 30% overlap.8. Inner sheath: flame-retardant PVC. 9. Thermal barrier: copper or aluminium tape (nominal thickness 0.15 mm) with at least 30% overlap.10. Sheath: flame-retardant PVC.
REQUIREMENTS COMPLIANCETU 16.К71-335-2004
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of the copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame-resistance + 400 °С
Admissible heating temperature of cores in emergency operation +130 °С
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life period
Installation of the cables without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВнг-LS, ПвВнг-LS (APvVng, PvVng) for 10 kV voltageSingle-core power cables with copper and aluminium conductors,with cross-linked PE insulation and flame-retardant PVC sheath
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95630/35630/50630/70630/95
507095
120150185240300400500630
Aluminium conductor
Aluminium conductor
170210253288322364422476541614695
triangle
195240263298329371426477525587653
in-planeAluminium conductor
185230300346392450531609710822954
triangle
225280349403452518607693787900
1026
in-plane
Copper conductor
225275326370413466537604677759848
triangle
250310336380416466531590633697762
in-planeCopper conductor
240300387445503577677776891
10251166
triangle
290360448515574654762865959
10811213
in-planeCopper conductor
697789
--
896--
1003---
1201--
1337--
1541--
1759---
2200---
2539---
2999---
26,327,8
--
29,4--
31,2---
32,8--
34,6--
36,8--
39,3---
42,9---
45,7---
49,3---
10071222
--
1485--
1746---
2130--
2482--
3026--
3616---
4676---
5634---
6898---
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWABLE CURRENT LOAD, А
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвПг, ПвПг for 10 kV voltage Single-core power cables with copper and aluminium conductors,
with cross-linked PE insulation and PE sheath
APPLICATIONThe cables are designed for power transmission and distribution in fixed plants with Uo/U(Um) 6/10(12) kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral. Uo – rated voltage between the conductor and earth (insulated neutral) for which the cable is designed for;U – rated voltage between conductors;Um – maximum main voltage value allowing usage of the cable. For installation in grounds (tranches) with high corrosive activity and heightened humidity.Installation is also allowed:– on routes with unlimited difference of elevation;– in the air with protection against solar radiation;– in cable structures with additional fireproofing.
DESIGN
1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 625 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor.3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation.5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Separating layer: water-blocking tape. 8. Sheath: polyethylene compound.
REQUIREMENTS COMPLIANCETU U 31.3-20006134-041:2008
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of the copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame-resistance + 400 °С
Admissible heating temperature of cores in emergency operation +130 °С
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life period
Installation of the cables without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвПг, ПвПг (APvPg, PvPg) cables for 10 kV voltageSingle-core power cables with copper and aluminium conductors,with cross-linked PE insulation and PE sheath
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95625/35625/50625/70625/95
507095
120150185240300400500625
Aluminium conductor
Aluminium conductor
177217260296331375436492561639722
triangle
187229274312349395459497562632696
in-planeAluminium conductor
185233284328370424504580676784915
triangle
211263322372421484575674770868
1050
in-plane
Copper conductor
229280335381426483561635722823930
triangle
241295354402448508591640725814897
in-planeCopper conductor
242300369423473543643740842953
1113
triangle
288355428496558631742840934
10471150
in-planeCopper conductor
648,30786,70865,92972,63873,37952,71
1059,58992,17
1071,721178,881313,061188,891256,281425,001334,221441,911570,981561,741669,941799,62
----------------
282929293131313333333334343436363638383840404040444444444747474750505050
939,451178,141257,241363,781448,901528,171634,941707,471786,891893,882022,122074,182181,382309,88
----------------------
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWABLE CURRENT LOAD, А
* Technical characteristics of the ПвПг, АПвПг cables are analogue to those of the ПвЭгП, АПвЭгП cables
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВг, ПвВг for 10 kV voltage Single-core power cables with copper and aluminium conductors, with cross-linked PE insulation and PVC sheathата
Environment temperature during operation +50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame resistance + 400 °С
Admissible temperature of cores in emergency operation + 130 °C
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life
Installation of the cables without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation not less than 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
ПРИМЕНЕНИЕ
The cables are designed for power transmission and distribution in fixed plants with Uo/U(Um) 6/10(12) kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.Uo – rated voltage between the conductor and earth (insulated neutral) for which the cable is designed for;U – rated voltage between conductors;Um – maximum main voltage value allowing usage of the cable. For instullation in dry grounds, premises, ducts and tunnels.Installation is also allowed on routes with unlimited difference of elevation.
DESIGN1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 625 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor. 3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation.5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Separating layer: water-blocking tape.8. Sheath: PVC
REQUIREMENTS COMPLIANCEТU U 31.3-20006134-041:2008
OPTIONSIt is possible to manufacture cables in fire-retardant PVC sheath (АПвВгнг, ПвВгнг cabletypes) and in fire-retardant, low smoke and low corrosion-active gases emission PVC sheath (АПвВгнгд, ПвВгнгд cable types)
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВг (APvVg), ПвВг (PvVg) for 10 kV voltageSingle-core power cables with copper and aluminium conductors,with cross-linked PE insulation and PVC sheathтик ата
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95625/35625/50625/70625/95
507095120150185240300400500625
Aluminium conductor
Aluminium conductor
177217260296331375436492561639722
triangle
187229274312349395459497562632696
in-plane Aluminium conductor
185233284328370424504580676784915
triangle
2112633223724214845756747708681050
in-plane
Copper conductor
229280335381426483561635722823930
triangle
241295354402448508591640725814897
in-plane Copper conductor
2423003694234735436437408429531113
triangle
28835542849655863174284093410471150
in-plane Copper conductor
735,06884,69965,561072,27975,541056,521163,391101,211182,401289,561419,501304,731412,111542,331456,431564,121694,691694,101802,301933,481910,38
--
2328,01--
2405,94---------
282929293131313333333334343436363638383840404040444444444747474750505050
1026,461271,481352,231458,781548,441629,361736,121812,371893,442000,422161,892185,902293,112423,10
-2737,012867,58
-------------------
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWED CURRENT LOAD, A
* Technical characteristics of the ПвПг (PvPg), АПвПг (APvPg) cables are analogue to those of ПвЭгП (PvEgP), АПвЭгП (APvEgP) cables
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвПга, ПвПга for 10 kV voltage in PE sheath with lengthwise and crosswise water-blocking sealing
nal a nd lateral encapsulation to prevent mois Single-core power cables with copper and aluminium conductors, cross-linked PE insulation,
в обо лочке из полиэтилена с продольной и поперечнойгерметизацией от распространения влаги
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90 °С
Admissible maximum heating temperature of cores during faults + 250 °С
Admissible maximum heating temperature of copper screen during faults + 350 °С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame resistance + 400 °С
Admissible temperature of cores in emergency operation + 130 °С
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life
Installation of the cables without prior heating should be carried out at a temperature not less than - 15 °С
Minimum bending radius upon installation not less than 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
APPLICATION The cables are designed for power transmission and distribution in fixed plants with Uo/U(Um) 6/10(12) kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.Uo – rated voltage between the conductor and earth (insulated neutral) for which the cableis designed for;U – rated voltage between conductors;Um – maximum main voltage value allowing usage of the cable. For installation in grounds with hightened humidity and in damp or partially flooded premises.Installation is also allowed:– on routes with unlimited difference of elevation;– in the air with protection against solar radiation;– in cable structures with additional fireproofing.
DESIGN1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 625 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor.3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation. 5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Separating layer: water-blocking tape.8. Aluminium polyethylene tape (nominal thickness no less than 0.1 mm).9. Sheath: polyethylene compound.
