efka industry 4
Post on 18-May-2022
12 Views
Preview:
TRANSCRIPT
®
EFKA Industry 4.0
USER MANUAL
© 2019 BIASYS Systempartner GmbH
2
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Table of Contents
1. Introduction 4
2. Biasys I4 Frontend 7
2.1 Frontend Login .................................................................................................................... 8
2.2 Frontend Application ........................................................................................................ 10
Management ............................................................................................................... 102.2.1User .................................................................................................................................................................. 122.2.1.1
Machine .......................................................................................................................................................... 132.2.1.2
Service Call ID ................................................................................................................................................ 142.2.1.3
Sewing Machine Group ................................................................................................................................ 162.2.1.4
Add or Remove Machine ........................................................................................................................ 192.2.1.4.1
Get Parameter File from DB ................................................................................................................... 202.2.1.4.2
Production ................................................................................................................... 212.2.2Machine Status .............................................................................................................................................. 222.2.2.1
Machine Detail ........................................................................................................................................ 252.2.2.1.1
Machine Status Log ................................................................................................................................. 262.2.2.1.2
Service ....................................................................................................................................................... 272.2.2.1.3
Single Parameter <= Machine ....................................................................................................... 292.2.2.1.3.1
Selected Parameter by File <= Machine ...................................................................................... 302.2.2.1.3.2
Selected Parameter <= Machine ................................................................................................... 322.2.2.1.3.3
All Parameter <= Machine ............................................................................................................. 342.2.2.1.3.4
Single Parameter => Machine ....................................................................................................... 352.2.2.1.3.5
Selected Parameter by File => Machine ...................................................................................... 372.2.2.1.3.6
All Parameter => Machine ............................................................................................................. 382.2.2.1.3.7
Parameter File <=> Database ........................................................................................................ 402.2.2.1.3.8
Set Piece Counter ............................................................................................................................. 432.2.2.1.3.9
Set Service Counter .......................................................................................................................... 432.2.2.1.3.10
Save Parameter File ........................................................................................................................ 442.2.2.1.3.11
All Active Service Calls ........................................................................................................................... 452.2.2.1.4
Statistic ........................................................................................................................................................... 462.2.2.2
Service Call Log .............................................................................................................................................. 482.2.2.3
Settings ........................................................................................................................ 502.2.3Window Configuration ................................................................................................................................ 512.2.3.1
Setup ................................................................................................................................................................ 522.2.3.2
Language Setup ........................................................................................................................................ 522.2.3.2.1
Communication Server Setup ................................................................................................................ 522.2.3.2.2
Frontend Server Setup ............................................................................................................................ 532.2.3.2.3
House Keeping ......................................................................................................................................... 562.2.3.2.4
Archive Data ..................................................................................................................................... 582.2.3.2.4.1
Touch Mode Setup ................................................................................................................................... 602.2.3.2.5
3. EFKA Communication Server 62
3.1 Efka Communication Server Login ................................................................................... 63
3
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Table of Contents
3.2 Efka Com Server Application ............................................................................................ 65
4. Log From DB 66
5. Log Viewer 69
6. Database 73
6.1 i4_management ................................................................................................................. 74
User - Table ................................................................................................................. 756.1.1
Machine - Table .......................................................................................................... 776.1.2
Other - Table ............................................................................................................... 796.1.3
6.2 i4_production .................................................................................................................... 82
DailyStatistic - Table ................................................................................................... 846.2.1
MachineStatus - Table ................................................................................................ 856.2.2
Other - Tables ............................................................................................................. 876.2.3
Tables for pass-through command / responses to sewing machine control box and vice versa ..... 916.2.4
Index 0
Introduction
5
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Introduction
1 Introduction
This document is the user manual for the EFKA Industry 4.0 Software Solution (also called as Efka
BigData).
Efka I4 solution inter connects the sewing machines equipped with Efka Control Boxes
(e.g.ABxxxxx). It acquires the 'sewing data' as specified below from the connected Control Boxes:
· The detailed sewing information
· Service calls generated by the control box itself or by the operator on the sewing machine or
by the sensors connected to the machine
Efka I4 solution stores the acquired 'sewing data' to the database. It computes the statistics based
on the acquired 'sewing data' and maintains the sewing 'parameter data sets' in the database.
'parameter data sets' are the parameters related to the product to be produced on the machines.
Upload/download of 'parameter data sets' from/to the sewing machine control boxes are
possible from this Efka solution. It maintains a machine database and user database for the
sewing machine operators and the sewing machine service technicians.
Efka I4 solution provides data logging, which is a process of storing data over a period of time in
order to analyze application mechanism during the application information or errors. This log data
can be analyzed by reading the log files by the log viewer software as shown in Log Viewer
The solution mainly consists of the following software components:
· Server
Server is equipped with specific software application programs. Server is enabled to provide
services to the program called clients on its network. Server program accepts and responds to
the request made by the client on its network. The main function of a server is to store, retrieve
and manage all the application data in the database. Efka software solution contains server
application called 'EFKA Communication Server' also called as 'Com Server' as shown in Efka
communication server . Com server application provides service by responding to the
request made by the clients on the specific network IP Address.
· Client
Client is a device or software that access a service or resources shared by a server. The clients in
Efka software solution are as follows:
- Control Boxes
70
63
6
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Introduction
- Frontend application as described in Biasys I4 Frontend
These control boxes and the frontend application are connected to the com server on a specific
network IP Address and port number. The data communication like sending and receiving
message between server and client application is recorded by the software in MySql database.
8
Biasys I4 Frontend
8
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2 Biasys I4 Frontend
Introduction
Frontend is a Graphical User Interface (GUI) application, to manage the sewing machine data in
the database. The data acquired by the com server application during the production is stored in
the database, this particular data is read by the frontend application.
Frontend maintains the detail view of all the connected control boxes to the com server
application. User has the permission to insert or update the data values to the specific data
tables. It enables the grouping of sewing machines and to set the parameter from file based on
sewing machine groups. The service calls generated from the machine or the operator can be
handled using frontend. The performance of the sewing machine or the sewing machine user are
evaluated by the software. It also monitors the time taken by the mechanic to service the sewing
machine during the service call. It provides the data backup and cleanup functionality to maintain
old data during the specific time period. In general, frontend application reads the complete
sewing data from the database where user can access this data or insert the new data into the
database.
Remark: When frontend application is starting for the first time, it must be started as an
administrator twice because of application license.
2.1 Frontend Login
Introduction
On the start of the frontend application, the frontend login window pops up. The user must login
with the database server credentials in this window. The frontend application mechanism is
logged, in case of any errors or information.
9
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Frontend Login Window
Description
Frontend login window contains the MySQL database server credentials which must be filled by
the operator to access the frontend application. The operator must make sure about the database
server host and the user details, where the Efka I4 production data is present in the MySQL
workbench.
· Database server host: Database server name to which the frontend application must be
connected to retrieve the data
· User Name: User name which is specified in the database user accounts in the 'Users and
Privileges' section of MySQL workbench
· Password: Password specified for the respective user name in the database
- If the password does not exist for the particular user, this field can be empty
Once the database server host, user name and password entered, the database connection can be
verified by clicking Check button. If the database connection is successful for the entered
credentials, the following window is displayed:
If the database connection does not exists for the entered credentials, the following window is
displayed
10
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
· Application Logging: Frontend application logging information stores the frontend application
information or application errors. The frontend application information is logged based on the
option selected as follows:
- Log All: Logs all the frontend application data
- Only Errors: Logs only the error messages
- Errors and Last Infos: Logs only errors and the last information
- No Logging: No logging of any data in the frontend application
When all the required fields are entered, click Login button to start the frontend application
Button Description
Checks the database connection for the entered values and display the result
Login· Applies the database credentials entered
· Starts the frontend application if the database connection was successful or elsedisplay the error window
Cancel Exits the complete program
2.2 Frontend Application
Front End application has three main sections:
· Management
· Production
· Settings
2.2.1 Management
Introduction
11
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Management section contains the primary data related to the sewing machine and the sewing
machine user. The data in this section is inserted or modified by the com server application or by
the frontend operator.
Industry4 Front End (Management Section)
Description
The four main forms of the Management section are:
· Users
· Machine
· Service Call ID
· Sewing Machine Group
12
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.1.1 User
Introduction
The User form is the list of sewing machine user information. The sewing machine user could be
either an operator or a mechanic, explained as follows:
- Operator: The one who operates the sewing machine to perform the sewing task
- Mechanic: The one who services the sewing machine during the service calls
The administrator of the system must enter all the user data in the user table before any user can
login to the sewing machine. This form permits the user to add, delete or update data to the
database.
Management - User Form
Description
· RFID: ID from the RFID chip or the value entered in the efka variocontrol device during the
user login
- The RFID value must always be a 10 digit value
- Example: If the value entered in Efka variocontrol = 1234
- The RFID value in the user table will be = 0000001234
- The RFID field is formatted automatically to the 10 digit value once the mouse is clicked
out of the RFID field
· Real User Name: Full name of the sewing machine user
· Short User Name: Short unique user name, this is the name displayed in the EFKA variocontrol
(must be a unique value)
· Description: Enter the description for the particular user entered (The field value can also be
empty)
13
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
· EFKA User Group: Select if the user is an Operator or Mechanic from the drop down box
appeared
Click the save button to save the user data entered in the table. The user can also edit the old
data in the table.
