control panels - calpeda
Post on 15-Feb-2022
24 Views
Preview:
TRANSCRIPT
575
Control panels
QM, QT
576
Index
TYPE
Supply No. pumps Application
Bor
e-ho
le
Sub
mer
sibl
e
Sur
face
QM
M COMP
PFC-M
QML/A 1 D
T COMP
PFC-T
QTL/A 1 D
QTL 1 D FTE
QTL/A 1 ST FT
QTL/A 1 ST FT-RH
QTL 1 ST FTE
QTL 1 SS E
QTL 1 IS FTE
QML/A 2 D
QTL/A 2 D
QTL/A 2 ST FT
QTL/A 2 ST FT-RH
QML/A 3 D
QTL/A 3 D
QTL/A 3 ST FT
QTL/A 3 ST FT-RH
QML 1 VFT
QTL 1 VFT
QML 2 VFT
QTL 2 VFT
QML 1.1 VFT
QTL 1.1 VFT
QML 3 VFT
QTL 3 VFT
QTL 1.2 VFT
QTL 4 VFT
QTL 1.3 VFT
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1 ~ 3 ~ 1 2 3 4
577
Power Starting TypologyRotation speed
page
Fix
ed S
peed
D.O
.L.
Y/∆
Sof
t sta
rt
Impe
danc
e st
ator
Var
iabl
e sp
eed
Ele
ctro
mec
hani
cal
Ele
ctro
nic
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
578
579
579
580
580
581
581
582
582
583
584
584
585
586
586
587
587
588
588
589
589
590
590
591
591
592
592
593
593
594
594
595
0,3 ÷ 1,5
0,37 ÷ 2,2
0,37 ÷ 2,2
0,25 ÷ 1,5
0,37 ÷ 7,5
0,37 ÷ 5,5
0,25 ÷ 11
4 ÷ 30
5,5 ÷ 45
4 ÷ 92
5,5 ÷ 110
7,5 ÷ 132
5,5 ÷ 110
0,25 ÷ 1,5
0,37 ÷ 5,5
5,5 ÷ 45
4 ÷ 92
0,25 ÷ 1,5
0,37 ÷ 5,5
5,5 ÷ 45
4 ÷ 92
0,37 ÷ 3,7
0,37 ÷ 75
0,37 ÷ 3,7
0,37 ÷ 75
0,37 ÷ 3,7
0,37 ÷ 75
0,37 ÷ 3,7
0,37 ÷ 75
0,37 ÷ 75
0,37 ÷ 75
0,37 ÷ 75
kW
578
ConstructionControl panel with ON-OFF switch, circuit breaker and capacitor, for 1submersible pump with single-phase motor without built-in capacitor.
Technical data- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case.- ON-OFF switch with lamp- Thermal device- Capacitor- Terminal board- Cable glands
440179500044401795000744017960004
440179600094401799000144017960007440179900044401800000144018000000
Code
QM 4-16QM 5-20QM 5-25QM 6-20QM 7-25QM 7-30QM 8-25QM 8-30QM 10-40QM 12-35
Type
455677881012
Protector
max A
16 μF20 μF25 μF20 μF25 μF30 μF25 μF30 μF40 μF35 μF
Capacitor
450Vc
0,370,550,550,750,90,751,11,11,11,5
Motor 230V - 1~
kW
200x75x76200x75x76200x75x76200x75x76200x75x76200x75x76200x75x76200x75x76200x75x76200x75x76
Dimensions
HxBxP mm
QM Control panel for 1 pump with single-phase motor, direct starting
ConstructionControl panel with ON-OFF switch and capacitor, for 1 pump withsingle-phase motor without built-in capacitor.
Technical data- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case.- ON-OFF switch with lamp- Capacitor- Terminal board- Cable glands
QM Control panel for 1 pump with single-phase motor, direct starting
Control panels
44017940000440179500004401796000044017990000
Code
QM 6,3QM 20QM 25QM 30
Type
6,3 μF20 μF25 μF30 μF
Capacitor
450Vc
0,30,55 - 0,75
0,9 -1,10,9 -1,1
Motor 230V - 1~
kW
200x75x76200x75x76200x75x76200x75x76
Dimensions
HxBxP mm
579
ConstructionControl panel for controlling one pump with single-phase motor. Electroniccontrol of the operation and dry-running protection through the powerfactor (PF) control.The installation of level probes into the well is not required.It stops the pump in case of lack of air cushion in the pressure vessel(patented system).Displayed operating data and alarms available in four languages.
Technical data - Mains single-phase 230V ±10% 50/60 Hz.- Max output current: 18 A.- Ambient temperature from -5 °C to +40 °C.- Relative humidity: from 20% to 90% without condensation- Protection IP 55.- Control through pressure switch (pressure booster set).- Control through float switch (for filling a tank).- Alarm output signal.- Constructed in accordance with: IEC/EN 60439-1.
Setting- Min – Max voltage range.- Motor rated current.- Power factor (PF) value for dry-running protection.- Up to four programmable restarts in case of no water condition.
Alarms (with pump stop)- Mains failure.- Undervoltage and overvoltage.- Motor overload.- No water.- No air cushion in the pressure vessel.
Components- Thermoplastic case. - Capacitor. - Terminal board.- Display : 2x16 characters. - 6 button key board. - In/Out Cable glands.
On request: - RA 100 control panel for remote alarm.
PFC-M Control panel for 1 pump with single-phase motor, PF control
PFC-M 18-16PFC-M 18-20PFC-M 18-25PFC-M 18-30PFC-M 18-35PFC-M 18-40PFC-M 18-50PFC-M 18-60PFC-M 18-70
Type
1 - 181 - 181 - 181 - 181 - 181 - 181 - 181 - 181 - 18
Setting
A
16 μF20 μF25 μF30 μF35 μF40 μF50 μF60 μF70 μF
Capacitor
450Vc
0,370,550,550,750,751,11,51,52,2
Motor 230V - 1~
kW
220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110
Dimensions
HxBxP mm
ConstructionControl panel with ON-OFF switch and capacitor for 1 pump with single-phase motor.Suitable for use with LVBT board for level control.Protection is provided by means of a main bi-polar switch with a phase.protected against overload by means of a thermal element.
Technical data- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.- Control through pressure switch (pressure booster set).- Control through float switch (for filling a tank).
Components- Thermoplastic case.- ON-OFF switch with pilot lamp with thermal protector.- Capacitor.- Terminal board.- Terminals for LVBT board for level control.- In/Out cable glands.
On request:- LVBT card for level control.
