fill SQUARE D

www.SquareD.comFor the most up-to-date information

Thermal-magnetic Molded Case Circuit Breakers100, 250 Ampere FrameClass 525, 650, 734, 820

F-frame—100 A, Thermal-magnetic (600 Vac)

ContinuousCurrentRating@40°C

AC MagneticTrip Settings

Hold Trip

Standard Interrupting

CatalogNumber Price

High Interrupting

CatalogNumber Price

Current Limiting

CatalogNumber Price

TerminalWire

Range

1-pole, 277 Vac, 125 Vdc

FIL36100

-, ,.„,,

152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FHL16015FHL16020FHL16025FHL16030FHL16035FHL16040FHL16045FHL16050FHL16060FHL16070FHL16080FHL16090FHL16100

$301.301.301.301.

301.301.301.301.301.339.339.339.339.

AL50FA#14-#4AWGCuor

*12-#4AWGAI

AL100FA#14-#1/OAWGCuor

#12-#1/OAWGAI

2-pole. 600 Vac, 250 Vdc152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL26015FAL26020FAL26025FAL26030FAL26035FAL26040FAL26045FAL26050FAL26060FAL26070FAL26080FAL26090FAL26100

S469.469.469.469.

469.469.469.469.469.593.593.593.593.

FHL26015FHL26020FHL26025FHL26030FHL26035FHL26040FHL26045FHL26050FHL26060FHL26070FHL26080FHL26090FHL26100

$775.775.775.775.

775.775.775.775.775.902.902.902.902.

FIL26020FIL26025FIL26030FIL26035FIL26040FIL26045FIL26050FIL26060FIL26070FIL26080FIL26090FIL26100

$1755.1755.1755.1755.1755.1755.1755.1755.1755.1755.1755.1755.

AL50FA#14-44 AWGCu or

#12-#4 AWG Al

AL100FA#14-#1/OAWGCuor

#12-#1/OAWGAI

3-pole,600Vac,250VdcGJL 3-pole

circuit breaker152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL36015FAL36020FAL36025FAL36030FAL36035FAL36040FAL36045FAL36050FAL36060FAL36070FAL36080FAL36090FAL36100

$604.604.604.604.

604.604.604.604.604.743.743.743.743.

FHL36015FHL36020FHL36025FHL36030FHL36035FHL36040FHL36045FHL36050FHL36060FHL36070FHL36080FHL36090FHL36100

$ 905.905.905.905.

905.905.905.905.905.

1027.1027.1027.1027.

FIL36020FIL36025FIL36030FIL36035FIL36040FIL36045FIL36050FIL36060FIL36070FIL36080FIL36090FIL36100

$2197.2197.2197.2197.2197.2197.2197.2197.2197.2197.2197.2197.

AL50FA#14-#4 AWG Cu or

#12-#4AWGAI

AL100FA#14-#1/0 AWG Cu or

#12-#1/OAWGAI

POWERPACT8 G-frame—100 A, Thermal-magnetic (600Y/347 Vac)

Continuous CurrentRating ® 40° C

AC Magnetic Trip SettingsHold | Trip

J InterruptingCatalog Number ] Price

Terminal WireRange

3-pole,Vac,Vdc

QBL2 and 3-pole

70-250 Amperes

152030405060708090

100

600600600600800800800800800800

1200120012001200140014001400140014001400

GJL36015GJL36020GJL36030GJL36040GJL36050GJL36060GJL36070GJL36080GJL36090GJL36100

$1327.1327.1327.1327.1327.1327.1632.1632.1632.1632.

#14-#1/OAWGCu#8-#1/OAWGAI

POWERPACT Q-frame*—250 A, Thermal-magnetic (240 Vac)

ContinuousCurrentRating®40°C

AC MagneticTrip Settings

Hold Trip

B Interrupting

CatalogNumber Price*

D Interrupting

CatalogNumber Price*

G Interrupting

CatalogNumber Price*

J Interrupting

CatalogNumber Price*

2-pole,240Vac

Interrupting Ratings (kA)

240V

480V

600V

240V

480V

600V

FAL

25

18

14

GJL

100

65

18«

FHL

25 (1P:35-100 A), 65 (2, 3P)

25 (2, 3P)

18(2, 3P)

QB

10

QD

25

OG

65

FIL

200

200

100

QJ

100* 3-pole, 240 Vac

» GJL is rated 18 kA at 600Y/347 Vac.* 3-pole QJ circuit breakers are rated at 208Y/120 Vac only.