Button Description
Refreshes the User data tableReverts any unsaved changes made to the table
Saves the changes made in the User table to the database
Exports the User data in the table to Excel file
2.2.1.2 Machine
Introduction
Machine table is the list of sewing machines connected to the com server application. Machine
table contains the detailed information regarding all the sewing machines that are connected to
the com server application. The data in this table is entered by the communication server (com
server) application when the new machine is connected.
Management - Machine Form
Description
· Machine ID: Sewing machine ID - Must be entered to the Efka control box by 799
· Server ID (Non-Editable): IP Address of the connected communication server
· Circuit Board No (Non-Editable): Sewing machine Circuit Board Number
· Serial No (Non-Editable): Efka control box Serial Number
· IP Address (Non-Editable): IP Address of the sewing machine control box connected to the com
server application
14
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
All the above values are inserted by the com server application when the connection is
established between the com server and the sewing machine client control box.
· Description (Editable): This is the only field editable by the user in Machine table and can save
the changes to the database
- The default value of this field is 'NEW RECORD' which is entered by the software
- Any particular description for the specific machine can be entered and saved
Button Description
Refreshes the Machine data tableReverts any unsaved changes made to the table
Saves the changes made in the Machine table to the database
Exports the Machine table data to Excel file
2.2.1.3 Service Call ID
Introduction
Service Call ID table is the list of detailed information of the complete service call. The service
calls are generated either by the sewing machine or by the sewing machine operator or by the
sensors connected to the machine. Each service call have a unique ID mentioned in this table.
Example: The following are the service calls generated from the operator during:
· Broken needle
· Broken Bobbin
· Broken knife
· Refill oil
· Broken thread
15
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Management - Service Call ID Form
Description
· Service call ID (Non-Editable): Each service call event is identified by this unique ID
- Service call ID is the service call number attached to a service call message
· Service call Event (Editable): Each respective ID has a unique event, which specifies what each
service call means
- This field can be modified and saved to the database
· Source (Non-Editable): Specifies the owner of the service call who can send the particular
service call event
· Category (Editable): Specifies the priority level of each service call event, which are categorized
as follows:
16
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- High Priority
- Middle Priority
- Low Priority
This priority can be configured based on the customer requirements. This field can be modified in
this table.
Button Description
Refreshes the Service Call ID data tableReverts any unsaved changes made to the table
Saves the changes made in the Service Call ID table to the database
Exports Service Call ID table data to Excel file
2.2.1.4 Sewing Machine Group
Introduction
Sewing Machine Group table is the list of sewing machine group and its corresponding list of
machines in the particular sewing machine group. This form contains sewing machine group table
and a detail table as follows:
· Sewing machine group table contains the sewing machine group based on the specific
requirements
· Detail table contains the list of machines present in the particular sewing machine group
These grouped machines are used to set the parameters from file. Setting parameter for the
particular group is possible once the parameter files are attached to the list of machines in the
particular group.
17
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Management - Sewing Machine Group Form
Description
User can create a new sewing machine group with unique 'Group Name' and specific 'Description'.
Step by step procedure to add the sewing machine to the particular group and to add the
parameter file for the respective sewing machine are as follows:
To add the sewing machine to the selected group
· Select the particular sewing machine group and click button to add the sewing machine to
the selected group
- By clicking on Add or Delete Machine button will open the form with the list of sewing
machines as shown in Add or Remove Machine
To add the parameter file to the selected machine
· Select the machine rows (to select multiple machine use 'ctrl' or 'shift' button) in the group
- Click Add Parameter File button to select the parameter file for selected machine
19
18
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- Add Parameter File button will open the form with list of parameter files from the
database as shown in Get Parameter File from DB
- Same parameter file can be attached to one or many machines in the group
· After adding parameter files to all the machines in the group, click Save button and click
Set Parameter button which displays the confirm window as shown below
- Click 'Yes' to continue to set parameter for the selected group of machines or else click 'No'
· If 'Yes' button is clicked, the progress window will arrive as shown below
- The window specifies the machine ID of currently processing sewing machine
- Once the process is completed the following window is closed
- The whole set parameter process can be canceled at any time by clicking 'Cancel' button
- If the cancel button is clicked, the set parameter process stops for the particular sewing
machine group and the following window is closed
While setting parameter, the 'Progress' column of the machine detail table display the progress
set parameter process
· The count displayed in the 'Progress' column is the set parameter count for the respective
machine and the parameter file
· The 'Progress' column display one of the status as shown below, once the set parameter
process is executed for the particular sewing machine group
- Completed: The set parameter process is set successfully
- No Parameter File: The parameter file is not added for the particular machine
20
19
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- Canceled: The set parameter process is canceled by the user
- Failed: The set parameter process failed
Sewing Machine Group Form: Set Parameter Process
Button Description
Refreshes Sewing Machine Group data table Reverts any unsaved changes made to the table
Saves the changes made in the Sewing Machine Group table to thedatabase
Exports Sewing Machine Group data in the table to Excel file
Add or Delete Machines from the Selected Group
Add Parameter file for the selected Machine
Sets parameter for all the machine in the selected group
2.2.1.4.1 Add or Remove Machine
Introduction
20
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Add or Remove Machine table is the list of all sewing machines connected to the com server
application. It provides the detail information of the sewing machine. In this form user has the
option to insert or remove the sewing machine from the particular sewing machine group.
Description
· To add the machine to the selected group, click on the 'Selection' field (tick mark means
selected) and click OK button
· To remove the machine from the selected group, click on the 'Selection' field (click on the tick
mark to remove) of particular machine to be removed and click OK button
· If 'Cancel' button is clicked, this form is closed without any modifications to the selected sewing
machine group
Add Machine or Remove Machine
2.2.1.4.2 Get Parameter File from DB
Introduction
Get Parameter File from DB table is the list of parameter files in the database. Only one
parameter file can be selected from this table. The selected parameter file data is retrieved to
the selected sewing machine.
Description
21
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
· Click on the parameter file to view the data of that particular file in the field below the
parameter file list
· The selected file name is displayed in the region below the parameter file list
· Select one parameter file in the list, and click this button
· The data from the selected parameter is retrieved for all the selected machine
· Or double click on the particular parameter file row to get the file data to the selected machine
Get Parameter File from Database
2.2.2 Production
Introduction
Production section contains the current production data of all the sewing machines connected to
the com server. It provides an overview of complete sewing data stored in the database. The data
in the production section cannot be modified. It monitors the status of the connected machines.
22
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
The data are categorized based on the user or machine. It provides statistics based on sewing
machine or sewing machine user. It maintains the service call information of the sewing machine.
Description
The three main formulas of Production section are:
· Machine Status
· Statistic
· Service Call Log
Industry4 Front End (Production Section)
2.2.2.1 Machine Status
Introduction
Machine Status table is the list of sewing machines and its current status. The list of sewing
machines are the sewing machines which are connected to the com server. The table contains the
detailed information of the connected sewing machines.
23
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Machine status form contains four sub forms which gives a detailed description of the data in the
machine status table. Each machine detail can be viewed independently. It maintains the
machine statistics of each sewing machine. It provides specific service functionality for each
sewing machine. It determines the active service call of the machine and provides the permission
to acknowledge the active service call.
Production - Machine Status Form
Description
· State: Specifies the current status of the machine as following
- On: If the sewing machine is switched on - Blue Color
- LoggedIn: If the user has logged-in to the specific machine - Green Color
- Service: If the mechanic has logged-in to the specific machine for servicing the machine - Red
Color
- Off: If the machine is switched off - Grey Color
If the user logout of the machine, the 'State' field value will be 'On' for that particular machine
· Machine ID: Specifies the machine ID of the particular machine
· Real User Name: Specifies the logged-in user name, if the user has an entry in the user table
with the respective RFID
- If the logged-in user does not have an entry in the user table, the real user name is 'Unknown'
· Short User Name: The unique user name entered while logging-in to the control box as
explained in User
· Login Time: User logged-in date time
- This field contains value only if the user login to particular sewing machine
· Logout Time: User log-out date time
12
12
24
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- This field contains value only when the user logout of particular sewing machine
· Power On Time: Sewing Machine switched on date time
· Power Off Time: Sewing Machine switched off date time
· Total MotorRunTime [ms]: Each sewing info message contains motor run time of that particular
sewing task
- Total motor run time is a sum of all the motor run time obtained by particular sewing machine
between power On and power Off of the machine in milliseconds
· Seams: Total number of sewing info message received from the control box before the piece
counter message
· Pieces: Total number of pieces
· Service Call Category: Displays the active service call of the respective Machine
- This field contains button to send the service call acknowledge message for the
respective machine
- When the service call is active and is not acknowledged, the alert window is displayed
- The alert window as shown below, disappear once the service call is acknowledged
- This field display 'Active' until the mechanic service the particular machine
· Update Time: Last time the machine status table was updated
· Last Message: Last message received by the com server from the control box
When the sewing machine is switched on the Motor Run Time, Seams and Pieces column is set to
value zero.
Machine Status Tool Bar
Button Description
Refreshes Machine Status data table
Exports Machine Status table to Excel file
Hides the detail view of Machine Status table window
Opens Machine Detail window (Machine Detail ) 25
25
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Opens Machine Status Log window (Machine Status Log )
Opens Service window (Service )
Opens All Active Service Calls window (All Active Service Calls )
Send Service Call Acknowledge message to selected Machine
2.2.2.1.1 Machine Detail
Introduction
Machine Detail form contains the detailed information for the selected sewing machine in the
machine status table. It describes the particular machine data precisely. Each machine in the
machine status table has a detail view. The detail view is based on the machine, user and
production information. If the particular machine has any active service call, the acknowledge can
also be sent from this segment.
