e124 - global access...2 + + dl1 sw7 j12 j4 m1a j14 j13 j15 j3 j5 j6 j7 j8 j9 j10 j11 j2 j1 m1a dl20...
Post on 01-Apr-2020
9 Views
Preview:
TRANSCRIPT
E124
1
EN
GL
ISH
CE DECLARATION OF CONFORMITYManufacturer: FAAC S.p.A.Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALYDeclares that: The E124 control unit • ·conformstotheessentialsafetyrequirementsofthefollowingEECdirectives
2006/95/ECLowVoltageDirective 2004/108/ECElectromagneticCompatibilityDirective
Additional note: Thisproductunderwenttestsinatypicaluniformconfiguration (allproductsmanufacturedbyFAACS.p.A.).
Bologna,01March2014 TheManagingDirector A.Marcellan
These instructions are to be considered as a rapid guide for installation. The complete instructions can be downloaded at the following address: www.faacgroup.it
To access PROGRAMMING FROM PC, connect the USB cable to the dedicated connector and consult the relative instructions.
E124 control unit – rapid guide
Primary power feed from mains
withswitchingpowerfeed230/115 V~ - 50/60 Hz
Secondary power feed
24Vdc-16Amax.(min.20Vdc.-max.28Vdc.)
Power absorbed from mains
stand-by=4Wmax.~400W
Max. load for motor 7 A
Power feed for accessories 24 Vdc
Accessories max. current
24Vdcmax.500mABUS-2EASYmax.500mA
Battery charge current 180mA
Operating ambient tempeature (-20-+55)°C
Protective fuses for unit Allselfresetting
Protective fuses for power pack 2.5 A
Function logics Semiautomatic,Automatic, “step-by-step”Semiautomatic,Automaticwithreverseduringpause,Automaticstep-by-step,Safetydevicesautomatic,Safetydevicesstep-by-stepautomatic,“b”Semiautomatic,mixedlogic“bC”,
Dead-man,AutomaticwithtimerfunctionWork time Programmable(from0to9min50sec)Pause time Programmable(from0to9min50sec)
TECHNICAL SPECIFICATIONSMotor power Programmableon50levelsMotor speed Programmableon10levelsConnector inputs Switchingfeeder,Battery,
Decoder/Minidec/RP,X-COM,moduleXF433/868,USB
Terminal board inputs BUS-2EASY,InputsfromIN1toIN5,Travellimitdevice,Encoder.
Terminal board outputs Flashinglamp,Motors,Electricallock,OUT1,OUT2(programmable),power
feedtoaccessoriesProgramming 1stand2nd lev.with3keys(+,-,F)and
LCDdisplay.
3rdlev.withPCconnectedviaUSB
WARNINGS - Important!Forthesafetyofpeople,itisimportantthatalltheinstructionsbecarefullyobserved. - Incorrectinstallationorincorrectuseoftheproductcouldcauseseriousharmtopeople. - Carefullyreadtheinstructionsbeforebeginningtoinstalltheproductandkeepthemforfuturereference. - Thesymbol indicatesnotesthatareimportantforthesafetyofpersonsandforthegoodconditionoftheautomatedsystem. - Thesymbol drawsyourattentiontothenotesonthecharacteristicsandoperationoftheproduct. - Beforeattemptinganyworkonthecontrolunit(connections,maintenance),alwaysturnoffpower. - Install,upstreamofthesystem,adifferentialthermalbreakerwithadequatetrippingthreshold, - Connecttheearthcabletotherelevantterminal. - Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electricaldisturbance,useseparatesheathsorascreenedcable(withthescreenearthed).
2
+ +
DL1
SW7
J12
J4
M1A J14
J13 J15
J3
J5
J6 J7
J8 J9 J10 J11
J2
J1
M1A
DL20
DL14
DL13
DL18
DL11
DL17
DL10DL5
DL15
DL8
SW1
DL3 DL7DL6
SW6
SW3
SW4
DL16
DL12
DL19
DL9
SW2
SW5
LCD
DL2 DL4
EN
GL
ISH
LAYOUT AND COMPONENTS OF E124 BOARD
DESCRIPTION OF COMPONENTS
LCD SIGNALSANDPROGRAMMINGDISPLAY
SW1 “R1”PROGRAMMINGPUSH-BUTTON
SW2 “R2”PROGRAMMINGPUSH-BUTTON
SW3 “SETUP”PUSH-BUTTON
SW4 “+”PROGRAMMINGPUSH-BUTTON
SW5 “-”PROGRAMMINGPUSH-BUTTON
SW6 “F”PROGRAMMINGPUSH-BUTTON
SW7 “RESET SW”SOFTWARERESETPUSH-BUTTON
DL1 INPUTSTATUSCONTROLLED“IN1”DL2 INPUTSTATUSCONTROLLED“IN2”DL3 INPUTSTATUSCONTROLLED“IN3”DL4 INPUTSTATUSCONTROLLED“IN4”DL5 INPUTSTATUSCONTROLLED“IN5”DL6 INPUTSTATUSCONTROLLED“FCA1”DL7 INPUTSTATUSCONTROLLED“FCC1”
DL8 INPUTSTATUSCONTROLLED“FCA2”
DL9 INPUTSTATUSCONTROLLED“FCC2”DL10 INPUTSTATUSCONTROLLED“ENC1”(Gatecoder)DL11 INPUTSTATUSCONTROLLED“ENC2”(Gatecoder)DL12 LEDFORDEVICEBUS-2EASY ACTIVE
DL13 LEDFOR BUS 2-EASYDIAGNOSTICSDL14 LEDSIGNALLINGPRIMARYPOWERON
DL15 LEDSIGNALLINGSECONDARYPOWERON
DL16 LEDFOR“SW1” PUSH-BUTTON (R1 PUSH-BUTTON)
DL17 LEDFOR“SW2” PUSH-BUTTON (R2 PUSH-BUTTON)
DL18 LEDFOR“SW3” PUSH-BUTTON (SETUP PUSH-BUTTON)
DL19 PRESSURESIGNALLINGLED“RESET SW” PUSH-BUTTON
DL20 ALARMSIGNALLINGLED“ALARM”J1 POWERFEEDERSWITCHINGCONNECTOR
J2 SECONDARYPOWERSELECTOR
J3 CONNECTORFORCONNECTIONTOBUS-2EASYDEVICES
J4 CONNECTORFORTERMINALBOARDINPUTS
J5 CONNECTORFOROUT2OUTPUT(see2ndlevelprog.)
J6 TRAVELLIMITSCONNECTOR
J7 CONNECTORFORLEAF1ANDLEAF2ENCODERINPUTS
J8 CONNECTORFOROUT1OUTPUT(see2ndlevelprog.)
