god-a-101 - ground & first floor plans€¦ · ground & first floor plans 1/4" =...
Post on 22-Aug-2020
0 Views
Preview:
TRANSCRIPT
NURSING
STATION
6'-10" X 9'-6"
HYGIENIST
8'-10" x 11'-11"
MALE WC
5'-11" X 3'-8"
LUNCH ROOM
10'-6" X 7'-0"
DOCTOR'S
OFFICE 01
10'-6" X 13'-2"
DENTIST
OFFICE
14'-5" X 13'-5"
WAITING AREA
9'-8" X 14'-9"
JAN CLOSET
3'-9" X 4'-11"
43'-0"
[13104]
3'-11
1
4
"
[1200]
39'-0
3
4
"
[11904]
53
'-5
3
4
"
[16302]
44
'-3
3
4
"
[13503]
9'-2
1
4
"
[2798]
37'-1"
[11303]
RECEPTION
10'-6 X 11'-6"
PLANTERPLANTER
SH
EL
VE
S
MICROWAVE
JAN CLOSET
5'-7.5" X 4'-6.5"
FOYER
5'-9" X 12'-2"
FEMALE WC
5'-11" X 3'-8"
EXAMINATION
TABLE
EXAMINATION
TABLE
LOBBY
9'-8" X 6'-7"
DOCTOR'S
OFFICE 02
9'-8" X 12'-4"
RECEPTION
8'-10" X 9'-10"
LUNCH ROOM
8'-10" X 6'-5"
MICROWAVE
WAITING AREA
10'-6" X 26'-11"
TA
BL
E
TA
BL
E
TA
BL
E
CR
AD
EN
ZA
ST
OR
AG
E U
NIT
ST
OR
AG
E U
NIT
MALE WC
5'-11" X 3'-8"
FEMALE WC
5'-11" X 3'-8"
CORRIDOR
3'-9" X
10'-10"
CORRIDOR
4'-11" X
13'-2"
Extract fan in ceiling with
minimum turn over rate of
750 cubic ft. per hour.
Extract fan in ceiling with
minimum turn over rate of
750 cubic ft. per hour.
5'-11"
[1802]
24
'-4
3
4
"
[7438]
30
'-1
0"
[9400]
UP
Proposed stairs of
non-combustible
Conc. construction.
UP
1:12 RAMP UP
Proposed disabled access
ramp in compliance with
Approved Document "K"
0'-0" A.F.L 0'-0" A.F.L
LUNCH ROOM
8'-10" x 6'-7"
24'-5
"
[7442]
30
'-1
0"
[9400]
STORAGE
6'-9"x4'-7"
WAITING AREA
20'-10" X 7'-10"
RECEPTION
9'-11" x 8'-2"
DOCTOR'S
OFFICE
9'-10" x 11'-6"
DOCTOR'S
OFFICE 01
8'-10" x 15'-5"
OFFICE
9'-6" x 6'-2"
MALE WC
5'-11" X 3'-8"
FEMALE WC
5'-11" X 3'-8"
LUNCH ROOM
10'-6" X 7'-0"
MICROWAVE
MICROWAVE
NURSING
STATION
6'-5" X 11'-6"
RECEPTION
10'-6 X 11'-6"
STORAGE
6'-8"x4'-7"
CRADENZA
CRADENZA
MALE WC
5'-11" X 3'-8"
FEMALE WC
5'-11" X 3'-8"
CORRIDOR
3'-3" X 8'-8"
CORRIDOR
16'-0" X 4'-0"
WAITING AREA
27'-11" X 9'-6"
CORRIDOR
4'-2" X 9'-10"
CORRIDOR
4'-3" X 8'-0"
VESTIBULE
10'-6" X 4'-7"
43'-0"
[13104]
3'-11
1
4
"
[1200]
39'-0
3
4
"
[11904]
56
'-2
"
[17117]
44
'-3
3
4
"
[13503]
9'-2
1
4"
[2798]
37'-1"
[11303]
5'-11"
[1802]
HYGIENIST
9'-8" x 12'-2"
DENTIST
OFFICE
14'-5" X 11'-1"
2'-8
"
[815]
10
3
4"
[275]
DN
Proposed stairs of
non-combustible
Conc. construction.
9'-1" A.F.L
9'-1" A.F.L
9'-1" A.F.L
5'-3" A.F.L
LANDING
Extract fan in ceiling with
minimum turn over rate of
750 cubic ft. per hour.
Extract fan in ceiling with
minimum turn over rate of
750 cubic ft. per hour.
POROPOSED GROUND FLOOR PLAN
SCALE - 1/4" = 1'-0"
01
PROPOSED FIRST FLOOR PLAN
SCALE - 1/4" = 1'-0"
02
CLIENT:
DATE:
STATUS:
GENERAL NOTES:
DO NOT SCALE, USE FIGURED DIMENSIONS ONLY.
ALL DIMENSIONS & LEVELS IN IMPERIAL & METRIC.
ALL DIMENSIONS TO BE CHECKED ON SITE.
THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL RELEVANT
DRAWINGS & SPECIFICATIONS.
IN THE EVENT OF ANY DISCREPANCIES BETWEEN DRAWINGS
INFORM THE ARCHITECT IMMEDIATELY
© COPYRIGHT THIS DRAWING IS NOT TO BE REPRODUCED OR
DISTRIBUTED WITHOUT PERMISSION.
DRAWING NO:
DRAWING:
REV.
CHECKED BY:
SCALES:
DRAWING
DRAWN BY: DATE:
PROJECT CODE:
DESCRIPTION.REVISION DATE
LEGEND:
PROJECT
Change of use
Ventnor Gardens No.1,
Dayrells Road,
Christ Church
2016/06/05SA2016/06/05BT
DRAFT
GODSON
GROUND & FIRST FLOOR PLANS
1/4" = 1'-0"
GOD-A-101
-
N/A
N
BUILDING GROUND FLOOR AREA: 2222 SQ.FT
TOTAL BUILDING FLOOR AREA: 4348 SQ.FT
TOTAL ROOF AREA: 2509 SQ.FT
Denotes full height fire
rated type-x fire code
gypsum & metal stud
party wall
Denotes new none
combustible concrete
masonry wall construction.
Denotes existing none
combustible concrete
masonry wall construction.
Denotes new composite
none combustible concrete
masonry wall with metal
furring construction.
BUILDING FIRST FLOOR AREA: 2126 SQ.FT
NOTES:
The purpose of this application is for a change of use from a Day Care & apartment
building to a medical office rental complex consisting of 4 rental units.
All existing construction is comprised of none-combustible concrete masonry unit
envelopes & partitions & concrete floor slabs.
All new construction shall be a combination of none-combustible concrete masonry
unit block work and fire rated full height metal stud partition & gypsum board finish.
All new windows shall be 100% ventilating casement or awning style.
Offices to be air conditioned via mini-split A/C units.