Machine Status - Machine Detail
Description
The selected sewing machine ID is displayed in the top field of the Machine Detail window.
Machine Detail window display the following information section for each sewing machine:
- Machine Info
- User Info
- Production Info
26
27
45
26
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
The 'Service Call Active' field in the 'Production Info' region, display whether any service call is
active for the selected machine which provides:
- If service call is active, service call acknowledge message can be sent to the respective
machine by clicking on button
- The text displayed in this field, mentions the priority of the service call received as shown in
Service Call ID
2.2.2.1.2 Machine Status Log
Introduction
Machine status log table is the list of currently generated sewing data by the selected sewing
machine in the machine status table. The sewing information is recorded each time the sewing
info message is received by the com server from the sewing machine control box. This recorded
sewing data is displayed in the Machine Status Log table. The sewing data displayed is with
respect to the selected machine. Maximum of 10 recent records are displayed in the machine
status log table based on the latest update time.
Machine Status - Machine Status Log
Description
· Seam Number: Serial number of the seam
- Seam number increments each time when the sewing info message is received
14
27
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- Seam number is initialized to '0' on every Power On or Power Off of the particular sewing
machine
· Update Time: Date time of the sewing info message received
· Total Sewing Time [ms]: Total time taken for sewing in milliseconds
· Motor Run Time [ms]: Total run time of the motor for each sewing info message in milliseconds
· Stops: Number of Stops during sewing
· Average Speed [rpm]: Average Speed in rpm
· Stop Time [ms]: Stop time in milliseconds
· Stitches: Total number of stitches for whole sewing seam
· Pieces: Total number of pieces
- When the 'Piece Counter Ready' message is received by the com server, the number of pieces
are incremented by one
· Delta Time [ms]: Time between previous seam end and seam start in milliseconds
· Work Ratio [%]: Work ratio of each sewing message is a percentage value, which is calculated as
follows:
- Work Ratio = ((TotalSewingTime - StopTime) / TotalSewingTime * 100)
2.2.2.1.3 Service
Introduction
Service contains various service functionality for the sewing machine. Servicing a sewing machine
means, setting sewing 'parameter data sets' to the operator specific value. The main functionality
present in this form are:
- Get/Set specific 'parameter data sets' of the sewing machine control box
- Get/Set 'parameter data set' files from/to the database
- To set piece counter
- To set service counter
28
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Machine Status - Service
· Single Parameter <= Machine
· Selected Parameter by File <= Machine
· Selected Parameter <= Machine
· All Parameter <= Machine
· Single Parameter => Machine
· Selected Parameter by File => Machine
· All Parameter => Machine
· Parameter File <=> Database
· Set Piece Counter
· Set Service Counter
29
30
30
34
35
37
38
40
43
43
29
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.2.1.3.1 Single Parameter <= Machine
Introduction
This section contains the 'Get Parameter' function for single parameter. Get parameter will read
parameter value from the control box. This form will read a single parameter value from the
selected sewing machine control box.
Service Window – Get Single Parameter From Machine
Description
Gets single parameter value from the selected machine in the Machine Status table. The step by
step procedure to get the parameter value from the control box in this section are as follows:
· Parameter Number: Parameter number for which parameter value must be read from the
control box
Click this Get Parameter button to send get parameter message to the control box. If the
parameter value is received from the control box then the value is displayed in the 'Parameter
Value' field and the message window is displayed as shown below.
30
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
If the selected machine is not switched on then the following error window appears.
If the get parameter value was not successful, then the following error window appears.
2.2.2.1.3.2 Selected Parameter by File <= Machine
Introduction
This section gets the parameter value for the parameters in the specified parameter file from the
control box. And writes the obtained parameter value to the parameter file specified.
31
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Service Window – Get Selected Parameter by File From Machine
Description
This section gets the parameter value for all the parameters in the file selected in the field called
'File with list of selected parameter'. This selected parameter file acts an input file and the
parameters from this input file are send to the control box. The received parameter value from
the control box is saved to the file selected in the field called 'Save parameter file to'. This
selected parameter file acts as an output file, where the received parameter value from the
control box is saved into this output file. The step by step procedure to get the parameter value
from the control box in this section are as follows:
· File with list of selected parameter: Select a '.par' file which has a list of all parameters to get
the parameter value from the sewing machine control box by clicking on this button
· Save parameter file to: Click this button which opens a dialog box as shown in Save
Parameter File , to select or create new parameter file (.par file)
Once this button is clicked, this opens the 'Sewing Machine Setup Action' window as shown
below.
· 'Sewing Machine Setup Action' window displays the details regarding which process is going on
for which particular machine and the progress bar ensures the progress of the get parameter
The process of get parameter can be canceled by clicking the cancel button. If the selected
machine is not connected, an error message is displayed as shown below.
44
32
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
If the setup action window closes without any error window then the parameter value is saved to
the file selected in this 'Save parameter file to' field.
2.2.2.1.3.3 Selected Parameter <= Machine
Introduction
This section contains get parameter function for a range of parameter numbers specified.
Parameter value for the particular range of parameter number can be obtained. The received
parameter value is saved in the user selected parameter file.
Service Window – Get Selected Parameter by File From Machine
Description
This section gets parameter values for the set of parameter numbers mentioned in the 'From'
field to 'To' field. The received parameter values are saved to the file selected in the field 'Save
parameter file to'. The step by step procedure to get the parameter value from the control box in
this section are as follows:
· From: Starting number of the get parameter range
33
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
· To: Ending number of the get parameter range, must be greater than the parameter number
entered in the 'From' field
- If the parameter number entered in the field 'To' is greater than the parameter number
entered in the 'From' field, the following error window is displayed by the software
· Save parameter file to: Click button which opens a file dialog as shown in SaveParameter File , to select parameter file (.par file) to save received parameter value
Click 'Get Parameter' button, this opens the 'Sewing Machine Setup Action' window as
shown below.
'Sewing Machine Setup Action' window displays the detail of which process is going on for which
particular machine. The progress bar ensures the progress of the get parameter. The process can
be canceled by clicking cancel button to stop sending the get parameter message. If the selected
machine is not connected, an error message is displayed as shown below.
If the setup action window closes without any error window then the get parameter is successful
and the parameter value is saved in the selected file.
44
34
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.2.1.3.4 All Parameter <= Machine
Introduction
The complete parameter value for the parameters present in the selected sewing machine is
obtained in this form. The user must select only the output file to save the received parameter
value from the sewing machine control box. The received parameter file can be viewed in the
notepad program.
Service Window - Get All Parameter From Machine
Description
The complete parameter value from the control box is received to the selected parameter file in
the field 'Save parameter dump to file'. The step by step procedure to get the parameter value
from the control box in this section are as follows:
· Save parameter dump to file: Click this button which opens a dialog box as shown in Save
Parameter File , to select or create new parameter file (.par file)
When clicked this 'Get Parameter Dump' button, the below Setup Action Window is opened.
44
35
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
The above 'Sewing Machine Setup Action' window displays the detail of undergoing process for
which particular sewing machine. The processing takes place until the complete parameter dump
is received from the selected machine. The below result window displayed at the end of the
process, shows whether the get parameter dump was successfully or not.
If the selected machine is not connected then the below error window is displayed.
Once the process is complete, the received parameter value stored in the parameter dump file
can be viewed in the notepad by clicking button. This button is enabled only when the
parameter dump value is successfully saved to the file.
2.2.2.1.3.5 Single Parameter => Machine
Introduction
This section contains the 'Set Parameter' function for single parameter. Set parameter message
will write the parameter value of the particular parameter to the control box.
36
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Service Window - Set Single Parameter to Machine
Description
This section will set a single parameter value to the selected control box. The step by step
procedure to set the parameter value to the control box in this section are as follows:
· Parameter Number: Enter the parameter number for which the value must be set
· Parameter Value: Enter parameter value for the respective parameter number
Click 'Set Parameter' button to send set parameter message to the selected machine control
box. A dialog box is displayed, showing the result of the set parameter operation, whether it was
successful or not as shown below.
37
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
If the connection from the com server to the sewing machine control box is not established then
the below error window is displayed.
2.2.2.1.3.6 Selected Parameter by File => Machine
Introduction
This section contains a function to set selected parameter from file to the particular machine. Sets
parameter value for all the parameters in the selected file to the selected sewing machine.
Service Window - Set Selected Parameter by File to Machine
Description
Sets parameter value for all the parameters in the file selected in the field 'File with list of all
parameter' to the selected sewing machine control box. The step by step procedure to set the
parameter value to the control box in this section are as follows:
· File with list of all parameter: Select a ".par" file which has a list of selected parameters and it's
respective values by clicking on this button
Click this 'Set Parameter' button, this will open the Setup Action window as shown below.
38
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
The above 'Sewing Machine Setup Action' window displays the detail of undergoing process for
which particular sewing machine and the progress bar display the status of the on going set
parameter process. If the selected machine is not connected, an error message is displayed as
shown below.
If the setup action window closes without any error window then the set parameter process is
successful by setting the value to the selected sewing machine.
2.2.2.1.3.7 All Parameter => Machine
Introduction
This section contains the function to set all parameters from file to the selected sewing machine.
Service Window - Set Selected Parameter by File to Machine
39
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Description
Sets parameter value for all the parameters in the file selected in the field 'File with list of all
parameter' to the selected sewing machine control box. The set parameter dump message is sent
for the collection of parameters in the selected file.