Accessories pages 6-36-6-38Optional Lugs pages 6-43, 6-44Dimensions pages 6-49, 6-50Enclosures pages 6-51-6-54

© 2003 Schneider ElectricAll Rights Reserved9/8/03

708090

100110

125150175200225250

10001000100012001200

12001200120012001200

1200

18001800180024002400240024002400240024002400

QBL22070QBL22080QBL22090QBL22100QBL22110QBL22125QBL22150QBL22175QBL22200QBL22225QBL22250"

$316.316.316.316.316.

316.316.316.316.316.

462.

QDL22070QDL22080QDL22090QDL22100QDL22110QDL22125QDL22150QDL22175QDL22200QDL22225QDL22250"

$ 762.762.762.762.762.

762.762.762.762.762.

1029.

QGL22070QGL22080QGL22090QGL22100QGL22110QGL22125QGL22150QGL22175QGL22200QGL22225QGL22250"

$1014.1014.1014.1014.1014.1014.1014.1014.1014.1014.1313.

QJL22070QJL22080QJL22090QJL22100QJL22110QJL22125QJL22150QJL22175QJL22200QJL22225QJL22250"

$1260.1260.1260.1260.1260.1260.1260.1260.1260.1260.1565.

708090

100110

125150175200225250

10001000100012001200

12001200120012001200

1200

18001800180024002400240024002400240024002400

QBL32070QBL32080QBL32090QBL32100QBL32110QBL32125QBL32150QBL32175QBL32200QBL32225QBL32250"

832.832.832.832.832.

832.832.832.832.832.

1208.

QDL32070QDL32080QDL32090QDL32100QDL32110QDL32125QDL32150QDL32175QDL32200QDL32225QDL32250"

1189.1169.1189.1189.1189.1189.1189.1189.1189.1189.1628.

QGL32070QGL32080QGL32090QGL32100QGL32110QGL32125QGL32150QGL32175QGL32200QGL32225QGL32250"

1628.1628.1628.1628.1628.1628.1628.1628.1628.1628.2100.

QJL32070QJL32080QJL32090QJL32100QJL32110QJL32125QJL32150QJL32175QJL32200QJL32225QJL32250"

1864.1864.1864.1864.1864.1864.1864.1864.1864.1864.2310.

. Replacement lugs are not available for POWERPACT Q-frame circuit breakers. Lugs for the POWERPACT Q-frame circuit breakersaccept (1) #14 AWG-300 kcmil.

' 250 A lugs are suitable for copper conductors only.

*DE2A DE2 DiscountSchedule 6-21

jljl SQUARE ID

www.SquareD.comFor the most up-to-date information

Selection InformationClass 500, 600, 800

150 A Frame 250 A Frame 250 A Frame 250 A Frame

Circuit Breaker Type CJ CG CJ QB QD QG QJ KA KH KC

Number of Poles 3,4 3.4 3,4 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3

Current Range 175-250 70-250A 70-250A 70-250A 70-250A 70-250 70-250 110-250 110-250

Interrupting Ratings

UL/CSA/NOMRating(kA RMS)(50/60 Hz AC)

DC Ratings

240 Vac

480Y/277 Vac

480 Vac

600Y/347Vac

600 Vac

250 VdC

500 VdC •

IEC 41 5/240 Vac (Icu/lcs) T

IEC 50/60 Hz

100

65

65

25

70

65

35

35

18

36

100

65

65

25

70

10

10/5

25

10/5

65

10/5

100

10/5

42

25

25

22

22

10

10/2.5

65

35

35

25

25

50

20

10/2.5

100

65

65

65/65

200

200

200

100

100

130/65

For additional IEC ratings, see Supplemental Digest.

Special Ratings

Fed. Specs W-C-375B/GEN

HACR (2, 3-pole) / / /

Connections/Terminations

Unit Mount

I-LINE®

Rear Connection

Drawout

Optional Lugs

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

^

/

/

/

/

/

/

/

/

/

/

Accessories and Modifications

Shunt Trip

Undervoltage Trip

Auxiliary Switches

Alarm Switch

Motor Operator

Handle Operators

Mechanical Interlocks (3-pole)

Handle Padlock Attachment

Cylinder Lock (3-pole)