M COMP Control panel for 1 pump with single-phase motor, direct starting
Control panels
LVBT
44020000000440200010004402001000044020011000440200210004402002300044020031000440200320004402004000044020041000440200520004402005300044020060000440200620004402006300044020081000
Code
M COMP 4-16M COMP 4-20M COMP 5-20M COMP 5-25M COMP 6-20M COMP 6-35M COMP 7-25M COMP 7-30M COMP 8-25M COMP 8-30M COMP 10-35M COMP 10-40M COMP 12-35M COMP 12-50M COMP 12-60M COMP 16-70
Type
4,54,555667788101012121216
Protector
max A
16 μF20 μF20 μF25 μF20 μF35 μF25 μF30 μF25 μF30 μF35 μF40 μF35 μF50 μF60 μF70 μF
Capacitor
450Vc
0,370,550,550,550,750,750,90,91,11,11,11,11,51,51,52,2
Motor 230V - 1~
kW
220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110220x210x110
Dimensions
HxBxP mm
1401313000014013480000140242500001401356000014013490000
T COMP 8T COMP 10T COMP 12T COMP 16T COMP 20
1 ÷ 87 ÷ 109 ÷ 1211 ÷ 1614 ÷ 20
A
0,37 ÷ 1,5---2,23
3,7 - 4
kW
0,5 ÷ 2,23 ÷ 3,7
45,57,5
kW
170x145x85230x180x155230x180x155230x180x155230x180x155
HxBxP mm
14054460000240544600002405446000114055740000
QML/A 1 D 12A-FAQML/A 1 D 12A-FA 20QML/A 1 D 12A-FA 25QML/A 1 D 3 FT
1 - 121 - 121 - 12
13 - 18
A
0,25 - 1,50,25 - 1,50,25 - 1,5
2,2 - 3
kW
250x205x105250x205x105250x205x105400x300x160
HxBxP mm
580
ConstructionControl panel and protection for 1 pump with three-phase motor.Arranged for the LVBT level control internal connection against dryrunning (T COMP8 model has the level control as a standard).Control pumps with pressure switch and float-type switch.
Technical data- Mains 230V or 400V ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Thermoplastic case.- ON-OFF control switch- Fuse holder - Contactor - Thermal relay- Fuses for change of voltage: 230 V or 400 V - Transformer- Terminals for pressure switch or float switch connection- Terminals for LVBT board (for T COMP 10,12,16,20 models)- Green LED indicator: voltage ON- Red LED indicator: thermic block- Cable glands
ON REQUEST:LVBT board for level control (for T COMP 10,12,16,20 models)
T COMP Control panel for 1 pump with three-phase motor
Code Type Protector Motor 230V - 3~ Motor 400V - 3~ Dimensions
ConstructionControl panel for 1 pump with single-phase motor, direct starting forpressure booster sets and submersible drainage pumps.Arranged for the capacitor internal connection (for pumps without built-in capacitor).For pressure booster sets:- with working time-measuring system that stops the pump in case of lack
of air cushion in the pressure vessel.- dry-running protection with float switch or level control probes. For submersible drainage pumps:- automatic operating test of the pump every set hours of inactivity (with
pump in the automatic operating mode).- Pump control with signals coming from:- 2 float switches: one for starting-up and stopping pump, one for the
alarm maximum level (optional).- 3 float switches: one for starting-up pump, one for stopping the pump
and one for the alarm maximum level (optional).Pump operation controlled by an electronic board type MPS 3000 withmicroprocessor which allows different modes of operation of the pump.
Technical data- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pressure switch connection.- Terminals for float switch connection against dry-running.- Cable glands.- Remote alarm control panel or volt free contact module.
ON REQUEST:- RA 100 - RA 100A control panel for remote alarm.- Volt free contact control panel Q-MSP 9M.
QML/A 1 D Control panel for 1 pump with single-phase motor, direct starting
Control panels
Code Type SettingMotor 230V - 1~ Dimensions
LVBT
14054470000140544800001405449000014054500000
QTL/A 1 D 12A-FAQTL/A 1 D 7,5 FTQTL/A 1 D 9,2 FTQTL/A 1 D 11 FT
1 - 1213 - 1817 - 2320 - 25
A
0,25 - 5,57,59,211
kW
250x205x105400x300x160400x300x160400x300x160
HxBxP mm
14058390000 PFC-T 16/A 1 - 16
A
0,37 - 5,5
kW
250x205x105
HxBxP mm
581
ConstructionControl panel for 1 pump with three-phase motor, direct starting forpressure booster sets and submersible drainage pumps.For pressure booster sets:- with working time-measuring system that stops the pump in case of lack
of air cushion in the pressure vessel.- dry-running protection with float switch or level control probes. For submersible drainage pumps:- automatic operating test of the pump every set hours of inactivity (with
pump in the automatic operating mode).- Pump control with signals coming from:- 2 float switches: one for starting-up and stopping pump, one for the
alarm maximum level (optional).- 3 float switches: one for starting-up pump, one for stopping the pump
and one for the alarm maximum level (optional).Pump operation controlled by an electronic board type MPS 3000 withmicroprocessor which allows different modes of operation of the pump.
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case (metallic for 7,5-9,2-11kW).- Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Starting contactor and thermal relay (for 7,5-9,2-11kW).- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pressure switch connection.- Terminals for float switch connection against dry-running.- Terminals for remote signals- Cable glands.
ON REQUEST:- RA 100 - RA 100A control panel for remote alarm.- Volt free contact control panel Q-MSP 9M.
QTL/A 1 D Control panel for 1 pump with three-phase motor, direct starting
Construction Control panel for controlling 1 pump with three-phase motor. Electroniccontrol of the operation and dry-running protection through the powerfactor (PF) control.The installation of level probes into the well is not required.It stops the pump in case of lack of air cushion in the pressure vessel Displayed operating data and alarms, available in four languages.
Technical data - Mains three-phase 400V - 3 ~ ±10% 50/60 Hz- Output current: 16 A- Ambient temperature from -5 °C to +40 °C.- Relative humidity: from 20% to 90% without condensation- Protection IP 55.- Control through pressure switch (pressure booster set)- Control through float switch (for filling a tank)- Alarm output signal- Constructed in accordance with: IEC/EN 60439-1.
Setting- Min – Max voltage range- Motor rated current- Power factor (PF) value for dry-running protection - Up to four programmable restarts in case of no water condition
Alarms (with pump stop)- Phase failure - Wrong phase sequence- Undervoltage and overvoltage- Motor overload- No water- No air cushion in the pressure vessel
Components- Thermoplastic case. - Terminal board. - Display : 2x16 characters. - 6 button key board. - In/Out Cable glands.
On request: - RA 100 control panel for remote alarm.