· File with list of all parameter: Select a ".par" file which has a list of all parameters and it's
respective values by clicking on this button
Click this 'Set Parameter Dump' button which open the Setup Action window as shown
below.
The processing takes place until the complete set parameter dump is set to the selected machine.
The below result window is displayed at the end of the set parameter process, which confirms
whether all the parameter value was successfully set or not.
If the selected machine is not connected, an error window is displayed as shown below.
40
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.2.1.3.8 Parameter File <=> Database
Introduction
This section contains functions for writing and reading parameter file to or from the database
respectively. The two main functions are:
· New parameter file can be inserted into the database
· Can fetch parameter file data from the database
Service Window - Get or Set Parameter File to Database
Description
The (.par) parameter file can be saved to the database or can get the (.par) parameter file from
the database from this particular section.
· Copy File from Database to: Click this button to select or create new parameter file (.par
file) or else just copy the file path along with the file name to the text box as shown in the
above window
- When Clicked on this button a dialog box is opened as shown in Save Parameter File
Click this 'Copy Parameter File from Database' button, which display the window as shown
below.
44
41
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Get Sewing Machine ParamFile from DB Window
Select the parameter file as shown in 'Get Sewing Machine ParamFile from DB Window' from the
list and click on this button. Or else double click on the parameter file name to get the file
data from the database to the file selected in this 'Copy File from Database to' field. Once this
button is clicked, the 'Get Sewing Machine ParamFile from DB' window is closed and the file
data from the selected file in DB is written to the local file selected.
· Copy Parameter File to Database: Select a parameter (.par) file which must be saved into the
database by clicking on this button
Click 'Copy Parameter File to database' button, which display the window as shown below.
42
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Update Sewing Machine Parameter File to DB Window
The 'Update Sewing Machine Parameter File to DB' window opens the list of all the parameter
files stored in the database with the 'File Name' and 'Description' column in the first half section
of the window. In the second half section of 'Update Sewing Machine Parameter File to DB'
window contains two tabs namely:
· The First tab always reads the file data of the selected file from the parameter file list
· The second tab always reads the data from the file selected in the field 'Copy Parameter File
to Database'
If the file name selected locally by the user already exists in the database, the software opens
'Update Sewing Machine Parameter File to DB' window pointing to that row in the parameter file
list. Save button is clicked to save the file to the database.
Button Description
Refreshes the list of parameter file table
43
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Reverts any unsaved changes made to the table
Saves changes made to the list of parameter files to the database
Exports Sewing Machine Parameter File table to Excel file
2.2.2.1.3.9 Set Piece Counter
Introduction
This section contains the set piece counter function. Set piece counter for the selected sewing
machine from the machine status table.
Service Window - Set Piece Counter
Description
Set piece counter for selected sewing machine based on the specified trimming count.
· Trimming Count: Enter desired trimming count value
Click 'Set Piece Counter' button to set the value to the selected sewing machine.
2.2.2.1.3.10 Set Service Counter
Introduction
This section contains the set service counter function. Setup service counter for the selected
sewing machine from the machine status table.
44
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Service Window - Set Service Counter
Description
Set service counter for the selected sewing machine by assigning the values in the field and click
'Set Service Counter' button.
· Counter/Timer ID: It is possible to setup 5 service count down value
· Counter/Timer Mode: Counter means stitch counter value
· Start Value: If the the mode is 'Timer' then the start value is in hours
- If value = 0, the counter or timer is deactivated
2.2.2.1.3.11 Save Parameter File
The window as shown below is the file dialog, which permits the user to select the existing
parameter file or to create a new empty parameter file. The step by step procedure to select
parameter file are as follows:
· Select an existing .par file or just type a new parameter file name in the 'File name' field and
click Open button
45
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
· Example: Select 'paramdump.par' file in the file dialog to overwrite the data in the existing file
by the new parameter values and click on Open button
· Or else type any new file name example 'dump' in the field 'File name' and click on Open
button
- Example: New parameter file called 'dump.par' will be created and the received value from
the control box will be saved to this file
Save Parameter File Dialog Box
2.2.2.1.4 All Active Service Calls
Introduction
All active service call table is the list of active service calls for all the sewing machines in the
machine status table. Active service calls are the service calls which are waiting for the service by
a mechanic. All these active service calls from all the connected sewing machines are displayed in
this table.
46
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Machine Status - All Active Service Calls
Description
All Active Service Calls window display if there is any active service call present in any machines
of Machine Status table. The data in this table specifies the particular machine data and the
service call details. The following are the column description of the all active service calls table:
· Machine ID: ID of the machine which received service call
· Service Call Category, Source, Operator Name, Service Call ID, Event : Describes the service call
functionality (Service Call ID )
· Update Time: Time when the service call was received
· Acknowledge Time: Time when service call acknowledge message is sent
Once the particular machine is serviced by a mechanic, the respective machine data entry in 'All
Active Service Calls' table is removed.
2.2.2.2 Statistic
Introduction
Statistic table is the list of statistic data based on user or machine. The performance efficiency
based on user and machine can be analyzed in this table. The data entry of this table is based on
the sewing information received during the course of time. Based on the time interval selected
the statistics data can be reviewed. The records to be viewed can be limited to the desired value
count. Determines the total and the average data value of the particular user or machine
selected.
14
47
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Production - Statistic Form
Description
The detailed description of the form are as follows:
Selection
Select 'User' or 'Machine' based on which the statistics data must be viewed.
· User: Select the individual user name from the combo box or select '%' to view all the user
statistics data
· Machine: Select the individual machine ID from the combo box or select '%' to view all the
machine statistics data
· From date: Start date of the data to be viewed
· To date: End date of the data to be viewed
· max. records in the table: Mention total number of records to be viewed in the table
- In this table, the maximum of 2000 records can be viewed
Once all the above data are entered, click refresh button to view the data based on the
requirements entered.
Results
· The 'Results' section displays the total and the average value of the sewing data, based on the
selection
- Total number of seams, stops, stitches and pieces: Sum of respective column values
48
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- Average of 'Motor Run Time', 'Average Speed' and 'Work Ratio': Average value obtained from
the respective column values
- Total downtime: Calculated based on the customer requirements
The table column values are explained in Machine Status Log .
Image Description
Refreshes Statistic data table
Exports Statistic table to Excel file
Gets previous sewing records based on maximum records in table and timeinterval
Gets next sewing records based on maximum records in table and timeinterval
2.2.2.3 Service Call Log
Introduction
Service call log table is the list of all service calls generated by/for the list of sewing machines in
the machine status table. This table gives a detail information of the machine, service call and its
servicing. Same machine may have received one or more service calls, which is listed in this table.
This table contains all the service calls whether if it is currently active or not. The service call
event is filtered with respect to user or machine based on the time interval selected and the
maximum records.
Production - Service Call Log Form
Description
The detailed description of the form are as follows:
Selection
26
49
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Select 'User' or 'Machine' based on which the statistics data must be viewed.
· User: Select the individual user name from the combo box or select '%' to view all the user
statistics data
· Machine: Select the individual machine ID from the combo box or select '%' to view all the
machine statistics data
· From date: Start date of the data to be viewed
· To date: End date of the data to be viewed
· max. records in the table: Mention total number of records to be viewed in the table
- In this table, the maximum of 2000 records can be viewed
· Source: Select whether the source must be an 'Operator' or 'Mechanic' or '%' to view both data
Once all the above data are entered, click refresh button to view the data based on the
requirements entered
· Operator Name: User name while service call was received
· Update Time: Time when service call was received
· Message Buffer ID: Internal message ID, which is unique for each message
· Source, Service Call ID, Event, Service Call Category : Described in Service Call ID
· Acknowledge Time: Time when service call is acknowledged
· Mechanic Name: Name of the mechanic for servicing that particular machine
- If the field is empty then the mechanic has not logged-in to that particular machine for
servicing
· Service Time: Calculated based on the customer requirements [Seconds]
- This field value is 0 if the service call is active
- Service time is calculated as: Service time = (MechanicLogoutTime - MechanicLoginTime)
· Machine ID: ID of the sewing machine
Image Description
Refreshes Service call log data table
Exports Service call log table to Excel file
Gets previous service call records based on maximum records in table andtime interval
Gets next service call records based on maximum records in table and timeinterval
14
50
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.3 Settings
Introduction
This section provides the operator to modify the frontend application to the desired
requirements. The modified operations can be saved for the further usage. The frontend
application text can be changed based on the language options provided. Server setup can be
made based on the required specifications. Data backup can be made automatically during the
course of time.
Setting Section
Description
Settings section contain three parts
· Skins: User can select the look and feel of the frontend application window by selecting
anyone of the options in this section
· Window Configuration
51
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- Open Window Configuration: Loads the selected configuration file to the frontend and
saved as a default configuration. 'Open Window Configuration' button will open the
window with list of saved configuration files as shown below. The saved configuration file
are in '.layout.xml' format in the base directory (frontend application startup path) of the
frontend application. Operator can select the configuration file and click Ok button. The
selected configuration is applied for the frontend application when Ok button is clicked
and saved as default configuration of the frontend.
Select Window
- Save Window Configuration: Saves the current configuration of the frontend as a default
config file and writes the configuration to the new config file or overwrites the selected
config file. This form saves the window configuration in '.layout.xml' file format in the
base directory (frontend application startup path) of the frontend application. 'Save
Window Configuration' button will open the window as shown below. Provide the
configuration file name in the field (example: 'VisualStudioBlue') as shown below to save
the configuration into new file and click OK button. Or else click button which
provides the list of saved configuration file names, select file name to which the current
configurations must be overwritten and click Ok button. The configuration is saved as a
default configuration of the frontend application.
