ericsson tower tube. top right corner for field-mark, customer or partner logotypes. see best...

Post on 14-Jan-2016

216 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Ericsson Tower Tube

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•2

The challenge

CREATE A NEW SITE THAT IS/HAS:

Easy to place and build1Easy to run and maintain2Cost effective in every aspect3Low environmental impact 4

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•3

The solution: THE ERICSSON TOWER TUBE

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•4

IT IS A REVOLUTIONARY SITE BUILDING CONCEPT

It’s a totally self contained site with room for all the equipment inside

It leaves a very small footprint

It’s architectural designed and has a character

What is it?

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•5

The design and construction

• All equipment inside

• Indoor climate

• Small footprintapprox. 5m diameter

FULLY ENCAPSULATED SITE

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•6

• Low feeder loss

• Positive impact on capacity, coverage and power consumption

• Prepared for site sharing

RBS IN THE TOP

The design and construction

Antenna Array

Radio base

stations

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•7

The design and construction

• No need for active cooling

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•8

The equipment is installed in the base of the tower…

… and is then lifted to the top with an elevator.

RBS IN THE TOP

The design and construction

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•9

THE RADOME PROTECTS THE ANTENNAS

• Protection from the weather, wind, dust and lightning

• 360° radio transparency

The design and construction

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•10

• Concrete with post-tentioned steel wires

• Thin walls, approx. 70mm

FLEXIBLE DESIGN

The design and construction

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•11

• Modular design

• Built-in lightning protection in the construction

MODULAR CONSTRUCTION

The design and construction

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•12

Superior design

Low deployment cost

Low cost to operate

Low environmental impact

Why the Ericsson Tower Tube?

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•13

Superior design

• Awarded with Wall Street’s ”Technology Innovation Award” and nominated with Design-S • Customized colors

• Accepted in the public environment • Easier to find site locations

• Creates a landmark and an opportunity for branding

Superior design

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•14

Low deployment cost

• Small footprint and attractive design makes it easy to find locations

• 60-75% less footprint needed, compared to traditional sites

Footprint of traditional site

Footprint of the Ericsson Tower Tube

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•15

Superior design

• Fences• Shelter• Grounding• Cooling• Feeders

…all included in theEricsson Tower Tube

Low deployment cost

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•16

Superior design

• Only indoor equipment is used• Less feeder loss, capacity/coverage increase for network planning• Macro flexibility

Low deployment cost

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•17

Low cost to operate

Consumes low amounts of energy

• No need for long feeders nor active cooling, reduces power consumption by approx. 40% compared to traditional sites

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•18

Superior design

Requires a minimum ofmaintenance

• No need for security

• No need for gardening

Low cost to operate

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•19

Low environmental impact

Saves energy

• Greatly reduced feeder loss and no need for active cooling

• A 40% CO2 emission reduction could be obtained

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•20

Superior design

Saves resources

• The construction material haslow environmental impact, uses 1/10th of steel compared to traditional sites

• CO2 emissions related to material – production and transport – are at least 30% lower

Low environmental impact

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•21

Welcome to experience for yourself!

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

•22109 - FGB 101 472 Uen Rev D •Commercial in confidence •2008-11-07•22

top related