EstimatingEstimatingEstimatingEstimatingEstimatingTTTTTemperemperemperemperemperaturaturaturaturature Risee Risee Risee Risee Riseofofofofof TTTTTrrrrransfansfansfansfansfororororormermermermermersssss
By calculating core losses and winding losses, transformer temperature
rise may be predicted. Through appropriate core material selection, corelosses may be minimized at the expected operating temperature.
BBBBBy Gy Gy Gy Gy Georeoreoreoreorge G.ge G.ge G.ge G.ge G.OrOrOrOrOrenchak,enchak,enchak,enchak,enchak, General Manager, TSCFerriteInternational, Wadsworth, Ill.
Transformers for power applicationsoften are limited in size by an accept-able temperature rise. An acceptabletemperature rise of a transformer isusually dependent on limitations of the
materials used in the transformer, safety agency regulationsor high-temperature reliability issues associated with othercomponent parts close to the transformer. The tempera-ture rise of a transformer is due to the power loss dissi-pated by the transformer in the form of heat. The powerloss of a transformer consists of core loss and of windingcoil losses, and can be predicted accurately.
Core LossesCore losses significantly contribute to the temperature
rise of a t ransformer. Hysteresis loss, eddy current loss andresidual loss all contribute to the total core loss. At highflux densities and relatively low frequencies, hysteresislosses are usually dominant.
Hysteresis loss is the amount the magnetization of the
ferrite material lags the magnetizing force because of molecular friction. The loss of energy caused by hysteresisloss is proportional to the area of the static or low-frequencyB-H loop. At high frequencies, eddy current losses usuallydominate. Eddy current losses result from a varying induc-tion that produces electromotive forces, which cause acurrent to circulate within a magnetic material.
These eddy currents result in energy loss. Understand-ing the behavior of the combined total core loss as func-tions of flux density and of frequency is most important.FigFigFigFigFig ..... 11111 shows the relationship of core loss versus frequencyfor power-grade ferrite materials. FigFigFigFigFig ..... 22222 shows the relation-ship of core loss versus flux density for power-gradeferrite materials. Manufacturers typically combine andexpand the information on FigFigFigFigFig s.s.s.s.s. 11111 and 22222 by publishing coreloss as a function of flux density at various frequencies andon logarithmic scales, as shown in FigFigFigFigFig ..... 3.3.3.3.3.
Notice both core loss versus frequency and core lossversus flux density relationships are exponential. Symmetri-cal sine wave, square wave and unidirectional square wave
voltage excitations all result inapproximately the same core loss,providing the frequency and totalflux density excursion remain thesame. Manufacturers t ypicallypublish core loss, as measured, us-ing symmetrical sinusoidal voltageexcitation.
For the excitation types men-tioned, core loss can be obtainedin a straightforward manner frommanufacturers’ published graphsor calculated from core loss for-
TSF-50ALL Flat Line
0
50
100
150
200
250
300
25 50 75 100 125 150 175 200 225 250 275Frequency (kHz)
C o r e l o s s ( m W / c c )
TSF-50ALL Flat Line
0100200300400500600700800900
1000
500 1000 1500 2000 2500 3000
Flux density (gauss)
C o r e l o s s ( m W / c c )
Fig. 1. Core loss versus frequency at 1000 gauss. Fig. 2. Core loss versus flux density at 100 kHz.
8/6/2019 Estimating Temperature Rise of Transformers Orenchak G. 2004)
http://slidepdf.com/reader/full/estimating-temperature-rise-of-transformers-orenchak-g-2004 2/5
8/6/2019 Estimating Temperature Rise of Transformers Orenchak G. 2004)
http://slidepdf.com/reader/full/estimating-temperature-rise-of-transformers-orenchak-g-2004 3/5
Power Electronics Technology July 2004 www.powerelectron18
make materials that have minimumcore loss near the expected workingtemperature.
Numerous material grades opti-
mized for a specific ideal operatingtemperature now exist. The presentbrings additional discoveries that en-able ferrite manufacturers to developnew material grades that exhibit thesame low core loss over a wider oper-ating temperature range (50 mW/cm 3
at 100 kHz, 1000 gauss from roomtemperature to more than 100°C).
This new material grade will contr ib-ute to more energy-efficient productsbecause the core loss will be opt imizedover the entire operating tempera-
ture range. Products made fromthese materials will be safer becausethe chance of thermal runaway willbe less. These new material gradesalso will minimize required core in-ventories because one grade of mate-rial will be optimal for all power ap-plications, regardless of operatingtemperature.
Ferrite Material PropertiesAlthough material properties other
than core loss are unimportant in de-termining temperature rise or coresize of a transformer, other proper-ties are of interest if integrated mag-
netics (transformers and inductorswound on a common magnetic core)are being considered.
The magnitude and stability of TSF-50ALL Flat Line’s initial perme-ability over a wide operating tempera-ture may be advantageous for somelow flux-density signal applications.
Transformer applications requireenough permeability to providea good flux path so flux stays in theintended path and doesn’t stray out
of the core. Output power inductorapplications predominantly requirea gapped core. The gap depth sizebecomes a dominant factor while de-termining the component inductanceand the material permeability is rela-tively unimportant.
Transformer core size is often con-strained by the core loss of the core
TEMPERATURE RISE
020406080
100120140160180200
-20 0 20 40 60 80 100 120 140 160Temperature (°C)
C o r e l o s s
( m W / c c )
TSF-50ALL Flat LineTSF-5099TSF-7099 & TSF-boostTSF-7070TSF-8040TSF-5000
Fig. 5. Core loss versus temperature.