PFC-T Control panel for 1 pump with three-phase motor, PF control
Control panels
Code Type SettingMotor 400V - 3~ Dimensions
Code Type SettingMotor 400V - 3~ Dimensions
14054510000140545200001405453000014054540000140545500001405456000014054570000140545800001405459000014054600000
QTL/A 1 ST 5,5 FTQTL/A 1 ST 7,5 FTQTL/A 1 ST 11 FTQTL/A 1 ST 15 FTQTL/A 1 ST 18,5 FTQTL/A 1 ST 22 FTQTL/A 1 ST 30B FTQTL/A 1 ST 30A FTQTL/A 1 ST 37 FTQTL/A 1 ST 45 FT
11 - 1512 - 1716 - 2423 - 3130 - 3935 - 4342 - 5555 - 6561 - 8480 - 105
5,57,5
9,2 - 1115
18,52230303745
kW A600x400x200600x400x200600x400x200600x400x200600x400x200700x500x200700x500x200700x500x200800x600x250800x600x250
HxBxP mm
140298200001405892000014058930000140502500001403763000014058940000140292200001405895000014058960000
QTL 1 D 4 FTEQTL 1 D 5,5 FTEQTL 1 D 7,5 FTEQTL 1 D 9,2 FTEQTL 1 D 11 FTEQTL 1 D 15 FTEQTL 1 D 18,5 FTEQTL 1 D 22 FTEQTL 1 D 30 FTE
6,3 - 109 - 1213 - 1817 - 2320 - 2524 - 3232 - 3835 - 5046 - 65
A
45,57,59,21115
18,52230
kW
400x300x160400x300x160400x300x160400x300x160400x300x160500x350x200500x350x200500x350x200500x350x200
HxBxP mm
582
QTL/A 1 ST FT Control panel for 1 pump with three-phase motor, Y/Δ starting
ConstructionControl panel for 1 pump with three-phase motor, Y/Δ starting forpressure booster sets, with working time-measuring system that stops thepump in case of lack of air cushion in the pressure vessel.Pump operation controlled by an electronic card type MPS 3000 withmicroprocessor with different pump operating modes.Dry-running protection with float switch or level control probes.
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Starting contactors. - Thermal relay. - Transformer.- Electronic board MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for motor connection.- Terminals for connection pressure switch of pump operating.- Terminals for float switch connection against dry-running.- Terminals for remote signals- Cable glands.
ON REQUEST:- RA 100 - RA 100A control panel for remote alarm.- Voltmeter. - Ammeter.
Code Type Motor 400V - 3~Power Current
Dimensions
ConstructionElectromechanical control panel for 1 pump with three-phase motor, directstarting.Operating signals by E 1000 led card.Dry-running protection with float switch.Construction with SRLE level control for probes connection against dry-running on request .
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch.- Power circuit fuses. - Fuses for auxiliary circuit.- Starting contactor. - Thermal relay- Transformer. - E 1000 led card.- Terminals for connection pump operating signal.- Terminals for float switch connection against dry-running.- Cable glands.
ON REQUEST:- RLE level control for probes against dry running- RLE level control for pump operating probes.- Voltmeter. - Ammeter.
QTL 1 D FTE Control panel for 1 pump with three-phase motor, direct starting
Control panels
Code Type SettingMotor 400V - 3~ Dimensions
1405461000014054620000140546300001405464000014054650000140546600001405467000014054680000140546900001405470000014054710000140547200001405473000014054740000
QTL/A 1 ST 4 FT-RHQTL/A 1 ST 5,5 FT-RHQTL/A 1 ST 7,5 FT-RHQTL/A 1 ST 11 FT-RHQTL/A 1 ST 15 FT-RHQTL/A 1 ST 18,5 FT-RHQTL/A 1 ST 22 FT-RHQTL/A 1 ST 30B FT-RHQTL/A 1 ST 30A FT-RHQTL/A 1 ST 37 FT-RHQTL/A 1 ST 45 FT-RHQTL/A 1 ST 55 FT-RHQTL/A 1 ST 75 FT-RHQTL/A 1 ST 92 FT-RH
7 - 1111 - 1512 - 1716 - 2423 - 3130 - 3935 - 4342 - 5555 - 6561 - 84
80 - 105100 - 125120 - 150155 - 255
45,57,5
9,2 - 1115
18,52230303745557592
kW A600x400x200600x400x200600x400x200600x400x200600x400x200600x400x200700x500x250700x500x250700x500x250800x600x250800x600x250800x600x250900x600x3001100x700x250
HxBxP mm
583
QTL/A 1 ST FT-RH Control panel for 1 submersible drainage pump with three-phase motor, Y/Δ starting
Control panels
ConstructionControl panel with protection for 1 submersible drainage pump with three-phasemotor, Y/Δ starting.Operation managed by the MPS 3000 electronic circuit board that has thefollowing functions:- automatic operating test of the pump every set hours of inactivity (with
pump in the automatic operating mode).- Pump control with signals coming from:
- 2 float switches: for starting-up and stopping pump, for the alarm(maximum level is optional).
- 3 float switches: for starting-up pump, for stopping the pump and forthe alarm (maximum level is optional).
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Line selector switch with door-locking device.- Power line fuses. - Auxiliary circuit fuses. - Contactors.- Y/Δ timer. - Thermal relay. - Level regulator.- MPS 3000 type circuit board with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Connection terminals for float switches or level probes.- Connection terminals for water seepages probe.- Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 9M.- RA 100 - RA 100A control panel for remote alarm.- Voltmeter. - Ammeter.
Code Type Motor 400V - 3~Power Current
Dimensions
1405905000014053880000140284400001405906000014045900000140590700001405908000014059090000140591000001405911000014059120000
QTL 1 SS 7,5 EQTL 1 SS 15 EQTL 1 SS 22 EQTL 1 SS 30 EQTL 1 SS 37 EQTL 1 SS 45 EQTL 1 SS 55 EQTL 1 SS 63 EQTL 1 SS 75 EQTL 1 SS 90 EQTL 1 SS 132 E
173045607585110125142190245
max A
7,59,2 - 11 - 15
18,5 - 2226 - 30
374555637590
110 - 132
kW700x500x250700x500x250700x500x250900x600x300900x600x300900x600x300900x600x3001100x700x3001100x700x3001200x800x4001200x800x400
HxBxP mm
1405897000014058980000140292000001405899000014029440000140317100001405900000014048380000140485200001404705000014059010000140590200001405903000014059040000
QTL 1 ST 5,5 FTEQTL 1 ST 7,5 FTEQTL 1 ST 11 FTEQTL 1 ST 15 FTEQTL 1 ST 18,5 FTEQTL 1 ST 22 FTEQTL 1 ST 30B FTEQTL 1 ST 30A FTEQTL 1 ST 37 FTEQTL 1 ST 45 FTEQTL 1 ST 55 FTEQTL 1 ST 75 FTEQTL 1 ST 92 FTEQTL 1 ST 110 FTE
11 - 1512 - 1716 - 2423 - 3130 - 3935 - 4342 - 5555 - 6561 - 84
80 - 105100 - 125120 - 160140 - 198180 - 250
5,57,5
9,2 - 1115
18,52230303745557592110
500x350x200500x350x200500x350x200500x350x200500x350x200600x400x200600x400x200600x400x200700x500x200700x500x200700x500x200800x600x250800x600x250800x600x250
HxBxP mmkW A
584
QTL 1 SS E Control panel for 1 pump with three-phase motor, start/stop with soft starter
ConstructionControl panel for 1 pump with three-phase motor, start/stop with soft starter.Operating signals on E 1000 led board.Application: control of submersible motor with great cable length andsurface motors.Dry-running protection with float switch.Construction with SRLE level control for probes connection against dry-running on request .
