Overhead Insulation Piercing Connectors
TTD####XFBasic part number: con-nector with over-molded shear head and stainless
steel bolt, nut and washer.
TTD####XFTConnector with turbo
spacer
Sicame TTD Connector Features:
Installation : Simple, Fast and Reliable
• Determine direction for tap conductor to enter connector. Remove and discard the extra end cap.
• Insert tap conductor, • making sure con-
ductor is fully seated in end cap.
• Place connector on main conductor. Tighten screw(s) with a closed-end wrench or socket until the top shear-head breaks off.
TTD####XFB-TConnector with end cap position (splicing) and
turbo spacer.
1 2 3
Red ‘Turbo’ Spacer (FT)This feature allows the main wire to be in-serted and hand tightened, leaving the tap location completely open.
Splicing
Taps
Dead ends
Metering
FEATURES
• Easy installation – no cable
stripping
• Water tight connection
• Fully insulated, no exposed live
components
• UV stable
• Shear Bolt controls torque for
correct contact pressure
• Tinned copper teeth allow for
connections to either aluminum
or copper wire
TTD Series
APPLICATIONS
2
*Meets ANSI C119.4 and C119.5 Requirement 600 Volt Rated
*TTD5510XFBT
*TTD0510XF *TTD150XFT
TTD####XFB-T-UNIConnector with end cap
position (splicing), turbo spacer and blue insert
for use on bare wire.
*TTD2710XFBTUNI
TTD Series
Blue Rubber ‘UNI’ Insert (FBTUNI)This feature recreates insulation when used on bare wire. It is used to avoid any damage on neutral messenger. Remove this insert if the wire is insulated.
Overhead Insulation Piercing Connectors
TTD Series
4
Catalog Number
Conductor Size
14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750
TTD0510XFMainTap
TTD0810XFMainTap
TTD1010XFBTUNIMainTap
TTD1510XFTMainTap
TTD1810XFBTUNIMainTap
TTD2110XFBTUNIMainTap
TTD2610XFMainTap
TTD2710XFBTUNIMainTap
TTD4010XFBTMainTap
TTD4010XFTMainTap
TTD4310XFBTMainTap
TTD4510XFTMainTap
TTD5010XFBTMainTap
TTD5510XFBTMainTap
Part Number
Conductor RangeTorque in Inch lb.
Number of Bolts
Bolt Head Size in Inches
Qty. per Box
Current Rating Dimensions in Inches
Main AWG Tap AWGCU
AMPAL
AMPH W L
TTD0510XF 2/0 - 6 8 - 14 80 1 1/2 12 55 40 3.6 1.7 2.7
TTD0810XF 750 - 3/0 10 - 14 80 1 1/2 12 55 40 4.3 2.4 2.8
TTD1010XFBTUNI 1/0 - 8 2 - 10 80 1 1/2 12 190 150 3.7 2.0 3.0
TTD1510XFT 4/0 - 3 2 - 10 125 1 1/2 12 190 150 3.9 1.7 2.7
TTD1810XFBTUNI 1/0 - 8 1/0 - 8 125 1 1/2 12 190 150 3.7 2.0 3.0
TTD2110XFBTUNI 4/0 - 2 2/0 - 6 160 1 1/2 12 300 235 4.3 2.4 3.2
TTD2610XF 250 - 1 4/0 - 4 160 1 1/2 12 405 315 3.5 2.2 2.6
TTD2710XFBTUNI 4/0 - 2 4/0 - 4 160 1 1/2 12 405 315 4.4 2.4 3.2
TTD4010XFBT 350 - 1/0 350 - 1/0 330 2 5/8 4 570 445 5.4 3.1 5.0
TTD4010XFT 350 - 1/0 350 - 1/0 330 2 5/8 4 570 445 5.4 3.1 5.0
TTD4310XFBT* (500)350 - 2/0 4/0 - 4 330 2 5/8 4 405 315 5.4 3.1 5.0
TTD4510XFT 500 - 4/0 350 - 1/0 330 2 5/8 4 570 445 5.4 3.0 5.0
TTD5010XFBT 500 - 4/0 500 - 4/0 330 2 5/8 4 700 545 5.6 3.6 5.7
TTD5510XFBT* (750)500 - 250 500 - 250 330 2 5/8 4 700 545 5.6 3.6 5.7
MEDIUM VOLTAGE
TTDC454010FBA 4/0 - 1/0 4/0 - 1/0 220 2 5/8 3
TTDC455010FB 477 - 3/0 397 - 3/0 330 2 5/8 3
TTDC455310FA 477 - 3/0 3/0 - 2 330 2 5/8 3
*End cap on main side must be removed to reach maximum wire size shown in parenthesis
Note: Install with a 6 point socket
Note: Install with a 6 point socket
Ordering Information
Underground Insulation Piercing Connectors 6
Fully insulated, waterproof connector that
does not require stripping of the cable.