CIRCLE217 on Reader Service Card or freeproductinfo.net/pet
8/6/2019 Estimating Temperature Rise of Transformers Orenchak G. 2004)
http://slidepdf.com/reader/full/estimating-temperature-rise-of-transformers-orenchak-g-2004 4/5
Power Electronics Technology July 2004 www.powerelectron20
material. However, power inductorcore size is often constrained by thecore material’s saturation propertiesat operating temperatures.
Winding Coil Losses
Winding coil losses contribute toa transformer’s total loss. Copperlosses (I 2R losses) are easy to under-stand. Winding coil losses due to skineffect, proximity effect, effect of eddy
currents in the windings, effects fromfringing flux intersecting windingsnear the core gap, edge effects and ex-traneous conductor effects may be sig-nificant and should be considered. Forsimplicity, we’ll ignore these addi-
tional winding losses and consideronly I 2R copper losses.The resistance of each winding can
be calculated by mult iplying the meanlength turn of the winding by the cop-
per resistance for the appropriate wiresize and by the total turn count .RP or R S= MLT * R CU * NWhere:RP = primary coil resistance inRS = secondary coil resistance in
MLT = mean length turn in cmRCU = copper resistance in µ /cmN = turn count
The copper losses for each wind-ing are calculated with the followingformulaPCU = I 2 RWhere:PCU = copper loss in wattsI = current in ampsR = resistance in
Sum the primary and all the sec-
ondary winding losses to obtain thetotal winding losses, and then sum thetotal winding losses with the corelosses to obtain the total transformerlosses (P ).
Temperature RiseA transformer’s output power is
less than its input power. The differ-ence is the amount of power convertedinto heat by core loss and windinglosses. A combination of radiationand convection dissipate this heatfrom the exposed surfaces of the trans-former. Thus, the heat dissipation isdependent upon the total exposedsurface area of the core and the totalexposed surface area of the windings.
Temperature rise of a transformeris hard to predict with precision. Oneapproach is to lump the winding lossestogether with the core losses and as-sume that the thermal energy is dissi-pated uniformly throughout the sur-face area of the core and winding as-sembly at all ambient temperatures.This isn’t a bad assumption, becausethe majorit y of the trans-former’s sur-face area is ferrite core area rather thanwinding area, and the thermal conduc-tivity of ferrite (~40 mW/cm/ °C) ispoor at any temperature. With theseassumptions, the temperature rise of a transformer can be estimated by thefollowing formula:
T = (P /AT)0.833
Where:T = temperature rise in °C
TEMPERATURE RISE
CIRCLE222 on Reader Service Card or freeproductinfo.net/pet
Power =
6 Million Parts
www.elnamagnetics.comTOLL FREE: 800-553-2870
FAX: 845-679-7010E-MAILinfo@elnamagnetics.com
ELNAhas been distributing
and machining ferrite since1963. We offer competitivepricing, a knowledgeable andfriendly sales staff and thecores and accessories youneed, when you need them.If you require design assistance,contact our experienced staffof application engineers.
ELNA stocks the power cores you need.Whatever your ferrite requirements – you can depend on ELNA.
Our more than six million parts in inventory take thelead-times out of deliveries.
Authorized Distributor for:
8/6/2019 Estimating Temperature Rise of Transformers Orenchak G. 2004)
http://slidepdf.com/reader/full/estimating-temperature-rise-of-transformers-orenchak-g-2004 5/5
Power Electronics Technology July 2004 www.powerelectron22
TEMPERATURE RISE
P = total transformer losses (power lost and dissipated asheat) in mW; A T = surface area of transformer in cm 2.
The exponent (0.833) used in the above formula to es-timate temperature rise has been derived from empiricaldata with the use of the following formula:x=ln(P @1st T/P @2nd T)/ln(1st T/2nd T)
FigFigFigFigFig ..... 66666 shows temperature rise versus power loss for sev-eral different size E core transformers.
The temperature rise of a transformer results in partfrom core loss and in part from winding coil losses. The
0
10
20
30
4050
60
70
80
90
100
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
Transformer power loss (mW)
T e m p e r a t u r e r i s e
( ° C )
19-08-05
25-10-06
32-16-09
41-16-1242-21-15
55-28-21
70-54-3280-38-20
Fig. 6. Temperature rise versus transformer power loss.
core losses and winding losses and temperature rise can beestimated with calculations by making a few assumptions.Because of the assumptions made, it may be necessary toprove the temperature rise empirically by measuring thetransformer using thermal couples. New ferrite materialsthat exhibit consistent core loss over a wide range of oper-
ating temperatures will simplify ferrite material selectionand prove valuable to the transformer industry. PETPETPETPETPETec hec hec hec hec h
References1. Snelling, E.C. “Soft Ferrites Proper ties and Applications,Second Edit ion,” Butterworth, 1988.2. McLyman, C. Wm. T. “Magnetic Core Selection for Trans- formers and Inductors,” Marcel Dekker Inc., 1982.3. McLyman, C. Wm. T. “Transformer and Inductor Design Handbook,” Marcel Dekker Inc., 1978.4. Jamerson, Clifford. “Targeting Switcher Magnetics Core Loss Calculat ions,” Power Electronics Technology, February
2002, Vol. 28, No. 2.5. Carsten, Bruce. “High Frequency Conductor Losses in Switchmode Magnetics,” PCIM, November 1986.6. “Soft Ferrites: A User’s Guide,” Magnetic Materials Producers Association, MMPA SFG-98, 1998.
For more information on this article,CIRCLE330 on Reader Service Card