J9 FLASHINGLAMPOUTPUTCONNECTOR
J10 CONNECTORFORELECTRICALLOCKOUTPUT
J11 LEAF1MOTORCONNECTOR
J12 LEAF2MOTORCONNECTOR
J13 CONNECTORFORRECEIVERMODULEXF433/XF868
J14 CONNECTOR:DECODER/MINIDEC/RPRECEIVER
J15 USBCONNECTORFORPROGRAMMINGFROMPC
M1A ACCESSORIESMODULECONNECTOR
3
115 V ~ 230 V ~
EN
GL
ISH
LED OPERATION
POWER FEED
LED Description ON(contact closed)
OFF(contact open)
DL1 IN1 OPEN A Commandenabled Command disabled
DL2 IN2 OPEN B Commandenabled Command disabled
DL3 IN3 STOP
Command disabled Commandenabled
DL4 IN4FSWOP
Safety devices disabled Safetydevicestripped
DL5 IN5 - FSWCL
Safety devices disabled Safetydevicestripped
DL6 FCA1 Opening travel-limit devices free
Openingtravel-limitdevicesengaged
DL7 FCC1 Closing travel-limitdevicesfree
Closing travel-limit devices engaged
DL8 FCA2 Opening travel-limit devices free
Openingtravel-limitdevicesengaged
DL9 FCC2 Closing travel-limitdevicesfree
Closing travel-limit devices engaged
DL10 ENC1 Flashingduringoperation(Gatecoder)
DL11 ENC2 Flashingduringoperation(Gatecoder)
DL12 SIGNALLINGLEDFORDEVICEBUS-2EASY ACTIVE
DL13 SIGNALLINGLEDFOR BUS 2-EASYDIAGNOSTICS
DL14 LEDSIGNALLINGPRIMARYPOWERON
DL15 LEDSIGNALLINGSECONDARYPOWERON
DL16 LEDFOR“SW1” PUSH-BUTTON (R1 PUSH-BUTTON)
DL17 LEDFOR“SW2” PUSH-BUTTON (R2 PUSH-BUTTON)
DL18 LEDFOR“SW3” PUSH-BUTTON (SETUP PUSH-BUTTON)
DL19 LED“RESET SW” PUSH-BUTTON
DL20 ALARMSIGNALLINGLED“ALARM”
INPUTS DEFAULT SETTING Terminal-board J4IN1 OPEN A N.O. contactIN2 OPEN B N.O. contactIN3 STOP N.C. contactIN4 FSWOP N.C. contactIN5 FSWCL N.C. contact
J1: Select the correct power feed, by turning the power switchingselectortoitscorrectposition(Default230Vac.)
To ensure correct operation, the switching feeder must be connected to the earth conductor in the system. Install an adequate differential thermal breaker upstream of the system.
SECONDARY POWER FEED
J2:Intheabsenceofaprimaryfeedfromthemains,thecontrolunitcanbefedbyasecondarylowvoltage(24Vdc)powerfeed.Powercanbesuppliedbyapackofbatteries,rechargedbyabatterychargerintegratedintheboard,orbyastabilisedpowerfeeder.Inbothcases,thepowersupplymusthavethefollowingcharacteristics:
If you use an external stabilised feeder, you must disable the “battery charger” function via the PC (see dedicated instructions).
Voltage: (24 ± 4) VdcCurrent: 16 A max.
Connector J13 – XF Module (OMNIDEC)
Channel 1 OPEN AChannel 2 OPEN B
Connector J14 - Radio
Channel1RP OPEN AChannel2RP2 OPEN B
TERMINAL BOARD MOTORS
J11 (MOT1):Connectionofmotorconnected to leaf1, i.e. the leafwhichopensfirstduringanopeningoperation.
J12 (MOT2):Connectionofthemotorconnectedtoleaf2,i.e.theleafwhichopenssecond.
If only one motor is connected, it must be connected to terminal J11 (MOT1).
If, during the first movement of the SETUP procedure, the leaves open instead of closing, the motor connection cables must be changed over.
Flashing LED ALARM indicates alarm in progress (a situation which does not prejudice gate operation)
LED ALARM on steady light indicates error in progress (a situation which blocks operation until cause of error is eliminated)
4
**
*
TX CL
RX OP/CLTX OP/CL
+
++
+
ON
1 2 3 4
BUSBUSDL2
DL1
DS1ON
1 2 3 4
BUSBUS
DL2
DS1
RX - TX
TX
EN
GL
ISH
ELECTRICAL CONNECTIONS
Connectionoftraditionalsafetydevicesand
photocells
Enablein 2ndlevel
programming
UsewithmotorswithoutaBUS-2EASY encoder
Max load 24Vdc - 500mA
Connectionofapairofclosingphotocellsandapairofope-ning/closingphotocellswithdisabledFAIL-SAFEsafetydevice
and STOP
CONNECTION OF TRADITIONAL SAFETY DEVICES
ADDRESSING THE BUS-2EASY PHOTOCELLS
Important: the same address must be given to both transmitter and receiver. Make sure that there are not two or more pho-tocell pairs with the same address. If you are not using any BUS-2EASY accessory, leave free connector BUS-2EASY
PHOTOCELLS BUS-2EASY
DL1 =AlignmentDL2 = BUS-2EASY/powersupplystatusDS1 = Programmingdip-switches
Dip1 Dip2 Dip3 Dip4 Rif. Type
OFF OFF OFF OFF
B - C OPENING
OFF OFF OFF ON
OFF OFF ON OFF
OFF OFF ON ON
OFF ON ON OFF
OFF ON ON ON
ON OFF OFF OFF
D CLOSING
ON OFF OFF ON
ON OFF ON OFF
ON OFF ON ON
ON ON OFF OFF
ON ON OFF ON
ON ON ON OFF
OFF ON OFF OFFA OPENING
and CLOSINGOFF ON OFF ON
ON ON ON ON / OPEN PULSE
Thefollowingtableshowstheprogrammingoperationsofthedip-switchinsidethetransmitterandtheBUS2-EASYphotocellsreceiver.With the E124 control unit, you can use both traditional
photocells (N.C. contact with relay) and/or photocells with BUS-2EASY (open collector contact).
5
DL 2
DL 1
DL 3
DL 2
DL 1
DL 3
DL 2
DL 1
DL 3DL 2
DL 1
DL 3
EN
GL
ISH
ADDRESSING THE BUS-2EASY ENCODERSConnectionoftheBUS-2EASYinputinthecontrolboardisviathebipolarcableswhichcomeoutoftheencoders.
Unlike the case of the photocell devices, the polarity of the BUS-2EASY line connection determines whether the encoder belongs to one leaf rather than to the other.
DL1ON
DL3OFF
DL1ON
DL3OFFDL1ON
DL1ON
DL3OFF
LEAF 1* TWO LEDs ON
LEAF 1* TWO LEDs ON
LEAF 2ONE LED ON
REVERSE THE ENCODER WIRES TO EXCHANGE BETWE-EN THE ENCODER ASSOCIATED WITH LEAF 1 AND THE ENCODER ASSOCIATED WITH LEAF 2 AND VICE VERSA
LEAF 2ONE LED ON
* LEAF 1 OPENS AS FIRST AND CLOSES AS SECOND. IF NO REBATE IS PRESENT BETWEEN LEAF 1 AND 2, SET LEAF DELAY TO ZERO ON THE CONTROL BOARD.
DL2ON
DL3OFFDL2OFF
DL2ON
DL2OFF
* LEAF 1 OPENS AS FIRST AND CLO-SES AS SECOND. IF THERE IS NO REBATE BETWEEN LEAF 1 AND 2, SET THE LEAF DELAY TO ZERO ON THE CONTROL BOARD.