REQUIREMENTS COMPLIANCEТU U 31.3-20006134-041:2008
OPTIONSIt is possible to manufacture cables with reinforced sheath (АПвПгау, ПвПгау cable types)
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвПга (APvPga), ПвПга (PvPga) for 10 kV voltage
Single-core power cables with copper and aluminium conductors, cross-linked PE insulation, in PE sheath with lengthwise and crosswise water-blocking sealing герметизацией от распространения влаги
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95625/35625/50625/70625/95
507095
120150185240300400500625
Aluminium conductor
Aluminium conductor
177217260296331375436492561639722
triangle
187229274312349395459497562632696
in-plane Aluminium conductor
185233284328370424504580676784915
triangle
211263322372421484575674770868
1050
in-plane
Copper conductor
229280335381426483561635722823930
triangle
241295354402448508591640725814897
in-plane Copper conductor
242300369423473543643740842953
1113
triangle
288355428496558631742840934
10471150
in-plane Copper conductor
685,66828,39907,62
1014,32912,90994,40
1101,281038,201117,751224,901355,521234,911342,301471,021386,741494,421623,501616,421724,621854,31
-1937,60
--------------
282929293131313333333334343436363638383840404040444444444747474750505050
976,811217,671296,771403,301490,601572,031678,801751,331830,751937,732068,142120,202227,402355,911494,42
---------------------
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWED CURRENT LOAD, A
* Technical characteristics of the ПвПг (PvPg) and АПвПг (APvPg) cables are analogue to those of ПвЭгП (PvEgP) and АПвЭгП (APvEgP) types
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
АПвВга, ПвВга for 10 kV voltage Single-core power cables with copper and aluminium conductors, cross-linked PE insulation,
in PVC sheath with lengthwise and crosswise water-blocking sealing
Environment temperature during operation + 50 °C ... - 60 °С
Admissible continuous heating temperature of cores + 90°С
Admissible maximum heating temperature of cores during faults +250°С
Admissible maximum heating temperature of copper screen during faults +350°С
Admissible maximum heating temperature of cores during faults (not exceeding 5 seconds) for the cables' flame resistance +400°С
Admissible temperature of cores in emergency operation +130°С
Emergency operation time should not exceed 8 hours per day and 1,000 hours during the cables' service life
Installation of the cables without prior heating should be carried out at a temperature not less than -15°С
Minimum bending radius upon installation not less than 20 cable diameters
Warranty lifetime 5 years from the date of installation, but not more than 8 years from the production date
MAIN OPERATIONAL CHARACTERISTICS
APPLICATIONThe cables are designed for power transmission and distribution in fixed plants with Uo/U(Um) 6/10(12) kV rated AC voltage, frequency 50 Hz, for networks with earthed and insulated neutral.Uo – rated voltage between the conductor and earth (insulated neutral) for which the cableis designed for;U – rated voltage between conductors;Um – maximum main voltage value allowing usage of the cable. For instullation in dry grounds, premises, ducts and tunnels.Installation is also allowed on routes with unlimited difference of elevation.
DESIGN1. Conductor: compacted circular copper or aluminium multiwire with cross-section 50 ... 625 mm2.2. Semiconducting screen: cross-linked polyethylene compound along the conductor. 3. Insulation: cross-linked polyethylene.4. Semiconducting screen: cross-linked polyethylene compound along the insulation. 5. A layer of a semiconducting tape.6. Screen: copper wires fastened with a copper tape.7. Separating layer: water-blocking tape.8. Aluminium polyethylene tape (nominal thickness no less than 0.1 mm).9. Sheath: PVC.
REQUIREMENTS COMPLIANCEТU U 31.3-20006134-041:2008
OPTIONSIt is possible to manufacture cables in fire-retardant PVC sheath (АПвВганг (APvVgang), ПвВганг (PvVgang) cable types) and in fire-retardant, low smoke and low corrosion-active gases emission PVC sheath (АПвВгангд (APvVgangd), ПвВгангд (PvVgangd) cable types)
POWER CABLES WITH CROSS-LINKED POLYETHYLENE INSULATION
Nominal cross-section of conductor/screen
Nominal conductor
cross-section
Outer diameter, mm
Ground installation Aerial installation
Weight of 1 km of the cable, kg
50/1670/1670/2570/3595/1695/2595/35
120/16120/25120/35120/50150/25150/35150/50185/25185/35185/50240/25240/35240/50300/25300/35300/50300/70400/35400/50400/70400/95500/35500/50500/70500/95625/35625/50625/70625/95
507095
120150185240300400500625
Aluminium conductor
Aluminium conductor
177217260296331375436492561639722
triangle
187229274312349395459497562632696
in-plane Aluminium conductor
185233284328370424504580676784915
triangle
211263322372421484575674770868
1050
in-plane
Copper conductor
229280335381426483561635722823930
triangle
241295354402448508591640725814897
in-plane Copper conductor
242300369423473543643740842953
1113
triangle
288355428496558631742840934
10471150
in-plane Copper conductor
773,77927,73
1008,591115,301020,741101,721208,601148,581229,771336,931466,871354,261461,651591,861508,131615,811748,551752,291860,491991,67
----------------
282929293131313333333334343436363638383840404040444444444747474750505050
1065,161312,351393,101499,631591,481674,561781,321857,571938,642045,622177,522233,272340,472470,47
----------------------
OUTER DIAMETER AND ESTIMATED WEIGHT OF THE CABLES
ALLOWED CURRENT LOAD, A
АПвВга (APvVga), ПвВга (PvVga) for 10 kV voltageSingle-core power cables with copper and aluminium conductors, cross-linked PE insulation, in PVC sheath with lengthwise and crosswise water-blocking sealing
Wire size
АВКАПс 16/16
Rated outer diameter of the wire, mm (reference)
11,5
Wire weight, kg/km (reference)
158
APPLICATION The wire is designed for power transmission and distribution in power and lighting networks with the nominal AC voltage up to 380 V, frequency 50 Hz. Outdoor installation for lead-in into buildings and utility structures in ice coating areas 1 and 2.
DESIGN 1. Conductor: inner single aluminium wire with cross-section 16.0 mm2
2. Inner conductor insulation: PVC 3. Outer concentric conductor: aluminium wires4. Sheath: black cross-linked PE
REQUIREMENTS COMPLIANCE ТU U 31.3-05758730-056:2007
Operation temperature -50°С ... +50°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 25 years
MAIN OPERATIONAL CHARACTERISTICS
We reserve the right to change this specification without notice
INSULATED WIRES FOR AERIAL LINES
АВКАПс with cross-linked black polyethylene sheath
INSULATED AND PROTECTED SELF-SUPPORTING WIRES
СИП-1 (SIP-1), СИП-2 (SIP-2) with black cross-linked PE insulation
Wire size
СИП-1 1 х 16 + 1 х 25 – 0,6/1СИП-1 3 х 16 + 1 х 25 – 0,6/1СИП-1 3 х 25 + 1 х 35 – 0,6/1СИП-1 3 х 35 + 1 х 50 – 0,6/1СИП-1 3 х 50 + 1 х 50 – 0,6/1СИП-1 3 х 50 + 1 х 70 – 0,6/1СИП-1 3 х 70 + 1 х 70 – 0,6/1СИП-1 3 х 70 + 1 х 95 – 0,6/1СИП-1 3 х 95 + 1 х 70 – 0,6/1СИП-1 3 х 95 + 1 х 95 – 0,6/1СИП-1 3 х 120 + 1 х 95 – 0,6/1СИП-1 3 х 150 + 1 х 95 – 0,6/1СИП-1 3 х 185 + 1 х 95 – 0,6/1СИП-1 3 х 240 + 1 х 95 – 0,6/1СИП-2 1 х 16 + 1 х 25 – 0,6/1СИП-2 3 х 10 + 1 х 16 – 0,6/1СИП-2 3 х 16 + 1 х 25 – 0,6/1СИП-2 3 х 16 + 1 х 54,6 – 0,6/1СИП-2 3 х 25 + 1 х 35 – 0,6/1СИП-2 3 х 25 + 1 х 54,6 – 0,6/1СИП-2 3 х 25 + 1 х 54,6 + 1 х 16 – 0,6/1СИП-2 3 х 25 + 1 х 54,6 + 2 х 16 – 0,6/1СИП-2 3 х 25 + 1 х 54,6 + 1 х 25 – 0,6/1
Rated outer dimensions of the wire, mm (reference)
14,917,95520,98022,50925,98625,98632,10432,10435,20035,20038,04741,59349,17752,971
14,915,16417,95517,95520,98020,98023,50525,11623,505
Weight of the wire, kg/km (reference)
136,26271,87387,38500,05625,23690,23989,50
1045,151164,001232,261417,251682,752277,882642,20165,89209,62301,50404,35419,54495,19562,99630,80593,27
APPLICATION The wire is designed for backbone overhead power lines and their linear branches.For nominal voltage 0,6/1 kV, frequency 50 Hz.