Optional GF Protection

/

/

/

/

/

/

/

/

/

^/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/A

/A

/A

/A

/

/

/

/A

/*

/A

/A

/A

/A

/

/

/

/A

/*

/A

/A

/A

/A

/

/

/

/*

/A

/A

/A

/A

/

/

/*

Trip System Type

Thermal-magnetic

Instantaneous-trip {3-pole)

Molded Case Switch (Automatic)

Electronic

/

/

/

/

/

/

/

/

/

/

/

/ / / /

/

/

/

/

/ /

Enclosures (Pages 6-51-6-54)

General Purpose (NEMA 1)

Raintight (NEMA 3R)

Dustight(NEMA12)

Watertight (NEMA 4. 4X. 5)

Explosion Proof (NEMA 7. 9)

Dimensions(3P Unit Mount)

Height IN (mm)

Width IN (mm)

Depth IN (mm)

Pages (Unit Mount)/(l-LINE)

7.44(189)

4.13(105)

3.38 (86)

D

7.44(189)

4.13(105)

3.38(86

D

/

/

/

/

/

/

/

/

6.47(164)

4.5(114)

3.93 (100)

Page 6-21/8-26

/

/

/

/

J

/

/

/

/

/

/

/

/

/

/

/

8(203)

4.5(114)

4.75(121)

Page 6-22/8-27

Note: AH circuit breakers on this chart;A Factory-installed option only• Ungrounded UPS systems only.

See Supplemental Digest.

© 2003 Schneider ElectricAll Rights Reserved9/8/03

ire UL Listed and CSA Certified unless otherwise noted.• Requires breaker with WB suffix .* Requires factory-installed "G" Shunt trip and 3-pole module.T Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see Supplemental Digest.A I-LINE Q-frame circuit breakers are available 70-225 A only. 250 A Q-frame unit-mount circuit breakers are limited to copper conductors only.D See Supplemental Digest.

6-5

Thermal-magnetic Molded Case Circuit Breakers100 Ampere FrameClass 650

[Ij| SQUARE O

www.SquareD.comFor the most up-to-date information

Thermal-magnetic molded case circuit breakers shown onpages 6-20-6-24 are permanent trip UL Listed, CSA

Certified, IEC rated, and also meet the requirements ofFederal Specification W-C-375B/GEN as indicated on

pages 6-4-6-7. For I-LINE® molded case circuit breakers,

see listings on pages 8-25-8-28.

F-frame—100 A, Thermal-magnetic (240 Vac)

ContinuousCurrent Rating

@40°C

AC MagneticTrip Settings

Hold | Trip

Standard Interrupting

Catalog Number Price

TerminalWire

Range

1-pole, 120 Vac152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL12015FAL12020FAL12025FAL12030FAL12035FAL12040FAL12045FAL12050FAL12060FAL12070FAL12080FAL12090FAL12100

S132.132.132.132.

132.132.132.132.132.174.174.174.174.

AL50FA#14-04 AWGCu or

«12-#4AWG Al

AL100FA#14-#1/OAWGCu

or#12-#1/OAWGA!

2-pole, 240 Vac

FAL1-pole

15-100 Amperes

152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL22015FAL22020FAL22025FAL22030FAL22035FAL22040FAL22045FAL22050FAL22060FAL22070FAL22080FAL22090FAL22100

S222.222.222.222.

222.222.222.222.222.362.362.362.362.

AL50FA#14-#4 AWGCuor

#12-*4AWGAI

AL100FA#14-#1/OAWGCu

or#12-#1/OAWG Al

3-pole,240Vac

FAL/FHL2-pole

15-100 Amperes

152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL32015FAL32020FAL32025FAL32030FAL32035FAL32040FAL32045FAL32050FAL32060FAL32070FAL32080FAL32090FAL32100

$330.330.330.330.

330.330.330.330.330.469.469.469.469.

AL50FA#14-#4 AWGCuor

*12-*4AWG Al

AL100FAM4-#1/OAWGCu

or#12-»1/OAWGAI

F-frame—100 A, Thermal-magnetic (480 Vac)

ContinuousCurrentRating

@40°C

AC MagneticTrip Settings

Hold Trip

StandardInterrupting

CatalogNumber Price

Extra HighInterrupting

CatalogNumber Price

Terminal WireRange

FA Lugs FC Lugs

1-pole, 277 Vac, 125 Vdc

FAL/FHL/FCL3-pole

15-100 Amperes

152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL14015FAL14020FAL14025FAL14030FAL14035FAL14040FAL 14045FAL14050FAL14060FAL14070FAL14080FAL14090FAL14100

$167.167.167.167.