REVERSE THE ENCODER WIRES TO EXCHANGE BETWEEN THE EN-CODER ASSOCIATED WITH LEAF 1 AND THE ENCODER ASSOCIATED WITH LEAF 2, AND VICE VERSA
MAKE SURE THAT LED DL1 IS LIGHTED ON LEAF 2, WHEN THE MOTOR IS AT REST
LEAF 2ONE LED ON
MAKE SURE THAT LEDs DL1 AND DL2 ARE LIGHTED ON LEAF 1, WHEN THE MOTOR IS AT REST
LEAF 1 TWO LEDs ON
LEAF 1*
MAKE SURE THAT LED DL1 IS LIGHTED ON LEAF 2, WHEN THE MOTOR IS AT REST
LEAF 1 TWO LEDs ON
LEAF 2ONE LED ON
MAKE SURE THAT LEDs DL1 AND DL2 ARE LIGHTED ON LEAF 1, WHEN THE MOTOR IS AT REST
LEAF 1*
ENCODER WIRES REVERSING OPERATION
ENCODER LEAF 1
ENCODER LEAF 2
LEAF 2
LEAF 2
SAFECODER WIRING (Operators 412, 413, 415, 770N, S450H)
ENCODER WIRING FOR OPERATOR S700H/S800H
Leaf1 Leaf2
Leaf2 Leaf1
6
F F
-/R2+/R1F
F+
+/R1F
++/R1
EN
GL
ISH
PROGRAMMING
Programmingisdividedintwolevels:• BASIC programming• ADVANCED programming
Theprogrammingphasesare(seeTab.):1. toaccessPROGRAMMING(1A or 1B);2. toshowthesetvaluesandmodifythem,ifyouwant.Changing the values is effective immediately, while the final memorisation must be carried out
upon exiting programming (St ).3. exittheprogrammingbyusingSt function.SelectY toSAVEtheconfigurationyoujustperformed,otherwise select no toEXITWITHOUT
SAVINGanychanges.
You can EXIT programming at anytime:• press and hold F and then also -toswitchdirectlytoSt .
F+
-/R2
Thisboardalsoallowsprogramming using a PC or MAC.ThisprogrammingrequiresconnectiontoPC/MACviaUSBcableandUSB-Brelevantport.TheprogrammingSOFTWAREwithrelevantinstructions,mustbedownloadedfromthewebsite:
www.faacgroup.comTheprogrammingusingaPC/MAC,withthedefault PASSWORDdoesnotinhibittheprogrammingbyboard.ThewritingPC willbedisplayedincorrespondencewiththemodifiedvalues.Notes:whenyoumodifythevaluesbyboardthepreviousPC/MACprogrammingwillbeoverwrote.
The default password is 0000.
The programming using a PC/MAC, with a modified PASSWORD (different from the default one), will inhibit the programming by board. If one of the buttons is pressed, the display will show PC programming for 5 sec and changes will be allowed only by PC /MAC.
A B C
basi
c pro
gra
mm
ing
1a. press and hold F :the first function appears
ë1
release F:the function value
is displayedusing + or -,
scroll the available values
until the the desired one
press F:to move to
the next functionë1
function St(last basic or advanced
function)
adva
nced
pro
gra
mm
ing 1b. press and hold F and
then also + :the first function appearsë1
release the keys:the function value
is displayed
select Y to save the programming
otherwise
select no to exit the programming without
saving
ë1 the function is displayed until you hold
Tab. Programmingphases.
Connector J13 – XF MODULE rapid connectionThecontrolunithasanintegrated2-channeldecodingsystem(DS,SLH,LC/RC)namedOMNIDEC.Thissy-stemmakesitpossibletosave–throughanextrareceivermodule–XF433orXF868radiocommandsofthesamefrequency,butofadifferenttype(DS,SLH,LC/RC).Itispossibletosavebothtotalopening(OPENA)andpartialopening(OPENB)oftheautomatedsystem,uptoamaximumof256channels.
Insert and remove the boards only after cutting power.
7
EN
GL
ISH
BASIC PROGRAMMING
Display Basic Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5cF 0 ConfigurestheparameterswithDEFAULTvaluescor-
respondingtoaninstallationwithnon-FAACoperators.(seedefaultcolumn0).
1 Configures theparameterswithDEFAULTvaluescor-respondingtoaninstallationwithoperators FAAC 412, 413/415, 770, 390, 770N(seedefaultcolumn1).
2 ConfigurestheparameterswithDEFAULTvaluescor-respondingtoaninstallationwithoperators FAAC 391 (seedefaultcolumn2).
3 ConfigurestheparameterswithDEFAULTvaluescorre-spondingtoaninstallationwithoperators FAAC S700H/S800H (seedefaultcolumn3.
4 Configures theparameterswithDEFAULTvaluescor-respondingtoaninstallationwithoperators FAAC 418. (seecolumndefault4).
5 Configures the parameters with DEFAULT values corresponding to an installationwith operators FAAC S450H (seecolumndefault5).
PC MixedconfigurationfromaPC/MAC
At the time of changing the set motor type on the board, the relevant defaults are uploaded.
0 1 2 3 4 5
dF DEFAULT:
Y indicatesthatallthesetvaluescorrespondtothedefaultvalues.
no indicatesthatoneormoresetvaluesaredifferentfromthedefault.
Set Y ifyouwanttorestorethedefaultsettings.
Y Y Y Y Y Y
LO FUNCTION LOGICS:
E Semi-automaticEP Semi-automaticStep-by-StepS AutomaticSafetyDevicesSA AutomaticwithreversalduringpauseSP AutomaticStep-by-StepSafetyDevicesA1 Automatic1A AutomaticAP AutomaticStep-by-StepAt Automatictimerb Semi-automatic“b”bC Mixed(Pulses foropening /Dead-mancommandsfor
closing)C Dead-manCU LogicmodifiedfromaPC/MAC
Other more detailed programming possibilities are feasible by programming with a PC (see dedicated instructions).
E E E E E E
8
EN
GL
ISH
Display Basic Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5PA PAUSE TIME A (visualised only if the selected logic allows
automatic reclosing):PausetimefollowingaTOTALopeningcommand.Ithasonlyeffectifalogicwithpausetimewasselected.Canbeadjustedfrom0to59sec.inone-secondsteps.Next, the viewing changes in minutes and ten seconds(separatedbyadot)andtimeisadjustedin10-secondsteps,uptothemaximumvalueof9.5 minutes.E.g.: if the display shows 2.5 , the pause time will be 2 min. and 50 sec.
30 30 30 30 30 30
Pb PAUSE TIME B (visualised only if the selected logic allows automatic reclosing):
PausetimefollowingaPARTIALopeningcommand.Ithasonlyeffectifalogicwithpausetimewasselected.
30 30 30 30 30 30
Mn NR. OF MOTORS:Youcanselectthenumberofmotorspresentinthesystem:
1 =1motor2 =2motors
If the SETUP is performed with only one motor, and later two motors are used, the board will signal error 14 - configuration error, which can be deleted by re-peating the SETUP with two motors or by returning to one motor.
If a SETUP is performed with two motors and later only one is used, the board will not signal an error. Only the motor connected to input M1 will move.
When programming from a PC/MAC, you can select different partial openings.
02 02 02 02 02 02
F1 MOTOR 1 POWER :Youcanadjust themaximumpowerofmotor1,which is thesameduringbothopeningandclosing.
01 =minimumpower50 =maximumpower
If the power is modified, we recommend performing a new SETUP - see the related paragraph.
Other more detailed programming possibilities are feasible by programming with a PC (see dedicated instructions).
25 25 25 40 25 35
F2 MOTOR 2 POWER (visualised only with the function Mn = 2):Youcanadjust themaximumpowerofmotor2,which is thesameduringbothopeningandclosing.
