continuous hinge, clamped cover · pdf filenema 250-1997. type 2 enclosures constructed for...
Post on 26-Mar-2018
214 Views
Preview:
TRANSCRIPT
^ HAMMONDmm
www.hammfg.com
1418 304 Stainless Steel Single Door Enclosures - NEMA 4XContinuous Hinge, Clamped Cover
0.4'nw
3
_^__^
* Y
t
---.
1 -
""""Kn,_r°_r_
iL1
r
ej
iL1
*j1
1 nEH3.25
X-«-~|J
z
t
•-2.00
v
2.00 — "| r
n*] i ~ ~i
i ioii iLJ i i-1 *
"'Hi::*-> 1 1
LI l_l
©
a\
il * l\ :— \ Lr\<a ^
'C
^
ii
L•-
r—|_
i
^f
lh-
r
&
~~
fi\
1
„^
F
- 1i
]-
€)_/s
-O-(L
1
i
0.88 :
I
0.88
2.00
.
1
IT
/- BONDING/ STUD
= $>- GROUND/STUD
3 t^_j o n«
n
)
— - r£=«t
«S
50
1
n.
i
f_T.
I
J
fM
TYP
J_
When A=
3036424860
M=
7.009.009.88
11.3814.38
Front View Side View
-"• [-•-0.94
4
•* —
s PIANOHINGE
M2.38
A
^CENTER OF DOOR
_N»j~i — rHyritr
GASKET
.375-16COLLAR STUD
\ 12 GAV TPANEL\£b t ft
*0.88|
1 1.20
t
0.75
^L\ t BODY STIFFENER -J /MOUNTING FEEf
0 19 Section Y-Y
0.63
Section Z-Z
O Vertical stiffener required on KK, LL & M only.© Omit center body stiffener if A is less than 41".© Padlocking hasp and staple.O Omit 2 middle studs if A is less than 31".© Omit body stiffeners if A or B is less than 29".© Omit 2 middle studs if B is less than 31".O Omit door stiffener if A or B is less than 31"
except if AxB is 42"x30".
Literature pocket supplied loose.Number of door clamps varies to enclosure size.
Panel Size Mtg.CentersPart No.
1418N4SSB62
1418N4SSG62
1418N4SSCR62
1418N4SSC62
1418N4SSD62
1418N4SSE61418N4SSB8
1418N4SSC82
1418N4SSD82
1418N4SSER81418N4SSH8
1418N4SSE81418N4SSJ8
1418N4SSKR81418N4SSF8
1418N4SSK81418N4SSKK8
1418N4SSL8
A
16
1616
'2020241620202024
24242430303036
B
12
1620162020121620241620243020243024
C
6
66666888
88
8888888
D
13
13131717
21131717
1721212121272727
33
E
913171317179
1317
2113172127172127
21
F
9.5
10,014.0
10.014.014.09.5
10.014.0
18.010.014.018.024.014.018.024.018.0
ShipG Wt. Ibs.
17.2517.2517.2521.2521.2525.2517.2521.2521.2521.2525.25
25.2525.25
25.2531.2531.2531.2537.25
283038384061323852
61616175
897289
100100
Panel SizePart No.
1418N4SSM81418N4SSP81
1418N4SSS81
1418N4SSC101418N4SSE10
1418N4SSL101418N4SSM10
1418N4SSO101
1418N4SSJ12
1418N4SSK121418N4SSM12
1418N4SSLL121
1418N4SSS121
1418N4SST121
1418N4SSK16
1418N4SSM161418N4SSS161
A
364248
2024
36364224
3036364860303648
B
303636162024303024
2430
3636
36243036
C
888
1010101010121212
1212
1216
1616
D
3339451721
33333921273333455727
3345
E
27
33331317212727212127
333333212733
Mtg.Centers ShipF
24
30301014
182424181824
303030182430
1 Meets UL standards
G
37.25
43.2549.25
21.2525.25
37.2537.25
43.2525.25
31.2537.25
37.2549.25
61.2531.2537.2549.252 Flat
Wt. Ibs.
1211772074766
108125
17S7195
136202225270100149290
panel
Meets UL standards : Flat panel
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
© Hammond Manufacturing
Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice
W1
*• HAMMONDWT E N C L O S U R E S
www.hammfg.com
s£>13i|s§51*&8S 8'Isr- 3
fd
I
1418 304 Stainless Steel Single Door Enclosures - NEMA 4XContinuous Hinge, Clamped Cover
Application• Designed for use as instrument
enclosures, electric, hydraulic orpneumatic control housings,electrical junction boxes or terminalwiring enclosures.