167.167.167.167.167.208.208.208.208.

AL50FA#14-#4 AWGCuor

#12-*4AWGAI

AL100FA#14-» 1/0 AWGCuor

#12-»1/OAWG Al

2-pole,480Vac,250Vdc«

Interrupting Ratings (kA)

240V

480V

600V

FAL240

10

FAL480

18 (1P), 25(2. 3P)

18

FCL

100

65

Circuit Breaker Termination Options

(Third character of catalog number)

F=No LugsL=Lugs both endsM=Lugs "ON" end onlyP=Lugs "OFF' end only

Accessories pages 6-36-6-38Optional Lugs pages 6-43. 6-44Dimensions pages 6-49, 6-50Enclosures pages 6-51-6-54

152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL24015FAL24020FAL24025FAL24030FAL24035FAL24040FAL24045FAL24050FAL24060FAL24070FAL24080FAL24090FAL24100

$406.406.406.406.

406.406.406.406.406.525.525.525.525.

FCL24015FCL24020FCL24025FCL24030FCL24035FCL24040FCL24045FCL24050FCL24060FCL24070FCL24080FCL24090FCL24100

$ 965.965.965.965.

965.965.965.965.965.

1188.1188.1188.1188.

AL50FA#14-ft4 AWGCuor

#12-#4AWGAI

AL100FA#14-«1/0 AWGCuor

#12-#1/OAWG Al

CU30FA4(1) #14-010 AWG

Cu only

(1)f»14-#3AWGCu

(1)#12-*1 AWG Al

3-pole, 480 Vac, 250 Vdc»152025303540455060708090

100

275275275275400400400400800800800900900

600600600600850850850850

14501450145017001700

FAL34015FAL34020FAL34025FAL34030FAL34035FAL34040FAL34045FAL34050FAL34060FAL34070FAL34080FAL34090FAL34100

$521.521.521.521.

521.521.521.521.521.616.616.616.616.

FCL34015FCL34020FCL34025FCL34030FCL34035FCL34040FCL34045FCL34050FCL34060FCL34070FCL34080FCL34090FCL34100

S1206.1206.1206.1206.1206.1206.1206.1206.1206.1484.1484.1484.1484.

AL50FAft 14-»4 AWGCuor

#12-#4 AWG Al

AL100FA#14-#1/0 AWG Cu or

#12-#1/OAWGAI

CU30FA4(1)#14-#10AWG

Cu only

(1)#14-#3AWGCu

(1)#12-#1 AWGAI

. FCL 2-pole circuit breaker built using 3-pole module,i FCL circuit breakers are not rated lor 250 Vdc.

6-20 DE2 DiscountSchedule

© 2003 Schneider ElectricAll Rights Reserved

9/8/03

SQUARE D

www.SquareD.comFor Hie most up-to-date information

DimensionsClass 600

I—D —

rc^I rfl 5

Figure 2 Figure 3

ra©srLr

QO, OOB

QO®, QOU, EH Circuit Breakers

B

rE

L

ArG|«-

i OFigure 4

pqI r f l W

Figure 5 QO-GFIQO-PL

QO-EPD

t jr

3 E

L 1 'I

•-A*G

Bn

G

ftjrtiki \aiw

Figure 6 Figure 7

-HA •«-

F73 E

i_

:ig

IB

i

Fig

-*•

rB

:ig

0~a

3

1of

lire 10

^iAr-pi f

ure

A

PI

crH.ire

1

1 11 I

13 Fi

- rB

17 Fi

r

i

-

1 rB E

J L

•— A-»«-G-»

BoD

fiJJlyjcjiiiFigure 8

-» A »-

mr~ SIBi ^~0iiBLff

m

Fi<

-AI

i <J

JuJ

!@

mjure 1 1

rrB

!

«-A

y

JF?

3

U

3

"Iy

uB

gure 14 Figure 15

_A_! r_A^W

I I

p

y

; i

P

r orI ~BILs_

Ifil

I !

0

a

i iO

jure 18 Figure 19

•* —

tiQ

Lo\

f7B E

!L

F'9

1E

1

B

-D— »|i-C— »

ra>oC*ip7DU.QYv Ampc

•-A-*

[olloUolil<!BB1

ure

!

F

r~i

, i

^

mig

l<?