25 25 25 40 25 35
SP SPEED:Adjuststhemotionspeedofthemotors.Thereare10levels.The value is relative and not absolute, because the speedvalue refers to the weight of the leaf measured during theSETUPcycle
0 1 =minimumspeed 1 0 =maximumspeed
Other more detailed programming possibilities are feasible by programming with a PC (see dedicated instructions).
08 08 08 08 08 08
9
EN
GL
ISH
Display Basic Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5En ENCODER USE:
Youcanenable/disable theuseof encoders (bothBUSandGATECODERencoders):Y =encodersonbothmotorsno =encodersdisabled
When using configurations 3 or 5 it is mandatory to use the encoder, no is not selectable
no no no Y no Y
FA LIMIT SWITCH WHEN OPENING:Letsyousetordisableuseoftheopeninglimitswitchonswing-leaves.
no =openinglimitswitchesdisabled01 =thelimitswitchdeterminesthestoppingofmotion02 =thelimitswitchdeterminesthestartofdeceleration
After having changed the value of this function, SETUP is required: the card will signal error 14 (configuration error) until the SETUP is performed again or until the previous value is restored
no no no no no no
FC LIMIT SWITCH WHEN CLOSING:Letsyousetordisableuseoftheclosinglimitswitchonswing-leaves.
no =closinglimitswitchesdisabled0 1 =thelimitswitchdeterminesthestoppingofmotion02 =thelimitswitchdeterminesthestartofdeceleration
After having changed the value of this function, SETUP is required: the card will signal error 14 (configuration error) until the SETUP is performed again or until the previous value is restored.
no no no no no no
Cd DELAY FOR CLOSING LEAF (visualised only with the fun-ction Mn = 2 ):Isthedelaytimeforstartingleaf1closingwithrespecttoleaf2.Makesitpossibletoavoidoverlappingofthetwoleaves.Adjustablefrom00 to 59 sec, in 1- second steps.Nextthevalue59,theviewingchangestominutesandtenthsofasecond(separatedbyadecimalpoint)andtimeisadjustedin10-secondstepsuptothemaximumvalueof3 minutes.
e.g.: if the display shows 1 .2 , the time is 1 min and 20 sec
05 05 05 05 05 05
bu BUS-2EASY DEVICES ENTRY:
See the related paragraph.no no no no no no
M2 MOTOR 2 dead-man DRIVE mode (visualised only with the function Mn = 2 )+/R1
OPENS(visualisingoP )untilthebuttonishelddown-/R2
CLOSES(visualisingcL )untilthebuttonishelddown
-- -- -- -- -- --
10
EN
GL
ISH
Display Basic Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5M1 MOTOR 1 dead-man DRIVE mode
+/R1 OPENS(visualisingoP )untilthebuttonishelddown
-/R2 CLOSES(visualisingcL )untilthebuttonishelddown
-- -- -- -- -- --
tL WORK TIME LEARNING (SETUP):See the related paragraph. -- -- -- -- -- --
St AUTOMATED SYSTEM STATUS:Youcanexitprogramming,choosingwhetherornottosavetheconfigurationyoujustperformed.
1. set the choice:Y toSAVEandEXITtheprogrammingno toEXITtheprogrammingWITHOUTSAVING
2. pressthebuttonFtoconfirm;attheendthedisplayreturnstovisualizetheautomated system status:
Y
00 =CLOSED01 =OPEN02 =Stationarythen“OPENS”03 =Stationarythen“CLOSES”04 =In“PAUSE”05 =duringOpening06 =duringClosing
07 =FAILSAFEinprogress08 = checking BUS-2EASY devices in progress09 =Pre-flashthen“OPENS”10 =Pre-flashthen“CLOSES”1 1 =Emergencyopen12 =EmergencycloseHP =Hold position
WARNING If power is lost to the board prior to confirmation (step 2.), all changes made will be lost.
F+
-/R2
You can EXIT programming at any time: press and hold F and then also - to switch directly to St .
11
EN
GL
ISH
ADVANCED PROGRAMMING
Display Advanced Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5bo TIME OF MAXIMUM POWER AT STARTING:
Youcansetthestartingtime.Duringstartthemotorsworkatmaximumpowerforstartingthemovement.Adjustablefrom 00 to 10 sec,in1-secondsteps(ignoringthepowerlevelselectedwithF1 and F2 ).
Other more detailed programming possibilities are feasible by programming with a PC (see dedicated instructions).
02 02 02 02 02 02
cS FINAL STROKE WHEN CLOSING (RAM STROKE) (NOT displayed if function FC = 1 ):Letsyouenable/disabletheramstrokeonswing-leaves.
Theramstrokefacilitateslatchingoftheelectriclockbyactiva-tingthemotorsatmaximumpowerduringfinalclosing.Y =enabled(for2sec)no =disabled
In case of systems with an absolute encoder, to ena-ble this function a setup must be performed using the automatic leaf stop on the mechanical contact point.
no no no no no no
rS REVERSE STROKE WHEN OPENING displayed if function FA = 1 ):Letsyouenable/disablethereversestrokeonleafdoors.The reversestroke facilitatesunlatchingof theelectric lock.Whentheautomaticsystemisclosed,beforestartingtoopen,themotorsgiveabriefpushtoclose.
Y =enabled(for2sec)no =disabled
In case of systems with an absolute encoder, to ena-ble this function a setup must be performed using the automatic leaf stop on the mechanical contact point.
no no no no no no
EL ELECTRIC LOCK ON LEAF 2:Theboardhasaterminaldedicatedtotheconnectionofanelectric lock. Normally the electric lock must be connectedto leaf 1. If theelectric lock is locatedon leaf 2, adjust theparameter.Thisparameterdoesnotallow thesettingY ifMn = 2 )Y =electriclockonleaf2no =electriclockonleaf1
no no no no no no
Od DELAY FOR OPENING LEAF (visualised only with the function Mn = 2 ):Youcansetthedelaytimeforstartingleaf2openingwithrespecttoleaf1,inordertoavoidoverlappingofthetwoleaves.Adjustablefrom00 to 59 sec, in 1- second steps.Nextthevalue59,theviewingchangestominutesandtenthsofasecond(separatedbyadecimalpoint)andtimeisadjustedin10-secondstepsuptothemaximumvalueof1 .3 minutes.e.g.: if the display shows 1 .2 , the time is 1 min and 20 sec.
02 02 02 02 02 02
12
EN
GL
ISH
Display Advanced Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5r1 LEAF 1 DECELERATION:
Youcanadjustthedecelerationspaceasapercentageofthetotaltravelofleaf1.Adjustablefrom 00 to 99 %, in 1% steps.
00 =nodeceleration01 =minimumdecelerationspace99 =maximumdecelerationspace
30 30 30 20 30 30
r2 LEAF 2 DECELERATION (visualised only with the function Mn = 2 ):Youcanadjustthedecelerationspaceasapercentageofthetotaltravelofleaf2.Adjustablefrom 00 to 99 %, in 1% steps.