DESIGN 1. Conductor: compacted aluminium multiwire with cross-section 16.0 ... 240.0 mm2 2. Conductor insulation: black cross-linked polyethylene3. Neutral supporting conductor: compacted aluminium alloy multiwire with cross-section 25.0 ... 95.0 mm2
uninsulated for SIP-1 insulated for SIP-2
OPTIONSIt is possible to manufacture СИПг (SIPg) wires with water-blocking compounds, СИПн (SIPn) wires with flame-retardant compounds, and СИПгн (SIPgn) with water-blocking and flame-retardant compounds.
REQUIREMENTS COMPLIANCEТU U 31.3-05758730-048:2007
Operation temperature -60°С ... +50°С
Minimum installation temperature -20°С
Admissible continuous conductor heating temperature +90°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 40 years
MAIN OPERATIONAL CHARACTERISTICS
INSULATED AND PROTECTED SELF-SUPPORTING WIRES
СИП-1, СИП-2 with black cross-linked PE insulation
Wire size
СИП-2 3 х 35 + 1 х 35 – 0,6/1СИП-2 3 х 35 + 1 х 50 – 0,6/1СИП-2 3 х 35 + 1 х 50 + 1 х 16 – 0,6/1СИП-2 3 х 35 + 1 х 50 + 1 х 25 – 0,6/1СИП-2 3 х 35 + 1 х 54,6 – 0,6/1СИП-2 3 х 35 + 1 х 54,6 + 1 х 16 – 0,6/1СИП-2 3 х 35 + 1 х 54,6 + 2 х 16 – 0,6/1СИП-2 3 х 35 + 1 х 54,6 + 1 х 25 – 0,6/СИП-2 3 х 35 + 1 х 54,6 + 2 х 25 – 0,6/СИП-2 3 х 50 + 1 х 50 – 0,6/1СИП-2 3 х 50 + 1 х 50 + 1 х 16 – 0,6/1СИП-2 3 х 50 + 1 х 50 + 1 х 25 – 0,6/1СИП-2 3 х 50 + 1 х 54,6 – 0,6/1СИП-2 3 х 50 + 1 х 54,6 + 1 х 16 – 0,6/1СИП-2 3 х 50 + 1 х 54,6 + 2 х 16 – 0,6/1СИП-2 3 х 50 + 1 х 54,6 + 1 х 25 – 0,6/1СИП-2 3 х 50 + 1 х 54,6 + 2 х 25 – 0,6/1СИП-2 3 х 50 + 1 х 70 – 0,6/1СИП-2 3 х 50 + 1 х 70 + 1 х 16 – 0,6/1СИП-2 3 х 50 + 1 х 70 + 1 х 25 – 0,6/1СИП-2 3 х 70 + 1 х 50 – 0,6/1СИП-2 3 х 70 + 1 х 50 + 1 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 54,6 – 0,6/1СИП-2 3 х 70 + 1 х 54,6 + 1 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 54,6 + 2 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 54,6 + 1 х 25 – 0,6/1СИП-2 3 х 70 + 1 х 54,6 + 2 х 25 – 0,6/1СИП-2 3 х 70 + 1 х 70 – 0,6/1СИП-2 3 х 70 + 1 х 70 + 1 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 70 + 2 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 70 + 1 х 25 – 0,6/1СИП-2 3 х 70 + 1 х 70 + 2 х 25 – 0,6/1СИП-2 3 х 70 + 1 х 95 – 0,6/1СИП-2 3 х 70 + 1 х 95 + 1 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 95 + 2 х 16 – 0,6/1СИП-2 3 х 70 + 1 х 95 + 1 х 35 – 0,6/1СИП-2 3 х 95 + 1 х 70 – 0,6/1СИП-2 3 х 95 + 1 х 70 + 1 х 16 – 0,6/1СИП-2 3 х 95 + 1 х 70 + 2 х 16 – 0,6/1СИП-2 3 х 95 + 1 х 70 + 1 х 25 – 0,6/1СИП-2 3 х 95 + 1 х 70 + 2 х 25 – 0,6/1СИП-2 3 х 95 + 1 х 95 – 0,6/1СИП-2 3 х 95 + 1 х 95 + 1 х 16 – 0,6/1СИП-2 3 х 95 + 1 х 95 + 2 х 16 – 0,6/1СИП-2 3 х 95 + 1 х 95 + 1 х 25 – 0,6/1СИП-2 3 х 120 + 1 х 70 – 0,6/1СИП-2 3 х 120 + 1 х 70 + 1 х 16 – 0,6/1 СИП-2 3 х 120 + 1 х 70 + 2 х 16 – 0,6/1СИП-2 3 х 120 + 1 х 95 – 0,6/1СИП-2 3 х 120 + 1 х 95 + 1 х 16 – 0,6/1СИП-2 3 х 120 + 1 х 95 + 2 х 16 – 0,6/1СИП-2 3 х 120 + 1 х 95 + 1 х 25 – 0,6/1СИП-2 3 х 120 + 1 х 95 + 2 х 25 – 0,6/1СИП-2 3 х 150 + 1 х 70 – 0,6/1СИП-2 3 х 150 + 1 х 95 – 0,6/1СИП-2 3 х 150 + 1 х 95 + 1 х 16 – 0,6/1СИП-2 3 х 150 + 1 х 95 + 2 х 16 – 0,6/1СИП-2 3 х 150 + 1 х 95 + 1 х 25 – 0,6/1СИП-2 3 х 150 + 1 х 95 + 2 х 25 – 0,6/1СИП-2 3 х 185 + 1 х 95 – 0,6/1СИП-2 3 х 240 + 1 х 95 – 0,6/1
Rated outer dimensions of the wire, mm (reference)
22,50922,50925,21825,21822,50925,21828,02025,21828,02025,98629,11329,11325,98629,11332,34829,11332,34825,98629,11329,11332,10435,96734,33935,93739,96335,96739,96335,96732,10439,96335,96739,96332,10435,96739,96335,967
35,239,43643,81839,43643,818
35,239,43643,81839,43638,04742,62547,36138,04742,62547,36142,62547,36141,59341,59346,59751,77546,59751,77549,17752,971
Weight of the wire, kg/km (reference)
501,18562,95610,71640,99576,82644,62712,43674,90772,98668,09735,89766,17702,00769,81837,61808,05898,17754,23831,44861,72954,75
1022,551015,171056,171124,271086,741184,831118,101050,301185,911148,381246,471129,571194,771262,571252,261237,411305,221373,021335,501433,581299,791380,061449,691412,161422,401490,201558,011484,771566,871634,671597,151695,231687,901750,271832,371900,171862,641960,732345,402709,72
We reserve the right to change this specification without notice
INSULATED AND PROTECTED SELF-SUPPORTING WIRES
СИП-3 (SIP-3) with black cross-linked PE insulation
APPLICATION The wire is designed for backbone overhead power lines with 20 kV nominal voltage (for networks with 10, 15, and 20 kV voltage) and 35 kV nominal voltage (for networks with 35 kV voltage), rated frequency 50 Hz.