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Soft starter - Transformer.- By pass contactors (built into the soft starter) - E 1000 led board.- Terminals for float switch or level probes connection for pump operating.- Terminals for float switch or level probes connection against dry-running.- Cable glands.
ON REQUEST:- RLE level control for connection level probes of pump operating.- RLE level control for probes against dry running.- Voltmeter. - Ammeter.
Code Type Max currentoutpu
Motor 400V - 3~ Dimensions
QTL 1 ST FTE Control panel for 1 pump with three-phase motor, Y/Δ starting
Control panels
ConstructionElectromechanical control panel for 1 pump with three-phase motor, Y/Δstarting.Operating signals by E 1000 led board.Dry-running protection with float switch.Construction with SRLE level control for probes connection againstdry-running on request .
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - Starting contactors. - Thermal relay.- Y/Δ timer. - Transformer. - E 1000 led board.- Terminals for motor connection.- Terminals for connection of pump operating signal.- Terminals for float switch connection against dry-running.- Cable glands.
ON REQUEST:- RLE level control for probes against dry running.- RLE level control for pump operating probes.- Voltmeter. - Ammeter.
Code Type DimensionsMotor 400V - 3~Power Current
QTL 1 IS 5,5 FTE-2RLQTL 1 IS 7,5 FTE-2RLQTL 1 IS 11 FTE-2RLQTL 1 IS 15 FTE-2RLQTL 1 IS 18,5 FTE-2RLQTL 1 IS 22 FTE-2RLQTL 1 IS 30 FTE-2RLQTL 1 IS 37 FTE-2RLQTL 1 IS 45 FTE-2RLQTL 1 IS 55 FTE-2RLQTL 1 IS 75 FTE-2RLQTL 1 IS 92 FTE-2RLQTL 1 IS 110 FTE-2RL
11 - 1512 - 1716 - 2423 - 3130 - 3935 - 4342- 6561 - 8480 - 105100 - 125120 - 160140 - 198180 - 250
5,57,5
9,2 - 1115
14059130000140591400001405915000014052700000140591600001405917000014059180000140591900001405920000014059210000140592200001405923000014059240000
18,522303745557592110
kW A HxBxP mm
585
QTL 1 IS FTE Control panel for 1 pump with three-phase motor, with Stator Impedence starter
Control panels
ConstructionElectromechanical control panel for 1 submersible pump with three-phasemotor, with Stator Impedence starter.Operating signals on led board type E 1000.Application : submersible motors control with great cable length. Construction with SRLE level control for probes connection against dry-running .
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Stator Impedence - By pass contactors- Transformer. - E 1000 led board. - RLE level control for connection level probes of pump control.- RLE level control for probes against dry running.- Terminals for connection level probes or float switch for operating pump.- Terminals for level probes or float switch connection against dry-running.- Cable glands.
ON REQUEST:- Voltmeter. - Ammeter.
Code Type Motor 400V - 3~Power Current
Dimensions
14054760000 QTL/A 2 D 12A-FA 1 - 12
max A
0,25 - 5,5
kW
310x235x125
HxBxP mm
1405475000024054750000240547500012405475000224054750003
14055750000
QML/A 2 D 12A-FAQML/A 2 D 12A-FA 20QML/A 2 D 12A-FA 25QML/A 2 D 12A-FA 30-85QML/A 2 D 12A-FA 35-85QML/A 2 D 3 FT
1 - 121 - 121 - 121 - 121 - 1213 - 18
max A
0,25 - 1,50,25 - 1,50,25 - 1,50,25 - 1,50,25 - 1,5
2,2 - 3
kW
310x235x125310x235x125310x235x125395x315x135395x315x135500x350x160
HxBxP mm
586
ConstructionControl panel for 2 pumps with three-phase motor, direct starting forpressure booster sets and submersible drainage pumps.For pressure booster sets:- with working time-measuring system that stops the pump in case of lack
of air cushion in the pressure vessel.- dry-running protection with float switch or level control probes. For submersible drainage pumps:- pump changing at every pump start.- working pumps changing after 30 minutes of uninterrupted operation.- automatic operating test of each individual pump every set hours of
inactivity (with pumps in the automatic functioning mode).- Pump control with signals coming from:
- 3 float switches: for starting-up and stopping pump 1, for starting-upand stopping pump 2, for the alarms (maximum level is optional).
- 4 float switches: for starting-up pump 1, for starting up pump 2, forstopping the pumps and for the alarms (maximum level is optional).
Pump operation controlled by an electronic board type MPS 3000 withmicroprocessor which allows different modes of operation of the pump.
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pressure switch connection.- Terminals for float switch or flow switch connection against dry-running.- Terminals for remote signals- Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.
QTL/A 2 D Control panel for 2 pumps with three-phase motor, direct starting
Control panels
Code Type SettingMotor 400V - 3~ Dimensions
ConstructionControl panel for 2 pumps with single-phase motor, direct starting forpressure booster sets and submersible drainage pumps.Arranged for the capacitor internal connection (for pumps without built-in capacitor).For pressure booster sets:- with working time-measuring system that stops the pump in case of lack
of air cushion in the pressure vessel.- dry-running protection with float switch or level control probes. For submersible drainage pumps:- pump changing at every pump start.- working pumps changing after 30 minutes of uninterrupted operation.- automatic operating test of each individual pump every set hours of
inactivity (with pumps in the automatic functioning mode).- Pump control with signals coming from:
- 3 float switches: for starting-up and stopping pump 1, for starting-upand stopping pump 2, for the alarms (maximum level is optional).
- 4 float switches: for starting-up pump 1, for starting up pump 2, forstopping the pumps and for the alarms (maximum level is optional).
Pump operation controlled by an electronic board type MPS 3000 withmicroprocessor which allows different modes of operation of the pump.
Technical data- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case.- Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Starting relay.- Two capacitor (on request)- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pressure switch connection.- Terminals for float switch or float switch connection against dry-running.- Terminals for remote signals- Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.
