fi ff450 downloads brochure
Post on 07-Nov-2015
16 Views
Preview:
DESCRIPTION
TRANSCRIPT
-
FF450plus Fundus Camera with VISUPACA powerful diagnostic duo
-
The optical zoom allows for incredible details at 20 and 30 as well as a complete overview at 50
2
FF450plus fundus camera with VISUPACA superb system for diagnostic precision
The FF450plus fundus camera combined with the VISUPAC imaging system stands for diagnostic precision. Whether for glaucoma, AMD or diabetic retinopathy examinations, it delivers images of excellent quality and diagnostic detail for various imaging modes. Together, FF450plus and VISUPAC provide a consistent high level of measurement precision and reliable operation.
Create exceptional panoramic images at the push
of a button
Convenience you can feel
VISUPAC features an extensive image processing, editing and measurement
suite. Disease documentation can be enriched with markings and annotations
for future reference or for image overlay to visualize disease progression. A
unique AutoMap function lets you create magni cent wide-angle panoramic
images at the push of a button.
Quality you can see
The renowned optical quality of the FF450plus and integration with
VISUPACs digital imaging capabilities makes the difference. The result is
images of exquisite detail a must for today's demanding ophthalmic
professionals be it for disease documentation, presentations, or for use in
clinical trials. Its optical zoom features three magni cation levels (20, 30
and 50) for optimal diagnostic insight. In addition, the highly exible tilt
and swivel mechanism allows imaging from virtually any angle.
-
3The standard con guration of the FF450plus is equipped for color imaging, uorescein angiography and lter-based red-free, red and blue imaging
Measurements you can trust
The exclusive ZEISS telecentric optics of the FF450plus provide constant
magni cation, independent of focusing and position, resulting in virtually no
distortion. Together with VISUPACs uniquely harmonized sensors, this enables
you to accurately and repeatedly measure and analyze disease progression.
Image management so you can manage disease
Integrated data management functions enable fast, easy and secure
documentation and storage of examination results for a comprehensive
review and disease management. The built-in search function lets you easily
query your patient and image database over numerous parameters for
convenient data access.
Technology you can build on
Ophthalmic solutions from ZEISS are built for reliability and solid return on
investment as is the FF450plus fundus camera with VISUPAC. As a scalable
system with a modular design, it can be upgraded at any time to suit future
needs for example, adding indocyanine-green angiography or fundus auto
uorescence to expand your retinal diagnostic procedures.
The exclusive ZEISS telecentric optics provide
repeatable and precise measurements of retinal
physiology
VISUPAC's comprehensive patient management
system allows you to query patient data over
multiple parameters
-
Carl Zeiss Meditec AGGoeschwitzer Strasse 515207745 JenaGermanywww.meditec.zeiss.com/visupacwww.meditec.zeiss.com/contacts
Your local contact:
ArgentinaCarl Zeiss Argentina S.A.Calle Nahuel Huapi 4015 / 25C1430 BCO Buenos AiresArgentinaPhone: +54 11 45 45 66 61bruzzi@zeiss.com.ar
AustraliaCarl Zeiss Pty LtdTenancy Office 4, Level 140-52 Talavera RoadNorth Ryde NSW 2113AustraliaPhone: +61 2 9020 1333med@zeiss.com
AustriaCarl Zeiss GmbHLaxenburger Str. 21100 ViennaAustriaPhone: +43 1 79 51 80austria@zeiss.org
BelgiumCarl Zeiss NV-SAIkaroslaan 491930 ZaventemBelgiumPhone: +32 2 719 39 11info@zeiss.be
BrazilCarl Zeiss do Brasil Ltda.Av. Naoes Unidas, 21711CEP04795-100 So PauloBrazilPhone: +55 11 5693 5521medbrasil@zeiss.org
CanadaCarl Zeiss Canada Ltd.45 Valleybrook DriveToronto, ON M3B 2S6CanadaPhone: +1 800 387 8037micro@zeiss.com