DESIGN 1. Conductor: compacted aluminium multiwire with cross-section 35.0 ... 240.0 mm2
2. Conductor insulation: black cross-linked PE
OPTIONS It is possible to manufacture СИПг (SIPg) wires with water-blocking compounds, СИПн (SIPn)wires with flame-retardant compounds, and СИПгн (SIPgn) with water-blocking and flame-retardant compounds.
REQUIREMENTS COMPLIANCE ТU U 31.3-05758730-048:2007
Operation temperature -60°С ... +50°С
Minimum installation temperature -20°С
Admissible continuous conductor heating temperature +90°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 40 years
MAIN OPERATIONAL CHARACTERISTICS
Wire size Rated outer dimensions of the wire, mm
(reference)Weight of the wire, kg/км
( reference)СИП-3 1 х 35 – 20СИП-3 1 х 50 – 20СИП-3 1 х 70 – 20СИП-3 1 х 95 – 20СИП-3 1 х 120 – 20СИП-3 1 х 150 – 20СИП-3 1 х 185 – 20СИП-3 1 х 240 – 20СИП-3 1 х 35 – 35СИП-3 1 х 50 – 35СИП-3 1 х 70 – 35СИП-3 1 х 95 – 35СИП-3 1 х 120 – 35СИП-3 1 х 150 – 35СИП-3 1 х 185 – 35СИП-3 1 х 240 – 35
11,34013,60614,52116,83816,98718,45821,20622,77913,74014,78316,92118,20619,38720,85823,60625,179
156,14217,23286,44378,30414,16504,77694,49817,03202,22244,22344,20413,24480,99577,00776,81905,14
We reserve the right to change this specification without notice
СИП-4 with black cross-linked PE insulation
INSULATED AND PROTECTED SELF-SUPPORTING WIRES
APPLICATION The wire is designed for submains of backbone overhead power lines and for on-wall installations. For nominal voltage 0.6/1 kV, frequency 50 Hz.
DESIGN 1. Conductor: compacted aluminium multiwire with cross-section 16.0 ... 240.0 mm2
2. Conductor insulation: black cross-linked PE
OPTIONSIt is possible to manufacture СИПг (SIPg) wires with water-blocking compounds, СИПн (SIPn) wires with flame-retardant compounds, and СИПгн (SIPgn) with water-blocking and flame-retardant compounds.
REQUIREMENTS COMPLIANCEТU U 31.3-05758730-048:2007
Operation temperature - 60°С ... +50°С
Minimum installation temperature -20°С
Admissible continuous conductor heating temperature +90°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 40 years
MAIN OPERATIONAL CHARACTERISTICS
Wire size
СИП-4 1 х 16 – 0,6/1СИП-4 2 х 16 – 0,6/1СИП-4 3 х 16 – 0,6/1СИП-4 4 х 16 – 0,6/1СИП-4 4 х 16 + 1 х 16 – 0,6/1СИП-4 1 х 25 – 0,6/1СИП-4 2 х 25 – 0,6/1СИП-4 2 х 25 + 1 х 16 – 0,6/1СИП-4 2 х 25 + 2 х 16 – 0,6/1СИП-4 3 х 25 – 0,6/1СИП-4 3 х 25 + 1 х 16 – 0,6/1СИП-4 4 х 25 – 0,6/1СИП-4 4 х 25 + 1 х 16 – 0,6/1СИП-4 4 х 25 + 1 х 25 – 0,6/1СИП-4 1 х 35 – 0,6/1СИП-4 2 х 35 – 0,6/1СИП-4 2 х 35 + 1 х 16 – 0,6/1СИП-4 2 х 35 + 2 х 16 – 0,6/1СИП-4 2 х 35 + 1 х 25 – 0,6/1СИП-4 2 х 35 + 2 х 25 – 0,6/1СИП-4 3 х 35 – 0,6/1СИП-4 3 х 35 + 1 х 16 – 0,6/1
Rated outer dimensions of the wire, mm ( reference)
7,45014,9
16,01817,96520,1158,705
17,41118,71720,98018,71720,98020,98023,50523,5059,340
18,68020,08122,50920,08122,50920,08122,509
Weight of the wire, kg/km ( reference)
67,33135,61203,41271,22339,0297,40
196,17263,97331,78294,25362,05392,33460,14490,42124,42250,59318,39386,20353,64446,75375,88443,69
INSULATED AND PROTECTED SELF-SUPPORTING WIRES
СИП-4 (SIP-4)with black cross-linked PE insulation
Wire size
СИП-4 3 х 35 + 1 х 50 – 0,6/1СИП-4 4 х 35 – 0,6/1СИП-4 4 х 35 + 1 х 16 – 0,6/1СИП-4 4 х 35 + 1 х 25 – 0,6/1СИП-4 4 х 35 + 2 х 25 – 0,6/1СИП-4 4 х 35 + 1 х 35 – 0,6/1СИП-4 1 х 50 – 0,6/1СИП-4 2 х 50 – 0,6/1СИП-4 2 х 50 + 1 х 16 – 0,6/1СИП-4 2 х 50 + 2 х 16 – 0,6/1СИП-4 2 х 50 + 1 х 25 – 0,6/1СИП-4 2 х 50 + 2 х 25 – 0,6/1СИП-4 3 х 50 – 0,6/1СИП-4 3 х 50 + 1 х 16 – 0,6/1СИП-4 3 х 50 + 2 х 16 – 0,6/1СИП-4 3 х 50 + 1 х 25 – 0,6/1СИП-4 3 х 50 + 2 х 25 – 0,6/1СИП-4 4 х 50 – 0,6/1СИП-4 4 х 50 + 1 х 16 – 0,6/1СИП-4 4 х 50 + 2 х 16 – 0,6/1СИП-4 4 х 50 + 1 х 25 – 0,6/1СИП-4 4 х 50 + 2 х 25 – 0,6/1СИП-4 4 х 50 + 1 х 35 – 0,6/1СИП-4 4 х 50 + 1 х 50 – 0,6/1СИП-4 2 х 70 – 0,6/1СИП-4 3 х 70 – 0,6/1СИП-4 4 х 70 – 0,6/1СИП-4 4 х 70 + 1 х 25 – 0,6/1СИП-4 4 х 70 + 1 х 35 – 0,6/1СИП-4 4 х 70 + 1 х 70 – 0,6/1СИП-4 2 х 95 – 0,6/1СИП-4 3 х 95 – 0,6/1СИП-4 4 х 95 – 0,6/1СИП-4 4 х 95 + 1 х 25 – 0,6/1СИП-4 4 х 95 + 1 х 35 – 0,6/1СИП-4 2 х 120 – 0,6/1СИП-4 3 х 120 – 0,6/1СИП-4 4 х 120 – 0,6/1СИП-4 4 х 120 + 1 х 35 – 0,6/1СИП-4 4 х 120 + 2 х 35 – 0,6/1СИП-4 2 х 150 – 0,6/1СИП-4 2 х 185 – 0,6/1СИП-4 2 х 240 – 0,6/1СИП-4 4 х 150 – 0,6/1СИП-4 4 х 185 – 0,6/1СИП-4 4 х 240 – 0,6/1
Rated outer dimensions of the wire, mm (reference)
22,50922,50925,21825,21828,02025,21810,78321,56523,18325,98623,18325,98623,18325,98629,11325,98629,11325,98629,11332,34829,11332,34829,11329,11326,64228,64032,10435,96735,96735,96729,21231,403
35,239,43639,43631,57433,94238,04742,62547,36134,51740,81143,95941,59349,17752,971
Weight of the wire kg/km (reference)
539,77501,18568,98599,26697,34626,47165,86334,04401,85469,65432,13530,21501,06568,87636,67599,15697,23668,09735,89803,70766,17864,25793,38835,11525,15787,72
1050,301148,381175,591312,87649,89974,84
1299,791397,871425,08773,22
1159,821546,431671,731797,02950,21
1346,971589,851900,432693,933179,69
We reserve the right to change this specification without notice
INSULATED SELF-SUPPORTING WIRE FOR 0.38 LINES
CAПт with black thermoplastic polyethylene insulation
APPLICATION The wire is designed for electricity transmission and distribution in overhead power transmission lines, outdoor installation in main feeds and submains up to lead-ins to household buildings. For areas with moderate climate. For nominal voltage 0.6 or 1 kV, frequency 50 Hz.