Piercing teeth allow for connections to either
aluminum or copper.
Ordering Information Piranha Series
Part Number Cable Range Number of Ports Qty. Per Box
PHM2-6-4/0
PHM2-14-1/0
PHS2-10-1/0
PHS-2-2-350
PHM3-12-1/0
PHM4-6-4/0T
PHM4-6-4/0B
PHMS4-6-4/0B
6 - 4/0
14 - 1/0
10 - 1/0
2 - 350
12 - 1/0
6 - 4/0
6 - 4/0
PHM5-250-350T
PHM5-250-350B
PHM5-6-4/0T
PHM5-6-4/0B
1/0 - 350
1/0 - 350
6 - 4/0
6 - 4/0
APPLICATIONS
FEATURES
PIRANHA Series
APPLICATIONS
• Connecting cables in pillar boxes
• Connections in underground pits
• Connections in streetlight columns
• Underground to overhead transi-
tions
• Buried service Connections
• Any ‘wet’ environment
• Waterproof
• Easy installation – no cable
stripping
• Fully insulated, no exposed live
components
• Shear Bolt controls torque for
correct contact pressure
• Flexible sealing cable ports that
are not affected by the angle of
cable entry
• Fitted with push-on protective
bolt caps
PHM5-4/0-500T
PHM6-6-350B
PHM6-6-500B*Also available in Transparent
4/0 - 500
2 @ 2 - 3504 @ 6 - 4/0
4/0 - 500
2@ 4/0 - 5004 @ 6 - 4/0
PHM5-4/0-500B
*Meets ANSI C119.1 and C119.4 Requirement 600 Volt Rated
6 - 4/0
2
2
2
2
3
4
4
4
5
5
5
5
5
5
6
6
12
12
10
4
6
9
9
12
6
6
9
9
6
6
6
5
4
Ordering Information
8
MTRS Series
Mechanical Tension Repair Splice
Repair splice for slack
and tensioned cables
FEATURES
• Large range taking ability
• Full tension mechanical connection
• Double shear head bolts
• Bolts never come in contact with
conductor
• Easy installation – use tools already
available on Line Trucks
• No cable brush required
• No dissimilar metals so no corro-
sion
• Cable is distended in a wave pattern
which greatly increases friction
• Rated for 10,000 lb
MTRS Series
APPLICATIONS
Ordering Information
Part #Conductor
Range
Conductor Area Range
(kcmils)
ConductorType
Nb of Bolts per slide
Bolt Head size (in)
Approx Torque to Shear theBolt (in-lbs)
First Second
Length (in)
10 3/8
13 1/2
15 7/8
17 3/4
*Meets ANSI C119.4 Requirement
Note: Install with a 3/4” impact socket
MTRS-04 and MTRS-02
480
520
780
780
620
700
1100
1100
3/4
3/4
3/4
3/4
4
5
5
5
aac/aaac/acSr/acar
aac/aaac/acSr/acar
aac/aaac/acSr/acar
aac/aaac/acSr/acar
41.7 - 106
106 - 212
168 - 370
330 - 570
#4 - 1/0
1/0 - 4/0
3/0 - 370 kcmil
330 - 570 kcmil
MTRS-01
MTRS-02
MTRS-03
MTRS-04
www.sicameusa.com
Sicame CorporationTelephone: (630) 238-6680
Fax: (630) 238-6682
Postal address:Sicame Corporation808 North Central Avenue - Unit FWood Dale, IL 60191
General Information:info@sicameusa.com
Sales & Customer Support:customerservice@sicameusa.com
Sending Purchase Orders:order@sicameusa.com
V1
top related