00 =nodeceleration01 =minimumdecelerationspace99 =maximumdecelerationspace
30 30 30 20 30 30
PF PRE-FLASHING:Youcanenable/disablethepre-flashing.Pre-flashingduration=3sec.You can choose:no =disabledOC =pre-flashingbeforeeachmovementCL =pre-flashingbeforeaclosingmovementOP =pre-flashingbeforeanopeningmovementPA =pre-flashingonlyattheendofthepausetime
no no no no no no
Ph CLOSING PHOTOCELLS:Theinterventionofclosingphotocellscausesthereversingofautomatedsystem(opening).You can choose: Y =operate the reversal only after thephotocells are
released no =operatethereversalimmediately
no no no no no no
Ad ADMAP FUNCTION:Allowsoperation in compliancewithFrench regulationNFP25/362.Y =enabledno =disabled
no no no no no no
EC ANTI-CRUSHING SENSITIVITY:Varyingthisfunctionvariestheamountoftimeafterwhich,incaseofobstacle,theboardcommandsreversaloftheleaves,oritwillcommandastopiftheleavesareinthecontactpointsearchspace(seetheparameterrB ).Thefourthconsecutiveobstacledetectedinthesamedirectionandpositionwillbedefinedasacontactpointandtheleafwillstop in that position.0 1 =minimumsensitivity(maximumtimebeforereversal)10 =maximumsensitivity(minimumtimebeforereversal)
0 1 06 06 05 06 05
US ULTRA-SENSITIVITY:This functionactivatesanobstacledetectionsystem,basedonthecontrolofthevariationofthecurrentabsorbedbythemotor,causingimmediateleafreversal.
Y =activeno =excluded
no no no Y no Y
13
EN
GL
ISH
Display Advanced Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5rB MECHANICAL STOP SEARCH ANGLE (NOT displayed if
function FC or FA = 01 ):Youcanadjustthecontactpointsearchanglewithinwhichtheboardwillstopmovementwithoutreversing,ifitencountersanobstacleorthecontactpoint.Adjustablefrom 0.3 to 20 degrees.From0.3 to 9.9 degrees,adjustmentsaremadein0.1de-greesteps.From10 to 20 degrees,adjustmentsaremadein1degreesteps.
10 10 10 4.0 10 4.0
SF SOFT TOUCH: (visualised only with the function En = no):After touching the travel stoppoint, the leaves reverseandthenrestgently. Y =active no =excluded
This function can be useful to respect the impact curve specified by current standards.
O t h e r m o r e d e t a i l e d p r o g r a m m i n g possibilities are feasible by PC programming (see dedicated instructions).
no no no no no no
o 1 OUT 1:YoucansettheoutputOUT1(opencollectorN.O.)inoneofthefollowingfunctions:
00 = alwaysactive0 1 = FAIL-SAFE02 = INDICATORLIGHT(off=closed;on=duringopening
andopen/inpause;flashing=duringclosing)03 = COURTESYLIGHT(staysonforthedurationofthe
movement(eveninSETUP)inadditiontothesettimeoffunctiont1
04 = ACTIVEERROR05 = automatedsystemOPENorinPAUSE06 = automatedsystemCLOSED07 = automatedsystemMOVING08 = automatedsysteminEMERGENCY09 = automatedsysteminOPENING10 = automatedsysteminCLOSING1 1 = electric lock control before CLOSING12 = safetydeviceACTIVE13 = TRAFFICLIGHTfunction(activewhenOPENINGand
withautomatedsystemOPEN)14 = timedoutputwhichcanbeactivatedfromthesecond
radio channel OMNIDEC (seefunctiont1 )15 = outputwhichcanbeactivatedfromthesecondradio
channel OMNIDEC(step-by-stepfunction)16 = activeduringmovementofleaf117 = activeduringmovementofleaf218 = Instrusiondetection19 = Systemworkingonbattery
If tr is displayed, it indicates that the output is used as a TIMER set from the PC/MAC software.
00 00 00 00 00 00
14
EN
GL
ISH
Display Advanced Function Default 0 Default 1 Default 2 Default 3 Default 4 Default 5t1 OUT 1 TIMING (visualised only with the function o1 = 03
or o1 = 14 ):YoucanadjustthetimingofOUT1outputifatimedfunctionhasbeenselectedwithatimefrom1 to 59 minutesin1-minutestepsforfunctions03-14
0 1 0 1 0 1 0 1 0 1 0 1
o2 OUT 2:YoucansettheoutputOUT2(opencollectorN.O.).See the options as o1 .
02 02 02 02 02 02
t2 OUT 2 TIMING (visualised only with the function o2 = 03 or o2 = 14 ):
Adjustable as t1 .
0 1 0 1 0 1 0 1 0 1 0 1
AS MAINTENANCE REQUEST - CYCLE COUNTER (linked to the subsequent two functions):Youcanenable thesignalingofmaintenance request,or thecyclecounter.Y = enable the SIGNALINGwhen the programmed
number of cycles has been reached (as defined insubsequenttwofunctionsnc and nd ). Signalingconsistsofapre-flashingof8sec(inadditiontothetimemayalreadybesetwiththefunctionPF )beforeeachmovement.
no =enabletheCYCLECOUNTER,thatwillbedisplayedinthesubsequenttwofunctionsnc and nd up to a displayedmaximumof65,530.
If the number of cycles performed is greater than 65,530 the subsequent two functions nc and nd will display 65 and 53, respectively.
no no no no no no
nc CYCLE PROGRAMMING (THOUSANDS):IfAS =Y thedisplaywill show thenumberof thousandsofcyclesafterwhichthesignalingofmaintenancerequestbegins(canbesetfrom0 to 99 ).IfAS =no thedisplaywillshowthenumberofthousandsofworkcyclesperformed.Thevaluedisplayedisupdatedwiththesuccessionofthecycles,interactingwiththevalueinnd .
When AS = no you can reset the cycle counter: press simultaneously + and - for 5 sec.
00 00 00 00 00 00
nd CYCLE PROGRAMMING (TENS):IfAS =Y thedisplaywillshowthenumberoftensofcyclesafterwhichthesignalingofmaintenacerequestbegins(canbesetfrom0 to 99 ).IfAS =no thedisplaywillshowthenumberoftensofwork
cyclesperformed.Thevaluedisplayedisupdatedwiththesuccessionofthecycles,interactingwiththevaluein nc .
e.g.: if the system has performed 11,218 cycles, nc = 11 and nd = 21 will be displayed
00 00 00 00 00 00
15
EN
GL
ISH
BUS 2EASY DEVICE INSTALLATION
You can add BUS-2EASYdevicestothesystematanytime,proceedingasfollows:1. Cutofftheelectricalpowertotheboard.2. Install and set the BUS-2EASYaccessoriesaccordingtotheinstructionsofthedevices.3. Connect the BUS-2EASYdevicesaccordingtotheinstructionsofChapterELECTRICAL CONNECTIONS.4. Poweruptheboard.5. CompletetheprocedureforBUS-2EASYdeviceentry.
BUS-2EASY DEVICE ENTRY
1. AccessBASICprogrammingandscrollthroughthefunctionsupuntil bu .WhenFisreleased,thedisplaywillshowtheBUS-2EASY de-vicesstatus(see the figure).
2. Performtheentry:simultaneouslypressandhold+ and -foratleast5sec(duringthistime,thedisplaywillblink).3. Y willappearasaconfirmationofentrycompletion.4. Releasethe+ and -buttons.ThestatusoftheBUS-2EASYdeviceswillbedisplayed.
If no BUS device has ever been entered in the board, the display will read no.
Encoder 1:ON=correctlyconnectedandentered
Encoder 2:ON=correctlyconnectedandentered
BUS Status:alwaysON
OPEN photocell:ON=enteredandengaged
Opening photocells:ON=enteredandengaged
Closing photocells:ON=enteredandengaged
Fig. VisualisingtheBUS-2EASYstatusinthefunctionbu :eachsegmentofthedisplayshowsonetypeofdevice.