DESIGN - Conductor: round aluminium wire (single or multiple). - Insulation: black thermoplastic polyethylene
REQUIREMENTS COMPLIANCEТU U 31.3-05758730-048:2007
Operation temperature -50°С ... +50°С
Minimum installation temperature -20°С
Admissible continuous temperature of conductors +90°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 40 years
MAIN OPERATIONAL CHARACTERISTICS
Number and cross-section of main conductors
Rated outer dimensions of the wire, mm (reference)
Wire weight, kg/km (reference)
2 х 102 х 162 х 254 х 104 х 164 х 254 х 354 х 504 х 704 х 95
4 х 120
12,58414,5
17,81115,16417,47321,46223,95526,46832,58635,68239,493
94,05130,49200,73188,09260,99401,46534,60679,04
1063,381314,071601,15
We reserve the right to change this specification without notice
WIRES FOR ELECTRIC INSTALLATIONS
ВВ (VV) round single wire with PVC insulation and PVC sheath
APPLICATIONThe wire is designed for electric installations with the nominal voltage up to 380/660 V or DC voltage up to 1,000 V inclusive. It is also used for electric circuit assembly inside of devices, for lighting fittings in dry and damp premises, and for externally installed circuits. Application of wires by their flexibility:ВВ-1 (VV-1) - for fixed installation ВВ-2 (VV-2) - for areas with possible bendsВВ-4 (VV-4) - for areas with frequent bends
DESIGN- conductor: single copper wire (ВВ-1) or multiwire (ВВ-2; ВВ-4) with cross-section 1.0 ... 35.0 mm2
- conductor insulation: PVC- sheath: PVC
REQUIREMENTS COMPLIANCEТU U 05758730.011-99
Operation temperature - 50°С ... +70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
Wire type
ВВ-1 (VV-1)
ВВ-2 (VV-2)
ВВ-4 (VV-4)
Maximum outer diameter of the wire, mm (reference)
3,934,384,98
4,55,21
Nominal conductorcross-section, mm2
1,01,52,51,01,52,54,06,0
10,016,025,035,01,01,52,5
Weight of the wire, kg/km (reference)
24,5832,3445,89
32,8748,63
We reserve the right to change this specification without notice
Wire type
ВВП-1 (VVP-1)
ВВП-2 (VVP-2)
Maximum outer diameter of the wire, mm (reference)
4,1х6,54,6х7,45,4х8,8
---
4,1х8,84,6х10,15,4х12,1
---
4,3х6,74,7х7,75,6х9,2
6,2х10,36,9х11,68,5х14,59,7х16,84,3х9,2
4,8х10,75,6х12,8
Number and nominal cross-section of conductor, mm2
2 х 1,02 х 1,52 х 2,52 х 42 х 6
2 х 103 х 1
3 х 1,53 х 2,53 х 43 х 6
3 х 102 х 1
2 х 1,52 х 2,52 х 42 х 6
2 х 102 х 163 х 1
3 х 1,53 х 2,5
Wire weight, kg/km (reference)
44,6960,1990,34
127,28175,26279,3164,6791,03
132,66183,11259,30415,1744,4561,2696,07
133,46182,83293,67424,5964,3189,56
141,32
WIRES FOR ELECTRIC INSTALLATION
ВВП flat wire with PVC insulation and PVC sheath
APPLICATION The wire is designed for electric installations with the nominal voltage up to 380/660 V or DC voltage up to 1,000 V inclusive. It is also used for electric circuit assembly inside walls, on boards, in cavitated passages of building units or for embedding in plaster in dry or damp premises; for wiring of power networks and lighting leads. Application of wires by their flexibility:ВВП-1 (VVP-1) - for fixed installation ВВП-2 (VVP-2) - for areas with possible bendsВВП-4 (VVP-4) - for areas with frequent bends
DESIGN- conductor: single copper wire (ВВП-1) or multiwire (ВВП-2; ВВП-4) with cross-section 1. 0 ... 16.0 mm2
- conductor insulation: PVC. Insulated conductors are laid parallel within one plane.- sheath: PVC
REQUIREMENTS COMPLIANCEТU U 05758730.011-99
Operation temperature -50°С ...+70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 10 minimum outer wire sizes
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
WIRES FOR ELECTRIC INSTALLATIONS
ВВПflat wire with PVC insulation and PVC sheath
Wire type
ВВП-2 (VVP-2)
ВВП-4 (VVP-4)
Maximum outer diameter of the wire, mm (reference)
6,4х14,76,9х16,48,5х20,69,7х23,95,6х16,46,4х18,86,9х21,14,9х7,95,7х9,0
6,7х10,7--
Number and nominal cross-section of conductor, mm2
3 х 43 х 6
3 х 103 х 164 х 2,54 х 44 х 62 х 1
2 х 1,52 х 2,53 х 1,53 х 2,5
Wire weight, kg/km (reference)
202,10271,16437,41633,75186,56267,26359,48
-65,60
-96,11
144,65
We reserve the right to change this specification without notice
Wire Type
ВВПз-1 (VVPz-1)
ВВПз-2 (VVPz-2)
ВВПз-4 (VVPz-4)
Maximum outer diameter of the wire, mm (reference)
4,1х7,64,6х8,5
5,4х10,14,1х9,2
4,6х11,35,4х13,34,3х7,94,8х8,95,6х9,2
6,2х11,76,9х13,48,5х17,0
-9,7х19,24,3х10,34,8х11,85,6х14,06,9х18,18,0х20,08,5х23,19,7х27,04,3х8,04,9х9,1
5,7х10,8
Number and nominal cross-sectionof conductor,mm2
2 х 1 + 1 х 12 х 1,5 + 1 х 1
2 х 2,5 х 1 + 1,53 х 1 + 1 х 1
3 х 1,5 + 1 х 13 х 2,5 + 1 х 12 х 1 + 1 х 1
2 х 1,5 + 1 х 12 х 2,5 + 1 х 1,52 х 4,0 + 1 х 1,52 х 6 + 1 х 2,52 х 10 + 1 х 42 х 10 + 1 х 62 х 16 + 1 х 63 х 1 + 1 х 1
3 х 1,5 + 1 х 13 х 2,5 + 1 х 13 х 4 + 1 х 1,53 х 6 + 1 х 2,53 х 10 + 1 х 43 х 16 + 1 х 62 х 1 + 1 х 1
2 х 1,5 + 1 х 12 х 2,5 + 1 х 1,5
Wire weight, kg/km ( reference)
60,5474,32
111,0581,22
105,70152,7758,0475,56
117,18155,50223,10350,60371,52514,7377,91
103,86162,08231,12
163,348502,88727,69
---
WIRES FOR ELECTRIC INSTALLATION
ВВПз flat wire with ground core, PVC insulation and PVC sheath
APPLICATION The wire is designed for electric installations with the nominal voltage up to 380/660 V or DC voltage up to 1,000 V inclusive. It is also used for electric circuit assembly inside walls, on boards, in cavitated passages of building units or for embedding in plaster in dry or damp premises; for wiring of power networks and lighting leads when grounding is needed. Application of wires by their flexibility:
При ВВПз-1 (VVPz-1) - for fixed installation ВВПз-2 (VVPz-2) - for areas with possible bendsВВПз-4 (VVPz-4) - for areas with frequent bends
DESIGN- conductor: single copper wire (ВВПз-1) or multiwire (ВВПз-2; ВВПз-4) with cross-section 1.0 ... 16.0 mm2
- conductor insulation: PVC- grounding core: copper single or multiple wire. Insulated conductors and grounding core are laid parallel within one plane. - sheath: PVC
REQUIREMENTS COMPLIANCEТU U 05758730.011-99
