dm1 250m6 37,0kw
Post on 18-Oct-2015
10 Views
Preview:
TRANSCRIPT
-
Dutchi Motors B.V. DM1- 250 M6 IM B3 / IM 1001
Power is our commodity, the world is our market !
Specification IEC 60034-1 Efficiency classManufacturer Dutchi Motors B.V. Load data 100% 75% 50% 25%Motor type DM1- Efficiency 91,6 91,7 90,7 85,8 %Rated power 37 kW S1 duty Power factor 0,88 0,85 0,78 0,59Speed 980 r.p.mVoltage 400 / 690 V Sound pressure level (1m) 63,9 dB(A)Frequency 50 Hz Resistance R20 (open) 0,211 Connection / Y Resistance R20 0,140 Amps full load 66,0 / 38,1 AAmps no-load(400V) 21,80 A Full load torque 360,56 NmEnclosure IP 55 DOL Starting torque vs FL torque 1,94Insulation Class F (temp. rise B (80 K)) DOL Pull up torque vs FL torque 1,47
DOL Pull out torque vs FL torque 3,09Max. coolant temp. 40C Star-Delta Starting torque vs FL torque 0,61Max. altitude 1.000 mtr, above sea level Star-Delta Pull up torque vs FL torque 0,46Comment 3 x PTC 150C Star-Delta Pull out torque vs FL torque 0,96Cable entries 2 x M63x1,5 + 1 x M20x1,5 (ptc) DOL Starting current vs FL current 6,88
Star Delta Starting current vs FL current 2,15Feature Cast-iron motor Rotor Inertia 0,8070 kgm2Weight 408 kgCatalog no. Bearing DE 6314 - ZZ C3Warranty 12~18 months Bearing NDE 6314 - ZZ C3
WI date sign.
date sign.
Drawing made by : 27-04-04 HvD
Power is our commodity, the world is our market !
P.O. Box 5390
N/A
www.dutchi.comdutchi.motors@dutchi.nl
Fax : +31-(0)26 - 3541 650Tel : +31-(0)26 - 3541 600
NL-6802 EJ ARNHEM
Dutchi Motors B.V.
Change
Discription
250 M6
11136A37D
HvD
2/00
DM1-250M4~8 B3DUTCHI MOTORS B.V.
252
12 -06-01
216
168 349
445
485
125
140
98
406484
30
617
80
116
2 50
65
m6
910
24
DM1- 250 M4-6-8.xls - IM B3 We make all efforts to better our products. Versions, technical data and figures could be changed therefore. They are not binding before written confirmation. 29-5-2006 21:44
-
Dutchi Motors B.V. DM1- 250 M6 IM B35 / IM 2001
Specification IEC 60034-1 Efficiency classManufacturer Dutchi Motors B.V. Load data 100% 75% 50% 25%Motor type DM1- Efficiency 91,6 91,7 90,7 85,8 %Rated power 37 kW S1 duty Power factor 0,88 0,85 0,78 0,59Speed 980 r.p.mVoltage 400 / 690 V Sound pressure level (1m) 63,9 dB(A)Frequency 50 Hz Resistance R20 (open) 0,211 Connection / Y Resistance R20 0,140 Amps full load 66,0 / 38,1 AAmps no-load(400V) 21,80 A Full load torque 360,56 NmEnclosure IP 55 DOL Starting torque vs FL torque 1,94Insulation Class F (temp. rise B (80 K)) DOL Pull up torque vs FL torque 1,47
DOL Pull out torque vs FL torque 3,09Max. coolant temp. 40C Star-Delta Starting torque vs FL torque 0,61Max. altitude 1.000 mtr, above sea level Star-Delta Pull up torque vs FL torque 0,46Comment 3 x PTC 150C Star-Delta Pull out torque vs FL torque 0,96Cable entries 2 x M63x1,5 + 1 x M20x1,5 (ptc) DOL Starting current vs FL current 6,88
Star Delta Starting current vs FL current 2,15Feature Cast-iron motor Rotor Inertia 0,8070 kgm2Weight 408 kgCatalog no. Bearing DE 6314 - ZZ C3Warranty 12~18 months Bearing NDE 6314 - ZZ C3
WI date sign.
date sign.
Drawing made by : 27-04-04 HvD
Discription
Change
250 M6
Power is our commodity, the world is our market !
P.O. Box 5390
www.dutchi.comdutchi.motors@dutchi.nl
Fax : +31-(0)26 - 3541 650Tel : +31-(0)26 - 3541 600
N/A
NL-6802 EJ ARNHEM
Dutchi Motors B.V.
11536A37D
HvD
2/00
DM1-250M4~8 B35DUTCHI MOTORS B.V.