• Provides protection whereequipment may be hosed down orotherwise be very wet, or in specificapplications where corrosion is aserious problem.
Standards• UL 508 Type 3R, 4, 4X, and 12• CSA Type 3R, 4, 4X, and 12• Complies with
« NEMAType3R, 4, 4X, 12 and 13« JIC EGP-1-1967 unless marked1
« I EC 529, IP66
Construction• Formed 14 gauge Type 304
stainless steel bodies and doors.• Smooth, continuously welded seams
without knockouts, cutouts or holes.» Door and body stiffeners are
provided in the larger enclosures forextra rigidity.
• Welded brackets provide forenclosure mounting.
• Formed lip on door and enclosureexcludes flowing liquids andcontaminants.
• Stainless steel continuous hinge .ondoor may be removed by pulling thestainless steel hinge pin.
• Door is secured with easily operatedstainless steel clamps.
• Provision for padlocking.« Oil resistant gaskets are permanently
secured and mechanically retained." A removable 12 gauge inner panel is
included.• Collar studs are provided for
mounting inner panels.• A bonding stud is provided on the
door and a grounding stud isprovided in the enclosure.
» A literature pocket is provided for theinside of the door.
InnerPanel
Included
Finish* Cover and enclosure are natural
stainless steel with a smoothbrushed finish.
» Removable inner panel is finished inwhite powder coating.
Accessories« Additional inner panels...see page 380* Air conditioners...see page 347-353* Blowers...see page 357" Breather kits...see page 371* Door clamping hardware...see page 374* Door Stop kits...see page 389
" Drip Shield kits...see page 389* Enclosure stabilizers...see page 393
* Filter fans...see page 358-365* Floor Stand kits...see page 390
* H eate rs... see page 368-369* Lock kit...see page 375* Louvered ventilating plates...see page 392* Quick release clamp...see page 374
« Terminal kit assemblies...see page 383
* Thermostats...see page 377" Window kits...see page 387
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
100© Hammond Manufacturing
Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice
£ HAMMONDHr I
General AccessoriesPanels & Panel Accessories
www.hammfg.com
Panels for 1414 Series and PJ Series Enclosures14 gauge steel panels are finishedin white.
• Aluminum panels are 0.080 type5052 H-32 aluminum, unpainted.
" Panels and mounting hardware areincluded with 1414 Seriesenclosures.
" Mounting hardware is included withPJ Series enclosures, order panelseparately.
For Use WithSteel AluminumPart No. Part No.
14R050314R0505 14A050514R0705 14A0705
14R070714R0907 14A090714R090914R110514R1109 14A110914R1111
14R130714R1311 14A131114R150914R1513 14A1513
P1868 A1868P2068 A2068
PanelLength
4.88
4.886.75
6.758.75
8.7510.7510.7510.75
12.7512.75
14.7514.7516.8818.44
Width
2.88
4.884.88
6.886.88
8.884.888.88
10.88
6.8810.88
8.8812.8814.8814.44
1414Height Width
6
68
810
1012
1212
1414
1616—
4
66
88
106
1012
812
1014—
For Use WithPJ Series
Height Width— —
7.04 7.04 :8.94 7.06_ _
11.08 9.20• — • ' — '— —
13.08 11.20— —— _""'':: •:'«:*
15.08 13.20_ —
17.22 15.34
19.34 17.34 : :
20.94 16.94
Panels for 1418, 1447, and Series 2000 Wallmount Enclosures
Cl§sr«&iv,MWor\fDin«O3-P«/»
•
12 gauge steel finished in white." Larger panels have two, or four
formed flanges.• Some larger panels are 10 gauge.• Panels and mounting hardware are
included with 1418 and 1447 Seriesenclosures.
• Mounting hardware is included withSeries 2000 enclosures, order panelseparately.
,
PanelPart No.
