dr. arnd schmücker, peter schwengler tgls, pipelines competence centre paris 12. september 2007

Post on 30-Jan-2016

66 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

GAS CAMERA Mobile imaging system to detect methane plumes from distances between 0 m and at least 100 m. Dr. Arnd Schmücker, Peter Schwengler TGLS, Pipelines Competence Centre Paris 12. September 2007. Overview. Project Goal Development Status Next Steps. 1. Project Goals. Vision: - PowerPoint PPT Presentation

TRANSCRIPT

GAS CAMERA

Mobile imaging system to detectmethane plumes from distancesbetween 0 m and at least 100 m

Dr. Arnd Schmücker, Peter Schwengler

TGLS, Pipelines Competence Centre

Paris 12. September 2007

Page 2

Project Goal

Development

Status

1. Next Steps

Overview

Page 3

1. Project GoalsVision:Mobile imaging system to detectmethane plumes from distancesbetween 0 m and at least 100 m

Main Demands: Removable Low energy consumtion High measure responsivity Real time visualisation Easy handling All-purpose

Page 4

1. Project Goal: „Gas Camera“ Specification

Specification Overall RequirementsTarget gas Methane CH4Max. weight 25 kgDetection range 100 ppm mLeakage rate < 100 L/h (25 L/h under ideal conditions)Locality Pipelines and stations, open and closed; explosion

proofVisualisation Overlay of results with real video imageSpatial resolution min. 128 x 128 pixelService staff Work men with special trainingWeather condition All weather conditions ; -20°C up to 40°C Field of regard 100 m x 20 mFrame rate > 1/sEnergy Battery; min. 4 hours autonomic; < 100 W

(including computer)Max. dimensions 0,5 m x 0,3 m x 0,25 m

Page 5

2. Development Basis : IR-Spektroskopie• Spectrometer

• Scanner

• Video System

• PC Control Unit

Page 6

2. Development Basis: Interference Filter Principle

700 800 900 1000 1100 1200 1300 14000

0.2

0.4

0.6

0.8

Wavenumber (cm-1)

Filt

er T

rans

mis

sion

/Abs

orba

nce

Filter 1(Target Gas)

Filter 2(Reference)

Page 7

Calibration Unit

Filter Wheel

IR Lens

Detector Array

2. Development: Principe and Prototype

Page 8

3. Hardware-Status: Detector-Array

Frame GrabbersVideoCamera

• Full functionality implemented in

prototype system

Page 9

3. Software-Status

Video Image

Gas Imageoverlay

Control

Page 10

Measurement of Methane

Air temperature : 15.1 oCWall temperature : 18.3 oCDistance : 6 mRelease rate : 340 L/h

3. Measurements

Page 11

Measurement of Methane

Air temperature : 17.2 oCWall temperature : 21.2 oCDistance : 14 mRelease rate : 34 L/h

3. Measurements

Page 12

4. Status and Next Steps Automatic calibration unit Gigabit ethernet “Frame Grabbers” implementation System control via ethernet Control-Electronic development Video image background and gas image overlay Control and anlysis software development Basic-Detector-Array development Detector-Array implementation Market study Milestone I (Prototype finished): October 2007 Field trials under real conditions