Opening photocellsand Closing photocells:ON=enteredandengaged
St AUTOMATED SYSTEM STATUS:Youcanexitprogramming,choosingwhetherornottosavetheconfigurationyoujustperformed.1. set the choice:Y toSAVEandEXITtheprogrammingno toEXITtheprogrammingWITHOUTSAVING2. pressthebuttonFtoconfirm;attheendthedisplayreturnstovisualizetheautomated system status:
Y
00 =CLOSED01 =OPEN02 =Stationarythen“OPENS”03 =Stationarythen“CLOSES”04 =In“PAUSE”05 =Opening06 =Closing
07 =FAILSAFEinprogress08 = checkingBUS-2EASY devices in progress09 =Pre-flashthen“OPENS”10 =Pre-flashthen“CLOSES”1 1 =Emergencyopen12 =EmergencycloseHP =Hold position
16
+/R1
EN
GL
ISH
InSTANDBY(gateclosedandinstand-by)withBUS-2EASY Encoderonleaf1andleaf2andBUS-2EASY Photocellscorrectlyconnectedandentered.
IncaseofBUS-2EASY Encoderonleaf1andleaf2andBUS-2EASY Photocells correctlycon-nectedandenteredandwithclosingphotocellsengaged:
Encoderonleaf1cor-rectlyentered
Encoderonleaf2cor-rectlyentered
atleastonepairofopeningphotocellscorrectlyentered
atleastonepairofclosing photocellscorrectlyentered
Fig. examplesofBUS-2EASYstatusvisualizationondisplay.
CHECKING THE SECURING DEVICES ENTERED ON THE BOARD
ToverifythetypesofBUSdevicerecognisedthroughtheentry:1. Press and hold the +buttonduringstand-byvisualisation;thesegmentscorrespondingtoatleastoneentereddevicewillgoON.E.g.:
TochecktheconditionoftheBUS-2EASYconnection,verifytheLEDontheboard:
LED DL15 (Red)
ON SafetydeviceengagedorpulsegeneratoractiveOFF NOsafetydeviceengagedneitherpulsegeneratoractive
LED DL14 (Green)
ON steady Normalactivity(ledONeveniftherearenodevices).
Slow blinking (blink every 2,5 sec) BUS-2EASY line short-circuit.
Rapid blinking (blink every 0.5 sec)
Error in the BUS-2EASY connection.Repeatthedeviceentry.Iftheerroroccursagain,check:-Thattherearenomorethanonedeviceinthesystemwiththesameaddress.-Callingerror(number>or<theconnectedBUSdevices).-FAILSAFEerrorontheBUSdevice.
OFF BoardinSleepmode(ifused).
TIME LEARNING - SETUPWhentheboardispowered,ifaSETUPhasneverbeenperformed,oriftheboardrequestsit,onthedisplayS0 indicatesthataSETUPmustbeperformed.
During SETUP, the connected BUS-2EASY accessories are always entered. The BUS-2EASY encoders entered by the SETUP must always be enabled using the parameter En (BASIC Programming).
During SETUP all safety devices are disabled! Therefore, carry out the operation avoiding any transit in the leaf movement area.
If a system without an encoder is installed, mechanical stops will be required for the leaves.
17
EN
GL
ISH
PerformtheSET-UPasfollows:
1. EnterBASICprogrammingandgototheparametertL ,whenFisreleased--willappear.2. Ensurethatthegateleavesareclosed.Otherwise,proceedasfollows: -Pressandhold-/R2tocloseleaf2 -Pressandhold+/R1tocloseleaf1
Should pressing +/R1 and/or -/R2 command opening of the corresponding leaf, cut off power and, on terminal board J11 or J12, invert the cables of the corresponding motor.
3. Withthegateleavesclosed,launchSETUPbypressingandholding+ and - until S1 beginstoflashonthedisplay(about3sec).4. Release+ e -.Leaf1beginsitsopeningmovement.
Operation WITHOUT SafecoderLeaf1automaticallyacknowledgesthemechanicalstop.
Operation WITH SafecoderLeaf1automaticallyacknowledgesthemechanicalstop.ItwillinanycasebepossibletostopleafmovementatanytimeandinthedesiredpointbysendinganOPENApulse.
5. OnthedisplayS2 willflash(onlyif2motorshavebeenselected):leaf2beginsopening.Operation WITHOUT Safecoder
Leaf2automaticallyacknowledgesthemechanicalstop.Operation WITH Safecoder
Leaf2automaticallyacknowledgesthemechanicalstop.ItwillinanycasebepossibletostopleafmovementatanytimeandinthedesiredpointbysendinganOPENApulse.
Steps 4 and 5 with function FA :
FA = 01 (the limit switch determines the stopping of motion) with Safecoder installed the OPEN A pulse for stopping motion is ignored.
FA = 02 (the limit switch determines the start of deceleration) send an OPEN A pulse only after involving the opening limit switch, without Safecoder, make sure that the limit switch is engaged before the mechanical stop.
6. OnthedisplayS3 willflash(onlyif2motorshavebeenselected):leaf2beginsclosing.Operation WITHOUT Safecoder
Leaf2automaticallyacknowledgesthemechanicalstop.Operation WITH Safecoder
Leaf 2 automatically acknowledges themechanical stop. Itwill in any case be possible to stop leafmovement at anytime and in the desired point by sending anOPENA pulse.
7. OnthedisplayS4 flashes:leaf1beginsclosing.
Operation WITHOUT SafecoderLeaf1automaticallyacknowledgesthemechanicalstop
Operation WITH SafecoderLeaf1automaticallyacknowledgesthemechanicalstop.ItwillinanycasebepossibletostopleafmovementatanytimeandinthedesiredpointbysendinganOPENApulse.
Steps 6 and 7 with function FC :
FC = 01 (the limit switch determines the stopping of motion) the OPEN A pulse for stopping motion is ignored.
FC = 02 (the limit switch determines the start of deceleration) with Safecoder installed send an OPEN A pulse only after involving the closing limit switch, without Safecoder, make sure that the limit switch is engaged before the mechanical stop
8. S5 flashesonthedisplay:bothleavesopenatfullspeed.9. Theboardwillautomaticallyexittheprogrammingmenuandwilldisplaytheautomatedsystemstatus(00 )toconfirmthattheSETUP
procedurehasbeencompletedcorrectly.Iftheprocedureisnotcompletedcorrectly,onthedisplayS0 willstartflashing,indicatingthatanewSETUPproceduremustbeperformed.
The deceleration spaces can be configured and modified from the display using the parameters r1 and r2 (see Advanced Programming) without repeating the SETUP.
TESTING THE AUTOMATED SYSTEM
Once installation and programming is completed, ensure that thesystemisoperatingcorrectly.Beespecially careful that the safety devicesoperate correctly andensure that thesystemcomplieswithallcurrentsafety regulations.Closethecoverintheprovidedseatwithgasket.
18
2” x 2OK
>5”
OPEN A
2” x 2OK>5”
OPEN B
<5”
<5”
OPEN A
OPEN B
EN
GL
ISH
MEMORISING THE RADIO CODE
Thecontrolboardfeaturesanintegrated2-channeldecodingsystem(DS,SLH/SLHLR,RC)calledOMNIDEC.Thissystemletsyoumemorise,usinganadditionalreceivermodule(onJ5connector)andmoreradiocontrolshavingdifferenttechnologybutthesamefrequency.Youcanthuscontrolbothtotalopening(OPENA)andpartialopening(OPENB).
