diving safty & decompression meter
Post on 14-Jan-2015
233 Views
Preview:
DESCRIPTION
TRANSCRIPT
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12 1
2
Diving Safty and Decompression Meter ((Dive Computer, Decompression Computer
Dr.A.EBADI.AEROSPACE & DIVING MEDICINE,ARMY UNIVERSITY OF MEDICAL SCIENCE. 12/27/دسامبر gasabeh.com gasabeh47@gmail.com
3
INTRODUCTION
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
4
-Professional Association of Diving Instructors (PADI)
-National Association of Underwater
(NAUI)Instructors
(BSAC)Aqua Club -British Sub- -Confederation Mondiale des Activites
(CMAS) Subaquatiques
CERTIFICATES
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12 5
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12 6
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12 7
8 2000-2006-Diving Alert Network(DAN) 12/27/دسامبر gasabeh.com gasabeh47@gmail.com
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12 9
10
DISCUSSION
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
11
A:Decompression Sickness (DCS) History:
and compressed air workers diversDCS recognized in -since late 1800s
was to ascend slowly guidelinePrevailing -
ft/min5 ft/min to 1.5 Standards ranged from
less frequentlyDCS still occurred but -
nitrogen bubblesDCS associated with -
: Shorter/shallower dives associated with less Haldane-frequent/less severe DCS
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
12
Decompression Theory nitrogen at depth tissues absorbs Body -
absorbs nitrogen at different ratetissue type Each -
releases nitrogen Slow, staged ascent (“decompression”) -and is exhaled Stages determined by time/depth of harmlessly
each dive
nitrogen bubble decompression causes without adequate Ascent -formation
= “Decompression Sickness” manifestationsClinical
)obstructiveDestructive,compressive,(
6 % within 95-after dive minutes to hoursTypically presents -hours
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
13
Type I DCS Musculoskeletal pain (Limb bends)-
manifestation of DCSMost common
, not well localized; no change with Dull painmovement
, elbows, or shoulders most commonly Kneesinvolved
DCS (Skin bends) Cutaneous-
Pruritis and erythema of trunk
Treatment: Recompression-
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
14
Type II DCS
Risk of permanent disability or death-
Pulmonary DCS (“Chokes”)- clog pulmonary arterial gas emboli Venous -
circulation
from deep diverapid ascent Rare; occurs with -
discomfort, cough; worse with deep Substernal- inspiration
and sided heart failure -rightMay lead to - collapsecardiovascular
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
15
)con’tType II DCS (
Neurologic DCS spinal cordPredilection for -
deep divesRecreational divers doing short, -
after ascentminutes to hours over –Syndrome -
-Tingling in trunk
-Progressive numbness and paresthesias
-Ascending motor weakness
-Bowel/bladder incontinence
-Severe cases may present with LOC/paraplegia
-Cerebral manifestations: memory impairment, aphasias, visual disturbances, personality changes
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
16
)con’tType II DCS ( Vestibular DCS (“Staggers”)
, nausea, vomiting, dizzinessSudden onset of - hearing loss and tinnitus -, +/nystagmus
in recreational diversNot common -
barotraumaConfused with middle ear -
Treatment of Type II DCS: with hyperbaric oxygen recompressionRapid -
Supportive care: Fluids
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12 17
18
SCUBA DIVING SAFTY(most common)
Medical
Planning
Equipmental
Environmental
Decompression Meter (Dive Computer)B:
(Self Contained Under-water Breathing Apparatus)
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
19
are used for planning dives to dive tables Traditionally -avoid risk of DCI
of depth and timesafety limits Dive tables contain -
-There are many standard dive tables, Original UK, US Navy etc.
many (an algorithm Dive tables can be generated by -variations possible)
run these algorithms(Different Dive computers -Algorithm*)
Dive Tables
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
20
Dive Tables
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
21
Decompression Meter (Dive Computer)
Wrist Dive Computer Console Dive Computer 12/27/دسامبر gasabeh.com gasabeh47@gmail.com
22
Decompression Meter (Dive Computer)
Manufacturers -Citizen -Liquivision -Seiko -Suunto -Uemis -VR Technology -Underwater Technology Center
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
23
• Sensors send data to the Analog to Digital (A/D) Converter.
• A/D Converter changes analog data to digital signals.
• The Micro Processor calculates the data and presents it to the diver via the LCD Display.
Decompression Meter (Dive Computer)
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
gasabeh.com gasabeh47@gmail.com 24
Depth-Time Profile
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
00'20"
01'40"
03'00"
04'20"
05'40"
07'00"
08'20"
09'40"
11'00"
12'20"
13'40"
15'00"
16'20"
17'40"
19'00"
20'20"
21'40"
23'00"
24'20"
25'40"
27'00"
28'20"
29'40"
31'00"
32'20"
33'40"
35'00"
36'20"
37'40"
39'00"
40'20"
41'40"
43'00"
44'20"
45'40"
47'00"
Time
Dep
th
Bottom Time
Bottom Zone
Surface
A
A
MaximumDepth
0.85% MaximumDepth
min 12.0of bottom timeRisky dive with some minor problems. Because your exceeds no-stop limit by 4.0min this dive is risky. But you performed the ascent
was poor as indicated by ‘saw bottom zonewell. Your buoyancy control in the time profile.-’ on the depthAtooth’ patterns marked ‘
27/دسامبر/12
25
of gas uptake and release, such as the Mechanical models -1s)1960-through restricted orifices.(SOSmovement of gas
Suuntoof the established decompression tables( Electronic models -2
diving unilevel-USN meter.)