QML/A 2 D Control panel for 2 pumps with single-phase motor, direct starting
Code Type ProtectorMotor 230V - 1~ Dimensions
14054770000140547800001405479000014054800000140548100001405482000014054830000140548400001405485000014054860000
QTL/A 2 ST 5,5 FTQTL/A 2 ST 7,5 FTQTL/A 2 ST 11 FTQTL/A 2 ST 15 FTQTL/A 2 ST 18,5 FTQTL/A 2 ST 22 FTQTL/A 2 ST 30B FTQTL/A 2 ST 30A FTQTL/A 2 ST 37 FTQTL/A 2 ST 45 FT
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
5,57,5
9,2 - 1115
18,52230303745
700x500x200700x500x200700x500x200700x500x200700x500x200900x600x250900x600x250900x600x250
1100x700x2501100x700x250
HxBxP mmkW A
1405487000014054880000140548900001405490000014054910000140549200001405493000014054940000140549500001405496000014054970000140549800001405499000014055000000
QTL/A 2 ST 4 FT-RHQTL/A 2 ST 5,5 FT-RHQTL/A 2 ST 7,5 FT-RHQTL/A 2 ST 11 FT-RHQTL/A 2 ST 15 FT-RHQTL/A 2 ST 18,5 FT-RHQTL/A 2 ST 22 FT-RHQTL/A 2 ST 30B FT-RHQTL/A 2 ST 30A FT-RHQTL/A 2 ST 37 FT-RHQTL/A 2 ST 45 FT-RHQTL/A 2 ST 55 FT-RHQTL/A 2 ST 75 FT-RHQTL/A 2 ST 92 FT-RH
7 - 1111 - 1512 - 1716 - 2423 - 3130 - 3935 - 4342 - 5555 - 6561 - 84
80 - 105100 - 125120 - 150155 - 255
45,57,5
9,2 - 1115
18,52230303745557592
kW A700x500x200700x500x200700x500x200700x500x200700x500x200700x500x200900x600x250900x600x250900x600x2501100x700x2501100x700x2501200x800x3001200x800x3001400x800x400
HxBxP mm
587
ConstructionControl panel for 2 pumps with three-phase motor, Y/Δ starting, forpressure booster sets, with working time-measuring system that stops thepump in case of lack of air cushion in the pressure vessel.Pump operation cascade mode controlled by an electronic board typeMPS 3000 with microprocessor which allows different operation modes: Dry-running protection with float switch or level control probes.
Technical data- Mains 400V ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - Starting contactors. - Thermal relay. - Y/Δ timers. - Transformer.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pressure switch connection.- Terminals for float switch or float switch connection against dry-running.- Terminals for remote signals - Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.- Voltmeter. - Ammeter.
QTL/A 2 ST FT Control panel for 2 pumps with three-phase motor, Y/Δ starting
Control panels
Code Type DimensionsMotor 400V - 3~Power Current
QTL/A 2 ST FT-RH Electric control panel for 2 drainage pumps with three-phase motor, Y/Δ starting
ConstructionControl panel with protection for 2 submersible drainage pumps with three-phase motor, Y/∆ starting.Operation managed by the MPS 3000 electronic circuit board that has thefollowing functions:- pump changing at every pump start.- working pumps changing after 30 minutes of uninterrupted operation.- automatic operating test of each individual pump every set hours of
inactivity (with pumps in the automatic functioning mode).- Pump control with signals coming from:
- 3 float switches: for starting-up and stopping pump 1, for starting-upand stopping pump 2, for the alarms (maximum level is optional).
- 4 float switches: for starting-up pump 1, for starting up pump 2, forstopping the pumps and for the alarms (maximum level is optional).
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch.- Power line fuses. - Auxiliary circuit fuses. - Contactors. - Y/∆ timers. - Level regulator.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for float switches.- Connection terminals for thermal protectors.- Connection terminals for water seepages probe.- Connection terminals for the RA 100, RA 100A type remote alarm
control panel or volt free contact module.- Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.- Voltmeter. - Ammeter.
Code Type Motor 400V - 3~Power Current
Dimensions
14055010000 QML/A 3 D 12A-FA 1 - 12
max A
0,25 - 1,5
kW
395x315x135
HxBxP mm
14055020000 QTL/A 3 D 12A-FA 1 - 12
max A
0,37 - 5,5
kW
395x315x135
HxBxP mm
588
Control panels
ConstructionControl panel for 3 pumps with single-phase motor, direct starting forpressure booster sets, with working time-measuring system that stops thepump in case of lack of air cushion in the pressure vessel.Pump operation cascade mode controlled by an electronic board typeMPS 3000 with microprocessor which allows different operation modes.Dry-running protection with float switch or level control probes.
Technical data- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Starting relay. - Circuit breaker.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pressure switch connection.- Terminals for float switch or float switch connection against dry-running.- Terminals for remote signals- Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.
QML/A 3 D Control panel for 3 pumps with single-phase motor, direct starting
Code Type SettingMotor 230V - 1~ Dimensions
ConstructionControl panel for 3 pumps with three-phase motor, direct starting, forpressure booster sets and submersible drainage pumps.For pressure booster sets:- with working time-measuring system that stops the pump in case of lack
of air cushion in the pressure vessel.- dry-running protection with float switch or level control probes. For submersible drainage pumps:- changes pumps at every pump start.- changes working pumps after 30 minutes of uninterrupted operation.- automatic functioning test of each individual pump every set hours of
inactivity (with pumps in the automatic functioning mode).- Pump control with signals coming from:
- 4 float switches: for starting-up and stopping pump, for the alarm(maximum level is optional).
- 5 float switches: for starting-up pump, for stopping the pumps and forthe alarm (maximum level is optional).
Pump operation controlled by an electronic board type MPS 3000 withmicroprocessor which allows different modes of operation of the pump.
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Thermoplastic case. - Door lock master switch.- Fuses for power line. - Fuses for auxiliary circuit.- Starting contactors. - Thermal relay.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals forpressure switch connection.- Terminals for float switch or flow switch connection against dry-running.- Terminals for remote signals - Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.
QTL/A 3 D Control panel for 3 pumps with three-phase motor, direct starting
Code Type SettingMotor 400V - 3~ Dimensions
14055030000140550400001405505000014055060000140550700001405508000014055090000140551000001405511000014055120000
QTL/A 3 ST 5,5 FTQTL/A 3 ST 7,5 FTQTL/A 3 ST 11 FTQTL/A 3 ST 15 FTQTL/A 3 ST 18,5 FTQTL/A 3 ST 22 FTQTL/A 3 ST 30B FTQTL/A 3 ST 30A FTQTL/A 3 ST 37 FTQTL/A 3 ST 45 FT
11 - 15
12 - 17
16 - 24
23 - 31
30 - 39
35 - 43
42 - 55
55 - 65
61 - 84
80 - 105
5,57,5
9,2 - 1115
18,52230303745
700x500x200700x500x200800x600x250800x600x250
1000x600x2501100x700x2501200x800x3001200x800x3001400x800x4001400x800x400
HxBxP mmkW A
1405513000014055140000140551500001405516000014055170000140551800001405519000014055200000140552100001405522000014055230000140552400001405525000014055260000
QTL/A 3 ST 4 FT-RHQTL/A 3 ST 5,5 FT-RHQTL/A 3 ST 7,5 FT-RHQTL/A 3 ST 11 FT-RHQTL/A 3 ST 15 FT-RHQTL/A 3 ST 18,5 FT-RHQTL/A 3 ST 22 FT-RHQTL/A 3 ST 30B FT-RHQTL/A 3 ST 30A FT-RHQTL/A 3 ST 37 FT-RHQTL/A 3 ST 45 FT-RHQTL/A 3 ST 55 FT-RHQTL/A 3 ST 75 FT-RHQTL/A 3 ST 92 FT-RH
7 - 1111 - 1512 - 1716 - 2423 - 3130 - 3935 - 4342 - 5555 - 6561 - 84
80 - 105100 - 125120 - 150155 - 255
45,57,5
9,2 - 1115
18,52230303745557592
kW A700x500x200700x500x200700x500x200800x600x250800x600x2501000x600x2501100x700x2501200x800x3001200x800x3001400x800x4001400x800x4001600x800x4001600x1000x4001600x1000x400
HxBxP mm
589
Control panels
ConstructionControl panel for 3 pumps with three-phase motor, Y/Δ starting, forpressure booster sets, with working time-measuring system that stops thepump in case of lack of air cushion in the pressure vessel.Pump operation cascade mode controlled by an electronic board typeMPS 3000 with microprocessor which allows different operation modes:standard, emergency and timed.Dry-running protection with float switch or level control probes.