]

Ju•re

m12

^A^0

_

I

6

"Pi

y

uft

a

Jft

~A~1an

Q

a

Iigu0-P

t— Dr-<

FD — «-C-

O

, n[

re 9LPS

3

-«*• t

b' •jit iHlgl

gure16

— A 1Hi irnIwJ

o1 1

®

IQI

1

Or

r~Ei_

Figure 20

:i' B

J

F

QOUi Ampere

— D— 1

rHaC60

- — D — M

rHaNC100

Circuit BreakerCatalog No.

Prefix

QO.QOB

QOB-VH 150 AQOB-VH 11 0-1 50 A

QO-PLQO-GFIQO-EPD

QOUQYULow Ampere

QOUHigh Ampere

MULTI 9™ C60N

MULTI9NC100

QO-PLPSPower Supply

No.Poles

12

3

2

3

1

2

3

1

2

3

1

2

3

1

2

3

4

1

2

3

4

2

Fig-No.12

3

2

3

4

5

5

6

7

8

10

11

12

13

14

15

16

17

18

19

20

9

Dimensions — Inches

A

0.75

1.50

2.25

3.0

4.50

0.75

1.50

2.25

0.75

1.50

2.25

0.75

1.50

2.25

0.71

1.42

2.13

2.84

1.06

2.13

3.19

4.25

1.45

B

3.00*

3.00*

3.00 A

5.72

5.72

4.12«

4.121

4.121

4.05 »

4.05*

4.05*

4.45

4.45

4.45

3.19

3.19

3.19

3.19

3.19

3.19

3.19

3.19

4.35

C

2.31

2.31

2.31

2.53

2.53

2.31

2.31

2.31

2.38

2.38

2.38

2.37

2.37

2.37

1.73

1.73

1.73

1.73

1.73

1.73

1.73

1.73

2.42

D

2.91

2.91

2.91

4.90

4.90

2.91

2.91

2.91

2.98

2.98

2.98

2.96

2.96

2.96

2.76

2.76

2.76

2.76

2.76

2.76

2.76

2.76

3.11

E

2.25

2.25

2.25

3.78

3.78

2.25

2.25

2.25

2.25

2.25

2.25

2.25

2.25

2.25

1.77

1.77

1.77

1.77

1.77

1.77

1.77

1.77

F

5.00T

5.00T

5.00 A

6.78

6.78

6.78

G

0.59

1.34

2.09

2.85

4.35

0.59

1.34

2.09

0.62

1.37

2.12

* 35-70 A is 3.12 in; 80-100 A 2-pole and 70-100 A 3-pole are 3.50 in.* QO-PL is 4.55 in.» 80-100 A 1-pole and 80-125 A 2-pole are 4.45 in.* 70-100 A 4.45 in.T 80-100 A 1-pole and 80-125 A 2-pole are 6.78 in.A 70-100 A is 6.78 in.

QB, QD, QG, QJ, Q4, FA, Fl, KA, Kl, LA,MA, ME and MX Circuit BreakersCircuit Breaker

Catalog No.Prefix

QB, QD,QG.QJ

FAL, FHL.FCLO

FIL, KAL,KHL. KCL, KIL

Q4L, LAL, LHL

MAL, MHL

No.Poles

2

3

1

2

3

2&3

2 & 3

28.3

Fig-No.

22

23

21

22

23

23

23

23

Dimensions — Inches

A

6.47

6.47

6.00

6.00

6.00

8.00

11.00

14.00

B

3.00

4.50

1.50

3.000

4.50

4.50

6.00

9.00

C

3.02

3.02

3.16

3.16

3.16

3.66

4.06

4.53

D

3.93

3.93

4.13

4.13

4.13

4.75

5.84

6.50

E

a

a

0.44

0.44

0.44

0.44

0.88

1.66

F

4.25

4.25

5.13

5.13

5.13

7.13

9.25

10.69

G

1.50

1.50

1.50

1.50

2.00

3.00

H

0.75

0.75

0.75

1.00

1.50

a Dimensions E are 1.59 in at ON end and 0.63 in at OFF end.0 FCL 2-pole circuit breaker dimension B is 4.50 as in Fig. 23.

-i%r

EFigure 21

r-*M

A F n A F

ILF L1 1—S- -ij- I— —

Figure 22

Ej

ftA F

IL

-. B »

i G r-*JHH(--— o — o —

C/L

PIJT— o-

y-o —t i

E

-D •)-C—«J

Figure 23

© 2003 Schneider ElectricAll Rights Reserved9/8/03 6-49

top related