The different types of radio code (DS, SLH/SLH LR, LC/RC) can coexist simultaneously on the two channels. You can enter up to 250 radio codes divided between OPEN A and OPEN B/CLOSE.
To use different encoding systems on the same channel, you must complete the learning of each encoding system and then repeat the procedure for the other one.
Other, more detailed, programming options are available using a PC/MAC (see dedicated PC/MAC instructions). For example, you can set an automatic OPEN command on the radio channel to command an automatic cycle (open-pause-close) regardless of the selected logic.
MEMORISING THE SLH/SLH LR RADIO CONTROLS
1. Pressandhold+/R1-SW1(OPENAprogramming)or-/R2-SW2(OPENB/CLOSEprogramming).2. Afterkeepingthebuttonpressedforabout5sec,thecorrespondingradioLED(DL11orDL12)willbegintoflashslowlyforabout20sec.3. Releasethebutton.4. SimultaneouslypressandholdP1andP2ontheSLH/SLHLRradiocontrol(onlyMASTERradiocontrol).5. TheradiocontrolLEDwillbegintoflash.6. Releasebothbuttons.7. EnsurethatLEDDL11orDL12ontheboardisstillflashing(seepoint2)and,whiletheradiocontrolLEDisstillflashing, press and hold the
desiredbuttonontheradiocontrol(theradiocontrolLEDwillgoonsteady).8. ThecorrespondingLEDontheboard(DL11orDL12)willgoonsteadyfor1secandthengooff,indicatingthatmemorisationhasbeen
completed.9. Releasetheradiocontrolbutton.10. Tocompletememorisation,pressthebuttonofthememorisedradiocontroltwiceinsuccession.Theautomatedsystemwillperforman
openingcycle.Ensure that there are no obstacles (by people or things) during the automated system movement.
19
Master
<5”
MasterNEW
MasterNEW
NEW
2” x 2
Master
OK
>5” OK
OPEN A
OPEN B
>5”
>5”
>5”
OPEN A
OPEN B
EN
GL
ISH
Toenableotherradiocontrolswiththesamesystemcode,youmusttransferthesystemcodeofthememorisedradiocontrolbuttontothebuttoncorrespondingtotheradiocontrolyouwishtoadd:1. SimultaneouslypressandholdP1andP2onthememorisedradiocontrol.2. TheradiocontrolLEDwillbegintoflash.3. Releasebothbuttons.4. Press and hold, whiletheradiocontrolLEDisstillflashing,thememorisedbutton(theradiocontrolLEDwillgoonsteady).5. Bringtheradiocontrolsclosetogether,pressandholdthecorrespondingbuttonoftheradiocontrolyouwishtoadd,andreleaseonlyafter
theradiocontrolLEDflashestwice,indicatingthatmemorisationhasbeencompleted.6. Pressthebuttonofthememorisedradiocontroltwiceinsuccession.Theautomatedsystemwillperformanopeningcycle.
Ensure that there are no obstacles (by people or things) during the automated system movement.
MEMORISING LC/RC RADIO CONTROLS (433MHz ONLY)
1. Pressandhold+/R1-SW1(OPENAprogramming)or-/R2-SW2(OPENB/CLOSEprogramming).2. Afterkeepingthebuttonpressedforabout5sec,thecorrespondingradioLED(DL11orDL12)willbegintoflashslowlyforabout20sec.3. Releasethebutton.4. DuringradioLEDflashing,pressthedesiredbuttonoftheLC/RC radio control.5. ThecorrespondingLEDontheboard(DL11orDL12)willgoonsteadyfor1second,indicatingthatmemorisationhasbeencompleted,and
willbeginflashingagainforanother20secduringwhichyoucanmemoriseanotherradiocontrol.6. Whenthe20sechaveelapsed,theLEDwillturnoff,indicatingthattheprocedurehasbeencompleted.7. Toaddotherradiocontrols,repeattheprocedurefrompoint
REMOTE MEMORISATION OF LC/RC RADIO CONTROLS
WithLC/RCradiocontrolsyoucanremotelymemoriseotherradiocontrols,i.e.withoutworkingdirectlyontheboard,usingapreviouslyme-morisedradiocontrol.1. Takearadiocontrolthathasalreadybeenmemorisedononeofthe2channels(OPENAorOPENB/CLOSE)andmovetothevicinityof
theboard.2. SimultaneouslypressandholdP1andP2untilbothLEDsflashslowlyfor5sec.3. Within5seconds,pressthepreviouslymemorisedradiocontrolbuttontoactivatethelearningphasefortheselectedchannel.4. TheLEDontheboardcorrespondingtothechannelinlearningmodewillflashfor20secwithinwhichanotherradiocontrolcodeistransmit-
tedbypressingthebutton.5. ThecorrespondingLEDontheboardwillgoonsteadyfor2sec(indicatingthatmemorisationhasbeencompleted)andwillbeginflashing
againforanother20sec,duringwhichyoucanmemoriseotherradiocontrols,andwillfinallygooff.
20
OK
>5” OK
OPEN A
OPEN B
>5”
OPEN A
OPEN B
EN
GL
ISH
MEMORISING DS RADIO CONTROLS
1. On the DSradiocontrol,choosethedesiredON-OFFcombinationofthe12dip-switches.2. Pressandhold+/R1-SW1(OPENAprogramming)or-/R2-SW2(OPENB/CLOSEprogramming).3. Afterkeepingthebuttonpressedforabout5sec,thecorrespondingradioLED(DL11orDL12)willbegintoflashslowlyforabout20sec.4. Releasethebutton.5. DuringradioLEDflashing,pressthebuttonoftheradiocontrolyouwishtoprogram.6. ThecorrespondingLEDontheboard(DL11orDL12)willgoonsteadyfor1secondandthengooff,indicatingthatmemorisationhasbeen
completed.7. Toaddotherdifferentcodes,repeattheprocedurestartingfrompoint1.8. Toaddotherradiocontrolswiththesamecode,setthe12dip-switchesaccordingtothesamecombinationasthealreadymemorisedradio
control.
DELETING THE RADIO CONTROLS
This operation CANNOT be reversed. This will delete ALL the radio control codes memorised as both OPEN A and OPEN B/CLOSE. The cancellation procedure is active only in gate status visualisation mode.
1. Pressandhold-/R2-/R2 .
2. Afterpressingforabout5sec,theDL12LEDbeginstoflashslowly;afteranother5secofslowflashingandholding,theLEDsDL11andDL12beginflashingmorerapidly(cancellationhasstarted).
3. Oncerapidflashinghasstopped,LEDsDL11andDL12willgoonsteady,confirmingthecancellationofalltheradiocodes(OPENAandOPENB/CLOSE)fromtheboardmemory.
4. Release-/R2-/R2
.TheLEDswillgooff,indicatingcorrectcancellation.
SELECTEDCODE
SELECTEDCODE
21
EN
GL
ISH
SIGNALLING ERRORS AND ALARMSIncaseofERRORS(conditionsthatstopgateoperation)orALARMS(conditionsthatdonotcompromisegateoperation)thedisplaywillshowthenumbercorrespondingtothewarninginprogressbysimultaneouslypressing+ and -.