Operation temperature -50°С ... +70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductor +70°С
Minimum bending radius upon installation 10 minimum outer wire sizes жных размеров провода
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
We reserve the right to change this specification without notice
WIRES FOR ELECTRIC INSTALLATIONS
Nominal conductor cross-section, mm2
2,54,06,0
10,016,025,035,0
Rated outer diameter of the wire, mm (reference)
3,43,94,45,66,58,8
10,0
Rated weight of 1 km of the wire, kg (reference)
15,421,028,146,366,1
114,8146,9
We reserve the right to change this specification without notice
АПВ (APV)with PVC insulation
APPLICATIONThe wire is designed for fixed wiring in lighting and power networks and for assembly of electrical equipment, devices and machines with the nominal voltage up to 450 V (for networks up to 450/750 V) and frequency up to 400 Hz, or DC voltage up to 1,000 V. For installation in steel tubes, cavitated ducts of building units, on trays, ect.; for electric circuit wiring. АПВ (APV) – for fixed installation
DESIGN- conductor: single or multistrained aluminium wire with cross-section 2.5 ... 240 mm2
- conductor insulation: PVCInsulation colours: white, natural or grey - Б (B), yellow or orange - Ж (Zh), red or pink - K (K), dark-blue or blue - C (S), green - З (Z), brown - Кч (Kch), black or violet - Ч (Ch), green-yellow - З-Ж (Z-Zh)
REQUIREMENTS COMPLIANCEТU U 31.3-05758730-025-2002
Operation temperature -50°С ... +70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS ТЕРИС ТИКИ КАБЕЛЯ
WIRES FOR ELECTRIC INSTALLATION
ПВ with PVC insulation
APPLICATION The wire is designed for fixed wiring in lighting and power networks and for assembly of electrical equipment, devices and machines with the nominal voltage up to 450 V (for networks up to 450/750 V) and frequency up to 400 Hz, or DC voltage up to 1,000 V. For installation in steel tubes, cavitated ducts of building units, on trays, ect.; for electric circuit wiring. ПВ1 (PV1) – for fixed installationПВ2, ПВ3 (PV2, PV3) - for areas with possible bendsПВ4 (PV4) – for areas with frequent bends
DESIGN - conductor: single or multistranded copper wire with cross-sections: ПВ1 (PV1) – 0.5 ... 240 mm2
ПВ2 (PV2) – 2.5 ... 240 mm2
ПВ3 (PV3) – 0.5 ... 240 mm2
ПВ4 (PV4) – 0.5 ... 240 mm2
- conductor insulation: PVC Insulation colours: white, natural or grey - Б (B), yellow or orange - Ж (Zh), red or pink - K (K), dark-blue or blue - C (S), green - З (Z), brown - Кч (Kch), black or violet - Ч (Ch), green-yellow - З-Ж (Z-Zh)
REQUIREMENTS COMPLIANCEТU U 31.3-05758730-025-2002
Operation temperature -50°С ... +70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation
for ПВ1 (PV1) wires 10 wire diameters
for ПВ2, ПВ3, ПВ4 (PV2, PV3, PV4) wires 5 wire diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
RATED OUTER DIAMETER OF THE WIRE, mm (reference)
ПВ1 (PV1)
22,1702,3302,7803,38
3,8504,36
5,5707,1
8,8209,197
10,64812,34614,40615,84218,03020,02522,762
ПВ3 (PV3)
2,12,310
2,42,93,64,14,86
8,2259,9
11,413,45315,69217,96019,582
23,224,584
31,2
ПВ4 (PV4)
2,140
2,5403,0683,7194,8375,3356,980
810,097
1213,6
-20,728
----
Nominal conductor cross-section, mm2
0,50,75
11,52,546
10162535507095
120150185240
WIRES FOR ELECTRIC INSTALLATIONS
ПВ (PV)with PVC insulation
RATED WEIGHT OF 1 KM OF THE WIRE, KG (reference)
ПВ1 (PV1)
810,5413,2919,4330,8145,6265,18
108,23174,50274,04355,31474,47683,71939,17
1174,151472,011823,052394,99
ПВ3 (PV3)
8,5811,5112,9219,5231,9546,7271,19
111,24193,70
283394,23545,80762,74
1042,271281,241629,302001,772640,17
ПВ4 (PV4)
8,76-
14,4521,0833,3752,8374,62
130,42186,26305,72410,05565,62
-1063,63
----
Nominal conductor cross-section, mm2
0,50,75
11,52,546
10162535507095
120150185240
We reserve the right to change this specification without notice
WIRES FOR ELECTRIC INSTALLATION
АППВ with PVC insulation
APPLICATION The wire is designed for fixed wiring in lighting and power networks and for assembly of electrical equipment, devices and machines with the nominal voltage up to 450 V (for networks up to 450/750 V) and frequency up to 400 Hz, or DC voltage up to 1,000 V. For installation in steel tubes, cavitated ducts of building units, on trays, ect.; for electric circuit wiring. For inflexible installation.
DESIGN - conductor: single aluminium wire with cross-section 2.5...6.0 mm2 - number of conductors: 2 or 3. Conductors are laid parallel within one plane and insulated with a separating strip base. - conductor insulation: PVC. Insulation colours: white, natural or grey - Б (B), yellow or orange - Ж (Zh), red or pink - K (K), dark-blue or blue - C (S), green - З (Z), brown - Кч (Kch), black or violet - Ч (Ch), green-yellow - З-Ж (Z-Zh).
REQUIREMENTS COMPLIANCE ТU U 31.3-05758730-025-2002
Operation temperature -50°С . ... +70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
We reserve the right to change this specification without notice
Wire size
АППВ 2х2,5АППВ 2х4,0АППВ 2х6,0АППВ 3х2,5АППВ 3х4,0АППВ 2х6,0
АППВ 3х6,0
Rated outer wire dimensions, mm (reference)
3,4х7,83,9х8,74,4х9,7
3,4х12,13,9х13,64,4х15,1
-
Wire weight, kg/km (reference)
32,243,557,950,066,988,6
80,43
WIRES FOR ELECTRIC INSTALLATIONS
ППВ (PPV)with PVC insulation
Nominal conductor cross-section, mm2
ППВ 2 х 1ППВ 2 х 1,5ППВ 2 х 2,5ППВ 2 х 4ППВ 3 х 1,5ППВ 3 х 2,5ППВ 3 х 4ППВ 3 х 6
Rated outer dimensions of the wire, mm (reference)
-2,8х6,63,4х7,83,9х8,7
2,8х10,33,4х12,13,9х13,6
-
Wire weight, kg/km (reference)
27,2439,5269,2991,9159,6293,77
138,20196,87
We reserve the right to change this specification without notice
APPLICATION The wire is designed for fixed wiring in lighting and power networks and for assembly of electrical equipment, devices and machines with the nominal voltage up to 450 V (for networks up to 450/750 V) and frequency up to 400 Hz, or DC voltage up to 1,000 V. For installation in steel tubes, cavitated ducts of building units, on trays, ect.; for electric circuit wiring. For inflexible installation.
