flexguard fg-1525 glassbreak sensor training. flexguard how does an acoustic glassbreak work?...
Post on 11-Jan-2016
219 Views
Preview:
TRANSCRIPT
Fle
xG
uard
FG-1525 Glassbreak Sensor Training
Fle
xG
uard
How does an acoustic glassbreak work?
Glassbreak Theory Basics
Fle
xG
uard
Flex Signal
• Very low frequency sound• Results from glass vibrating upon impact• Similar to a drum head vibration
FLEX SIGNAL
PANE OF GLASS
Fle
xG
uard AUDIO SIGNAL
PANE OF GLASS
• Mid- to High-frequency sound
• Results from glass shattering
Audio Signal
Fle
xG
uard
Installation Basics
• Never exceed max range (25ft)
• Mount on opposite wall or ceiling
• Install at least 6 ft from floor (to avoid blockage by furniture,etc.)
Fle
xG
uard
Installation Basics
• Always mount the sensor in direct line of site to the glass…
• e.g….an imaginary string tied to the detector should reach all points of the glass without bending.
• Always use the Tester for every installation
Fle
xG
uard
Installation BasicsSelecting the Location
• Clear view of glass to be protected
• At least 6.5 feet above floor
• At least 3.5 feet from forced air ducts
• At least 3.5 feet from sirens or bells
• Between the window and any heavy protective window coverings
Fle
xG
uard
Installation BasicsLocations to Avoid Mounting
• A corner• On the same wall as the
protected glass• On free-standing pillars or posts• In rooms with noisy equipment
such as air compressors, bells, power equipment if the equipment will be operating while the sensor is armed
Fle
xG
uard
Introducing the FG-1525Glassbreak Detector
• FlexCore Signal Processing• 25ft maximum range• Adjustable sensitivity• No minimum range• Remote Test Mode Enable
with FG-701• Protected PCB in all models
Fle
xG
uardFlexCore Signal
Processing•Parallel multiple tasking
•Faster than sequential processing (micro)
•Extracts over 50% more data in same time
•Faster, more accurate false alarm rejection
Fle
xG
uard
FG-1515Glassbreak Detector
Same as FG-1525, except range is fixed at 15 feet
Fle
xG
uard
FGW-1525Wireless Glassbreak Detector
• Wireless-ready version of FG-1525
• Uses 9V lithium battery• Also, available as 5852
with complete 5800 transmitter
Fle
xG
uard
Installation BasicsDesign Features
DETECTOR PARTS:
1 - Wire Entry Hole
2 - DIP Switches
3 - Terminal Blocks
4 - Breakout Flash (for
cover screw)
5 - Latch
6 - Microphone
7 - Red LED
8 - Green LED
9 - Spacer Plate (Optional)
Hinged cover twists off to improve access during wiring
Fle
xG
uard
Installation BasicsMounting the Detector
Route the wires through the center wire entry port.
Fle
xG
uard
Installation BasicsWiring Connections
Wire as shown for Normally closed loop without EOL resistor.
Fle
xG
uard
Installation BasicsSensitivity Settings
MAX MED
LOW LOWEST
Sens1
Sens2
Sens1
Sens2Sens1
Sens2
Sens1
Sens2
Fle
xG
uard
Installation BasicsSensitivity Settings
• Mount the detector
• Start on Minimum sensitivity
• Test range using FG-701 simulator
• Adjust sensor sensitivity as needed
• Re-test range using FG-701 simulator
Fle
xG
uard
Installation BasicsUsing Remote Test Mode
• Set FG-701 to “Activate” and “Man”• Press “Red” button• The “buzz” signal starts Test Mode• Green LED will flash
Fle
xG
uard
Installation BasicsTesting
• Set FG-701 to “Test” and “Flex”• Position tester near the glass• Press “Red” button to prime the tester …
Fle
xG
uard
Installation BasicsTesting
• Aim FG-701 directly at detector• Strike glass with cushioned tool (Flex signal)• Tester will generate “Audio” signal• Detector’s “Red” LED will light for successful test
Fle
xG
uard
Sens1
Sens2
Latch
LED
Switch OFF ON
Latch Red LED lights for Red Alarm LED latches
5 seconds during Alarm ON at Alarm
LED LED's are disabled except LED's are always Enabled
during Power-up and Test Mode
Installation BasicsSelecting Sensor Features
Fle
xG
uard
Types of Glass Covered
• UL and ULC Listed for:
• Plate Glass
• Tempered Glass
• Laminated Glass
• Wired Glass
• Coated Glass
• Double Pane Sealed Insulated Glass
Fle
xG
uard
FG-1525Proven Performance
The Facts about the Best Performing Glassbreak Detector in the World
Fle
xG
uard
• >50,000 glassbreak events
• All glass types with wide range of size/thickness
• Acoustic environment extremes
• Multiple ranges/angles from glass
• Multiple breaking tools
FG-1525Detection Verification
Fle
xG
uard • 51,120 false alarm events
• Acoustic environment extremes
• Most common, most difficult
FG-1525False Alarm Verification
Fle
xG
uard
Specific False Alarm Tests
• Glass bottle on bottle• Glass bottle on floor• Full file cabinet drawer• Empty file cabinet drawer• Silverware in pot• Silverware on floor• 2x4 stud slapped
together• Hammer on nails• Wooden door slam• Pebbles on window• Keys on window• Coin tapped on glass• Pot dropped on floor• Pot dropped on pot
• Brass door knocker• 2x4 stud dropped on floor• Balloon pop• Plastic bag pop• Microwave door slam• Kitchen cabinet door slam• Chair dropped on floor• Metal ladder dropped• Broom dropped on floor• Shovel dropped on floor• Full cardboard box dropped• Metal alarm box closed• Dropped 1/4” plate glass• Dropped 1/8” plate glass
Fle
xG
uard
PRODUCT Position 1 Position 2
Sentrol SP3 89% 86%
FG-1525 95% 95%
HARD ROOM
No one else comes close!
FG-1525False Alarm Tested Against the
Best
Fle
xG
uard
• Hands down the choice of ADT & Brinks
• Seamless introduction and acceptance in the field
• Over 81,400 shipped to National Accounts in 2000 !
FG-1525Proven Performance
Fle
xG
uard
Reviewing the FG-1525Glassbreak Detector
• FlexCore Signal Processing• 25ft maximum range• Adjustable sensitivity• No minimum range• Remote Test Mode Enable
with FG-701• Protected PCB in all models
Fle
xG
uard
• FlexCore Processing• 8ft max range
(no min range)• Adjustable Sensitivity• Remote Test Mode
Activation• Built-in ValueGap
Magnetic Contact
Introducing the FG-1508Glassbreak Detector
Fle
xG
uard
More FlexGuard Glassbreaks…Coming Q2 2001
FG-1508: 8ft detector withmagnetic contact
FG-1525R: Round case
FG-1525F: Flush mount case,single gang
FG-1525FD: Flush mount case,double gang
FG-1525Z: Zone detector
Fle
xG
uard
Recessed ContactsStandard Models
• Mini-screwdriver• Lots of patience• 2 aspirin
Great idea!, but needs...
Fle
xG
uard
Staggered “T” Contacts
Uses regularscrewdriver!
Same great idea!, but EASY!
Fle
xG
uard
Staggered “T” Contacts
• Staggered Terminals models– 944T: 3/8” recessed– 944TSP: 3/4” switch / 3/8” magnet– 947-75T: 3/4” steel door switch– 955PST: Plunger Switch– 956RPT: Roller/ Plunger
• Packaged in Ammo Boxes
Fle
xG
uard
FG-1525 Glassbreak Sensor…The best there is !