These warnings will disappear in the following cycle only if the situation causing them is removed.
Errors
When there is an ERROR the ERROR LED will go on steady. By simultaneously pressing + and - the display will show the corresponding error number.
Thefollowingtablecontainsalltheerrorsthatcanbeviewedonthedisplay.
N° ERROR SOLUTION
0 1 Boardbroken Replacetheboard
0 5 InvalidSETUP RepeatboardSETUP
0 8 BUS-2EASYdeviceerror Ensurethatnotwopairsofdeviceshavethesameaddress.
0 9 BUS-2EASY output short-circuit
Checktheconnectionsoftheconnectedandentered BUS-2EASYdevices
1 0 Motor1limitswitcherror Checkthelimitswitchconnectionsformotor1
1 1 Motor2limitswitcherror Checkthelimitswitchconnectionsformotor2
1 2 BUS-2EASY call EnsurethattheBUSdevicesareoperatingcorrectlyand,ifnecessary,repeatBUSdeviceacquisition
1 3 FAIL SAFE Checkthatthesafetydevices(photocells)areoperatingcorrectly
1 4 Configurationerror Checkthattheboardisconfiguredcorrectly(basicandadvancedprogramming)and,ifnecessary,repeatSETUP
1 7 Motor1encoderfault Checktheconnectionsorreplacemotor1encoder
1 8 Motor2encoderfault Checktheconnectionsorreplacemotor2encoder
1 9 Incorrectmemorydata RepeatBUS-2EASYdeviceentryand/orre-programtheboard
9 3 Highabsorptionat+24V Checkthatabsorptionbytheaccessoriesconnectediswithinpermittedlimits
Alarms
When there is an ALARM the ERROR LED will begin to flash. By simultaneously pressing + and - the display will show the correspon-ding alarm number.
Thefollowingtablecontainsallthealarmsthatcanbeviewedonthedisplay.
N° ALARM Solution/Description
2 0 Obstacle onMOTOR 1 (only withencoder) Removeanypossibleobstacleonleaf1
2 1 Obstacle onMOTOR 2 (only withencoder) Removeanypossibleobstacleonleaf2
2 5 LOCK1outputshort-circuit Removethecauseoftheshort-circuit
2 6 LOCK2outputshort-circuit Removethecauseoftheshort-circuit
2 7 Nr.ofconsecutiveobstaclesexceededduringopening
Removeanypossibleobstacle.Shouldtheproblempersist,repeatSETUP
2 8 Nr.ofconsecutiveobstaclesexceededduringclosing
Removeanypossibleobstacle.Shouldtheproblempersist,repeatSETUP
3 0 XFradiocodememoryfull CanceltheradiocodesthatarenotbeingusedusingthePCprogramoruseanadditionalDEC/MI-NIDEC/RPmodule
3 1 Tamperingalarm MovementwasperformedwithautomationinstatusSt=00 or 01.Performamanoeuvrecycle.3 5 TIMERactiveandTIMERfunctionope-
rating: TIMERfunctionisoperating
4 0 Servicerequest Contacttheinstallerformaintenance
5 0 TheHOLDPOSITIONisoperating(ac-tiveonPC/MAC) HOLDPOSITIONfunctionisoperating
6 0 TIMERactiveanderrorinTIMERdata ReloadacorrectTIMERconfigurationwiththePC/MACprogramme
6 2 Loss of time and date on the board(onlyiftheTIMERisoperating) ReloadthetimeanddatewiththePC/MACprogrammeandreplacetheBAT1-CR2032bufferbattery
6 3 JOLLYTIMERisactivated JOLLYTIMERisenabledbyterminalboardJ3
6 4 TIMERDISABLEDisoperating TIMERisdisabledbyterminalboardJ3
SEDE - HEADQUARTERSFAAC S.p.A.Via Calari, 1040069 Zola Predosa (BO) - ITALYTel. +39 051 61724 - Fax +39 051 758518www.faac.it - www.faacgroup.com
SUBSIDIARIESAUSTRIAFAAC GMBHSalzburg - Austriatel. +43 662 8533950www.faac.atFAAC TUBULAR MOTORStel. +49 30 56796645faactm.info@faacgroup.comwww.faac.at
AUSTRALIAFAAC AUSTRALIA PTY LTDHomebush, Sydney - Australiatel. +61 2 87565644www.faac.com.au
BENELUXFAAC BENELUX NV/SABrugge - Belgiumtel. +32 50 320202www.faacbenelux.comFAAC TUBULAR MOTORStel. +31 475 406014faactm.info@faacgroup.comwww.faacbenelux.com
CHINAFAAC SHANGHAIShanghai - Chinatel. +86 21 68182970www.faacgroup.cn
FRANCEFAAC FRANCESaint Priest, Lyon - Francetel. +33 4 72218700www.faac.frFAAC FRANCE - AGENCE PARISMassy, Paris - Francetel. +33 1 69191620www.faac.frFAAC FRANCE - DEPARTEMENT VOLETSSaint Denis de Pile - Bordeaux - Francetel. +33 5 57551890www.faac.fr
ASSISTENZA IN ITALIASEDEtel. +39 051 6172501www.faac.it/ita/assistenza
FIRENZEtel. +39 055 301194filiale.firenze@faacgroup.com
GERMANYFAAC GMBHFreilassing - Germanytel. +49 8654 49810www.faac.deFAAC TUBULAR MOTORStel. +49 30 5679 6645faactm.info@faacgroup.comwww.faac.de
INDIAFAAC INDIA PVT. LTDNoida, Delhi - Indiatel. +91 120 3934100/4199 www.faacindia.com
IRELANDNATIONAL AUTOMATION LIMITEDBoyle,Co. Roscommon - Irelandtel. +353 071 9663893 www.faac.ie
MIDDLE EASTFAAC MIDDLE EAST FZEDubai Silicon Oasis free zonetel. +971 4 372 4187www.faac.ae
NORDIC REGIONSFAAC NORDIC ABPerstorp - Swedentel. +46 435 779500www.faac.se
POLANDFAAC POLSKA SP.ZO.OWarszawa - Polandtel. +48 22 8141422www.faac.pl
RUSSIAFAAC RUSSIA LLCMoscow - Russiatel. +7 495 646 24 29www.faac.ru
MILANOtel +39 02 66011163filiale.milano@faacgroup.com
PADOVAtel +39 049 8700541filiale.padova@faacgroup.com
ROMAtel +39 06 41206137filiale.roma@faacgroup.com
TORINOtel +39 011 6813997filiale.torino@faacgroup.com
SPAINCLEM, S.A.U.S. S. de los Reyes, Madrid - Spaintel. +34 091 358 1110www.faac.
SWITZERLANDFAAC AGAltdorf - Switzerlandtel. +41 41 8713440www.faac.ch
TURKEYFAAC OTOMATİK GEÇİS SİSTEMLERİSAN. VE TİC. LTD. ŞTİ.Çağlayan, Kağıthane, İstanbul - Turkeytel.+90 (0)212 – 3431311www.faac.com.tr
UNITED KINGDOMFAAC UK LTD.Basingstoke, Hampshire - UKtel. +44 1256 318100www.faac.co.uk
U.S.A.FAAC INTERNATIONAL INCRockledge, Florida - U.S.A.tel. +1 904 4488952www.faacusa.comFAAC INTERNATIONAL INCFullerton, California - U.S.A.tel. +1 714 446 9800www.faacusa.com
732569 - Rev.D