ChinaCarl Zeiss Shanghai Co. Ltd.1/f., Ke Yuan Building11 Ri Yin Nan RoadWaigaoqiao Free Trade Zone2005 Yang Gao Bei RoadShanghai 200131ChinaPhone: +86 21 5048 17 17sro@zeiss.com.cn
Czech RepublicCarl Zeiss spol. s.r.o.Radlick 14/3201150 00 Prague 5Czech RepublicPhone: +420 233 101 221zeiss@zeiss.cz
FranceCarl Zeiss Meditec France SAS60, route de Sartrouville78230 Le PecqFrancePhone: +33 1 34 80 21 00med@zeiss.fr
GermanyCarl Zeiss Meditec VG mbHCarl-Zeiss-Strasse 2273447 OberkochenGermanyPhone: +49 7364 20 6000vertrieb@meditec.zeiss.comSurgical Ophthalmology:Phone: +49 800 470 50 30iol.order@meditec.zeiss.com
Hong KongCarl Zeiss Far East Co. Ltd.Units 11-12. 25/FTower 2, Ever Gain PlazaNo. 88 Container Port RoadKwai ChungHong KongPhone: +852 2332 0402czfe@zeiss.com.hk
IndiaCarl Zeiss India Pvt. Ltd.22. Kensington RoadUlsoorBangalore 560 008IndiaPhone: +91 80 2557 88 88info@zeiss.co.in
ItalyCarl Zeiss S.p.A.Viale delle Industrie 2020020 Arese (Milan)ItalyPhone: +39 02 93773 1infomed@zeiss.it
JapanCarl Zeiss Meditec Japan Co. Ltd.Shinjuku KuTokyo 160-000322 Honchio-ChoJapanOphthalmic instruments:Phone: +81 3 33 55 0331medsales@zeiss.co.jpSurgical instruments:Phone: +81 3 33 55 0341cmskoho@zeiss.co.jp
MalaysiaCarl Zeiss Sdn Bhd.Lot2, Jalan 243/51 A46100 Petaling JayaSelangor Darul EhsanMalaysiaPhone: +60 3 7877 50 58malaysia@zeiss.com.sg
MexicoCarl Zeiss de Mxico S.A. de C.V.Avenida Miguel Angel de Quevedo 49604010 Mexico CityMexicoPhone: +52 55 59 99 0200cz-mexico@zeiss.org
NetherlandsCarl Zeiss B.V.Trapezium 300Postbus 3103364 DL SliedrechtNetherlandsPhone: +31 184 43 34 00info@zeiss.nl
New ZealandCarl Zeiss NZ Ltd15B Paramount DriveP.O. Box 121 - 1001Henderson, Auckland 0650New ZealandPhone: +64 9 838 5626med@zeiss.com
PolandCarl Zeiss sp. Z o.o.ul. Lopuszanska 3202-220 WarsawPolandPhone: +48 22 858 2343medycyna@zeiss.pl
SingaporeCarl Zeiss Ptd. Ltd.50 Kaki Bukit PlaceSingapore 415926SingaporePhone: +65 6741 9600info@zeiss.com.sg
South AfricaCarl Zeiss (Pty.) Ltd.363 Oak AvenueFerndaleRandburg 2194South AfricaPhone: +27 11 886 9510info@zeiss.co.za
South KoreaCarl Zeiss Co. Ltd.Seoul 121-828Mapo-gu141-1, Sangsu-dong2F, BR Elitel Bldg.South KoreaPhone: +82 2 3140 2600korea@zeiss.co.kr
SpainCarl Zeiss Meditec Iberia S.A.Ronda de Poniente, 15Tres Cantos28760 MadridSpainPhone: +34 91 203 37 00info@zeiss.es
SwedenCarl Zeiss ABTegeluddsvaegen 7610254 StockholmSwedenPhone: +46 84 59 25 00info@zeiss.se
SwitzerlandCarl Zeiss AGFeldbachstrasse 818714 FeldbachSwitzerlandPhone: +41 55 254 7534med@zeiss.ch
ThailandCarl Zeiss ThailandFloor 8, Thosapol Land Building 2230 Ratchadapisek RoadHuaykwang, Bangkok 10310ThailandPhone: +66 2 2 74 06 43thailand@zeiss.com.sg
United KingdomCarl Zeiss Ltd.15-20 Woodfield RoadWelwyn Garden CityHertfordshire, AL7 1JQUnited KingdomPhone: +44 1707 871200info@zeiss.co.uk
United States of AmericaCarl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAPhone: +1 925 557 4100info@meditec.zeiss.com
SAP
0000
00-1
970-
082
CAM
.405
5 Pr
inte
d in
Ger
man
y CZ
-X/2
011
The
cont
ents
of t
he b
roch
ure
may
diff
er fr
om th
e cu
rrent
sta
tus
of a
ppro
val o
f the
pro
duct
in y
our c
ount
ry. P
leas
e co
ntac
t our
regi
onal
repr
esen
tativ
e fo
r mor
e in
form
atio
n. S
ubje
ct to
ch
ange
in d
esig
n an
d sc
ope
of d
eliv
ery
and
as a
resu
lt of
ong
oing
tech
nica
l dev
elop
men
t. VI
SUPA
C is
eith
er tr
adem
ark
or re
gist
ered
trad
emar
k of
Car
l Zei
ss M
edite
c AG
in G
erm
any
and/
or
othe
r cou
ntrie
s. P
rinte
d on
ele
men
tal c
hlor
ine-
free
blea
ched
pap
er.
2
011
by C
arl Z
eiss
Med
itec
AG. A
ll co
pyrig
hts
rese
rved
.
VISUPAC, FF450plus
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.16667 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile (None) /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice
top related