Technical data- Mains 400V ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 55.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - Starting contactors.- Thermal relay. - Y/Δ timers. - Transformer.- Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Terminals for pumps connection.- Terminals for pressure switch connection.- Terminals for float switch or flow switch connection against dry-running.- Terminals for remote signals - Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm.- Voltmeter. - Ammeter.
QTL/A 3 ST FT Control panel for 3 pumps with three-phase motor, Y/Δ starting
Code Type DimensionsMotor 400V - 3~Power Current
QTL/A 3 ST FT-RH Electric control panel for 3 drainage pumps with three-phase motor, Y/Δ starting
ConstructionControl panel with protection for 3 submersible drainage pumps with three-phase motor, Y/∆ starting.Operation managed by the MPS 3000 electronic circuit board thatincorporates the following functions:- changes pumps at every pump start.- changes working pumps after 30 minutes of uninterrupted operation.- automatic functioning test of each individual pump every set hours of
inactivity (with pumps in the automatic functioning mode).- Pump control with signals coming from:
- 4 float switches: for starting-up and stopping pump, for the alarm(maximum level is optional).
- 5 float switches: for starting-up pump, for stopping the pumps and forthe alarm (maximum level is optional).
Technical data- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C. - Protection IP 55.
Components- Metal case. - Line selector switch with door-locking device.- Power line fuses. - Auxiliary circuit fuses. - Contactors. - Y/∆ timers. - Electronic board type MPS 3000 with microprocessor.- Terminals for pressure trasducer / level probes.- Connection terminals for thermal protector.- Connection terminals for the RA 100 - RA 100A type.- Connection terminals for float switches.- Connection terminals for water seepages probe.- Cable glands.
ON REQUEST:- Volt free contact control panel Q-MSP 13M.- RA 100 - RA 100A control panel for remote alarm .- Voltmeter. - Ammeter.
Code Type Motor 400V - 3~Power Current
Dimensions
14059250000
14059260000
14059270000
14050260000
QML 1 VFT 0,4QML 1 VFT 0,75QML 1 VFT 1,5QML 1 VFT 2,2
2,44,27,510
0,37 - 0,450,55 - 0,751,1 - 1,5
2,2
500x350x200500x350x200500x350x200500x350x200
QTL 1 VFT 0,4QTL 1 VFT 0,75QTL 1 VFT 1,5QTL 1 VFT 2,2QTL 1 VFT 4QTL 1 VFT 5,5QTL 1 VFT 7,5QTL 1 VFT 11QTL 1 VFT 15QTL 1 VFT 18,5QTL 1 VFT 22QTL 1 VFT 30QTL 1 VFT 37QTL 1 VFT 45QTL 1 VFT 55QTL 1 VFT 75
1,52,34,15,59,514,317
27,733
46,361,574,588106145173
0,40,55 - 0,751,1 - 1,5
2,23 - 45,57,5
9,2 - 1115
18,5223037455575
500x350x200500x350x200500x350x200500x350x200500x350x200600x400x250600x400x250700x500x250700x500x250800x600x250800x600x250900x600x250
1100x700x3001200x800x3001200x800x3001200x800x300
14046510000140465200001404653000014046540000140465500001404656000014046570000140465800001404659000014046600000140466100001404662000014046630000140466400001404665000014046660000
590
ConstructionSingle-phase mains supply control panel with frequency converter for 1pump with three-phase 230V variable speed motor, for constant pressurebooster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor.
Technical data- Mains single-phase 230V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit.- EMC filter. - Frequency converter. - MPS 4000 electronic card.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling.- Terminals board. - Terminals for remote signals- Pressure transducer - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 9M.- RA 100 control panel for remote alarm.
QML 1 VFT Control panel for 1 pump with variable speed three-phase motor.
Control panels
Code Type Max currentoutputmax A
Motor 230V - 3~
kW
Dimensions
HxBxP mm
ConstructionControl panel with frequency converter for 1 pump with three-phasevariable speed motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit.- EMC filter. - Frequency converter. - MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling.- Terminals board. - Terminals for remote signals- Pressure transducer - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 9M.- RA 100 control panel for remote alarm.
QTL 1 VFT Control panel for 1 pump with variable speed three-phase motor
Code Type Motor 400V - 3~
kW
Dimensions
HxBxP mm
Max currentoutpumax A
14059280000
14048320000
14047020000
14059290000
QML 2 VFT 0,45QML 2 VFT 0,75QML 2 VFT 1,5QML 2 VFT 2,2
0,37 - 0,450,55 - 0,751,1 - 1,5
2,2
600x400x250600x400x250600x400x250600x400x250
14046670000140466800001404669000014046700000140467100001404672000014046730000140467400001404675000014046760000140467700001404678000014046790000140468000001404681000014046820000
2,4x24,2x27,5x210x2
QTL 2 VFT 0,45QTL 2 VFT 0,75QTL 2 VFT 1,5QTL 2 VFT 2,2QTL 2 VFT 4QTL 2 VFT 5,5QTL 2 VFT 7,5QTL 2 VFT 11QTL 2 VFT 15QTL 2 VFT 18,5QTL 2 VFT 22QTL 2 VFT 30QTL 2 VFT 37QTL 2 VFT 45QTL 2 VFT 55QTL 2 VFT 75
0,37 - 0,450,55 - 0,751,1 - 1,5
2,23 - 45,57,5
9,2 - 1115
18,5223037455575
600x400x250600x400x250600x400x250600x400x250600x400x250700x500x250700x500x250900x600x250900x600x2501200x800x3001200x800x3001200x800x3001600x1000x4002100x1400x5002100x1400x5002100x1400x500
1,5x22,3x24,1x25,5x29,5x214,3x217x2
27,7x233x2
46,3x261,5x274,5x288x2106x2145x2173x2
591
ConstructionSingle-phase mains supply control panel with frequency converter for 2pumps with three-phase 230V variable speed motor, for constantpressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor alternating the starting order at each start.