Save Window Configuration Window
- Delete Window Configuration: Deletes the window configuration file from the base
directory. 'Delete Window Configuration' button will open the list of configuration file
window as shown below. Select the configuration file name from the list and click Ok
button.
Delete Window Configuration Window
· Setup: Contains all the setting property of the frontend application as described in Setup
2.2.3.1 Window Configuration
Enter topic text here.
52
52
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.3.2 Setup
Setup section contains formulas of the following:
· Language Setup
· Communication Server Setup
· Frontend Server Setup
· House Keeping
2.2.3.2.1 Language Setup
Introduction
The frontend application text can be switched to the desired language provided. This form
provides the multiple language options to choose. The selected language is saved as a default
language of the frontend application.
Description
The complete form text can be changed based on the selected language in the combo box.
· Select Language: Select language from the given option
· Set language of the frontend form based on the selection
· Refresh the language files when the language files are modified
Once the language is selected, click Set language button to switch to the selected language.
Setting - Language Setup Form
2.2.3.2.2 Communication Server Setup
Introduction
Communication server setup is the list of com servers initialized. Com server application insert
this table entry when the com server application is initialized with the new 'Server IP Address'.
This server ip address of the com server is inserted as a server id. The frontend operator can add,
delete or modify the data entry into this table.
53
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Description
The detail information of the communication server is listed in this table. The data values in this
table can be edited or a new row entry can be inserted. The columns description are as follows:
· Server ID: IP Address of the communication server application, for the case if two servers
running on same system
· Computer Name: Name of the computer in which the communication server application is
initialized
· Description: Description for the particular row entry, initially it is described as 'NEW RECORD'
when the new entry is added to the table
· Com Server API Port: Port number of the communication server application through which the
frontend application is connected
Setting - Communication Server Setup Form
Button Description
Refreshes the communication server setup data tableReverts any unsaved changes made to the table
Saves the changes made in the table to the database
2.2.3.2.3 Frontend Server Setup
Introduction
The frontend application is connected to the following:
· Database: To extract data and display in it in the frontend application tables
· Com server application: To communicate with the sewing machine control box
This form provides access to modify both database and the com server connection configuration
of the frontend application.
54
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
Setting - Frontend Server Setup Form
Description
The Frontend Server Setup is used to set the database and com server connection configuration of
the frontend application. The list of three configurations are provided, so that the frontend
operator can modify each list entry and use it. The modified configurations can be changed and
must restart the frontend application to apply the changes. The first section of the window
display the current configurations that the frontend is running on. The second section contains
the three main configurations of the frontend application that can be modified.
· DB Server Host: Database server host name or IP address to which the frontend application
must be connected
· Com Server API Port: The communication server port on which the communication server is
running
- Enter the com server port to which the frontend application must be connected
· Com Server API Host: The communication server host name or IP address to which the frontend
application must be connected
Click on the test button to check the connection to the host, if the test is successful the result
window is displayed as below.
55
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
If the Test failed the result window is displayed as below.
The list of three entries with DBHost, ComServerPort and ComServerHost are displayed in the list
box of Frontend Server Setup window. The fields are updated based on the list selected. Click on
any one of the list, this selected list value is displayed in the respective fields. Operator can edit
these fields and save the changes. When the 'Change' button is clicked, the selected list value is
changed based on the respective field. Once 'Apply' button is clicked, the default configuration of
the frontend application is changed to the respective values and the following information
window is displayed.
Restarting the frontend application is a must, to implement the new configurations applied. Click
on 'Restart' button to restart the frontend application. The frontend application will restart with
new configurations entered.
Button Description
Test Test the connection to the respective host
Change Selected list value is modified based on the entered value in the field
ApplySet the default configuration of the frontend Saves the respective value to the selected list
Restart Restart the frontend application
56
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
2.2.3.2.4 House Keeping
Introduction
This form provides the operator to manage the data backup and cleanup of the database during
the prescribed time interval. Handles the data backup of the complete production data. The
backup is done automatically by the com server application in the background. Data backup is
executed on the scheduled backup date time. Archive data table is the list of all the old archived
data (Backup data). This archived data can be loaded into the frontend application for reference.
Setting - House Keeping Form
Description
House Keeping has two main functionality as follows:
· Helps to modify the database backup configuration
· Permits the frontend operator to change the database of the frontend application from the
production database (current working database) to the archive database
The first section of the House keeping are the current data backup setting as shown below:
First section of the House Keeping Form
57
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
The above backup setting values in the table can be modified in the fields as shown below:
First section of the House Keeping Form
· MySql Tool Path: Specify the tool path where the program 'sql.exe' and 'sqldump.exe' are
located in the system
· Backup Location Path: Create a backup directory, where the backup data files must be stored
- Copy this directory path to this field
· Backup Time: Backup time, when the backup will be executed
- Enter the desired backup time in this field
· Backup Interval: The time interval when the backup will be executed
- Select the backup interval from the list of values from the field, which are as follows
o Deactivate: Data backup will not be executed
o Daily: Data backup will be executed every day on the selected backup time
o Weekly: Data backup will be executed every week of the selected week day on theselected time
o Monthly: Data backup will be executed every first day of the month on the selected backuptime
· Week Day For Weekly Backup: Select the day of the week for the data backup when theselected Backup Interval is 'Weekly'
· Next Scheduled Backup Date: Specifies the backup time interval based on the selection made inthe 'Backup Time', 'Backup Interval' and 'Week Day For Weekly Backup' field
- The value of this field can be modified individually for any desired date time of the databackup
· Delete detailed sewing recorded data after X-days: Specify that the sewing records older than Xdays are deleted from the production database after the execution of a database backup
- If this field value is 0 then no sewing records are deleted from the database
58
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
· Last Executed Backup Date (Read Only): Date and time of the last executed backup
· Last Executed Backup Status (Read Only): Status of the last executed data backup
- It can have SUCCESS or ERROR as a status
· Last Executed Backup Info (Read Only): Information regarding the last backup execution
Image Description
Refreshes all the data backup fields Reverts any unsaved changes made to the table fields
Saves the changes made in the data backup fields to the database
Opens or loads Archive Database to the frontend applicationCloses all the opened tabs in the frontend application
Opens or loads Production Database to the frontend applicationCloses all the opened tabs in the frontend application
2.2.3.2.4.1 Archive Data
Introduction
Archive data table is the list of all the information of the backup data (archive data) folders. The
executed data backups are saved in the backup folders locally. This backup folders contain
production data which can be loaded into the frontend application. Backup folders can be
removed permanently from the local directory and from the database by the frontend operator.
Description
List of all the backup data folders are listed in the Archive Data table as shown below:
Second section of the House Keeping Form
· Archive Path: Backup location or folder name where the backup files are stored which is
specified by the first section of the House Keeping From in 'backuplocationpath' field
· Archive Execution Date: The date and time of the backup execution
· Backup Location Path: Backup directory path, where the backup folders are present
· Load Request Pending: Set by the frontend application if the archive shall be loaded; reset if
archive is loaded or load failed
59
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- The status of this field specifies whether the loading of archive data is in progress or not
o Idle: Archive load data is not in progress
o In Progress: Archive load data is in progress
· Delete Request Pending: Set by frontend application if the archive shall be deleted
- This will remove the archive folder from the local directory and also from the database table
- Once the archive is deleted, particular data entry is removed from this archive table
- The status of this field specifies whether the deleting of archive data folder is in progress or
not
o Idle: Delete archive data folder is not in progress
o In Progress: Delete archive data folder is in progress
· Archive Begin DateTime: Date time of the first record based on the update time of the message
in that particular backup data folder
· Archive End DateTime: Date time of the last record based on the update time of the message in
that particular backup data folder
· Load: Loads the specific archive data into the frontend application
· Delete: Deletes the specific archive data folder from the database and also from the local
system backup directory
Step by step procedure to load or delete archive data
· To view the particular archive data in the frontend application, click 'Load' button on the
particular archive folder row
· As soon as 'Load' button is clicked the status of the 'Load Request Pending' field switches
from status 'Idle' to 'In Progress'
· Loading of the archive data takes a while
· Click refresh button to check the status of 'Load Request Pending' field
- If the status has changed to 'Idle' then the archive database has been loaded or else wait for
some more time and click refresh button to check the status
· Once the data is loaded into archive database, click 'Open Archiv data' button to view the
archive data in the frontend application
60
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
- If the archive data has been loaded into frontend application, the user can only view this
particular data but cannot edit any data values
· Click 'Open Production Data' button to return back to the current production database
· Click 'Delete' button to delete the archive data folder from both database and from the
backup location path
· As soon as 'Delete' button is clicked 'Delete Request Pending' field changes the status from
'Idle' to 'In Progress'
· Click 'Refresh' button to check if the status of 'Delete Request Pending' field changed back
to 'Idle'
- If the status is changed to 'Idle' then the backup folder is deleted or else wait for sometime
and click refresh button to check the status
2.2.3.2.5 Touch Mode Setup
Introduction
Frontend application also works on the touch-screen device. This form the touch mode feature to
access the frontend application on a touch screen device. User can turn On or Off the touch mode
of the frontend application in this particular form. Turning On the touch mode feature enables
the frontend to create more space between the controls and the buttons get enlarged, so that the
commands are easier to tap.
Setting - Touch Mode Setup Form
Description
Clicking on this button on the frontend Settings tool bar opens the form as shown above.
