datasheet system conquest 6_17.12.11_01
Post on 21-Jan-2016
40 Views
Preview:
DESCRIPTION
TRANSCRIPT
Datasheet System Conquest 6_17.12.11_01 1/9
CONQUEST 6
Electronic control systemfor whirlpool
Product datasheet
VALANTIS SARLCH – 2610 ST-IMIER
2/9
Features
ON/OFF blower
ON/OFF pump
Manual blower power control (+/-)
Variation of blower flow (wave effect)
Interval pump Water level control
Spot light or RGB light (chromotherapy)
Concept
Disinfection mode (drying)
Safety rules
IMPORTANTFollow the directions for installation and connection of the control box. This one is not suitable for
medical use.
a) The box must be located in a dry and clean area with good ventilation and installed at least 3 centimers above the ground floor.b) Make sure that there are no unconnected wires inside the control box.c) Keep at least 2 centimeters between low and high power cables.d) All electrical parts must be mounted in a such way that they cannot fall down into the whirlpool.e) It is highly recommended to contact a state-registered electrician for installation. Valantis declines all responsability for consequences of damages caused by the device.f) Temperature ranges : storage -20 to 60°C, operating 0 to 45°C.g) It is not recommended to put on stress the system over an normal use. A security stops it automatically if any activity is detected after 20 minutes.h) On the main entry of the electrical installation, a fuse (FI) corresponding at least to the sum of the power supply of the device must be installed
We reserve the right to change the product and specification without notice. VALANTIS SARL
CH – 2610 ST-IMIER
Water level ControllerNewjac 8
Blower
Spot Chromo 1
Panel Conquest 6
Driver Chromo 2 Spot Chromo
2
Pump
Spot
Interval blower Rincing mode (flush)
Rincing valve or chemical disinfection
Datasheet System Conquest 6_17.12.11_01
Water heater
Water heater
Chemical Disinfection
3/9
Components
Plastic enclosure 45x30x15mm1 LED indicatorAdjustable by trimmerCable length 1800 mm. IP65ROHS
Water level sensor « TLS1 »Code 0010137600
VALANTIS SARLCH – 2610 ST-IMIER
Panel Conquest 6Code VPF09026X1
Non-contractual picture
Non-contractual picture
Datasheet System Conquest 6_17.12.11_01
Oblong shape plastic enclosure 174 x 30 mmChrome coated enclosure.Membrane foil front panel6 buttons 2 LED’s indicatorCable length 2000 mm.IP65 / ROHS
Controller Newjac 8Code VPF07002C1
Control box 230V 50/60 Hz 16A2 variable outputs (triacs)3 ON/OFF outputs (relays)Plastic enclosure 200x155x80 mmFit out with- 4 cable glands PE M16 for cable 5-10 mm.- 3 grommets (shutters) M16IP56ROHS
Non-contractual picture
4/9
Components 2/2
Driver Chromo 2Code VPF10030A1
Plastic enclosure 130 x 90 x 55 mm2 inputs for RGB spot lightFit out with :- 1 x PE M16 for cable diam. 5-10 mm- 1 x grommet (shutters) M16- IP56 / ROHS
VALANTIS SARLCH – 2610 ST-IMIER
Spot ChromoCode VPF10031A1
Chrome coated enclosure diam. 55 mmThickness 1.5 mm8 colours (white, red, orange, yellow,green, blue, indigo, purple)Cable length 2000 mm. with PE M16 + nutIP65 / ROHS
Non-contractual picture
Non-contractual picture
Datasheet System Conquest 6_17.12.11_01
5/9
Control box connection
Specification
Rated voltage :230V, 50/60Hz, 1 phaseRated power : 3680WRated current :16A
Maximum load
Water heater: 230V, 9A, 2070WSpot : 230V, 9A, 2070WRincing valveor chemical disinfection: 230V, 9A, 2070WPump : 230V, 6A, 1380WBlower : 230V, 6A, 1380W
The sum of the loads must not exceed rated power and current
VALANTIS SARLCH – 2610 ST-IMIERDatasheet System Conquest 6_17.12.11_01
PowerSupply230V
Panel Conquest 6Code VPF08012X15V
Water level sensor TLS1Code 00101376005V
Spot230V
Pump230V
+ = whiteSD = brown- = green
+
-SD
Rincing valve230VorChemical disinfection230V
WaterHeater230V
Blower230V
6/9
Recommended connection with RGB spot light
VALANTIS SARLCH – 2610 ST-IMIER
IMPORTANT : 5V cables (panel, temperature and water level sensor) must notcross power areas of the electronic board. Outside the enclosure, it is highlyrecommended to separate cabling of 230V and 5V cables.
Datasheet System Conquest 6_17.12.11_01
1. ON/OFF spot or RGB spot light2. ON/OFF pump / Interval pump/ Water heater / Disinfection (option)3. Variation blower / Interval blower4. ON/OFF blower5. + blower 6. - blower 7. LED pump8. LED blower
VALANTIS SARLCH – 2610 ST-IMIER
FUNCTION BUTTON ACTION ON BUTTON
RESULT OF ACTION ON BUTTON / STATE LED INDICATOR
Switch on the system."Waiting for water" mode enable (not enough water in the whirlpool.) Panel disable for use.