18P09091
18P092118P13091
18P13131
18P17091
18P17131iwr 1 1 117
18P17171
18P211318P2117
18P212118P2709
18P271318P271718P272118P2727
t8P332118P332718P333318P392118P392718P393318P452118P452718P453318P573318P6927 ff!f'K':>m18P69331 Flat Panel
Length
9
913
1317..—
17
2121
2127
2727
2727
3333
3339
3939
4545
4557
6969
Technical references and DXF downloads available at www.hammfg.com
Width
9
219
13 : :
9
1317
1317
219
1317
2127
2127
3321
2733
2127
3333
2733
All dimensions
For Use With EnclosureHeight
12
1216
1620
2020
2424
2430
3030
3030
3636
3642
4242
4848
Width
12
ms^l 24 :12
1612
16IV20
«-vv 16
20
24 ;:>4P;112
' • . • • : • • " { : : ' . 1.6. • ' : i • i - - : ' . ;20
: . :24. HI III
30
: . - . ' ; . . . • :24:--:.30
36 vpSf24
30 3Si36
2430
48 3660
7272
in inches
36
."'!?"• 3036
unless specified otherwise
380© Hammond Manufacturing
Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice
*i HAMMONDmm E N C L O S U R E S
www.hammfg.com
Industry Definitons (NEMA Standards)
»3-3
?'&)
3
|Hi
|
Definitions Pertaining to Non-Hazardous LocationsType 1 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment, and to provide a degree ofprotection against falling dirt. NEMA 250-1997.
Type 2 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment, to provide a degree ofprotection against falling dirt, and to provide a degree ofprotection against dripping and light splashing of liquids.NEMA 250-1997.
Type 3 Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt, rain, sleet, snow,and windblown dust; and that will be undamaged by theexternal formation of ice on the enclosure. NEMA 250-1997.
Type 3R Enclosures constructed for either indoor oroutdoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt, rain, sleet,snow; and that will be undamaged by the external formationof ice on the enclosure. NEMA 250-1997.
Type 3S Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt, rain, sleet, snow, andwindblown dust; and in which the external mechanism(s)remain operable when ice laden. NEMA 250-1997.
Type 4 Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt, rain, sleet, snow,windblown dust, splashing water, and hose-directed water;and that will be undamaged by the external formation of iceon the enclosure. NEMA -250 1997.
Type 4X Enclosures constructed for either indoor oroutdoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt, rain, sleet,snow, windblown dust, splashing water, hose-directed water;and corrosion; and that will be undamaged by the externalformation of ice on the enclosure. NEMA -250 1997.
Type 5 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment; to provide a degree of protectionagainst falling dirt; against settling airborne dust, lint, fibers,and flyings; and to provide a degree of protection againstdripping and light splashing of liquids. NEMA 250-1997.
Type 6 Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt; against hose-directed water and the entry of water during occasionaltemporary submersion at a limited depth; and that will beundamaged by the external formation of ice on theenclosure. NEMA-250 1997.
Type 6P Enclosures constructed for either indoor or outdooruse to provide a degree of protection to personnel againstincidental contact with the enclosed equipment; to provide adegree of protection against falling dirt; against hose-directedwater and the entry of water during prolonged submersion ata limited depth;. and that will be undamaged by the externalformation of ice on the enclosure. NEMA-250 1997.
Type 12 Enclosures constructed (without knockouts) forindoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt; againstcirculating dust, lint, fibers, and flyings; and against drippingand light splashing of liquids. NEMA 250-1997
Type 12K Enclosures constructed (with knockouts) forindoor use to provide a degree of protection to personnelagainst incidental contact with the enclosed equipment; toprovide a degree of protection against falling dirt; againstcirculating dust, lint, fibers, and flyings; and against drippingand light splashing of liquids. NEMA 250-1997
Type 13 Enclosures constructed for indoor use to provide adegree of protection to personnel against incidental contactwith the enclosed equipment; to provide a degree of protectionagainst falling dirt; against circulating dust, lint, fibers, andflyings; and against spraying splashing, and seepage of water,oil and noncorrosive coolants. NEMA 250-1997
Definitions Pertaining To Hazardous (Classified)LocationsType 7 Enclosures constructed for indoor use in hazardouslocations classified as Class I, Division 1, Groups A, B, C, orD, as defined in NFPA70. NEMA 250-1997
Type 8 Enclosures constructed for either indoor or outdooruse in hazardous locations classified as Class I, Division 1,Groups A, B, C, or D, as defined in NFPA70. NEMA 250-1997
Type 9 Enclosures constructed for indoor use in hazardouslocations classified as Class II, Division 1,Groups E, F, or G,as defined in NFPA70. NEMA 250-1997
Type 10 Enclosures constructed to meet the requirementsof the Mine Safety and Health Administration, 30 CFR, Part18. NEMA 250-1997. NEMA 250-1997
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
398© Hammond Manufacturing
Quality Enclosures. Service Excellence.Canada: 519.822.2960 or 905.456.3770 USA: 716.631.8281 Data Subject to change without notice
top related