12-06-01
252216
168 349
445
485
125
910
98
60
m6
450
550
140
30
617
250
500
19
484406
2480
DM1- 250 M4-6-8.xls - IM B35 We make all efforts to better our products. Versions, technical data and figures could be changed therefore. They are not binding before written confirmation. 29-5-2006 21:44
-
Dutchi Motors B.V. DM1- 250 M6 IM B5 / IM 3001
Specification IEC 60034-1 Efficiency classManufacturer Dutchi Motors B.V. Load data 100% 75% 50% 25%Motor type DM1- Efficiency 91,6 91,7 90,7 85,8 %Rated power 37 kW S1 duty Power factor 0,88 0,85 0,78 0,59Speed 980 r.p.mVoltage 400 / 690 V Sound pressure level (1m) 63,9 dB(A)Frequency 50 Hz Resistance R20 (open) 0,211 Connection / Y Resistance R20 0,140 Amps full load 66,0 / 38,1 AAmps no-load(400V) 21,80 A Full load torque 360,56 NmEnclosure IP 55 DOL Starting torque vs FL torque 1,94Insulation Class F (temp. rise B (80 K)) DOL Pull up torque vs FL torque 1,47
DOL Pull out torque vs FL torque 3,09Max. coolant temp. 40C Star-Delta Starting torque vs FL torque 0,61Max. altitude 1.000 mtr, above sea level Star-Delta Pull up torque vs FL torque 0,46Comment 3 x PTC 150C Star-Delta Pull out torque vs FL torque 0,96Cable entries 2 x M63x1,5 + 1 x M20x1,5 (ptc) DOL Starting current vs FL current 6,88
Star Delta Starting current vs FL current 2,15Feature Cast-iron motor Rotor Inertia 0,8070 kgm2Weight 408 kgCatalog no. Bearing DE 6314 - ZZ C3Warranty 12~18 months Bearing NDE 6314 - ZZ C3
WI date sign.
date sign.
Drawing made by : 27-04-04 HvD
250 M6
Change
Discription
Power is our commodity, the world is our market !
P.O. Box 5390
www.dutchi.comdutchi.motors@dutchi.nl
11236A37D
Fax : +31-(0)26 - 3541 650Tel : +31-(0)26 - 3541 600
N/A
NL-6802 EJ ARNHEM
Dutchi Motors B.V.
12 -06-01HvD
2/00
DM1-250M4~8 B5DUTCHI MOTORS B.V.
216
485
125
910
98
450
550
65
m6
367
140
252
500
19
DM1- 250 M4-6-8.xls - IM B5 We make all efforts to better our products. Versions, technical data and figures could be changed therefore. They are not binding before written confirmation. 29-5-2006 21:44
-
Dutchi Motors B.V. DM1- 250 M6 IM V1 / IM 3011
Specification IEC 60034-1 Efficiency classManufacturer Dutchi Motors B.V. Load data 100% 75% 50% 25%Motor type DM1- Efficiency 91,6 91,7 90,7 85,8 %Rated power 37 kW S1 duty Power factor 0,88 0,85 0,78 0,59Speed 980 r.p.mVoltage 400 / 690 V Sound pressure level (1m) 63,9 dB(A)Frequency 50 Hz Resistance R20 (open) 0,211 Connection / Y Resistance R20 0,140 Amps full load 66,0 / 38,1 AAmps no-load(400V) 21,80 A Full load torque 360,56 NmEnclosure IP 55 DOL Starting torque vs FL torque 1,94Insulation Class F (temp. rise B (80 K)) DOL Pull up torque vs FL torque 1,47
DOL Pull out torque vs FL torque 3,09Max. coolant temp. 40C Star-Delta Starting torque vs FL torque 0,61Max. altitude 1.000 mtr, above sea level Star-Delta Pull up torque vs FL torque 0,46Comment 3 x PTC 150C Star-Delta Pull out torque vs FL torque 0,96Cable entries 2 x M63x1,5 + 1 x M20x1,5 (ptc) DOL Starting current vs FL current 6,88
Star Delta Starting current vs FL current 2,15Feature Cast-iron motor Rotor Inertia 0,8070 kgm2Weight 408 kgCatalog no. Bearing DE 6314 - ZZ C3Warranty 12~18 months Bearing NDE 6314 - ZZ C3
WI date sign.
date sign.
Drawing made by : 27-04-04 HvD
Power is our commodity, the world is our market !
P.O. Box 5390
N/A
www.dutchi.comdutchi.motors@dutchi.nl
Fax : +31-(0)26 - 3541 650Tel : +31-(0)26 - 3541 600
NL-6802 EJ ARNHEM
Dutchi Motors B.V.
Change
Discription
250 M6
11036A37D
HvD
2/00
DM1-250M4~8 V1DUTCHI MOTORS B.V.
12-06-01
252
216
48512
5
910
98
450
550
65m6
83
140
367
500
19
993
690
DM1- 250 M4-6-8.xls - IM V1 We make all efforts to better our products. Versions, technical data and figures could be changed therefore. They are not binding before written confirmation. 29-5-2006 21:44
top related