Technical data- Mains single-phase 230V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - EMC filter.- Frequency converter (1 for each pump).- MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling.- Terminals board. - Terminals for remote signals- Pressure transducer - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 9M..- RA 100 control panel for remote alarm.
QML 2 VFT Control panel for 2 pumps with variable speed three-phase motor
Control panels
Code Type Max currentoutputmax A
Motor 230V - 3~
kW
Dimensions
HxBxP mm
ConstructionControl panel with frequency converter for 2 pump with three-phasevariable speed motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit.- EMC filter. - Frequency converter.- MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 9M.- RA 100 control panel for remote alarm.
QTL 2 VFT Control panel for 2 pumps with variable speed three-phase motor
Code Type Motor 400V - 3~
kW
Dimensions
HxBxP mm
Max currentoutputmax A
14058910000
14047430000
14058510000
14050290000
QML 1.1 VFT 0,45 - D 0,45QML 1.1 VFT 0,75 - D 0,75QML 1.1 VFT 1,5 - D 1,5QML 1.1 VFT 2,2 - D 2,2
0,37 - 0,450,55 - 0,751,1 - 1,5
2,2
600x400x250600x400x250600x400x250600x400x250
140593000001404746000014047230000140471300001405984000014047160000140471200001404703000014048390000140482100001404834000014055630000140593100001405932000014059330000140593400001405935000014059360000
QTL 1.1 VFT 0,45 - D 0,45QTL 1.1 VFT 0,75 - D 0,75QTL 1.1 VFT 1,5 - D 1,5QTL 1.1 VFT 2,2 - D 2,2QTL 1.1 VFT 4 - D 3QTL 1.1 VFT 4 - D 4QTL 1.1 VFT 5,5 - D 5,5QTL 1.1 VFT 7,5 - ST 7,5QTL 1.1 VFT 11 - ST 11QTL 1.1 VFT 15 - ST 15QTL 1.1 VFT 18,5 - ST 18,5QTL 1.1 VFT 22 - ST 22QTL 1.1 VFT 30 - ST 30BQTL 1.1 VFT 30 - ST 30AQTL 1.1 VFT 37 - ST 37QTL 1.1 VFT 45 - ST 45QTL 1.1 VFT 55 - ST 55QTL 1.1 VFT 75 - ST 75
0,37 - 0,450,55 - 0,75
1,1 - 1,52,234
5,57,5
9,2 - 1115
18,522303037455575
600x400x250600x400x250600x400x250600x400x250600x400x250600x400x250700x500x250800x600x250800x600x250800x600x250
900x600x250 900x600x2501000x800x2501000x800x2501200x800x3001200x800x3001200x800x3001200x800x300
2,44,27,510
1,52,34,15,59,59,514,317
27,733
46,361,574,574,588106145173
1 - 1,61,6 - 2,52,5 - 44 - 6,54 - 6,56,3 - 109 - 1411 - 1716 - 2422 - 3130 - 3935 - 4342 - 5555 - 6561 - 8480 - 105100 - 125120 - 160
592
ConstructionSingle-phase mains supply control panel with frequency converter for 2pumps, one with three-phase 230V variable speed motor and one withfixed speed single-phase motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor.
Technical data- Mains single-phase 230V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit.- EMC filter. - Frequency converter.- Starting contactors of the second pump. - Transformer.- MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 9M.- RA 100 control panel for remote alarm.
QML 1.1 VFT Control panel for 1 variable speed pump and 1 fixed speed pump
Control panels
Code Type Max currentoutputmax A
Motor 230V - 3~
kW
Dimensions
HxBxP mm
ConstructionControl panel with frequency converter for 2 pumps with three-phasemotor, one with variable speed and one with fixed speed motor, forconstant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - EMC filter. - Frequency converter.- Starting contactors of the second pump. - Timer (Y/Δ) from 7,5 kW. - Transformer. - MPS 4000 electronic card.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 9M.- RA 100 control panel for remote alarm.
QTL 1.1 VFT Control panel for 1 variable speed pump and 1 fixed speed pump
Code Type Motor400V - 3~
kW
Dimensions
HxBxP mm
Max current output(Variable) (Fixed)max A max A
14059370000
14059380000
14059390000
14056970000
QML 3 VFT 0,45QML 3 VFT 0,75QML 3 VFT 1,5QML 3 VFT 2,2
0,37 - 0,450,55 - 0,751,1 - 1,5
2,2
700x500x250700x500x250700x500x250800x600x250
14059400000140488400001404693000014047140000140470400001404825000014049760000140472800001405035000014054370000140471500001404727000014052180000140594100001405942000014059430000
QTL 3 VFT 0,45QTL 3 VFT 0,75QTL 3 VFT 1,5QTL 3 VFT 2,2QTL 3 VFT 4QTL 3 VFT 5,5QTL 3 VFT 7,5QTL 3 VFT 11QTL 3 VFT 15
QTL 3 VFT 22QTL 3 VFT 30QTL 3 VFT 37QTL 3 VFT 45QTL 3 VFT 55QTL 3 VFT 75
700x500x250700x500x250700x500x250800x600x250800x600x250 800x600x250800x600x2501700x800x3001700x800x300
1700x1000x400QTL 3 VFT 18,5 1700x1000x400
1700x1000x4001200x600x300n31400x800x400n3
A richiestaA richiesta
2,4x34,2x37,5x310x3
1,5x32,3x34,1x35,5x39,5x314,3x317x3
27,7x333x3
46,3x361,5x374,5x388x3106x3145x3173x3
0,37 - 0,450,55 - 0,751,1 - 1,5
2,23 - 45,57,5
9,2 - 1115
18,5223037455575
593
ConstructionSingle-phase mains supply control panel with frequency converter for 3pumps with three-phase 230V variable speed motor, for constantpressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor alternating the starting order at each start.
Technical data- Mains single-phase 230V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit.- EMC filter. - Frequency converter (1 for each pump).- MPS 4000 electronic card.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling.- Terminals board. - Terminals for remote signals- Pressure transducer - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 13M.- RA 100 control panel for remote alarm.
QML 3 VFT Control panel for 3 variable speeds pump with three-phase motor
Control panels
Code Type Max currentoutputmax A
Motor 230V - 3~
kW
Dimensions
HxBxP mm
ConstructionControl panel with frequency converter for 3 pumps with variable speedthree-phase motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor alternating the starting order at each start.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit.- EMC filter. - Frequency converter (1 for each pump).- MPS 4000 electronic card.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 13M.- RA 100 control panel for remote alarm.
