field drainage field drainage pumping systemspumping systems … · field drainage field drainage...
Post on 26-Jul-2018
230 Views
Preview:
TRANSCRIPT
FIELD DRAINAGE FIELD DRAINAGE
PUMPING SYSTEMSPUMPING SYSTEMS
Agriculture Lift Station Pumps
Corrosion Resistant Stainless Steel Construction
High Volume: 75 to 1,400 GPM
Low Head: 2' to 25' of Total Dynamic Head
Single or Three Phase Power Flexibility
1 to 15 Horsepower
200, 230, 460 or 575 Volts
Fixed or Variable Speed
Vertical or Horizontal Style
Axial-Flow Lift for Low Vibration,
Low Pressure Operation
Economical and Efficient
Powered by Reliable Franklin Motors
Water Lubricated Motor - Environmentally Safe
(No lubrication needed)
No Unsightly Mechanical Parts Above Ground
Low Maintenance Requirements
Strainer Screens Available
VARIABLE-FLOW PUMPING APPLICATIONS
VFD
Level Transducer
Achieve Higher Flow Rates with Less Horsepower
Allows Small Capacity Wet Wells to be Used with Large Capacity Pumps
Less Water Storage Capacity Required
Lower Minimum Pumping Depths
Match the Pump Speed and Discharge Flow Rate to the Ever-Changing Drainage Flow Rate
Provides Additional Safety Features over Conventional Systems:
Quicker Overload Protection No-Flow Shutdown
Reduces or Eliminates Short Cycling Less Motor Heat
Low Inrush Power on Start-up
Faster Water Table Drain-Down Times
Three Phase Pumps Can Tolerate More Frequent Starts Per Hour than
Single Phase Pumps
Single and Three Phase Input Power Options
Effective with Multi-Pump Applications
Simple Field Adjustable Parameters for Start, Stop and Full Speed Ratio
Dynamic Braking to Prevent Back Spinning
No Floats: Uses Non-Mechanical Level Transducer
5HP Carry Pump
Flow Sensor
VFD Winter Cover
CARRY VFD PUMPS PERFORMANCE CURVESCARRY VFD PUMPS PERFORMANCE CURVESCARRY VFD PUMPS PERFORMANCE CURVES
DRAIN
COEFFICIENT
INCH/24 HRS 40 80 120 160 200 240 280 320
1/8 INCH 95 GPM 190 GPM 285 GPM 380 GPM 475 GPM 570 GPM 665 GPM 760 GPM
1/4 INCH 190 GPM 375 GPM 570 GPM 750 GPM 950 GPM 1140 GPM 1330 GPM 1520 GPM
3/8 INCH 280 GPM 560 GPM 840 GPM 1120 GPM 1400 GPM 1680 GPM 1960 GPM 2240 GPM
1/2 INCH 375 GPM 750 GPM 1125 GPM 1500 GPM 1875 GPM 2250 GPM 2625 GPM 3000 GPM
3/4 INCH 560 GPM 1120 GPM 1680 GPM 2240 GPM 2800 GPM 3360 GPM 3920 GPM 4480 GPM
LIFT STATION STORAGE CAPACITY: This is the amount of water between the PUMP Off and PUMP ON locations in the wet well.
IF USING A FIXED SPEED PUMP: The storage capacity should be 1 to 2 times the flow rate of the pump.
IF USING A VARIABLE SPEED PUMP: The storage capacity should be 25-50% of the maximum flow rate of the pump.
TOTAL DYNAMIC HEAD: This is the pressure the pump will experience during pumping. It is the vertical rise in feet of the pumping
system plus the friction loss in the piping.
ACRES IN WATERSHED AREA
Carry Manufacturing, Inc.
1360 Prospect Avenue, Caro, MI 48723-9288
Phone: 800-49-CARRY or 989-672-2779
Fax: 888-502-8289 or 989-672-2770
Email: carrymfg@aol.com
www.carrymfg.com
PUMP ACCESSORIES
VFD
Flow Sensor
Transducer
PVC
Strainer
Screens
CARRY VFD PUMPS PERFORMANCE CURVESCARRY VFD PUMPS PERFORMANCE CURVESCARRY VFD PUMPS PERFORMANCE CURVES
VFD Winter
High Volume/Low Head Stainless Steel Pumps
Economical and Efficient Solution to
Your Pumping Needs
Constant Speed Pumps
Single and Three Phase Power Options
Flow Rates up to 1400 GPM
4” or 6” Discharge Size
Dual Float Level Control for Pumping
Differentials up to 3.5’
Duplex/Triplex Options
DFD Floats
Single Phase Control Panel
Three Phase Control Panel
FIXED SPEED PUMPING APPLICATIONS
1-1/2HP Carry Pump
top related