datasheet orc eno-100ltenogia.com/docs/datasheets/100lt-2019-en.pdf · 2020. 7. 15. · orc...
Post on 15-Mar-2021
1 Views
Preview:
TRANSCRIPT
“ Generate power from your waste heat thanks to our ORC “
DATASHEET
ORC ENO-100LTORC ENO-100LT
Founded in 2009, ENOGIA is a turbine based ORC manufacturer specialised in waste heat recovery with systems producing from 10 kWe to 180 kWe.
The ENO-100LT module is an ORC manufactured by ENOGIA, able to recover up to 1400 kWth and having a nominal power output of 100 kWe from low temperature heat sources.
High speedpatented micro-turbines
Hydraulic connections with standard fl anges
Assembling and performance testingin ENOGIA workshop
Remote control and access24/7
Plug-and-play system on a single skid
THE PRODUCTTHE PRODUCT
SYSTEM COMBINING PERFORMANCE SYSTEM COMBINING PERFORMANCE AND RELIABILITY AT LOW TEMPERATUREAND RELIABILITY AT LOW TEMPERATUREDesigned with the same state of mind as the other ORC of the LT range, the ENO-100LT is a turnkey product raising from architectural innovations.
This system suits a wide range of heat recovery applications such as biomass boilers, gas engines, geo- thermal sources, heating processes or concentrating solar panels. Any heat fl ow with temperatures between 70°C
and 120°C can be recovered with this system thanks to its two kinetic turbines.
The produced electricity is monitored by decoupling protection relays, ensuring its compliance with the grid.Remaining heat can be recovered for fl oor heating or drying system to reach a global effi ciency close to 95% !
TECHNICAL DATA
ENO-100LT CHARACTERISTICSENO-100LT CHARACTERISTICS
DIMENSIONSDIMENSIONS
Electrical ratings Maximum gross electric power Grid connection
100 kWe400V, 3ph, 50-60 Hz
Heat source
Temperature range Thermal power input rangeHot source mediumHydraulic connections
70-120°C800-1400 kWthWaterDN 150, PN 16
Cold source
Temperature rangeWorking fl uidCooling systemHydraulic connections
0-60°CWaterDry cooler, cooling towerDN 150, PN 16
Main components
Working fl uid Generator ExpanderHeat exchangers PumpControlsMonitoring
R1233zdMedium speed, permanent magnet Kinetic turbineBrazed plate Multi-stage magnetic couplingIndustrial PLCRemote web support
Main ratings
WeightDimensions L x w x h EnvironmentalNoise level @10mDesign lifetime Safety
3000 kg2,0m x 1,7m x 2,0mIP 2060 dB20 yrsNon fl ammable, non toxic, ODP=0
Norm compliance
Machine directive PEDElectrical norms Grid codes
2006/42/EG2014/68/EU2014/35/EGVDE-0126 (G59, VDE-ARN, UL,...)
ENOGIA - 19 avenue Paul Héroult 13015 MARSEILLE+33(0)4.84.25.60.17 / info@enogia.comwww.enogia.com
ENOGIA @enogia_orc Enogia ORC
This equipment should be installed as close as possible to the heat source to reduce heat losses through the pipes.