QTL 3 VFT Control panel for 3 pumps with variable speed three-phase motor
Code Type Motor 400V - 3~
kW
Dimensions
HxBxP mm
Max currentoutputmax A
140594400001405945000014047640000140485100001405946000014048260000140472000001405164000014047300000140594700001405948000014048660000140594900001405950000014059510000140595200001405953000014059540000
QTL 1.2 VFT 0,45 - D 0,45QTL 1.2 VFT 0,75 - D 0,75QTL 1.2 VFT 1,5 - D 1,5QTL 1.2 VFT 2,2 - D 2,2QTL 1.2 VFT 4 - D 3QTL 1.2 VFT 4 - D 4QTL 1.2 VFT 5,5 - D 5,5QTL 1.2 VFT 7,5 - ST 7,5QTL 1.2 VFT 11 - ST 11QTL 1.2 VFT 15 - ST 15QTL 1.2 VFT 18,5 - ST18,5QTL 1.2 VFT 22 - ST 22QTL 1.2 VFT 30 - ST 30BQTL 1.2 VFT 30 - ST 30AQTL 1.2 VFT 37 - ST 37QTL 1.2 VFT 45 - ST 45QTL 1.2 VFT 55 - ST 55QTL 1.2 VFT 75 - ST 75
600x400x200600x400x200600x400x200600x400x200600x400x200600x400x200700x500x200800x600x250800x600x250800x600x250
1200x800x2501000x800x2501000x800x2501000x800x2501200x800x300
14059550000140595600001405957000014049710000140478400001405958000014059590000140596000001405961000014059620000140539400001405963000014059640000140596500001405966000014059670000
800x600x250800x600x250800x600x250900x600x250900x600x2501200x800x3001200x800x3001400x800x4001400x800x400
2000x1800x4002000x1800x400
2000x1800x4002000x1800x4002000x1800x4002000x1800x4002000x1800x400
1 - 1,61,6 - 2,52,5 - 44 - 6,54 - 6,56,3 - 109 - 1411 - 1716 - 2422 - 3130 - 3935 - 4342 - 5555 - 6561 - 8480 - 105100 - 125120 - 160
1,52,34,15,59,59,514,317
27,733
46,361,574,574,588106145173
1,5x42,3x44,1x45,5x49,5x414,3x417x4
27,7x433x4
46,3x461,5x474,5x488x4106x4145x4173x4
0,37- 0,450,55 - 0,751,1 - 1,5
2,23 - 45,57,5
9,2 - 1115
18,5223037455575
QTL 4 VFT 0,45QTL 4 VFT 0,75QTL 4 VFT 1,5QTL 4 VFT 2,2QTL 4 VFT 4QTL 4 VFT 5,5QTL 4 VFT 7,5QTL 4 VFT 11QTL 4 VFT 15QTL 4 VFT 18,5QTL 4 VFT 22QTL 4 VFT 30QTL 4 VFT 37QTL 4 VFT 45QTL 4 VFT 55QTL 4 VFT 75
0,37 - 0,450,55 - 0,751,1 - 1,5
2,234
5,57,5
9,2 - 1115
18,522303037455575
594
ConstructionControl panel with frequency converter for 3 pumps with three-phasemotor: one with variable speed motor (with frequency converter) and 2with fixed speed motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor alternating the starting order at each start.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - EMC filter. - Frequency converter. - Starting contactors of the second and third pump.- Timer (Y/Δ) from 7,5 kW. - Transformer.- MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 13M.- RA 100 control panel for remote alarm.
QTL 1.2 VFT Control panel for 1 variable speed pump and 2 fixed speed pumps
Control panels
Code Type Dimensions
HxBxP mm
ConstructionControl panel with frequency converter for 4 pumps with variable speedthree-phase motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor alternating the starting order at each start.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - EMC filter. - Frequency converter (1 for each pump).- MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 13M.- RA 100 control panel for remote alarm.
QTL 4 VFT Control panel for 4 pumps with variable speed three-phase motor
Code Type Motor 400V - 3~
kW
Dimensions
HxBxP mm
Max currentoutputmax A
Motor400V - 3~
kW
Max current output(Variable) (Fixed)max A max A
140596800001405718000014059690000140597000001405971000014059720000140597300001405974000014046890000140597500001405976000014059770000140597800001405979000014059800000140598100001405982000014059830000
QTL 1.3 VFT 0,45 - D 0,45QTL 1.3 VFT 0,75 - D 0,75QTL 1.3 VFT 1,5 - D 1,5QTL 1.3 VFT 2,2 - D 2,2QTL 1.3 VFT 4 - D 3QTL 1.3 VFT 4 - D 4QTL 1.3 VFT 5,5 - D 5,5QTL 1.3 VFT 7,5 - ST 7,5QTL 1.3 VFT 11 - ST 11QTL 1.3 VFT 15 - ST 15QTL 1.3 VFT 18,5 - ST 18,5QTL 1.3 VFT 22 - ST 22QTL 1.3 VFT 30 - ST 30BQTL 1.3 VFT 30 - ST 30AQTL 1.3 VFT 37 - ST 37QTL 1.3 VFT 45 - ST 45QTL 1.3 VFT 55 - ST 55QTL 1.3 VFT 75 - ST 75
700x500x250700x500x250700x500x250700x500x250700x500x250700x500x250700x500x2501100x700x2501100x700x2501100x700x2501200x800x3001200x800x3001200x800x3001200x800x3001600x800x4001700x800x400
1,52,34,15,59,59,514,317
27,733
46,361,574,574,588106145173
1 - 1,61,6 - 2,52,5 - 44 - 6,54 - 6,56,3 - 109 - 1411 - 1716 - 2422 - 3130 - 3935 - 4342 - 5555 - 6561 - 8480 - 105100 - 125120 - 160
0,37 - 0,450,55 - 0,751,1 - 1,5
2,234
5,57,5
9,2 - 1115
18,522303037455575
595
ConstructionControl panel with frequency converter for 4 pumps with three-phasemotor: one with variable speed motor (with frequency converter) and 3with fixed speed motor, for constant pressure booster sets.Arranged for SRL 3 level control application for probes connection againstdry-running. Pump operation controlled by an electronic board type MPS 4000 withmicroprocessor alternating the starting order at each start.
Technical data- Mains 400V ±10% 50 Hz (other voltages on request).- Ambient temperature from -5 °C to +40 °C.- Protection IP 44.
Components- Metal case. - Door lock master switch. - Fuses for power line. - Fuses for auxiliary circuit. - EMC filter. - Frequency converter.- Starting contactors of the second, third and fourth pump.- Timer (Y/Δ) from 7,5 kW. - Transformer. - MPS 4000 electronic board.- Interface for MPS 4000 electronic board.- Ventilator for electric panel cooling. - Pressure transducer - Terminals board. - Terminals for remote signals - Cable glands.
ON REQUEST:- SRL 3 level control for probes against dry running- Volt free contact module MSP 1M, control panel Q-MSP 13M.- RA 100 control panel for remote alarm.
QTL 1.3 VFT Control panel for 1 variable speed pump and 3 fixed speed pumps
Control panels
Code Type Motor400V - 3~
kW
Dimensions
HxBxP mm
Max current output(Variable) (Fixed)max A max A
top related