This form contains the switch to On or Off the touch mode of the frontend application. Initial
state of the switch defines the current state of the frontend application, whether the application
is in touch mode or not. If touch mode is On, then the frontend application is in touch mode. If
touch mode is Off, then the frontend application is not in touch mode. When the state of the
61
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Biasys I4 Frontend
switch is changed, it closes all the currently opened tabs or forms in the frontend application to
apply the touch mode changes to the application.
EFKA Communication Server
63
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
EFKA Communication Server
3 EFKA Communication Server
Introduction
Efka communication server is a server application which establish a connection to one or more
sewing machine client control box. The connection established to each client control box is a TCP
IP connection. The main purpose of the connection is to record the data communication between
the client control boxes and the Efka communication server software. The data communication
between the com server application and the client control boxes are saved in the database. The
data backup is executed by the com server application in the background on the particular time
scheduled. The application process is logged, based on the configurations selected during the
start of the com server software.
3.1 Efka Communication Server Login
Introduction
Login window is displayed on the start of the com server application. Login is necessary to gain
access by the operator for the com server application. The login window must be entered with
the values appropriate to the data field as shown below. If login fails, the server application
cannot be initialized.
64
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
EFKA Communication Server
Efka Communication Server Login
Description
· Database Account Name: Name of the valid database user account
· Database Password: Password for the respective user account if existing
· Database Host: Valid database server host address which contains the entered user account and
valid data
· Server IP Address: IP Address of the server to start
· Test (Button): Is used to test the entered server IP address is valid or not
· Port Number: Communication server port number
· Extended Data Record Directory: Provide the local directory name, to save the message buffer
to the database file
- Sewing machine data obtained from the client control box are stored in the '.db' database
file
65
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
EFKA Communication Server
· Enable Extended Data Recording (CheckBox): Select this field if the data must be saved to
message buffer or else deselect this field
· Specify Application Logging: The complete software processing can be logged based on this
selection
- Application logging information can be selected during the login between the following
options
o Log All
o Only Errors
o Errors and Log Infos
o No Logging
· Login (Button): Performs application login operation
- If login successful the communication server application(Efka ComServer Application ) is
opened
- If login fails the error message is displayed
· Cancel (Button): Exist the complete application
3.2 Efka Com Server Application
Introduction
The communication server application will be accessible when the login is successful. Click start
button to start the com server application.
Efka Com Server Application Window
65
Log From DB
67
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Log From DB
4 Log From DB
Introduction
This form is used to read the data from the selected 'MessageBuffer_Date.db' database file. The
data communication between sewing machine control box and com server application are stored
in the database (.db) file. The default directory of this 'MessageBuffer.db' file is selected by the
com server operator during the start of the com server application.
Log From DB Form
Description
· Misc: Select a ".db" file to be read which is located in the local folder by clicking on
button
- The directory of this database file is selected in the com server application in field
'Extended Data Record Directory'
Search Data: Specifies the search criteria to sort the message buffer data accordingly. Select one
of the following main search category:
- Newest Log Messages: Filters only the recently added records based on the 'Max. No Of
Records'
63
68
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Log From DB
- From Date/Time: Filters the data from the date time specified in this field, based on the
'Max. No Of Records'
- From ID: Filters the data from the ID (First Column of the table, Message Buffer ID) which
is unique for each row in the table, based on the 'Max. No Of Records'
Select any of the following sub search category based on the table columns
- Machine ID
- RFID
- Message ID
- User Name
- Only Status 'Not OK': Select this field to filter the message with the status 'NOK'
· Max. No Of Records: Specify the maximum record count to view in the table
Click 'Refresh' button each time if the search categories are modified. These buttons
as shown in the above window are used to get previous or next set of
maximum records in the table. The button is used to display or hide the date
column in the log data table.
The second table to the right of the log data table is the detail table of the Message column, It
explains the message column with the detail Name, Value and Description.
Example: The below window displays the detail of the 'Power ON' message
Log Viewer
70
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Log Viewer
5 Log Viewer
Introduction
This form is used to view the complete log data based on the application. Data logging is a process
of storing data over a period of time in order to analyze application mechanism during the
application information or errors. The logging mechanism is implemented for 'communication
server', 'frontend' and 'log from DB' applications. The data logging option can be chosen based on
the user requirements during the start of the both communication server and frontend
application.
Log From DB Form
Description
Log data from the specified file path is read into this form. The data displayed in the above form is
the application information followed by icon and application error followed by
icon.
· Path: Select the root log directory of the log files
- Click button which opens the window as shown below
71
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Log Viewer
- Provide desired name in the field 'Alias'
- Provide the directory path where all the log files are stored as show below
- Click 'OK' button once the valid data entered in the field
· Program: Select program name to view the log data only from the selected program
- Or else select 'All Programs' to view the log data for all the program
- The current program names present in the log application are
o ComServer: Log data from the Com server application will be displayed
o GlobalDef: Log data from the database program will be displayed
o logFromDB: Log data from the 'Log From DB' application will be displayed
o FrontEnd: Log data from the frontend application will be displayed
· Timespan: Select the date to view the log data during the particular time interval
Gets the previous log records based on the timespan specified
Gets the next log records based on the timespan specified
· Refresh (F5): Click refresh button to view the log data based on the selected criteria
- Click refresh button each time the criteria is changed
· Choose File (Button): Click choose file button to select log collection (.LogCol) files to read
data from this particular file to the log viewer
· Filter
- Category: Filter based on the category name, select category in the combo box and click
filter button
o Each 'Program' name has unique categories
72
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Log Viewer
- Message: Filter based on the alphabets, particular text or complete message and click
- Error: Select the filter button to filter only error messages
- Deselect the filter button in the Error field to view all log messages
· Save To File: Save the log messages
- Select: Save the selected messages to the log collection (.LogCol) file
- All Shown: Save all the messages shown in the log viewer to the log collection (.LogCol)
file
· Click 'F2' button on the keyboard to make the log viewer application to display as a topmost
application
· Click 'F3' which enables both automatic refresh and the application points to the newest log
entry received
· Click 'F4' which only points to the newest log entry received
Database
74
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
6 Database
Introduction
Data communication between client control box and com server application is stored in the
MySQL database.
· The EFKA Industry 4.0 Software Solution database schema are as follows
- i4_management: Collection of data tables containing primary data of the sewing machine and
the sewing machine user
- i4_management_archiv: Archive database of the i4_management database. The data tables in
this schema are same as 'i4_management'
- i4_production: Collection of data tables containing production data of all the sewing
machines connected to the com server application
- i4_production_archiv: Archive database of the i4_production database. The data tables in this
schema are same as 'i4_production'
Remark: Do not change the database schema.
6.1 i4_management
Introduction
Collection of data tables containing primary data of the sewing machine and the sewing machine
user. The i4_management schema contains data tables as shown below in the diagram.
75
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
Collection of data tables in i4_management schema
6.1.1 User - Table
1. user
This table contains data regarding sewing machine user. Data entry to this data table is done by
the system administrator before the user can login. User table has two foreign keys, namely:
76
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
· EfkaUserGroupID (Foreign-Key): Referenced from 'efkausergroup' data table
· InterUserGroupID (Foreign-Key): Referenced from 'internalusergroup' data table
Columns:
· UserGUID (Primary-Key): Unique value for each user data entry in the table
· RealUserName: Full name of the user
· ShortUserName (Unique): Short name of the user
- Main purpose of this field is to distinguish between the user who has the same full name
in 'RealUserName' field
- All the values in this column must be distinct (Unique)
· RFID: Unique ID value from the RFID chip or the value entered in the Efka variocontrol during
user login
· EfkaUserGroupID (Not Null): Efka user group ID value, either 1 or 2
- It is a foreign key related to 'efkausergroup' datatable
- The value cannot be null
· InternalUserGroupID (Not Null): Internal user group ID value which can be either 1 or 2 or 3
- It is a foreign key related to 'internalusergroup' datatable
- The value cannot be null
· Description: Description for the particular row entry
· Spare: Spare column from 1-5 are the extra columns which can be used in future if necessary
2. internalusergroup
This table contains detail data of the internal user. Currently this table data is not used by the Efka
I4 solution software.
Remark: Do not change any data in this data table.
Columns:
· InternalUserGroupID (Primary-Key): Unique internal user ID
· InternalUserGroupName: Name of the internal user
· The data in this table is as follows:
77
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
InternalUserGroupID InternalUserGroupName
1 Admin
2 Developer
3 User
3. efkausergroup
This table contains efka user data.
Remark: Do not change any data in this data table.
Columns:
· EfkaUserGroupID (Primary-Key): Unique efka user ID
· EfkaUserGroupName: Name of the efka user category
· The data in this table is as follows:
EfkaUserGroupID EfkaUserGroupName
1 Mechanic
2 Operator
6.1.2 Machine - Table
4. machine
This table is the list of sewing machines connected to the com server application. Contains
detailed information regarding sewing machine client control boxes connected to the com server
application. The data in this table is entered by the com server application when the new control
box is connected to the com server application.
Columns:
· MachineGUID (Primary-Key): Unique value for each machine data table entry
· MachineID: Sewing machine ID
· ServerID (Foreign-Key): IP address of the com server application, to which the sewing machine
control box is connected
- Foreign key referenced from 'communicationserver' data table
78
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
· CircuitBoardNo: Sewing machine circuit board number
· SerialNo: Efka control box serial number
· IPAddress: IP Address of the sewing machine control box connected to the com server
application
· Description: Description for the particular row entry
· Spare: Spare column from 1-5 are the extra columns which can be used in future if necessary
5. communicationserver
This table is a list of com server applications initialized.