LED 8 blinks each 5 sec.
Enough water in the whirlpool. Ready for bath. Panel enable for use.
LED 7 and 8 ON
1st press Blower ON. Power flow 100%. LED 8 blinks 2 x per sec.
2nd press Blower OFF. LED 8 ON
Press Blower ON. Power flow 100%. Available for +/- LED 8 blinks 2 x per sec.
1st continued press
Decrease power of blower LED 8 blinks 2 x per sec.
2nd continued press
Increase power of blower LED 8 blinks 2 x per sec.
Press Blower OFF LED 8 ON
Press Blower ON. Power flow 100%. Available for Variation / Interval
LED 8 blinks 2 x per sec.
Press Start Variation program LED 8 blinks 2 x per sec.
Press Switch from Variation to Interval mode and so on at each next action on button
LED 8 blinks 2 x per sec.
Press Blower OFF LED 8 ON
1st press Pump ON. Power flow 100%. Water heater ON (if connected)
LED 7 blinks 2 x per sec.
2nd press Pump OFF. Water heater OFF. LED 7 ON
Press Pump ON. Power flow 100%. LED 7 blinks 2 x per sec.
Press (long 2 sec.)
Start interval. Water heater OFF (if connected) LED 7 blinks 2 x per sec.
Press Pump OFF LED 7 ON
INTERVAL WATER
AIR - / +
VARIATION / INTERVAL AIR
AIR
WATER
1 2 3 4 5
7
6
8
User manual 1/2
Datasheet System Conquest 6_17.12.11_01 7/9
VALANTIS SARLCH – 2610 ST-IMIER
FUNCTION BUTTON ACTION ON BUTTON
RESULT OF ACTION ON BUTTON / STATE LED INDICATOR
CHEMICAL DISINFECTION (OPTION)
Press (long 2 sec.)
Pump + Disinfection valve ON After 5 sec. Disinfection valve OFF After 3 min. Pump OFF. During the cycle, button 2 allows to stop the process. Other functions are not available.
LED 7 blinks 2 x per sec.
1st press Start Spot light or Chromotherapy light program
2nd press Stop Spot light or Chromotherapy light program
1st press Start chromotherapy light program
Double click Fix on current colour
Next double click Fix on next colour
2nd press Stop RGB light
All the functions are automatically stopped after 20 min. of inactivity
LED 7 and 8 ON
This function is enable only if the water level sensor has detected water during at least 2 min.Whirlpool is emptying. No detection of water during 12 min. (continually) = Disinfection mode enable.
LED 7 and 8 blink each sec.
After 12 min, Blower ON during 3 min. LED 8 blinks each sec.Blower OFF. Return to "Waiting for water" mode LED 8 blinks each 5
sec.During this cyle button 4 is enable to stop drying modeThis function is enable only if the water level sensor has detected water during at least 2 min.Whirlpool is emptying. No detection of water during 8 min. (continually) = Disinfection mode enable.
LED 7 and 8 blink each sec.
After 8 min, Rincing valve ON during 1 min. LED 7 blinks each sec.Then waiting time during 3 min. LED 7 and 8 blink each
sec.Finally Blower ON during 3 min. LED 8 blinks each sec.Blower OFF. Return to "Waiting for water" mode LED 8 blinks each 5
sec.During this cyle button 4 is enable to stop disinfection mode
DISINFECTION OPTION NR. 2 : RINCING+DRYING
DISINFECTION, OPTION NR. 1 : DRYING
RGB LIGHT (MANUAL)
SPOT LIGHT OR RGB LIGHT (AUTOMATIC)
User manual 2/2
Datasheet System Conquest 6_17.12.11_01 8/9
VALANTIS SARLCH – 2610 ST-IMIER
Programs
The panel contains several programs whose can be selected by a code.The following programs are available :
Program
Nr. Description
ST6A 1 Panel Conquest 6A without disinfection
ST6AT 2 Panel Conquest 6A with progressive drying disinfection
ST6E 3 Panel Conquest 6E without disinfection
ST6R 4 Panel Conquest 6E with rincing disinfection
ST 5 Panel Conquest 6 without disinfection
STAT 6 Panel Conquest 6 with progressive drying disinfection
STET * 7 Panel Conquest 6 with rincing + progressive drying desinfection
TST 8 Test (Valantis internal use only)
Re-programming instructions :
Switch on the system with water into the whirlpool.Within 2 min., drain the whirlpool until the TLS don’t detect water anymore (LEDs blink each 5 sec.).Press buttons 0 1 2 0 1 during an interval of maximum 2 min. LEDs blink 8 times per sequence.Button 0 = select program. Observe corresponding LED sequence blinking as per a.m. program nr.Button 1 = save selected program.Button 2 = cancel the selection. Return to the previous program.
* Ex-factory setting
Datasheet System Conquest 6_17.12.11_01
012
9/9
top related