DESIGN - conductor: single copper wire with cross-section 1.0 ... 6.0 mm2
- number of conductors: 2 or 3. The conductors are laid parallel, in one plane, insulated with a separating strip base.- conductor insulation: PVC. Insulation colours: white, natural or grey - Б (B), yellow or orange - Ж (Zh), red or pink - K (K), dark-blue or blue - C (S), green - З (Z), brown - Кч (Kch), black or violet - Ч (Ch), green-yellow - З-Ж (Z-Zh).
REQUIREMENTS COMPLIANCE ТU U 31.3-05758730-025-2002
Operation temperature -50°С ... +70°С
Installation temperature -15°С ... +70°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 10 wire diameters
Minimum service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
WINDING WIRES FOR SUBMERSIBLE ELECTRIC MOTORS
ПВДП with double PE insulation хслойной изоляцией
APPLICATION The wire is designed for winding of stators of submersible water-filled electric motorscontinuously operating in waters of artesian wells (AC voltage up to 660 V,frequency 40-60 Hz).
DESIGN - conductor: single or multistrained copper wire, Ø 0.95 ... 5.3 mm - conductor insulation: 2 layers of polyethylene
OPTIONS Other diameters of conductors are possible.
REQUIREMENTS COMPLIANCE ТU 16-505.733-78
Operation temperature -50°С ... +80°С
Permissible working pressure 7.09 МPа max
MAIN OPERATIONAL CHARACTERISTICS
We reserve the right to change this specification without notice
Conductor diameter, mm, nom.
0,951,061,181,41,61,82,02,362,83,03,183,543,754,55,3
Rated outer diameter, mm (reference)
1,751,861,982,32,52,83,0
3,564,04,2
4,584,94
5,1505,96,8
Wire weight, kg/ km (reference)
7,949,61
11,6316,1920,6526,1031,7044,2560,9069,3665,0179,3388,35
123,61167,65
RATED WEIGHT OF 1 KM OF THE WIRE, kg (reference)Rated outer diameter of the wire, mm, for 600 V voltage with cross-section, mm2
Rated outer diameter of the wire, mm, for 600 V voltage with cross-section, mm2
0,08
--
0,08---
0,12
--
0,12---
0,20
--
0,20---
0,35
--
0,356,835,88
-
0,50
-6,48
0,506,83
-6,5
0,75
-9,6
0,75-
10,52-
1,00
--
1,00---
1,5
-16,79
1,5-
17,87-
2,5
--
2,5---
Conductor gradeacc. to GOST 22483
14
141
Wire type
НВ (NV)
НВ (NV)
НВМ (NVM)
HOOK-UP WIRES
НВМ (NVM), НВ (NV)with PVC insulation
We reserve the right to change this specification without notice
OPTIONS It is possible to manufacture НП (NP) wire with a tinned copper conductor and PE insulation.
Operation temperature -50°С ... +105°С
Average service life 15 years
MAIN OPERATIONAL CHARACTERISTICS
APPLICATION The wire is designed for operation in circuits of general industrial devices with the nominal AC voltage 600 and 1000 V, frequency up to 5,000 Hz and DC voltage 840 and 1,400 V respectively.
DESIGN
- conductor: single or multiple copper wire (НВМ) or tinned copper wire (НВ) with conductor cross-section 0.08; 0.12; 0.20; 0.35; 0.50; 0.75; 1.00; 1.5; 2.5 mm2 - conductor insulation: PVC. Insulation colours: white, natural or grey - Б, yellow or orange - Ж, red or pink - К, dark blue or blue - С, green - З, brown - Кч, black or violet - Ч
REQUIREMENTS COMPLIANCE GOST 17515
RATED OUTER DIAMETER OF THE WIRE, mm (reference) Rated outer diameter of the wire, mm, for 600 V voltage with cross-section, mm2
Rated outer diameter of the wire, mm, for 600 V voltage with cross-section, mm2
0,08
--
0,08---
0,12
--
0,12---
0,20
--
0,20---
0,35
--
0,351,7
1,68-
0,50
-1,6
0,501,7
-1,6
0,75
-1,945
0,75-
2,145-
1,00
--
1,00---
1,5
-2,310
1,5-
2,510-
2,5
--
2,5---
Conductor grade acc. to GOST 22483
1
4
141
Wire type
НВ (NV)
НВ (NV)
НВМ (NVM)
CONNECTING WIRES AND CORDS
ПВСн flexible wire with PVC insulation and PVC sheath
APPLICATION The wire is designed for connection of machines and household appliances to networks with 380 V nominal AC voltage and to systems with 380/660 V.
DESIGN - conductor: copper multiwire with cross-sections 0.75; 1.0; 1.5; 2.5 mm2
- conductor insulation: PVC. Number of conductors: 2; 3; 4 or 5. Insulated conductors are twisted.- sheath: PVC. Sheath colours: white, blue, yellow, green, brown, red, grey, dark blue or black.
REQUIREMENTS COMPLIANCE GOST 7399-97, IEC 227
Operation temperature 25°С ... +40°С
Admissible continuous temperature of conductors +70°С
Conductor grade according to GOST 22483 5
Minimum bending radius upon installation:
ПВС (PVS) up to 1.0 mm2 40 mm
ПВС (PVS) up to 2.5 mm2 60 mm
MAIN OPERATIONAL CHARACTERISTICS
Conductor insulation colours Number of conductors
2345
Wire with a grounding core
- green-yellow, blue, brown
green-yellow, blue, black, brown green-yellow, blue, black, brown,
black or brown
blue, brown blue, black, brown
blue, black, brown, black or brown blue, black, brown, black or brown,
black or brown
Wire without a grounding core
Number and nominal cross-section of conductors, mm2
2 х 0,62 х 0,752 х 12 х 1,52 х 2,52 х 42 х 0,6 + 1 х 0,62 х 0,75 + 1 х 0,752 х 1 + 1 х 12 х 1,5 + 1 х 1,52 х 2,5 + 1 х 2,53 х 0,6 + 1 х 0,63 х 0,75 + 1 х 0,75
Rated outer diameter of the wire, mm (reference)
6,06,4
6,6807,7359,438
10,8206,3306,7607,0618,395
10,1966,9027,384
Wire weight , kg/km (reference)
46,7858,4866,1691,15
140,23195,0359,0169,1479,97
113,85175,1671,1483,39
CONNECTING WIRES AND CORDS
ПВСн (PVSn)flexible wire with PVC insulation and PVC sheath
We reserve the right to change this specification without notice
Number and nominal cross-section of conductors, mm2
3 х 1 + 1 х 13 х 1,5 + 1 х 1,53 х 2,5 + 1 х 2,53 х 4 + 1 х 44 х 0,75 + 1 х 0,754 х 1 + 1 х 14 х 1,5 + 1 х 1,54 х 2,5 + 1 х 2,5
Rated outer diameter of the wire, mm (reference)
7,9219,393
11,16312,546
8,288,658
10,48312,441
Wire weight, kg/ km (reference)
100,92149,20214,04295,52105,56121,52179,19268,75
INSTALLATION WIRES
ПВСм, ПВСмп with PVC insulation and PVC sheath
APPLICATION The wire is designed for installation and stationary connection of electric equipment, household and similar machines to networks with the nominal AC voltage up to 380/660 V.
DESIGN 1. Conductor: copper multiwire with cross-sections 0.75 ... 25.0 mm2
2. Insulation: PVC. Number of conductors: 2; 3; 4 or 5. Insulated conductors are twisted.3. Belt insulation: synthetic tape (belt insulation is only applied in ПВСмп (PVSmp) wires).4. Sheath: PVC. Sheath colours: white, grey or black.