using the decompression theories on which Electronic models -3level diving-multi-)Nx100 different tables.(VEO
Decompression Meter (Dive Computer)
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
26
COMPUTERS vs. TABLES
*UNI LEVEL DIVING 12/27/دسامبر gasabeh.com gasabeh47@gmail.com
27
COMPUTERS vs. TABLES
MULTI LEVEL DIVING 12/27/دسامبر gasabeh.com gasabeh47@gmail.com
28
dives* Unsafe in dive profiles are known patternsThe following
to cause DCI
(Detect)ascentRapid -
Sawtooth-
dive profile etc. Reverse-
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
29
Rapid Ascent -A pattern in the dive profile caused by the diver
to the surfacerising rapidly
causing critical factor Rapid ascent is the most -bubbles in body tissues
of causing DCIhigher chance Therefore has -
detect rapid Most dive computer software -ascents and sound alarms
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
30
Sawtooth -A pattern in the dive profile caused by the diver
in quick successiondown and up going
-This may not happen very frequently, but when it happens it may cause the tissues to absorb excess gas bubbles
cause DCITherefore may -
does not detect themDive computer software - gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
31
Reverse Profile -This is a pattern observed at the level of a
.whole dive profile
-Ideally a diver is required to initially reach the and then all the planned maximum depth
subsequent dive should be performed at a depth shallower than the maximum
-A reverse profile is a dive profile where the reverse of the idealdiver performs the
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
32
*CharactristicsPersonal
1- Age 2- Sex
3-BMI-(Fatty Tissue Percent)
4-Health State (DM-HLP-Nutrition-Metabolism)
5-Body Position & Activity
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
33
CONCLUSIONS
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
34
از کننده استفاده غواصان صعود زمان کاهش به توجه با
DECOMPRESSION COMPUTERS احتمال افزایش وبنابراین
Hyperbaric Chamber به ونیاز DCS بالینی عالیم بروز
: شود می توصیه
فشار برداشت جداول همراه وبه کمکی صورت به غواصان -1
را موضوع این نمایندو استفاده ها دستگاه این از استاندارد
.دهند قرار نظر مد متر 30 از بیش های غوص در بخصوص
منظورکنترل به بایست می ها دستگاه ازاین استفاده درصورت -2
احتمالی برداشت بیماری عالیم وبهبود Hyperbaric فشار Chamber حاضرباشد غوص درمحل.
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
35
گرینویچ ساعت براساس زمان کردن استاندارد همانند -4
وبا المللی بین قبول قابل مبدا یک اساس بر استاندارد غوص،
مطرح، غواصان فشاربرای برداشت بیماری ریسک حداقل
قرارگرفته جهانی تایید مورد مرتبط های سازمان وازسوی براساس DECOMPRESSION COMPUTERS مختلف وانواع
.گردد تنظیم آن
ایمنی ارتقائ درجهت زمینه دراین بیشتر تحقیقات انجام لزوم -5 DECOMPRESSION COMPUTERS با غواصی
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
36
SAFETY GUIDELINES the Dive Computer(instruction/ Authorized understand how to use Fully -1
Oceanic Dealer )
presented in the Operating function varies from the information Any display or -2Manual (Authorized Oceanic Dealer )
condition (do not dive until the battery is replaced)Low battery -3
(Dive Computer must be verified, or set)dive NitroxEach -4
(if available) in normal zones throughout your dives.bar graphs The -5
deepest dive firstAlways make your -6
and experiencethe level of your training Always limit your dive to -7
between each diveadequate surface interval Allow an -8 12/27/دسامبر gasabeh.com gasabeh47@gmail.com
37
SAFETY GUIDELINES
M)(greatly 39 (FT 130 deeper than Decompression diving, or diving -9increase your risk of decompression sickness
10-Decompression diving is inherently hazardous and greatly increases , even when performed according your risk of decompression sickness
to the Dive Computer’s calculations.
of no guarantee Using a Dive Computer, just as dive tables, is -11avoiding decompression sickness
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
38
Refrences 1- Petar J. Denoble, MD., D.Sc Alessandro Marroni, MD. D.S Richard D. Vann, Ph.D.Common Factors in Diving Fatalities Fatality Workshop, Durham April 8-10, 2010
2-www. DivingCaribbeanNicheMarkets.
3-www. Wikipedia, the free encyclopedia- Dive computer
4- Carl Edmonds M.B., B.S. (Sydney), Christopher Lowry M.B., B.S., John Pennefather B.SC. Robyn Walker M.B., B.S., Dip. D.H.M. Diving and Subaquatic Medicine 4th Edition 2002
5-Wilmshurst peter.Technological advances in scuba diving do not always increase safety.Bjsm.bmj.com.2011
. gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
39
THANKS FOR YOUR
ATTENTION
gasabeh.com gasabeh47@gmail.com 27/دسامبر/12
top related