Columns:
· ServerID (Primary-Key): IP Address of the communication server application, for the case if
two servers running on the same system
· ComServerAPIPort: Port number of the communication server application through which the
frontend application is connected
· ComputerName: Name of the computer in which the communication server application is
initialized
· FillMessageBuffer: Condition to fill the message buffer with the data communication
between client and server
- Value = 0 (Message buffer is not filled by the com server application)
- Value = 1 (Message buffer is filled by the com server application)
· Description: Description for the particular row entry
6. sewingmachinegroup
This table is a list of sewing machine group, created in the frontend application. Each sewing
machine group can contains a list of sewing machines.
Columns:
· GroupGUID (Primary-Key): The unique value for each group entry
· GroupName: Name of the sewing machine group
· Description: Description for the particular row entry
79
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
7. machine_sewingmachinegroup
Contains the list of sewing machines inserted into any sewing machine group.
Columns:
· GroupGUID (Primary-Key) (Foreign-Key): Referenced from the 'sewingmachinegroup' table
· MachineGUID (Primary-Key) (Foreign-Key): Referenced from the 'machine' table
· FileName (Foreign-Key): Referenced from the 'sewingmachineparameterfile' table
8. qrymachineofgroup
'qrymachineofgroup' is a database view which is defined from the 'machine' and the
'machine_sewingmachinegroup' table. A view is a virtual table that contains no physical data but
provides an alternative way to look at the data.
The view is created where the 'MachineGUID' of 'machine_sewingmachinegroup' and 'machine'
table are equal. It contains a list of sewing machine clients connected to the com server. It gives a
detail view of the machines in the particular sewing machine group.
9. sewingmachineparameterfile
Contains the list of parameter files. The data in this table can be modified by the frontend
application.
Columns:
· FileName (Primary-Key): Name of the parameter file
· FileData: Parameter file data
· Description: Description for the particular row entry
6.1.3 Other - Table
10.parameter
Contains the list of parameter value, which is referenced by the com server application.
Remark: Do not change any data in this data table.
Columns:
· ParameterName (Primary-Key): Name of the parameter
80
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
· ParameterValue: Value of the parameter
11.servicecallid
Contains the list of detailed information of all the service calls that can be generated.
Columns:
· ServiceCallID (Primary-Key): Each service call event is identified by this unique ID
· Event: Each respective ID has a event
· Source: Specifies the owner of the service call who can sent the particular service call event
· Category: Specifies the priority level of each service call event
- 3: High Priority
- 2: Middle Priority
- 1: Low Priority
12.lasterrorid
Contains the list of error messages sent from the sewing machine control box to the com server.
Remark: Do not change any data in this data table.
Columns:
· ErrorID (Primary-Key): Unique ID of the error list
· Error: Error name
13.hk_backup
Contains data configuration regarding regular database backup and cleanup tasks.
Columns:
· hk_backupGUID (Primary-Key): Unique value for each data row entry
· backuplocationpath: Path where the backups are stored on the server
· backuptime: The time when the backup shall be executed
- Specified as DateTime, but only the time part is evaluated. e.g. 23:00, the time when the
production is not active
81
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
· mySqlToolsPath: The path where the program 'sql.exe' and 'sqldump.exe' are located
· lastExecutedBackupDate: Date and time when the backup was executed the last time.
· backupInterval: This is an enumeration:
- backup deactivated = 0
- daily = 1
- weekly = 2
- monthly = 3
· lastExecutedBackupStatus: Its an enumeration
- 0 = NONE
- 1 = SUCCESS
- 2 = ERROR
· weekDayForWeeklyBackup: The weekday as set for the current culture information
· scheduledBackupDate: Date time when the data back is scheduled to be executed
· lastExecutedBackupInfo: Date and time of the last executed data backup
· CleanUpSewingRecordsOlderThanXdays: Sewing records older than X days are deleted from
the production database after the execution of a database backup
- A value of 0 indicates to not delete old records
14.hk_backup_archives
Contains list of all the data backup folders (Archive data Folders).
Columns:
· archiveGUID (Primary-Key): Unique value for each data row entry
· archivePath: Backup location or folder name where the backup files are stored under
'backuplocationpath' folder
· archiveExecutionDate: Date and time of the backup execution
· backuplocationpath: Path where the backups are stored on the server
· loadRequestPending: Set by frontend application if the archive shall be loaded; reset if
archive is loaded or load failed
- Value = 1 (set)
82
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
- Value = 0 (Load action is not in process)
· deleteRequestPending: Set by frontend application if the archive shall be deleted
- Value = 1 (set)
- Value = 0 (Delete action is not process)
· archiveBeginDateTime: Date time of the first record based on the update time of the message
in that particular backup data folder
· archiveEndDateTime: Date time of the last record based on the update time of the message in
that particular backup data folder
6.2 i4_production
Introduction
This section contains production data of all the sewing machines connected to the com server.
The diagram shown below is the collection of data tables in the i4_production database.
83
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
Collection of data tables in i4_production schema
84
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
6.2.1 DailyStatistic - Table
1. dailystatisticuser
This table stores the sewing data statistic for the sewing machine user on a daily basis. The
statistic is computed by the com server application in the background.
Columns:
· UserGUID (Primary-Key): Unique ID created in the user table, refer 'user' table in User
Table
· UpdateTime (Primary-Key): Row updated date
· RealUserName: Full user name of the logged-in user to the sewing machine control box
· ShortUserName: Unique user name of the logged-in user to the sewing machine control box
· TotalPieces: Total number of sewing pieces, , incremented by one when the sewing
information message is received by the com server application
· TotalNoOfSeams: Total number of seams, incremented by one when the 'PieceCounterReady'
message is received by the com server application
· averageMotorRunTime: Average motor run time in milliseconds
· averageSpeed_rpm: Average motor speed in rpm
· AVG_WorkRatio: Average work ratio in percentage
· TotalStops: Total number of stops on that specific day
· TotalStitches: Total number of stitches on that specific day
· TotalDowntime: Total down time on that specific day in seconds
2. dailystatisticmachine
This table stores the sewing data statistic for sewing machines on a daily basis. The statistic is
computed by the com server application in the background.
· MachineGUID (Primary-Key): Unique ID, refer 'machine' table in Machine Table
· UpdateTime (Primary-Key): Row updated date
· All other columns except 'MachineGUID' are similar to 'dailysatisticuser'
75
77
85
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
6.2.2 MachineStatus - Table
3. machinestatus
Contains list of sewing machines connected to the com server. Gives the detail information of the
connected machines.
Columns:
· MachineGUID (Primary-Key): Unique value created in the machine table, refer 'machine' table
in Machine Table
· UpdateTime: Date time of the recently received message
· MessageBufferID: Unique internal message ID value
· MachineID: Machine ID of the connected sewing machine control box
· CircuitBoardNo: Circuit board number of the connected sewing machine control box
· SerialNo: Serial number of the connected sewing machine control box
· IPAddress: IP address of the com server application connected by the sewing machine control
box
· RealUserName: Full user name of the logged-in user to the sewing machine control box
· ShortUserName: Unique user name of the logged-in user to the sewing machine control box
· EfkaUserGroupName: Efka user group name of the logged-in user, whether the user is
Mechanic or Operator
· InternalUserGroupName: Internal user group name of the logged-in user, whether the user is
Admin or Developer or User
· LoginTime: Date time of the user login to the sewing machine control box
· LogoutTime: Date time of the user logout to the sewing machine control box
· PowerOnTime: Date time of the sewing machine control box when switched on
· PowerOffTime: Date time of the sewing machine control box when switched off
· MotorRunTime: Total motor run time of all the motor run time obtained by particular sewing
machine between power On and power Off of the machine [milliseconds]
· Seams: Total number of sewing info message received from the control box before the piece
counter message
· Pieces: Total number of pieces
· Downtime: Time taken by the mechanic to service the sewing machine control box [seconds]
77
86
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
- DownTime = (MechanicLogoutTime - MechanicLoginTime) in seconds
· LastMessage: Last message received by the com server application from the sewing machine
control box
· LastError: Last error message of the particular sewing machine control box
· SoftwareVersion: Software version of the sewing machine control box, received during the
'Power on' or 'Login' or 'Logout' message
· Description: Description of each message communication process
· ServiceCallActive: Specifes if the service call is active or not
- Value = 0 (Not active)
- Value = 1 (Active)
· Status: Specifies the current status of the efka control box as follows,
- PowerON: When com server application receives power on message from the sewing
machine control box
- Login: When com server application receives login message from the sewing machine
control box
- Logout: When com server application receives logout message from the sewing machine
control box
- PowerOff: When com server application receives power off message from the sewing
machine control box
- Disconnected: When com server application receives disconnected message from the
sewing machine control box
· PieceIncremented: Specifies whether the piece counter is incremented or not
- Value = 0 (Not incremented), is set to '0' when 'SewInformation' message is sent by the
sewing machine control box
- Value = 1, Incremented, is set to '1' when 'PieceCounterReady' message is sent by the
sewing machine control box
· ServiceCallCategory: Specifies whether the received service call priority, refer 'servicecallid'
table in Other Table
- If the service call is not active then the ServiceCallCategory value = 0
· ServiceCallID: Specifies the unique service call ID number received by the service call message
- Refer 'servicecallid' table in Other Table
79
79
87
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
- If the service call is not active then the ServiceCallID value = 0
· MachineState: Specifies the status of the machine as following
- 0: Off, If the sewing machine is switched off
- 1: On, If the machine is switched on
- 2: LoggedIn, If the user has logged-in to the specific machine
- 3: Service, If the mechanic has logged-in to the specific machine for servicing the machine
If the user logout of the machine, the 'MachineState' field value will be '1'
Deletion of data entry in this 'machinestatus' table is restricted if there is any child row existing
which is referring to 'MachineGUID' column.