REQUIREMENTS COMPLIANCE ТU U 31.3-05758730-039
Operation temperature -25°С ... +40°С
Installation temperature -15°С ... +40°С
Admissible continuous temperature of conductors +70°С
Conductor grade according to GOST 22483 3
Minimum installation bending radius 6 wire diameters
Minimum service life 6 years
MAIN OPERATIONAL CHARACTERISTICS
Wire size
ПВСм 2 х 0,75ПВСм 2 х 1ПВСм 2 х 1,5ПВСм 2 х 2,5ПВСм 2 х 4ПВСм 2 х 6ПВСм 2 х 10ПВСм 2 х 16ПВСм 2 х 0,75 + 1 х 0,75ПВСм 2 х 1 + 1 х 1ПВСм 2 х 1,5 + 1 х 1,5ПВСм 2 х 2,5 + 1 х 2,5ПВСм 2 х 4 + 1 х 4ПВСм 2 х 6 + 1 х 6ПВСм 2 х 10 + 1 х 10ПВСм 2 х 16 + 1 х 16ПВСм 3 х 0,75 + 1 х 0,75ПВСм 3 х 1 + 1 х 1ПВСм 3 х 1,5 + 1 х 1,5ПВСм 3 х 2,5 + 1 х 2,5ПВСм 3 х 4 + 1 х 4ПВСм 3 х 6 + 1 х 6
Rated outer diameter of the wire, mm (reference)
6,2206,47,49,2
10,612,615,0
19,8506,5566,76
8,0359,940
11,21513,320
15,921,0847,1677,5848,989
10,87612,28114,568
Weight of the wire, kg/km ( reference)
55,5860,8684,37
134,18187,93276,08404,63695,2866,8572,70
105,69167,87231,35345,12510,94863,7580,7791,62
132,81205,17284,91426,49
Wire size
ПВСм 3 х 10 + 1 х 10ПВСм 3 х 16 + 1 х 16ПВСм 4 х1 + 1 х 1ПВСм 4 х 1,5 + 1 х 1,5ПВСм 4 х 2,5 + 1 х 2,5ПВСм 4 х 4 + 1 х 4ПВСм 4 х 6 + 1 х 6ПВСм 4 х 10 + 1 х 10ПВСм 4 х 16 + 1 х 16
Rated outer diameter of the wire, mm (reference)
17,46023,222
8,2810,03012,12013,07015,960
19,626,008
Weight of the wire, kg/km (reference)
635,361070,67111,69166,62256,88337,41523,68804,39
1379,29
INSTALLATION WIRES
ПВСм (PVSm), ПВСмп (PVSmp)with PVC insulation and PVC sheath
Wire size
ПВСмп 2 х 0,75ПВСмп 2 х 1ПВСмп 2 х 1,5ПВСмп 2 х 2,5ПВСмп 2 х 4ПВСмп 2 х 6ПВСмп 2 х 10ПВСмп 2 х 16ПВСмп 2 х 0,75 + 1 х 0,75ПВСмп 2 х 1 + 1 х 1ПВСмп 2 х 1,5 + 1 х 1,5ПВСмп 2 х 2,5 + 1 х 2,5ПВСмп 2 х 4 +1 х 4ПВСмп 3х6,0ПВСмп 2 х 10 + 1 х 10ПВСмп 2 х 16 + 1 х 16ПВСмп 3 х 0,75 + 1 х 0,75ПВСмп 3 х 1 + 1 х 1ПВСмп 3 х 1,5 + 1 х 1,5ПВСмп 3 х 2,5 + 1 х 2,5ПВСмп 3 х 4 + 1 х 4 ПВСмп 3 х 6 + 1 х 6ПВСмп 3 х 10 + 1 х 10ПВСмп 3 х 16 + 1 х 16ПВСмп 3 х 25 + 1 х 25ПВСмп 4 х 1 + 1 х 1ПВСмп 4 х 1,5 + 1 х 1,5ПВСмп 4 х 2,5 + 1 х 2,5ПВСмп 4 х 4 + 1 х 4ПВСмп 4 х 6 + 1 х 6ПВСмп 4 х 10 + 1 х 10ПВСмп 4 х 16 + 1 х 16ПВСмп 4 х 25+ 1 х 25
Rated outer diameter of the wire, mm (reference)
6,266,4407,4409,440
10,64012,64015,04019,9206,606
6,88,0759,980
11,25513,36015,94021,2547,2077,6249,029
10,91612,32114,638
17,523,29225,054
8,3210,07012,16013,510
16,019,64026,07827,603
Wire weight, kg/km (reference)
44,0547,6366,38
108,29148,65223,69323,02543,6157,2462,1790,41
144,07200,36306,26444,23753,6171,3981,40
177,77181,86254,56385,68569,98970,73
1326,55100,72150,85232,47318,56479,88714,50
1248,941669,66
We reserve the right to change this specification without notice
CONNECTIVE WIRES AND CORDS
ШВПн flexible cord with PVC insulation
APPLICATION The cord is designed for connection of machines, household appliances and similar devicesto networks with 380 V nominal AC voltage and to systems with 380/660 V.It is used for connection of electronics, household lighting units, microclimate electrical appliances, electromechanical household appliances, electric fans and other similar devices.Rare, light mechanical deformation is permissible.
DESIGN 1. Conductor: multiple copper wire with cross-sections 0.35 ... 2.5 mm2
2. Conductor insulation: PVC. Number of conductors: 2. Insulated conductors are laid parallel, with separation. Insulation colours: white, blue, yellow, green, brown, red, ivory, grey, dark blue or black.
REQUIREMENTS COMPLIANCEGOST 7399-97, IEC 227
Operation temperature -25°С ... +40°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 30 mm
MAIN OPERATIONAL CHARACTERISTICS
Number and nominal cross-section of conductors, mm2
2х0,502х0,752х1,502х2,50
Rated outer dimensions of the cord, mm ( reference)
2,5х5,12,8х5,63,3х6,53,7х7,4
Weight of the cord, kg/km (reference)
20,7626,7843,4564,66
We reserve the right to change this specification without notice these types of the cord are manufactured under individual orders
CONNECTIVE WIRES AND CORDS
ШВВПн with PVC insulation, PVC sheath, flexible
Number and nominal cross-section of connductors, mm2
Rated outer dimensions of the cord, mm (reference)
3,1х5,13,4х5,63,1х7,03,4х7,8
-4,1х6,94,7х8,2
--
4,1х9,84,7х11,6
-
Weight of the cord, kg/km (reference)
25,1331,9337,3147,9037,7152,4878,87
152,5159,4882,36
124,36238,00
these types of the cord are manufactured under individual orders We reserve the right to change this specification without notice
Operation temperature -25°С ... +40°С
Admissible continuous temperature of conductors +70°С
Minimum bending radius upon installation 30 mm
MAIN OPERATIONAL CHARACTERISTICS
APPLICATION The cord is designed for connection of machines, household appliances and similar devices to networks with 380 V nominal AC voltage and to systems with 380/660 V. It is also used for connection of microclimate and personal hygiene electrical appliances, electric soldering irons, lamps, kitchen electromecanical appliances, electronics, extension cords, washing machines, refrigerators and other similar devices used in administrative and living premises.
DESIGN 1. Conductor: miltiple copper wire with cross-sections 0.5 ... 4.0 mm2
2. Conductor insulation: PVC. Number of conductors: 2 or 3. Insulated conductors are laid parallel.3. Sheath: PVC Sheath colours: white, blue, yellow, green, brown, red, grey, dark blue or black.
REQUIREMENTS COMPLIANCE GOST 7399-97, IEC 227
Conductor insulation colours Number of conductors
23
Cord with a grounding core
- yellow-green, blue, brown
blue, brown blue, black, brown
Cord without a grounding core
2 х 0,52 х 0,753 х 0,53 х 0,752 х 12 х 1,52 х 2,52 х 43 х 13 х 1,53 х 2,53 х 4
E:\pcc\pcc_0_Combine.pdf
76
top related