tanque contra incendio

TRANSCRIPT

  • REV 0

    1

    SERVICE M3 M3

    ERECTION SITE Bbl Bbl

    USER 1,00 AT 75,5 FT2600 MTS VAPOR PRESSURE 0,0435 psig 16,4 FT

    DESING WIND SPEED= 108 KMH INTERNAL PRESSURE DESIGN 0,90 IN H2o LIQUID TANK HEIGHT 15,1 FT

    C

    20 Jacks capacity 12.000 kg/und

    20 No Jacks required 30 und

    NOT No hydraulic unids 1 und EXTERNAL UND INTERNAL

    NOT TOTAL TOTAL137.022 lbs 62.283 KG 1.239 M2 1.367

    42.235 lbs 19.198 KG 361 M2 361

    1.032 LBS 469 KG 15 M2 15

    34.529 lbs 15.695 KG 416 M2 416

    47.118 lbs 21.417 KG 414 M2 416

    11.788 lbs 5.358 KG 12 M2 159

    319 LBS 145 KG 0 M2 0

    0 lbs 0 KG 21 M2 0

    0 lbs 0 KG 0 M2 0

    widths thicknesses widths thicknesses widths thicknesses

    1 72 in 0,25 4 in 0,00 7 in 02 72 in 0,25 5 in 0,00 8 in 03 72 in 0,25 6 in 0,00 9 in 0

    10 in 0

    0,25IN

    in3 3,02

    2,00%

    in3 16,29

    LAPBOLT QUANTITY 23 UND

    29,99 MINIMUN 24 INBOLT CIRCULE

    DIAMETER65,46 FTS Yes

    BOLT DIAMETER22,23 mm Not

    0,25IN BOLT MATERIAL

    SPECIFICATIONnot

    Conial 130 ft 0 LBS/FT2

    0,19 25 LBS/FT2

    ASTM A -36

    SHELL 0,0625 IN YES

    BOTTOM0,0625 IN 2A

    YES 0,15

    1

    1,5

    SHOP FIELD

    RADIOGRAFIA LIQ

    /PENETR

    ULTRASONID

    O

    SHELL BOTTOM

    A 283 Gr C

    A 283 Gr C

    ASTM A283 Gr C

    ASTM A283 Gr C

    ANCHOR SUPPORTS ,COLUMNS, ROOF STRUCTURS SUPPORT

    SHELL

    No SHELLS COURSES- PLATE WIDTHS AND THICKNESSES ( Including Corrosion Allowance)

    ROOF

    THICKNESS OF BOTTOM ANNULAR PLATES

    ROOF PLATES AND FRAMES

    MAX OPERATING TEMPERATURE

    STIFFENING RINGS

    AGUA

    PETAR SALITRE

    BOGOTA

    WELDING BOTTOM

    ASTM A36

    DESIGN SPECIFIC GRAVITY AT C

    WEIGHTMATERIAL SPECIFICATIONES

    LADDER,PLATFORMS, AND HANDRAILS

    INSULATION REQUIRED

    STANDARD 650 EDITION 11

    JACKS REQUIREMENTS TANK SPECIFICATIONS

    DESING METAL TEMPERATURE

    HEATER REQUIRED

    12.000 13.092

    TEMPERATURE

    ALTURA MSNM

    API STANDARD 650 DATE 25/02/2015STORAGE TANK BY G- Chaves

    2.0811.908

    FILE NoCONSTRUCTION DETAILS (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER

    MANUFACTURER

    DATA SHEET TANQUE AGUA CONTRA INCENDIO

    ASTM A-307

    El tanque es estructuralmente estable

    ASTM A36

    tank, need anchor bolt for wind

    PAINT AREAS

    BOTTOM + Anular Bottom plate+skind

    MAN HOLE AND NOZZLES ASTM A106 /A105

    ANCHOR BOLTS

    ROOF

    ROOF TO SHELL DETAILS

    PLATE THICKNESS

    ASTM A-307

    Intermedium Stiffening ring inercia Module

    upper Stiffening ring

    inercia Module

    SLOPE

    SELF SUPPORTED

    ANCHOR BOLTSTANK BOTTOM

    MINIMUM WIDTH ANNULAR PLATES

    INSPECTION PLACE

    ROOF TYPE Roof diameter

    IMPORTANCE FACTOR

    THICKNESS OF ROOF PLATES

    ZONE FACTOR(TABLE E2 )

    SITE COEFFICIENTE ( TABLE E-3)

    DEAD LOADS OVER ROOF

    CORROSION ALLOWANCE

    FOUNDATION TYPE

    ROOF LOADS

    WELD EXAMINATION

    INSPECTIONS

    EARTHQUAKE DESIGN

    SISMIC ZONE

    El tanque es estructuralmente estable

    OTHERS

    APENDIX E DESIGN

    CONCRETE RING WALL WITH ANCHOR BOLTS

    CONCRETE RING WALL

    EARTH

    SHELL TOTAL HEIGHT

    NOMINAL CAPACITY LIQUID NET MAXIMUN CAPACITY TANK

    SUPPORTED

    LIVE LOADS OVER ROOF

    intermedium stiffening ring Not required

    INTERNAL DIAMETER

    FLOTING SEAL

    in