4. machinestatuslog
Contains all the message data received from the control box. Each message sent from the sewing
machine to comserver, is entered as a new entry to this data table.
· MachineGUID (Primary-Key): Unique value created in the machine table, refer 'machine' table
in Machine Table
- Foreign key referenced from 'machinestatus' 'MachineGUID' column
· UpdateTime (Primary-Key): Date time of each message received
· MessageBufferID (Primary-Key): Unique internal message ID value
The combination of above three value must be unique value for each data entry in this table
· The 'MachineGUID' is the foreign key to this 'machinestatuslog' table, referenced from
'machinestatus' 'MachineGUID' column
· The data table columns present in 'machinestatuslog' table is same as 'machinestatus' table
except 'UserGUID' field
- UserGUID: Unique ID created in the user table, refer 'user' table in User Table
- UserGUID value is null
o If the user has not logged-in
o If the logged-in user does not have an entry in the user table
6.2.3 Other - Tables
5. sewinginfolog
77
75
88
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
Contains seam status information of sewing information message. The sewing information is
computed by the com server application when sewing information message is received from the
control box.
Columns:
· MachineGUID (Primary-Key) (Foreign-Key): Unique value created in the machine table, refer
'machine' table Machine Table
- Foreign key referenced from 'machinestatus' 'MachineGUID' column
· UpdateTime (Primary-Key): Date time of the sewing message received
· MessageBufferID (Primary-Key): Unique internal message ID value
The combination of above three value must be unique value for each data entry in this table
· UserGUID: Unique group ID, refer 'user' table User Table
· TotalSewingTime_ms: Time for whole sewing seam in milliseconds
· TotalStitches: Total stitches for whole sewing seam
· AverageSpeed_rpm: Average speed in rpm
· RunTime_ms: Motor run time in milliseconds
· StopTime_ms: Stop time in milliseconds
· DeltaTimePrevSeamEnd2Start_ms: Time between previous seam end and seam start in
milliseconds
· Stops: Number of stops during sewing
· WorkRatio: Work ratio in percentage
- It is calculated as follows
- Work Ratio = ((TotalSewingTime - StopTime) / TotalSewingTime * 100)
6. sewinginfosectionlog
Section status information of sewing information message is inserted into this table. The section
information is computed by the com server application when sewing information message is
received.
Columns:
· MachineGUID (Primary-Key) (Foreign-Key): Unique value created in the machine table, refer
'machine' table in Machine Table
- Foreign key referenced from 'sewinginfolog' 'MachineGUID' column
77
75
77
89
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
· UpdateTime (Primary-Key) (Foreign-Key): Date time of the received sewing information
message
- Foreign key referenced from 'sewinginfolog' 'UpdateTime' column
· SectionNo (Primary-Key): Serial number of each section
· MessageBufferID (Primary-Key): Unique internal message ID value
The combination of above four primary key value will be unique value for each data entry in this
table
· SewingTime_ms: Sewing time for section in milliseconds
· Stitches: Stitches for section
· AverageSpeed_rpm: Average time for section in rpm
· RunTime_ms: Motor run time in milliseconds
· StopTime_ms: Stop time in milliseconds
· Input: Input during section sewing
· Output: Output during section sewing
· StopInputSignal: During stop, Input signal
· StopOutputSignal: During stop, Output signal
7. serivecalllog
Stores generated service call message data of each connected sewing machine. The service
information is computed by the com server application during following scenarios:
- Service call message is received by the com server
- When acknowledge message is received by the com server
- When mechanic login and logout of the particular sewing machine
Columns:
· MachineGUID (Primary-Key): Unique value created in the machine table, refer 'machine' table
in Machine Table
- Foreign key referenced from 'machinestatus' 'MachineGUID' column
· UpdateTime (Primary-Key): Date time of the sewing message received
· MessageBufferID (Primary-Key): Unique internal message ID value
77
90
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
· Source: Specifies the owner of the service call who can send the particular service call event
· OperatorName: User name while service call was received
· ServiceCallID: Each service call event is identified by this unique ID
- Service call ID is the service call number attached to a service call message
· Event: Each respective ID has a unique event, which specifies what each service call means
· AcknowledgeTime: Time when service call is acknowledged
· MechanicName: Name of the mechanic for servicing that particular machine
- If the field is empty then the mechanic has not logged-in to that particular machine for
servicing
· ServiceTime: Calculated based on the customer requirements [Seconds]
- Here service time is calculated as
- Service time = (MechanicLogoutTime - MechanicLoginTime)
· ServiceCallCategory: Specifies the priority level of each service call event
· MachineID: ID of the sewing machine
· Refer 'servicecallid' table in Other Table
8. lasterrorlog
Stores all the error messages received from the control box to com server application.
Columns:
· MachineGUID (Primary-Key): Unique value created in the machine table, refer 'machine' table
in Machine Table
- Foreign key referenced from 'machinestatus' 'MachineGUID' column
· UpdateTime (Primary-Key): Date time of the sewing message received
· MessageBufferID (Primary-Key): Unique internal message ID value
The combination of above three value will be unique value for each data entry in this table
· ErrorID: Unique error ID value
· Info: Error information sent from control box to com server application
79
77
91
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
9. parameter
Stores parameter and its values, which are configured in the com server application. It is an
individual table without any relation to other data table.
Columns:
· ParameterName (Primary-Key): Unique name of the specific parameter, which is a primary
key
· ParameterValue: Value of the particular parameter
6.2.4 Tables for pass-through command / responses to sewing machine control boxand vice versa
Tables for pass-through command / responses to sewing machine control
box and vice versa
The pass-though command/messages are implemented since version 1.6.0.2 of the communication
server.
These tables store the messages exchanged between the communication server application an
the sewing machine control boxes for the
messages EXCMD, EXRES and EXREQ.
These messages are not evaluated by the communication server application in any way.
· Messages received from a sewing machine control box are just in inserted into the table
receivedmessagefromcontrolbox.
It is in the responsibility of the end user to evaluate and delete the received messages from
the table.
· Messages to be send to a sewing machine control box are read from the table
sendmessagetocontrolbox.
A customer frontend application can insert commands and responses into this table. The
communication server will just send the messages stored in the table to the sewing machine
control box. The communication server only checks, if the message has a correct checksum. If
the checksum is wrong the message is just deleted from the table.
Messages are only send to a control box, if the control box is connected and powered on.
92
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
After sending a message the communication server deletes the message from the table.
The communication server checks every 100 milli seconds, if the are messages to be send.
An example of the processing of send/received messages is shown in the following figure.
93
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
1) receivedmessagefromcontrolbox - table format
CREATE TABLE `receivedmessagefromcontrolbox` (
`MessageGuid` varchar(255) NOT NULL
COMMENT 'Primary key for a received EXCMD,EXRES, EXREQ message from a sewing
machine control box.
The key is generated by the comm server application on the reception of a message.',
`MachineGUID` varchar(255) DEFAULT NULL
COMMENT 'unique id for a sewing machine control box',
`UpdateTime` datetime(6) DEFAULT NULL
COMMENT 'date and time of message insertion ',
`MessageBufferID` int(11) DEFAULT NULL
COMMENT 'related key for the message buffer entry',
`MachineID` int(11) DEFAULT NULL
COMMENT 'id of the machine',
`CircuitBoardNo` varchar(255) DEFAULT NULL
COMMENT 'CircuitBoardNo of the control box',
`SerialNo` varchar(255) DEFAULT NULL
COMMENT 'SerialNo of the control box',
`IPAddress` varchar(255) DEFAULT NULL
COMMENT 'IPAddress of the control box from which the message was received',
`MessageHex` varchar(4096) DEFAULT NULL
COMMENT 'MessageHex - the message in ASCII/Hexadecimal format',
`MessageBin` blob
COMMENT 'MessageBin - message in binary format',
PRIMARY KEY (`MessageGuid`)
) ENGINE=InnoDB DEFAULT CHARSET=utf8;
94
EFKA Industry 4.0 © 2019 BIASYS Systempartner GmbH
Database
2) sendmessagetocontrolbox - table format
CREATE TABLE `sendmessagetocontrolbox` (
`MessageGuid` varchar(255) NOT NULL
COMMENT 'primary key for message to be send to a control box.
The format shall be as for a ''Globally Unique Identifier'', but it can also be any
unique text value.',
`UpdateTime` datetime(6) DEFAULT NULL
COMMENT 'date / time value of message insertion.',
`IPAddress` varchar(255) DEFAULT NULL
COMMENT 'IP Address of the control box where the message shall be send to.',
`MessageHex` varchar(4096) DEFAULT NULL
COMMENT 'The message in ASCII/Hexadecimal format. The complete message from
<SOH> to >CRC>
Example: "01F1027B46324558434D443D312C302C313030302C03B9"
This field is only used, if the MessageBin field has a NULL value.',
`MessageBin` blob
COMMENT 'The message in binray format. The complete message from <SOH> to
>CRC>
If this field value is NULL the MessageHex field value is applied.',
PRIMARY KEY (`MessageGuid`)
) ENGINE=InnoDB DEFAULT CHARSET=utf8;